createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723643147325
version7
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee4380.00
emd220000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose03-09-2024 17:00:00
tenderQueryClose31-08-2024 15:00:00
technicalBidOpen05-09-2024 15:00:00
publishedDate20-08-2024 14:01:21
publishedByPostDUDC_EE_KLR
publishedByUserKPE11980 - SRINIVAS D
bidValidityPeriod90
noOfCalls1
preBidMeetingDate26-08-2024 15:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonAjith Kumar case worker
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9731262015
tenderSupplierListNone
tenderSchedule
createdTs1723643147394
version10
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/WS/WORK_INDENT26388
titleExisting borewell for Supplying & installation of Motor Pump, Cable & other necessaries material & Laying of pipeline Laying of HDPE Pipeline, Laying of PVC Pipeline in Kolar CMC limit under Amruth Nagarothana Phase 04 Scheme
descriptionExisting borewell for Supplying & installation of Motor Pump, Cable & other necessaries material & Laying of pipeline in wno.1 to 9, 11, 13 and 15 to19 and 21 to 35 (Ward wise Rs.5.00 Lakhs Total 155.00 Lakhs) (2) Laying of HDPI Pipeline in wno.14 (Rs.5.00 Lakhs) (3) Laying of PVC Pipeline Hale Katari Gangamma gudi to railway track & Bajane house to Nagendra house in wno.12 (5.00 Lakhs) (4) Construction of Sump Kataripalya school premises in wno.20 (Rs.5.00 Lakhs) (5) Laying of Pipeline Thambihalli Nagaraj house to Gangamma gudi via Kataripaly mainroad main entertains in wno.10 (Rs.5.00 Lakhs) CMC Kolar limit under Amruth Nagarothana phase 04 Scheme
categoryWORKS
categoryTextWorks
ecv17500000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2195
locationNameDMA District Urban Development Cell Kolar
provisionalAmount17500000.0
groupOverheadTotal2676590.23
fileNumberKLR/WS/179/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17236431470000NoneNoneWater supply/sewage linesExisting borewell for Supplying & installation of Motor Pump, Cable & other necessaries material & Laying of pipeline Laying of HDPI Pipeline, Laying of PVC Pipeline in Kolar CMC limit14823409.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3782021142865Nonecode01Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. etc. complete(BWSSDB SR 2023-24, V-05, Pg no:153,Item code : 13.15.7)7.50 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00"Each42034.342034.31.0FalseNoneNoneFalseNoneFalse42034.30
3782022142865Nonecode02Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. etc. complete(BWSSDB SR 2023-24, V-05, Pg no:153,Item code : 13.20.5)20.00 HP - 135 LPM @ 350 m = 25 STG Outlet Dia - 2.00"Each83522.783522.727.0FalseNoneNoneFalseNoneFalse2255112.90
3782023142865Nonecode03Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. etc. complete (BWSSDB SR 2023-24, V-05, Pg no:153,Item code : 13.21.5) 25.00 HP - 135 LPM @ 420 m = 30 STG Outlet Dia - 2.00Each85097.5785097.571.0FalseNoneNoneFalseNoneFalse85097.570
3782024142865Nonecode04Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For: GI Pipe etc. complete.(BWSSDB SR 2023-24, V-05, Pg no:128 ,Item code : 11.2.6) Medium Duty GI pipe of 50mm diaMtr601.52601.527120.0FalseNoneNoneFalseNoneFalse4282822.40
3782025142865Nonecode05Supplying and drawing 3 core flat PVC sheathed submersible pumpcable manufactured with electrolytic grade copper with flexible copperwith low resistance conductor confirming to13:8130-1984 and virgingrade PVC insulation and powder coating extruded PVC sheathedsuitable for working voltage upto 1100 Volts as per IS-694:1990.(BESCOM SR 2023-24, V-06,Pg No:02, Item No:-2.6.3)3C x 6 mm2Mtr252.35252.3512620.0FalseNoneNoneFalseNoneFalse3184657.00
3782026142865Nonecode06Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.(BWSSDB SR 2023-24, V-5, Pg No:156, Code:13.32)Job6695.06695.029.0FalseNoneNoneFalseNoneFalse194155.00
3782027142865Nonecode07Supply, installing,testing andcommissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.(BWSSDB SR 2023-24, V-05, Pg no:155 ,Item code :13.24.3) 6 to 15 HP pumpsEach18025.018025.026.0FalseNoneNoneFalseNoneFalse468650.00
3782028142865Nonecode08Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. (BWSSDB SR 2023-24, V-05, Pg no:156 ,Item code : 13.34)Each1493.51493.525.0FalseNoneNoneFalseNoneFalse37337.50
3782029142865Nonecode09Fabricating supplying and mounting MS box made out ....SWGsuitable for floor /wall mounting, fully weather proof with provisionfor better heat dissipation, provided with hinged front cover,equipped with tamper proof locking arrangements, with suitablesize clamps with necessary cable entry pipe with gland and boxshould be finished with 7tanks treatment with powder coated paintand finally finished with approved colour etc., complete.(PWD ELE SR 2023-24, V-6, Pg No:20, Code:5.42.2)16 SWGSq CM0.440.44324000.0FalseNoneNoneFalseNoneFalse142560.00
3782030142865Nonecode10Supplying & fixing of Porcelain fuse channel with cut out onexisting wooden/panel using necessary nuts, bolts and washers.(PWD ELE SR 2023-24, V-6, Pg No:14, Code:5.7.5, )200 AEach1471.871471.8781.0FalseNoneNoneFalseNoneFalse119221.470
3782031142865Nonecode11Wiring for lighting/power circuit using one of FRLS PVC insulated1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS 694:2010(PWD ELE SR 2023-24, V-6, Pg No:05, Code:2.3.6 )10 mm2Mtr172.01172.01198.0FalseNoneNoneFalseNoneFalse34057.980
3782032142865Nonecode1216 Sqmm Aluminium Single Core/Multi Core of Grade 650/1100V (BESCOM SR 2021-22, Part :- 05 , Pg No:- 17, SL NO:-3)Mtr42.1842.18900.0FalseNoneNoneFalseNoneFalse37962.00
3782033142865Nonecode13Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments. (BWSSDB 2023-24 SR RATE Pg no:154,code: 13.25.1).Size 50mmEach1287.51287.526.0FalseNoneNoneFalseNoneFalse33475.00
3782034142865Nonecode14Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for: (BWSSDB SR 2023-24 Pg no:129,code:- 11.7.6).For 50 mm dia GI elbowEach275.01275.0151.0FalseNoneNoneFalseNoneFalse14025.510
3782035142865Nonecode15Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments(BWSSDB SR 2023-24 Vol-5,P. No:154, I.No:13.24.3)Size 80mmEach1699.51699.52.0FalseNoneNoneFalseNoneFalse3399.00
3782036142865Nonecode16Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments(BWSSDB SR 2023-24 Vol-5,P. No:154, I.No:13.24.1)Size 50mmEach1287.51287.546.0FalseNoneNoneFalseNoneFalse59225.00
3782037142865Nonecode17Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments(BWSSDB SR 2023-24 Vol-5,P. No:154, I.No:13.24.2)Size 65mmEach1493.51493.512.0FalseNoneNoneFalseNoneFalse17922.00
3782038142865Nonecode18Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments if any.(BWSSDB SR 2023-24 Vol-5,P. No:129 , I.No:11.6.6)For 50 mm dia GI collar:Each275.01275.011033.0FalseNoneNoneFalseNoneFalse284085.330
3782039142865Nonecode19Cutting Asphalt /Concrete road surface using machine cutter for leakage pit with earth work excavation in all classifications of soil including all lead and lifts bailing out water with pumps including barricading, danger lighting etc., as per requirement and disposing of the excavated stuff as directed. After attending the leak, refilling the trench for 30 cm depth quarry dust above and around pipelines and balance with available earth in layers not exceeding 20 cms in depth, compacting Each deposited layer by ramming including watering and consolidation by mechanical means approved by Engineer Incharge. (Work to be carried out as per leak repair manual and the rate includes hire charges of dewatering Pump, tractor, Jeep with all kinds of Labour in a Complete manner).(BWSSDB SR 2023-24, V-5,Pg No:- 48, Item No:-3.3)Cum1191.711191.71254.1FalseNoneNoneFalseNoneFalse302813.5110
3782040142865Nonecode20Earth work excavation for pipelines/cables by Manual means upto 600mm trench width, as per drawing and technical specifications, includingsetting out, shoring, strutting, barricading, caution lights, removal ofstumps and other deleterious matter, including dressing of excavatedsurfaces, disposing off or leveling the excavated earth or sorting& stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20cm in depth, consolidatingeach deposited layer by ramming and watering and lift upto 1.5 mincluding cost of labour, tools, usage& other appurtenances requiredto complete the work.(PWD SR 2023-24, V-1, Pg No: 6,Item Code:1.6.1)In all kinds of soils. Depth upto 1.50mCum498.52498.521605.2625FalseNoneNoneFalseNoneFalse800255.46150
3782041142865Nonecode21Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.(BWSSDB SR 2023-24, V-5, Pg No:113, Item code:10.1.4) PVC PIPES 63MM DIA, 6KG/SQCM & CLASS3Mtr165.83165.831450.0FalseNoneNoneFalseNoneFalse240453.50
3782042142865Nonecode22Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.(BWSSDB SR 2023-24, V-5, Pg No:113, Item code:10.1.6) PVC pipes 90mm dia., 6 kg/sqcm & class 5Mtr302.82302.82745.0FalseNoneNoneFalseNoneFalse225600.90
3782043142865Nonecode23Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0(BWSSDB SR 2023-24, V-05, Pg No:95 ,Item Code:9.1.1) HDPE Grade PE80-PN6.0, 63mm diaMtr194.67194.67198.0FalseNoneNoneFalseNoneFalse38544.660
3782044142865Nonecode24Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0(BWSSDB SR 2023-24, V-05, Pg No:95 ,Item Code:9.1.2) HDPE Grade PE80-PN6.0, 75mm diaMtr252.35252.351108.0FalseNoneNoneFalseNoneFalse279603.80
3782045142865Nonecode25Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0(BWSSDB SR 2023-24, V-05, Pg No:95 ,Item Code:9.1.3) HDPE Grade PE80-PN6.0, 90mm diaMtr330.63330.63390.0FalseNoneNoneFalseNoneFalse128945.70
3782046142865Nonecode26Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 160MM DIA(BWSSDB SR 2023-24, V-05, Pg No:95 ,Item Code:9.1.7)Mtr987.77987.77799.0FalseNoneNoneFalseNoneFalse789228.230
3782047142865Nonecode27Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. (PWD SR 2023-24, V-II, Pg No:-26, Item Code:-4.17)Cum2635.772635.7717.55FalseNoneNoneFalseNoneFalse46257.76350
3782048142865Nonecode28Providing and laying in position plain cement concrete for levelling course for all works in foundation. Thegranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) (PWD SR 2023-24, V-1, Pg No:-15, Item Code:2.1.6) Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregatesCum6430.296430.2999.9FalseNoneNoneFalseNoneFalse642385.9710
3782049142865Nonecode29Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cm in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5m. Including cost of all labour complete as per specifications (PWD SR 2023-24, V-II, Pg No:-26, Item Code:-4.17)Cum164.8164.8203.4FalseNoneNoneFalseNoneFalse33520.320
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17236431480000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17236431480000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17236431480000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17236431480000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17236431480000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17238742510000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weight age of 10% per year to bring them to the price level of the 2024-25.None
17238742620000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17238742950000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bid.None
17238743030000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17238743330000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17238743440000NoneNoneELIGIBILITYAs per Karnataka State Government order No.LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No.PW/134/BMS/2007 Dated 27-07-2007, a sum amounting to 1% of the bill amount will be deducted towards Construction Labour Welfare fund.None
17238743530000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reason or what so ever.None
17238744070000NoneNoneELIGIBILITYThe Bidder should quote Item wise excluding GST, GST will be paid separately by the DepartmentNone
17238744280000NoneNoneELIGIBILITYAll other terms & conditions as per the Tender Document.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneSatisfactory completed, at least one similar any type of Water supply work of value not less than Rs. 87.50 Lakhs as prime contractor in last five years i.e., 2019-20 to 2023-24Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year (for a continuous period of 12 months) the following minimum quantities of work Supplying and installing of Pump Set 23 no GI pipes 5696 mtr PVC Insulated cable 10096 mtr Earth work Excavation 1284 Cum PVC Pipes 1756 Mtr HDPE Pipe 1996 Mtr in the last five years i.e., 2019-20 to 2023-24Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNonePWD Registration certificate Class-3 or aboveCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneAssessed available tender capacityCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed available tender capacity
NoneNoneNoneNoneAchieved in at least two financial years a minimum annual financial turnover of Rs.350.00 Lakhs. (Turnover certificate from CA with valid UDIN No. to be furnished along with necessary documents) in last five years i.e., 2019-20 to 2023-24Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and or availability of credit facilities of not less than Rs.44.47 Lakhs (Unconditional Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc).Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
PWD Registration certifictaeTrueTechnical Bid
Work done certificateTrueTechnical Bid
LOC BANKER CERTIFICATETrueTechnical Bid
tender capacityTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
Water supply/sewage linesKolarKolarKolarKOLARCITY MUNIICPAL COUNCIL KOLARNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1724134373000
version0
createdDateNone
modifiedDateNone
blockNumberS-8 Room, Deputy commissioner office, kumbarhalli, tamaka, kolar district kolar
streetNone
citykolar
stateKarnataka
pin563101
tenderRecallDTONone