createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1724230245097
version11
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd509500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose29-08-2024 16:00:00
tenderQueryClose26-08-2024 17:30:00
technicalBidOpen30-08-2024 16:30:00
publishedDate21-08-2024 17:28:45
publishedByPostPWD_EE_DIV_SED
publishedByUserKPE14118 - DASHWANTH L GAJRE
bidValidityPeriod90
noOfCalls2
preBidMeetingDate23-08-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonSRI SHEKHAPPA TAMDADDI
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08441276278
mobileNumber9901098011
tenderSupplierListNone
tenderSchedule
createdTs1724230245100
version12
createdDateNone
modifiedDateNone
tenderNumberPWD/2024-25/BD/WORK_INDENT11999/CALL-2
titleCONSTRUCTION OF GOVERNMENT PRE UNIVERSITY COLLEGE AT CHITTAPUR TOWN IN KALABURAGI DISTRICT UNDER KKRDB MICRO (SOCIAL) FOR THE YEAR 2023-24 (WORKCODE KLB2392331574)
descriptionCONSTRUCTION OF GOVERNMENT PRE UNIVERSITY COLLEGE AT CHITTAPUR TOWN IN KALABURAGI DISTRICT UNDER KKRDB MICRO (SOCIAL) FOR THE YEAR 2023-24 (WORKCODE KLB2392331574)
categoryWORKS
categoryTextWorks
ecv33965392.18
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1690
locationNamePWD Division Office Sedam
provisionalAmount40080000.0
groupOverheadTotal0.0
fileNumberPWD/SD/CHIT/KKRDB/2024-25/2
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17242302450000NoneNoneBuildingsDISMANTLING1360587.63
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3826858145761NoneVol-II I No 19.3 Page No 187Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum2547.32547.3384.99FalseNoneNoneFalseNoneFalse980685.0270
3826859145761NoneVol-II I No 19.7.3 Page No 187Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortarCum1080.451080.45291.76FalseNoneNoneFalseNoneFalse315232.0920
3826860145761NoneVol-II I No 19.12.2 Page No 188Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge. Of area beyond 3 m²Sqm275.1275.1235.08FalseNoneNoneFalseNoneFalse64670.5080
17242302450001NoneNoneBuildingsGROUND FLOOR32078610.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3826861145762NoneVol-III I No. 2.5 (ii) a Page No 9Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle100 Sqm412.65412.6592.82FalseNoneNoneFalseNoneFalse38302.1730
3826862145762NoneVol-I I no. 1.12 Page no 8Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum99.7599.753276.0FalseNoneNoneFalseNoneFalse326781.00
3826863145762NoneVol-II I No 4.1 Page No 4Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm123.9123.91892.0FalseNoneNoneFalseNoneFalse234418.80
3826864145762NoneVol-I I no 1.14.1 Page No 8Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum107.1107.1874.21FalseNoneNoneFalseNoneFalse93627.8910
3826865145762NoneVol-I I no 1.15.1 Page No 8Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depthCum381.15381.1597.13FalseNoneNoneFalseNoneFalse37021.09950
3826866145762NoneVol-I I No 2.1.3 Page No 15Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.45259.23FalseNoneNoneFalseNoneFalse1630154.89350
3826867145762NoneVol-II I no 6.32 Page No 17Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.52.4FalseNoneNoneFalseNoneFalse3301.20
3826868145762NoneVol-I I No 1.9 Page No 7Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.3457.03FalseNoneNoneFalseNoneFalse127648.4790
3826869145762NoneVol-I I no 1.8 Page no 7Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum497.7497.72838.0FalseNoneNoneFalseNoneFalse1412472.60
3826870145762NoneVol-I I No 2.2.3 Page No 15Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6652.86652.8306.9FalseNoneNoneFalseNoneFalse2041744.320
3826871145762NoneVol-I S R Sl no 1 a Page No 111Addendum I-Percentage Additionalities for Formwork, Centering & Scaffolding for Foundation upto Plinth Isolated add 8%Cum532.22532.22306.9FalseNoneNoneFalseNoneFalse163338.3180
3826872145762NoneVol-I I No 2.4.3 Page No 16Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6652.86652.817.93FalseNoneNoneFalseNoneFalse119284.7040
3826873145762NoneVol-I S R Sl no 9 Page No 111Addendum I-Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) add 70%Cum4656.964656.9617.93FalseNoneNoneFalseNoneFalse83499.29280
3826874145762NoneVol-I I No 2.3.2 Page No 16Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6804.06804.096.96FalseNoneNoneFalseNoneFalse659715.840
3826875145762NoneVol-I S R Sl No 2 Page No 111Addendum I-Percentage Additionalities for Formwork, Centering & Scaffolding for Plinth Beams of Buildings add 50%Cum3402.03402.096.96FalseNoneNoneFalseNoneFalse329857.920
3826876145762NoneVol-I I No 2.1.4 Page No 15Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.858.94FalseNoneNoneFalseNoneFalse58358.9790
3826877145762NoneVol-I I No 2.11 a Page No 18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildingst93929.8593929.8539.06FalseNoneNoneFalseNoneFalse3668899.9410
3826878145762NoneVol-I I No 2.5.2 Page No 16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.1530.8FalseNoneNoneFalseNoneFalse221302.620
3826879145762NoneVol-I S R Sl no 9 Page No 111Addendum I-Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) add 70%Cum5029.65029.630.8FalseNoneNoneFalseNoneFalse154911.680
3826880145762NoneVol-I I No 2.5.2 Page No 16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.1593.65FalseNoneNoneFalseNoneFalse672889.29750
3826881145762NoneVol-I S R Sl No 14 Page No 112Addendum I-Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts add 60%Cum4311.094311.0993.65FalseNoneNoneFalseNoneFalse403733.57850
3826882145762NoneVol-I I No 2.5.2 Page no 16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.15279.61FalseNoneNoneFalseNoneFalse2009039.79150
3826883145762NoneVOl-I S R Sl no 15 & 16 Page No 112Addendum I-Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs & Staircase and other similar structures add 50%Cum3592.573592.57279.61FalseNoneNoneFalseNoneFalse1004518.49770
3826884145762NoneVol-I I No 2.5.1 Page No 16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6961.56961.59.48FalseNoneNoneFalseNoneFalse65995.020
3826885145762NoneVol-I S R Sl no 19 Page No 112Addendum I-Percentage Additionalities for Formwork, Centering & Scaffolding Chejjas, Canopy & Other Architectural projections of minor sections add 45%Cum3132.673132.679.48FalseNoneNoneFalseNoneFalse29697.71160
3826886145762NoneVol-I I No 2.1.4 Page no 15Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.851.53FalseNoneNoneFalseNoneFalse9987.61050
3826887145762NoneVol-I I No 2.11 a Page no 18fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildingst93929.8593929.8543.5FalseNoneNoneFalseNoneFalse4085948.4750
3826888145762NoneVol-II I No 6.32 Page No 17Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.51787.51FalseNoneNoneFalseNoneFalse2458720.0050
3826889145762NoneVol-II I no 6.34 Page No 17Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1159.21159.240.85FalseNoneNoneFalseNoneFalse47353.320
3826890145762NoneVol-II I no 12.15 Page no 100Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.210.2FalseNoneNoneFalseNoneFalse79725.240
3826891145762NoneVol-II I No 12.13.1 Page No 100Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum103755.75103755.751.35FalseNoneNoneFalseNoneFalse140070.26250
3826892145762NoneVol-II I No 12.93.1 Page no 111Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mmm737.1737.137.1FalseNoneNoneFalseNoneFalse27346.410
3826893145762NoneVol-II I No 12.94.1 Page no 112Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thicknessSqm3659.253659.2511.02FalseNoneNoneFalseNoneFalse40324.9350
3826894145762NoneVol-II I no 11.34A Page no 86Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg176.4176.42755.62FalseNoneNoneFalseNoneFalse486091.3680
3826895145762NoneVol-II I No 8.2.1 Page No 41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.75309.752873.99FalseNoneNoneFalseNoneFalse890218.40250
3826896145762NoneVol-II I No 8.2.1 Page No 41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.75309.75797.74FalseNoneNoneFalseNoneFalse247099.9650
3826897145762NoneVol-II I No 9.24 Page No 63Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm2994.62994.62556.78FalseNoneNoneFalseNoneFalse7656533.3880
3826898145762NoneVol-II I no 8.16.2 Page no 43Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm widem39.939.91776.4FalseNoneNoneFalseNoneFalse70878.360
3826899145762NoneVol-II I No 9.25 page no 63Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.Sqm840.0840.049.0FalseNoneNoneFalseNoneFalse41160.00
3826900145762NoneVol-II I no 22.15.1 Page No 218Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Handles 200mmNo472.5472.532.0FalseNoneNoneFalseNoneFalse15120.00
3826901145762NoneVol-II I no 22.15.3 Page no 218Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia, 200mmNo315.0315.032.0FalseNoneNoneFalseNoneFalse10080.00
3826902145762NoneVol-II I No 22.15.5 Page No 219Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Tower Bolts 150x10mmNo126.0126.032.0FalseNoneNoneFalseNoneFalse4032.00
3826903145762NoneVol-II I no 22.15.8 Page no 219Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS hinges 125 mmNo52.552.596.0FalseNoneNoneFalseNoneFalse5040.00
3826904145762NoneVol-II I No 22.15.10 Page No 219Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Door stopper 75mmNo105.0105.032.0FalseNoneNoneFalseNoneFalse3360.00
3826905145762NoneVol-II I No 12.57.2 Page No 105Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 30 mm thick one side teak and one side commercialSqm3667.653667.6546.08FalseNoneNoneFalseNoneFalse169005.3120
17242302450000NoneNoneBuildingsBOREWLL290089.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3826906145763NoneVol-V I No 12.4 Page No 140Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. completeEach5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3826907145763NoneVol-V I No 12.1.1 Page No 139Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrsm388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3826908145763NoneVol-V I No 12.1.2 Page No 139Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Borewell depth of 50 to 100 Mtrsm487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3826909145763NoneVol-V I No 12.1.3 Page No 139Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 100 to 150 Mtrsm517.65517.6520.0FalseNoneNoneFalseNoneFalse10353.00
3826910145763NoneVol-V I No 9.1.2 Page No 95Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 75mm diam257.25257.2560.0FalseNoneNoneFalseNoneFalse15435.00
3826911145763NoneVol-I I No 1.17.1 Page No 10Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 mCum275.1275.127.0FalseNoneNoneFalseNoneFalse7427.70
3826912145763NoneVol-I I No 1.10 Page No 7Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum168.0168.027.0FalseNoneNoneFalseNoneFalse4536.00
3826913145763NoneVol-V I No 13.28 Page No 155Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsm577.5577.5120.0FalseNoneNoneFalseNoneFalse69300.00
3826914145763NoneVol-V I No 13.22.4 Page No 154Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x6 Sqm.m194.25194.25125.0FalseNoneNoneFalseNoneFalse24281.250
3826915145763NoneVol-V I No 13.16.7 Page No 152Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. For 10.00 HP 10.00 HP - 90 LPM @ 220 m = 20 STG Outlet Dia - 2.00"Each57342.657342.61.0FalseNoneNoneFalseNoneFalse57342.60
3826916145763NoneVol-V I No 13.25.1 Page No 154Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mmEach1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3826917145763NoneVol-V I No 12.32 Page No 143Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m2029.652029.6515.0FalseNoneNoneFalseNoneFalse30444.750
3826918145763NoneVol-V I No 11.15.6 Page No 133Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 50 mm dia GM (Copper alloy) Gate valvesEach1772.41772.41.0FalseNoneNoneFalseNoneFalse1772.40
3826919145763NoneVol-V I No 13.24.3 Page No 155Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter for outdoor 6 to 15 HP pumps 2) S-D- Star Delta Starter etc. complete.Each18375.018375.01.0FalseNoneNoneFalseNoneFalse18375.00
3826920145763NoneVol-V I No 12.34 Page No 143Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeEach172.2172.21.0FalseNoneNoneFalseNoneFalse172.20
17242302450000NoneNoneBuildingsELECTRICAL WORK236104.05
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3826921145764NoneCol-VI I No 1.2.1 Page No 2 of 105Supplying heavy gauge PVC conduit pipe .mm dia. mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused way so f junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thickm69.369.3800.0FalseNoneNoneFalseNoneFalse55440.00
3826922145764NoneVol-VI I No 1.2.2 Page No 2 of 105Supplying heavy gauge PVC conduit pipe .mm dia. mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused way so f junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thickm81.981.9675.0FalseNoneNoneFalseNoneFalse55282.50
3826923145764NoneVol-VI I No 1.2.3 Page No 2 of 105Supplying heavy gauge PVC conduit pipe .mm dia. mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused way so f junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 32 mm dia 2.5 mm thickm108.15108.15300.0FalseNoneNoneFalseNoneFalse32445.00
3826924145764NoneVol-VI I No 1.5.1 Page no 2 of 105Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction boxEach51.4551.45200.0FalseNoneNoneFalseNoneFalse10290.00
3826925145764NoneVol-VI I No 1.5.2 Page No 3 of 105Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction boxEach58.858.8150.0FalseNoneNoneFalseNoneFalse8820.00
3826926145764NoneVol-VI I No 1.5.3 Page No 3 of 105Supplying and fixing PVC/metal conduit Deep junction box 32 mm deep Junction boxEach64.0564.0575.0FalseNoneNoneFalseNoneFalse4803.750
3826927145764NoneVol-VI I No 1.13 Page No 4 of 105Supplying And Fixing Metal Fan Box with Round HookNo122.85122.8562.0FalseNoneNoneFalseNoneFalse7616.70
3826928145764NoneVol-VI I No 1.3.1 Page No 2 of 105Supplying heavy gauge PVC Conduit Pipe. dia. mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thickm71.471.4350.0FalseNoneNoneFalseNoneFalse24990.00
3826929145764NoneVol-VI I No 1.3.2 Page No 2 of 105Supplying heavy gauge PVC Conduit Pipe. dia. mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thickm82.9582.95225.0FalseNoneNoneFalseNoneFalse18663.750
3826930145764NoneVol-VI I No 1.3.3 Page No 2 of 105Supplying heavy gauge PVC Conduit Pipe. dia. mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary. 32 mm dia 2.5 mm thickm103.95103.95120.0FalseNoneNoneFalseNoneFalse12474.00
3826931145764NoneVol-VI I No 3.4.2 Page No 8 of 105Supplying and flush mounting powder coated/galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 WayEach166.95166.9519.0FalseNoneNoneFalseNoneFalse3172.050
3826932145764NoneVol-VI I No 3.4.4 Page No 8 of 105Supplying and flush mounting powder coated/galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 WayEach231.0231.02.0FalseNoneNoneFalseNoneFalse462.00
3826933145764NoneVol-VI I No 3.4.5 Page No 8 of 105Supplying and flush mounting powder coated/galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 WayEach274.05274.056.0FalseNoneNoneFalseNoneFalse1644.30
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17242302450000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17242302450000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17242302450000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17242302450000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17242302450000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17242302450000NoneNoneELIGIBILITYAs per Karnataka State Government order No.LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No.PW/134/BMS/2007 Dated 27.7.2007, a sum amounting to 1%of the bill amount will be deducted towards Construction Labour Welfare fund.None
17242302450000NoneNoneELIGIBILITYThe Item Rate quoted shall include the Royalty Charges on construction materials and other taxes as per prevailing Government Orders.None
17242302450000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17242302450000NoneNoneELIGIBILITYThe Tenderer shall obtain the workdone certificate in the prescribed format from the Competent Authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid. The Original Certificate/Certificates shall be produced at the time of opening of technical Bids for physical verificationNone
17242302450000NoneNoneELIGIBILITYFinancial Year will be reckoned as the period between first day of April and Thirty first day of March of succeeding year(both days inclusive).None
17242302450000NoneNoneELIGIBILITYThe Tenderer shall scan the Original Ownership Documents/ Lease/ Hire commitment Agreement for the Machinery and attach the scanned file to the Bid. The Original Documents shall be produced at the time of opening of technical Bids for physical verification.None
17242302450000NoneNoneELIGIBILITYThe Employer reserves the right to Reject any or all Tenders without assigning any reason.None
17242302450000NoneNoneELIGIBILITYThe defect liability period for this work is 365 daysNone
17242302450000NoneNoneELIGIBILITYThe Department is not responsible for any delay in accessing kppp portal.None
17242302450000NoneNoneELIGIBILITYThe rates of all the items appeared in Bill of Quantities are inclusive of all leads and liftsNone
17242302450000NoneNoneELIGIBILITYThe contractor shall bound to comply the prevailing rules and regulations with regard to the EPF rules and any modifications before and after execution of agreementNone
17242302450000NoneNoneELIGIBILITYAfter the award of the contract, the contractor has to furnish the details in respect of labour employed and the EPF details for this work in every RA bill.None
17242302450000NoneNoneELIGIBILITYBidders are advised to note that , 18% GST will be added to the contract amountNone
17242302450000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weight of 10% per year to bring them to the price level of the 2024-25 in the Technical Qualification Criteria mentioned in the next section.None
17242302450000NoneNoneELIGIBILITYThe bidder should mention the UDIN No on the turnover certificate, failing which bid is rejected.None
17242302450000NoneNoneELIGIBILITYIf the bidder uploaded the false document while participating in the tender, the bidder will be responsible and action will be initiated as per the tender clause.None
17242302450000NoneNoneELIGIBILITYThe work should be completed in 11 (Eleven) Months ( including monsoon)None
17242302450001NoneNoneELIGIBILITY5,09,500.00Through e-payment OR The Earnest Money Deposit shall be in two parts. Part (1) Rs. 1,00,000.00 by e-payment, Part (2) Balance EMD of Rs. 4,09,500.00 shall be in favour of Executive Engineer, PWD Dn, sedam and may be in the form of Bankers Cheque / Demand Draft / Pay Order payble at sedam or cash or specified Small Savings Instruments pledged to the Executive Engineer, PWD Dept, Dn, Sedam payble at Sedam or Bank Guarantee in the prescribed format obtained from any Nationalized / Scheduled bank.None
17242302450000NoneNoneELIGIBILITYContractor should upload Difference DD Other wise Tender will Not consideredNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e., 2019-20, 2020-21, 2021-22 ,2022-23 & 2023-24 b) Satisfactorily completed, as prime contractor, at least one similar work such as Building Work of value not less than Rs. 170.00 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e., 2019-20, 2020-21, 2021-22 ,2022-23 & 2023-24 c) Executed in any one year, the following minimum quantities of work: 1) Earth wrok/Emb/Filling 6034.00 Cum 2) PCC/RCC 884.00 Cum 3) TMT Steel 66.00 Tonne 4) Providing and laying of Constructing Solid Concrete Blocks 1464.00 Sqm 5) Providing and laying Polished Granite Stone Flooring 2045.00 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneLiquid Assets and /or availability of credit facilities of no less than Rs. 92.60 lakhs (Credit Lines/letter of credit/ certificates from the banks for meeting the fund requirement etcPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAs per the Govt Order No: FD 263 EXP-12/2022 Bangelore Dated: 11.05.2022 as per condition no 3 relaxation of machinery upto Rs. 300.00 Lakhs i.e. KW-3 & KW-4Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information in Format-8 and scanned copies of the owership Documents & Hire commitment Agreements
NoneNoneNoneNoneQualification and experience of the key technical and Management personnel in permanent employment with the Tenderer and those that are proposed to be deployed on this work, if work is awarded.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Biodata of the personnel
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24a) a) Achieved in at least two financial years an average financial turnover (in all classes of civil engineering construction works only) of Rs.679.00 lakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneReport on the financial standing of the Tenderer, such as profit and loss statements and auditors report for the last five years.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned Copy of ITC Certificate
NoneNoneNoneNoneLatest Income Tax Clearance CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned Copy of ITC Certificate
NoneNoneNoneNoneBanker Details for referenceFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker Details
NoneNoneNoneNoneAssessed Tender Capacity shall be more than the Tendered AmountOthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessement on the Letter Head of the Tenderer
NoneNoneNoneNoneConstitutional or Legal Status of the TendererOthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach copy of registration
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Contractor PWD Registration CertificateTrueTechnical Bid
Annual Turnover Certificate with UDINTrueTechnical Bid
single similar Nature of Work Done Certificate 50percent of APTTrueTechnical Bid
Line of CreditTrueTechnical Bid
LESS DD Upload Difference DD/FDR Nationalized BankTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1724235917000
version0
createdDateNone
modifiedDateNone
blockNumberPWD DIVISION SEDAM
streetNone
citySEDAM
stateKarnataka
pin585222
tenderRecallDTONone