createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723459700998
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd657100.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose18-09-2024 16:00:00
tenderQueryClose18-09-2024 15:30:00
technicalBidOpen19-09-2024 16:30:00
publishedDate20-08-2024 11:48:54
publishedByPostPWD_EE_SPL_DIV_RMG
publishedByUserKPE15665 - MAHADEVAPPA H M
bidValidityPeriod90
noOfCalls1
preBidMeetingDate02-09-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonMAHADEVAPPA H M
splitEmdRequiredYnTrue
emdBankGuarantee557100.00
emdCash100000.00
bgValidityPeriod135
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08012345678
mobileNumber9945231914
tenderSupplierListNone
tenderSchedule
createdTs1723459701039
version7
createdDateNone
modifiedDateNone
tenderNumberPWD/2024-25/BD/WORK_INDENT4848
titleCONSTRUCTION OF GOVERNAMENT INDUSTRIAL TRAINING INSTITUTE ( I T I ) 5 TRADES COLLEGE AT HAROHALLI IN KANAKAPURA TALUK, RAMANAGARA DIST.
descriptionCONSTRUCTION
categoryWORKS
categoryTextWorks
ecv43802758.62
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location1669
locationNamePWD Special Division Office Ramanagara
provisionalAmount44000000.0
groupOverheadTotal0.0
fileNumberAEE/PWD/KKP/2023-24/BUILDING/ITI
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17234597010001NoneNoneBuildingsCONSTRUCTION OF GOVERNAMENT INDUSTRIAL TRAINING INSTITUTE ( I T I ) 5 TRADES COLLEGE AT HAROHALLI IN KANAKAPURA TALUK, RAMANAGARA DIST39201086.88
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3758123141234None2.5 (ii) AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer By Mechanical Means using Dozer (P. No - 9, I. No - 2.5 (ii) A, Vol-3) 100 Sqm477.65477.6580.98FalseNoneNoneFalseNoneFalse38680.0970
3758124141234None1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (P. No - 8, I. No - 1.12, Vol-1 - Common S R)Cum115.46115.461214.4FalseNoneNoneFalseNoneFalse140214.6240
3758125141234None1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m (P. No - 8, I. No - 1.14.1, S R 2023-24, Vol-1 - Common S R)Cum123.97123.971723.13FalseNoneNoneFalseNoneFalse213616.42610
3758126141234None1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m, In ordinary/soft rock without blasting upto 1.5 m depth(P. No - 8, I. No - 1.15.1, S R 2023-24, Vol-1 - Common S R)Cum441.19441.19191.47FalseNoneNoneFalseNoneFalse84474.64930
3758127141234None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (P. No - 7, I. No - 1.9, S R 2023-24, Vol-1 - Common S R) Cum323.3323.31723.13FalseNoneNoneFalseNoneFalse557087.9290
3758128141234None1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. (P. No - 7, I. No - 1.8, S R 2023-24, Vol-1 - Common S R) Cum576.1576.1162.14FalseNoneNoneFalseNoneFalse93408.8540
3758129141234None4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. (P. No - 5, I. No - 4.1, S R 2023-24, Vol-2 - For Buildings)Sqm143.42143.421857.36FalseNoneNoneFalseNoneFalse266382.57120
3758130141234None2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labor, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (P. No - 15, I. No - 2.1.2, S R 2023-24, Vol-1 - Common S R)Cum6884.036884.03337.17FalseNoneNoneFalseNoneFalse2321088.39510
3758131141234None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (P. No - 9, I. No - 5.4, S R 2023-24, Vol-2 - For Buildings)Cum7765.197765.19104.58FalseNoneNoneFalseNoneFalse812083.57020
3758132141234None2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P. No - 15, I. No - 2.2.3, S R 2023-24, Vol-1 - Common S R)Cum8316.848316.84371.33FalseNoneNoneFalseNoneFalse3088292.19720
3758133141234None2.3.2Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P. No - 16, I. No - 2.3.2, S R 2023-24, Vol-1 - Common S R)Cum13388.8513388.859.26FalseNoneNoneFalseNoneFalse123980.7510
3758134141234None2.3.2Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P. No - 16, I. No - 2.3.2, S R 2023-24, Vol-1 - Common S R)Cum11813.6911813.6962.84FalseNoneNoneFalseNoneFalse742372.27960
3758135141234None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(P. No - 16, I. No - 2.5.2, S R 2023-24, Vol-1 - Common S R)Cum14138.8714138.8744.99FalseNoneNoneFalseNoneFalse636107.76130
3758136141234None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(P. No - 16, I. No - 2.5.2, S R 2023-24, Vol-1 - Common S R)Cum13307.1713307.1794.06FalseNoneNoneFalseNoneFalse1251672.41020
3758137141234None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(P. No - 16, I. No - 2.5.2, S R 2023-24, Vol-1 - Common S R)Cum12475.4712475.47291.69FalseNoneNoneFalseNoneFalse3638969.84430
3758138141234None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(P. No - 16, I. No - 2.5.2, S R 2023-24, Vol-1 - Common S R)Cum12059.6212059.628.02FalseNoneNoneFalseNoneFalse96718.15240
3758139141234None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (P. No - 18, I. No - 2.11, S R 2023-24, Vol-1 - Common S R)Tonne108726.04108726.0485.72FalseNoneNoneFalseNoneFalse9319996.14880
3758140141234None6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P. No - 17, I. No - 6.32, S R 2023-24, Vol-2 - For Buildings)Sqm1592.171592.171811.45FalseNoneNoneFalseNoneFalse2884136.34650
3758141141234None6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P. No - 17, I. No - 6.34, S R 2023-24, Vol-2 - For Buildings)Sqm1341.81341.8436.06FalseNoneNoneFalseNoneFalse585105.3080
3758142141234None12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (P. No - 100, I. No - 12.13.1, S R 2023-24, Vol-2 - For Buildings)Cum120099.75120099.752.01FalseNoneNoneFalseNoneFalse241400.49750
3758143141234None12.11Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (P. No - 99, I. No - 12.11, S R 2023-24, Vol-2 - For Buildings)Cum167815.14167815.140.15FalseNoneNoneFalseNoneFalse25172.2710
3758144141234None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) (P. No - 100, I. No - 12.15, S R 2023-24, Vol-2 - For Buildings)Sqm9047.449047.444.5FalseNoneNoneFalseNoneFalse40713.480
3758145141234None12.57.1Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick Both side teak (P. No - 105, I. No - 12.57.1, S R 2023-24, Vol-2 - For Buildings)Sqm4913.864913.8669.72FalseNoneNoneFalseNoneFalse342594.31920
3758146141234None11.30.1Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P. No - 85, I. No - 11.30.1, S R 2023-24, Vol-2 - For Buildings)Sqm1108.441108.4410.3FalseNoneNoneFalseNoneFalse11416.9320
3758147141234None12.96Providing and fixing Fibre Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm X 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibre glass fromm all sides. M S stay shall be provided at the bottom to steady the frame. (P. No - 112, I. No - 12.96, S R 2023-24 Vol-2 - For Buildings )m781.5781.566.3FalseNoneNoneFalseNoneFalse51813.450
3758148141234None12.97.1Providing and fixing to Existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and maufacture, made with fire - resistant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP lamonate for panels confirming to IS; 14856 including fixing to frames. (P. No - 112, I. No - 12.97.1, S R 2023-24 Vol-2 - For Buildings)Sqm3894.143894.1424.57FalseNoneNoneFalseNoneFalse95679.01980
3758149141234None12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (P. No - 104, I. No - 12.51, S R 2023-24 Vol-2 - For Buildings)No1234.851234.8528.0FalseNoneNoneFalseNoneFalse34575.80
3758150141234None11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (P. No - 86, I. No - 11.34A, S R 2023-24, Vol-2 - For Buildings)Kgs204.19204.194858.56FalseNoneNoneFalseNoneFalse992069.36640
3758151141234None12.87Providing and fixing of 2.5 track x 2 -panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm Windows shall be provided with 5mm plain float glass standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8-2.0mm. Maximum possible size 1519mmx1519mm (The cost is inclusive of all fixtures and separate charges for minor T and Ps shall not be made (P. No - 109 I. No-12.87 S R 2023-24,Vol-2 For Buildings)Sqm7962.097962.09215.1FalseNoneNoneFalseNoneFalse1712645.5590
3758152141234None12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P. No - 109 I. No 12.85 S R 202324, Vol-2 For Buildings)Sqm6950.876950.8716.26FalseNoneNoneFalseNoneFalse113021.14620
3758153141234None12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size- 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P. No - 111, I. No - 12.92, S R 2023-24, Vol-2 - For Buildings)Sqm7590.177590.173.78FalseNoneNoneFalseNoneFalse28690.84260
3758154141234None11.6.1Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P. No - 78, I. No - 11.6.1, S R 2023-24, Vol-2 - For Buildings)Sqm3200.153200.1525.65FalseNoneNoneFalseNoneFalse82083.84750
3758155141234None8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P. No - 43, I. No - 8.10, S R 2023-24, Vol-2 - For Buildings)Sqm256.45256.451787.21FalseNoneNoneFalseNoneFalse458330.00450
3758156141234None8.1.2Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P. No - 41, I. No - 8.1.2, S R 2023-24, Vol-2 - For Buildings)Sqm292.91292.913596.98FalseNoneNoneFalseNoneFalse1053591.41180
3758157141234None8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P. No - 41, I. No - 8.2.2, S R 2023-24, Vol-2 - For Buildings)Sqm339.1339.12585.7FalseNoneNoneFalseNoneFalse876810.870
3758158141234None9.31Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (P. No - 64, I. No - 9.31, S R 2023-24, Vol-2-For Buildings)Sqm2534.112534.11489.19FalseNoneNoneFalseNoneFalse1239661.27090
3758159141234None10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (P. No - 69, I. No - 10.2, S R 2023-24, Vol-2-For Buildings)m398.65398.65503.21FalseNoneNoneFalseNoneFalse200604.66650
3758160141234None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (P. No - 60, I. No - 9.12.2, S R 2023-24, Vol-2-For Buildings)Sqm1391.631391.63412.49FalseNoneNoneFalseNoneFalse574033.45870
3758161141234None9.4Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge (P. No - 59, I. No - 9.4, S R 2023-24, Vol-1 - Common S R)Cum8101.868101.8668.0FalseNoneNoneFalseNoneFalse550926.480
3758162141234None9.3.1Providing Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement :3 coarse sand), finished with a floating coat of neat cement. 18mm thick (P. No - 59, I. No - 9.3.1, S R 2023-24, Vol-1 - Common S R) Sqm585.82585.8259.52FalseNoneNoneFalseNoneFalse34868.00640
3758163141234None9.5Extra for making chequers of approved pattern on 1:2:4 cement concrete floors, steps, landing, pavements etc. (P. No - 59, I. No - 9.5, S R 2023-24, Vol-1 - Common S R)Sqm66.8566.85679.95FalseNoneNoneFalseNoneFalse45454.65750
3758164141234None9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.(P. No - 60, I. No - 9.11, S R 2023-24, Vol-2-For Buildings)Sqm1080.491080.4989.99FalseNoneNoneFalseNoneFalse97233.29510
3758165141234None9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (P. No - 65, I. No - 9.39, S R 2023-24, Vol-2-For Buildings)Sqm1761.111761.11295.3FalseNoneNoneFalseNoneFalse520055.7830
3758166141234None9.40Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. (P. No - 65, I. No - 9.40, S R 2023-24, Vol-2-For Buildings)Sqm1132.751132.7515.0FalseNoneNoneFalseNoneFalse16991.250
3758167141234None11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P. No - 85, I. No - 11.28, S R 2023-24, Vol-2-For Buildings)Kg686.7686.7319.0FalseNoneNoneFalseNoneFalse219057.30
3758168141234None7.1.1Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m² (P. No - 21, I. No - 7.1.1, S R 2023-24, Vol-2-For Buildings)Sqm1068.341068.3472.98FalseNoneNoneFalseNoneFalse77967.45320
3758169141234None11.16.1Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P. No - 82, I. No - 11.16.1, S R 2023-24, Vol-2-For Buildings)Kgs165.29165.29437.76FalseNoneNoneFalseNoneFalse72357.35040
3758170141234None2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (P. No - 15, I. No - 2.1.4, S R 2023-24, Vol-1 - Common S R)Cum7556.147556.1438.77FalseNoneNoneFalseNoneFalse292951.54780
3758171141234None8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (P. No - 50, I. No - 8.51, S R 2023-24, Vol-2-For Buildings)Sqm121.54121.545384.19FalseNoneNoneFalseNoneFalse654394.45260
3758172141234None8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P. No - 48, I. No - 8.39, S R 2023-24, Vol-2-For Buildings)Sqm154.36154.365384.19FalseNoneNoneFalseNoneFalse831103.56840
3758173141234None8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P. No - 46, I. No - 8.32, S R 2023-24, Vol-2-For Buildings)Sqm189.6189.62585.7FalseNoneNoneFalseNoneFalse490248.720
3758174141234None8.33.2Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P. No - 46, I. No - 8.33.2, S R 2023-24, Vol-2-For Buildings)Sqm167.73167.73222.18FalseNoneNoneFalseNoneFalse37266.25140
3758175141234None8.33.3Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P. No - 47, I. No - 8.33.3, S R 2023-24, Vol-2-For Buildings)Sqm168.94168.94241.66FalseNoneNoneFalseNoneFalse40826.04040
3758176141234None12.76.2Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 200x10mm (P. No - 107, I. No - 12.76.2, S R 2023-24, Vol-2-For Buildings)Nos425.39425.3966.0FalseNoneNoneFalseNoneFalse28075.740
3758177141234None12.79.1Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm (P. No - 108, I. No - 12.79.1, S R 2023-24, Vol-2-For Buildings)Nos302.63302.6372.0FalseNoneNoneFalseNoneFalse21789.360
3758178141234None12.74.1Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm (P. No - 107, I. No - 12.74.1, S R 2023-24, Vol-2-For Buildings)No123.97123.97144.0FalseNoneNoneFalseNoneFalse17851.680
3758179141234None12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (P. No - 105, I. No - 12.58, S R 2023-24, Vol-2-For Buildings)No145.85145.8536.0FalseNoneNoneFalseNoneFalse5250.60
3758180141234None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (P. No - 105, I. No - 12.60, S R 2023-24, Vol-2-For Buildings)No1278.61278.628.0FalseNoneNoneFalseNoneFalse35800.80
3758181141234None8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment (P. No - 43, I. No - 8.16.1, S R 2023-24, Vol-2-For Buildings)m41.3241.321000.0FalseNoneNoneFalseNoneFalse41320.00
17234597010001NoneNoneBuildingsCONSTRUCTION OF GOVERNAMENT INDUSTRIAL TRAINING INSTITUTE ( I T I ) 5 TRADES COLLEGE AT HAROHALLI IN KANAKAPURA TALUK, RAMANAGARA DIST (WATER SUPPLY AND SANITARY WORKS)898789.53
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3758182141235None1.17.1Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m (P. No - 10, I. No - 1.17.1, S R 2023-24, Vol-1 - Common S R)Cum318.43318.43138.71FalseNoneNoneFalseNoneFalse44169.42530
3758183141235None1.10Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications (P. No - 7, I. No - 1.10, S R 2023-24, Vol-1 - Common S R)Cum194.46194.46113.4FalseNoneNoneFalseNoneFalse22051.7640
3758184141235None16.62.2Providing to work spot rolling, lowering and placing in position RCC perforated rings in the already excavated pit including loading and unloading at both the destinations with all lead and lift with appurtenances., complete. 1200 mmx1250 mm (P. No - 208, I. No - 16.62.2, S R 2023-24, Vol-5-For BWSSB)Each11599.7811599.783.0FalseNoneNoneFalseNoneFalse34799.340
3758185141235None16.61.2Supply and fixing of SFRC machinhole cover (Medium Duty) made as per IS to suit existing damaged machinhole cover after removing the debries from inside and outside the existing machinhole etc. with all lead and lifts. Heavy Duty (P. No - 208, I. No - 16.61.2, S R 2023-24, Vol-5-For BWSSB)Each1498.581498.583.0FalseNoneNoneFalseNoneFalse4495.740
3758186141235None10.1.5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 75mm dia., 6 kg/sqcm & class 3 (P. No - 113, I. No - 10.1.5, S R 2023-24, Vol-5-For BWSSB)m267.38267.3850.0FalseNoneNoneFalseNoneFalse13369.00
3758187141235None10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 110mm dia., 6 kg/sqcm & class 3 (P. No - 113, I. No - 10.1.7, S R 2023-24, Vol-5-For BWSSB)m499.52499.5280.0FalseNoneNoneFalseNoneFalse39961.60
3758188141235None10.1.9Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 160mm dia., 6 kg/sqcm & class 3 (P. No - 113, I. No - 10.1.9, S R 2023-24, Vol-5-For BWSSB)m751.11751.11150.0FalseNoneNoneFalseNoneFalse112666.50
3758189141235None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter (P. No - 125, I. No - 13.48, S R 2023-24, Vol-2 - For Buildings)m353.68353.68100.0FalseNoneNoneFalseNoneFalse35368.00
3758190141235None13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes (P. No - 122, I. No - 13.32.2, S R 2023-24, Vol-2 - For Buildings)m460.63460.63120.0FalseNoneNoneFalseNoneFalse55275.60
3758191141235None13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes (P. No - 122, I. No - 13.33.3, S R 2023-24, Vol-2 - For Buildings)m359.76359.76100.0FalseNoneNoneFalseNoneFalse35976.00
3758192141235None13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes (P. No - 122, I. No - 13.33.5, S R 2023-24, Vol-2 - For Buildings)m579.75579.75100.0FalseNoneNoneFalseNoneFalse57975.00
3758193141235None13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (P. No - 123, I. No - 13.34, S R 2023-24, Vol-2 - For Buildings)Ltr10.9410.944000.0FalseNoneNoneFalseNoneFalse43760.00
3758194141235None13.54Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500X700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :With common burnt clay (non modular) bricks of class designation 3.5 (P. No - 126, I. No - 13.54, S R 2023-24, Vol-2 - For Buildings)No7630.287630.2810.0FalseNoneNoneFalseNoneFalse76302.80
3758195141235None14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (P. No - 131, I. No - 14.1.1, S R 2023-24, Vol-2-For Buildings)Each5936.015936.014.0FalseNoneNoneFalseNoneFalse23744.040
3758196141235None14.5.1Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern (P. No - 132, I. No - 14.5.1, S R 2023-24, Vol-2-For Buildings)Each10503.510503.56.0FalseNoneNoneFalseNoneFalse63021.00
3758197141235None14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (P. No - 131, I. No - 14.3.1, S R 2023-24, Vol-2-For Buildings)Each7264.457264.4511.0FalseNoneNoneFalseNoneFalse79908.950
3758198141235None14.7AProviding and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (P. No - 133, I. No - 14.7A, S R 2023-24, Vol-2-For Buildings)Each5008.665008.6612.0FalseNoneNoneFalseNoneFalse60103.920
3758199141235None14.8Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. (P. No - 133, I. No - 14.8, S R 2023-24, Vol-2-For Buildings)Each1729.511729.5112.0FalseNoneNoneFalseNoneFalse20754.120
3758200141235None13.22.1Providing and fixing PTMT grating of approved quality and colour. 100 mm nominal dia (P. No - 120, I. No - 13.22.1.1, S R 2023-24, Vol-2-For Buildings)Each49.8349.8335.0FalseNoneNoneFalseNoneFalse1744.050
3758201141235None14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia (P. No - 136, I. No - 14.28.2.2, S R 2023-24, Vol-2-For Buildings)Each111.82111.8222.0FalseNoneNoneFalseNoneFalse2460.040
3758202141235None14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (P. No - 136, I. No - 14.31, S R 2023-24, Vol-2-For Buildings)Each1482.81482.812.0FalseNoneNoneFalseNoneFalse17793.60
3758203141235None13.8.2.1Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore (P. No - 118, I. No - 13.8.2.1, S R 2023-24, Vol-2-For Buildings)No110.6110.635.0FalseNoneNoneFalseNoneFalse3871.00
3758204141235None13.12Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 (P. No - 119, I. No - 13.12, S R 2023-24, Vol-2-For Buildings)No771.8771.815.0FalseNoneNoneFalseNoneFalse11577.00
3758205141235None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (P. No - 119, I. No - 13.16, S R 2023-24, Vol-2-For Buildings)No753.55753.5533.0FalseNoneNoneFalseNoneFalse24867.150
3758206141235None13.20.2Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms (P. No - 120, I. No - 13.20.2, S R 2023-24, Vol-2-For Buildings)No381.64381.6412.0FalseNoneNoneFalseNoneFalse4579.680
3758207141235None13.21.1Providing and fixing PTMT, push cock of approved quality and colour. 15 mm nominal bore, 98 mm long, weighing not less than 75 gms (P. No - 120, I. No - 13.21.1, S R 2023-24, Vol-2-For Buildings)No155.57155.5710.0FalseNoneNoneFalseNoneFalse1555.70
3758208141235None13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore (P. No - 117, I. No - 13.5.3, S R 2023-24, Vol-2-For Buildings)No403.51403.518.0FalseNoneNoneFalseNoneFalse3228.080
3758209141235None13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms (P. No - 121, I. No - 13.25, S R 2023-24, Vol-2-For Buildings)No177.45177.4511.0FalseNoneNoneFalseNoneFalse1951.950
3758210141235None13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. (P. No - 121, I. No - 13.26, S R 2023-24, Vol-2-For Buildings)No121.54121.5412.0FalseNoneNoneFalseNoneFalse1458.480
17234597010001NoneNoneBuildingsCONSTRUCTION OF GOVERNAMENT INDUSTRIAL TRAINING INSTITUTE ( I T I ) 5 TRADES COLLEGE AT HAROHALLI IN KANAKAPURA TALUK, RAMANAGARA DIST(BORE WELL WORKS)354203.15
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3758211141236None12.4Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. (P. No - 140, I. No - 12.4, S R 2023-24, Vol-5-For BWSSB)Each6427.046427.041.0FalseNoneNoneFalseNoneFalse6427.040
3758212141236None12.1.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 0 to 50 Mtrs (P. No - 139, I. No - 12.1.1, S R 2023-24, Vol-5-For BWSSB)m449.7449.750.0FalseNoneNoneFalseNoneFalse22485.00
3758213141236None12.1.2Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 50 to 100 Mtrs (P. No - 139, I. No - 12.1.2, S R 2023-24, Vol-5-For BWSSB)m563.95563.9550.0FalseNoneNoneFalseNoneFalse28197.50
3758214141236None12.1.3Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 100 to 150 Mtrs (P. No - 139, I. No - 12.1.3, S R 2023-24, Vol-5-For BWSSB)m599.19599.1950.0FalseNoneNoneFalseNoneFalse29959.50
3758215141236None12.1.4Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 150 to 200 Mtrs (P. No - 139, I. No - 12.1.4, S R 2023-24, Vol-5-For BWSSB)m695.21695.2150.0FalseNoneNoneFalseNoneFalse34760.50
3758216141236None12.1.5Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 200 to 250 Mtrs (P. No - 139, I. No - 12.1.5, S R 2023-24, Vol-5-For BWSSB)m815.53815.5350.0FalseNoneNoneFalseNoneFalse40776.50
3758217141236None12.32Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty (P. No - 143, I. No - 12.32, S R 2023-24, Vol-5-For BWSSB)m2349.372349.3720.0FalseNoneNoneFalseNoneFalse46987.40
3758218141236None12.34Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge (P. No - 143, I. No - 12.34, S R 2023-24No199.33199.331.0FalseNoneNoneFalseNoneFalse199.330
3758219141236None13.40.5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 5 HP, size 50x40 Head 46M, Discharge 174 LPM (P. No - 157, I. No - 13.40.5, S R 2023-24, Vol-5-For BWSSB)No32107.2232107.221.0FalseNoneNoneFalseNoneFalse32107.220
3758220141236None13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (P. No - 156, I. No - 13.32, S R 2023-24, Vol-5-For BWSSB)Job7900.17900.11.0FalseNoneNoneFalseNoneFalse7900.10
3758221141236None13.22.4Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x6 m2 (P. No - 154, I. No - 13.22.4, S R 2023-24, Vol-5-For BWSSB)m224.85224.85200.0FalseNoneNoneFalseNoneFalse44970.00
3758222141236None13.23.3Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter 6 to 15 HP pumps (P. No - 154, I. No - 13.23.3, S R 2023-24, Vol-5-For BWSSB)No19324.8619324.861.0FalseNoneNoneFalseNoneFalse19324.860
3758223141236None13.25.1Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm (P. No - 154, I. No - 13.25.1, S R 2023-24, Vol-5-For BWSSB)No1519.251519.252.0FalseNoneNoneFalseNoneFalse3038.50
3758224141236None13.27.1Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover (P. No - 155, I. No - 13.27.1, S R 2023-24, Vol-5-For BWSSB)Each3706.973706.9710.0FalseNoneNoneFalseNoneFalse37069.70
17234597010001NoneNoneBuildingsCONSTRUCTION OF GOVERNAMENT INDUSTRIAL TRAINING INSTITUTE ( I T I ) 5 TRADES COLLEGE AT HAROHALLI IN KANAKAPURA TALUK, RAMANAGARA DIST.(SUMP TANK, SEPTIK TANK & SOAK PIT)647786.63
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3758225141237None1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m (P. No - 8, I. No - 1.14.1, S R 2023-24, Vol-1 - Common S R)Cum123.97123.97161.26FalseNoneNoneFalseNoneFalse19991.40220
3758226141237None2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (P. No - 15, I. No - 2.1.2, S R 2023-24, Vol-1 - Common S R)Cum6884.036884.036.32FalseNoneNoneFalseNoneFalse43507.06960
3758227141237None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P. No - 15, I. No - 2.2.1, S R 2023-24, Vol-1 - Common S R)Cum8012.158012.1510.3FalseNoneNoneFalseNoneFalse82525.1450
3758228141237None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P. No - 15, I. No - 2.2.1, S R 2023-24, Vol-1 - Common S R)Cum8405.348405.3414.24FalseNoneNoneFalseNoneFalse119692.04160
3758229141237None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P. No - 15, I. No - 2.2.1, S R 2023-24, Vol-1 - Common S R)Cum11461.8311461.836.83FalseNoneNoneFalseNoneFalse78284.29890
3758230141237None16.62.2Providing to work spot rolling, lowering and placing in position RCC perforated rings in the already excavated pit including loading and unloading at both the destinations with all lead and lift with appurtenances., complete. 1200 mmx1250 mm (P. No - 208, I. No - 16.62.2, S R 2023-24, Vol-5-For BWSSB)Each11599.7811599.783.0FalseNoneNoneFalseNoneFalse34799.340
3758231141237None16.61.2Supply and fixing of SFRC machinhole cover (Medium Duty) made as per IS to suit existing damaged machinhole cover after removing the debries from inside and outside the existing machinhole etc. with all lead and lifts. Heavy Duty (P. No - 208, I. No - 16.61.2, S R 2023-24, Vol-5-For BWSSB)Each1498.591498.591.0FalseNoneNoneFalseNoneFalse1498.590
3758232141237None8.5.1Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P. No - 42, I. No - 8.5.1, S R 2023-24, Vol-2 - For Buildings)Sqm444.84444.84263.28FalseNoneNoneFalseNoneFalse117117.47520
3758233141237None8.12Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge (P. No - 43, I. No - 8.12, S R 2023-24, Vol-2 - For Buildings)Sqm77.7977.79263.28FalseNoneNoneFalseNoneFalse20480.55120
3758234141237None2.11(a)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (P. No - 18, I. No - 2.11, S R 2023-24, Vol-1 - Common S R)Tonne108726.04108726.040.68FalseNoneNoneFalseNoneFalse73933.70720
3758235141237None13.40.2Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 50x40 Head 22M, Discharge 186 LPM (P. No - 157, I. No - 13.40.2, S R 2023-24, Vol-5-For BWSSB)No20653.2920653.291.0FalseNoneNoneFalseNoneFalse20653.290
3758236141237None16.15.1Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm anddown size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame(P. No - 192, I. No - 16.15.1, S R 2023-24, Vol-5 - For BWSSB)Each35303.7235303.721.0FalseNoneNoneFalseNoneFalse35303.720
17234597010001NoneNoneBuildingsEstimate for Providing Electrification to Proposed Govt. ITI Building at Harohally in Ramangara Dist IPART-A)2110561.66
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3758237141238None1.2.1Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick m71.9871.981200.0FalseNoneNoneFalseNoneFalse86376.00
3758238141238None1.2.2Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick m82.682.6800.0FalseNoneNoneFalseNoneFalse66080.00
3758239141238None1.3.2Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick m94.494.41000.0FalseNoneNoneFalseNoneFalse94400.00
3758240141238None1.3.3Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 32 mm dia 2.5 mm thick m123.9123.91200.0FalseNoneNoneFalseNoneFalse148680.00
3758241141238None1.4.7Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 200 x 200 x 65 mm Each395.3395.336.0FalseNoneNoneFalseNoneFalse14230.80
3758242141238None1.5.1Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box Each57.8257.82150.0FalseNoneNoneFalseNoneFalse8673.00
3758243141238None1.5.2Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box Each60.1860.18130.0FalseNoneNoneFalseNoneFalse7823.40
3758244141238None1.12Supplying And Fixing Metal Fan Box with Round Hook. No192.34192.3481.0FalseNoneNoneFalseNoneFalse15579.540
3758245141238None1.9.1Supplying PVC/GI flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 20 mm m29.529.515.0FalseNoneNoneFalseNoneFalse442.50
3758246141238None1.9.2Supplying PVC/GI flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm m36.5836.5820.0FalseNoneNoneFalseNoneFalse731.60
3758247141238None1.9.3Supplying PVC/GI flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 32 mm m48.3848.3825.0FalseNoneNoneFalseNoneFalse1209.50
3758248141238None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3 Way Each145.14145.1461.0FalseNoneNoneFalseNoneFalse8853.540
3758249141238None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way Each162.84162.842.0FalseNoneNoneFalseNoneFalse325.680
3758250141238None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way Each250.16250.1615.0FalseNoneNoneFalseNoneFalse3752.40
3758251141238None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way Each295.0295.0144.0FalseNoneNoneFalseNoneFalse42480.00
3758252141238None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way Each383.5383.539.0FalseNoneNoneFalseNoneFalse14956.50
3758253141238None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module Each179.36179.3661.0FalseNoneNoneFalseNoneFalse10940.960
3758254141238None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module Each206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3758255141238None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module Each287.92287.9215.0FalseNoneNoneFalseNoneFalse4318.80
3758256141238None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module Each356.36356.36130.0FalseNoneNoneFalseNoneFalse46326.80
3758257141238None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module Each428.34428.3439.0FalseNoneNoneFalseNoneFalse16705.260
3758258141238None3.13.2Supplying and fixing of metal clad industrial plugs and sockets. 20 Amps 2pole+earth 250V PLUG Each259.6259.62.0FalseNoneNoneFalseNoneFalse519.20
3758259141238None3.13.6Supplying and fixing of metal clad industrial plugs and sockets. 20 Amps 2pole+earth 250V SOCKET Each305.62305.622.0FalseNoneNoneFalseNoneFalse611.240
3758260141238None3.9Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws. cm0.310.3120000.0FalseNoneNoneFalseNoneFalse6200.00
3758261141238None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch box Point296.18296.1850.0FalseNoneNoneFalseNoneFalse14809.00
3758262141238None2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch box Point425.98425.9870.0FalseNoneNoneFalseNoneFalse29818.60
3758263141238None2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch box Point639.56639.5630.0FalseNoneNoneFalseNoneFalse19186.80
3758264141238None2.3.1Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1 mm2 m21.2421.241000.0FalseNoneNoneFalseNoneFalse21240.00
3758265141238None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 m30.6830.681200.0FalseNoneNoneFalseNoneFalse36816.00
3758266141238None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 m47.247.21200.0FalseNoneNoneFalseNoneFalse56640.00
3758267141238None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 mm2 m69.6269.62800.0FalseNoneNoneFalseNoneFalse55696.00
3758268141238None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 mm2 m102.66102.66300.0FalseNoneNoneFalseNoneFalse30798.00
3758269141238None2.5.9Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS-694:2010 4C x 2.5 mm2 m166.38166.38120.0FalseNoneNoneFalseNoneFalse19965.60
3758270141238None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch Each103.84103.84400.0FalseNoneNoneFalseNoneFalse41536.00
3758271141238None3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way Switch Each179.36179.364.0FalseNoneNoneFalseNoneFalse717.440
3758272141238None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket Each191.16191.16200.0FalseNoneNoneFalseNoneFalse38232.00
3758273141238None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module Each369.34369.3470.0FalseNoneNoneFalseNoneFalse25853.80
3758274141238None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Bell Push Each187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3758275141238None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Bell Push Each187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3758276141238None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket Each293.82293.8240.0FalseNoneNoneFalseNoneFalse11752.80
3758277141238None3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket Each173.46173.464.0FalseNoneNoneFalseNoneFalse693.840
3758278141238None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch Each442.5442.540.0FalseNoneNoneFalseNoneFalse17700.00
3758279141238None5.18.8Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 8 Way SP & N II - Double Door Each2000.12000.12.0FalseNoneNoneFalseNoneFalse4000.20
3758280141238None5.18.9Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 12 Way SP & N II - Double Door Each2439.062439.064.0FalseNoneNoneFalseNoneFalse9756.240
3758281141238None5.18.11Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 4 Way TP & N III - Double Door Each3602.543602.549.0FalseNoneNoneFalseNoneFalse32422.860
3758282141238None5.17.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP Each617.14617.1440.0FalseNoneNoneFalseNoneFalse24685.60
3758283141238None5.17.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP Each1301.541301.5422.0FalseNoneNoneFalseNoneFalse28633.880
3758284141238None5.17.8Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A TPN Each2823.742823.7410.0FalseNoneNoneFalseNoneFalse28237.40
3758285141238None12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell Each282.02282.022.0FalseNoneNoneFalseNoneFalse564.040
3758286141238None11.14.1Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 2' Tube light fitting. Each254.88254.887.0FalseNoneNoneFalseNoneFalse1784.160
3758287141238None11.14.2Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 4' Tube light fitting. Each382.32382.32100.0FalseNoneNoneFalseNoneFalse38232.00
3758288141238None11.10.1Supplying & fixing of Surface mounting type retrofit type -LED tube . W comprising of LED linear source with CCT 6500 degree K, CRI 70perc. efficacy GTS 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF GTS 0.95, power loss should STS 5perc of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V.BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 8W-10W (T8) Each245.44245.447.0FalseNoneNoneFalseNoneFalse1718.080
3758289141238None11.10.2Supplying & fixing of Surface mounting type retrofit type -LED tube . W comprising of LED linear source with CCT 6500 degree K, CRI 70perc. efficacy GTS 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF GTS 0.95, power loss should STS 5perc of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V.BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18W-20W (T8) Each352.82352.8280.0FalseNoneNoneFalseNoneFalse28225.60
3758290141238None11.11.5Supplying & fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIsmall70 . efficacy gretr 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF gretr0.95, power loss should smalr 5 of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 , Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12W, 6500KEach279.66279.6634.0FalseNoneNoneFalseNoneFalse9508.440
3758291141238None12.46Supplying & Fixing of 70-150 W lamp holder 2 Pin No139.24139.2434.0FalseNoneNoneFalseNoneFalse4734.160
3758292141238None6.2.1Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) Each3536.463536.4610.0FalseNoneNoneFalseNoneFalse35364.60
3758293141238None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model Each2460.32460.330.0FalseNoneNoneFalseNoneFalse73809.00
3758294141238None6.5.1Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. 300 mm Sweep Each3124.643124.641.0FalseNoneNoneFalseNoneFalse3124.640
3758295141238None11.8.4Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70 , maximum light intensity should be between 60 degrees to 70 degrees. CCT smalr 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire grtr IK08. Power Factorsmallr0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency grtr1301m/w, nominal CRI smalr75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 90 W No9176.869176.868.0FalseNoneNoneFalseNoneFalse73414.880
3758296141238None13.1.2Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket 1x40/2x40 W fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clA, bolts, and nuts and wiring using suitable capacity wires. Using 32mm dia G.I.Pipe Each1064.361064.364.0FalseNoneNoneFalseNoneFalse4257.440
3758297141238None13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamp, bolts, nuts and wiring using suitable capacity wires. Each223.02223.028.0FalseNoneNoneFalseNoneFalse1784.160
3758298141238None13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Each191.16191.1631.0FalseNoneNoneFalseNoneFalse5925.960
3758299141238None13.12Extra length of GI pipe of class B 19mm dia for down rod. m204.14204.1460.0FalseNoneNoneFalseNoneFalse12248.40
3758300141238None13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. Each828.36828.3610.0FalseNoneNoneFalseNoneFalse8283.60
3758301141238None8.1Supplying and drawing UTP-CAT 6E LAN cable. m40.1240.121500.0FalseNoneNoneFalseNoneFalse60180.00
3758302141238None8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pair m22.4222.42900.0FalseNoneNoneFalseNoneFalse20178.00
3758303141238None8.4.3Supplying & Fixing of switch mounting rack with power manager & Cable manager. 9U with 450mm depth Each8904.288904.281.0FalseNoneNoneFalseNoneFalse8904.280
3758304141238None8.9.2Supplying fixing of Network Switches 24 Port Gigabyte (manageable) Each54342.5454342.541.0FalseNoneNoneFalseNoneFalse54342.540
3758305141238None8.10.1Supplying & fixing of I/O socket with back box Single I/O Each477.9477.946.0FalseNoneNoneFalseNoneFalse21983.40
3758306141238None8.12.5Supplying & Fixing of Patch panel for LAN cabling 24 Port 10/100/1000 patch panel Each9746.89746.81.0FalseNoneNoneFalseNoneFalse9746.80
3758307141238None8.11.1Supplying & Fixing of . ms Cat 6 Patch Cable - 1 m Each224.2224.246.0FalseNoneNoneFalseNoneFalse10313.20
3758308141238None6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries. Each5399.685399.683.0FalseNoneNoneFalseNoneFalse16199.040
3758309141238None9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS Each93422.9693422.961.0FalseNoneNoneFalseNoneFalse93422.960
3758310141238None9.2.5Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. 5 kVA OFF LINE UPS Each45619.9845619.981.0FalseNoneNoneFalseNoneFalse45619.980
3758311141238None9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150 AH capacity Each22934.4822934.483.0FalseNoneNoneFalseNoneFalse68803.440
3758312141238None5.7.5Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 200 A Each1486.81486.86.0FalseNoneNoneFalseNoneFalse8920.80
3758313141238None5.40.1Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Strips m2612.522612.529.0FalseNoneNoneFalseNoneFalse23512.680
3758314141238None5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 A Each1400.661400.661.0FalseNoneNoneFalseNoneFalse1400.660
3758315141238None5.11.4Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution) 200 A Each14261.4814261.481.0FalseNoneNoneFalseNoneFalse14261.480
3758316141238None13.18.2Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling. 100A to 250A TPST Each483.8483.81.0FalseNoneNoneFalseNoneFalse483.80
3758317141238None5.14.1Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100 A 25 kA - THREE Pole Each6656.386656.384.0FalseNoneNoneFalseNoneFalse26625.520
3758318141238None5.4.10Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 200 A 35 kA - FOUR Pole Each25121.0225121.022.0FalseNoneNoneFalseNoneFalse50242.040
3758319141238None5.20.4Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 63 A 4 pole Each3608.443608.441.0FalseNoneNoneFalseNoneFalse3608.440
3758320141238None5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. Each9812.889812.881.0FalseNoneNoneFalseNoneFalse9812.880
3758321141238None5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy Each9876.69876.61.0FalseNoneNoneFalseNoneFalse9876.60
3758322141238None5.36Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer Each892.08892.083.0FalseNoneNoneFalseNoneFalse2676.240
3758323141238None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. Each547.52547.523.0FalseNoneNoneFalseNoneFalse1642.560
3758324141238None5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG cm0.510.51100000.0FalseNoneNoneFalseNoneFalse51000.00
3758325141238None5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm m324.5324.55.0FalseNoneNoneFalseNoneFalse1622.50
3758326141238NoneCivilEarth Work in surface excavation for stripping, seating, of bund, Road way, by manula etc (Vol.1 page:80, Sl.No.1.1) Mtr82.682.670.0FalseNoneNoneFalseNoneFalse5782.00
3758327141238NoneCivilSupplying, laying and jointing HDPE Pipe of specified grade and conforming to IS 4984-2016 etc (All pages with photos, Page:150, Sl.No.1.5) HDPE Grade PE80-PN6.0, 125mm dia Mtr512.12512.1270.0FalseNoneNoneFalseNoneFalse35848.40
17234597010001NoneNoneBuildingsCONSTRUCTION OF GOVERNAMENT INDUSTRIAL TRAINING INSTITUTE (ITI) 5 TRADES COLLEGE AT HAROHALLI IN KANAKAPURA TALUK, RAMANAGARA DIST(PART-B)590330.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3758328141239NoneBESCOMSupplying and fixing of Earthing Materials Pipe type for grounding (Single Electrode with accessories as per BESCOM Specification. (BESCOM part-v, Cost data Sheet complete, Page-24, Sl.No.7) Set2600.32600.38.0FalseNoneNoneFalseNoneFalse20802.40
3758329141239NoneBESCOMSupplying of GI Pipe B-Class as per IS-1239 as per BESCOM Specification - 40mm (BESCOM Part-III, 11KV Materials, P-16, SN.-409) Mtr295.0295.08.0FalseNoneNoneFalseNoneFalse2360.00
3758330141239NoneBESCOMSupplying of GI Wire 8 SWG as per BESCOM Specification. (BESCOM part-v, Cost data Sheet complete, Page-24, Sl.No.7) Kg77.8577.8540.0FalseNoneNoneFalseNoneFalse3114.00
3758331141239NoneCDS-25Supplying and Erection of 3 Phase, 11kV 433V, 63 kVA BEE - 4 5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V Page 26, CDS 25) Supplying and Errection of DP Transformer Structure using RCC Pole - 9 Mtr Long, 145 Kg WL No38694.938694.91.0FalseNoneNoneFalseNoneFalse38694.90
3758332141239NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page 26, CDS-25) Supplying of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) Set221.0221.03.0FalseNoneNoneFalseNoneFalse663.00
3758333141239NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying of 11 kV, 45 KN Polymeric Insulator Set202.0202.03.0FalseNoneNoneFalseNoneFalse606.00
3758334141239NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying of Fixing of Guy Set Complete with No.15 Strain Insulator & Concreting materialsNo1737.641737.644.0FalseNoneNoneFalseNoneFalse6950.560
3758335141239NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying and Errection of 11kV/433V, 63 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with Oil No177275.34177275.341.0FalseNoneNoneFalseNoneFalse177275.340
3758336141239NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying and Fixing of Earthing materials pipe type for grounding (Single Electrode with accessories) Set2600.32600.33.0FalseNoneNoneFalseNoneFalse7800.90
3758337141239NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying and fixing of Caution/Danger Board No217.98217.981.0FalseNoneNoneFalseNoneFalse217.980
3758338141239NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying and fixing of Anti Climbing Device (12 Mtr GI Barbed Wire) Each130.76130.762.0FalseNoneNoneFalseNoneFalse261.520
3758339141239NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Fixing of Guy concreting with Boulders, Mud and Sand No236.0236.04.0FalseNoneNoneFalseNoneFalse944.00
3758340141239NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying of GI Wire 8 SWG Kg77.8577.855.0FalseNoneNoneFalseNoneFalse389.250
3758341141239NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying of Guy wire 7/10 SWG Kg80.1280.1210.0FalseNoneNoneFalseNoneFalse801.20
3758342141239NoneCDS-25Supplying and Fixing of 11 kV Lightning Arrester, Metal Oxide 9 kV, 5 kA, Polymetic type with ground disconnector (PART V - Page: 26, CDS-25) Set1842.21842.21.0FalseNoneNoneFalseNoneFalse1842.20
3758343141239NoneBESCOMSupplying and Fixing of a) LT Protection Kit for 63 kVA (PART V - Page: 26, CDS-25) No2221.82221.82.0FalseNoneNoneFalseNoneFalse4443.60
3758344141239NoneBESCOMb) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT (PART V - Page: 26, CDS-25) No848.42848.421.0FalseNoneNoneFalseNoneFalse848.420
3758345141239NoneBESCOMb) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT (PART V - Page: 26, CDS-25) i) Al Lead Wire - 95 Sqmm Mtr140.8140.840.0FalseNoneNoneFalseNoneFalse5632.00
3758346141239NoneBESCOMb) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT (PART V - Page: 26, CDS-25) ii) Heavy Duty Long Barrel Copper Lug - 95 Sqmm No133.0133.04.0FalseNoneNoneFalseNoneFalse532.00
3758347141239NoneBESCOMb) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT (PART V - Page: 26, CDS-25) iii) PG Clamp - Rabbit to 95 Sqmm No159.0159.04.0FalseNoneNoneFalseNoneFalse636.00
3758348141239NoneBESCOMb) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT (PART V - Page: 26, CDS-25) iv) Spacer for DTC Wiring No41.041.08.0FalseNoneNoneFalseNoneFalse328.00
3758349141239NoneBESCOMb) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT (PART V - Page: 26, CDS-25) v) Fish Plate with necessary Clamps, bolts & nuts etc complete (Galvanised) No229.0229.02.0FalseNoneNoneFalseNoneFalse458.00
3758350141239NoneCDS-25Supplying and fixing of c) LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS - 39) (PART V - Page: 26, CDS-25) No6345.06345.01.0FalseNoneNoneFalseNoneFalse6345.00
3758351141239NoneCDS-25Supplying of fixing of d) LT Electronic Tri-Vector Meter 5 Amps, -0.5/1.0 Accuracy Class (PART V - Page: 26, CDS-25) No4253.644253.641.0FalseNoneNoneFalseNoneFalse4253.640
3758352141239NoneCDS-25Supplying of fixing of 11 kV, Solid Core Type HG Fuse Unit (PART V - Page: 27, CDS-25) Set1973.641973.641.0FalseNoneNoneFalseNoneFalse1973.640
3758353141239NoneCDS-25Supplying of fixing of 11 kV, 200 Amps, Single Break GOS (PART V - Page: 27, CDS-25) Set10074.910074.91.0FalseNoneNoneFalseNoneFalse10074.90
3758354141239NoneCDS-1Supplying and fixing of RCC Pole - 9mtr Long, 145kg WL as per BESCOM Specification (BESCOM SR Part V, Page:1, Sl.No.1 CDS-1) (PART V - Page: 1, CDS-1) No8735.388735.384.0FalseNoneNoneFalseNoneFalse34941.520
3758355141239None32.03Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 as per BESCOM specification. (BESCOM SR PART III-11KV Materials, Page: 9) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)(BESCOM Part-III - 11 kV Materails, Page - 9, SL.No.32.03) Km148612.0148612.00.2FalseNoneNoneFalseNoneFalse29722.40
3758356141239None32.03Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 as per BESCOM specification. (BESCOM SR PART III-11KV Materials, Page: 9) 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)(BESCOM Part-III - 11 kV Materails, Page - 9, SL.No.32.03) Km183442.0183442.00.1FalseNoneNoneFalseNoneFalse18344.20
3758357141239NoneSL.No.222Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 as per BESCOM specification. (BESCOM SR PART III-11KV Materials, Page: 9) 50 Sqmm, 4 Core, (17 GI Strips - 4 x 0.8 mm) (Page - 9-27, SL.No.222) Km296715.0296715.00.1FalseNoneNoneFalseNoneFalse29671.50
3758358141239NoneSl.No.:11Labour charges for Laying of XLPE UG Cable Using Conventional Laying with Excavation of Soil (BESCOM SR Part V - CDS-19, Page:19, Sl.No.:11) a) Cable trench excavation, 1000x0.6x0.6=360, Ordinary soil cm306.8306.8200.0FalseNoneNoneFalseNoneFalse61360.00
3758359141239NoneSl.No.:11Labour charges for Laying of XLPE UG Cable Using Conventional Laying with Excavation of Soil (BESCOM SR Part V - CDS-19, Page:19, Sl.No.:11) b) Laying of cable in trench Km53435.1253435.120.4FalseNoneNoneFalseNoneFalse21374.0480
3758360141239NoneSl.No.:11Labour charges for Laying of XLPE UG Cable Using Conventional Laying with Excavation of Soil (BESCOM SR Part V - CDS-19, Page:19, Sl.No.:11) c) Refilling and consolidation cm68.4468.44360.0FalseNoneNoneFalseNoneFalse24638.40
3758361141239NoneSl.No.:11Labour charges for Laying of XLPE UG Cable Using Conventional Laying with Excavation of Soil (BESCOM SR Part V - CDS-19, Page:19, Sl.No.:11) h) Supplying and fixing of RCC Hume pipe Mtr360.18360.18100.0FalseNoneNoneFalseNoneFalse36018.00
3758362141239NoneCDS-1, Sl.No.:9Supplying and Stringing of Rabbit ACSR Conductor as per BESCOM Specification (Part-V, CDS-1, Sl.No.:9) Km65407.8265407.820.4FalseNoneNoneFalseNoneFalse26163.1280
3758363141239NoneSl.No.:5Supplying and fixing of 4 pin cross arm as per BESCOM Specification (CDS-5, Sl.No.:5) Set582.96582.966.0FalseNoneNoneFalseNoneFalse3497.760
3758364141239NoneSl.No.:5Supplying and fixing of 2 pin cross arm as per BESCOM Specification (CDS-10, Sl.No.:5) Set417.96417.966.0FalseNoneNoneFalseNoneFalse2507.760
3758365141239NoneSl.No.:7Supplying of 1.1KV Pin Insulator as per BESCOM Specification (CDS-10, Sl.No.:7) No65.065.024.0FalseNoneNoneFalseNoneFalse1560.00
3758366141239NoneSl.No.:8Supplying of No.8 Strain Insulator as per BESCOM Specification (CDS-10, Sl.No.:8) No25.025.012.0FalseNoneNoneFalseNoneFalse300.00
3758367141239NoneSl.No.:8Supplying and fixing of Spiral earth electrode as per BESCOM Specification (CDS-10, Sl.No.:8) No330.6330.66.0FalseNoneNoneFalseNoneFalse1983.60
17234609390000NoneNoneBuildingsCONSTRUCTION OF GOVERNAMENT INDUSTRIAL TRAINING INSTITUTE ( I T I ) 5 TRADES COLLEGE AT HAROHALLI IN KANAKAPURA TALUK, RAMANAGARA DIST.43802758.62
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3758794141261None1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m (P. No - 8, I. No - 1.14.1, S R 2023-24, Vol-1 - Common S R)Cum123.97123.97161.26FalseNoneNoneFalseNoneFalse19991.40220
3758751141261None1.17.1Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m (P. No - 10, I. No - 1.17.1, S R 2023-24, Vol-1 - Common S R)Cum318.43318.43138.71FalseNoneNoneFalseNoneFalse44169.42530
3758806141261None1.2.1Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick m71.9871.981200.0FalseNoneNoneFalseNoneFalse86376.00
3758780141261None12.4Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. (P. No - 140, I. No - 12.4, S R 2023-24, Vol-5-For BWSSB)Each6427.046427.041.0FalseNoneNoneFalseNoneFalse6427.040
3758692141261None2.5 (ii) AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer By Mechanical Means using Dozer (P. No - 9, I. No - 2.5 (ii) A, Vol-3) 100 Sqm477.65477.6580.98FalseNoneNoneFalseNoneFalse38680.0970
3758897141261NoneBESCOMSupplying and fixing of Earthing Materials Pipe type for grounding (Single Electrode with accessories as per BESCOM Specification. (BESCOM part-v, Cost data Sheet complete, Page-24, Sl.No.7) Set2600.32600.38.0FalseNoneNoneFalseNoneFalse20802.40
3758752141261None1.10Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications (P. No - 7, I. No - 1.10, S R 2023-24, Vol-1 - Common S R)Cum194.46194.46113.4FalseNoneNoneFalseNoneFalse22051.7640
3758693141261None1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (P. No - 8, I. No - 1.12, Vol-1 - Common S R)Cum115.46115.461214.4FalseNoneNoneFalseNoneFalse140214.6240
3758807141261None1.2.2Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick m82.682.6800.0FalseNoneNoneFalseNoneFalse66080.00
3758781141261None12.1.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 0 to 50 Mtrs (P. No - 139, I. No - 12.1.1, S R 2023-24, Vol-5-For BWSSB)m449.7449.750.0FalseNoneNoneFalseNoneFalse22485.00
3758795141261None2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (P. No - 15, I. No - 2.1.2, S R 2023-24, Vol-1 - Common S R)Cum6884.036884.036.32FalseNoneNoneFalseNoneFalse43507.06960
3758898141261NoneBESCOMSupplying of GI Pipe B-Class as per IS-1239 as per BESCOM Specification - 40mm (BESCOM Part-III, 11KV Materials, P-16, SN.-409) Mtr295.0295.08.0FalseNoneNoneFalseNoneFalse2360.00
3758694141261None1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m (P. No - 8, I. No - 1.14.1, S R 2023-24, Vol-1 - Common S R)Cum123.97123.971723.13FalseNoneNoneFalseNoneFalse213616.42610
3758808141261None1.3.2Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick m94.494.41000.0FalseNoneNoneFalseNoneFalse94400.00
3758782141261None12.1.2Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 50 to 100 Mtrs (P. No - 139, I. No - 12.1.2, S R 2023-24, Vol-5-For BWSSB)m563.95563.9550.0FalseNoneNoneFalseNoneFalse28197.50
3758753141261None16.62.2Providing to work spot rolling, lowering and placing in position RCC perforated rings in the already excavated pit including loading and unloading at both the destinations with all lead and lift with appurtenances., complete. 1200 mmx1250 mm (P. No - 208, I. No - 16.62.2, S R 2023-24, Vol-5-For BWSSB)Each11599.7811599.783.0FalseNoneNoneFalseNoneFalse34799.340
3758796141261None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P. No - 15, I. No - 2.2.1, S R 2023-24, Vol-1 - Common S R)Cum8012.158012.1510.3FalseNoneNoneFalseNoneFalse82525.1450
3758899141261NoneBESCOMSupplying of GI Wire 8 SWG as per BESCOM Specification. (BESCOM part-v, Cost data Sheet complete, Page-24, Sl.No.7) Kg77.8577.8540.0FalseNoneNoneFalseNoneFalse3114.00
3758695141261None1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m, In ordinary/soft rock without blasting upto 1.5 m depth(P. No - 8, I. No - 1.15.1, S R 2023-24, Vol-1 - Common S R)Cum441.19441.19191.47FalseNoneNoneFalseNoneFalse84474.64930
3758809141261None1.3.3Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 32 mm dia 2.5 mm thick m123.9123.91200.0FalseNoneNoneFalseNoneFalse148680.00
3758783141261None12.1.3Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 100 to 150 Mtrs (P. No - 139, I. No - 12.1.3, S R 2023-24, Vol-5-For BWSSB)m599.19599.1950.0FalseNoneNoneFalseNoneFalse29959.50
3758754141261None16.61.2Supply and fixing of SFRC machinhole cover (Medium Duty) made as per IS to suit existing damaged machinhole cover after removing the debries from inside and outside the existing machinhole etc. with all lead and lifts. Heavy Duty (P. No - 208, I. No - 16.61.2, S R 2023-24, Vol-5-For BWSSB)Each1498.581498.583.0FalseNoneNoneFalseNoneFalse4495.740
3758797141261None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P. No - 15, I. No - 2.2.1, S R 2023-24, Vol-1 - Common S R)Cum8405.348405.3414.24FalseNoneNoneFalseNoneFalse119692.04160
3758900141261NoneCDS-25Supplying and Erection of 3 Phase, 11kV 433V, 63 kVA BEE - 4 5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V Page 26, CDS 25) Supplying and Errection of DP Transformer Structure using RCC Pole - 9 Mtr Long, 145 Kg WL No38694.938694.91.0FalseNoneNoneFalseNoneFalse38694.90
3758810141261None1.4.7Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 200 x 200 x 65 mm Each395.3395.336.0FalseNoneNoneFalseNoneFalse14230.80
3758696141261None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (P. No - 7, I. No - 1.9, S R 2023-24, Vol-1 - Common S R) Cum323.3323.31723.13FalseNoneNoneFalseNoneFalse557087.9290
3758755141261None10.1.5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 75mm dia., 6 kg/sqcm & class 3 (P. No - 113, I. No - 10.1.5, S R 2023-24, Vol-5-For BWSSB)m267.38267.3850.0FalseNoneNoneFalseNoneFalse13369.00
3758784141261None12.1.4Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 150 to 200 Mtrs (P. No - 139, I. No - 12.1.4, S R 2023-24, Vol-5-For BWSSB)m695.21695.2150.0FalseNoneNoneFalseNoneFalse34760.50
3758798141261None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P. No - 15, I. No - 2.2.1, S R 2023-24, Vol-1 - Common S R)Cum11461.8311461.836.83FalseNoneNoneFalseNoneFalse78284.29890
3758901141261NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page 26, CDS-25) Supplying of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) Set221.0221.03.0FalseNoneNoneFalseNoneFalse663.00
3758811141261None1.5.1Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box Each57.8257.82150.0FalseNoneNoneFalseNoneFalse8673.00
3758697141261None1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. (P. No - 7, I. No - 1.8, S R 2023-24, Vol-1 - Common S R) Cum576.1576.1162.14FalseNoneNoneFalseNoneFalse93408.8540
3758756141261None10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 110mm dia., 6 kg/sqcm & class 3 (P. No - 113, I. No - 10.1.7, S R 2023-24, Vol-5-For BWSSB)m499.52499.5280.0FalseNoneNoneFalseNoneFalse39961.60
3758785141261None12.1.5Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 200 to 250 Mtrs (P. No - 139, I. No - 12.1.5, S R 2023-24, Vol-5-For BWSSB)m815.53815.5350.0FalseNoneNoneFalseNoneFalse40776.50
3758799141261None16.62.2Providing to work spot rolling, lowering and placing in position RCC perforated rings in the already excavated pit including loading and unloading at both the destinations with all lead and lift with appurtenances., complete. 1200 mmx1250 mm (P. No - 208, I. No - 16.62.2, S R 2023-24, Vol-5-For BWSSB)Each11599.7811599.783.0FalseNoneNoneFalseNoneFalse34799.340
3758902141261NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying of 11 kV, 45 KN Polymeric Insulator Set202.0202.03.0FalseNoneNoneFalseNoneFalse606.00
3758812141261None1.5.2Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box Each60.1860.18130.0FalseNoneNoneFalseNoneFalse7823.40
3758757141261None10.1.9Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 160mm dia., 6 kg/sqcm & class 3 (P. No - 113, I. No - 10.1.9, S R 2023-24, Vol-5-For BWSSB)m751.11751.11150.0FalseNoneNoneFalseNoneFalse112666.50
3758786141261None12.32Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty (P. No - 143, I. No - 12.32, S R 2023-24, Vol-5-For BWSSB)m2349.372349.3720.0FalseNoneNoneFalseNoneFalse46987.40
3758800141261None16.61.2Supply and fixing of SFRC machinhole cover (Medium Duty) made as per IS to suit existing damaged machinhole cover after removing the debries from inside and outside the existing machinhole etc. with all lead and lifts. Heavy Duty (P. No - 208, I. No - 16.61.2, S R 2023-24, Vol-5-For BWSSB)Each1498.591498.591.0FalseNoneNoneFalseNoneFalse1498.590
3758698141261None4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. (P. No - 5, I. No - 4.1, S R 2023-24, Vol-2 - For Buildings)Sqm143.42143.421857.36FalseNoneNoneFalseNoneFalse266382.57120
3758903141261NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying of Fixing of Guy Set Complete with No.15 Strain Insulator & Concreting materialsNo1737.641737.644.0FalseNoneNoneFalseNoneFalse6950.560
3758813141261None1.12Supplying And Fixing Metal Fan Box with Round Hook. No192.34192.3481.0FalseNoneNoneFalseNoneFalse15579.540
3758787141261None12.34Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge (P. No - 143, I. No - 12.34, S R 2023-24No199.33199.331.0FalseNoneNoneFalseNoneFalse199.330
3758758141261None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter (P. No - 125, I. No - 13.48, S R 2023-24, Vol-2 - For Buildings)m353.68353.68100.0FalseNoneNoneFalseNoneFalse35368.00
3758699141261None2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labor, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (P. No - 15, I. No - 2.1.2, S R 2023-24, Vol-1 - Common S R)Cum6884.036884.03337.17FalseNoneNoneFalseNoneFalse2321088.39510
3758801141261None8.5.1Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P. No - 42, I. No - 8.5.1, S R 2023-24, Vol-2 - For Buildings)Sqm444.84444.84263.28FalseNoneNoneFalseNoneFalse117117.47520
3758904141261NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying and Errection of 11kV/433V, 63 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with Oil No177275.34177275.341.0FalseNoneNoneFalseNoneFalse177275.340
3758814141261None1.9.1Supplying PVC/GI flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 20 mm m29.529.515.0FalseNoneNoneFalseNoneFalse442.50
3758759141261None13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes (P. No - 122, I. No - 13.32.2, S R 2023-24, Vol-2 - For Buildings)m460.63460.63120.0FalseNoneNoneFalseNoneFalse55275.60
3758788141261None13.40.5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 5 HP, size 50x40 Head 46M, Discharge 174 LPM (P. No - 157, I. No - 13.40.5, S R 2023-24, Vol-5-For BWSSB)No32107.2232107.221.0FalseNoneNoneFalseNoneFalse32107.220
3758700141261None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (P. No - 9, I. No - 5.4, S R 2023-24, Vol-2 - For Buildings)Cum7765.197765.19104.58FalseNoneNoneFalseNoneFalse812083.57020
3758802141261None8.12Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge (P. No - 43, I. No - 8.12, S R 2023-24, Vol-2 - For Buildings)Sqm77.7977.79263.28FalseNoneNoneFalseNoneFalse20480.55120
3758905141261NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying and Fixing of Earthing materials pipe type for grounding (Single Electrode with accessories) Set2600.32600.33.0FalseNoneNoneFalseNoneFalse7800.90
3758815141261None1.9.2Supplying PVC/GI flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm m36.5836.5820.0FalseNoneNoneFalseNoneFalse731.60
3758789141261None13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (P. No - 156, I. No - 13.32, S R 2023-24, Vol-5-For BWSSB)Job7900.17900.11.0FalseNoneNoneFalseNoneFalse7900.10
3758760141261None13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes (P. No - 122, I. No - 13.33.3, S R 2023-24, Vol-2 - For Buildings)m359.76359.76100.0FalseNoneNoneFalseNoneFalse35976.00
3758803141261None2.11(a)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (P. No - 18, I. No - 2.11, S R 2023-24, Vol-1 - Common S R)Tonne108726.04108726.040.68FalseNoneNoneFalseNoneFalse73933.70720
3758701141261None2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P. No - 15, I. No - 2.2.3, S R 2023-24, Vol-1 - Common S R)Cum8316.848316.84371.33FalseNoneNoneFalseNoneFalse3088292.19720
3758906141261NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying and fixing of Caution/Danger Board No217.98217.981.0FalseNoneNoneFalseNoneFalse217.980
3758816141261None1.9.3Supplying PVC/GI flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 32 mm m48.3848.3825.0FalseNoneNoneFalseNoneFalse1209.50
3758790141261None13.22.4Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x6 m2 (P. No - 154, I. No - 13.22.4, S R 2023-24, Vol-5-For BWSSB)m224.85224.85200.0FalseNoneNoneFalseNoneFalse44970.00
3758761141261None13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes (P. No - 122, I. No - 13.33.5, S R 2023-24, Vol-2 - For Buildings)m579.75579.75100.0FalseNoneNoneFalseNoneFalse57975.00
3758804141261None13.40.2Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 50x40 Head 22M, Discharge 186 LPM (P. No - 157, I. No - 13.40.2, S R 2023-24, Vol-5-For BWSSB)No20653.2920653.291.0FalseNoneNoneFalseNoneFalse20653.290
3758702141261None2.3.2Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P. No - 16, I. No - 2.3.2, S R 2023-24, Vol-1 - Common S R)Cum13388.8513388.859.26FalseNoneNoneFalseNoneFalse123980.7510
3758907141261NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying and fixing of Anti Climbing Device (12 Mtr GI Barbed Wire) Each130.76130.762.0FalseNoneNoneFalseNoneFalse261.520
3758791141261None13.23.3Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter 6 to 15 HP pumps (P. No - 154, I. No - 13.23.3, S R 2023-24, Vol-5-For BWSSB)No19324.8619324.861.0FalseNoneNoneFalseNoneFalse19324.860
3758762141261None13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (P. No - 123, I. No - 13.34, S R 2023-24, Vol-2 - For Buildings)Ltr10.9410.944000.0FalseNoneNoneFalseNoneFalse43760.00
3758805141261None16.15.1Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm anddown size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame(P. No - 192, I. No - 16.15.1, S R 2023-24, Vol-5 - For BWSSB)Each35303.7235303.721.0FalseNoneNoneFalseNoneFalse35303.720
3758703141261None2.3.2Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P. No - 16, I. No - 2.3.2, S R 2023-24, Vol-1 - Common S R)Cum11813.6911813.6962.84FalseNoneNoneFalseNoneFalse742372.27960
3758817141261None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3 Way Each145.14145.1461.0FalseNoneNoneFalseNoneFalse8853.540
3758908141261NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Fixing of Guy concreting with Boulders, Mud and Sand No236.0236.04.0FalseNoneNoneFalseNoneFalse944.00
3758792141261None13.25.1Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm (P. No - 154, I. No - 13.25.1, S R 2023-24, Vol-5-For BWSSB)No1519.251519.252.0FalseNoneNoneFalseNoneFalse3038.50
3758763141261None13.54Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500X700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :With common burnt clay (non modular) bricks of class designation 3.5 (P. No - 126, I. No - 13.54, S R 2023-24, Vol-2 - For Buildings)No7630.287630.2810.0FalseNoneNoneFalseNoneFalse76302.80
3758704141261None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(P. No - 16, I. No - 2.5.2, S R 2023-24, Vol-1 - Common S R)Cum14138.8714138.8744.99FalseNoneNoneFalseNoneFalse636107.76130
3758818141261None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way Each162.84162.842.0FalseNoneNoneFalseNoneFalse325.680
3758909141261NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying of GI Wire 8 SWG Kg77.8577.855.0FalseNoneNoneFalseNoneFalse389.250
3758793141261None13.27.1Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover (P. No - 155, I. No - 13.27.1, S R 2023-24, Vol-5-For BWSSB)Each3706.973706.9710.0FalseNoneNoneFalseNoneFalse37069.70
3758764141261None14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (P. No - 131, I. No - 14.1.1, S R 2023-24, Vol-2-For Buildings)Each5936.015936.014.0FalseNoneNoneFalseNoneFalse23744.040
3758705141261None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(P. No - 16, I. No - 2.5.2, S R 2023-24, Vol-1 - Common S R)Cum13307.1713307.1794.06FalseNoneNoneFalseNoneFalse1251672.41020
3758819141261None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way Each250.16250.1615.0FalseNoneNoneFalseNoneFalse3752.40
3758910141261NoneCDS-25Supplying & Erection of 3 Phase, 11kV/433V, 63 kVA BEE - 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC as per BESCOM Specification (PART V - Page: 26, CDS-25) Supplying of Guy wire 7/10 SWG Kg80.1280.1210.0FalseNoneNoneFalseNoneFalse801.20
3758765141261None14.5.1Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern (P. No - 132, I. No - 14.5.1, S R 2023-24, Vol-2-For Buildings)Each10503.510503.56.0FalseNoneNoneFalseNoneFalse63021.00
3758706141261None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(P. No - 16, I. No - 2.5.2, S R 2023-24, Vol-1 - Common S R)Cum12475.4712475.47291.69FalseNoneNoneFalseNoneFalse3638969.84430
3758820141261None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way Each295.0295.0144.0FalseNoneNoneFalseNoneFalse42480.00
3758911141261NoneCDS-25Supplying and Fixing of 11 kV Lightning Arrester, Metal Oxide 9 kV, 5 kA, Polymetic type with ground disconnector (PART V - Page: 26, CDS-25) Set1842.21842.21.0FalseNoneNoneFalseNoneFalse1842.20
3758766141261None14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (P. No - 131, I. No - 14.3.1, S R 2023-24, Vol-2-For Buildings)Each7264.457264.4511.0FalseNoneNoneFalseNoneFalse79908.950
3758707141261None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(P. No - 16, I. No - 2.5.2, S R 2023-24, Vol-1 - Common S R)Cum12059.6212059.628.02FalseNoneNoneFalseNoneFalse96718.15240
3758821141261None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way Each383.5383.539.0FalseNoneNoneFalseNoneFalse14956.50
3758912141261NoneBESCOMSupplying and Fixing of a) LT Protection Kit for 63 kVA (PART V - Page: 26, CDS-25) No2221.82221.82.0FalseNoneNoneFalseNoneFalse4443.60
3758767141261None14.7AProviding and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (P. No - 133, I. No - 14.7A, S R 2023-24, Vol-2-For Buildings)Each5008.665008.6612.0FalseNoneNoneFalseNoneFalse60103.920
3758708141261None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (P. No - 18, I. No - 2.11, S R 2023-24, Vol-1 - Common S R)Tonne108726.04108726.0485.72FalseNoneNoneFalseNoneFalse9319996.14880
3758822141261None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module Each179.36179.3661.0FalseNoneNoneFalseNoneFalse10940.960
3758913141261NoneBESCOMb) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT (PART V - Page: 26, CDS-25) No848.42848.421.0FalseNoneNoneFalseNoneFalse848.420
3758768141261None14.8Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. (P. No - 133, I. No - 14.8, S R 2023-24, Vol-2-For Buildings)Each1729.511729.5112.0FalseNoneNoneFalseNoneFalse20754.120
3758823141261None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module Each206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3758709141261None6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P. No - 17, I. No - 6.32, S R 2023-24, Vol-2 - For Buildings)Sqm1592.171592.171811.45FalseNoneNoneFalseNoneFalse2884136.34650
3758914141261NoneBESCOMb) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT (PART V - Page: 26, CDS-25) i) Al Lead Wire - 95 Sqmm Mtr140.8140.840.0FalseNoneNoneFalseNoneFalse5632.00
3758769141261None13.22.1Providing and fixing PTMT grating of approved quality and colour. 100 mm nominal dia (P. No - 120, I. No - 13.22.1.1, S R 2023-24, Vol-2-For Buildings)Each49.8349.8335.0FalseNoneNoneFalseNoneFalse1744.050
3758824141261None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module Each287.92287.9215.0FalseNoneNoneFalseNoneFalse4318.80
3758710141261None6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P. No - 17, I. No - 6.34, S R 2023-24, Vol-2 - For Buildings)Sqm1341.81341.8436.06FalseNoneNoneFalseNoneFalse585105.3080
3758915141261NoneBESCOMb) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT (PART V - Page: 26, CDS-25) ii) Heavy Duty Long Barrel Copper Lug - 95 Sqmm No133.0133.04.0FalseNoneNoneFalseNoneFalse532.00
3758711141261None12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (P. No - 100, I. No - 12.13.1, S R 2023-24, Vol-2 - For Buildings)Cum120099.75120099.752.01FalseNoneNoneFalseNoneFalse241400.49750
3758770141261None14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia (P. No - 136, I. No - 14.28.2.2, S R 2023-24, Vol-2-For Buildings)Each111.82111.8222.0FalseNoneNoneFalseNoneFalse2460.040
3758825141261None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module Each356.36356.36130.0FalseNoneNoneFalseNoneFalse46326.80
3758916141261NoneBESCOMb) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT (PART V - Page: 26, CDS-25) iii) PG Clamp - Rabbit to 95 Sqmm No159.0159.04.0FalseNoneNoneFalseNoneFalse636.00
3758712141261None12.11Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (P. No - 99, I. No - 12.11, S R 2023-24, Vol-2 - For Buildings)Cum167815.14167815.140.15FalseNoneNoneFalseNoneFalse25172.2710
3758771141261None14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (P. No - 136, I. No - 14.31, S R 2023-24, Vol-2-For Buildings)Each1482.81482.812.0FalseNoneNoneFalseNoneFalse17793.60
3758826141261None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module Each428.34428.3439.0FalseNoneNoneFalseNoneFalse16705.260
3758917141261NoneBESCOMb) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT (PART V - Page: 26, CDS-25) iv) Spacer for DTC Wiring No41.041.08.0FalseNoneNoneFalseNoneFalse328.00
3758713141261None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) (P. No - 100, I. No - 12.15, S R 2023-24, Vol-2 - For Buildings)Sqm9047.449047.444.5FalseNoneNoneFalseNoneFalse40713.480
3758772141261None13.8.2.1Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore (P. No - 118, I. No - 13.8.2.1, S R 2023-24, Vol-2-For Buildings)No110.6110.635.0FalseNoneNoneFalseNoneFalse3871.00
3758827141261None3.13.2Supplying and fixing of metal clad industrial plugs and sockets. 20 Amps 2pole+earth 250V PLUG Each259.6259.62.0FalseNoneNoneFalseNoneFalse519.20
3758918141261NoneBESCOMb) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT (PART V - Page: 26, CDS-25) v) Fish Plate with necessary Clamps, bolts & nuts etc complete (Galvanised) No229.0229.02.0FalseNoneNoneFalseNoneFalse458.00
3758714141261None12.57.1Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick Both side teak (P. No - 105, I. No - 12.57.1, S R 2023-24, Vol-2 - For Buildings)Sqm4913.864913.8669.72FalseNoneNoneFalseNoneFalse342594.31920
3758773141261None13.12Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 (P. No - 119, I. No - 13.12, S R 2023-24, Vol-2-For Buildings)No771.8771.815.0FalseNoneNoneFalseNoneFalse11577.00
3758828141261None3.13.6Supplying and fixing of metal clad industrial plugs and sockets. 20 Amps 2pole+earth 250V SOCKET Each305.62305.622.0FalseNoneNoneFalseNoneFalse611.240
3758919141261NoneCDS-25Supplying and fixing of c) LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS - 39) (PART V - Page: 26, CDS-25) No6345.06345.01.0FalseNoneNoneFalseNoneFalse6345.00
3758715141261None11.30.1Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P. No - 85, I. No - 11.30.1, S R 2023-24, Vol-2 - For Buildings)Sqm1108.441108.4410.3FalseNoneNoneFalseNoneFalse11416.9320
3758774141261None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (P. No - 119, I. No - 13.16, S R 2023-24, Vol-2-For Buildings)No753.55753.5533.0FalseNoneNoneFalseNoneFalse24867.150
3758829141261None3.9Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws. cm0.310.3120000.0FalseNoneNoneFalseNoneFalse6200.00
3758920141261NoneCDS-25Supplying of fixing of d) LT Electronic Tri-Vector Meter 5 Amps, -0.5/1.0 Accuracy Class (PART V - Page: 26, CDS-25) No4253.644253.641.0FalseNoneNoneFalseNoneFalse4253.640
3758716141261None12.96Providing and fixing Fibre Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm X 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibre glass fromm all sides. M S stay shall be provided at the bottom to steady the frame. (P. No - 112, I. No - 12.96, S R 2023-24 Vol-2 - For Buildings )m781.5781.566.3FalseNoneNoneFalseNoneFalse51813.450
3758775141261None13.20.2Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms (P. No - 120, I. No - 13.20.2, S R 2023-24, Vol-2-For Buildings)No381.64381.6412.0FalseNoneNoneFalseNoneFalse4579.680
3758830141261None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch box Point296.18296.1850.0FalseNoneNoneFalseNoneFalse14809.00
3758921141261NoneCDS-25Supplying of fixing of 11 kV, Solid Core Type HG Fuse Unit (PART V - Page: 27, CDS-25) Set1973.641973.641.0FalseNoneNoneFalseNoneFalse1973.640
3758717141261None12.97.1Providing and fixing to Existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and maufacture, made with fire - resistant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP lamonate for panels confirming to IS; 14856 including fixing to frames. (P. No - 112, I. No - 12.97.1, S R 2023-24 Vol-2 - For Buildings)Sqm3894.143894.1424.57FalseNoneNoneFalseNoneFalse95679.01980
3758776141261None13.21.1Providing and fixing PTMT, push cock of approved quality and colour. 15 mm nominal bore, 98 mm long, weighing not less than 75 gms (P. No - 120, I. No - 13.21.1, S R 2023-24, Vol-2-For Buildings)No155.57155.5710.0FalseNoneNoneFalseNoneFalse1555.70
3758831141261None2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch box Point425.98425.9870.0FalseNoneNoneFalseNoneFalse29818.60
3758922141261NoneCDS-25Supplying of fixing of 11 kV, 200 Amps, Single Break GOS (PART V - Page: 27, CDS-25) Set10074.910074.91.0FalseNoneNoneFalseNoneFalse10074.90
3758718141261None12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (P. No - 104, I. No - 12.51, S R 2023-24 Vol-2 - For Buildings)No1234.851234.8528.0FalseNoneNoneFalseNoneFalse34575.80
3758777141261None13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore (P. No - 117, I. No - 13.5.3, S R 2023-24, Vol-2-For Buildings)No403.51403.518.0FalseNoneNoneFalseNoneFalse3228.080
3758832141261None2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch box Point639.56639.5630.0FalseNoneNoneFalseNoneFalse19186.80
3758923141261NoneCDS-1Supplying and fixing of RCC Pole - 9mtr Long, 145kg WL as per BESCOM Specification (BESCOM SR Part V, Page:1, Sl.No.1 CDS-1) (PART V - Page: 1, CDS-1) No8735.388735.384.0FalseNoneNoneFalseNoneFalse34941.520
3758719141261None11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (P. No - 86, I. No - 11.34A, S R 2023-24, Vol-2 - For Buildings)Kgs204.19204.194858.56FalseNoneNoneFalseNoneFalse992069.36640
3758778141261None13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms (P. No - 121, I. No - 13.25, S R 2023-24, Vol-2-For Buildings)No177.45177.4511.0FalseNoneNoneFalseNoneFalse1951.950
3758833141261None2.3.1Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1 mm2 m21.2421.241000.0FalseNoneNoneFalseNoneFalse21240.00
3758924141261None32.03Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 as per BESCOM specification. (BESCOM SR PART III-11KV Materials, Page: 9) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)(BESCOM Part-III - 11 kV Materails, Page - 9, SL.No.32.03) Km148612.0148612.00.2FalseNoneNoneFalseNoneFalse29722.40
3758720141261None12.87Providing and fixing of 2.5 track x 2 -panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm Windows shall be provided with 5mm plain float glass standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8-2.0mm. Maximum possible size 1519mmx1519mm (The cost is inclusive of all fixtures and separate charges for minor T and Ps shall not be made (P. No - 109 I. No-12.87 S R 2023-24,Vol-2 For Buildings)Sqm7962.097962.09215.1FalseNoneNoneFalseNoneFalse1712645.5590
3758779141261None13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. (P. No - 121, I. No - 13.26, S R 2023-24, Vol-2-For Buildings)No121.54121.5412.0FalseNoneNoneFalseNoneFalse1458.480
3758834141261None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 m30.6830.681200.0FalseNoneNoneFalseNoneFalse36816.00
3758925141261None32.03Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 as per BESCOM specification. (BESCOM SR PART III-11KV Materials, Page: 9) 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)(BESCOM Part-III - 11 kV Materails, Page - 9, SL.No.32.03) Km183442.0183442.00.1FalseNoneNoneFalseNoneFalse18344.20
3758721141261None12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P. No - 109 I. No 12.85 S R 202324, Vol-2 For Buildings)Sqm6950.876950.8716.26FalseNoneNoneFalseNoneFalse113021.14620
3758835141261None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 m47.247.21200.0FalseNoneNoneFalseNoneFalse56640.00
3758926141261NoneSL.No.222Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 as per BESCOM specification. (BESCOM SR PART III-11KV Materials, Page: 9) 50 Sqmm, 4 Core, (17 GI Strips - 4 x 0.8 mm) (Page - 9-27, SL.No.222) Km296715.0296715.00.1FalseNoneNoneFalseNoneFalse29671.50
3758722141261None12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size- 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P. No - 111, I. No - 12.92, S R 2023-24, Vol-2 - For Buildings)Sqm7590.177590.173.78FalseNoneNoneFalseNoneFalse28690.84260
3758836141261None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 mm2 m69.6269.62800.0FalseNoneNoneFalseNoneFalse55696.00
3758927141261NoneSl.No.:11Labour charges for Laying of XLPE UG Cable Using Conventional Laying with Excavation of Soil (BESCOM SR Part V - CDS-19, Page:19, Sl.No.:11) a) Cable trench excavation, 1000x0.6x0.6=360, Ordinary soil cm306.8306.8200.0FalseNoneNoneFalseNoneFalse61360.00
3758723141261None11.6.1Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P. No - 78, I. No - 11.6.1, S R 2023-24, Vol-2 - For Buildings)Sqm3200.153200.1525.65FalseNoneNoneFalseNoneFalse82083.84750
3758837141261None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 mm2 m102.66102.66300.0FalseNoneNoneFalseNoneFalse30798.00
3758928141261NoneSl.No.:11Labour charges for Laying of XLPE UG Cable Using Conventional Laying with Excavation of Soil (BESCOM SR Part V - CDS-19, Page:19, Sl.No.:11) b) Laying of cable in trench Km53435.1253435.120.4FalseNoneNoneFalseNoneFalse21374.0480
3758838141261None2.5.9Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS-694:2010 4C x 2.5 mm2 m166.38166.38120.0FalseNoneNoneFalseNoneFalse19965.60
3758724141261None8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P. No - 43, I. No - 8.10, S R 2023-24, Vol-2 - For Buildings)Sqm256.45256.451787.21FalseNoneNoneFalseNoneFalse458330.00450
3758929141261NoneSl.No.:11Labour charges for Laying of XLPE UG Cable Using Conventional Laying with Excavation of Soil (BESCOM SR Part V - CDS-19, Page:19, Sl.No.:11) c) Refilling and consolidation cm68.4468.44360.0FalseNoneNoneFalseNoneFalse24638.40
3758839141261None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch Each103.84103.84400.0FalseNoneNoneFalseNoneFalse41536.00
3758725141261None8.1.2Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P. No - 41, I. No - 8.1.2, S R 2023-24, Vol-2 - For Buildings)Sqm292.91292.913596.98FalseNoneNoneFalseNoneFalse1053591.41180
3758930141261NoneSl.No.:11Labour charges for Laying of XLPE UG Cable Using Conventional Laying with Excavation of Soil (BESCOM SR Part V - CDS-19, Page:19, Sl.No.:11) h) Supplying and fixing of RCC Hume pipe Mtr360.18360.18100.0FalseNoneNoneFalseNoneFalse36018.00
3758840141261None3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way Switch Each179.36179.364.0FalseNoneNoneFalseNoneFalse717.440
3758726141261None8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P. No - 41, I. No - 8.2.2, S R 2023-24, Vol-2 - For Buildings)Sqm339.1339.12585.7FalseNoneNoneFalseNoneFalse876810.870
3758931141261NoneCDS-1, Sl.No.:9Supplying and Stringing of Rabbit ACSR Conductor as per BESCOM Specification (Part-V, CDS-1, Sl.No.:9) Km65407.8265407.820.4FalseNoneNoneFalseNoneFalse26163.1280
3758841141261None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket Each191.16191.16200.0FalseNoneNoneFalseNoneFalse38232.00
3758727141261None9.31Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (P. No - 64, I. No - 9.31, S R 2023-24, Vol-2-For Buildings)Sqm2534.112534.11489.19FalseNoneNoneFalseNoneFalse1239661.27090
3758932141261NoneSl.No.:5Supplying and fixing of 4 pin cross arm as per BESCOM Specification (CDS-5, Sl.No.:5) Set582.96582.966.0FalseNoneNoneFalseNoneFalse3497.760
3758728141261None10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (P. No - 69, I. No - 10.2, S R 2023-24, Vol-2-For Buildings)m398.65398.65503.21FalseNoneNoneFalseNoneFalse200604.66650
3758842141261None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module Each369.34369.3470.0FalseNoneNoneFalseNoneFalse25853.80
3758933141261NoneSl.No.:5Supplying and fixing of 2 pin cross arm as per BESCOM Specification (CDS-10, Sl.No.:5) Set417.96417.966.0FalseNoneNoneFalseNoneFalse2507.760
3758843141261None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Bell Push Each187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3758729141261None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (P. No - 60, I. No - 9.12.2, S R 2023-24, Vol-2-For Buildings)Sqm1391.631391.63412.49FalseNoneNoneFalseNoneFalse574033.45870
3758934141261NoneSl.No.:7Supplying of 1.1KV Pin Insulator as per BESCOM Specification (CDS-10, Sl.No.:7) No65.065.024.0FalseNoneNoneFalseNoneFalse1560.00
3758844141261None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Bell Push Each187.62187.622.0FalseNoneNoneFalseNoneFalse375.240
3758730141261None9.4Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge (P. No - 59, I. No - 9.4, S R 2023-24, Vol-1 - Common S R)Cum8101.868101.8668.0FalseNoneNoneFalseNoneFalse550926.480
3758935141261NoneSl.No.:8Supplying of No.8 Strain Insulator as per BESCOM Specification (CDS-10, Sl.No.:8) No25.025.012.0FalseNoneNoneFalseNoneFalse300.00
3758845141261None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket Each293.82293.8240.0FalseNoneNoneFalseNoneFalse11752.80
3758731141261None9.3.1Providing Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement :3 coarse sand), finished with a floating coat of neat cement. 18mm thick (P. No - 59, I. No - 9.3.1, S R 2023-24, Vol-1 - Common S R) Sqm585.82585.8259.52FalseNoneNoneFalseNoneFalse34868.00640
3758936141261NoneSl.No.:8Supplying and fixing of Spiral earth electrode as per BESCOM Specification (CDS-10, Sl.No.:8) No330.6330.66.0FalseNoneNoneFalseNoneFalse1983.60
3758846141261None3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket Each173.46173.464.0FalseNoneNoneFalseNoneFalse693.840
3758732141261None9.5Extra for making chequers of approved pattern on 1:2:4 cement concrete floors, steps, landing, pavements etc. (P. No - 59, I. No - 9.5, S R 2023-24, Vol-1 - Common S R)Sqm66.8566.85679.95FalseNoneNoneFalseNoneFalse45454.65750
3758847141261None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch Each442.5442.540.0FalseNoneNoneFalseNoneFalse17700.00
3758733141261None9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.(P. No - 60, I. No - 9.11, S R 2023-24, Vol-2-For Buildings)Sqm1080.491080.4989.99FalseNoneNoneFalseNoneFalse97233.29510
3758848141261None5.18.8Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 8 Way SP & N II - Double Door Each2000.12000.12.0FalseNoneNoneFalseNoneFalse4000.20
3758734141261None9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (P. No - 65, I. No - 9.39, S R 2023-24, Vol-2-For Buildings)Sqm1761.111761.11295.3FalseNoneNoneFalseNoneFalse520055.7830
3758849141261None5.18.9Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 12 Way SP & N II - Double Door Each2439.062439.064.0FalseNoneNoneFalseNoneFalse9756.240
3758735141261None9.40Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. (P. No - 65, I. No - 9.40, S R 2023-24, Vol-2-For Buildings)Sqm1132.751132.7515.0FalseNoneNoneFalseNoneFalse16991.250
3758736141261None11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P. No - 85, I. No - 11.28, S R 2023-24, Vol-2-For Buildings)Kg686.7686.7319.0FalseNoneNoneFalseNoneFalse219057.30
3758850141261None5.18.11Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 4 Way TP & N III - Double Door Each3602.543602.549.0FalseNoneNoneFalseNoneFalse32422.860
3758851141261None5.17.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP Each617.14617.1440.0FalseNoneNoneFalseNoneFalse24685.60
3758737141261None7.1.1Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m² (P. No - 21, I. No - 7.1.1, S R 2023-24, Vol-2-For Buildings)Sqm1068.341068.3472.98FalseNoneNoneFalseNoneFalse77967.45320
3758738141261None11.16.1Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P. No - 82, I. No - 11.16.1, S R 2023-24, Vol-2-For Buildings)Kgs165.29165.29437.76FalseNoneNoneFalseNoneFalse72357.35040
3758852141261None5.17.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP Each1301.541301.5422.0FalseNoneNoneFalseNoneFalse28633.880
3758739141261None2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (P. No - 15, I. No - 2.1.4, S R 2023-24, Vol-1 - Common S R)Cum7556.147556.1438.77FalseNoneNoneFalseNoneFalse292951.54780
3758853141261None5.17.8Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A TPN Each2823.742823.7410.0FalseNoneNoneFalseNoneFalse28237.40
3758854141261None12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell Each282.02282.022.0FalseNoneNoneFalseNoneFalse564.040
3758740141261None8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (P. No - 50, I. No - 8.51, S R 2023-24, Vol-2-For Buildings)Sqm121.54121.545384.19FalseNoneNoneFalseNoneFalse654394.45260
3758855141261None11.14.1Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 2' Tube light fitting. Each254.88254.887.0FalseNoneNoneFalseNoneFalse1784.160
3758741141261None8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P. No - 48, I. No - 8.39, S R 2023-24, Vol-2-For Buildings)Sqm154.36154.365384.19FalseNoneNoneFalseNoneFalse831103.56840
3758856141261None11.14.2Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 4' Tube light fitting. Each382.32382.32100.0FalseNoneNoneFalseNoneFalse38232.00
3758742141261None8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P. No - 46, I. No - 8.32, S R 2023-24, Vol-2-For Buildings)Sqm189.6189.62585.7FalseNoneNoneFalseNoneFalse490248.720
3758857141261None11.10.1Supplying & fixing of Surface mounting type retrofit type -LED tube . W comprising of LED linear source with CCT 6500 degree K, CRI 70perc. efficacy GTS 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF GTS 0.95, power loss should STS 5perc of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V.BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 8W-10W (T8) Each245.44245.447.0FalseNoneNoneFalseNoneFalse1718.080
3758743141261None8.33.2Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P. No - 46, I. No - 8.33.2, S R 2023-24, Vol-2-For Buildings)Sqm167.73167.73222.18FalseNoneNoneFalseNoneFalse37266.25140
3758858141261None11.10.2Supplying & fixing of Surface mounting type retrofit type -LED tube . W comprising of LED linear source with CCT 6500 degree K, CRI 70perc. efficacy GTS 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF GTS 0.95, power loss should STS 5perc of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V.BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18W-20W (T8) Each352.82352.8280.0FalseNoneNoneFalseNoneFalse28225.60
3758744141261None8.33.3Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P. No - 47, I. No - 8.33.3, S R 2023-24, Vol-2-For Buildings)Sqm168.94168.94241.66FalseNoneNoneFalseNoneFalse40826.04040
3758859141261None11.11.5Supplying & fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIsmall70 . efficacy gretr 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF gretr0.95, power loss should smalr 5 of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 , Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12W, 6500KEach279.66279.6634.0FalseNoneNoneFalseNoneFalse9508.440
3758745141261None12.76.2Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 200x10mm (P. No - 107, I. No - 12.76.2, S R 2023-24, Vol-2-For Buildings)Nos425.39425.3966.0FalseNoneNoneFalseNoneFalse28075.740
3758860141261None12.46Supplying & Fixing of 70-150 W lamp holder 2 Pin No139.24139.2434.0FalseNoneNoneFalseNoneFalse4734.160
3758746141261None12.79.1Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm (P. No - 108, I. No - 12.79.1, S R 2023-24, Vol-2-For Buildings)Nos302.63302.6372.0FalseNoneNoneFalseNoneFalse21789.360
3758747141261None12.74.1Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm (P. No - 107, I. No - 12.74.1, S R 2023-24, Vol-2-For Buildings)No123.97123.97144.0FalseNoneNoneFalseNoneFalse17851.680
3758861141261None6.2.1Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) Each3536.463536.4610.0FalseNoneNoneFalseNoneFalse35364.60
3758748141261None12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (P. No - 105, I. No - 12.58, S R 2023-24, Vol-2-For Buildings)No145.85145.8536.0FalseNoneNoneFalseNoneFalse5250.60
3758862141261None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model Each2460.32460.330.0FalseNoneNoneFalseNoneFalse73809.00
3758749141261None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (P. No - 105, I. No - 12.60, S R 2023-24, Vol-2-For Buildings)No1278.61278.628.0FalseNoneNoneFalseNoneFalse35800.80
3758863141261None6.5.1Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. 300 mm Sweep Each3124.643124.641.0FalseNoneNoneFalseNoneFalse3124.640
3758864141261None11.8.4Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70 , maximum light intensity should be between 60 degrees to 70 degrees. CCT smalr 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire grtr IK08. Power Factorsmallr0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency grtr1301m/w, nominal CRI smalr75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 90 W No9176.869176.868.0FalseNoneNoneFalseNoneFalse73414.880
3758750141261None8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment (P. No - 43, I. No - 8.16.1, S R 2023-24, Vol-2-For Buildings)m41.3241.321000.0FalseNoneNoneFalseNoneFalse41320.00
3758865141261None13.1.2Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket 1x40/2x40 W fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clA, bolts, and nuts and wiring using suitable capacity wires. Using 32mm dia G.I.Pipe Each1064.361064.364.0FalseNoneNoneFalseNoneFalse4257.440
3758866141261None13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamp, bolts, nuts and wiring using suitable capacity wires. Each223.02223.028.0FalseNoneNoneFalseNoneFalse1784.160
3758867141261None13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Each191.16191.1631.0FalseNoneNoneFalseNoneFalse5925.960
3758868141261None13.12Extra length of GI pipe of class B 19mm dia for down rod. m204.14204.1460.0FalseNoneNoneFalseNoneFalse12248.40
3758869141261None13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. Each828.36828.3610.0FalseNoneNoneFalseNoneFalse8283.60
3758870141261None8.1Supplying and drawing UTP-CAT 6E LAN cable. m40.1240.121500.0FalseNoneNoneFalseNoneFalse60180.00
3758871141261None8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pair m22.4222.42900.0FalseNoneNoneFalseNoneFalse20178.00
3758872141261None8.4.3Supplying & Fixing of switch mounting rack with power manager & Cable manager. 9U with 450mm depth Each8904.288904.281.0FalseNoneNoneFalseNoneFalse8904.280
3758873141261None8.9.2Supplying fixing of Network Switches 24 Port Gigabyte (manageable) Each54342.5454342.541.0FalseNoneNoneFalseNoneFalse54342.540
3758874141261None8.10.1Supplying & fixing of I/O socket with back box Single I/O Each477.9477.946.0FalseNoneNoneFalseNoneFalse21983.40
3758875141261None8.12.5Supplying & Fixing of Patch panel for LAN cabling 24 Port 10/100/1000 patch panel Each9746.89746.81.0FalseNoneNoneFalseNoneFalse9746.80
3758876141261None8.11.1Supplying & Fixing of . ms Cat 6 Patch Cable - 1 m Each224.2224.246.0FalseNoneNoneFalseNoneFalse10313.20
3758877141261None6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries. Each5399.685399.683.0FalseNoneNoneFalseNoneFalse16199.040
3758878141261None9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS Each93422.9693422.961.0FalseNoneNoneFalseNoneFalse93422.960
3758879141261None9.2.5Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. 5 kVA OFF LINE UPS Each45619.9845619.981.0FalseNoneNoneFalseNoneFalse45619.980
3758880141261None9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150 AH capacity Each22934.4822934.483.0FalseNoneNoneFalseNoneFalse68803.440
3758881141261None5.7.5Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 200 A Each1486.81486.86.0FalseNoneNoneFalseNoneFalse8920.80
3758882141261None5.40.1Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Strips m2612.522612.529.0FalseNoneNoneFalseNoneFalse23512.680
3758883141261None5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 A Each1400.661400.661.0FalseNoneNoneFalseNoneFalse1400.660
3758884141261None5.11.4Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution) 200 A Each14261.4814261.481.0FalseNoneNoneFalseNoneFalse14261.480
3758885141261None13.18.2Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling. 100A to 250A TPST Each483.8483.81.0FalseNoneNoneFalseNoneFalse483.80
3758886141261None5.14.1Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100 A 25 kA - THREE Pole Each6656.386656.384.0FalseNoneNoneFalseNoneFalse26625.520
3758887141261None5.4.10Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 200 A 35 kA - FOUR Pole Each25121.0225121.022.0FalseNoneNoneFalseNoneFalse50242.040
3758888141261None5.20.4Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 63 A 4 pole Each3608.443608.441.0FalseNoneNoneFalseNoneFalse3608.440
3758889141261None5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. Each9812.889812.881.0FalseNoneNoneFalseNoneFalse9812.880
3758890141261None5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy Each9876.69876.61.0FalseNoneNoneFalseNoneFalse9876.60
3758891141261None5.36Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer Each892.08892.083.0FalseNoneNoneFalseNoneFalse2676.240
3758892141261None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. Each547.52547.523.0FalseNoneNoneFalseNoneFalse1642.560
3758893141261None5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG cm0.510.51100000.0FalseNoneNoneFalseNoneFalse51000.00
3758894141261None5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm m324.5324.55.0FalseNoneNoneFalseNoneFalse1622.50
3758895141261NoneCivilEarth Work in surface excavation for stripping, seating, of bund, Road way, by manula etc (Vol.1 page:80, Sl.No.1.1) Mtr82.682.670.0FalseNoneNoneFalseNoneFalse5782.00
3758896141261NoneCivilSupplying, laying and jointing HDPE Pipe of specified grade and conforming to IS 4984-2016 etc (All pages with photos, Page:150, Sl.No.1.5) HDPE Grade PE80-PN6.0, 125mm dia Mtr512.12512.1270.0FalseNoneNoneFalseNoneFalse35848.40
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17234597020000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17234597020000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17234597020000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17234597020000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17234597020000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17234597300000NoneNoneELIGIBILITYIncrease in GST shall not be paid in the extended period at contract for which the contractor alone is responsible for delay as determined by authority while granting is extension of timeNone
17234597450000NoneNoneELIGIBILITYAll the work as Maintained in the Bill of Quantity (BOQ) are including lead and lift charges loading and unloading charges labor charges all incidental charges hire charges of all machinery and equipment required for successful completion of work etc., complete. The work shall be executed as per standard technical specification and directions of Engineer in charge of the workNone
17234597570000NoneNoneELIGIBILITYThe tenderer shall accept all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and / or liable for those cost. The employer is not responsible for any delay in accessing E - Procurement Portal.None
17234597680000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt orders.None
17234597850000NoneNoneELIGIBILITYMaterials like bitumen,steel,cement etc.,required for the work shall be procured by the tenderer themselves and should got tested by the quality control authority before use on the workNone
17234597960000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner otherwise it will be rejected.None
17234598090000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the Executive Engineer reserves the right to verify the original documents before approval.None
17234598230000NoneNoneELIGIBILITYIf any, additional information required, the same may be obtained from the office of the Executive Engineer, PW, & IWTD,Ramanagara Spl. Division, Ramanagara during office hours on all working days. It may be noted that if any of the dates mentioned above happened to be a General Holiday , the next working day will be consideredNone
17234598360000NoneNoneELIGIBILITYThe employer reserves the rights to Reject or accept any or all the tenders without assigning any reasonsNone
17234598530000NoneNoneELIGIBILITYThe Tender processing fee shall not be refundable.None
17234598640000NoneNoneELIGIBILITYTenderer who qualifies in the technical bid only those tenderers financial bid will be openedNone
17234598750000NoneNoneELIGIBILITYEstimate rates are including 18 percentage GST as per Common SR 2023-24None
17240540870000NoneNoneELIGIBILITYAll the concrete items Rates are inclusive of form works.None
17240541040000NoneNoneELIGIBILITYConditional tenders are not accepted.None
17240541180000NoneNoneELIGIBILITYPerformance security- the successful tenderer shall furnish performance security deposit 5% of the APT within 20 days after approval of tender as per rule 29.5 of the tender clause 44 of the agreement in the form of cash or bankers cheque, DD pay order BG or NSCs duley pledge in the nature of EE,PWD, Special Division, RamanagaraNone
17240541320000NoneNoneELIGIBILITYThe Bidder should submit the Bid capacity compulsorily the details of balance work B value (works inhand and works for which tender submitted) should be submitted in the prescribed formatNone
17240541450000NoneNoneELIGIBILITYThe contractor should maintain the work during the defect liability period 5thet is one year after the completion of work at his own costNone
17240541640000NoneNoneELIGIBILITYContractor should be registered with KPWD class 2 and above.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneSatisfactorily completed as prime contractor, at least one similar nature of work value not less than Rs. 219.02 Lakhs. (Building Civil Work)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- work done Certificate from officer not below rank of Executive engineer
NoneNoneNoneNone1.Earth work Excavation & Embankment/Filling----4352.00 Cum 2.SSM /Solid concrete blocks/B.B.M---- 444.00 Cum 3.PCC/RCC----1092.00 Cum 4.TMT Steel----69.12 Tonne 5.All types Flooring/skirting,dadoing----1042.00 Sqm 6.Cement Plastering----6635.00 Sqm 7.Painting----6747.00 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- work done Certificate from officer not below rank of Executive engineer
NoneNoneNoneNoneSl.No. Machineries To be Own To be Own/Hire/Lease 1.Concrete Batch Mix Plant/ Rotovator of suitable Specification 1 0 2.Transit mixers 1 1 3.Excavator 1 1 4.Water Tanker 2 2 5.Pin Vibrator 2 2 6.Tipper 2 1 7.Plate Vibrator 1 1 8.Steel shuttering Sheets & jacks 900Sqm 900Sqm 9.Concrete mixer 1 1Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- PURCHASE INVOICES,BILLS,SALE DEED,HIRE/LEASE AGREEEMNT & RC ISSUED BY RTO etc.,
NoneNoneNoneNoneTenderer who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under: Assessed available tender capacity - (AXNX1.5 - B) where A -Maximum value of works executed in any one year during the last five years taking into account the completed as well as works in progress. N -Number of years prescribed for completion of the works for which tenders are invited.B - Value, at 2024-25 price level, of existing commitments and on-going works to be completed during the next 9 Months.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- work done and balance work done certificate issued by an officer not less than rank of EE/Equivalent
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2019-20,2020-21, 2021-22,2022-23,2023-24 (a)Achieved in at least two financial years a minimum financial turnover (in all classes of Civil Engineering Building construction works only of Rs. 876.04 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BALANCE SHEETS,PROFIT AND LOSS STATEMENT ISSUED BY AN REGISTERED CHARTERED ACCOUNTANT
NoneNoneNoneNoneliquid assets and /or availability of credit facilities of no less than Rs. 146.01 Lakhs (Credit lines/ letter of credit/ certificates from nationalized banks for meeting the fund requirement etc. in the format to be as prescribed belowFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BANKERS CERTIFICATE IN THE PRESCRIBED FORMAT ISSUED FROM AN NATIONALISED BANKS / SCHEDULED BANK
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate and balance sheet of last five years 2019-20 to 2023-24TrueTechnical Bid
PWD Contractor Registration CertificateTrueTechnical Bid
workdone certificate completed as prime contractorTrueTechnical Bid
quantity wise work done certificateTrueTechnical Bid
LINE OF CREDITTrueTechnical Bid
work done certificate license/ registration copy along with concent letter of water supply/ sanitary engineering worksTrueTechnical Bid
work done certificate license/ registration copy along with electrical workTrueTechnical Bid
Documents of machineriesTrueTechnical Bid
Details of ongoing works and work in handTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsRamanagaraKanakapuraKanakapuraKANAKAPURAHAROHALLINoneNoneNoneNoneNoneNone
BuildingsRamanagaraNoneKanakapuraKANAKAPURAWATER SUPPLY AND SANITARY WORKSNoneNoneNoneNoneNoneNone
BuildingsRamanagaraNoneKanakapuraKANAKAPURABORE WELLNoneNoneNoneNoneNoneNone
BuildingsRamanagaraKanakapuraKanakapuraKANAKAPURASUMP TANK, SEPTIK TANK & SOAK PITNoneNoneNoneNoneNoneNone
BuildingsRamanagaraKanakapuraKanakapuraKANAKAPURAelectrcal workNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1724056686000
version0
createdDateNone
modifiedDateNone
blockNumberEXECUTIVE ENGINEER OFFICE PWD SPECIAL DIVISION RAMANAGARA
streetNone
citychannapatna
stateKarnataka
pin562160
tenderRecallDTONone