| 1724151366000 | 1 | None | None | Buildings | Construction of SWM Site Belongs ( Window Platform and Office Building) in Kanakagiri TP Limit | 8202997.99 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3820694 | 145358 | None | I No 1.15.2 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blastingmaterials, tools, usage of Machinery & all other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m | Cum | 446.25 | 446.25 | 207.3 | False | None | None | False | None | False | 92507.625 | 0 | | 3820695 | 145358 | None | I No 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 | Cum | 6708.45 | 6708.45 | 100.54 | False | None | None | False | None | False | 674467.563 | 0 | | 3820696 | 145358 | None | I No 1.11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 454.65 | 454.65 | 105.12 | False | None | None | False | None | False | 47792.808 | 0 | | 3820697 | 145358 | None | I No 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 19.52 | False | None | None | False | None | False | 127423.632 | 0 | | 3820698 | 145358 | None | I No 2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates. | Cum | 6652.8 | 6652.8 | 23.87 | False | None | None | False | None | False | 158802.336 | 0 | | 3820699 | 145358 | None | I No 1 | Providing and removing centering, shutting, strutting, propping etc., for Foundation cost of all materials, labour complete as per specifications. Specification | Cum | 532.22 | 532.22 | 10.8 | False | None | None | False | None | False | 5747.976 | 0 | | 3820700 | 145358 | None | I No 8 | Providing and removing centering, shutting, strutting, propping etc., for Column cost of all materials, labour complete as per specifications. Specification | Cum | 4656.96 | 4656.96 | 3.38 | False | None | None | False | None | False | 15740.5248 | 0 | | 3820701 | 145358 | None | I No 9 | Providing and removing centering, shutting, strutting, propping etc., for Plinth beams cost of all materials, labour complete as per specifications. Specification | Cum | 3326.4 | 3326.4 | 9.69 | False | None | None | False | None | False | 32232.816 | 0 | | 3820702 | 145358 | None | I No 2.5.2 | Providing and laying in position Reinforced cement concrete (Columns) for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 18.33 | False | None | None | False | None | False | 131703.7995 | 0 | | 3820703 | 145358 | None | I No 1a | Providing and removing centering, shutting, strutting, propping etc., for Columns cost of all materials, labour complete as per specifications. Specification | Cum | 5029.61 | 5029.61 | 8.64 | False | None | None | False | None | False | 43455.8304 | 0 | | 3820704 | 145358 | None | I No 12 | Providing and removing centering, shutting, strutting, propping etc., for Beams cost of all materials, labour complete as per specifications. Specification | Cum | 4311.09 | 4311.09 | 9.69 | False | None | None | False | None | False | 41774.4621 | 0 | | 3820705 | 145358 | None | I No 11.2 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 118.65 | 118.65 | 6000.0 | False | None | None | False | None | False | 711900.0 | 0 | | 3820706 | 145358 | None | I No 7.1.1 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in | Sqm | 922.95 | 922.95 | 420.0 | False | None | None | False | None | False | 387639.0 | 0 | | 3820707 | 145358 | None | I No 7.4.1 | Providing & fixing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete as per design drawings. | m | 670.95 | 670.95 | 28.0 | False | None | None | False | None | False | 18786.6 | 0 | | 3820708 | 145358 | None | I No 8.33.3 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifica tions and as per directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 9.1 | False | None | None | False | None | False | 1328.145 | 0 | | 3820709 | 145358 | None | I No 4.2ii | Construction of granular sub-base byproviding close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface andcompacting with vibratory power roller to achieve the desired density, complete as per clause | Cum | 2553.6 | 2553.6 | 303.45 | False | None | None | False | None | False | 774889.92 | 0 | | 3820710 | 145358 | None | I No 4.17 | Wet Mix Macadam (Plant mix method) - Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with Grader in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density | Cum | 2686.95 | 2686.95 | 182.07 | False | None | None | False | None | False | 489212.9865 | 0 | | 3820711 | 145358 | None | I No 16.28 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 m3 capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work | Cum | 7091.7 | 7091.7 | 182.07 | False | None | None | False | None | False | 1291185.819 | 0 | | 3820712 | 145358 | None | I No 2.4.2 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately | Cum | 6639.15 | 6639.15 | 6.2 | False | None | None | False | None | False | 41162.73 | 0 | | 3820713 | 145358 | None | I No 1 | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specifications | Cum | 14406.96 | 14406.96 | 1.0 | False | None | None | False | None | False | 14406.96 | 0 | | 3820714 | 145358 | None | I No 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings | t | 93929.85 | 93929.85 | 12.27 | False | None | None | False | None | False | 1152519.2595 | 0 | | 3820715 | 145358 | None | I No 11.6.2 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 2628.15 | 2628.15 | 30.2 | False | None | None | False | None | False | 79370.13 | 0 | | 3820716 | 145358 | None | I No 1.2.2 | Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick | m | 84.0 | 84.0 | 40.0 | False | None | None | False | None | False | 3360.0 | 0 | | 3820717 | 145358 | None | I No 1.5.2 | PVC/metal conduit Deep junction box. Supplying and fixing PVC/metal conduit Deep junction box | No | 53.55 | 53.55 | 4.0 | False | None | None | False | None | False | 214.2 | 0 | | 3820718 | 145358 | None | I No 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall | No | 341.25 | 341.25 | 4.0 | False | None | None | False | None | False | 1365.0 | 0 | | 3820719 | 145358 | None | I No 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box | No | 381.15 | 381.15 | 4.0 | False | None | None | False | None | False | 1524.6 | 0 | | 3820720 | 145358 | None | I No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 Sqmm | m | 42.0 | 42.0 | 50.0 | False | None | None | False | None | False | 2100.0 | 0 | | 3820721 | 145358 | None | I No 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps one way | No | 92.4 | 92.4 | 3.0 | False | None | None | False | None | False | 277.2 | 0 | | 3820722 | 145358 | None | I No 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps two way | No | 159.6 | 159.6 | 3.0 | False | None | None | False | None | False | 478.8 | 0 | | 3820723 | 145358 | None | I No 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket | No | 170.1 | 170.1 | 3.0 | False | None | None | False | None | False | 510.3 | 0 | | 3820724 | 145358 | None | I No 3.15.4 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854 and IS 1293. 6A Bakelite Ceiling Rose 6A Lamp Holder | No | 66.15 | 66.15 | 4.0 | False | None | None | False | None | False | 264.6 | 0 | | 3820725 | 145358 | None | I No 11.3.2 | Supplying of .....feet PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting | No | 777.0 | 777.0 | 4.0 | False | None | None | False | None | False | 3108.0 | 0 | | 3820726 | 145358 | None | I No 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition | No | 876.75 | 876.75 | 4.0 | False | None | None | False | None | False | 3507.0 | 0 | | 3820727 | 145358 | None | I No 5.17.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps SP | No | 549.15 | 549.15 | 4.0 | False | None | None | False | None | False | 2196.6 | 0 | | 3820728 | 145358 | None | I No 5.17.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps DP | No | 1158.15 | 1158.15 | 4.0 | False | None | None | False | None | False | 4632.6 | 0 | | 3820729 | 145358 | None | I No 32.14 | Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm) | Km | 539742.0 | 539742.0 | 0.07 | False | None | None | False | None | False | 37781.94 | 0 | | 3820730 | 145358 | None | I No M 1 | GESCOM DEPOSIT | No | 10000.0 | 10000.0 | 1.0 | False | None | None | False | None | False | 10000.0 | 0 | | 3820731 | 145358 | None | I No 1.15.2 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blastingmaterials, tools, usage of Machinery & all other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m | Cum | 446.25 | 446.25 | 67.69 | False | None | None | False | None | False | 30206.6625 | 0 | | 3820732 | 145358 | None | I No 1.11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 454.65 | 454.65 | 50.56 | False | None | None | False | None | False | 22987.104 | 0 | | 3820733 | 145358 | None | I No 2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 3.37 | False | None | None | False | None | False | 20042.064 | 0 | | 3820734 | 145358 | None | I No 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 5.16 | False | None | None | False | None | False | 33683.706 | 0 | | 3820735 | 145358 | None | I No 2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates. | Cum | 6652.8 | 6652.8 | 12.22 | False | None | None | False | None | False | 81297.216 | 0 | | 3820736 | 145358 | None | I No 1 | Providing and removing centering, shutting, strutting, propping etc., for Foundation cost of all materials, labour complete as per specifications. Specification | Cum | 532.22 | 532.22 | 6.48 | False | None | None | False | None | False | 3448.7856 | 0 | | 3820737 | 145358 | None | I No 8 | Providing and removing centering, shutting, strutting, propping etc., for Column cost of all materials, labour complete as per specifications. Specification | Cum | 4656.96 | 4656.96 | 1.86 | False | None | None | False | None | False | 8661.9456 | 0 | | 3820738 | 145358 | None | I No 1a | Providing and removing centering, shutting, strutting, propping etc., for Plinth beams cost of all materials, labour complete as per specifications. Specification | Cum | 3326.4 | 3326.4 | 3.88 | False | None | None | False | None | False | 12906.432 | 0 | | 3820739 | 145358 | None | I No 2.5.2 | Providing and laying in position Reinforced cement concrete (Columns) for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse | Cum | 7185.15 | 7185.15 | 16.65 | False | None | None | False | None | False | 119632.7475 | 0 | | 3820740 | 145358 | None | I No 1a | Providing and removing centering, shutting, strutting, propping etc., for Columns cost of all materials, labour complete as per specifications. Specification | Cum | 5029.61 | 5029.61 | 3.35 | False | None | None | False | None | False | 16849.1935 | 0 | | 3820741 | 145358 | None | I No 12 | Providing and removing centering, shutting, strutting, propping etc., for Beams cost of all materials, labour complete as per specifications. Specification | Cum | 4311.09 | 4311.09 | 3.63 | False | None | None | False | None | False | 15649.2567 | 0 | | 3820742 | 145358 | None | I No 13 | Providing and removing centering, shutting, strutting, propping etc., for Slabs cost of all materials, labour complete as per specifications. Specification | Cum | 4311.09 | 4311.09 | 7.06 | False | None | None | False | None | False | 30436.2954 | 0 | | 3820743 | 145358 | None | I No 12 | Providing and removing centering, shutting, strutting, propping etc., for Chajja ,Lintel and Copping cost of all materials, labour complete as per specifications. Specification | Cum | 4311.09 | 4311.09 | 2.61 | False | None | None | False | None | False | 11251.9449 | 0 | | 3820744 | 145358 | None | I No 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings | t | 93929.85 | 93929.85 | 2.86 | False | None | None | False | None | False | 268639.371 | 0 | | 3820745 | 145358 | None | I No 6.2 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8376.9 | 8376.9 | 22.71 | False | None | None | False | None | False | 190239.399 | 0 | | 3820746 | 145358 | None | I No 6.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1113.0 | 1113.0 | 18.29 | False | None | None | False | None | False | 20356.77 | 0 | | 3820747 | 145358 | None | I No 8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 331.5 | 331.5 | 221.6 | False | None | None | False | None | False | 73460.4 | 0 | | 3820748 | 145358 | None | I No 8.6.2 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 450.45 | 450.45 | 133.27 | False | None | None | False | None | False | 60031.4715 | 0 | | 3820749 | 145358 | None | I No 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 21.0 | False | None | None | False | None | False | 25247.25 | 0 | | 3820750 | 145358 | None | I No 9.38 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1461.6 | 1461.6 | 10.15 | False | None | None | False | None | False | 14835.24 | 0 | | 3820751 | 145358 | None | I No 10.14 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade co mplete | Sqm | 1161.3 | 1161.3 | 65.36 | False | None | None | False | None | False | 75902.568 | 0 | | 3820752 | 145358 | None | I No 8.63 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One coats on old work as per specifications and as per directions of Engineer in charge. | Sqm | 106.6 | 106.6 | 221.6 | False | None | None | False | None | False | 23622.56 | 0 | | 3820753 | 145358 | None | I No 8.73.1 | Finishing walls with textured exterior paint of required shade :Old work (Two coats on existing cement paint surface applied @ 3.28 ltr/10 m² including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. | Sqm | 280.8 | 280.8 | 133.27 | False | None | None | False | None | False | 37422.216 | 0 | | 3820754 | 145358 | None | I No 11.34 B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 280.8 | False | None | None | False | None | False | 53955.72 | 0 | | 3820755 | 145358 | None | I No 8.33.3 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 180.7 | 180.7 | 10.8 | False | None | None | False | None | False | 1951.56 | 0 | | 3820756 | 145358 | None | I No 12.31 | Providing Salwood frames of doors, windows, clerestory windows,ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 103755.75 | 103755.75 | 0.78 | False | None | None | False | None | False | 80929.485 | 0 | | 3820757 | 145358 | None | I No 12.15 | Providing and fixing in position fully panelled Honne wood shutters fordoors with stiles and rails of 40mm. thick with bottom and lock rails180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. | Sqm | 7816.2 | 7816.2 | 5.67 | False | None | None | False | None | False | 44317.854 | 0 | | 3820758 | 145358 | None | I No 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | m | 333.9 | 333.9 | 22.8 | False | None | None | False | None | False | 7612.92 | 0 | | 3820759 | 145358 | None | I NO 12.53 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles &
5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges. | Sqm | 1667.4 | 1667.4 | 6.3 | False | None | None | False | None | False | 10504.62 | 0 | | 3820760 | 145358 | None | I No 11.35.1.1 | Providing and fixing Aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. | Kg | 474.6 | 474.6 | 263.52 | False | None | None | False | None | False | 125066.592 | 0 | | 3820761 | 145358 | None | I No 15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/ Chajjas/ Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 857.85 | 857.85 | 57.0 | False | None | None | False | None | False | 48897.45 | 0 | | 3820762 | 145358 | None | I No 14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | No | 5128.2 | 5128.2 | 4.0 | False | None | None | False | None | False | 20512.8 | 0 | | 3820763 | 145358 | None | I No 14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :14.3.1 W.C. pan with ISI marked white solid plastic seat and lid | No | 6275.85 | 6275.85 | 1.0 | False | None | None | False | None | False | 6275.85 | 0 | | 3820764 | 145358 | None | I No 14.4.2 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 14.4.2 Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern | No | 7123.2 | 7123.2 | 1.0 | False | None | None | False | None | False | 7123.2 | 0 | | 3820765 | 145358 | None | I No 14.10.2.1 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 610x510 mm bowl depth 200 mm | No | 3806.25 | 3806.25 | 2.0 | False | None | None | False | None | False | 7612.5 | 0 | | 3820766 | 145358 | None | I No 1 | ASHIRVAD 25 mm dia 3 Long Commercial PVC Pipe Product id: 5116877-70595437069 CPVC 25mm Dia Pipe | No | 171.15 | 171.15 | 20.0 | False | None | None | False | None | False | 3423.0 | 0 | | 3820767 | 145358 | None | I No 2 | ASHIRVAD 50 mm dia 3 Long Commercial PVC Pipe Product id: 5116877-70595437069 CPVC 50mm Dia Pipe | No | 205.38 | 205.38 | 20.0 | False | None | None | False | None | False | 4107.6 | 0 | | 3820768 | 145358 | None | I No 3 | ASHIRVAD 15 mm dia 3 Long Commercial PVC Pipe Product id: 5116877-70595437069 CPVC 15mm Dia Pipe | No | 160.97 | 160.97 | 20.0 | False | None | None | False | None | False | 3219.4 | 0 | | 3820769 | 145358 | None | I No 647 | PVC pipe - OD 110mm and 6 Kg/sqcm | No | 267.75 | 267.75 | 20.0 | False | None | None | False | None | False | 5355.0 | 0 | | 3820770 | 145358 | None | I No 1.15.2 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m | Cum | 446.25 | 446.25 | 26.24 | False | None | None | False | None | False | 11709.6 | 0 | | 3820771 | 145358 | None | I No 2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 0.73 | False | None | None | False | None | False | 4341.456 | 0 | | 3820772 | 145358 | None | I No 2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates. | Cum | 6652.8 | 6652.8 | 6.5 | False | None | None | False | None | False | 43243.2 | 0 | | 3820773 | 145358 | None | I No 1 a | Providing and removing centering, shutting, strutting, propping etc., for Foundation cost of all materials, labour complete as per specifications. Specification | Cum | 532.22 | 532.22 | 0.73 | False | None | None | False | None | False | 388.5206 | 0 | | 3820774 | 145358 | None | I No 2 a | Providing and removing centering, shutting, strutting, propping etc., for Retaining wall cost of all materials, labour complete as per specifications. Specification | Cum | 665.28 | 665.28 | 4.86 | False | None | None | False | None | False | 3233.2608 | 0 | | 3820775 | 145358 | None | I No 3 a | Providing and removing centering, shutting, strutting, propping etc., for Slab cost of all materials, labour complete as per specifications. Specification | Cum | 3326.4 | 3326.4 | 0.91 | False | None | None | False | None | False | 3027.024 | 0 | | 3820776 | 145358 | None | I No 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings | t | 93929.85 | 93929.85 | 0.65 | False | None | None | False | None | False | 61054.4025 | 0 | | 3820777 | 145358 | None | I No 6.2 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8376.9 | 8376.9 | 1.38 | False | None | None | False | None | False | 11560.122 | 0 | | 3820778 | 145358 | None | I No 1.2.2 | Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick | m | 84.0 | 84.0 | 40.0 | False | None | None | False | None | False | 3360.0 | 0 | | 3820779 | 145358 | None | I No 1.5.2 | PVC/metal conduit Deep junction box. Supplying and fixing PVC/metal conduit Deep junction box | No | 53.55 | 53.55 | 3.0 | False | None | None | False | None | False | 160.65 | 0 | | 3820780 | 145358 | None | I No 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall | No | 341.25 | 341.25 | 2.0 | False | None | None | False | None | False | 682.5 | 0 | | 3820781 | 145358 | None | I No 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Modu | No | 381.15 | 381.15 | 2.0 | False | None | None | False | None | False | 762.3 | 0 | | 3820782 | 145358 | None | I No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 Sqmm | m | 42.0 | 42.0 | 20.0 | False | None | None | False | None | False | 840.0 | 0 | | 3820783 | 145358 | None | I No 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps one way | No | 92.4 | 92.4 | 1.0 | False | None | None | False | None | False | 92.4 | 0 | | 3820784 | 145358 | None | I No 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps two way | No | 159.6 | 159.6 | 1.0 | False | None | None | False | None | False | 159.6 | 0 | | 3820785 | 145358 | None | I No 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket | No | 170.1 | 170.1 | 1.0 | False | None | None | False | None | False | 170.1 | 0 | | 3820786 | 145358 | None | I No 3.14.6 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854 and IS 1293. 6A Bakelite Ceiling Rose 6A Lamp Holder | No | 66.15 | 66.15 | 2.0 | False | None | None | False | None | False | 132.3 | 0 | | 3820787 | 145358 | None | I No 11.3.2 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w | No | 777.0 | 777.0 | 1.0 | False | None | None | False | None | False | 777.0 | 0 | | 3820788 | 145358 | None | I No 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition | No | 876.75 | 876.75 | 2.0 | False | None | None | False | None | False | 1753.5 | 0 | | 3820789 | 145358 | None | I No 5.17.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps SP | No | 549.15 | 549.15 | 1.0 | False | None | None | False | None | False | 549.15 | 0 | | 3820790 | 145358 | None | I No 5.17.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps DP | No | 1158.15 | 1158.15 | 1.0 | False | None | None | False | None | False | 1158.15 | 0 | | 3820791 | 145358 | None | I No 3 a | Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm) | Km | 539742.0 | 539742.0 | 0.02 | False | None | None | False | None | False | 10794.84 | 0 | | 3820792 | 145358 | None | I No 112 | GESCOM DEPOSIT | No | 10000.0 | 10000.0 | 1.0 | False | None | None | False | None | False | 10000.0 | 0 |
|