3827451 | 145787 | None | code01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as perdrawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.SRP- Vol-I (8/1.14.1) Depth exceeding 1.5 m, but not exceeding 3 m.In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 46.85 | False | None | None | False | None | False | 5017.635 | 0 |
3827452 | 145787 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances requiredcomplete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately).SRP- Vol-I (15/2.1.2) Mix 1.4.8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 5.55 | False | None | None | False | None | False | 33006.96 | 0 |
3827453 | 145787 | None | code03 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.SRP- Vol-I (7/1.9) | Cum | 279.3 | 279.3 | 23.42 | False | None | None | False | None | False | 6541.206 | 0 |
3827454 | 145787 | None | code04 | KSRB 2.3 . Filling (new earth )Refilling available earth around trenches/pipelines, cables in layersnot exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m .Including cost of all labour complete as per specifications.SRP- Vol-I (7/1.10) SRP A-39/36 ( without Royalty ) | Cum | 441.0 | 441.0 | 14.24 | False | None | None | False | None | False | 6279.84 | 0 |
3827455 | 145787 | None | code05 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (17/2.4.1) Mix 1.2.4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6724.2 | 6724.2 | 0.74 | False | None | None | False | None | False | 4975.908 | 0 |
3827456 | 145787 | None | code06 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.1) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/1 (Foundation upto plinth (a) Isolated) | Cum | 7185.02 | 7185.02 | 4.41 | False | None | None | False | None | False | 31685.9382 | 0 |
3827457 | 145787 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/8 (Column) ( Corrigendum-3) | Cum | 12214.76 | 12214.76 | 3.62 | False | None | None | False | None | False | 44217.4312 | 0 |
3827458 | 145787 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/8 (Plinth beams of Building as per corrigendum-3) | Cum | 10777.72 | 10777.72 | 2.17 | False | None | None | False | None | False | 23387.6524 | 0 |
3827459 | 145787 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/12 (Beam & Lintal of Building) ( Corrigendum-3) | Cum | 11496.24 | 11496.24 | 3.04 | False | None | None | False | None | False | 34948.5696 | 0 |
3827460 | 145787 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 116/13 (Roof (Straight & Arched) ( Corrigendum-3) | Cum | 10777.72 | 10777.72 | 3.23 | False | None | None | False | None | False | 34812.0356 | 0 |
3827461 | 145787 | None | code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 116/20 (Chejjas,canopy & other Arch Projection of minor section) | Cum | 10418.47 | 10418.47 | 0.2 | False | None | None | False | None | False | 2083.694 | 0 |
3827462 | 145787 | None | code12 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SRP- Vol-II (84/11.32) | Kg | 93.92 | 93.92 | 1444.12 | False | None | None | False | None | False | 135631.7504 | 0 |
3827463 | 145787 | None | code13 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot ressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification.SRP- Vol-II (106/12.57.5) 35 mm thick one side teak and one side commercial | Sqm | 4758.6 | 4758.6 | 3.78 | False | None | None | False | None | False | 17987.508 | 0 |
3827464 | 145787 | None | code14 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.SRP- Vol-II (100/12.12) | Cum | 130412.1 | 130412.1 | 0.11 | False | None | None | False | None | False | 14345.331 | 0 |
3827465 | 145787 | None | code15 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. SRP- Vol-II (105/12.54) | Rmtr | 333.9 | 333.9 | 11.4 | False | None | None | False | None | False | 3806.46 | 0 |
3827466 | 145787 | None | code16 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.SRP- Vol-II (106/12.55.2) with one side prelam. | Sqm | 2452.8 | 2452.8 | 3.15 | False | None | None | False | None | False | 7726.32 | 0 |
3827467 | 145787 | None | code17 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SRP- Vol-II (85/34A) | Kg | 176.4 | 176.4 | 57.96 | False | None | None | False | None | False | 10224.144 | 0 |
3827468 | 145787 | None | code18 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1.6 (1 cement . 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.SRP- Vol-II (14/6.8) | Cum | 8367.45 | 8367.45 | 16.8 | False | None | None | False | None | False | 140573.16 | 0 |
3827469 | 145787 | None | code19 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix .1.4 (1 cement. 4 Fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.1) | Sqm | 309.75 | 309.75 | 123.2 | False | None | None | False | None | False | 38161.2 | 0 |
3827470 | 145787 | None | code20 | Providing 12 mm cement plaster with cement mortar 1.4 (1 cement.4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.1.2) | Sqm | 267.75 | 267.75 | 55.5 | False | None | None | False | None | False | 14860.125 | 0 |
3827471 | 145787 | None | code21 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1.6, 20 mm thick, and joints finished with cement mortar 1.3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. SRP- Vol-II (64/9.30) | Sqm | 5594.4 | 5594.4 | 2.25 | False | None | None | False | None | False | 12587.4 | 0 |
3827472 | 145787 | None | code22 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-charge. SRP- Vol-II (69/10.2) | Rmtr | 344.4 | 344.4 | 4.5 | False | None | None | False | None | False | 1549.8 | 0 |
3827473 | 145787 | None | code23 | Constructing brick maconary inspection chamber of internal dimention 600 X 450 mm, and depth of 600mm ( Inner dimension ) with modular bricks of class designation 75 in Cm 1.6 bed concrete 150mm thick with 1.3.6 with plastering 12 mm thick with CM 1.4.CC 1.2.4 cooping 75mm thick for fixing CI cover & frame etc.(excluding cost of CI frame & cover). SRP- Vol-V 16.9/191 | Each | 5030.55 | 5030.55 | 4.0 | False | None | None | False | None | False | 20122.2 | 0 |
3827474 | 145787 | None | code24 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will makehis own arrangements for procuring water for testing) etc.Note. Upto 110mm dia Coil shall be used. SRP- Vol-V 94/9.1.4 | Rmtr | 492.45 | 492.45 | 30.0 | False | None | None | False | None | False | 14773.5 | 0 |
3827475 | 145787 | None | code25 | Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651.1992,IS 4127 with latest amendments, including conveying to work site,caulking with hemp dipped in tar and jointing with CM 1.1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing.150 mm dia. pipes SRP- Vol-V 184/2.2/T040B | Rmtr | 610.05 | 610.05 | 10.0 | False | None | None | False | None | False | 6100.5 | 0 |
3827476 | 145787 | None | code26 | Providing and placing on terrace ( at all floor levels ) polyethylene water storage tanks,IS . 12701 marked,with cover and suitable locking arrangement and making necessary holes for for inlet,oulet and overflow pipes but without fittings and the base support for tank. SRP- Vol-II (12/13.34) | Ltr | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 |
3827477 | 145787 | None | code27 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP- Vol-II (11/13.33.6) 40 mm | Mtr | 500.85 | 500.85 | 40.0 | False | None | None | False | None | False | 20034.0 | 0 |
3827478 | 145787 | None | code28 | 25 mm | Mtr | 310.8 | 310.8 | 30.0 | False | None | None | False | None | False | 9324.0 | 0 |
3827479 | 145787 | None | code29 | 20 mm | Mtr | 227.85 | 227.85 | 25.0 | False | None | None | False | None | False | 5696.25 | 0 |
3827480 | 145787 | None | code30 | 15 mm | Mtr | 174.3 | 174.3 | 20.0 | False | None | None | False | None | False | 3486.0 | 0 |
3827481 | 145787 | None | code31 | White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap SRP- Vol-II (125/14.7.7) | Nos | 2203.95 | 2203.95 | 2.0 | False | None | None | False | None | False | 4407.9 | 0 |
3827482 | 145787 | None | code32 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS . 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required SRP- Vol-II (123/14.1.1)White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. | Nos | 5128.2 | 5128.2 | 2.0 | False | None | None | False | None | False | 10256.4 | 0 |
3827483 | 145787 | None | code33 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and makinggood the walls and floors wherever required One urinal basin with 5 litre white P.V.C. automatic flushing cistern SRP- Vol-II (123/14.4.1) | Each | 4676.7 | 4676.7 | 3.0 | False | None | None | False | None | False | 14030.1 | 0 |
3827484 | 145787 | None | code34 | Providing and fixing white vitreous china water closet squatting pan (Indian type) Long pattern W.C. pan of size 580 mm SRP- Vol-II (126/14.13.1) | Each | 1499.4 | 1499.4 | 3.0 | False | None | None | False | None | False | 4498.2 | 0 |
3827485 | 145787 | None | code35 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing . SRP- Vol-II (128/14.32.3) | Unit | 1119.3 | 1119.3 | 2.0 | False | None | None | False | None | False | 2238.6 | 0 |
3827486 | 145787 | None | code36 | Providing and fixing C I Nahani trap of approved make confirming to ISI specifications and construction of cistern in CC 1.2.4 as per directions (Inclusive of cost of materials and fixtures) 12.5 cms x 7.5 cms SRP 90 / 12.113.2 | Each | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 |
3827487 | 145787 | None | code37 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. 15 mm nominal bore SRP- Vol-II (117/13.5.1) | Nos | 310.8 | 310.8 | 6.0 | False | None | None | False | None | False | 1864.8 | 0 |
3827488 | 145787 | None | code38 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 40 mm nominal bore SRP- Vol-II (117/13.4.3) | Nos | 737.1 | 737.1 | 3.0 | False | None | None | False | None | False | 2211.3 | 0 |
3827489 | 145787 | None | code39 | Providing and fixing brass stop cock of approved quality 15 mm nominal bore SRP- Vol-II (117/13.3.1) | Nos | 313.95 | 313.95 | 5.0 | False | None | None | False | None | False | 1569.75 | 0 |
3827490 | 145787 | None | code40 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS . 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1.4 (1 Cement . 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. SRP- Vol-II (60/9.11) | Sqm | 933.45 | 933.45 | 11.04 | False | None | None | False | None | False | 10305.288 | 0 |
3827491 | 145787 | None | code41 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1.3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. SRP- Vol-II (65/9.38) | Sqm | 1461.6 | 1461.6 | 11.85 | False | None | None | False | None | False | 17319.96 | 0 |
3827492 | 145787 | None | code42 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1.6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab,including cost of materials,labour,curing, polishing complete as per specifications.SRP- Vol-II (64/9.34) | Sqm | 1622.25 | 1622.25 | 6.48 | False | None | None | False | None | False | 10512.18 | 0 |
3827493 | 145787 | None | Elecl code43 | SRP.1.2 Concealed Conduit SystemSupplying heavy gauge PVC conduit pipe 25 mm dia 2 .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick 1.2.2 | Mtr | 81.9 | 81.9 | 60.0 | False | None | None | False | None | False | 4914.0 | 0 |
3827494 | 145787 | None | Elecl code44 | SRP. 1.3.2 -Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick | Mtr | 82.95 | 82.95 | 30.0 | False | None | None | False | None | False | 2488.5 | 0 |
3827495 | 145787 | None | Elecl code45 | 1.1.2 Open Conduit System.Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structureor rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thick | Mtr | 85.05 | 85.05 | 50.0 | False | None | None | False | None | False | 4252.5 | 0 |
3827496 | 145787 | None | Elecl code46 | SRP.2.3.Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694.confirming to latest amendments. 1.5 sqmm 2.3.2 | Mtr | 27.3 | 27.3 | 200.45 | False | None | None | False | None | False | 5472.285 | 0 |
3827497 | 145787 | None | Elecl code47 | Do- 2.5 sqmm (P6/2.3.3) | Mtr | 44.1 | 44.1 | 120.0 | False | None | None | False | None | False | 5292.0 | 0 |
3827498 | 145787 | None | Elecl code48 | Do- 4 sqmm (P6/2.3.4) | Mtr | 66.15 | 66.15 | 40.0 | False | None | None | False | None | False | 2646.0 | 0 |
3827499 | 145787 | None | Elecl code49 | SRP.2.2.1.Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694. and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch box | No | 282.45 | 282.45 | 3.0 | False | None | None | False | None | False | 847.35 | 0 |
3827500 | 145787 | None | Elecl code50 | Do- Medium point above 3 Mtr upto 6Mtr from tapping point to outlet via switch box. (P5/2.2.2) | No | 397.95 | 397.95 | 4.0 | False | None | None | False | None | False | 1591.8 | 0 |
3827501 | 145787 | None | Elecl code51 | Do- Long point above 6 Mtr upto 10Mtr from tapping point to outlet via switch box. (P5/2.2.3) | No | 582.75 | 582.75 | 6.0 | False | None | None | False | None | False | 3496.5 | 0 |
3827502 | 145787 | None | Elecl code52 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1-3Way 3.4.1 | No | 144.9 | 144.9 | 2.0 | False | None | None | False | None | False | 289.8 | 0 |
3827503 | 145787 | None | Elecl code53 | Do- 4-5way (P15/3.4.3) | No | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 |
3827504 | 145787 | None | Elecl code54 | Do-6 way (P15/3.4.4) | No | 231.0 | 231.0 | 1.0 | False | None | None | False | None | False | 231.0 | 0 |
3827505 | 145787 | None | Elecl code55 | Do-10-12 way (P15/3.4.6) | No | 334.95 | 334.95 | 2.0 | False | None | None | False | None | False | 669.9 | 0 |
3827506 | 145787 | None | Elecl code56 | Do-18 way (P15/3.4.8) | No | 425.25 | 425.25 | 1.0 | False | None | None | False | None | False | 425.25 | 0 |
3827507 | 145787 | None | Elecl code57 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module 3.5.1 | No | 143.85 | 143.85 | 2.0 | False | None | None | False | None | False | 287.7 | 0 |
3827508 | 145787 | None | Elecl code58 | Do- 4 mod (P16/3.5.3) | No | 183.75 | 183.75 | 1.0 | False | None | None | False | None | False | 183.75 | 0 |
3827509 | 145787 | None | Elecl code59 | Do- 6 Module (P16/3.5.4) | No | 245.7 | 245.7 | 1.0 | False | None | None | False | None | False | 245.7 | 0 |
3827510 | 145787 | None | Elecl code60 | Do-10-12 Module (P16/3.5.6) | No | 361.2 | 361.2 | 2.0 | False | None | None | False | None | False | 722.4 | 0 |
3827511 | 145787 | None | Elecl code61 | Do-18 Module (P16/3.5.8) | No | 479.85 | 479.85 | 1.0 | False | None | None | False | None | False | 479.85 | 0 |
3827512 | 145787 | None | Elecl code62 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch 3.6.1 | No | 107.1 | 107.1 | 12.0 | False | None | None | False | None | False | 1285.2 | 0 |
3827513 | 145787 | None | Elecl code63 | Do- 6Amps 3 way socket (P16/3.6.3) | No | 179.55 | 179.55 | 3.0 | False | None | None | False | None | False | 538.65 | 0 |
3827514 | 145787 | None | Elecl code64 | Do- modular stepped fan regulator (P16/3.6.4) | No | 374.85 | 374.85 | 1.0 | False | None | None | False | None | False | 374.85 | 0 |
3827515 | 145787 | None | Elecl code65 | Do- 16Amps one way switch (P16/3.6.7) | No | 189.0 | 189.0 | 1.0 | False | None | None | False | None | False | 189.0 | 0 |
3827516 | 145787 | None | Elecl code66 | Do- 6/16 Amps universal socket (P16/3.6.10) | No | 247.8 | 247.8 | 1.0 | False | None | None | False | None | False | 247.8 | 0 |
3827517 | 145787 | None | Elecl code67 | Supplying and fixing Fan box with round hook (P3/1.13) | No | 122.85 | 122.85 | 1.0 | False | None | None | False | None | False | 122.85 | 0 |
3827518 | 145787 | None | Elecl code68 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 25mm 1.9.2 | Mtr | 23.1 | 23.1 | 12.0 | False | None | None | False | None | False | 277.2 | 0 |
3827519 | 145787 | None | Elecl code69 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70percentage lumen maintenance with CRI more than 80. Power Input. 220-240V @ 50/60Hz & Power factor more than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.11.3.2 LED light fighting 1 x4- 20/22 w | No | 724.5 | 724.5 | 8.0 | False | None | None | False | None | False | 5796.0 | 0 |
3827520 | 145787 | None | Elecl code70 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.5.18.1 6-32Amps SP | No | 435.75 | 435.75 | 4.0 | False | None | None | False | None | False | 1743.0 | 0 |
3827521 | 145787 | None | Elecl code71 | Do- 6-32 Amps DP. (5.18.2) | No | 775.95 | 775.95 | 1.0 | False | None | None | False | None | False | 775.95 | 0 |
3827522 | 145787 | None | Elecl code72 | 11.2.1.Supplying & fixing retrofit type -PL- LED Lamp .......W LED linear source with CCT 6500 degree K, CRImore than 70percentage. efficacy more than80 lumen per watt, lifemore than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5percentage of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. | Each | 654.15 | 654.15 | 6.0 | False | None | None | False | None | False | 3924.9 | 0 |