| 3850152 | 147061 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 273.98 | 273.98 | 37.44 | False | None | None | False | None | False | 10257.8112 | 0 |
| 3850153 | 147061 | None | 1.10 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications
| Cum | 164.8 | 164.8 | 53.43 | False | None | None | False | None | False | 8805.264 | 0 |
| 3850154 | 147061 | None | 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth Upto 3 m , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift up to 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work
| Cum | 105.06 | 105.06 | 320.57 | False | None | None | False | None | False | 33679.0842 | 0 |
| 3850155 | 147061 | None | 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately )- Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregate
| Cum | 6168.67 | 6168.67 | 32.57 | False | None | None | False | None | False | 200913.5819 | 0 |
| 3850156 | 147061 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6789.96 | 6789.96 | 18.52 | False | None | None | False | None | False | 125750.0592 | 0 |
| 3850157 | 147061 | None | 2.4.2 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For RCC Columns
| Cum | 10938.79 | 10938.79 | 14.47 | False | None | None | False | None | False | 158284.2913 | 0 |
| 3850158 | 147061 | None | 2.4.2a | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Plinth
| Cum | 9674.19 | 9674.19 | 15.14 | False | None | None | False | None | False | 146467.2366 | 0 |
| 3850159 | 147061 | None | 2.4.2b | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Coping
| Cum | 6512.69 | 6512.69 | 1.96 | False | None | None | False | None | False | 12764.8724 | 0 |
| 3850160 | 147061 | None | 2.5.1a | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed, coarse aggregates for RCC Columns
| Cum | 11469.9 | 11469.9 | 0.72 | False | None | None | False | None | False | 8258.328 | 0 |
| 3850161 | 147061 | None | 2.5.1b | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed, coarse aggregates for RCC Beams and Lintels
| Cum | 10806.9 | 10806.9 | 5.31 | False | None | None | False | None | False | 57384.639 | 0 |
| 3850162 | 147061 | None | 2.5.1c | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed, coarse aggregates for RCC Roof Slab and stair case
| Cum | 10143.9 | 10143.9 | 29.7 | False | None | None | False | None | False | 301273.83 | 0 |
| 3850163 | 147061 | None | 2.5.1d | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed, coarse aggregates for First floor RCC Roof Slab
| Cum | 10245.34 | 10245.34 | 5.44 | False | None | None | False | None | False | 55734.6496 | 0 |
| 3850164 | 147061 | None | 2.5.1e | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed, coarse aggregates for First floor RCC Lintels
| Cum | 10914.97 | 10914.97 | 0.65 | False | None | None | False | None | False | 7094.7305 | 0 |
| 3850165 | 147061 | None | 2.5.1f | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed, coarse aggregates for RCC Chejja
| Cum | 9812.4 | 9812.4 | 0.8 | False | None | None | False | None | False | 7849.92 | 0 |
| 3850166 | 147061 | None | 2.5 iia | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.
| 100 Sqm | 404.79 | 404.79 | 1.95 | False | None | None | False | None | False | 789.3405 | 0 |
| 3850167 | 147061 | None | 2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft pannealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 92140.71 | 92140.71 | 5.114 | False | None | None | False | None | False | 471207.59094 | 0 |
| 3850168 | 147061 | None | 2.11h | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft pannealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 81381.33 | 81381.33 | 3.992 | False | None | None | False | None | False | 324874.26936 | 0 |
| 3850169 | 147061 | None | 3.1 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work
| Cum | 87.55 | 87.55 | 176.68 | False | None | None | False | None | False | 15468.334 | 0 |
| 3850170 | 147061 | None | 4.1 A(V) | Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 (v) For Grading -V Material
| Cum | 2561.61 | 2561.61 | 50.0 | False | None | None | False | None | False | 128080.5 | 0 |
| 3850171 | 147061 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 6580.67 | 6580.67 | 126.51 | False | None | None | False | None | False | 832520.5617 | 0 |
| 3850172 | 147061 | None | 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
| Sqm | 1349.3 | 1349.3 | 347.19 | False | None | None | False | None | False | 468463.467 | 0 |
| 3850173 | 147061 | None | 6.32a | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. for First Floor
| Sqm | 1362.79 | 1362.79 | 97.29 | False | None | None | False | None | False | 132585.8391 | 0 |
| 3850174 | 147061 | None | 6.33 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
| Sqm | 1267.93 | 1267.93 | 214.08 | False | None | None | False | None | False | 271438.4544 | 0 |
| 3850175 | 147061 | None | 6.8.1 | Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification)
| Sqm | 1100.04 | 1100.04 | 504.0 | False | None | None | False | None | False | 554420.16 | 0 |
| 3850176 | 147061 | None | 8.42.3 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 150 mm size
| Sqm | 476.89 | 476.89 | 64.0 | False | None | None | False | None | False | 30520.96 | 0 |
| 3850177 | 147061 | None | 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 248.23 | 248.23 | 615.06 | False | None | None | False | None | False | 152676.3438 | 0 |
| 3850178 | 147061 | None | 8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin- charge.
| Sqm | 332.69 | 332.69 | 214.38 | False | None | None | False | None | False | 71322.0822 | 0 |
| 3850179 | 147061 | None | 8.7a | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Ground Floor
| Sqm | 376.98 | 376.98 | 423.27 | False | None | None | False | None | False | 159564.3246 | 0 |
| 3850180 | 147061 | None | 8.7b | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For First Floor
| Sqm | 380.75 | 380.75 | 77.73 | False | None | None | False | None | False | 29595.6975 | 0 |
| 3850181 | 147061 | None | 8.9a | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Ground Floor
| Sqm | 382.13 | 382.13 | 54.98 | False | None | None | False | None | False | 21009.5074 | 0 |
| 3850182 | 147061 | None | 8.9b | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For First Floor
| Sqm | 385.95 | 385.95 | 86.76 | False | None | None | False | None | False | 33485.022 | 0 |
| 3850183 | 147061 | None | 8.10a | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Ground floor
| Sqm | 217.33 | 217.33 | 38.91 | False | None | None | False | None | False | 8456.3103 | 0 |
| 3850184 | 147061 | None | 8.10b | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For First floor
| Sqm | 219.5 | 219.5 | 38.91 | False | None | None | False | None | False | 8540.745 | 0 |
| 3850185 | 147061 | None | 8.30a | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. For ground Floor
| Sqm | 179.22 | 179.22 | 400.52 | False | None | None | False | None | False | 71781.1944 | 0 |
| 3850186 | 147061 | None | 8.30b | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. for First Floor
| Sqm | 181.01 | 181.01 | 86.76 | False | None | None | False | None | False | 15704.4276 | 0 |
| 3850187 | 147061 | None | 8.31a | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. For ground Floor
| Sqm | 183.34 | 183.34 | 220.26 | False | None | None | False | None | False | 40382.4684 | 0 |
| 3850188 | 147061 | None | 8.31b | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. for First Floor
| Sqm | 185.17 | 185.17 | 116.64 | False | None | None | False | None | False | 21598.2288 | 0 |
| 3850189 | 147061 | None | 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 118.45 | 118.45 | 24.0 | False | None | None | False | None | False | 2842.8 | 0 |
| 3850190 | 147061 | None | 9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 L per 50 kg of cement or as per direction of Engineer incharge.
| Sqm | 824.0 | 824.0 | 21.96 | False | None | None | False | None | False | 18095.04 | 0 |
| 3850191 | 147061 | None | 9.9a | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. For Ground floor
| Sqm | 1108.28 | 1108.28 | 58.8 | False | None | None | False | None | False | 65166.864 | 0 |
| 3850192 | 147061 | None | 9.9b | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. For First floor
| Sqm | 1119.36 | 1119.36 | 10.8 | False | None | None | False | None | False | 12089.088 | 0 |
| 3850193 | 147061 | None | 9.21.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately Size of Tile 600x600 mm
| Sqm | 1275.14 | 1275.14 | 44.6 | False | None | None | False | None | False | 56871.244 | 0 |
| 3850194 | 147061 | None | 9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
| Sqm | 2539.98 | 2539.98 | 1.47 | False | None | None | False | None | False | 3733.7706 | 0 |
| 3850195 | 147061 | None | 9.24a | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. Ground Floor
| Sqm | 2937.56 | 2937.56 | 53.91 | False | None | None | False | None | False | 158363.8596 | 0 |
| 3850196 | 147061 | None | 9.24b | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. First Floor
| Sqm | 2966.94 | 2966.94 | 51.37 | False | None | None | False | None | False | 152411.7078 | 0 |
| 3850197 | 147061 | None | 9.39a | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Ground Floor
| Sqm | 1492.47 | 1492.47 | 163.98 | False | None | None | False | None | False | 244735.2306 | 0 |
| 3850198 | 147061 | None | 9.39b | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. First Floor
| Sqm | 1507.39 | 1507.39 | 28.98 | False | None | None | False | None | False | 43684.1622 | 0 |
| 3850199 | 147061 | None | 10.2.2 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia.
| m | 296.64 | 296.64 | 135.0 | False | None | None | False | None | False | 40046.4 | 0 |
| 3850200 | 147061 | None | 11.25.2 | Providing and fixing Steel work welded in built up sections framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge.
| Kg | 140.08 | 140.08 | 909.13 | False | None | None | False | None | False | 127350.9304 | 0 |
| 3850201 | 147061 | None | 11.26.3 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg / M | 188.49 | 188.49 | 687.99 | False | None | None | False | None | False | 129679.2351 | 0 |
| 3850202 | 147061 | None | 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.
| m | 327.54 | 327.54 | 23.12 | False | None | None | False | None | False | 7572.7248 | 0 |
| 3850203 | 147061 | None | 12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.-do- with both side prelam
| Sqm | 2436.98 | 2436.98 | 6.3 | False | None | None | False | None | False | 15352.974 | 0 |
| 3850204 | 147061 | None | 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 5890.57 | 5890.57 | 10.08 | False | None | None | False | None | False | 59376.9456 | 0 |
| 3850205 | 147061 | None | 12.86 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 5551.7 | 5551.7 | 13.68 | False | None | None | False | None | False | 75947.256 | 0 |
| 3850206 | 147061 | None | 12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm
| Rmtr | 723.06 | 723.06 | 73.0 | False | None | None | False | None | False | 52783.38 | 0 |
| 3850207 | 147061 | None | 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately); 30 mm thickness
| Sqm | 3589.55 | 3589.55 | 12.0 | False | None | None | False | None | False | 43074.6 | 0 |
| 3850208 | 147061 | None | 12.94.2 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately); 35 mm thickness
| Sqm | 4162.23 | 4162.23 | 13.2 | False | None | None | False | None | False | 54941.436 | 0 |
| 3850209 | 147061 | None | 13.3.2 | Providing and fixing brass stop cock of approved quality 20 mm nominal bore
| Each | 314.15 | 314.15 | 20.0 | False | None | None | False | None | False | 6283.0 | 0 |
| 3850210 | 147061 | None | 13.31.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes
| m | 249.26 | 249.26 | 125.0 | False | None | None | False | None | False | 31157.5 | 0 |
| 3850211 | 147061 | None | 13.31.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes
| m | 327.54 | 327.54 | 125.0 | False | None | None | False | None | False | 40942.5 | 0 |
| 3850212 | 147061 | None | 13.31.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.32 mm nominal dia Pipes
| m | 412.0 | 412.0 | 80.0 | False | None | None | False | None | False | 32960.0 | 0 |
| 3850213 | 147061 | None | 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
| Ltr | 9.27 | 9.27 | 7000.0 | False | None | None | False | None | False | 64890.0 | 0 |
| 3850214 | 147061 | None | 4.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
| Each | 5030.52 | 5030.52 | 1.0 | False | None | None | False | None | False | 5030.52 | 0 |
| 3850215 | 147061 | None | 14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. W.C. pan with ISI marked black solid plastic seat and lid
| Each | 6156.31 | 6156.31 | 4.0 | False | None | None | False | None | False | 24625.24 | 0 |
| 3850216 | 147061 | None | 14.4.1 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern
| Each | 4587.62 | 4587.62 | 3.0 | False | None | None | False | None | False | 13762.86 | 0 |
| 3850217 | 147061 | None | 14.7.5 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Angle back wash basin size 600 x 480 mm with single 15mm C.P. brass pillar tap
| Each | 2637.83 | 2637.83 | 2.0 | False | None | None | False | None | False | 5275.66 | 0 |
| 3850218 | 147061 | None | 14.7A | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
| Each | 4244.63 | 4244.63 | 3.0 | False | None | None | False | None | False | 12733.89 | 0 |
| 3850219 | 147061 | None | 14.8 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
| Each | 1465.69 | 1465.69 | 3.0 | False | None | None | False | None | False | 4397.07 | 0 |
| 3850220 | 147061 | None | 14.28.1.1 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia
| Each | 78.28 | 78.28 | 3.0 | False | None | None | False | None | False | 234.84 | 0 |
| 3850221 | 147061 | None | 14.37.1 | Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g
| Each | 315.18 | 315.18 | 3.0 | False | None | None | False | None | False | 945.54 | 0 |
| 3850222 | 147061 | None | 14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
| Each | 510.88 | 510.88 | 3.0 | False | None | None | False | None | False | 1532.64 | 0 |
| 3850223 | 147061 | None | 14.41 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 g
| Each | 517.06 | 517.06 | 3.0 | False | None | None | False | None | False | 1551.18 | 0 |
| 3850224 | 147061 | None | 14.85a | Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy
| Each | 1798.38 | 1798.38 | 3.0 | False | None | None | False | None | False | 5395.14 | 0 |
| 3850225 | 147061 | None | 14.92a | Providing and fixing Soap dish wired with 200mm width made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class
| Each | 739.54 | 739.54 | 3.0 | False | None | None | False | None | False | 2218.62 | 0 |
| 3850226 | 147061 | None | 14.93a | Providing and fixing Toilet paper holder made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy
| Each | 864.17 | 864.17 | 3.0 | False | None | None | False | None | False | 2592.51 | 0 |
| 3850227 | 147061 | None | 14.7.5 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Angle back wash basin size 600 x 480 mm with single 15mm C.P. brass pillar tap
| Each | 2637.83 | 2637.83 | 5.0 | False | None | None | False | None | False | 13189.15 | 0 |
| 3850228 | 147061 | None | 14.16A | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
| Each | 280.16 | 280.16 | 1.0 | False | None | None | False | None | False | 280.16 | 0 |
| 3850229 | 147061 | None | 14.32.4 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm
| Each | 1777.78 | 1777.78 | 5.0 | False | None | None | False | None | False | 8888.9 | 0 |
| 3850230 | 147061 | None | 15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.
| Sqm | 841.51 | 841.51 | 43.51 | False | None | None | False | None | False | 36614.1001 | 0 |
| 3850231 | 147061 | None | 15.10 | Newly Constructed Bathroom/toilet/balcony/utility with Cementatius Waterproof coating Below 300 m2 Providing and Applying CFTRI approved two componentflexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (1 Liquid: 2 Powder), to the RCC surface like bathroom, toilet, balcony & utility area applied @ 1.7kgm2 in 2 coats to achieve 1mm DFT, having Elongation at break 50% as per ASTM D 412, Tensile strength 1N mm2 as per ASTM D 412, Adhesion strength: 0.80 Nmm2 as per ASTM D 4541, crack bridging upto 1mm as per ASTM C 836, Water penetration (5 bar pressure) as per BS EN 12390. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification.
| Sqm | 378.01 | 378.01 | 11.6 | False | None | None | False | None | False | 4384.916 | 0 |
| 3850232 | 147061 | None | 16.10 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.
| Each | 4363.08 | 4363.08 | 8.0 | False | None | None | False | None | False | 34904.64 | 0 |
| 3850233 | 147061 | None | 16.62.2 | Providing to work spot rolling, lowering and placing in position RCC perforated rings in the already excavated pit including loading and unloading at both the destinations with all lead and lift with appurtenances., complete. 1200 mmx1250 mm
| Each | 9830.32 | 9830.32 | 8.0 | False | None | None | False | None | False | 78642.56 | 0 |
| 3850234 | 147061 | None | 1.2.1 | Concealed Conduit System : Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick
| Mtr | 66.0 | 66.0 | 110.0 | False | None | None | False | None | False | 7260.0 | 0 |
| 3850235 | 147061 | None | 1.3.1 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 19/20 mm dia 2 mm thick
| Mtr | 68.0 | 68.0 | 85.0 | False | None | None | False | None | False | 5780.0 | 0 |
| 3850236 | 147061 | None | 1.7.1 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50 mm conduit in brick wall
| Mtr | 29.0 | 29.0 | 65.0 | False | None | None | False | None | False | 1885.0 | 0 |
| 3850237 | 147061 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.
Short point upto 3m from tapping point to out let via switch box | Point | 269.0 | 269.0 | 16.0 | False | None | None | False | None | False | 4304.0 | 0 |
| 3850238 | 147061 | None | 2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.
Medium point above 3m upto 6m from tapping point to out let via switch box | Point | 379.0 | 379.0 | 7.0 | False | None | None | False | None | False | 2653.0 | 0 |
| 3850239 | 147061 | None | 2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2 1.5Sqmm (Phase Neutral) 1 1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) without control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block.complete for each outlet.Long point above 6m upto 10m from tapping point to out let via switch box | Point | 555.0 | 555.0 | 32.0 | False | None | None | False | None | False | 17760.0 | 0 |
| 3850240 | 147061 | None | 2.3.3 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 2.5 mm2 | m | 42.0 | 42.0 | 170.0 | False | None | None | False | None | False | 7140.0 | 0 |
| 3850241 | 147061 | None | 2.3.1 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 1.0 mm2
| m | 19.0 | 19.0 | 130.0 | False | None | None | False | None | False | 2470.0 | 0 |
| 3850242 | 147061 | None | 3.14.6 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Pendant Holder
| Nos | 71.0 | 71.0 | 28.0 | False | None | None | False | None | False | 1988.0 | 0 |
| 3850243 | 147061 | None | 5.18.4 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A DP
| Nos | 739.0 | 739.0 | 7.0 | False | None | None | False | None | False | 5173.0 | 0 |
| 3850244 | 147061 | None | 5.19.2 | Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure I - Single Door 6 Way SP & N
| Nos | 1186.0 | 1186.0 | 7.0 | False | None | None | False | None | False | 8302.0 | 0 |
| 3850245 | 147061 | None | 5.0 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker 6-32 A SP
| Nos | 336.54 | 336.54 | 7.0 | False | None | None | False | None | False | 2355.78 | 0 |
| 3850246 | 147061 | None | 6.2.2 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 15" Sweep (450 mm)
| Each | 4446.0 | 4446.0 | 3.0 | False | None | None | False | None | False | 13338.0 | 0 |
| 3850247 | 147061 | None | 11.3.3 | Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' 3640 W
| Nos | 1269.0 | 1269.0 | 12.0 | False | None | None | False | None | False | 15228.0 | 0 |
| 3850248 | 147061 | None | 11.11.5 | Supplying & fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.12W, 6500 K
| Nos | 269.0 | 269.0 | 18.0 | False | None | None | False | None | False | 4842.0 | 0 |
| 3850249 | 147061 | None | 13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.On wall/ ceiling / Rafter / Girders
| Nos | 122.0 | 122.0 | 22.0 | False | None | None | False | None | False | 2684.0 | 0 |
| 3850250 | 147061 | None | 13.11 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.
| Nos | 315.0 | 315.0 | 7.0 | False | None | None | False | None | False | 2205.0 | 0 |
| 3850251 | 147061 | None | 13.14 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.
| Nos | 492.0 | 492.0 | 7.0 | False | None | None | False | None | False | 3444.0 | 0 |
| 3850252 | 147061 | None | 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way
| Each | 220.0 | 220.0 | 7.0 | False | None | None | False | None | False | 1540.0 | 0 |
| 3850253 | 147061 | None | 3.4.7 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16 Way
| Each | 363.0 | 363.0 | 9.0 | False | None | None | False | None | False | 3267.0 | 0 |
| 3850254 | 147061 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal PVC box. 6 Module | Each | 234.0 | 234.0 | 7.0 | False | None | None | False | None | False | 1638.0 | 0 |
| 3850255 | 147061 | None | 3.5.7 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.16 Module
| Each | 397.0 | 397.0 | 9.0 | False | None | None | False | None | False | 3573.0 | 0 |
| 3850256 | 147061 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A One Way Switch
| Each | 102.0 | 102.0 | 46.0 | False | None | None | False | None | False | 4692.0 | 0 |
| 3850257 | 147061 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Three Way socket
| Each | 171.0 | 171.0 | 14.0 | False | None | None | False | None | False | 2394.0 | 0 |
| 3850258 | 147061 | None | 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped Fan Regulator Two Module
| Each | 357.0 | 357.0 | 7.0 | False | None | None | False | None | False | 2499.0 | 0 |
| 3850259 | 147061 | None | 3.6.7 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293
16A One Way Switch | Each | 180.0 | 180.0 | 11.0 | False | None | None | False | None | False | 1980.0 | 0 |
| 3850260 | 147061 | None | 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6 / 16A Universal socket
| Each | 236.0 | 236.0 | 11.0 | False | None | None | False | None | False | 2596.0 | 0 |
| 3850261 | 147061 | None | 3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293
32 A DP Switch | Nos | 326.0 | 326.0 | 7.0 | False | None | None | False | None | False | 2282.0 | 0 |
| 3850262 | 147061 | None | 6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
| Nos | 1492.0 | 1492.0 | 4.0 | False | None | None | False | None | False | 5968.0 | 0 |
| 3850263 | 147061 | None | 6.3.2 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 56" Sweep (1400 mm) Regular model .
| Nos | 3031.0 | 3031.0 | 8.0 | False | None | None | False | None | False | 24248.0 | 0 |
| 3850264 | 147061 | None | 1.6.1 | Digging of Pit for providing GI Pipe type Earthing.
| Per Pit | 578.0 | 578.0 | 7.0 | False | None | None | False | None | False | 4046.0 | 0 |
| 3850265 | 147061 | None | 53B | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.
| Nos | 3615.3 | 3615.3 | 7.0 | False | None | None | False | None | False | 25307.1 | 0 |