| 3804245 | 144471 | None | Item No.1.14.1 Page No.8 Vol.1 | KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. | Cum | 114.24 | 114.24 | 253.904 | False | None | None | False | None | False | 29005.99296 | 0 |
| 3804246 | 144471 | None | Item No. 2.1.2 Page No. 15 Vol.1 | KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 M5 Using 40 mm nominal size graded crushed coarse aggregates The cost of steel reinforcement and formwork shall be paid separately. | Cum | 6343.68 | 6343.68 | 200.33 | False | None | None | False | None | False | 1270829.4144 | 0 |
| 3804247 | 144471 | None | Item No. 2.3.2 Page No. 16 Vol.1 page No.115 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7776.0 | 7776.0 | 307.89 | False | None | None | False | None | False | 2394152.64 | 0 |
| 3804248 | 144471 | None | Item No. 2.3.2 Page No. 16 Vol.1 page No.115 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 | Cum | 11793.6 | 11793.6 | 31.72 | False | None | None | False | None | False | 374092.992 | 0 |
| 3804249 | 144471 | None | Item No.2.2.3 VOL 1 | KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement & formwork to be paid separately. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10264.32 | 10264.32 | 20.13 | False | None | None | False | None | False | 206620.7616 | 0 |
| 3804250 | 144471 | None | Item No. 2.11 Page No. 18 Vol | KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / softannealed steel wire and other ancilary operations complete as per drawing andtechnical specification. | MT | 100191.84 | 100191.84 | 21.7629 | False | None | None | False | None | False | 2180464.994736 | 0 |
| 3804251 | 144471 | None | Item No. 5.56 VOL 2 | KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 1 cement : 6 coarse sand. | Cum | 7155.68 | 7155.68 | 91.28 | False | None | None | False | None | False | 653170.4704 | 0 |
| 3804252 | 144471 | None | Item No. 1.8 Page No. 7 Vol.1 | KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work | Cum | 474.0 | 474.0 | 1561.16 | False | None | None | False | None | False | 739989.84 | 0 |
| 3804253 | 144471 | None | Item No. 6.33 Page No. 17 Vol.2 | KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1378.72 | 1378.72 | 428.76 | False | None | None | False | None | False | 591139.9872 | 0 |
| 3804254 | 144471 | None | Item No. 8.3.1, Page No. 41, Vol.2 | KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 330.4 | 330.4 | 892.27 | False | None | None | False | None | False | 294806.008 | 0 |
| 3804255 | 144471 | None | Item No. 11.2, Page No. 77, Vol.2 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. | Kg | 126.56 | 126.56 | 78600.0 | False | None | None | False | None | False | 9947616.0 | 0 |
| 3804256 | 144471 | None | Item No.1 | Turbo vents | No | 5000.0 | 5000.0 | 12.0 | False | None | None | False | None | False | 60000.0 | 0 |
| 3804257 | 144471 | None | Item No. 7.38, Page No. 26, Vol.2 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 585.04 | 585.04 | 3159.55 | False | None | None | False | None | False | 1848463.132 | 0 |
| 3804258 | 144471 | None | Item No. 8.51, Page No. 50, Vol.2 | KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 112.0 | 112.0 | 892.27 | False | None | None | False | None | False | 99934.24 | 0 |
| 3804259 | 144471 | None | Item No. 8.54.1, Page No. 50, Vol.2 | KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge. | No | 81.76 | 81.76 | 432.91 | False | None | None | False | None | False | 35394.7216 | 0 |
| 3804260 | 144471 | None | Item No. 8.54.1, Page No. 50, Vol.2 | KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC Volatile Organic Compound content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge. | No | 81.76 | 81.76 | 395.87 | False | None | None | False | None | False | 32366.3312 | 0 |
| 3804261 | 144471 | None | Item No. 11.6.1, Page No. 76, Vol.2 | KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 2948.96 | 2948.96 | 57.38 | False | None | None | False | None | False | 169211.3248 | 0 |
| 3804262 | 144471 | None | Item No. 11.8.4, Page No. 77, Vol.2 | KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | No | 27648.32 | 27648.32 | 3.0 | False | None | None | False | None | False | 82944.96 | 0 |
| 3804263 | 144471 | None | Item No. 11.35.1.1, Page No. 87, Vol.2 | KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. | Kg | 506.24 | 506.24 | 690.0 | False | None | None | False | None | False | 349305.6 | 0 |
| 3804264 | 144471 | None | SI NO. 11.9.3 P.No 46 | Supply of LED floodlight luminaire with pressure die castaluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonateclear glass material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70 CCT 5500K IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08 Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltageOverloadshort circuit miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322IEC 60598, LM 79 & LM 80 Adherence with RoHS UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 120W SystemPower consumption. LED Efficiency 1301mw nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL CPRI any Government certified agency & Design & Development facility certified by ISO 90012008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should | No | 10757.0 | 10757.0 | 21.0 | False | None | None | False | None | False | 225897.0 | 0 |
| 3804265 | 144471 | None | SI NO. 5.19.15 P.No 18 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. | Each | 10395.0 | 10395.0 | 10.0 | False | None | None | False | None | False | 103950.0 | 0 |
| 3804266 | 144471 | None | SI NO. 5.29 P.No 19 P.W.D (EL) SR 2023-24 | Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter | Each | 1425.0 | 1425.0 | 10.0 | False | None | None | False | None | False | 14250.0 | 0 |
| 3804267 | 144471 | None | SI NO. 5.33 P.No 19 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accurac | Each | 9315.0 | 9315.0 | 2.0 | False | None | None | False | None | False | 18630.0 | 0 |
| 3804268 | 144471 | None | P N0 56 SL NO 13.5 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 162.0 | 162.0 | 21.0 | False | None | None | False | None | False | 3402.0 | 0 |
| 3804269 | 144471 | None | Item No.5.18.6 P.No 17 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. | Each | 1102.0 | 1102.0 | 20.0 | False | None | None | False | None | False | 22040.0 | 0 |
| 3804270 | 144471 | None | P.No 2 SL NO 1.1.2 | Supplying heavy gauge PVC conduit pipe 25.dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. | Each | 81.0 | 81.0 | 300.0 | False | None | None | False | None | False | 24300.0 | 0 |
| 3804271 | 144471 | None | P.No 2 SL NO 1.3.3 | Supplying heavy gauge PVC conduit pipe 32MM .dia 2.5 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. | Each | 106.0 | 106.0 | 250.0 | False | None | None | False | None | False | 26500.0 | 0 |
| 3804272 | 144471 | None | P.No 1 SL NO 1.1.4 | Supplying heavy gauge PVC conduit pipe 40MM .dia 2.5 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws | Each | 149.0 | 149.0 | 300.0 | False | None | None | False | None | False | 44700.0 | 0 |
| 3804273 | 144471 | None | P.No 10 sl no 5.7.4 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. | m | 691.0 | 691.0 | 10.0 | False | None | None | False | None | False | 6910.0 | 0 |
| 3804274 | 144471 | None | P.No 5 SL NO 2.2.5 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. | Point | 989.0 | 989.0 | 50.0 | False | None | None | False | None | False | 49450.0 | 0 |
| 3804275 | 144471 | None | P.No 5 SL NO 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.. | m | 42.0 | 42.0 | 1000.0 | False | None | None | False | None | False | 42000.0 | 0 |
| 3804276 | 144471 | None | P.No 3 SL NO 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.. | m | 26.0 | 26.0 | 1000.0 | False | None | None | False | None | False | 26000.0 | 0 |
| 3804277 | 144471 | None | P.No 5 SL NO 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.. | m | 63.0 | 63.0 | 600.0 | False | None | None | False | None | False | 37800.0 | 0 |
| 3804278 | 144471 | None | P.No 6 SL NO 2.3.6 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.. | m | 167.0 | 167.0 | 600.0 | False | None | None | False | None | False | 100200.0 | 0 |
| 3804279 | 144471 | None | P.No 6 SL NO 2.3.6 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.. | m | 318.0 | 318.0 | 300.0 | False | None | None | False | None | False | 95400.0 | 0 |
| 3804280 | 144471 | None | P.No 19 sl no 5.35 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. | Each | 5705.0 | 5705.0 | 3.0 | False | None | None | False | None | False | 17115.0 | 0 |
| 3804281 | 144471 | None | P.No 19 sl no 5.35 | Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 V 3 phase and wired after fixing to the existing wooden board for mot | Each | 7455.0 | 7455.0 | 9.0 | False | None | None | False | None | False | 67095.0 | 0 |
| 3804282 | 144471 | None | P.No 20 sl no 5.42.1 | Fabricating supplying and mounting MS box made out 14SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. | Sq CM | 0.5 | 0.5 | 150000.0 | False | None | None | False | None | False | 75000.0 | 0 |
| 3804283 | 144471 | None | P.No 17 SL NO 5.15.13 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. | m | 22530.0 | 22530.0 | 2.0 | False | None | None | False | None | False | 45060.0 | 0 |
| 3804284 | 144471 | None | P.No 17 SL NO 5.16 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT | Each | 1703.0 | 1703.0 | 8.0 | False | None | None | False | None | False | 13624.0 | 0 |
| 3804285 | 144471 | None | P.No 20 SL NO 5.40.2 | Supplying .250 A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete | m | 3435.0 | 3435.0 | 10.0 | False | None | None | False | None | False | 34350.0 | 0 |
| 3804286 | 144471 | None | P.No 55 sl no 12.60.3 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cutouts & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm | Kit | 8494.0 | 8494.0 | 10.0 | False | None | None | False | None | False | 84940.0 | 0 |
| 3804287 | 144471 | None | P.No 54 sl no 12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Each | 4256.0 | 4256.0 | 10.0 | False | None | None | False | None | False | 42560.0 | 0 |
| 3804288 | 144471 | None | SI NO. 6.3.7 P.No 40 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. | m | 1643.0 | 1643.0 | 80.0 | False | None | None | False | None | False | 131440.0 | 0 |
| 3804289 | 144471 | None | P.No 18 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. Item No.5.18.9 | Each | 3088.0 | 3088.0 | 20.0 | False | None | None | False | None | False | 61760.0 | 0 |
| 3804290 | 144471 | None | P.No 16 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. Item No.5.13.3 | Each | 5950.0 | 5950.0 | 3.0 | False | None | None | False | None | False | 17850.0 | 0 |
| 3804291 | 144471 | None | SI NO. 203 itam no 32.07 P.No 13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 | m | 139.54 | 139.54 | 250.0 | False | None | None | False | None | False | 34885.0 | 0 |
| 3804292 | 144471 | None | P.No 30 | Supplyingof Ceiling Fan with Capacitor rating As perguideline of BEE 5 star rating and IS:374/79 and alsocomplywithIS:1709/1984withlatestamendment,Ratedvoltage220V/50Hz,Rated power input 48 W +/- 10 %,RatedcurrentAsperIS:374/79,Ratedpowerfactor0.9lagging(min),Ratedspeed350 +/- 10% RPM, Rated airdelivery210+/-10%CubicMeterMinimum, Rated servicevalue 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thickAluminiumAlloy sheet,Class B motor insulation, Bearing Twoball bearings, Top 6202, Bottom 6201, as per IS specification,Motor winding. Temp rise Shall not exceed 75 deg C over andambientof 400C byresistancemethodat 245V, Insulationresistance Shall not be less than Two Mega Ohms (2MOhms),LeakagecurrentShouldnotexceed210Micro Powerinput,W¤t,AirDelivery&FanSpeedasperIS:374/1979withlatestamendment,2yearmanufacturerWarranty.SI NO. 6.4.1 | Each | 2677.0 | 2677.0 | 10.0 | False | None | None | False | None | False | 26770.0 | 0 |
| 3804293 | 144471 | None | SI NO. 203 itam no 32.07 P.No 13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 | m | 141.84 | 141.84 | 300.0 | False | None | None | False | None | False | 42552.0 | 0 |
| 3804294 | 144471 | None | SI NO. 5.33 P.No 19 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Each | 9315.0 | 9315.0 | 1.0 | False | None | None | False | None | False | 9315.0 | 0 |
| 3804295 | 144471 | None | Item No.5.37 P.No 19 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like
induction motor. | Each | 480.0 | 480.0 | 30.0 | False | None | None | False | None | False | 14400.0 | 0 |
| 3804296 | 144471 | None | Item No.5.37 P.No 19 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz12/24V D.C. | Each | 480.0 | 480.0 | 20.0 | False | None | None | False | None | False | 9600.0 | 0 |
| 3804297 | 144471 | None | Item No.5.39 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs P.G.NO 19 SL.NO | Each | 21640.0 | 21640.0 | 2.0 | False | None | None | False | None | False | 43280.0 | 0 |
| 3804298 | 144471 | None | Item No.2.5.8 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010P.G.NO 6 SL.NO . | m | 113.0 | 113.0 | 150.0 | False | None | None | False | None | False | 16950.0 | 0 |
| 3804299 | 144471 | None | SL.NO2.5.23 .Item No.2.5.8 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010P.G.NO 7 | m | 328.0 | 328.0 | 250.0 | False | None | None | False | None | False | 82000.0 | 0 |
| 3804300 | 144471 | None | P.No 19 | Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer No.5.36 | Each | 840.0 | 840.0 | 6.0 | False | None | None | False | None | False | 5040.0 | 0 |
| 3804301 | 144471 | None | P.No 8 SL NO 3..4.8 | Supplying and fixing surface/flush mounting unbreakable PVCmodular box suitable for mounting modular switch plates withdue groove cutting in Brick/C.C wall, including necessary rawlplugs,Machine/NFscrewsetc.,complete. | m | 405.0 | 405.0 | 10.0 | False | None | None | False | None | False | 4050.0 | 0 |
| 3804302 | 144471 | None | P.No 5 SL NO 3.5.8 | Supplying and fixing superior quality modular switch mountingpolycarbonate plate with necessary supporting back plate withrequirednos.ofmachinescrews,boltsnutsetc.,complete on theexistingmetal/PVCbox. | Each | 457.0 | 457.0 | 10.0 | False | None | None | False | None | False | 4570.0 | 0 |
| 3804303 | 144471 | None | P.No 8 sl no 3.6.3 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexistingmodularswitchplateasperIS3854andIS1293. | Each | 171.0 | 171.0 | 20.0 | False | None | None | False | None | False | 3420.0 | 0 |
| 3804304 | 144471 | None | P.No 8 sl no 3.6.1 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexistingmodularswitchplateasperIS3854andIS1293. | Each | 102.0 | 102.0 | 50.0 | False | None | None | False | None | False | 5100.0 | 0 |
| 3804305 | 144471 | None | SI NO. 6..1 P.No 30 | Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. | Each | 2492.0 | 2492.0 | 10.0 | False | None | None | False | None | False | 24920.0 | 0 |
| 3804306 | 144471 | None | P.G.NO 10 SL.NO . Item No.3.14 7 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. | No | 74.0 | 74.0 | 20.0 | False | None | None | False | None | False | 1480.0 | 0 |
| 3804307 | 144471 | None | Item No.3.14 6 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. P.G.NO 10 SL.NO | No | 71.0 | 71.0 | 20.0 | False | None | None | False | None | False | 1420.0 | 0 |
| 3804308 | 144471 | None | No.11.3.2 P.No 34 | Supplyingof 4 feet PVCBattenwithintegratedLEDtube 20 22W with high quality diffuser with Life of 25000 burninghours 70 lumen maintenance with CRI 80. PowerInput 220-240V 50 60Hz Power factor 0.9 along with CEapproved.2 years Warranty against any manufacturing defectworkingunderstandardelectricalcondition | Each | 690.0 | 690.0 | 30.0 | False | None | None | False | None | False | 20700.0 | 0 |
| 3804309 | 144471 | None | P.No 47 | Supplying & fixing of retrofit type LED bulb 12 W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K CRI 70 efficacy 80 lumen per W life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5 of lamp Wage short circuit open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABLCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition | Each | 269.0 | 269.0 | 15.0 | False | None | None | False | None | False | 4035.0 | 0 |
| 3804310 | 144471 | None | 1.1 | Supplying & fixing 20 inch Stainless Steel Electric, Automatic Turbo Roof Exhaust Fans, For Rooftop 220V, 50Hz Frequency, 184,000 Cfh (Cu Ft Per hour) Exhaust Capacity as per direction of site engineer. | Each | 20000.0 | 20000.0 | 10.0 | False | None | None | False | None | False | 200000.0 | 0 |