createdTs None version None createdDate None modifiedDate None noticeInvitingTenderDTO
createdTs 1723895369990 version 2 createdDate None modifiedDate None tenderType RFQ evaluationType TWO_COVER evaluationTypeText Two Cover invitingStrategy OPEN invitingStrategyText Open taxType INCLUSIVE_TAX tenderFee 500.00 emd 17950.00 bidValueType ITEM_WISE bidValueTypeText Item wise tenderReceiptClose 30-08-2024 16:30:11 tenderQueryClose 29-08-2024 16:30:00 technicalBidOpen 01-09-2024 10:30:23 publishedDate 22-08-2024 22:34:11 publishedByPost TP_CO_LKPR publishedByUser KPE16950 - JYOTI V UPPAR bidValidityPeriod 90 noOfCalls 1 preBidMeetingDate None preBidMeetingYn False preQualificationBidOpen None denominationType RUPEES denominationTypeText Rupees retenderedYn None percentageRateTypeText None contactPerson PATIL splitEmdRequiredYn False emdBankGuarantee None emdCash None bgValidityPeriod None hideWeightage None multipleCurrencySelectionAllowedYn False isTechWeightageAllowed None highestBidderSelection False isVariableEmdAllowed None qcbsTenderYn None itemwiseEmdRequiredYn None sampleSubmissionDate None officeNumber 08350200201 mobileNumber None tenderSupplierList None tenderSchedule
createdTs 1723895370019 version 5 createdDate None modifiedDate None tenderNumber DMA/2024-25/BD/WORK_INDENT23811 title CONSTRUCTION OF TOILET BLOCKS AT SWM SITE description CONSTRUCTION OF TOILET BLOCKS AT SWM SITE category WORKS categoryText Works ecv 718000.00 deptName Directorate of Municipal Administration status PUBLISHED statusText Published remarks None csrValue None ecvtenderYn True location 2229 locationName DMA Town Panchayat Lokapur provisionalAmount 718000.0 groupOverheadTotal 113030.43 fileNumber SBMSSWM/SanitaryLandfill/BLD/LKP/05 tenderSubEstimateList
createdTs version createdDate modifiedDate workCategoryName subEstimateName estimateTotal itemList 1723895370000 0 None None Buildings CONSTRUCTION OF TOILET BLOCKS AT SWM SITE 135316.0
id tenderSubEstimateId categoryName itemCode description uomName baseRate finalRate quantity modifyQuantityYn minQuantity maxQuantity buyBackYn buyBackValue hideYn netAmount taxCount 3798202 144047 None code01 Open Conduit System : Supplying heavy gauge PVC Conduit pipe diamm thick confirming to IS 2509 with suitable size bends, junctin boxes adhesive paste etc., and fixing using inverted wood plug n case of RCC wall / stone structure or raw /plug in case of brick walls and cement plastering the damged portion usign heavy gauge gaddles at an intervals of 700mm usgn NF screws. Item No.1.2 Part 1 (Open Conduit system) 1920mm dia 2mm thick ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Mtr 68.0 68.0 20.0 False None None False None False 1360.0 0 3798203 144047 None code02 25mm dia 2mm thick ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Mtr 80.0 80.0 20.0 False None None False None False 1600.0 0 3798204 144047 None code03 Concealed conduit sytem : Supplying heavy guage PVC conduit pipe mmdiamm thick conirming to IS 2509 with suitable size bends metal / PVC junction boxes adhesive paste etc, and running before concreting the slab, the conduit should be tied to the reinforcement rods by using bending wires and unused ways of junction boxes and pipes ends should be covered usign PVC end enclosures, run with 18SWG GI fish wire wherever necessary Item No.1.2.1 1.2.2 1.2.3, 1.2.4 Page No.1 19/20mm dia 2mm thick ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Mtr 61.0 61.0 100.0 False None None False None False 6100.0 0 3798205 144047 None code04 Supplyin heavy guage PVC conduit Pipediamm thick with suitable size bends, metal junction boxes, adhesive paste etc, by groove cuttin in the wall and fixing by bracing U or J hook and cement plastering up to the wall surface and run with 18 SWG G.I. fish wire run throughout the conduit pipe wherever necessary. Item No.1.3.1, 1.3.2 P.No.1 2021-21 Electrical SR 19/20mm dia 2mm thick ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Mtr 75.0 75.0 250.0 False None None False None False 18750.0 0 3798206 144047 None code05 25mm dia 2mm thick Supplyin heavy guage PVC conduit Pipediamm thick with suitable size bends, metal junction boxes, adhesive paste etc, by groove cuttin in the wall and fixing by bracing U or J hook and cement plastering up to the wall surface and run with 18 SWG G.I. fish wire run throughout the conduit pipe wherever necessary. Item No.1.3.1, 1.3.2 P.No.1 2021-21 Electrical SR 19/20mm dia 2mm thick ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Nos. 80.0 80.0 240.0 False None None False None False 19200.0 0 3798207 144047 None code06 Supplyig and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable / conduit entry as required with one coat of primer of approved make etc., Item No.1.4(1.4.5) Page No.1 SR 2021-22 100x75x65mm ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Nos. 112.0 112.0 12.0 False None None False None False 1344.0 0 3798208 144047 None code07 200x90x65mm ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Nos. 169.0 169.0 8.0 False None None False None False 1352.0 0 3798209 144047 None code08 up to 50mm conduit in Brick wall Extra for Groove cutting in Brick wall / C.C. floor to the suitable depth for conceling of conduit / GI pipe and plasteirng finishing up to wall surface complete Item 1.7. ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Mtr 26.0 26.0 35.0 False None None False None False 910.0 0 3798210 144047 None code09 up to 50mm conduit in C.C.floor ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Mtr 62.0 62.0 25.0 False None None False None False 1550.0 0 3798211 144047 None code10 Supplyign PVC G.I. Flexible conduit pipe mmdia fixing on surace over inverted tappered wooden plugs or phill plug or rawal plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screwes and on either end of the pipe terminated completely. No.2 SR 202122 Electrical SR120mm ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Mtr 25.0 25.0 10.0 False None None False None False 250.0 0 3798212 144047 None code11 1.9.2 25mm Supplyign PVC /G.I. Flexible conduit pipe mmdia fixing on surace over inverted tappered wooden plugs or phill plug or rawal plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screwes and on either end of the pipe terminated completely. Item No. 1.9, 1.9.1, 1.9.2 Page No.2 SR 2021-22 Electrical SR ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Mtr 31.0 31.0 10.0 False None None False None False 310.0 0 3798213 144047 None code12 Point wiring using copper wire with switch supplying and wiring adopting loop system in existing PVC conduit / casing capping using 2x1.5mm2(phase x Neutral) x 1x1.0mm2(earthwire) FRLS multi strand PVC insulated copper wire confirmign to IS 694 and latest amendments) with a 6A flush type 5P control swithc shall be fixed on the existing plastic sheet / gang box the other end of the wires shall be terminated with sufficient loose length in a wood / PVC round block complete for each outer. Short point upto 3m from tapping point to ut let via sevi ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No 276.0 276.0 11.0 False None None False None False 3036.0 0 3798214 144047 None code13 Wiring for lighting / powr circuit using one of FRLS PVC insulated 1100 V grade multi strand copper wire with low conductor resistance singe core in open or concealed system of wiring with specified IS 694 confirmign to latest amendments. Item No.2.3 Page No.3 SR 2021-22 Item No. 2.3.2 1.5mm2 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Nos. 26.0 26.0 75.0 False None None False None False 1950.0 0 3798215 144047 None code14 2.3.2 2.5mm2 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Nos. 40.0 40.0 50.0 False None None False None False 2000.0 0 3798216 144047 None code15 Supplying and mounting 2Nos. Of 2Way 6A flush type switches either surface / flush mounted unexisting gang box or 4mm thick platic sheet and mounted on a flush mounted wooden box and a wiring as per IS 1293 Item No.3.2 Page No.5 SR 2021-22 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Nos. 162.0 162.0 14.0 False None None False None False 2268.0 0 3798217 144047 None code16 Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular switches plates, the box should be firmly flush mounted after due groove cutting in brick / stone / C.C. work. Item No.3.4 Page No.5 3.4.1 1-3way ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No 15.0 15.0 10.0 False None None False None False 150.0 0 3798218 144047 None code17 3.4.2 4-5way ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No 4.0 4.0 14.0 False None None False None False 56.0 0 3798219 144047 None code18 3.4.3 6 Way ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No 4.0 4.0 14.0 False None None False None False 56.0 0 3798220 144047 None code19 3.4.4 8Way ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No 2.0 2.0 14.0 False None None False None False 28.0 0 3798221 144047 None code20 3.4.5 10-12way ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No 2.0 2.0 14.0 False None None False None False 28.0 0 3798222 144047 None code21 Supplyng and fixing superior quality modular switch monting poly carbonate plate with necessary suporting back plate with required nos of machine screws, bolts nuts etc, complete on the existing metal / PVC box. Item No. 3.5 Page No.5 3.5.1 1 to 3 module ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No 152.0 152.0 88.0 False None None False None False 13376.0 0 3798223 144047 None code22 3.5.2 4 module ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No 175.0 175.0 10.0 False None None False None False 1750.0 0 3798224 144047 None code23 Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Item No.3.6 P.No.5 SR 2021-22 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No 175.0 175.0 10.0 False None None False None False 1750.0 0 3798225 144047 None code24 Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Item No.3.6 P.No.5 SR 2021-223.6.1 6A one way switch ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No 88.0 88.0 15.0 False None None False None False 1320.0 0 3798226 144047 None code25 Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Item No.3.6 P.No.5 SR 2021-223.6.2 6A Two way switch ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No 152.0 152.0 4.0 False None None False None False 608.0 0 3798227 144047 None code26 Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Item No.3.6 P.No.5 SR 2021-223.6.3 6A Three way socket ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No 162.0 162.0 4.0 False None None False None False 648.0 0 3798228 144047 None code27 Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Item No.3.6 P.No.5 SR 2021-223.6.4 stepped fan regular two module ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No 313.0 313.0 2.0 False None None False None False 626.0 0 3798229 144047 None code28 Supplying and fixing hylum plastic sheet 3mm thck with necessary nitches for fixing switches regulators etc and fixing on existing wood or metal box using N.F. Screws. Item No. 3.9 Page No. 6 2021-22 Electrical SR ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Sqm 0.26 0.26 200.0 False None None False None False 52.0 0 3798230 144047 None code29 Supplying and fixig PBBC / backelite straight or slant batten holder and wiring with 60W / 230 Volts lamps 4.2 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No. 88.0 88.0 15.0 False None None False None False 1320.0 0 3798231 144047 None code30 Supplying and fixing cast Aluminum round or oblong type bulk head fitting with G.. Wire guard glass cover with 15watt 230V CFL Lamps as required. Item No.4.4 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No. 952.0 952.0 20.0 False None None False None False 19040.0 0 3798232 144047 None code31 Supplying buy type suitable 28W TS single / twin lamp a suspension mounted luminaire and optical reflector prewired with HF Electronic ballast push ft type lamp holder and main connector channels cover shallbe made of CRCA MS sheet and finishing is done withstore enameled white with end caps made of Engineering plaster. 1x4x28wall ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No. 990.0 990.0 6.0 False None None False None False 5940.0 0 3798233 144047 None code32 Supplying and fixing o porcelain fuse channel with cut out on existing wooden / panel usng necessary nuts and bolts and washers 32Amps. ---- CLASS-3 PWD VALID CONTRACTOR LICENCE No. 180.0 180.0 4.0 False None None False None False 720.0 0 3798234 144047 None code33 Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing material and 'C' type curve, indicator ON/OFF energy cross-3 with short circuit breaking cpacity of /OK and complete wiring as required. 5.32 amps 5P ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Each 418.0 418.0 2.0 False None None False None False 836.0 0 3798235 144047 None code34 5.32 amps DP ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Each 849.0 849.0 2.0 False None None False None False 1698.0 0 3798236 144047 None code35 Supplying and fixing reglar MCB distribution boars on wall /wood board/ flush mounting box using required clamps bolts nuts etc., wit provision for fixing suiteable type capacity MCB single phase / 3 phase / single door with powder coate painting made out of 14SWG MS encloser. Item No. 6.10 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Each 1067.0 1067.0 2.0 False None None False None False 2134.0 0 3798237 144047 None code36 Supplying fixing and wiring earth leakage minature circuit breaker (ELMCB) 240/450V/up to 300 MA Sensitivity on existing wood / pannel board 6.183 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Each 2623.0 2623.0 2.0 False None None False None False 5246.0 0 3798238 144047 None code37 Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz AC supply complete.12" Sweep 300mm ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Each 1800.0 1800.0 4.0 False None None False None False 7200.0 0 3798239 144047 None code38 Supplying capacitor type ceiling fan complete with down rod blades shackle canopies etcs for operation on 230 Volts 50 Cycles single phase AC supply confirming to ISS 374-1979 and with double ball bearing system as per technical data.48" Sweep 120mm ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Each 2376.0 2376.0 2.0 False None None False None False 4752.0 0 3798240 144047 None code39 Fixing all types and all capacited of Fluorescent / false celing spot light / CFL / LED fitting indoor on the wall / ceiling ratter girders using 23/0.0076" twin twisted PVC Insulated wires required Nos of round blocks and clamps. ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Each 98.0 98.0 15.0 False None None False None False 1470.0 0 3798241 144047 None code40 Fixing and ceiling / wall mounting fan at all capacities and all types with necessary clamps and "S" hook made out 15mm dia M.S. rod with 5 clamps ceiling rose of approved quality with necessary length of 23/0.0076: PVC insulated twin twisted wire of approved quality, mounted on suitable size wooden board and wire. 17.5 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Each 237.0 237.0 2.0 False None None False None False 474.0 0 3798242 144047 None code41 Extra length of GI pipe of class B 19mm dia for downrod ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Mtr 164.0 164.0 2.5 False None None False None False 410.0 0 3798243 144047 None code42 Fixing one exhast fan in the nitch already left in the wall with bolts nuts 5amps ceilng rose with sufficient length of 23/0.0076" PVC insulated twin core wire 17.2. ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Each 412.0 412.0 4.0 False None None False None False 1648.0 0 1723895370000 0 None None Buildings CONSTRUCTION OF TOILET BLOCKS AT SWM SITE 469653.57
id tenderSubEstimateId categoryName itemCode description uomName baseRate finalRate quantity modifyQuantityYn minQuantity maxQuantity buyBackYn buyBackValue hideYn netAmount taxCount 3798244 144048 None code01 Earth work Excavation for foundation of structure upto 3mtr by mechanical means as per drawing technical specification inculding setting out providing shoring, strutting and fencing removla of strumps and other deleterou matter dressing of sides and bottom filling back the excavated earth to the extent required and utilising / transporting the remaining earth upto 1.0KM lead including cost of labour CM SR 2021-22 Page No.8 Vol-1 Item No.1.14.1 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Cum 75.19 75.19 21.4056 False None None False None False 1609.487064 0 3798245 144048 None code02 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) CM SR 2021-22 P.No.15 Volume -1 Item No.2.1.3 Mix 1:3:6 (M10) - 40mm D/S ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Cum 5720.62 5720.62 2.3 False None None False None False 13157.426 0 3798246 144048 None code03 Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) I.No. 2.2.1.1 P.No.15 Volume-1 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Cum 6610.0 6610.0 1.728 False None None False None False 11422.08 0 3798247 144048 None code04 Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) I.No. 2.2.2.1 P.No.15 Volume-1 CM SR 2021-22 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Cum 6774.0 6774.0 1.72 False None None False None False 11651.28 0 3798248 144048 None code05 Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) P.No. 17 Vol-1 Item No. 2.5.2 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Cum 7645.0 7645.0 2.37 False None None False None False 18118.65 0 3798249 144048 None code06 Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) P.No. 17 Vol-1 Item No. 2.5.2 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Cum 7423.2 7423.2 10.26 False None None False None False 76162.032 0 3798250 144048 None code07 Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately).Item No. 11.32 P.No.81 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Kg 94.76 94.76 660.8 False None None False None False 62617.408 0 3798251 144048 None code08 Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : I.No. 5.1.1 P.No.9 Vol-2 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Cum 4892.5 4892.5 15.18 False None None False None False 74268.15 0 3798252 144048 None code09 Filling available excavated earth (excluding rock) in trench plinth sides of foundation and othr Similar works etc in layer not exceeding 20cm in depth consolidating each disposal layer by ramming and watering lead up to 50m and lift up to 1.5m. CM SR 2021-22 P.No.115 Vol-1 Item No.1.9 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Cum 210.12 210.12 4.608 False None None False None False 968.23296 0 3798253 144048 None code10 Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Item No.6.4 P.No. 13 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Cum 7635.39 7635.39 13.53 False None None False None False 103306.8267 0 3798254 144048 None code11 Providing 20mm plaster mix 1:4 (1 Cement 4 fine sand) to brick /stone masonry including rounding off corners whereas required smooth rendering providng and remvoing scaffolding including cost material and laboru. SR 2021-22 / P.No.41 Vol-2 Item No. 8.3.1 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Sqm 307.97 307.97 95.433 False None None False None False 29390.50101 0 3798255 144048 None code12 Providing 15mm thick plaster on the rough side of single or half brick wall of mix 1:4 (1 cement 4 fine sand) inclduing rounding off corner wherever required smooth rendering Providing and removing scafoling including cost of materials labour curring complete as per specification and as per direction of Engineer incharge CM SR 2021-22 P.No. 41 Vol-2 Item No. 8.2.1 Upto 3.5M ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Sqm 282.22 282.22 87.048 False None None False None False 24566.68656 0 3798256 144048 None code13 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Item No. 11.34(A) P.No. 85 Vol-2 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Kg 134.93 134.93 30.24 False None None False None False 4080.2832 0 3798257 144048 None code14 Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges. CMSR 2021-22 VOL-2 P.No. 106 Item No.12.55 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Mtr 3917.09 3917.09 6.3 False None None False None False 24677.667 0 3798258 144048 None code15 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: Item No. 14.1 P.No.121 ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Mtr 4373.38 4373.38 2.0 False None None False None False 8746.76 0 3798259 144048 None code16 Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. If the height of embankment construction is more than 1.50 m add 5 per mfor every 1.50 m height or part there off, Deduct 5 per if rollers are not used and tamping is done manually Add 8per m for works under foul & sullage situation ---- CLASS-3 PWD VALID CONTRACTOR LICENCE Cum 414.06 414.06 11.8584 False None None False None False 4910.089104 0 generalCriterionList
createdTs version createdDate modifiedDate criterionType description tenderEligibilityCriterionDocumentList 1723895371000 0 None None ELIGIBILITY Tenders from Joint ventures are not acceptable. None 1723895371000 0 None None ELIGIBILITY Bidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None 1723895371000 0 None None ELIGIBILITY Bidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document. None 1723895371000 0 None None ELIGIBILITY It shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission. None 1723895371000 0 None None ELIGIBILITY EMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection. None 1723895399000 0 None None ELIGIBILITY CLASS-3 PWD VALID CONTRACTOR LICENCE None 1723895416000 0 None None ELIGIBILITY SIMILER NATURE OF WORKDONE CERTIFICATE FROM COMPETENT AUTHORITY 50% None 1723895442000 0 None None ELIGIBILITY TURNOVER CERTIFICATE FROM CA None 1723895455000 0 None None ELIGIBILITY BELOW DD None 1723895463000 0 None None ELIGIBILITY LATEST ITR COPY None 1723895471000 0 None None ELIGIBILITY GST REG CERTIFICATE None 1723895481000 0 None None ELIGIBILITY REMAINING CONDITIONS AS PER KW-1 None preQualCriterionList None technicalCriterionList
createdTs version createdDate modifiedDate description criterionCategoryText criterionTypeOthersValue tenderTechnicalCriterionDocumentList None None None None Department Registration Details None None None None None None Total value of civl engineering works executed and payments received in the last five years (year-wise) None None None None None None List of existing commitments and ongoing work None None None None None None List of works for which tenders already submitted None None None None None None Banker Details None None None None None None SIMILER NATURE OF WORKDONE CERTIFICATE FROM COMPETENT AUTHORITY 50% Past Experience None
createdTs version createdDate modifiedDate documentName None None None None Work Done Certificate None None None None CLASS-3 PWD VALID CONTRACTOR LICENCE Capabilities of Vendor None
createdTs version createdDate modifiedDate documentName None None None None PWD Registration Certificate (Class I/II/III/IV) None None None None TURNOVER CERTIFICATE FROM CA Financial Status None
createdTs version createdDate modifiedDate documentName None None None None Audited CA Certificate of Annual Turnover None None None None BELOW DD Financial Status None
createdTs version createdDate modifiedDate documentName None None None None Line of Credit None None None None SITE INSPECTION LETTER FROM TP LOKAPUR Others SITE INSPECTION LETTER FROM TP LOKAPUR
createdTs version createdDate modifiedDate documentName None None None None Others -- SITE INSPECTION LETTER FROM TP LOKAPUR tenderCriterionDocumentList
documentName optional documentTypeText Annual Turnover Certificate False Technical Bid Company Registration Certificate False Technical Bid Reserved Category Certificate False Technical Bid Small Scale Industries Certificate False Technical Bid tenderWorkLocationList
tenderSubEstimateName districtName taluqName loksabhaContName assemblyContName locationDescription latitudeDegrees latitudeMinutes latitudeSeconds longitudeDegrees longitudeMinutes longitudeSeconds Buildings Bagalkote Mudhol Bagalkot MUDHOL (SC) LOKAPUR TP None None None None None None Buildings Bagalkote Mudhol Bagalkot MUDHOL (SC) lokapur None None None None None None tenderAddress None tenderRecallDTO None