| 1723630506000 | 0 | None | None | Other Works | P3-Construction of toilet room at Govt primary school Aurad and Purchase of LED lights | 236106.27 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3779208 | 142667 | None | code01 | SupplyofLEDStreetlight luminairewithpressurediecastaluminium housing
body for optimal thermal 10322/IEC60598,LM79&
sc
Warrantyof2Years againstanymanufacturing defectworkingunderstandardelectricalconditionsas mentioned above should be given by LEDmanufacturer &Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 90 W (KPTCL SR 2023-24 Vol.06 Electrical items p.no.45) | Each | 6291.6 | 6291.6 | 21.0 | False | None | None | False | None | False | 132123.6 | 0 | | 3779209 | 142667 | None | code02 | Supplying and Fixingof........mm dia classAGI pipe bracket upto2
mslongbent atsuitable angle andfixing tothisbracket street light
fittingofall capacities toGIorGIor rail orRCCpole /wallusing
suitable clamps, bolts, andnuts andwiring using suitablecapacity
wires.Using 25mm dia G.I.Pipe(KPTCL SR 2023-24 Vol.06 Electrical items.13.1.1 p.no.56) | Each | 1026.9 | 1026.9 | 18.0 | False | None | None | False | None | False | 18484.2 | 0 | | 3779210 | 142667 | None | code03 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. PWD DSR 2023-24 Volume-1 IT.NO 1.5 | Cum | 313.95 | 313.95 | 11.25 | False | None | None | False | None | False | 3531.9375 | 0 | | 3779211 | 142667 | None | code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesPWD DSR 2023-24 I.NO 2.1.2 | Cum | 6123.6 | 6123.6 | 0.94 | False | None | None | False | None | False | 5756.184 | 0 | | 3779212 | 142667 | None | code05 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.PWD DSR 2023-24 I.NO 6.7 | Cum | 8376.9 | 8376.9 | 7.08 | False | None | None | False | None | False | 59308.452 | 0 | | 3779213 | 142667 | None | code06 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 13.55 | False | None | None | False | None | False | 3628.0125 | 0 | | 3779214 | 142667 | None | code07 | Providing and fixing brass bib cock of approved quality :PWD SR 2021-22 I.NO 13.2.1 | Each | 320.25 | 320.25 | 2.0 | False | None | None | False | None | False | 640.5 | 0 | | 3779215 | 142667 | None | code08 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/e fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc.PWD DSR 2023-24 I.NO 13.32.2 | Mtr | 397.95 | 397.95 | 12.0 | False | None | None | False | None | False | 4775.4 | 0 | | 3779216 | 142667 | None | code09 | Providing and fixing water closet squatting pan (Indian type W.C. pan )with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: | Each | 5128.2 | 5128.2 | 1.0 | False | None | None | False | None | False | 5128.2 | 0 | | 3779217 | 142667 | None | code10 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations
and cuts of pipes wherever necessary including jointing of PVC pipes
and specials (excluding cost of specials) with jointing of approved
type, with all labour with all lead & lift including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will make
his own arrangements for procuring water for testing).PVC pipes 63mm dia., 6 kg/sqcm & class 3 PWD DSR 2023-24 Vol.5 p.no.113 I.NO 10.1.4 | Mtr | 169.05 | 169.05 | 12.0 | False | None | None | False | None | False | 2028.6 | 0 | | 3779218 | 142667 | None | code11 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. PWD DSR 2023-24 I.NO 12.54 | Mtr | 333.9 | 333.9 | 2.1 | False | None | None | False | None | False | 701.19 | 0 |
|