| 3713145 | 137213 | None | code001 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR) | Cum | 107.1 | 107.1 | 253.9 | False | None | None | False | None | False | 27192.69 | 0 |
| 3713146 | 137213 | None | code002 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR) | Cum | 5947.2 | 5947.2 | 200.33 | False | None | None | False | None | False | 1191402.576 | 0 |
| 3713147 | 137213 | None | code003 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) Pit Base Slab | Cum | 7322.4 | 7322.4 | 63.55 | False | None | None | False | None | False | 465338.52 | 0 |
| 3713148 | 137213 | None | code004 | Pit side wall | Cum | 11340.0 | 11340.0 | 31.72 | False | None | None | False | None | False | 359704.8 | 0 |
| 3713149 | 137213 | None | code005 | Hall Grade slab | Cum | 7322.4 | 7322.4 | 244.34 | False | None | None | False | None | False | 1789155.216 | 0 |
| 3713150 | 137213 | None | code006 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115) | Cum | 9820.8 | 9820.8 | 20.13 | False | None | None | False | None | False | 197692.704 | 0 |
| 3713151 | 137213 | None | code007 | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR) | Kg | 93929.85 | 93929.85 | 21.76 | False | None | None | False | None | False | 2043913.536 | 0 |
| 3713152 | 137213 | None | code008 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR) | Cum | 6708.45 | 6708.45 | 91.28 | False | None | None | False | None | False | 612347.316 | 0 |
| 3713153 | 137213 | None | code009 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR) | Cum | 474.0 | 474.0 | 1561.16 | False | None | None | False | None | False | 739989.84 | 0 |
| 3713154 | 137213 | None | code010 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR) | Sqm | 1292.55 | 1292.55 | 428.76 | False | None | None | False | None | False | 554193.738 | 0 |
| 3713155 | 137213 | None | code011 | Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2) | Sqm | 309.75 | 309.75 | 892.27 | False | None | None | False | None | False | 276380.6325 | 0 |
| 3713156 | 137213 | None | code012 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2) | Kgs | 118.65 | 118.65 | 78600.0 | False | None | None | False | None | False | 9325890.0 | 0 |
| 3713157 | 137213 | None | code013 | 7.69 Providing and fixing Aluminium Turbo ventilator complete as per technical
specifications 7.69.1 Non Power Driven with 0.9mm thickness and 38 No.s of Vanes & turbine doom thickness 1mm and total weight not less than 5.2kg for Industrial se. No 5,220.00.(Item No. 8.51, Page No. 50, Vol.2) | Each | 5481.0 | 5481.0 | 12.0 | False | None | None | False | None | False | 65772.0 | 0 |
| 3713158 | 137213 | None | code014 | 394 Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm m2 280.00.(Item No. 394, Page No. A-24, Vol.2) | Each | 294.0 | 294.0 | 1050.0 | False | None | None | False | None | False | 308700.0 | 0 |
| 3713159 | 137213 | None | code015 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2) | Sqm | 585.04 | 585.04 | 3159.55 | False | None | None | False | None | False | 1848463.132 | 0 |
| 3713160 | 137213 | None | code016 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2) | Sqm | 105.0 | 105.0 | 892.27 | False | None | None | False | None | False | 93688.35 | 0 |
| 3713161 | 137213 | None | code017 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2) | No | 76.65 | 76.65 | 432.91 | False | None | None | False | None | False | 33182.5515 | 0 |
| 3713162 | 137213 | None | code018 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2) | No | 76.65 | 76.65 | 395.87 | False | None | None | False | None | False | 30343.4355 | 0 |
| 3713163 | 137213 | None | code019 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2) | Sqm | 2764.65 | 2764.65 | 57.38 | False | None | None | False | None | False | 158635.617 | 0 |
| 3713164 | 137213 | None | code020 | Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2) | No | 25920.3 | 25920.3 | 3.0 | False | None | None | False | None | False | 77760.9 | 0 |
| 3713165 | 137213 | None | code021 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2) | Kg | 474.6 | 474.6 | 690.0 | False | None | None | False | None | False | 327474.0 | 0 |
| 3713166 | 137213 | None | code022 | MainPanel SupplyingandfixingMouldedCaseCircuitBreaker(MCCB)overtheexistingwoodpanelboardusingnecessaryscrews,bolts,nuts,necessaryphaseseparators,handleandwiringcomplete.ProtectionofOverloadandShortcircuitwithadjustablethermalmagneticrelease,MicroprocessorreleaseshallhaveEarthFaultasperIIEC609472.Icu10lcsIn4PMCCB,allPolesshouldhaveprotectionforShortCicrcuitOverLoad.ForMicroprocessorMCCBSFacilityforsegregatingPriorityandNonPriorityloadsmustbeavailableintheMCCB.MCCBshallbeprovidedwithdoubleinsulation(insulationbetweenfrontcoverandinternalpowercircuitstoavoidanyaccidentalcontactwithlivecurrentcarryingpathwiththefrontcoveropen).Multi-polebreakersshallbedesignedtobreakallthepolessimultaneously and they shall have a single mechanism. Incomer : MCCB TPN 200A with CBCT ELR & Ph indicators, meter section with all parameters as required Outgoings: 100A TP MCCB feeder- 01No 5.15.9 100 A 25 Ka Each 8487.00 (PWD Sr Vol-6 I.no : 5.15.9 Pno: 18) | No | 8487.0 | 8487.0 | 6.0 | False | None | None | False | None | False | 50922.0 | 0 |
| 3713167 | 137213 | None | code023 | 5.19upplyingandfixingregularMCBdistributionboardsonwall/oodboard/flushmountingusingrequiredclamps,bolts,nutsetc.,withprovisionforfixingsuitabletypecapacityMCB'ssinglephase/3phase/singledoorwithpowdercoatedpaintingMadeoutof14SWGMS enclosure 5.19.15 16 Way SP & N Each 10395.00(PWD Sr Vol-6 I.no : 5.19.15 Pno:18) | No | 10395.0 | 10395.0 | 7.0 | False | None | None | False | None | False | 72765.0 | 0 |
| 3713168 | 137213 | None | code024 | 190 30.01 8 Way with Poreclain Rewireable Cutout and & 1 No of 630 Amps Load Break Switch with Copper Busbar as per IS-13947 Part-1&2(Refer Dwg No. BESCOM/GM/QS&S/41 Dtd 24.11.2018) 300308 No 52119 (PWD Sr Vol-6 I.no : 30.01 Pno: 12/81) | No | 52119.0 | 52119.0 | 1.0 | False | None | None | False | None | False | 52119.0 | 0 |
| 3713169 | 137213 | None | code025 | Sub panel-1 Incomer : MCB TPN 63A with CBCT ELR & Ph indicators, section with all parameters as required | No | 40000.0 | 40000.0 | 2.0 | False | None | None | False | None | False | 80000.0 | 0 |
| 3713170 | 137213 | None | code026 | 599 69.04 Aluminium Busbar/Wire Pieces 791010
Kg 161.68 136 63A 4 Wire 16kA 415V Aluminium busbars compartment. (PWD Sr Vol-6 I.no : 30.01 Pno: 12/81) | No | 136.0 | 136.0 | 2.0 | False | None | None | False | None | False | 272.0 | 0 |
| 3713171 | 137213 | None | code027 | 5.46 Supplying andfixing of Modular MCBD evices (Tripper)WithBrak ng capacity of 6kA.5.46.663 A TP Each 1195.00 Pno : 21 Outgoings: 40/63A 4P MCB feeder- 10Nos.. | No | 1195.0 | 1195.0 | 10.0 | False | None | None | False | None | False | 11950.0 | 0 |
| 3713172 | 137213 | None | code028 | 5.17 Supplying andfixing regular MCCB distribution Panel confirming to IS/IEC61439 3 and IK09 tested as pe rIS/IEC62262withminimumIP43protectionprovidedwithPolyurethane(PUR)gasket,withsuitableearthingsystem,onwall/woodboard/flushmountingusingrequiredclA,bolts,nuts,etc.,withprovisionforfixingofsuitabletypecapacityMCCB'sasanincomerfor3phaseDoubledoorwithnecessarybusbarcompletelywiredtouseon440V3phase4wirepowdercoatedpaintingetc.,completewithaprovisionforfixingofsingle/threephasesuitablecapacityMCB'sasoutgoingsconfirmingtoIS/IEC 60898 - 2.5.17.1 4 Way Each
10329.00 pno : 17 | No | 10329.0 | 10329.0 | 2.0 | False | None | None | False | None | False | 20658.0 | 0 |
| 3713173 | 137213 | None | code029 | 3.13 Supplying and fixing of metal clad industrial plugs and sockets. 3.13.8 32A Each 827.82 Pno : 09 Outgoings: 32A Industrial socket-04Nos. | No | 827.82 | 827.82 | 4.0 | False | None | None | False | None | False | 3311.28 | 0 |
| 3713174 | 137213 | None | code030 | Outgoings: 16A Industrial socket-04Nos.3.13.7 16A Each
633.78 Pno : 09 | No | 633.78 | 633.78 | 4.0 | False | None | None | False | None | False | 2535.12 | 0 |
| 3713175 | 137213 | None | code031 | LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 212 32.16 150 Sqmm, 3.5 Core, (25 GI Strips - 4 x 0.8 mm) 287213 KM 554655 | Mtr | 554.65 | 554.65 | 200.0 | False | None | None | False | None | False | 110930.0 | 0 |
| 3713176 | 137213 | None | code032 | 209 32.13 70 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm) 287210 KM 317912 (PWD SR Vol-6 ELE I.No : 32.13 P.No: 13) | Mtr | 317.91 | 317.91 | 200.0 | False | None | None | False | None | False | 63582.0 | 0 |
| 3713177 | 137213 | None | code033 | 207 32.11 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) 287208 KM 178973 (PWD SR Vol-6 ELE I.No : 32.11 P.No: 13) | Mtr | 178.97 | 178.97 | 100.0 | False | None | None | False | None | False | 17897.0 | 0 |
| 3713178 | 137213 | None | code034 | 204 32.08 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm) 287207 KM 179844 (PWD SR Vol-6 ELE I.No : 32.08 P.No: 13) | Mtr | 179.84 | 179.84 | 100.0 | False | None | None | False | None | False | 17984.0 | 0 |
| 3713179 | 137213 | None | code035 | 20132.05 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) 287206 KM 141842 (PWD SR Vol-6 ELE I.No : 32.13 P.No: 13) | Mtr | 141.84 | 141.84 | 160.0 | False | None | None | False | None | False | 22694.4 | 0 |
| 3713180 | 137213 | None | code036 | 32 199 32.03 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) 287205 KM 118004 (PWD SR Vol-6 ELE I.No : 32.03 P.No: 13) | Mtr | 118.0 | 118.0 | 180.0 | False | None | None | False | None | False | 21240.0 | 0 |
| 3713181 | 137213 | None | code037 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable 251 35.03 3.5 x 150/185 Sqmm (PWD SR Vol-6 ELE I.No : 34.10 P.No: 14) 480 3.5Cx150 Sqmm Al Ar cable | Set | 480.0 | 480.0 | 8.0 | False | None | None | False | None | False | 3840.0 | 0 |
| 3713182 | 137213 | None | code038 | 250 35.02 3.5 x 70/95/120 Sqmm Set 382
(PWD SR Vol-6 ELE I.No : 34.08 P.No: 14) 3Cx70 Sqmm Al Ar cable | Set | 382.0 | 382.0 | 8.0 | False | None | None | False | None | False | 3056.0 | 0 |
| 3713183 | 137213 | None | code039 | 250 35.02 3.5 x 70/95/120 Sqmm 288159 Set 382
(PWD SR Vol-6 ELE I.No : 34.08 P.No: 14) 3.5Cx50 Sqmm Al Ar cable | Set | 382.0 | 382.0 | 8.0 | False | None | None | False | None | False | 3056.0 | 0 |
| 3713184 | 137213 | None | code040 | 249 35.01 Up to 4C x 50 Sqmm Set 324
(PWD SR Vol-6 ELE I.No : 34.06 P.No: 14) 4Cx25 Sqmm Al Ar cable | Set | 324.0 | 324.0 | 10.0 | False | None | None | False | None | False | 3240.0 | 0 |
| 3713185 | 137213 | None | code041 | 249 35.01 Up to 4C x 50 Sqmm Set 324
(PWD SR Vol-6 ELE I.No : 34.06 P.No: 14) 4Cx16 Sqmm Al Ar cable | Set | 324.0 | 324.0 | 12.0 | False | None | None | False | None | False | 3888.0 | 0 |
| 3713186 | 137213 | None | code042 | 249 35.01 Up to 4C x 50 Sqmm Set 324
(PWD SR Vol-6 ELE I.No : 34.06 P.No: 14) 4Cx10 Sqmm Cu Ar cable | Set | 324.0 | 324.0 | 14.0 | False | None | None | False | None | False | 4536.0 | 0 |
| 3713187 | 137213 | None | code043 | 249 35.01 Up to 4C x 50 Sqmm Set 324
(PWD SR Vol-6 ELE I.No : 34.06 P.No: 14) 4Cx6.0 Sqmm Cu Ar cable | Set | 324.0 | 324.0 | 14.0 | False | None | None | False | None | False | 4536.0 | 0 |
| 3713188 | 137213 | None | code044 | 249 35.01 Up to 4C x 50 Sqmm Set 324
(PWD SR Vol-6 ELE I.No : 34.06 P.No: 14) 3Cx6.0 Sqmm Cu Un Ar cable | Set | 324.0 | 324.0 | 16.0 | False | None | None | False | None | False | 5184.0 | 0 |
| 3713189 | 137213 | None | code045 | 249 35.01 Up to 4C x 50 Sqmm Set 324
(PWD SR Vol-6 ELE I.No : 34.06 P.No: 14) 3Cx4.0 Sqmm Cu Un Ar cable | Set | 324.0 | 324.0 | 12.0 | False | None | None | False | None | False | 3888.0 | 0 |
| 3713190 | 137213 | None | code046 | Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 4.17 50 to 95 Sqmm 1261 (PWD SR Vol-6 ELE I.No : 34.01 P.No: 14) 70 Sqmm Al Ar cable (tinned copper lug) | Set | 1261.0 | 1261.0 | 8.0 | False | None | None | False | None | False | 10088.0 | 0 |
| 3713191 | 137213 | None | code047 | 34.16 25 to 35 Sqmm (PWD SR Vol-6 ELE I.No : 34.01 P.No: 14) 820 25 Sqmm Al Ar cable (tinned copper lug) | Set | 820.0 | 820.0 | 8.0 | False | None | None | False | None | False | 6560.0 | 0 |
| 3713192 | 137213 | None | code048 | 34.15 10 to 16 Sqmm Set 630 (PWD SR Vol-6 ELE I.No : 34.01 P.No: 14) 16 Sqmm Al Ar cable (tinned copper lug) | Set | 630.0 | 630.0 | 8.0 | False | None | None | False | None | False | 5040.0 | 0 |
| 3713193 | 137213 | None | code049 | 34.15 10 to 16 Sqmm Set 630 (PWD SR Vol-6 ELE I.No : 34.01 P.No: 14) 10 Sqmm Cu Ar cable (tinned copper lug) | Set | 630.0 | 630.0 | 8.0 | False | None | None | False | None | False | 5040.0 | 0 |
| 3713194 | 137213 | None | code050 | 34.01 10 Sqmm, 2 Core (PWD SR Vol-6 ELE I.No : 34.01 P.No: 14) 6.0 Sqmm Cu Ar cable (tinned copper lug) | Set | 630.0 | 630.0 | 8.0 | False | None | None | False | None | False | 5040.0 | 0 |
| 3713195 | 137213 | None | code051 | 34.01 10 Sqmm, 2 Core (PWD SR Vol-6 ELE I.No : 34.01 P.No: 14) 6.0 Sqmm Cu Un Ar cable (tinned copper lug) | Set | 630.0 | 630.0 | 8.0 | False | None | None | False | None | False | 5040.0 | 0 |
| 3713196 | 137213 | None | code052 | 34.01 10 Sqmm, 2 Core (PWD SR Vol-6 ELE I.No : 34.01 P.No: 14) 4.0 Sqmm Cu Un Ar cable (tinned copper lug) | Set | 630.0 | 630.0 | 8.0 | False | None | None | False | None | False | 5040.0 | 0 |
| 3713197 | 137213 | None | code053 | PVC conduits & Accessories Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 19/20mm dia PVC 2mm thick conduit | Mtr | 69.0 | 69.0 | 735.0 | False | None | None | False | None | False | 50715.0 | 0 |
| 3713198 | 137213 | None | code054 | CSR Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-1 25mm dia PVC 2mm thick conduit | Mtr | 81.0 | 81.0 | 600.0 | False | None | None | False | None | False | 48600.0 | 0 |
| 3713199 | 137213 | None | code055 | CSR Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-1 32mm dia PVC 2mm thick conduit | Mtr | 106.0 | 106.0 | 400.0 | False | None | None | False | None | False | 42400.0 | 0 |
| 3713200 | 137213 | None | code056 | CSR Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-1 40mm dia PVC 2mm thick conduit | Mtr | 149.0 | 149.0 | 500.0 | False | None | None | False | None | False | 74500.0 | 0 |
| 3713201 | 137213 | None | code057 | Point wiring using Copper wire with switch SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet. 1 Light point upto 3Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-1, PAGE NO-5 | Nos | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 |
| 3713202 | 137213 | None | code058 | 1 Light point above 3M upto 6Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-1, PAGE NO-5 | Nos | 394.0 | 394.0 | 5.0 | False | None | None | False | None | False | 1970.0 | 0 |
| 3713203 | 137213 | None | code059 | 1 Light point above 6M upto 10Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-1, PAGE NO-5 | Nos | 570.0 | 570.0 | 17.0 | False | None | None | False | None | False | 9690.0 | 0 |
| 3713204 | 137213 | None | code060 | 2 Light point above 3Mtr upto 6Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5 | Nos | 708.0 | 708.0 | 2.0 | False | None | None | False | None | False | 1416.0 | 0 |
| 3713205 | 137213 | None | code061 | 2 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5 | Nos | 708.0 | 708.0 | 2.0 | False | None | None | False | None | False | 1416.0 | 0 |
| 3713206 | 137213 | None | code062 | 3 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-1, PAGE NO-5 | Nos | 1035.0 | 1035.0 | 8.0 | False | None | None | False | None | False | 8280.0 | 0 |
| 3713207 | 137213 | None | code063 | Circuit main wiring Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.0 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-1, PAGE NO-5 | Mtr | 19.0 | 19.0 | 1100.0 | False | None | None | False | None | False | 20900.0 | 0 |
| 3713208 | 137213 | None | code064 | 1.5 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-1, PAGE NO-5 | Mtr | 26.0 | 26.0 | 1100.0 | False | None | None | False | None | False | 28600.0 | 0 |
| 3713209 | 137213 | None | code065 | 2.5 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-1, PAGE NO-5 | Mtr | 42.0 | 42.0 | 800.0 | False | None | None | False | None | False | 33600.0 | 0 |
| 3713210 | 137213 | None | code066 | 4.0 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-1, PAGE NO-5 | Mtr | 63.0 | 63.0 | 630.0 | False | None | None | False | None | False | 39690.0 | 0 |
| 3713211 | 137213 | None | code067 | 6.0 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-1, PAGE NO-5 | Mtr | 92.0 | 92.0 | 450.0 | False | None | None | False | None | False | 41400.0 | 0 |
| 3713212 | 137213 | None | code068 | 10 -12 Way Polycarbonate switch box plate CSR Electrical SR-2023-24, ITEM NO:3.5.7 ,CH-3, PAGE NO-8 | Nos | 344.0 | 344.0 | 1.0 | False | None | None | False | None | False | 344.0 | 0 |
| 3713213 | 137213 | None | code069 | 18 Way Polycarbonate switch box plate CSR Electrical SR-2023-24, ITEM NO:3.5.8 ,CH-3, PAGE NO-8 | Nos | 457.0 | 457.0 | 1.0 | False | None | None | False | None | False | 457.0 | 0 |
| 3713214 | 137213 | None | code070 | Switches & sockets outlets in Existing modular box 6A one way switch CSR Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-9 | Nos | 102.0 | 102.0 | 25.0 | False | None | None | False | None | False | 2550.0 | 0 |
| 3713215 | 137213 | None | code071 | 6A Two way switch CSR Electrical SR-2023-24, ITEM NO:3.6.2 ,CH-3, PAGE NO-9 | Nos | 166.0 | 166.0 | 11.0 | False | None | None | False | None | False | 1826.0 | 0 |
| 3713216 | 137213 | None | code072 | 6A 5Pin socket CSR Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-9 | Nos | 171.0 | 171.0 | 30.0 | False | None | None | False | None | False | 5130.0 | 0 |
| 3713217 | 137213 | None | code073 | Stepped fan regulator CSR Electrical SR-2023-24, ITEM NO:3.6.4 ,CH-3, PAGE NO-9 | Nos | 357.0 | 357.0 | 20.0 | False | None | None | False | None | False | 7140.0 | 0 |
| 3713218 | 137213 | None | code074 | 6/16A Universal socket CSR Electrical SR-2023-24, ITEM NO:3.6.10 ,CH-3, PAGE NO-9 | Nos | 236.0 | 236.0 | 20.0 | False | None | None | False | None | False | 4720.0 | 0 |
| 3713219 | 137213 | None | code075 | Light fixture Supply & fixing of 100W LED light fixture IP 65, included screws accessoris Etc..Considered outdoor type light fitting for equivalent. CSR Electrical SR-2023-24, ITEM NO:11.9.2, PAGE NO-37 | Nos | 9486.0 | 9486.0 | 25.0 | False | None | None | False | None | False | 237150.0 | 0 |
| 3713220 | 137213 | None | code076 | Earthing 12.58 GI/Copper strips for grounding connections, using necessary fixing materials as required.(PWD SR Vol-6 ELE I.No : 5.21 P.No: 18) 12.58.3 25 x 6 mm GI strip m 128.00 | Mtr | 128.0 | 128.0 | 500.0 | False | None | None | False | None | False | 64000.0 | 0 |
| 3713221 | 137213 | None | code077 | 61 8.02 8 SWG GI Wire(4.064 mm Dia), Std Wt: 131 Kg/KM MT
75040 (PWD SR Vol-6 ELE I.No : 8.02 P.No: 5) 8.0 SWG GI bare wire | Mtr | 75045.0 | 75045.0 | 0.0312 | False | None | None | False | None | False | 2341.404 | 0 |
| 3713222 | 137213 | None | code078 | 22 Control Cables and UG Cables ii Cable tray of 300 mm width (suitable for cable duct of D type) Supplying & Laying cable trays including welding, fixing of supports461 + 293
(PWD SR Vol-6 ELE I.No : 22 a ii P.No: 120) Supply & installation of Cable Trays fixed with MS angles, hitech & anchor fastner supports at interval 0.9M interval shall be included complete run below ceiling/wall. Supply & installation of GI Ladder type cable tray 300x50mm Market Price | Mtr | 754.0 | 754.0 | 140.0 | False | None | None | False | None | False | 105560.0 | 0 |
| 3713223 | 137213 | None | code079 | Pipe earthing 5.21 Supplying,fixingandwiringearthleakagerelaywithcorebalancedcurrent transformers uitable fo rsingle phase 50Hz ACwithlatestmicrocontrollerbased,digitalreadoutofpercentageleakagecurrent,programmabledelay/auto/manualresetfacilitysuitabletomountonDIN rail/ flush mounting on panel board. Each 9255.00(PWD SR Vol-6 ELE I.No : 5.21 P.No: 18) Supply & installation of GI PIPE Earthing as per IS:3043 with all installation details | Nos | 9255.0 | 9255.0 | 4.0 | False | None | None | False | None | False | 37020.0 | 0 |