3833928 | 146193 | None | DMA1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 506.1 | 506.1 | 20.7 | False | None | None | False | None | False | 10476.27 | 0 |
3833929 | 146193 | None | DMA2 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin-charge. | Cum | 1768.2 | 1768.2 | 6.3 | False | None | None | False | None | False | 11139.66 | 0 |
3833930 | 146193 | None | DMA3 | Earth work excavation for foundation of structure upto 3 mtrs. By mechanicle means as per drawing and technical specification, including setting out, providing shoring, strutting and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, filling back the excavated earth to the extent required and utilising / transporting the remaining earth upto 1.00km lead. including cost of labour, materials and HOM of machineries etc., complete Ordinary/Hard Soil. In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 24.0 | False | None | None | False | None | False | 2570.4 | 0 |
3833931 | 146193 | None | DMA4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 3.6 | False | None | None | False | None | False | 22638.42 | 0 |
3833932 | 146193 | None | DMA5 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 sand) | Cum | 6708.45 | 6708.45 | 10.8 | False | None | None | False | None | False | 72451.26 | 0 |
3833933 | 146193 | None | DMA6 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. | Cum | 6639.45 | 6639.45 | 3.44 | False | None | None | False | None | False | 22839.708 | 0 |
3833934 | 146193 | None | DMA7 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire /soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 93929.85 | 93929.85 | 0.275 | False | None | None | False | None | False | 25830.70875 | 0 |
3833935 | 146193 | None | DMA8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8376.9 | 8376.9 | 15.53 | False | None | None | False | None | False | 130093.257 | 0 |
3833936 | 146193 | None | DMA9 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 135.0 | False | None | None | False | None | False | 41816.25 | 0 |
3833937 | 146193 | None | DMA10 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 135.0 | False | None | None | False | None | False | 19419.75 | 0 |
3833938 | 146193 | None | DMA11 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Kg | 118.65 | 118.65 | 1700.0 | False | None | None | False | None | False | 201705.0 | 0 |
3833939 | 146193 | None | DMA12 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications upto 1.5 m. | Sqm | 143.85 | 143.85 | 5.4 | False | None | None | False | None | False | 776.79 | 0 |
3833940 | 146193 | None | DMA13 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 1037.4 | 1037.4 | 1.08 | False | None | None | False | None | False | 1120.392 | 0 |
3833941 | 146193 | None | DMA14 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. | Kg | 599.55 | 599.55 | 5.28 | False | None | None | False | None | False | 3165.624 | 0 |
3833942 | 146193 | None | DMA15 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent | Sqm | 2589.3 | 2589.3 | 121.0 | False | None | None | False | None | False | 313305.3 | 0 |
3833943 | 146193 | None | DMA16 | ISO PROOF SEALER ., . Providing waterproof treatment to rciof slab using 2 coats of acrylic copolymer elastomeric ISOPROOF sealer & protector. The surfaceshall be prepared free of tar. dust. fungus, loose particles etc The surface shall be applied with basecoat of crystallization liquid and then ISOPROOF, wetting agent and liquid (1:1 :6) over the preparedsurface.Inaddition the surface shall be provided with polysulphide/acrylic sealant to V groves, making haunch at junction of parapet and roof slab and at damaged portion using patching mortar to drain off rain water.Overthisonecoatofflexible cementatious membrane (FCM). Spreading 2 layers of 40 gsm non woven geotextile membrane as reinforcing material (over FCM) with one primer coat of ISOPROOF & applying second coat of ISOPROOF liquid over the primer coat - conforming to ASTM D 412 -1992. The work shall be carried out as per the directions of the Engineer in charge. | Sqm | 980.0 | 980.0 | 121.0 | False | None | None | False | None | False | 118580.0 | 0 |
3833944 | 146193 | None | DMA17 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 10" x 7" x 3" (254 x 178 x 76 mm) | Each | 115.36 | 115.36 | 15.0 | False | None | None | False | None | False | 1730.4 | 0 |
3833945 | 146193 | None | DMA18 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. | Mtr | 71.07 | 71.07 | 50.0 | False | None | None | False | None | False | 3553.5 | 0 |
3833946 | 146193 | None | DMA19 | Point wiring using Copper wire with switch.
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row,above 6Mts upto 10Mtr from tapping point to out let via switches | Point | 1066.05 | 1066.05 | 30.0 | False | None | None | False | None | False | 31981.5 | 0 |
3833947 | 146193 | None | DMA20 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100Vgrade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 | Mtr | 26.78 | 26.78 | 100.0 | False | None | None | False | None | False | 2678.0 | 0 |
3833948 | 146193 | None | DMA21 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100Vgrade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 | Mtr | 43.26 | 43.26 | 100.0 | False | None | None | False | None | False | 4326.0 | 0 |
3833949 | 146193 | None | DMA22 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way | Each | 178.19 | 178.19 | 15.0 | False | None | None | False | None | False | 2672.85 | 0 |
3833950 | 146193 | None | DMA23 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/PVC box. 6 Module | Each | 241.02 | 241.02 | 15.0 | False | None | None | False | None | False | 3615.3 | 0 |
3833951 | 146193 | None | DMA24 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 105.06 | 105.06 | 70.0 | False | None | None | False | None | False | 7354.2 | 0 |
3833952 | 146193 | None | DMA25 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket | Each | 176.13 | 176.13 | 10.0 | False | None | None | False | None | False | 1761.3 | 0 |
3833953 | 146193 | None | DMA26 | Supplying & fixing of Porcelain fuse channel with cutout on existing wooden/panel using necessary nuts, bolts and washers. | Each | 711.73 | 711.73 | 2.0 | False | None | None | False | None | False | 1423.46 | 0 |
3833954 | 146193 | None | DMA27 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC61439-3 and IK09 tested as per IS/IEC62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/woodboard/flush mounting using required clA, bolts ,nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3phase Double door with necessary busbar completely wired to use on 440V 3phase 4wire powder coated painting etc.,complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 Way | Each | 15994.87 | 15994.87 | 1.0 | False | None | None | False | None | False | 15994.87 | 0 |
3833955 | 146193 | None | DMA28 | Supplying of feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours 70 lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Each | 567.53 | 567.53 | 10.0 | False | None | None | False | None | False | 5675.3 | 0 |
3833956 | 146193 | None | DMA29 | Supplying & fixing retrofit type-PL-LED Lamp......W LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80lumen per W ,life 25000 burning hours and Compliance to IS10322/IEC60598, LM79 & LM80.The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM79. The operating input voltage should be between 130 to 275V. Tested by NABL/CPRI accredited laboratory with 2years Warranty against any manufacturing defect working under standard electrical condition 18+B141-18-20W | Each | 723.06 | 723.06 | 15.0 | False | None | None | False | None | False | 10845.9 | 0 |
3833957 | 146193 | None | DMA30 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230V,50cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model | Each | 3073.52 | 3073.52 | 10.0 | False | None | None | False | None | False | 30735.2 | 0 |