3740362 | 139464 | None | 1.1 V-I | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. (Page No.5/Sl.No.1.1 Volume-1, SR of 2021-22) | Sqm | 72.1 | 72.1 | 337.0 | False | None | None | False | None | False | 24297.7 | 0 |
3740363 | 139464 | None | 1.14.1 V-I | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m (Page No.8 /Sl.No.1.14.1 Volume-1, SR of 2021-22) | Cum | 75.19 | 75.19 | 470.0 | False | None | None | False | None | False | 35339.3 | 0 |
3740364 | 139464 | None | 4.1 V-II | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/sqm including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. (Page No.5/Item No.4.1 Volume-2 SR of 2021-22) | Sqm | 97.85 | 97.85 | 317.0 | False | None | None | False | None | False | 31018.45 | 0 |
3740365 | 139464 | None | 2.1.2 V-I | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (Page No.15/Item No.2.1.2 Volume-2 SR of 2021-22) | Sqm | 5362.18 | 5362.18 | 40.0 | False | None | None | False | None | False | 214487.2 | 0 |
3740366 | 139464 | None | 11.32 V-II | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)(Page.84/I.No.11.32- 2021-22 Common SR for Buildings Vol-2+ (Corrigendum-3 dated.04.01.2023) | Tonne | 94760.0 | 94760.0 | 32.0 | False | None | None | False | None | False | 3032320.0 | 0 |
3740367 | 139464 | None | 2.2.2.1 V-1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No.15/Item No.2.2.2.1 Volume-2 SR of 2021-22+ Corrigendum 3) | Cum | 6651.04 | 6651.04 | 90.0 | False | None | None | False | None | False | 598593.6 | 0 |
3740368 | 139464 | None | 2.2.2.1 V-1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No.15/Item No.2.2.2.1 Volume-2 SR of 2021-22+ Corrigendum 3) | Cum | 6651.04 | 6651.04 | 5.0 | False | None | None | False | None | False | 33255.2 | 0 |
3740369 | 139464 | None | 5.2 V-II | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Page No.9 /Item No.5.2 Volume-2 SR of 2021-22) | Cum | 5709.29 | 5709.29 | 30.0 | False | None | None | False | None | False | 171278.7 | 0 |
3740370 | 139464 | None | 5.3 V-II | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Page No.9 /Item No.5.3 Volume-2 SR of 2021-22) | Cum | 5353.94 | 5353.94 | 25.0 | False | None | None | False | None | False | 133848.5 | 0 |
3740371 | 139464 | None | 1.9 V-I | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Page No.7 /Item No.1.9 Volume-2 SR of 2021-22 | Cum | 210.12 | 210.12 | 506.0 | False | None | None | False | None | False | 106320.72 | 0 |
3740372 | 139464 | None | 2.3.2 V-II | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No.16/Item No.2.3.2 Volume-2 SR of 2021-22+ Corrigendum 3) | Cum | 9242.19 | 9242.19 | 18.0 | False | None | None | False | None | False | 166359.42 | 0 |
3740373 | 139464 | None | 2.1.2 V-II | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (Page No.15/Item No.2.1.2 Volume-2 SR of 2021-22) | Cum | 5362.18 | 5362.18 | 35.0 | False | None | None | False | None | False | 187676.3 | 0 |
3740374 | 139464 | None | 2.5.2 V-II | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No.16/Item No.2.5.2 Volume-2 SR of 2021-22+ Corrigendum 3) Ground floor | Cum | 10831.69 | 10831.69 | 10.0 | False | None | None | False | None | False | 108316.9 | 0 |
3740375 | 139464 | None | 2.5.2 V-II | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No.16/Item No.2.5.2 Volume-2 SR of 2021-22+ Corrigendum 3) First floor | Cum | 10936.85 | 10936.85 | 9.0 | False | None | None | False | None | False | 98431.65 | 0 |
3740376 | 139464 | None | 2.5.2 V-II | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No.16/Item No.2.5.2 Volume-2 SR of 2021-22+ Corrigendum 3) Second floor | Cum | 11042.01 | 11042.01 | 2.0 | False | None | None | False | None | False | 22084.02 | 0 |
3740377 | 139464 | None | 6.33 V-II | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/cum and minimum compressive strength of 4.00 N/msqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page No.17 /Item No.6.33 Volume-2 SR of 2021-22) Ground floor | Sqm | 1092.83 | 1092.83 | 512.0 | False | None | None | False | None | False | 559528.96 | 0 |
3740378 | 139464 | None | 2.5.2 V-II | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/cum and minimum compressive strength of 4.00 N/msqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page No.17 /Item No.6.33 Volume-2 SR of 2021-22) First floor | Sqm | 1103.44 | 1103.44 | 564.0 | False | None | None | False | None | False | 622340.16 | 0 |
3740379 | 139464 | None | 2.5.2 V-II | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No.17/Item No.2.5.2 Volume-2 SR of 2021-22+Corrigendum 3) Ground Floor | Cum | 10194.53 | 10194.53 | 22.0 | False | None | None | False | None | False | 224279.66 | 0 |
3740380 | 139464 | None | 2.5.2 V-II | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No.17/Item No.2.5.2 Volume-2 SR of 2021-22+Corrigendum 3) First Floor | Cum | 10293.5 | 10293.5 | 23.0 | False | None | None | False | None | False | 236750.5 | 0 |
3740381 | 139464 | None | 2.5.2 V-II | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No.17/Item No.2.5.2 Volume-2 SR of 2021-22+Corrigendum 3) Ground Floor | Cum | 9557.37 | 9557.37 | 44.0 | False | None | None | False | None | False | 420524.28 | 0 |
3740382 | 139464 | None | 2.5.2 V-II | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No.17/Item No.2.5.2 Volume-2 SR of 2021-22+Corrigendum 3) First Floor | Cum | 9650.16 | 9650.16 | 44.0 | False | None | None | False | None | False | 424607.04 | 0 |
3740383 | 139464 | None | 2.5.2 V-II | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No.17/Item No.2.5.2 Volume-2 SR of 2021-22+Corrigendum 3) Second Floor | Cum | 9742.95 | 9742.95 | 6.0 | False | None | None | False | None | False | 58457.7 | 0 |
3740384 | 139464 | None | 2.5.2 V-II | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No.17/Item No.2.5.2 Volume-2 SR of 2021-22+Corrigendum 3) Ground Floor:- GF to FF Stairs | Cum | 9557.37 | 9557.37 | 14.0 | False | None | None | False | None | False | 133803.18 | 0 |
3740385 | 139464 | None | 2.5.2 V-II | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No.17/Item No.2.5.2 Volume-2 SR of 2021-22+Corrigendum 3) First Floor: | Cum | 9650.16 | 9650.16 | 23.0 | False | None | None | False | None | False | 221953.68 | 0 |
3740386 | 139464 | None | 6.33 V-II | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Page No.17 /Item No.6.33 Volume-2 SR of 2021-22) | Sqm | 1114.05 | 1114.05 | 139.0 | False | None | None | False | None | False | 154852.95 | 0 |
3740387 | 139464 | None | 8.3.1 V-II | Providing 20 mm cement plaster of mix :1:4 (1 ement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (Page No.41 /Item No.8.3.1 Volume-2 SR of 2021-22 + Corrigendum 3) Ground Floor:- | Sqm | 307.97 | 307.97 | 358.0 | False | None | None | False | None | False | 110253.26 | 0 |
3740388 | 139464 | None | 8.3.1 V-II | Providing 20 mm cement plaster of mix :1:4 (1 ement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (Page No.41 /Item No.8.3.1 Volume-2 SR of 2021-22 + Corrigendum 3) First Floor:- | Sqm | 310.96 | 310.96 | 364.0 | False | None | None | False | None | False | 113189.44 | 0 |
3740389 | 139464 | None | 8.3.1 V-II | Providing 20 mm cement plaster of mix :1:4 (1 ement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (Page No.41 /Item No.8.3.1 Volume-2 SR of 2021-22 + Corrigendum 3) Second Floor:- | Sqm | 313.95 | 313.95 | 296.0 | False | None | None | False | None | False | 92929.2 | 0 |
3740390 | 139464 | None | 8.1.2 V-II | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifiations and as per directions of Engineer-in-charge (Page No.43 /Item No.8.1.2 Volume-2 SR of 2021-22 + Corrigendum 3) Ground Floor:- Staff area | Sqm | 203.94 | 203.94 | 270.0 | False | None | None | False | None | False | 55063.8 | 0 |
3740391 | 139464 | None | 8.1.2 V-II | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifiations and as per directions of Engineer-in-charge (Page No.43 /Item No.8.1.2 Volume-2 SR of 2021-22 + Corrigendum 3) First Floor:- Staff area | Sqm | 205.92 | 205.92 | 270.0 | False | None | None | False | None | False | 55598.4 | 0 |
3740392 | 139464 | None | 8.1.2 V-II | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifiations and as per directions of Engineer-in-charge (Page No.43 /Item No.8.1.2 Volume-2 SR of 2021-22 + Corrigendum 3) Second Floor:- Staff area | Sqm | 207.9 | 207.9 | 33.0 | False | None | None | False | None | False | 6860.7 | 0 |
3740393 | 139464 | None | 8.8 V-II | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (Page No.42 /Item No.8.8 Volume-2 SR of 2021-22 + Corrigendum 3)Ground Floor | Sqm | 316.21 | 316.21 | 785.0 | False | None | None | False | None | False | 248224.85 | 0 |
3740394 | 139464 | None | 8.8 V-II | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (Page No.42 /Item No.8.8 Volume-2 SR of 2021-22 + Corrigendum 3) First Floor | Sqm | 319.28 | 319.28 | 785.0 | False | None | None | False | None | False | 250634.8 | 0 |
3740395 | 139464 | None | 8.8 V-II | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (Page No.42 /Item No.8.8 Volume-2 SR of 2021-22 + Corrigendum 3) Second Floor | Sqm | 322.35 | 322.35 | 76.0 | False | None | None | False | None | False | 24498.6 | 0 |
3740396 | 139464 | None | 2.5.2 V-II | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.(Page No.23 /Item No.2.5.2 Volume-2 SR of 2021-22) | Cum | 2097.68 | 2097.68 | 8.0 | False | None | None | False | None | False | 16781.44 | 0 |
3740397 | 139464 | None | 9.39 V-II | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (Page No.65 /Item No.9.39 Volume-2 SR of 2021-22 + Corrigendum) Ground Floor | Sqm | 1003.22 | 1003.22 | 128.0 | False | None | None | False | None | False | 128412.16 | 0 |
3740398 | 139464 | None | 9.39 V-II | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (Page No.65 /Item No.9.39 Volume-2 SR of 2021-22 + Corrigendum) First Floor | Sqm | 1012.96 | 1012.96 | 128.0 | False | None | None | False | None | False | 129658.88 | 0 |
3740399 | 139464 | None | 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete Size of Tile 600x600 mm (Page No.61 /Item No.9.17.2 Volume-2 SR of 2021-22 + Corrigendum) Ground Floor | Sqm | 1135.06 | 1135.06 | 284.0 | False | None | None | False | None | False | 322357.04 | 0 |
3740400 | 139464 | None | 9.17.2 V_II | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete Size of Tile 600x600 mm (Page No.61 /Item No.9.17.2 Volume-2 SR of 2021-22 + Corrigendum) First Floor | Sqm | 1146.08 | 1146.08 | 288.0 | False | None | None | False | None | False | 330071.04 | 0 |
3740401 | 139464 | None | 9.17.2 V_II | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete Size of Tile 600x600 mm (Page No.61 /Item No.9.17.2 Volume-2 SR of 2021-22 + Corrigendum) Second Floor | Sqm | 1157.1 | 1157.1 | 13.0 | False | None | None | False | None | False | 15042.3 | 0 |
3740402 | 139464 | None | 9.20.5 V-II | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x1200 mm (Page No.62 /Item No.9.20.5 Volume-2 SR of 2021-22 + Corrigendum) Ground Floor | Sqm | 92.7 | 92.7 | 284.0 | False | None | None | False | None | False | 26326.8 | 0 |
3740403 | 139464 | None | 9.20.5 V-II | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x1200 mm (Page No.62 /Item No.9.20.5 Volume-2 SR of 2021-22 + Corrigendum) First Floor | Sqm | 93.6 | 93.6 | 288.0 | False | None | None | False | None | False | 26956.8 | 0 |
3740404 | 139464 | None | 9.20.5 V-II | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x1200 mm (Page No.62 /Item No.9.20.5 Volume-2 SR of 2021-22 + Corrigendum) Second Floor | Sqm | 94.5 | 94.5 | 13.0 | False | None | None | False | None | False | 1228.5 | 0 |
3740405 | 139464 | None | 9.24 V-II | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent (Page No.63 / Item No.9.24 Volume-2 SR of 2021-22 + Corrigendum) Ground Floor | Sqm | 2956.1 | 2956.1 | 53.0 | False | None | None | False | None | False | 156673.3 | 0 |
3740406 | 139464 | None | 9.24 V-II | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent (Page No.63 / Item No.9.24 Volume-2 SR of 2021-22 + Corrigendum) First Floor | Sqm | 2984.8 | 2984.8 | 54.0 | False | None | None | False | None | False | 161179.2 | 0 |
3740407 | 139464 | None | 8.51 v-II | Providing and applying white cement based putty of averagethickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Page No.50 /Item No.8.51 Volume-2 SR of 2021-22) Ground Floor | Sqm | 80.34 | 80.34 | 1059.0 | False | None | None | False | None | False | 85080.06 | 0 |
3740408 | 139464 | None | 8.51 v-II | Providing and applying white cement based putty of averagethickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Page No.50 /Item No.8.51 Volume-2 SR of 2021-22) First Floor | Sqm | 81.12 | 81.12 | 1059.0 | False | None | None | False | None | False | 85906.08 | 0 |
3740409 | 139464 | None | 8.51 v-II | Providing and applying white cement based putty of averagethickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Page No.50 /Item No.8.51 Volume-2 SR of 2021-22) Second Floor | Sqm | 81.9 | 81.9 | 109.0 | False | None | None | False | None | False | 8927.1 | 0 |
3740410 | 139464 | None | 8.55.2 V-II | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. (Page No.51 /Item No.8.55.2 Volume-2 SR of 2021-22) Ground Floor | Sqm | 41.2 | 41.2 | 1062.0 | False | None | None | False | None | False | 43754.4 | 0 |
3740411 | 139464 | None | 8.55.2 V-II | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. (Page No.51 /Item No.8.55.2 Volume-2 SR of 2021-22) First Floor | Sqm | 41.6 | 41.6 | 1062.0 | False | None | None | False | None | False | 44179.2 | 0 |
3740412 | 139464 | None | 8.55.2 V-II | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. (Page No.51 /Item No.8.55.2 Volume-2 SR of 2021-22) Second Floor | Sqm | 42.0 | 42.0 | 109.0 | False | None | None | False | None | False | 4578.0 | 0 |
3740413 | 139464 | None | 8.33.1 V-ii | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls at 1.25 ltr-10 m over and including one coat of Special primer applied @ 0.75 ltr-10 m with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Page No.46 /Item No.8.33.1 Volume-2 SR of 2021-22) Ground Floor | Sqm | 121.54 | 121.54 | 1059.0 | False | None | None | False | None | False | 128710.86 | 0 |
3740414 | 139464 | None | 8.33.1 V-ii | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls at 1.25 ltr-10 m over and including one coat of Special primer applied @ 0.75 ltr -10 m with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Page No.46 /Item No.8.33.1 Volume-2 SR of 2021-22) First Floor | Sqm | 122.72 | 122.72 | 1062.0 | False | None | None | False | None | False | 130328.64 | 0 |
3740415 | 139464 | None | 109 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr-10 m over and including one coat of Special primer applied @ 0.75 ltr -10 m with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Page No.46 /Item No.8.33.1 Volume-2 SR of 2021-22) Second Floor | Sqm | 123.9 | 123.9 | 109.0 | False | None | None | False | None | False | 13505.1 | 0 |
3740416 | 139464 | None | 8.29 V-II | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m) over and including priming coat of exterior primer applied @ 2.20kg/10 m to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (Page No.45 /Item No.8.29 Volume-2 SR of 2021-22) Ground Floor:- | Sqm | 214.24 | 214.24 | 356.0 | False | None | None | False | None | False | 76269.44 | 0 |
3740417 | 139464 | None | 8.29 V-II | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m) over and including priming coat of exterior primer applied @ 2.20kg/10 m to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (Page No.45 /Item No.8.29 Volume-2 SR of 2021-22) First Floor:- | Sqm | 216.32 | 216.32 | 356.0 | False | None | None | False | None | False | 77009.92 | 0 |
3740418 | 139464 | None | 8.29 V-II | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m) over and including priming coat of exterior primer applied @ 2.20kg/10 m to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (Page No.45 /Item No.8.29 Volume-2 SR of 2021-22) Second Floor:- | Sqm | 218.4 | 218.4 | 296.0 | False | None | None | False | None | False | 64646.4 | 0 |
3740419 | 139464 | None | 4.5 V-II | Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. (Page No.5/Item No.4.5 Volume-2 SR of 2021-22). (Page No.5/Item No.4.5 Volume-2 SR of 2021-22) Ground Floor | Mtr | 361.53 | 361.53 | 31.0 | False | None | None | False | None | False | 11207.43 | 0 |
3740420 | 139464 | None | 4.5 V-II | Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. (Page No.5/Item No.4.5 Volume-2 SR of 2021-22). (Page No.5/Item No.4.5 Volume-2 SR of 2021-22) First Floor | Mtr | 365.15 | 365.15 | 44.0 | False | None | None | False | None | False | 16066.6 | 0 |
3740421 | 139464 | None | 12.90 V-II | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) (Page No.112 /Item No.12.90 Volume-2 SR of 2021-22) Ground Floor | Sqm | 7457.2 | 7457.2 | 24.0 | False | None | None | False | None | False | 178972.8 | 0 |
3740422 | 139464 | None | 12.90 V-II | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) (Page No.112 /Item No.12.90 Volume-2 SR of 2021-22) First Floor | Sqm | 7531.77 | 7531.77 | 32.0 | False | None | None | False | None | False | 241016.64 | 0 |
3740423 | 139464 | None | 12.90 V-II | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Page No.112 /Item No.12.90 Volume-2 SR of 2021-22) Second Floor | Sqm | 7606.34 | 7606.34 | 5.0 | False | None | None | False | None | False | 38031.7 | 0 |
3740424 | 139464 | None | 12.85 V-II | Providing & fixing of louvered ventilator made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) (Page No.110 /Item No.12.85 Volume-2 SR of 2021-22) Ground Floor | Sqm | 5016.1 | 5016.1 | 2.0 | False | None | None | False | None | False | 10032.2 | 0 |
3740425 | 139464 | None | 12.85 V-II | Providing & fixing of louvered ventilator made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Page No.110 /Item No.12.85 Volume-2 SR of 2021-22) First Floor | Sqm | 5066.26 | 5066.26 | 2.0 | False | None | None | False | None | False | 10132.52 | 0 |
3740426 | 139464 | None | 11.28 V-II | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts) bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Page No.83 /Item No.11.28 Volume-2 SR of 2021-22) Ground Floor | Kgs | 515.0 | 515.0 | 235.0 | False | None | None | False | None | False | 121025.0 | 0 |
3740427 | 139464 | None | 11.28 V-II | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts) bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Page No.83 /Item No.11.28 Volume-2 SR of 2021-22) First Floor | Kgs | 520.15 | 520.15 | 164.0 | False | None | None | False | None | False | 85304.6 | 0 |
3740428 | 139464 | None | 11.34. B V-II | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc (Page No.85 /Item No.11.34.B Volume-2 SR of 2021-22) Ground Floor | Mtr | 161.71 | 161.71 | 2304.0 | False | None | None | False | None | False | 372579.84 | 0 |
3740429 | 139464 | None | 11.34. B V-II | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc (Page No.85 /Item No.11.34.B Volume-2 SR of 2021-22) First Floor | Mtr | 163.28 | 163.28 | 2562.0 | False | None | None | False | None | False | 418323.36 | 0 |
3740430 | 139464 | None | 11.34. B V-II | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc (Page No.85 /Item No.11.34.B Volume-2 SR of 2021-22) Second Floor | Mtr | 164.85 | 164.85 | 349.0 | False | None | None | False | None | False | 57532.65 | 0 |
3740431 | 139464 | None | 15.1 V-II | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/ Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge (Page No.133 / Item No.15.1 Volume-2 SR of 2021-22) | Sqm | 782.7 | 782.7 | 385.0 | False | None | None | False | None | False | 301339.5 | 0 |
3740432 | 139464 | None | 3.9 V-I | Providing Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour and usage charges of machinery complete as per the direction of engineer incharge of work. (Page No.23 / Item No.3.9 Volume-1 SR of 2021-22) | Cum | 4795.99 | 4795.99 | 24.0 | False | None | None | False | None | False | 115103.76 | 0 |
3740433 | 139464 | None | code72 | Providing, supplying, cutting and fixing frame with shutters, combination of solid wood handles with lock, hinges, door stopper, tower bolts, aldrops, handles, alround shutters, lipping, wooden beading, shutter frame melamine polish, door closers, necessary glass fitting for shutters with beading, shutter thickness of 32mm etc., complete inlcuding cost and conveyance of all materials, labour for all items of work, HOM of machinery and equipment with all lead and lift, loading and unloading, transportation and all other incidental charges etc., complete as per directions of the Engineer-in-charge of the work. Ground Floor & First Floor | Sqm | 10000.0 | 10000.0 | 21.0 | False | None | None | False | None | False | 210000.0 | 0 |
3740434 | 139464 | None | 12.1, 12.3 & 12.4 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete . 4 Kg/m2: (Page No.139 /Sl.No.12.1, 12.3 & 12.4 Volume-V SR of 2021-22) 63mm(weight of pipe-0.465 kg) (Code.M150A) | Mtr | 124.63 | 124.63 | 15.0 | False | None | None | False | None | False | 1869.45 | 0 |
3740435 | 139464 | None | 12.1, 12.3 & 12.4 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete . 4 Kg/m2: (Page No.139 /Sl.No.12.1, 12.3 & 12.4 Volume-V SR of 2021-22) 90mm(weight of pipe -0.917 kg) (Code.M150C) | Mtr | 225.57 | 225.57 | 78.0 | False | None | None | False | None | False | 17594.46 | 0 |
3740436 | 139464 | None | 12.1, 12.3 & 12.4 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete . 4 Kg/m2: (Page No.139 /Sl.No.12.1, 12.3 & 12.4 Volume-V SR of 2021-22) 110mm(weight of pipe-1.315 kg) (Code.M150D) | Mtr | 307.97 | 307.97 | 108.0 | False | None | None | False | None | False | 33260.76 | 0 |
3740437 | 139464 | None | 14.5 V-V | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete 8 Kg/m2: (Page No.140 /Sl.No.14.5 Volume-V SR of 2021-22) 160mm(weight of pipe -3.923 kg) (Code.M150 T) | Mtr | 962.02 | 962.02 | 30.0 | False | None | None | False | None | False | 28860.6 | 0 |
3740438 | 139464 | None | 13.32.4 & 13.32.5 | Providing and fixing Chorinated poly venyl chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete (Concealed work including cutting chases and good the walls etc.,) (Item No.13.32.4 & 13.32.5 Volume-2 SR of 2021-22 Corrigendum dated:21.04.2022) 32mm nominal dia Pipes | Mtr | 572.68 | 572.68 | 200.0 | False | None | None | False | None | False | 114536.0 | 0 |
3740439 | 139464 | None | 13.32.4 & 13.32.5 | Providing and fixing Chorinated poly venyl chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete (Concealed work including cutting chases and good the walls etc.,) (Item No.13.32.4 & 13.32.5 Volume-2 SR of 2021-22 Corrigendum dated:21.04.2022) 25mm nominal dia Pipes | Mtr | 490.28 | 490.28 | 120.0 | False | None | None | False | None | False | 58833.6 | 0 |
3740440 | 139464 | None | 13.33.6 & 13.33.4 | Providing and fixing Chorinated poly venyl chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per directions of the Engineer-in-charge of the work. External work. (Item No.13.33.6 & 13.33.4 Volume-2 SR of 2021-22 Corrigendum dated:21.04.2022) 50mm nominal dia Pipes | Mtr | 723.06 | 723.06 | 150.0 | False | None | None | False | None | False | 108459.0 | 0 |
3740441 | 139464 | None | 13.33.6 & 13.33.4 | Providing and fixing Chorinated poly venyl chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per directions of the Engineer-in-charge of the work. External work. (Item No.13.33.6 & 13.33.4 Volume-2 SR of 2021-22 Corrigendum dated:21.04.2022) 32mm nominal dia Pipes | Mtr | 368.74 | 368.74 | 150.0 | False | None | None | False | None | False | 55311.0 | 0 |
3740442 | 139464 | None | 9.7 & 9.8 | Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (Page No.138 /Sl.No.9.7 & 9.8 Volume-V SR of 2021-22)90 mm dia PVC BEND (Code.M 120 G) | Nos | 419.21 | 419.21 | 10.0 | False | None | None | False | None | False | 4192.1 | 0 |
3740443 | 139464 | None | 9.7 & 9.8 | Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (Page No.138 /Sl.No.9.7 & 9.8 Volume-V SR of 2021-22)90 mm dia PVC BEND (Code.M 120 G)110 mm dia PVC BEND (Code.M 120 H) | Nos | 528.39 | 528.39 | 10.0 | False | None | None | False | None | False | 5283.9 | 0 |
3740444 | 139464 | None | 7.4, 7.7 & 7.8 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments. (Page No.138 /Sl.No.7.4, 7.7, 7.8 Volume-V SR of 2021-22) 110 mm dia PVC Elbows (Code M100 H) | Nos | 324.45 | 324.45 | 100.0 | False | None | None | False | None | False | 32445.0 | 0 |
3740445 | 139464 | None | 7.4, 7.7 & 7.8 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments. (Page No.138 /Sl.No.7.4, 7.7, 7.8 Volume-V SR of 2021-22) 90 mm dia PVC Elbows (Code M100 G) | Nos | 296.64 | 296.64 | 38.0 | False | None | None | False | None | False | 11272.32 | 0 |
3740446 | 139464 | None | 7.4, 7.7 & 7.8 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments. (Page No.138 /Sl.No.7.4, 7.7, 7.8 Volume-V SR of 2021-22) 50 mm dia PVC Elbows (Code M100 D) | Nos | 71.07 | 71.07 | 21.0 | False | None | None | False | None | False | 1492.47 | 0 |
3740447 | 139464 | None | 11.8, 11.7 & 11.4 | Supply and delivery at site special moulded variety PVC reducer as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (Page No.139 /Sl.No.11.8, 11.7, 11.4 Volume-V SR of 2021-22) 110 mm dia PVC REDUCER (Code M140 H) | Nos | 280.16 | 280.16 | 40.0 | False | None | None | False | None | False | 11206.4 | 0 |
3740448 | 139464 | None | 11.8, 11.7 & 11.4 | Supply and delivery at site special moulded variety PVC reducer as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (Page No.139 /Sl.No.11.8, 11.7, 11.4 Volume-V SR of 2021-22) 90 mm dia PVC REDUCER (Code M140 G) | Nos | 158.62 | 158.62 | 40.0 | False | None | None | False | None | False | 6344.8 | 0 |
3740449 | 139464 | None | 11.8, 11.7 & 11.4 | Supply and delivery at site special moulded variety PVC reducer as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (Page No.139 /Sl.No.11.8, 11.7, 11.4 Volume-V SR of 2021-22) 50 mm dia PVC REDUCER (Code M140 D) | Nos | 63.86 | 63.86 | 40.0 | False | None | None | False | None | False | 2554.4 | 0 |
3740450 | 139464 | None | 8.7 & 8.8 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (Page No.137 /Sl.No.8.7 & 8.8 Volume-V SR of 2021-22)90 mm dia PVC Tee (Code M110 G) | Nos | 183.34 | 183.34 | 50.0 | False | None | None | False | None | False | 9167.0 | 0 |
3740451 | 139464 | None | 8.7 & 8.8 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (Page No.137 /Sl.No.8.7 & 8.8 Volume-V SR of 2021-22)110 mm dia PVC Tee (Code M110 H) | Nos | 269.86 | 269.86 | 50.0 | False | None | None | False | None | False | 13493.0 | 0 |
3740452 | 139464 | None | 13.8.2.2 | Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length 20 mm nominal bore (Page No.116 /Item No.13.8.2.2 Volume-2 SR of 2021-22) | Nos | 130.81 | 130.81 | 16.0 | False | None | None | False | None | False | 2092.96 | 0 |
3740453 | 139464 | None | 13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid (Page No.118 /Item No.13.22.2 Volume-2 SR of 2021-22) | Nos | 218.36 | 218.36 | 16.0 | False | None | None | False | None | False | 3493.76 | 0 |
3740454 | 139464 | None | 13.24 | Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 g (Page No.118 /Item No.13.24 Volume-2 SR of 2021-22) | Nos | 224.54 | 224.54 | 12.0 | False | None | None | False | None | False | 2694.48 | 0 |
3740455 | 139464 | None | 13.4.6 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore (Page No.115/Item No.13.4.6 Volume-2 SR of 2021-22) | Nos | 2117.68 | 2117.68 | 14.0 | False | None | None | False | None | False | 29647.52 | 0 |
3740456 | 139464 | None | 14.5.1 V-II | Providing and fixing white vitreous china flat back half stall urinal of size 580x 380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls andfloors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern (Page No.124 /Item No.14.5.1, Volume-2 SR of 2021-22) | Nos | 6826.84 | 6826.84 | 4.0 | False | None | None | False | None | False | 27307.36 | 0 |
3740457 | 139464 | None | 14.7.3 v-ii | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps (Page No.125 /Item No.14.7.3 Volume-2 SR of 2021-22) | Nos | 2604.87 | 2604.87 | 6.0 | False | None | None | False | None | False | 15629.22 | 0 |
3740458 | 139464 | None | 10.8 V-II | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. (Page No.70 /Item No.10.8 Volume-2 SR of 2021-22) | Sqm | 1660.36 | 1660.36 | 2.1 | False | None | None | False | None | False | 3486.756 | 0 |
3740459 | 139464 | None | 14.3 V-II | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (Page No.123 /Item No.14.3, Volume-2 SR of 2021-22) | Nos | 5155.15 | 5155.15 | 4.0 | False | None | None | False | None | False | 20620.6 | 0 |
3740460 | 139464 | None | 14.7 | Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. s (Page No.125 /Item No.14.7BVolume-2 SR of 2021-22) | Nos | 1776.75 | 1776.75 | 8.0 | False | None | None | False | None | False | 14214.0 | 0 |
3740461 | 139464 | None | 14.42 v-ii | Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes, weighing not less than 60 g. (Page No.130 /Item No.14.42, Volume-2 SR of 2021-22) | Nos | 249.26 | 249.26 | 4.0 | False | None | None | False | None | False | 997.04 | 0 |
3740462 | 139464 | None | 14.22 A V-II | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (Page No.127 /Item No.14.22A Volume-2 SR of 2021-22) | Nos | 985.71 | 985.71 | 6.0 | False | None | None | False | None | False | 5914.26 | 0 |
3740463 | 139464 | None | 14.47 V-II | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. (Page No.130 /Item No.14.47 Volume-2 SR of 2021-22) | Nos | 14102.76 | 14102.76 | 2.0 | False | None | None | False | None | False | 28205.52 | 0 |
3740464 | 139464 | None | 13.48 V-II | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type-A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion (i) Single socketed pipes 100mm diameter. (Item No.13.48 Volume-2 SR of 2021-22 Corrigendum dated:21.04.2022) | Mtr | 260.59 | 260.59 | 20.0 | False | None | None | False | None | False | 5211.8 | 0 |
3740465 | 139464 | None | 13.34 V-II | Providing and placing on terrace (at all floor levels) Polyethylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fitting and the base support for tank. (Item No.13.34 Volume-2 SR of 2021-22 Corrigendum dated:21.04.2022) | Ltr | 8.24 | 8.24 | 4000.0 | False | None | None | False | None | False | 32960.0 | 0 |
3740466 | 139464 | None | 1.2.2 | ELECTRICAL WORKS: Conceiled Conduit System upplying heavy gauge PVC conduit pipe dia confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. (Page No.1/Item No. 1.2 Ele. SR of 2021-22) 25mm dia 2mm thick. (Item No.1.2.2) | Mtr | 70.0 | 70.0 | 900.0 | False | None | None | False | None | False | 63000.0 | 0 |
3740467 | 139464 | None | 1.2.3 | Conceiled Conduit System upplying heavy gauge PVC conduit pipe dia confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. (Page No.1/Item No. 1.2 Ele. SR of 2021-22) 32 mm dia 2mm thick. (Item No.1.2.3) | Mtr | 93.0 | 93.0 | 100.0 | False | None | None | False | None | False | 9300.0 | 0 |
3740468 | 139464 | None | 1.5.2 | Supplying and fixing PVC/metal conduit Deep junction box.25mm deep junction box (Page No.2/Item No.1.5.2 Ele. SR of 2021-22) | Sqm | 51.0 | 51.0 | 180.0 | False | None | None | False | None | False | 9180.0 | 0 |
3740469 | 139464 | None | 1.12 | Supplying And Fixing Metal Fan Box with Round Hook. (Page No.2/Item No.1.12 Ele. SR of 2021-22) | Nos | 163.0 | 163.0 | 30.0 | False | None | None | False | None | False | 4890.0 | 0 |
3740470 | 139464 | None | 1.3 | Supplying heavy gauge PVC Conduit Pipe dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (Page No.1/ Item No.1.3 Ele. SR of 2021-22) 25mm dia 2mm thick. (Item No.1.2.2) | Mtr | 80.0 | 80.0 | 500.0 | False | None | None | False | None | False | 40000.0 | 0 |
3740471 | 139464 | None | 1.3 | Supplying heavy gauge PVC Conduit Pipe dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (Page No.1/ Item No.1.3 Ele. SR of 2021-22) 25mm dia 2mm thick. (Item No.1.2.2) | Mtr | 80.0 | 80.0 | 500.0 | False | None | None | False | None | False | 40000.0 | 0 |
3740472 | 139464 | None | 1.2.3 | Supplying heavy gauge PVC Conduit Pipe dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (Page No.1/ Item No.1.3 Ele. SR of 2021-22) 32 mm dia 2mm thick. (Item No.1.2.3) | Mtr | 105.0 | 105.0 | 60.0 | False | None | None | False | None | False | 6300.0 | 0 |
3740473 | 139464 | None | 12.2.3 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. (Page No.39 /Item No.12.2.3 Ele. SR of 2021-22) | Nos | 1115.0 | 1115.0 | 3.0 | False | None | None | False | None | False | 3345.0 | 0 |
3740474 | 139464 | None | 2.2.2 & 2.2.3 | Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet. Using class A Materials . (Page No.3 /Item No. 2.2.2 & 2.2.3 Ele. SR of 2021-22) | Point | 386.0 | 386.0 | 25.0 | False | None | None | False | None | False | 9650.0 | 0 |
3740475 | 139464 | None | 2.2.2 & 2.2.3 | Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet. Using class A Materials . (Page No.3 /Item No. 2.2.2 & 2.2.3 Ele. SR of 2021-22) Above 6Mtr up to 10Mtr from tapping Point to out let via switch. | Point | 567.0 | 567.0 | 100.0 | False | None | None | False | None | False | 56700.0 | 0 |
3740476 | 139464 | None | 1.9.2 | Supplying PVC/GI flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 25mm (Page No.2 /Item No. 1.9.2 Ele. SR of 2021-22) | Mtr | 32.0 | 32.0 | 250.0 | False | None | None | False | None | False | 8000.0 | 0 |
3740477 | 139464 | None | 2.3.2 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. Group "A" (Page No.3 /Item No.2.3 Electrical SR of 2022-23) 1.5 sqmm (2.3.2) | Mtr | 26.0 | 26.0 | 1050.0 | False | None | None | False | None | False | 27300.0 | 0 |
3740478 | 139464 | None | 2.3.3 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. Group "A" (Page No.3 /Item No.2.3 Electrical SR of 2022-23) 2.5 sqmm (2.3.3) | Mtr | 40.0 | 40.0 | 1800.0 | False | None | None | False | None | False | 72000.0 | 0 |
3740479 | 139464 | None | 2.3.4 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. Group "A" (Page No.3 /Item No.2.3 Electrical SR of 2022-23) 4 sqmm (2.3.4) | Mtr | 59.0 | 59.0 | 900.0 | False | None | None | False | None | False | 53100.0 | 0 |
3740480 | 139464 | None | 2.3.5 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. Group "A" (Page No.3 /Item No.2.3 Electrical SR of 2022-23) 6 sqmm.(2.3.5) | Mtr | 87.0 | 87.0 | 495.0 | False | None | None | False | None | False | 43065.0 | 0 |
3740481 | 139464 | None | 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (Page No.3 /Item No.3.4 Electrical SR of 2022-23) 1-3 Way (3.4.1) | Nos | 123.0 | 123.0 | 10.0 | False | None | None | False | None | False | 1230.0 | 0 |
3740482 | 139464 | None | 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (Page No.3 /Item No.3.4 Electrical SR of 2022-23) 4-5 Way (3.4.2) | Nos | 138.0 | 138.0 | 5.0 | False | None | None | False | None | False | 690.0 | 0 |
3740483 | 139464 | None | 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (Page No.3 /Item No.3.4 Electrical SR of 2022-23) 4-5 Way (3.4.2) | Nos | 138.0 | 138.0 | 5.0 | False | None | None | False | None | False | 690.0 | 0 |
3740484 | 139464 | None | 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (Page No.3 /Item No.3.4 Electrical SR of 2022-23) 8 Way (3.4.4) | Nos | 250.0 | 250.0 | 13.0 | False | None | None | False | None | False | 3250.0 | 0 |
3740485 | 139464 | None | 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (Page No.3 /Item No.3.4 Electrical SR of 2022-23) 10-12 Way (3.4.5) | Nos | 325.0 | 325.0 | 25.0 | False | None | None | False | None | False | 8125.0 | 0 |
3740486 | 139464 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (Page No.3 /Item No.3.4 Electrical SR of 2022-23) 16-18 Way (3.4.6) | Nos | 354.0 | 354.0 | 10.0 | False | None | None | False | None | False | 3540.0 | 0 |
3740487 | 139464 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (Page No.3 /Item No.3.5 Electrical SR of 2022-23) 1 to 3 Module. (Item No.3.5.1) | Nos | 152.0 | 152.0 | 10.0 | False | None | None | False | None | False | 1520.0 | 0 |
3740488 | 139464 | None | 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (Page No.3 /Item No.3.5 Electrical SR of 2022-23) 4 Moudule.(Item No.3.5.2) | Nos | 175.0 | 175.0 | 5.0 | False | None | None | False | None | False | 875.0 | 0 |
3740489 | 139464 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (Page No.3 /Item No.3.5 Electrical SR of 2022-23) 8 Module. (Item No.3.5.4) | Nos | 302.0 | 302.0 | 13.0 | False | None | None | False | None | False | 3926.0 | 0 |
3740490 | 139464 | None | 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (Page No.3 /Item No.3.5 Electrical SR of 2022-23) 12 Module. (Item No.3.5.5) | Nos | 363.0 | 363.0 | 30.0 | False | None | None | False | None | False | 10890.0 | 0 |
3740491 | 139464 | None | 3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (Page No.3 /Item No.3.5 Electrical SR of 2022-23) 18 Module. (Item No.3.5.6) | Nos | 363.0 | 363.0 | 10.0 | False | None | None | False | None | False | 3630.0 | 0 |
3740492 | 139464 | None | 3.6 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293. Using Group "A" materials (Page No.3 /Item No.3.6 Electrical SR of 2022-23) 6 Amps one way. | Nos | 88.0 | 88.0 | 300.0 | False | None | None | False | None | False | 26400.0 | 0 |
3740493 | 139464 | None | 3.6 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293. Using Group "A" materials (Page No.3 /Item No.3.6 Electrical SR of 2022-23) 6Amps 3way socket. | Nos | 152.0 | 152.0 | 4.0 | False | None | None | False | None | False | 608.0 | 0 |
3740494 | 139464 | None | 3.6 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293. Using Group "A" materials (Page No.3 /Item No.3.6 Electrical SR of 2022-23) Stepped Fan Regulator. | Nos | 162.0 | 162.0 | 125.0 | False | None | None | False | None | False | 20250.0 | 0 |
3740495 | 139464 | None | 3.6 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293. Using Group "A" materials (Page No.3 /Item No.3.6 Electrical SR of 2022-23) 32Amps DP switch. | Nos | 375.0 | 375.0 | 23.0 | False | None | None | False | None | False | 8625.0 | 0 |
3740496 | 139464 | None | 3.6 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293. Using Group "A" materials (Page No.3 /Item No.3.6 Electrical SR of 2022-23) 6/16Amps universal socket. | Nos | 249.0 | 249.0 | 23.0 | False | None | None | False | None | False | 5727.0 | 0 |
3740497 | 139464 | None | 001 | Supplying and fixing regular MCB Distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG M.S enclosure. Double Door 4 Way TP & N | Nos | 3053.0 | 3053.0 | 3.0 | False | None | None | False | None | False | 9159.0 | 0 |
3740498 | 139464 | None | 002 | Supplying and fixing regular MCB Distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG M.S enclosure. Double Door 8 Way TP & N | Nos | 4136.0 | 4136.0 | 3.0 | False | None | None | False | None | False | 12408.0 | 0 |
3740499 | 139464 | None | 5.17.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. (Page No.13 / Item No.5.17 Electrical SR of 2022-23) 5-32 Amps DP (Item 5.17.4) | Nos | 1103.0 | 1103.0 | 42.0 | False | None | None | False | None | False | 46326.0 | 0 |
3740500 | 139464 | None | 5.17.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. (Page No.13 / Item No.5.17 Electrical SR of 2022-23) 40-63Amps TP&N. (Item 5.17.9) | Nos | 2399.0 | 2399.0 | 6.0 | False | None | None | False | None | False | 14394.0 | 0 |
3740501 | 139464 | None | 11.10.5 | Supplying & fixing of Surface mounting type retrofit type -LED tube .. W comprising of LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. Polycarbonate/OPAL Acrylic Casing. 8W-20W (T8) (Page No.37 / Item No.11.10.5 Electrical SR of 2022-23) | Nos | 622.0 | 622.0 | 116.0 | False | None | None | False | None | False | 72152.0 | 0 |
3740502 | 139464 | None | 11.14.2 | Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. (Page No.37 / Item No.11.14.2 Electrical SR of 2022-23) 1 x 4' Tube light fitting. | Nos | 324.0 | 324.0 | 60.0 | False | None | None | False | None | False | 19440.0 | 0 |
3740503 | 139464 | None | 11.14.2 | Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. (Page No.37 / Item No.11.14.2 Electrical SR of 2022-23) Excluding Ballast & Fluorescent Tube 2 x 4' Tube light fitting. | Nos | 390.0 | 390.0 | 28.0 | False | None | None | False | None | False | 10920.0 | 0 |
3740504 | 139464 | None | 11.6.2 | Supply of 2'x2' LED recessed luminaire with ...Watts system wattage. Housing shall be with pressure die cast aluminum alloy with corrosion proof resistant polyester power coated. Driver operates with voltage range from 100V to 270V 50/60 Hz with short circuit, overload & mis-wiring protection. Lumen Maintenance of 70% at 50000 Hrs. Injection moulded poly carbonate diffuser for better mechanical stability, light transmission & avoid pot hole effect. Junction temperature shall be 70 degree Celsius. Driver is on constant current driver @ 0.06A with PF 0.92 with line voltage @ 220-240V @ 50/60Hz, driver efficiency 85% & THD15%. LED Efficiency 130 lm/W at 1W & Fixture Efficiency 75lm/w with CRI 75 with injection moulded Polycarbonate lens with 80mm depth. 5 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' /1' X 4' 34 -36watt (Page No.35 / Item No.11.6.2 Electrical SR of 2022-23) | Nos | 5651.0 | 5651.0 | 6.0 | False | None | None | False | None | False | 33906.0 | 0 |
3740505 | 139464 | None | 11.8.4 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ...150.....W System Power consumption.LED StreetlightLED Streetlight 90 Watts (Page No.35 / Item No.11.8.4 Electrical SR of 2022-23) | Nos | 7777.0 | 7777.0 | 2.0 | False | None | None | False | None | False | 15554.0 | 0 |
3740506 | 139464 | None | 5.43.2 | Supply and Installation / Fixing / Provision of Pole box with HRC Fuse / MCB provision and suitable connector / terminal for 3 Ph/ 1 Ph connections with Loop-In & Loop- Out terminals for 10 Sqmm /25 Sqmm 3.5 C AI/Ar/Cu/Ar Cable and branch out 2.5 Sqmm 2 core AI/Cu PVC Insulated cable, enclosed in a Thermoplastic, Polystyrene enclosure, which should be shock proof, safe, IP65(Weather Proof), rust proof, dust proof, water proof having Internally Embedded Gasket with provision for cable entry through IP65 Thermoplastic, polyamide glands and/or grommets. (5.43) 260mm x 210mm x 116mm (Page No.16 / Item No.5.43.2 Electrical SR of 2022-23) | Nos | 2218.0 | 2218.0 | 4.0 | False | None | None | False | None | False | 8872.0 | 0 |
3740507 | 139464 | None | 13.2.3 | Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. (13.2) Using 40mm dia G.I.Pipe (Page No.45 / Item No.13.2.3 Electrical SR of 2022-23) | Nos | 119.0 | 119.0 | 88.0 | False | None | None | False | None | False | 10472.0 | 0 |
3740508 | 139464 | None | 13.7.1 | Fixing all types and all capacities of fluorescent/False ceiling/spot light /CFL/LED fittings indoor on the wall/ ceiling/ rafters/girders using 23/0.0076' twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall / ceiling /Rafter / Girders. (Page No.45 / Item No.13.7.1 Electrical SR of 2022-23) On wall / ceiling /Rafter / Girders. | Nos | 119.0 | 119.0 | 88.0 | False | None | None | False | None | False | 10472.0 | 0 |
3740509 | 139464 | None | 13.7.1 | Fixing all types and all capacities of fluorescent/False ceiling/spot light /CFL/LED fittings indoor on the wall/ ceiling/ rafters/girders using 23/0.0076' twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall / ceiling /Rafter / Girders. (Page No.45 / Item No.13.7.1 Electrical SR of 2022-23) Using necessary length of G.I.chain. (Item 13.7.2) | Nos | 253.0 | 253.0 | 12.0 | False | None | None | False | None | False | 3036.0 | 0 |
3740510 | 139464 | None | 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer.48" Sweep 5 Star (1200 mm) (Page No.23 / Item No.6.4.1 Electrical SR of 2022-23) | Nos | 2949.0 | 2949.0 | 20.0 | False | None | None | False | None | False | 58980.0 | 0 |
3740511 | 139464 | None | 6.2.1 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50HZ, AC Supply complete. 12" Sweep(300mm) (Page No.23 / Item No.6.2.1 Electrical SR of 2022-23) On wall / ceiling /Rafter / Girders. | Nos | 2997.0 | 2997.0 | 10.0 | False | None | None | False | None | False | 29970.0 | 0 |
3740512 | 139464 | None | 13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. (Page No.45 / Item No.13.1 Electrical SR of 2022-23) | Nos | 162.0 | 162.0 | 30.0 | False | None | None | False | None | False | 4860.0 | 0 |
3740513 | 139464 | None | 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colourign to match the existing wall or brackets, with bolts and nuts and a 5 ampsl,ceiling rose with sufficient length of 23/0.0076 inch PVC insulted twin core wire of approved make with wire mesh and wooden frame. (Page No.45 / Item No.13.13 Electrical SR of 2022-23) | Nos | 702.0 | 702.0 | 14.0 | False | None | None | False | None | False | 9828.0 | 0 |
3740514 | 139464 | None | 1.6.2 | Digging of Pit for providing GI Pipe type Earthing (Item No.1.6.2 Hard Soil). BESCOM SR 2022-23. | Nos | 2267.0 | 2267.0 | 4.0 | False | None | None | False | None | False | 9068.0 | 0 |
3740515 | 139464 | None | 54.01 | Item No. 54 : Grounding Material : Pipe Earthing : GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete. Minimum Weight of GI Pipe: 7.3 Kg (Item No. 54.01) Material Code : 281674. BESCOM SR 2022-23 | Nos | 770.0 | 770.0 | 4.0 | False | None | None | False | None | False | 3080.0 | 0 |
3740516 | 139464 | None | 54.02 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each. (Item No.54.02). Material Code : 600095. BESCOM SR 2022-23. | Nos | 660.0 | 660.0 | 9.0 | False | None | None | False | None | False | 5940.0 | 0 |
3740517 | 139464 | None | 54.03 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag. (Item No.54.03). Material Code : 607054. BESCOM SR 2022-23. | Nos | 303.0 | 303.0 | 8.0 | False | None | None | False | None | False | 2424.0 | 0 |
3740518 | 139464 | None | 6.3.10 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required 600x600x3mm Copper plate (Page No.40/Item No.6.3.10 Ele SR of 2019-20) | Nos | 6900.0 | 6900.0 | 2.0 | False | None | None | False | None | False | 13800.0 | 0 |
3740519 | 139464 | None | 5.42.2 | Fabricating supplying and mounting MS box made out SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc.16 SWG (Page No.15 / Item No.5.42.2 Electrical SR of 2022-23) | Sq CM | 0.35 | 0.35 | 100000.0 | False | None | None | False | None | False | 35000.0 | 0 |
3740520 | 139464 | None | 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. (Page No.14 / Item No.5.34 Electrical SR of 2022-23) | Nos | 505.0 | 505.0 | 3.0 | False | None | None | False | None | False | 1515.0 | 0 |
3740521 | 139464 | None | 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. (Page No.14 / Item No.5.33 Electrical SR of 2022-23) | Nos | 8370.0 | 8370.0 | 1.0 | False | None | None | False | None | False | 8370.0 | 0 |
3740522 | 139464 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C. (Page No.14 / Item No.5.38 Electrical SR of 2022-23) | Nos | 464.0 | 464.0 | 3.0 | False | None | None | False | None | False | 1392.0 | 0 |
3740523 | 139464 | None | 5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. (Page No.14 / Item No.5.21 Electrical SR of 2022-23) | Nos | 8310.0 | 8310.0 | 1.0 | False | None | None | False | None | False | 8310.0 | 0 |
3740524 | 139464 | None | 5.40.2 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250Amps 4x30x10mm Aluminum Strips (Page No.15 / Item No.5.40.2 Electrical SR of 2022-23) | Nos | 3078.0 | 3078.0 | 2.0 | False | None | None | False | None | False | 6156.0 | 0 |
3740525 | 139464 | None | 5.12.2 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. 100Amps (Page No.12 / Item No.5.12.2 Electrical SR of 2022-23) | Nos | 7971.0 | 7971.0 | 1.0 | False | None | None | False | None | False | 7971.0 | 0 |
3740526 | 139464 | None | 5.17.7 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. FOUR POLE.100 Amps 35kA. (Page No.12/ Item No.5.14.7 Electrical SR of 2022-23) | No | 8265.0 | 8265.0 | 1.0 | False | None | None | False | None | False | 8265.0 | 0 |
3740527 | 139464 | None | 5.41.2 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm (Page No.15 / Item No.5.41.2 Electrical SR of 2022-23) | Mtr | 356.0 | 356.0 | 10.0 | False | None | None | False | None | False | 3560.0 | 0 |
3740528 | 139464 | None | 32.09 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 16 Sqmm, 3.5 Core, (14 GI Strips - 4 x 0.8 mm) Item No 32.09,Material Code :287059, Bescom SR 2021-22 | Km | 183442.0 | 183442.0 | 0.12 | False | None | None | False | None | False | 22013.04 | 0 |
3740529 | 139464 | None | 32.09 | 35 Sqmm, 3.5 Core, (14 GI Strips - 4 x 0.8 mm) Item No 32.09,Material Code :287059, Bescom SR 2021-22 | Km | 208670.0 | 208670.0 | 0.085 | False | None | None | False | None | False | 17736.95 | 0 |
3740530 | 139464 | None | 31.05 | Labour charges for Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. ( Item No.31.05) Bescom SR 2021-22. 230 2.5 to 25 Sqmm | Km | 16159.0 | 16159.0 | 0.12 | False | None | None | False | None | False | 1939.08 | 0 |
3740531 | 139464 | None | 31.05 | Labour charges for Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. ( Item No.31.05) Bescom SR 2021-22. 230 25 sqmm to 75 sqmm | Km | 23647.0 | 23647.0 | 0.085 | False | None | None | False | None | False | 2009.995 | 0 |
3740532 | 139464 | None | 001 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Hard Soil | Cum | 389.0 | 389.0 | 42.0 | False | None | None | False | None | False | 16338.0 | 0 |
3740533 | 139464 | None | 001 | LAN NET-WORKING,AIR CONDITIONING AND UPS SYSTEM Conceiled Conduit System upplying heavy gauge PVC conduit pipe dia confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick. | Mtr | 70.0 | 70.0 | 1150.0 | False | None | None | False | None | False | 80500.0 | 0 |
3740534 | 139464 | None | 001 | Supplying heavy gauge PVC Conduit Pipe dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick | Mtr | 80.0 | 80.0 | 280.0 | False | None | None | False | None | False | 22400.0 | 0 |
3740535 | 139464 | None | 001 | Supplying and drawing UTP-CAT 6E LAN cable.(8.1) | Mtr | 34.0 | 34.0 | 1290.0 | False | None | None | False | None | False | 43860.0 | 0 |
3740536 | 139464 | None | 001 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.5Pair | Mtr | 58.0 | 58.0 | 500.0 | False | None | None | False | None | False | 29000.0 | 0 |
3740537 | 139464 | None | 001 | Supplying & fixing of I/O socket with back box .(8.10) Single I/O | Each | 405.0 | 405.0 | 30.0 | False | None | None | False | None | False | 12150.0 | 0 |
3740538 | 139464 | None | 001 | Supplying & fixing of I/O socket with back box .(8.10) Double I/O | Each | 727.0 | 727.0 | 14.0 | False | None | None | False | None | False | 10178.0 | 0 |
3740539 | 139464 | None | 001 | Supplying & Fixing of switch mounting rack with power manager & Cable manager. .(8.4) 9U with 450mm depth | Each | 7546.0 | 7546.0 | 2.0 | False | None | None | False | None | False | 15092.0 | 0 |
3740540 | 139464 | None | 001 | Supplying fixing of Network Switches .(8.9) 8 port 10/100/1000 Switch | Each | 3437.0 | 3437.0 | 4.0 | False | None | None | False | None | False | 13748.0 | 0 |
3740541 | 139464 | None | 001 | Supplying fixing of Network Switches .(8.9) 24 Port Gigabyte (manageable) | Each | 46053.0 | 46053.0 | 2.0 | False | None | None | False | None | False | 92106.0 | 0 |
3740542 | 139464 | None | 8.12 | Supplying & Fixing of Patch panel for LAN cabling (8.12) 24 Port 10/100 patch panel 24 Port Gigabyte (manageable) | Each | 4258.0 | 4258.0 | 2.0 | False | None | None | False | None | False | 8516.0 | 0 |
3740543 | 139464 | None | 8.11.1 | Supplying & Fixing of ... Mtrs Cat 6 Patch Cable (8.11) 1 mtr (8.11.1) | Mtr | 190.0 | 190.0 | 19.0 | False | None | None | False | None | False | 3610.0 | 0 |
3740544 | 139464 | None | 8.11.2 | Supplying & Fixing of ... Mtrs Cat 6 Patch Cable (8.11) 2 mtr (8.11.2) | Mtr | 286.0 | 286.0 | 18.0 | False | None | None | False | None | False | 5148.0 | 0 |
3740545 | 139464 | None | 001 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete.5 KVA ON LINE UPS | Each | 79177.0 | 79177.0 | 2.0 | False | None | None | False | None | False | 158354.0 | 0 |
3740546 | 139464 | None | 001 | Supplying, installation, testing & commissioning of 12Volts ..AH batteries in poly propylene container for . Low maintenance batteries, plate type.120 AH capacity. | Each | 22135.0 | 22135.0 | 12.0 | False | None | None | False | None | False | 265620.0 | 0 |
3740547 | 139464 | None | 001 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50x50x6mm. | Each | 356.0 | 356.0 | 28.0 | False | None | None | False | None | False | 9968.0 | 0 |
3740548 | 139464 | None | 001 | Wiring for lighting / power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system wiring with specified IS-694:confirming to latest amendment 10 mm2 | Mtr | 157.0 | 157.0 | 48.0 | False | None | None | False | None | False | 7536.0 | 0 |
3740549 | 139464 | None | 001 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. Group "A" 1.5 sqmm. 1.5 sqmm. | Mtr | 26.0 | 26.0 | 400.0 | False | None | None | False | None | False | 10400.0 | 0 |
3740550 | 139464 | None | 002 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. Group "A" 4 sqmm. | Mtr | 59.0 | 59.0 | 800.0 | False | None | None | False | None | False | 47200.0 | 0 |
3740551 | 139464 | None | 6.8.6 | Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. (47/6.8) 2 ton capacity (Page No.47/Item Noo.6.8.6) | Each | 78872.0 | 78872.0 | 2.0 | False | None | None | False | None | False | 157744.0 | 0 |
3740552 | 139464 | None | 6.12 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 ton split/cassette type A/C. (Page No.48/Item No.6.12) | Each | 4981.0 | 4981.0 | 2.0 | False | None | None | False | None | False | 9962.0 | 0 |
3740553 | 139464 | None | 6.13 | Supplying and installation of insulated refrigerant copper tubing of 5/8 and 3/8 with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube. (48/6.13) Split | Each | 1631.0 | 1631.0 | 20.0 | False | None | None | False | None | False | 32620.0 | 0 |
3740554 | 139464 | None | 6.19 | Supplying & filling refrigerant (F-22/F/12) for air conditioning equipments. Which includes the labour & Nitrogen gas for pressure and leak testing. (49/6.19 | Each | 590.0 | 590.0 | 6.0 | False | None | None | False | None | False | 3540.0 | 0 |
3740555 | 139464 | None | 9.1.3 | Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. (9.1) 5KVA Capacity (9.1.3) | Each | 4929.0 | 4929.0 | 2.0 | False | None | None | False | None | False | 9858.0 | 0 |
3740556 | 139464 | None | 6.22 | Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries. (49/6.22) | Each | 4576.0 | 4576.0 | 2.0 | False | None | None | False | None | False | 9152.0 | 0 |