1724314227000 | 0 | None | None | Other Works | High mast light installation near Rural Police Station Bantwal Kasba and Construction of drain on Mahammadali road | 404539.92 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3834676 | 146245 | None | code1 | Fabrication, Supplying, Erection, Testing and Commissioning of...... ms long Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mas shall be Galvanized in single Hot-dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data. 12 m/12.5 m - Top 100 mm and Bottom 310 mm dia | Each | 116177.0 | 116177.0 | 1.0 | False | None | None | False | None | False | 116177.0 | 0 | 3834677 | 146245 | None | code2 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for outdoor luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Double Arm Bracket with 2000 mm Standard 40/50 mm dia | Each | 3524.0 | 3524.0 | 1.0 | False | None | None | False | None | False | 3524.0 | 0 | 3834678 | 146245 | None | code3 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. | Each | 1103.0 | 1103.0 | 1.0 | False | None | None | False | None | False | 1103.0 | 0 | 3834679 | 146245 | None | code4 | Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers | Each | 4352.0 | 4352.0 | 1.0 | False | None | None | False | None | False | 4352.0 | 0 | 3834680 | 146245 | None | code5 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ LED Floodlight 150W | No | 11128.0 | 11128.0 | 6.0 | False | None | None | False | None | False | 66768.0 | 0 | 3834681 | 146245 | None | code6 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:2010 3C x 2.5 mm2 | Mtr | 130.0 | 130.0 | 18.0 | False | None | None | False | None | False | 2340.0 | 0 | 3834682 | 146245 | None | code7 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr, Width and Depth upto I Mtr including trial pis, depositing on bank upto a lead 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and sign Boards at every 100 Mtr wherever necessary as directed. In Hard Soil Bescom : Labour Rate For Common SR:2021-22 | cm | 389.0 | 389.0 | 35.0 | False | None | None | False | None | False | 13615.0 | 0 | 3834683 | 146245 | None | code8 | Supply and Installation / Fixing / Provision of Pole box with HRC Fuse / MCB provision and suitable connector / terminal for 3 Ph/ 1 Ph connections with Loop-In & Loop- Out terminals for 10 mm2 /25 mm2 3.5 C AI/Ar/Cu/Ar Cable and branch out 2.5 mm2 2 core AI/Cu PVC Insulated cable, enclosed in a Thermoplastic, Polystyrene enclosure, which should be shock proof, safe, IP65(Weather Proof), rust proof, dust proof, water proof having Internally Embedded Gasket with provision for cable entry through IP65 Thermoplastic, polyamide glands and/or grommets. 260 mm x 210 mm x 116 mm | Each | 2218.0 | 2218.0 | 1.0 | False | None | None | False | None | False | 2218.0 | 0 | 3834684 | 146245 | None | code9 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 189.0 | 189.0 | 8.0 | False | None | None | False | None | False | 1512.0 | 0 | 3834685 | 146245 | None | code10 | PVC Pipe -75mm Dia | Mtr | 160.0 | 160.0 | 65.0 | False | None | None | False | None | False | 10400.0 | 0 | 3834686 | 146245 | None | code11 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS-694:2010 4C x 6 mm2 | Mtr | 297.0 | 297.0 | 35.0 | False | None | None | False | None | False | 10395.0 | 0 | 3834687 | 146245 | None | code12 | LT AC 3 Phase 4 Wire, 10-60 Amps smart Energy Meter, Class 1.0 Accuracy with RF communication Module. | No | 3200.0 | 3200.0 | 1.0 | False | None | None | False | None | False | 3200.0 | 0 | 3834688 | 146245 | None | code13 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility 600 mm x 600 mm x 170 mm | Each | 13047.0 | 13047.0 | 1.0 | False | None | None | False | None | False | 13047.0 | 0 | 3834689 | 146245 | None | code14 | KSRB 2-2.2: Earthwork excavation by manual means for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in hard soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead up to 50 m. after breaking of clods complete as per specifications. Specification. No. KBS 2.1(b) / 2.3.5 1.5X1.5X1.5 | Cum | 448.0 | 448.0 | 3.37 | False | None | None | False | None | False | 1509.76 | 0 | 3834690 | 146245 | None | code15 | KSRB 4-1.2 : Providing and laying in position plain cement concrete of Mix 1:3:6 with OPC @ 220kgs, with 40mm and down size graded granite metal coarse aggregates @0.892cum and fine aggregates @ 0.465cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 ems. Thick, well compacted, in foundation including cost of all materials, labour, HOM curing complete as per specifications. Specification No. KBS 4.1, 4.2 1.5X1.5X0.15 | Cum | 3633.8 | 3633.8 | 4.2 | False | None | None | False | None | False | 15261.96 | 0 | 3834691 | 146245 | None | code16 | KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and I or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM complete as per specifications. Specification No. KBS 4.6.3 | Tonne | 70782.0 | 70782.0 | 0.19 | False | None | None | False | None | False | 13448.58 | 0 | 3834692 | 146245 | None | code17 | KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design Mix M20 with OPC @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with super plasticizers @31ts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 ems thick, vibrated for all works in ground floor level for roof slabs, staircase, lintels, and beams retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 | Cum | 6272.0 | 6272.0 | 2.0 | False | None | None | False | None | False | 12544.0 | 0 | 3834693 | 146245 | None | code18 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7664.16 | 7664.16 | 5.74 | False | None | None | False | None | False | 43992.2784 | 0 | 3834694 | 146245 | None | code19 | TMT Steel : Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications. | Quintal | 10019.18 | 10019.18 | 6.9 | False | None | None | False | None | False | 69132.342 | 0 |
|