3571506 | 129737 | None | code01 | Earth work in surface excavation for stripping, seating of bund, Road way by manual means for lowering & levelling the ground for all works other than foundation & depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. | Cum | 474.6 | 474.6 | 12.0 | False | None | None | False | None | False | 5695.2 | 0 |
3571507 | 129737 | None | code02 | Loading and Unloading of Stone Boulder/Stone aggregates/Sand/Kankar/Moorum. (Tipper 10m3). | Cum | 87.15 | 87.15 | 12.0 | False | None | None | False | None | False | 1045.8 | 0 |
3571508 | 129737 | None | code03 | Cost of Haulage Excluding Loading and Unloading Case-1 : Surfaced Road. A Taking output 10 t load and lead 10 km = 100 t.km. | T.Km | 12.6 | 12.6 | 18.0 | False | None | None | False | None | False | 226.8 | 0 |
3571509 | 129737 | None | code04 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 285.6 | 285.6 | 57.56 | False | None | None | False | None | False | 16439.136 | 0 |
3571510 | 129737 | None | code05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 5466.3 | 5466.3 | 4.77 | False | None | None | False | None | False | 26074.251 | 0 |
3571511 | 129737 | None | code06 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand). | Cum | 5820.15 | 5820.15 | 14.01 | False | None | None | False | None | False | 81540.3015 | 0 |
3571512 | 129737 | None | code07 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6615.84 | 6615.84 | 2.0025 | False | None | None | False | None | False | 13248.2196 | 0 |
3571513 | 129737 | None | code08 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 214.2 | 214.2 | 41.94 | False | None | None | False | None | False | 8983.548 | 0 |
3571514 | 129737 | None | code09 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1255.8 | 1255.8 | 14.4 | False | None | None | False | None | False | 18083.52 | 0 |
3571515 | 129737 | None | code10 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1114.05 | 1114.05 | 57.5 | False | None | None | False | None | False | 64057.875 | 0 |
3571516 | 129737 | None | code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately). M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7789.32 | 7789.32 | 3.7595 | False | None | None | False | None | False | 29283.94854 | 0 |
3571517 | 129737 | None | code12 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately). | Kg | 100.8 | 100.8 | 451.14 | False | None | None | False | None | False | 45474.912 | 0 |
3571518 | 129737 | None | code13 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 3843.0 | 3843.0 | 3.78 | False | None | None | False | None | False | 14526.54 | 0 |
3571519 | 129737 | None | code14 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 287.7 | 287.7 | 12.46 | False | None | None | False | None | False | 3584.742 | 0 |
3571520 | 129737 | None | code15 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 326.55 | 326.55 | 78.69 | False | None | None | False | None | False | 25696.2195 | 0 |
3571521 | 129737 | None | code16 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 322.35 | 322.35 | 76.0675 | False | None | None | False | None | False | 24520.358625 | 0 |
3571522 | 129737 | None | code17 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. | Sqm | 740.25 | 740.25 | 10.38 | False | None | None | False | None | False | 7683.795 | 0 |
3571523 | 129737 | None | code18 | Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge. | Cum | 6510.0 | 6510.0 | 0.12 | False | None | None | False | None | False | 781.2 | 0 |
3571524 | 129737 | None | code19 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge. | Cum | 1294.65 | 1294.65 | 9.9 | False | None | None | False | None | False | 12817.035 | 0 |
3571525 | 129737 | None | code20 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1022.7 | 1022.7 | 53.76 | False | None | None | False | None | False | 54980.352 | 0 |
3571526 | 129737 | None | code21 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Sqm | 498.75 | 498.75 | 5.04 | False | None | None | False | None | False | 2513.7 | 0 |
3571527 | 129737 | None | code22 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.-do- with both side prelam. | Sqm | 3993.15 | 3993.15 | 5.04 | False | None | None | False | None | False | 20125.476 | 0 |
3571528 | 129737 | None | code23 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5113.5 | 5113.5 | 2.16 | False | None | None | False | None | False | 11045.16 | 0 |
3571529 | 129737 | None | code24 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage andreinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mmx 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T and Ps shall not be made) | Sqm | 7602.0 | 7602.0 | 17.28 | False | None | None | False | None | False | 131362.56 | 0 |
3571530 | 129737 | None | code25 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 166.95 | 166.95 | 408.24 | False | None | None | False | None | False | 68155.668 | 0 |
3571531 | 129737 | None | code26 | Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. | Sqm | 19.95 | 19.95 | 37.39 | False | None | None | False | None | False | 745.9305 | 0 |
3571532 | 129737 | None | code27 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after horoughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 123.9 | 123.9 | 37.39 | False | None | None | False | None | False | 4632.621 | 0 |
3571533 | 129737 | None | code28 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 138.6 | 138.6 | 85.01 | False | None | None | False | None | False | 11782.386 | 0 |
3571534 | 129737 | None | code29 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 136.5 | 136.5 | 36.72 | False | None | None | False | None | False | 5012.28 | 0 |
3571535 | 129737 | None | code30 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. | Each | 1981.35 | 1981.35 | 1.0 | False | None | None | False | None | False | 1981.35 | 0 |
3571536 | 129737 | None | code31 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. | Kg | 477.75 | 477.75 | 360.0 | False | None | None | False | None | False | 171990.0 | 0 |
3571537 | 129737 | None | code32 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness (weight not less than 20 kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications. | Sqm | 1287.3 | 1287.3 | 24.0 | False | None | None | False | None | False | 30895.2 | 0 |
3571538 | 129737 | None | code33 | Providing and fixing of typical 'Citizen Information Board A" as per specifications and drawing. Two ACP Sheet of 4mm thick having minimum 0.25mm thick aluminum skin both sides and fixed over a back support of Ms plate of 5mm thick. Supported on frame post of 2 no's of MS Suare hallow section 75mmx75mmx6mm which is duly embedded in cement concrete M20 Grade of 600x600x750mm,600mm below ground level.All MS will be stove enameled on both the sides. All sections of framed posts,MS sheet and Stell tubes will be painted with primer and two coats of epoxy paint as per drawing etc..Retro-Reflective Sheet as per IRC 67 fixted over a two no's of Aluminum composite material(ACP) sheeting of size 900x750mm of 4mm thick duly bolted/reveted with MS plate of 5mm thick on backside of ACP Sheet.Including cost and conveyance of all materials,equipment,machinery and labour with all leads and lifts,loading charges charges necessary for satisfactory completion of work as per directed by engineer incharge | No | 22614.9 | 22614.9 | 1.0 | False | None | None | False | None | False | 22614.9 | 0 |
3571539 | 129737 | None | code34 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. | Each | 4458.3 | 4458.3 | 2.0 | False | None | None | False | None | False | 8916.6 | 0 |
3571540 | 129737 | None | code35 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. | Each | 3778.95 | 3778.95 | 2.0 | False | None | None | False | None | False | 7557.9 | 0 |
3571541 | 129737 | None | code36 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Each | 4592.7 | 4592.7 | 5.0 | False | None | None | False | None | False | 22963.5 | 0 |
3571542 | 129737 | None | code37 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 32mm dia., 10 kg/sqcm & class 5. | Mtr | 84.67 | 84.67 | 50.0 | False | None | None | False | None | False | 4233.5 | 0 |
3571543 | 129737 | None | code38 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 160mm dia. | Mtr | 583.8 | 583.8 | 50.0 | False | None | None | False | None | False | 29190.0 | 0 |
3571544 | 129737 | None | code39 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 :HDPE Grade PE80-PN6.0, 90mm dia. | Mtr | 249.9 | 249.9 | 6.0 | False | None | None | False | None | False | 1499.4 | 0 |
3571545 | 129737 | None | code40 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments.32mm dia PVC couplers | Each | 17.85 | 17.85 | 5.0 | False | None | None | False | None | False | 89.25 | 0 |
3571546 | 129737 | None | code41 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.32 mm dia PVC Elbows. | Each | 23.1 | 23.1 | 10.0 | False | None | None | False | None | False | 231.0 | 0 |
3571547 | 129737 | None | code42 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.32 mm dia PVC Tee. | Each | 34.65 | 34.65 | 5.0 | False | None | None | False | None | False | 173.25 | 0 |
3571548 | 129737 | None | code43 | Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.32 mm dia PVC BEND. | Each | 39.9 | 39.9 | 10.0 | False | None | None | False | None | False | 399.0 | 0 |
3571549 | 129737 | None | code44 | Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 1000 litre capacity) | No | 7169.4 | 7169.4 | 1.0 | False | None | None | False | None | False | 7169.4 | 0 |
3571550 | 129737 | None | code45 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore. | No | 605.85 | 605.85 | 4.0 | False | None | None | False | None | False | 2423.4 | 0 |
3571551 | 129737 | None | code46 | Providing and fixing brass stop cock of approved quality : 20 mm nominal bore. | No | 362.25 | 362.25 | 5.0 | False | None | None | False | None | False | 1811.25 | 0 |
3571552 | 129737 | None | code47 | Providing and fixing brass bib cock of approved quality.20 mm nominal bore. | No | 362.25 | 362.25 | 5.0 | False | None | None | False | None | False | 1811.25 | 0 |
3571553 | 129737 | None | code48 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm. | No | 1549.8 | 1549.8 | 2.0 | False | None | None | False | None | False | 3099.6 | 0 |
3571554 | 129737 | None | code49 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | No | 399.0 | 399.0 | 5.0 | False | None | None | False | None | False | 1995.0 | 0 |
3571555 | 129737 | None | code50 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. | No | 1004.85 | 1004.85 | 5.0 | False | None | None | False | None | False | 5024.25 | 0 |
3571556 | 129737 | None | code51 | Concealed Conduit System Supplying heavy PVC condiuit pipe ……mm dia ......mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick | Mtr | 70.0 | 70.0 | 25.0 | False | None | None | False | None | False | 1750.0 | 0 |
3571557 | 129737 | None | code52 | Concealed Conduit System Supplying heavy gauge PVC Conduit Pipe ….dia …..mm thick with suitable size bends, metal junction boxes adhesive paste etx., by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick | Mtr | 80.0 | 80.0 | 25.0 | False | None | None | False | None | False | 2000.0 | 0 |
3571558 | 129737 | None | code53 | Supplying and fixing PVC/metal conduit accessories.------deep junction box 25mm junction box | Each | 51.0 | 51.0 | 10.0 | False | None | None | False | None | False | 510.0 | 0 |
3571559 | 129737 | None | code54 | Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ------6Way | Each | 212.0 | 212.0 | 2.0 | False | None | None | False | None | False | 424.0 | 0 |
3571560 | 129737 | None | code55 | Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ----- 8Way | Each | 250.0 | 250.0 | 2.0 | False | None | None | False | None | False | 500.0 | 0 |
3571561 | 129737 | None | code56 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.----- 6Moudule | Each | 244.0 | 244.0 | 2.0 | False | None | None | False | None | False | 488.0 | 0 |
3571562 | 129737 | None | code57 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box------ 8Moudule | Each | 302.0 | 302.0 | 2.0 | False | None | None | False | None | False | 604.0 | 0 |
3571563 | 129737 | None | code58 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. ----- Using Group "A" materials 6Amps one way. | Each | 88.0 | 88.0 | 10.0 | False | None | None | False | None | False | 880.0 | 0 |
3571564 | 129737 | None | code59 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. ----- Using Group "A" materials 6Amps 3way socket. | Each | 162.0 | 162.0 | 5.0 | False | None | None | False | None | False | 810.0 | 0 |
3571565 | 129737 | None | code60 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. ------- Using Group "A" materials 32Amps DP switch | Each | 375.0 | 375.0 | 2.0 | False | None | None | False | None | False | 750.0 | 0 |
3571566 | 129737 | None | code61 | Supplying PVC/Gi Flexible conduit pipe.. Mm dia fxing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddies at an interval of 300mm using NF screws on the either end of the pipe terminated completely.----- 25mm | Mtr | 31.0 | 31.0 | 10.0 | False | None | None | False | None | False | 310.0 | 0 |
3571567 | 129737 | None | code62 | Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet.----- Short point up to 3Mtr from tapping point to out let via switch | Point | 251.0 | 251.0 | 6.0 | False | None | None | False | None | False | 1506.0 | 0 |
3571568 | 129737 | None | code63 | Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet.-----Medium point above 3mtr up to 6Mtr from tapping point to out let via switch | Point | 361.0 | 361.0 | 6.0 | False | None | None | False | None | False | 2166.0 | 0 |
3571569 | 129737 | None | code64 | Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet.------ Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box | Point | 542.0 | 542.0 | 6.0 | False | None | None | False | None | False | 3252.0 | 0 |
3571570 | 129737 | None | code65 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. ----- GTP of GROUP-a 1.5 sqmm | Mtr | 26.0 | 26.0 | 50.0 | False | None | None | False | None | False | 1300.0 | 0 |
3571571 | 129737 | None | code66 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. ------ GTP of GROUP-a 2.5 sqmm | Mtr | 40.0 | 40.0 | 50.0 | False | None | None | False | None | False | 2000.0 | 0 |
3571572 | 129737 | None | code67 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. -----4 sqmm | Mtr | 59.0 | 59.0 | 50.0 | False | None | None | False | None | False | 2950.0 | 0 |
3571573 | 129737 | None | code68 | Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screws.------ 80mm | Nos | 10.0 | 10.0 | 10.0 | False | None | None | False | None | False | 100.0 | 0 |
3571574 | 129737 | None | code69 | Supplying of . feet - LED PVC Square Batten .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50Hz & Power factor greater than 0.9 along with CE approved. 5 years Warranty against any manufacturing defect working under standard electrical condition -LED light fighting 2'- 9/10 w | Each | 496.0 | 496.0 | 8.0 | False | None | None | False | None | False | 3968.0 | 0 |
3571575 | 129737 | None | code70 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. ------6-32 Amps DP | Each | 523.0 | 523.0 | 1.0 | False | None | None | False | None | False | 523.0 | 0 |
3571576 | 129737 | None | code71 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. ------ 50-63Amps TNP | Each | 2393.0 | 2393.0 | 1.0 | False | None | None | False | None | False | 2393.0 | 0 |
3571577 | 129737 | None | code72 | Supplying fixing and wiring Earth Leakage Miniature Circuit Breaker ELMCB 240/450V upto 300mA sensitvity on existing wood/panel 32 - 40 Amps 4 pole | Each | 2826.0 | 2826.0 | 1.0 | False | None | None | False | None | False | 2826.0 | 0 |
3571578 | 129737 | None | code73 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Nos | 4150.0 | 4150.0 | 1.0 | False | None | None | False | None | False | 4150.0 | 0 |
3571579 | 129737 | None | code74 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. ------GI strip 25x3mm | Mtr | 75.0 | 75.0 | 2.0 | False | None | None | False | None | False | 150.0 | 0 |
3571580 | 129737 | None | code75 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with suitable approved colour powder coated paint.-------18SWG | Sq CM | 0.3 | 0.3 | 10000.0 | False | None | None | False | None | False | 3000.0 | 0 |
3571581 | 129737 | None | code76 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers etc., complete.------100Amps 4x30x6mm Alluminium Strips | Mtr | 2050.0 | 2050.0 | 1.0 | False | None | None | False | None | False | 2050.0 | 0 |
3571582 | 129737 | None | code77 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers..----- 63Amps | Each | 227.0 | 227.0 | 2.0 | False | None | None | False | None | False | 454.0 | 0 |
3571583 | 129737 | None | code78 | Supplying of 1.1 KV LT UG cable having aluminium conductor PVC insulated, extruded inner sheathed,galvanised,steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 & confirming to the attached GTP of GROUP-A. ------4 core 16 sqmm | Mtr | 150.0 | 150.0 | 40.0 | False | None | None | False | None | False | 6000.0 | 0 |
3571584 | 129737 | None | code79 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.-------In exixting trench/duct. 6 sqmm to 16 sqmm | Mtr | 11.88 | 11.88 | 20.0 | False | None | None | False | None | False | 237.6 | 0 |
3571585 | 129737 | None | code80 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.-----On wall /Structure. 6 sqmm to 16 sqmm | Mtr | 30.0 | 30.0 | 20.0 | False | None | None | False | None | False | 600.0 | 0 |
3571586 | 129737 | None | code81 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.----)In soil (hard) | Mtr | 102.0 | 102.0 | 20.0 | False | None | None | False | None | False | 2040.0 | 0 |
3571587 | 129737 | None | code82 | Supplying and fixing of class A (medium duty) GI pipe of wall thick ness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class.---40mm | Mtr | 335.0 | 335.0 | 20.0 | False | None | None | False | None | False | 6700.0 | 0 |
3571588 | 129737 | None | code83 | Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments------.0.50 HP/0.37kW - 5 STG(stage) | Each | 10762.5 | 10762.5 | 1.0 | False | None | None | False | None | False | 10762.5 | 0 |
3571589 | 129737 | None | code84 | KEB Permission charges and Meter Charges | LS | 20000.0 | 20000.0 | 1.0 | False | None | None | False | None | False | 20000.0 | 0 |