tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1722863788000 | 0 | None | None | Buildings | Construction of Proposed Building | 11902492.27 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3697193 | 136007 | None | CSR 2023-24 Vol - I Chapter - 1 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m. | Cum | 107.1 | 107.1 | 351.34 | False | None | None | False | None | False | 37628.514 | 0 | 3697194 | 136007 | None | CSR 2023-24 Vol - II Chapter-4 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 123.9 | 123.9 | 234.24 | False | None | None | False | None | False | 29022.336 | 0 | 3697195 | 136007 | None | CSR 2023-24 Vol - I Chapter - 2 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 6288.45 | 6288.45 | 79.06 | False | None | None | False | None | False | 497164.857 | 0 | 3697196 | 136007 | None | CSR 2023-24 Vol - I 2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Footings (Including 8% for Centering) | Cum | 7159.68 | 7159.68 | 107.1 | False | None | None | False | None | False | 766801.728 | 0 | 3697197 | 136007 | None | CSR 2023-24 Vol - I 2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 11088.0 | 11088.0 | 8.67 | False | None | None | False | None | False | 96132.96 | 0 | 3697198 | 136007 | None | CSR 2023-24 Vol - II 5.2 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 82.02 | False | None | None | False | None | False | 483224.931 | 0 | 3697199 | 136007 | None | CSR 2021-22 Vol - I 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Columns (Including 70% for Centering) | Cum | 11975.25 | 11975.25 | 124.23 | False | None | None | False | None | False | 1487685.3075 | 0 | 3697200 | 136007 | None | CSR 2021-22 Vol - I 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plinth Beam (Including 50% for Centering) | Cum | 10606.65 | 10606.65 | 13.27 | False | None | None | False | None | False | 140750.2455 | 0 | 3697201 | 136007 | None | CSR 2021-22 Vol - I 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Roof Beam, Lintle & Chejja (Including 60% for Centering) | Cum | 11290.95 | 11290.95 | 53.55 | False | None | None | False | None | False | 604630.3725 | 0 | 3697202 | 136007 | None | CSR 2023-24 Vol - II 6.8 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 1252.75 | False | None | None | False | None | False | 349893.075 | 0 | 3697203 | 136007 | None | CSR 2023-24 Vol - II 6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 81.78 | False | None | None | False | None | False | 684290.061 | 0 | 3697204 | 136007 | None | CSR 2023-24 Vol - II 8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 1383.51 | False | None | None | False | None | False | 370434.8025 | 0 | 3697205 | 136007 | None | CSR 2023-24 Vol - II 8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 404.25 | 404.25 | 466.86 | False | None | None | False | None | False | 188728.155 | 0 | 3697206 | 136007 | None | CSR 2023-24 Vol - II 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 1383.51 | False | None | None | False | None | False | 145268.55 | 0 | 3697207 | 136007 | None | CSR 2023-24 Vol - II 9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 2589.3 | 2589.3 | 556.32 | False | None | None | False | None | False | 1440479.376 | 0 | 3697208 | 136007 | None | CSR 2023-24 Vol - II 8.27 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 55.65 | 55.65 | 1383.51 | False | None | None | False | None | False | 76992.3315 | 0 | 3697209 | 136007 | None | CSR 2023-24 Vol - II 9.38 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1461.6 | 1461.6 | 315.65 | False | None | None | False | None | False | 461354.04 | 0 | 3697210 | 136007 | None | CSR 2023-24 Vol - II 8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 1383.51 | False | None | None | False | None | False | 199017.9135 | 0 | 3697211 | 136007 | None | CSR 2023-24 Vol - II 8.31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 186.9 | 186.9 | 466.86 | False | None | None | False | None | False | 87256.134 | 0 | 3697212 | 136007 | None | CSR 2023-24 Vol - II 11.3 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 8689.8 | 8689.8 | 29.38 | False | None | None | False | None | False | 255306.324 | 0 | 3697213 | 136007 | None | CSR 2023-24 Vol - II 12.12 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 130412.1 | 130412.1 | 2.17 | False | None | None | False | None | False | 282994.257 | 0 | 3697214 | 136007 | None | CSR 2023-24 Vol - II 12.15 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Cum | 7241.85 | 7241.85 | 6.3 | False | None | None | False | None | False | 45623.655 | 0 | 3697215 | 136007 | None | CSR 2023-24 Vol - II 12.75.5 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 75x65x4 mm (heavy type) | Each | 177.45 | 177.45 | 84.0 | False | None | None | False | None | False | 14905.8 | 0 | 3697216 | 136007 | None | CSR 2023-24 Vol - II 12.76.2 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm | Each | 456.75 | 456.75 | 52.0 | False | None | None | False | None | False | 23751.0 | 0 | 3697217 | 136007 | None | CSR 2023-24 Vol - II 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. | Kg | 176.4 | 176.4 | 695.6 | False | None | None | False | None | False | 122703.84 | 0 | 3697218 | 136007 | None | CSR 2023-24 Vol - I 2.11A | Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications. | t | 93929.85 | 93929.85 | 32.05 | False | None | None | False | None | False | 3010451.6925 | 0 |
| 1722863788000 | 0 | None | None | Buildings | For Electrical of construction cost | 699447.4 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3697219 | 136008 | None | ElectricaL SR 2023-24 It. No. 1.2 Pg. No.3 of 105 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary | m | 81.9 | 81.9 | 600.0 | False | None | None | False | None | False | 49140.0 | 0 | 3697220 | 136008 | None | SR 2023-24 It. No. 1.3 Pg. No. 3 of 105 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary | m | 82.95 | 82.95 | 50.0 | False | None | None | False | None | False | 4147.5 | 0 | 3697221 | 136008 | None | SR 2023-24 It. No. 2.2.1 Pg. No. 6 of 105 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. | Point | 282.45 | 282.45 | 18.0 | False | None | None | False | None | False | 5084.1 | 0 | 3697222 | 136008 | None | SR 2023-24 It. No. 2.2.2 Pg. No. 6 of 105 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. | Point | 397.95 | 397.95 | 26.0 | False | None | None | False | None | False | 10346.7 | 0 | 3697223 | 136008 | None | SR 2023-24 It. No. 2.2.3 Pg. No. 6 of 105 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. | Point | 582.75 | 582.75 | 50.0 | False | None | None | False | None | False | 29137.5 | 0 | 3697224 | 136008 | None | SR 2023-24 It. No. 3.14 Pg. No. 11 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. | Each | 77.7 | 77.7 | 63.0 | False | None | None | False | None | False | 4895.1 | 0 | 3697225 | 136008 | None | SR 2023-24 It. No. 11.3 Pg. No. 43 of 105 | Supplying of .feet -PVC Batten with integrated LED tube with high quality diffuser with Life of 25000 burning hours & 70percent lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition | Each | 1332.45 | 1332.45 | 60.0 | False | None | None | False | None | False | 79947.0 | 0 | 3697226 | 136008 | None | SR 2023-24 It. No. 13.7. Pg. No. 56 of 105 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps | Each | 128.1 | 128.1 | 60.0 | False | None | None | False | None | False | 7686.0 | 0 | 3697227 | 136008 | None | SR 2023-24 It. No. 6.3 Pg. No. 30 of 105 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system | Each | 3133.2 | 3133.2 | 25.0 | False | None | None | False | None | False | 78330.0 | 0 | 3697228 | 136008 | None | SR 2023-24 It. No. 13.10 Pg. No. 57 of 105 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 179.55 | 179.55 | 25.0 | False | None | None | False | None | False | 4488.75 | 0 | 3697229 | 136008 | None | SR 2023-24 It. No. 3.6.4 Pg. No. 10 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 | Each | 374.85 | 374.85 | 25.0 | False | None | None | False | None | False | 9371.25 | 0 | 3697230 | 136008 | None | SR 2023-24 It. No. 1.13 Pg. No. 4 of 105 | Supplying And Fixing Metal Fan Box with Round Hook. | Each | 122.85 | 122.85 | 25.0 | False | None | None | False | None | False | 3071.25 | 0 | 3697231 | 136008 | None | SR 2023-24 It. No. 3.6.2 Pg. No. 10 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 | Each | 107.1 | 107.1 | 122.0 | False | None | None | False | None | False | 13066.2 | 0 | 3697232 | 136008 | None | SR 2023-24 It. No. 3.6.3 Pg. No. 10 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. | Each | 179.55 | 179.55 | 30.0 | False | None | None | False | None | False | 5386.5 | 0 | 3697233 | 136008 | None | SR 2023-24 It. No. 3.6.7 Pg. No. 10 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. | Each | 189.0 | 189.0 | 10.0 | False | None | None | False | None | False | 1890.0 | 0 | 3697234 | 136008 | None | SR 2023-24 It. No. 3.6.10 Pg. No. 10 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 | Each | 247.8 | 247.8 | 10.0 | False | None | None | False | None | False | 2478.0 | 0 | 3697235 | 136008 | None | SR 2023-24 It. No. 3.6.9 Pg. No. 10 of 105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. | Each | 342.3 | 342.3 | 20.0 | False | None | None | False | None | False | 6846.0 | 0 | 3697236 | 136008 | None | SR 2023-24 It. No.3.4.1 Pg. No. 8 of 105 | Supplying and flush mounting powder coated OR galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickOR Stone OR C.C wall | Each | 144.9 | 144.9 | 20.0 | False | None | None | False | None | False | 2898.0 | 0 | 3697237 | 136008 | None | SR 2023-24 It. No.3.4.4 Pg. No. 8 of 105 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall | Each | 231.0 | 231.0 | 4.0 | False | None | None | False | None | False | 924.0 | 0 | 3697238 | 136008 | None | SR 2023-24 It. No.3.4.6 Pg. No. 8 of 105 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall | Each | 334.95 | 334.95 | 2.0 | False | None | None | False | None | False | 669.9 | 0 | 3697239 | 136008 | None | SR 2023-24 It. No.3.4.8 Pg. No. 8 of 105 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wal | Each | 425.25 | 425.25 | 12.0 | False | None | None | False | None | False | 5103.0 | 0 | 3697240 | 136008 | None | SR 2023-24 It. No. 3.5.1 Pg. No. 9 of 105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box | Each | 143.85 | 143.85 | 20.0 | False | None | None | False | None | False | 2877.0 | 0 | 3697241 | 136008 | None | SR 2023-24 It. No. 3.5.4 Pg. No. 9 of 105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. | Each | 245.7 | 245.7 | 4.0 | False | None | None | False | None | False | 982.8 | 0 | 3697242 | 136008 | None | SR 2023-24 It. No. 3.5.6 Pg. No. 9 of 105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. | Each | 361.2 | 361.2 | 2.0 | False | None | None | False | None | False | 722.4 | 0 | 3697243 | 136008 | None | SR 2023-24 It. No. 3.5.8 Pg. No. 9 of 105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. | Each | 479.85 | 479.85 | 12.0 | False | None | None | False | None | False | 5758.2 | 0 | 3697244 | 136008 | None | SR 2023-24 It. No. 2.3.2 Pg. 6 of 105 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 | m | 27.3 | 27.3 | 1950.0 | False | None | None | False | None | False | 53235.0 | 0 | 3697245 | 136008 | None | SR 2023-24 It. No. 2.3.5 Pg. 6 of 105 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 | m | 44.1 | 44.1 | 800.0 | False | None | None | False | None | False | 35280.0 | 0 | 3697246 | 136008 | None | SR 2023-24 It. No. 2.3.4 Pg. 6 of 105 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 | m | 66.15 | 66.15 | 650.0 | False | None | None | False | None | False | 42997.5 | 0 | 3697247 | 136008 | None | SR 2023-24 It. No. 5.19 Pg. No. 18 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure | Each | 2445.45 | 2445.45 | 2.0 | False | None | None | False | None | False | 4890.9 | 0 | 3697248 | 136008 | None | SR 2023-24 It. No. 5.42 Pg. No. 20 of 105 | Fabricating supplying and mounting MS box made out SWGsuitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete | Sqm | 0.45 | 0.45 | 50000.0 | False | None | None | False | None | False | 22500.0 | 0 | 3697249 | 136008 | None | SR 2023-24 It. No. 5.12 Pg. No. 15 of 105 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) | Each | 16011.45 | 16011.45 | 1.0 | False | None | None | False | None | False | 16011.45 | 0 | 3697250 | 136008 | None | SR 2023-24 It. No. 5.15 Pg. No. 16 of 105 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism | Each | 18166.05 | 18166.05 | 1.0 | False | None | None | False | None | False | 18166.05 | 0 | 3697251 | 136008 | None | SR 2023-24 It. No.5.14.3 Pg. No. 16 of 105 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947 | Each | 10648.05 | 10648.05 | 1.0 | False | None | None | False | None | False | 10648.05 | 0 | 3697252 | 136008 | None | SR 2023-24 It. No. 5.40 Pg. No. 20 of 105 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete | m | 2588.25 | 2588.25 | 4.0 | False | None | None | False | None | False | 10353.0 | 0 | 3697253 | 136008 | None | SR It. No. 5.41.2 Pg. No. 20 of 105 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. | m | 414.75 | 414.75 | 6.0 | False | None | None | False | None | False | 2488.5 | 0 | 3697254 | 136008 | None | SR 2023-24 It. No. 5.29 Pg. No. 19 of 105 | Supplying,fixing and wiring 3 Phase Digital Ammeter /Voltmeter | m | 1496.25 | 1496.25 | 1.0 | False | None | None | False | None | False | 1496.25 | 0 | 3697255 | 136008 | None | SR 2023-24 It. No. 5.35 Pg. No. 19 of 105 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter | Each | 5990.25 | 5990.25 | 1.0 | False | None | None | False | None | False | 5990.25 | 0 | 3697256 | 136008 | None | SR 2023-24 It. No. 5.38 Pg. No. 19-105 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C | Each | 540.75 | 540.75 | 3.0 | False | None | None | False | None | False | 1622.25 | 0 | 3697257 | 136008 | None | SR 2023-24 It. No. 5.18.1 Pg. No. 17 of 105 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. | Each | 435.75 | 435.75 | 15.0 | False | None | None | False | None | False | 6536.25 | 0 | 3697258 | 136008 | None | SR 2023-24 It. No. 5.18.4 Pg. No. 17 of 105 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. | Each | 775.95 | 775.95 | 10.0 | False | None | None | False | None | False | 7759.5 | 0 | 3697259 | 136008 | None | SR 2023-24 It. No. 5.18.9 Pg. No. 17 of 105 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. | Each | 3242.4 | 3242.4 | 2.0 | False | None | None | False | None | False | 6484.8 | 0 | 3697260 | 136008 | None | SR 2023-24 It. No. 11.8.3 Pg. No.45 of 105 | LED Light fixture with .W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree Nichia Lumileds Osram make LED Source. | Each | 10563.0 | 10563.0 | 5.0 | False | None | None | False | None | False | 52815.0 | 0 | 3697261 | 136008 | None | SR 2023-24 It. No. 13.2 Pg. No. 57 of 105 | Supplying and Fixing.mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. | Each | 1263.15 | 1263.15 | 5.0 | False | None | None | False | None | False | 6315.75 | 0 | 3697262 | 136008 | None | It. No. 32.12 Pg. No.13.8 Sl. No. 208 | Supplying LTUG cable 50 sqmm 3.5 core (Part II BESCOM) | Km | 217553.7 | 217553.7 | 0.1 | False | None | None | False | None | False | 21755.37 | 0 | 3697263 | 136008 | None | It. No. 21.06 Pg. No. 52.81 Sl. No. 175 | Laying LT Cable (35 to 95 sqm) part II GESCOM | Km | 32695.95 | 32695.95 | 0.1 | False | None | None | False | None | False | 3269.595 | 0 | 3697264 | 136008 | None | Bescom II 2023-24 It. No. 29.03 Pg. No. 63.81 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In hard soil | Cum | 408.45 | 408.45 | 37.5 | False | None | None | False | None | False | 15316.875 | 0 | 3697265 | 136008 | None | BESCOM CSR 2023-24 Part IV It. No. 29.07, Pg. No. | Refilling the Cable Trenches with selected soil including cost of all materials, labour HOM Loading and Unloading curing with all leads and lifts etc complete as per specifications | Cum | 60.9 | 60.9 | 37.0 | False | None | None | False | None | False | 2253.3 | 0 | 3697266 | 136008 | None | PWD Electrical SR 2023-24 It. No. 12.56 Pg. No. 54 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | Each | 3685.5 | 3685.5 | 4.0 | False | None | None | False | None | False | 14742.0 | 0 | 3697267 | 136008 | None | PWD SR 2023-24 It. No. 10.1 Pg. No. 113 Vo.5 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete | m | 106.05 | 106.05 | 12.0 | False | None | None | False | None | False | 1272.6 | 0 |
|
|
---|