1724414348000 | 0 | None | None | Buildings | Construction of Coffee Godown Building At Arvathoklu, Gonikoppal In Kodagu District. | 2188652.59 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3849199 | 146987 | None | 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (P.No-8, I.No-1.12, PWD SR VOL-1 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Cum | 125.6 | 125.6 | 102.0 | False | None | None | False | None | False | 12811.2 | 0 | 3849200 | 146987 | None | 1.41.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m(P.No-8,( I.No-1.14.1, PWD SR VOL-1 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Cum | 134.8 | 134.8 | 43.07 | False | None | None | False | None | False | 5805.836 | 0 | 3849201 | 146987 | None | 2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. (P.No-15, I.No-2.1.3, PWD SR VOL-1 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Cum | 7915.1 | 7915.1 | 23.92 | False | None | None | False | None | False | 189329.192 | 0 | 3849202 | 146987 | None | 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(P.No-15, I.No-2.2.3, PWD SR VOL-1 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Cum | 9043.5 | 9043.5 | 18.37 | False | None | None | False | None | False | 166129.095 | 0 | 3849203 | 146987 | None | 2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
(P.No-16, I.No-2.3.2, PWD SR VOL-1 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Cum | 12846.0 | 12846.0 | 2.85 | False | None | None | False | None | False | 36611.1 | 0 | 3849204 | 146987 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(P.No-7, I.No-1.9, PWD SR VOL-1 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Cum | 351.5 | 351.5 | 65.02 | False | None | None | False | None | False | 22854.53 | 0 | 3849205 | 146987 | None | 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the topsurface ofconsolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.(P.No-5, I.No-4.1, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Sqm | 156.0 | 156.0 | 107.34 | False | None | None | False | None | False | 16745.04 | 0 | 3849206 | 146987 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (P.No-16, I.No-2.5.2, PWD SR VOL-1 2023-24) For Columns ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Cum | 15374.3 | 15374.3 | 3.5 | False | None | None | False | None | False | 53810.05 | 0 | 3849207 | 146987 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (P.No-16, I.No-2.5.2, PWD SR VOL-1 2023-24) For Lintels & Beams ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Cum | 14470.0 | 14470.0 | 3.81 | False | None | None | False | None | False | 55130.7 | 0 | 3849208 | 146987 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(P.No-16, I.No-2.5.1, PWD SR VOL-1 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Cum | 12705.2 | 12705.2 | 0.26 | False | None | None | False | None | False | 3303.352 | 0 | 3849209 | 146987 | None | 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.No-17, I.No-6.32 PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Sqm | 1731.3 | 1731.3 | 143.83 | False | None | None | False | None | False | 249012.879 | 0 | 3849210 | 146987 | None | 2.11 -a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings.(P.No-18, I.No-2.11-a, PWD SR VOL-1 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Tonne | 118226.3 | 118226.3 | 2.76 | False | None | None | False | None | False | 326304.588 | 0 | 3849211 | 146987 | None | 12.86 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(P.No-109, I.No-12.86, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Sqm | 7123.4 | 7123.4 | 7.02 | False | None | None | False | None | False | 50006.268 | 0 | 3849212 | 146987 | None | 11.34 B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.(P.No-86, I.No-11.34B, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Kgs | 241.9 | 241.9 | 147.42 | False | None | None | False | None | False | 35660.898 | 0 | 3849213 | 146987 | None | 11.6.1 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(P.No-78, I.No-11.6.1, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Sqm | 3479.8 | 3479.8 | 13.75 | False | None | None | False | None | False | 47847.25 | 0 | 3849214 | 146987 | None | 7.17 | Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications(P.No-23, I.No-7.17, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Sqm | 438.7 | 438.7 | 108.0 | False | None | None | False | None | False | 47379.6 | 0 | 3849215 | 146987 | None | 7.21 | Providing and fixing ridges, hips with asbestos cement sheet roofing with
G.I. J or L hooks, bolts and nuts 8mm. dia G.I.plain and bitumen washers,
serrated or plain wings, adjustable ridges, including cost of materials,
labour, complete as per(P.No-23, I.No-7.21, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 395.2 | 395.2 | 12.0 | False | None | None | False | None | False | 4742.4 | 0 | 3849216 | 146987 | None | 11.16.1 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Kg | 179.7 | 179.7 | 2169.29 | False | None | None | False | None | False | 389821.413 | 0 | 3849217 | 146987 | None | 7.6 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S.
sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers
etc., including making necessary connections with rain water pipes
complete. (0.63 mm thick with zinc coating not less than 275 g/m²) (P.No-20, I.No-7.6, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 692.5 | 692.5 | 13.0 | False | None | None | False | None | False | 9002.5 | 0 | 3849218 | 146987 | None | 7.6 | Providing & fixing flat iron brackets 50x3 mm size with necessary bolts,
nuts and washers etc. for fixing G.S. sheets gutters with purlin.(P.No-20, I.No-7.6, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 74.0 | 74.0 | 13.0 | False | None | None | False | None | False | 962.0 | 0 | 3849219 | 146987 | None | 8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(P.No-41, I.No-8.2.2, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Sqm | 368.8 | 368.8 | 146.51 | False | None | None | False | None | False | 54032.888 | 0 | 3849220 | 146987 | None | 8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement
: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(P.No-42, I.No-8.9, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Sqm | 508.8 | 508.8 | 175.07 | False | None | None | False | None | False | 89075.616 | 0 | 3849221 | 146987 | None | 2.1.6 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse ggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all material of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates(P.No-15, I.No-2.1.6, PWD SR VOL-1 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Cum | 8556.1 | 8556.1 | 5.72 | False | None | None | False | None | False | 48940.892 | 0 | 3849222 | 146987 | None | 8.35.2 | Providing and laying 60mm thick factory made cement concrete paver
block of approved shape and colour of M -30 grade made of C&D waste
by block making machine with vibratory compaction laid in required
pattern and including over 50mm thick compacted bed of coarse sand,
filling the joints with fine sand etc. all complete as per the direction of
Engineer-in-charge.(P.No-62, I.No-9.25, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Sqm | 1057.3 | 1057.3 | 76.27 | False | None | None | False | None | False | 80640.271 | 0 | 3849223 | 146987 | None | 8.35.2 | Painting with Silicon & Acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No-47, I.No-8.35.2, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Sqm | 261.7 | 261.7 | 146.51 | False | None | None | False | None | False | 38341.667 | 0 | 3849224 | 146987 | None | 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No-46, I.No-8.32, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Sqm | 206.1 | 206.1 | 175.07 | False | None | None | False | None | False | 36081.927 | 0 | 3849225 | 146987 | None | 8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No-48, I.No-8.41, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Sqm | 220.7 | 220.7 | 41.4 | False | None | None | False | None | False | 9136.98 | 0 | 3849226 | 146987 | None | 13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes.(P.No-123, I.No-13.33.5, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 630.4 | 630.4 | 18.0 | False | None | None | False | None | False | 11347.2 | 0 | 3849227 | 146987 | None | 13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes(P.No-123, I.No-13.33.3, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 391.2 | 391.2 | 24.0 | False | None | None | False | None | False | 9388.8 | 0 | 3849228 | 146987 | None | 13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore(P.No-119, I.No-13.12, PWD SR VOL-2 2023-24) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 403.1 | 403.1 | 2.0 | False | None | None | False | None | False | 806.2 | 0 | 3849229 | 146987 | None | 1.3.2 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 104.41 | 104.41 | 30.0 | False | None | None | False | None | False | 3132.3 | 0 | 3849230 | 146987 | None | 1.1.1 | Supplying heavy gauge PVC conduit pipe …….dia .mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrica ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 91.19 | 91.19 | 30.0 | False | None | None | False | None | False | 2735.7 | 0 | 3849231 | 146987 | None | 1.5.2 | Supplying and fixing PVC/metal conduit Deep junction box.( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 74.01 | 74.01 | 20.0 | False | None | None | False | None | False | 1480.2 | 0 | 3849232 | 146987 | None | 5.19.11 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.( COMMON SR of 2023-24 PWD ,PART -III Utilization ( PWD Electrical ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 5336.62 | 5336.62 | 2.0 | False | None | None | False | None | False | 10673.24 | 0 | 3849233 | 146987 | None | 3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.( COMMON SR of 2023-24 PWD ,PART - III Utilization (PWD Electrical ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 182.38 | 182.38 | 8.0 | False | None | None | False | None | False | 1459.04 | 0 | 3849234 | 146987 | None | 3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.( COMMON SR of 2023-24 PWD ,PART - III Utilization (PWD Electrical) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 233.92 | 233.92 | 4.0 | False | None | None | False | None | False | 935.68 | 0 | 3849235 | 146987 | None | 3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.( COMMON SR of 2023-24 PWD ,PART - III Utilization (PWD Electrical) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 290.75 | 290.75 | 2.0 | False | None | None | False | None | False | 581.5 | 0 | 3849236 | 146987 | None | 3.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 181.06 | 181.06 | 8.0 | False | None | None | False | None | False | 1448.48 | 0 | 3849237 | 146987 | None | 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 231.28 | 231.28 | 4.0 | False | None | None | False | None | False | 925.12 | 0 | 3849238 | 146987 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 309.25 | 309.25 | 2.0 | False | None | None | False | None | False | 618.5 | 0 | 3849239 | 146987 | None | 2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Point | 355.51 | 355.51 | 6.0 | False | None | None | False | None | False | 2133.06 | 0 | 3849240 | 146987 | None | 2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical )
Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch box ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Point | 500.89 | 500.89 | 6.0 | False | None | None | False | None | False | 3005.34 | 0 | 3849241 | 146987 | None | 2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical ) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Point | 733.49 | 733.49 | 4.0 | False | None | None | False | None | False | 2933.96 | 0 | 3849242 | 146987 | None | 3.6 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 .( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical )
6Amps one way. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 134.8 | 134.8 | 12.0 | False | None | None | False | None | False | 1617.6 | 0 | 3849243 | 146987 | None | 3.6.2 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 .( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 219.39 | 219.39 | 12.0 | False | None | None | False | None | False | 2632.68 | 0 | 3849244 | 146987 | None | 3.6.3 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 .( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 225.99 | 225.99 | 4.0 | False | None | None | False | None | False | 903.96 | 0 | 3849245 | 146987 | None | 3.6.9 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 .( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 430.84 | 430.84 | 2.0 | False | None | None | False | None | False | 861.68 | 0 | 3849246 | 146987 | None | 3.6.10 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 .( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 311.9 | 311.9 | 2.0 | False | None | None | False | None | False | 623.8 | 0 | 3849247 | 146987 | None | 2.3 | Wiring for lighting/power circuit using one of FR PVC insulated 1100V grade, multistrand Copper conductor single core cable in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP of GROUP -A. .( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical )
1.5mm2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 34.36 | 34.36 | 300.0 | False | None | None | False | None | False | 10308.0 | 0 | 3849248 | 146987 | None | 2.3.3 | Wiring for lighting/power circuit using one of FR PVC insulated 1100V grade, multistrand Copper conductor single core cable in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP of GROUP -A. .( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 55.51 | 55.51 | 120.0 | False | None | None | False | None | False | 6661.2 | 0 | 3849249 | 146987 | None | 2.3.4 | Wiring for lighting/power circuit using one of FR PVC insulated 1100V grade, multistrand Copper conductor single core cable in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP of GROUP -A. .( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical )
4mm2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 83.26 | 83.26 | 60.0 | False | None | None | False | None | False | 4995.6 | 0 | 3849250 | 146987 | None | 11.5 | Supply of round/square recess/surface mounted rolling type LED Down light with . W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greaterthan 80. Power Input: 220-240V @50/60Hz & Power factor greater than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 1749.8 | 1749.8 | 2.0 | False | None | None | False | None | False | 3499.6 | 0 | 3849251 | 146987 | None | 11.3 | Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power 20-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical)LED light fitting 1 x 4' - 20/22 W ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 911.9 | 911.9 | 8.0 | False | None | None | False | None | False | 7295.2 | 0 | 3849252 | 146987 | None | 11.11 | Supplying & fixing of retrofit type - LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy greater than 80 lumen per W, life greaterthan25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PFgreater 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Each | 203.53 | 203.53 | 8.0 | False | None | None | False | None | False | 1628.24 | 0 | 3849253 | 146987 | None | 12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | No | 5624.73 | 5624.73 | 2.0 | False | None | None | False | None | False | 11249.46 | 0 | 3849254 | 146987 | None | 12.58 | GI/Copper strips for grounding connections, using necessary fixing materials as required.( COMMON SR of 2023-24 PWD ,PART - III Utilization ( PWD Electrical ) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work. | Mtr | 108.37 | 108.37 | 30.0 | False | None | None | False | None | False | 3251.1 | 0 |
|