| 1723536466000 | 0 | None | None | Buildings | Construction of Toilet blocks at Police training centre Vijayapur. (Continue Work) (General Fund) | 657611.21 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3765994 | 141760 | None | 10.2.10, 114 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc.complete for: Pipes of SN 8, 160mm dia. | Mtr | 731.85 | 731.85 | 70.0 | False | None | None | False | None | False | 51229.5 | 0 | | 3765995 | 141760 | None | 16.9, 191 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover | Each | 5726.7 | 5726.7 | 25.0 | False | None | None | False | None | False | 143167.5 | 0 | | 3765996 | 141760 | None | 1.10, 7 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 168.0 | 168.0 | 6.0 | False | None | None | False | None | False | 1008.0 | 0 | | 3765997 | 141760 | None | 3.6, 16 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 | Cum | 517.65 | 517.65 | 60.0 | False | None | None | False | None | False | 31059.0 | 0 | | 3765998 | 141760 | None | 13.31.3, 122 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes | Mtr | 333.9 | 333.9 | 50.0 | False | None | None | False | None | False | 16695.0 | 0 | | 3765999 | 141760 | None | 13.5.3, 117 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore | No. | 348.6 | 348.6 | 6.0 | False | None | None | False | None | False | 2091.6 | 0 | | 3766000 | 141760 | None | 9.34, 64 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1622.25 | 1622.25 | 50.0 | False | None | None | False | None | False | 81112.5 | 0 | | 3766001 | 141760 | None | 8.30, 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 516.9081 | False | None | None | False | None | False | 94439.10987 | 0 | | 3766002 | 141760 | None | As per Market Rate | Supply and Fixing tap for Bib Cock Brass tap 20mm | Each | 200.0 | 200.0 | 30.0 | False | None | None | False | None | False | 6000.0 | 0 | | 3766003 | 141760 | None | As per Market Rate | Electrification Work. | LS | 100000.0 | 100000.0 | 1.0 | False | None | None | False | None | False | 100000.0 | 0 | | 3766004 | 141760 | None | PWD SR volum- 2 I No-11.25.2 page no 84 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 142.8 | 142.8 | 293.25 | False | None | None | False | None | False | 41876.1 | 0 | | 3766005 | 141760 | None | PWD SR volum- 2 I No-13.34 page no 84 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | l | 9.45 | 9.45 | 4000.0 | False | None | None | False | None | False | 37800.0 | 0 | | 3766006 | 141760 | None | 16.40.1, 201 | Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, Providing and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. With Table Moulded Bricks & Medium Duty cover and frame.For 1.2m dia Constructing Table Moulded Bricks Machinehole 1.2 m internal dia. , 1.0 M depth & Medium duty SFRC cover & frame | Each | 25566.45 | 25566.45 | 2.0 | False | None | None | False | None | False | 51132.9 | 0 |
|