3844890 | 146735 | None | code01 | BUILDING CIVIL WORK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.-By Mechanical Means using Dozer-In area of thorny jungle. 100 Sqm | Sqm | 542.08 | 542.08 | 16.9 | False | None | None | False | None | False | 9161.152 | 0 |
3844891 | 146735 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m- | Cum | 114.24 | 114.24 | 3312.6 | False | None | None | False | None | False | 378431.424 | 0 |
3844892 | 146735 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth. | Cum | 406.56 | 406.56 | 414.08 | False | None | None | False | None | False | 168348.3648 | 0 |
3844893 | 146735 | None | code04 | Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m. | Cum | 271.04 | 271.04 | 414.08 | False | None | None | False | None | False | 112232.2432 | 0 |
3844894 | 146735 | None | code05 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 132.16 | 132.16 | 684.0 | False | None | None | False | None | False | 90397.44 | 0 |
3844895 | 146735 | None | code06 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. | Cum | 3003.84 | 3003.84 | 89.4654 | False | None | None | False | None | False | 268739.747136 | 0 |
3844896 | 146735 | None | code07 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates- | Cum | 6992.16 | 6992.16 | 78.19 | False | None | None | False | None | False | 546716.9904 | 0 |
3844897 | 146735 | None | code08 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-P-15 | Cum | 7664.03 | 7664.03 | 227.16 | False | None | None | False | None | False | 1740961.0548 | 0 |
3844898 | 146735 | None | code09 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- | Cum | 12063.74 | 12063.74 | 20.16 | False | None | None | False | None | False | 243204.9984 | 0 |
3844899 | 146735 | None | code10 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- | Cum | 8430.58 | 8430.58 | 97.31 | False | None | None | False | None | False | 820379.7398 | 0 |
3844900 | 146735 | None | code11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- | Cum | 11496.24 | 11496.24 | 20.19 | False | None | None | False | None | False | 232109.0856 | 0 |
3844901 | 146735 | None | code12 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.- | Cum | 297.92 | 297.92 | 937.46 | False | None | None | False | None | False | 279288.0832 | 0 |
3844902 | 146735 | None | code13 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work. | Cum | 95.2 | 95.2 | 3203.29 | False | None | None | False | None | False | 304953.208 | 0 |
3844903 | 146735 | None | code14 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)- | Cum | 7155.68 | 7155.68 | 40.05 | False | None | None | False | None | False | 286584.984 | 0 |
3844904 | 146735 | None | code15 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates- | Cum | 6992.16 | 6992.16 | 2.67 | False | None | None | False | None | False | 18669.0672 | 0 |
3844905 | 146735 | None | code16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates--LOWER GROUND FLOOR | Cum | 13029.07 | 13029.07 | 61.07 | False | None | None | False | None | False | 795685.3049 | 0 |
3844906 | 146735 | None | code17 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates--UPPER GROUND FLOOR | Cum | 13029.07 | 13029.07 | 38.48 | False | None | None | False | None | False | 501358.6136 | 0 |
3844907 | 146735 | None | code18 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates--FIRST FLOOR (BALCONY LEVEL) | Cum | 13159.36 | 13159.36 | 36.17 | False | None | None | False | None | False | 475974.0512 | 0 |
3844908 | 146735 | None | code19 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates--SECOND FLOOR | Cum | 13289.65 | 13289.65 | 27.45 | False | None | None | False | None | False | 364800.8925 | 0 |
3844909 | 146735 | None | code20 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates--TERRACE FLOOR | Cum | 13419.94 | 13419.94 | 6.93 | False | None | None | False | None | False | 93000.1842 | 0 |
3844910 | 146735 | None | code21 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates--TERRACE FLOOR | Cum | 12192.28 | 12192.28 | 11.66 | False | None | None | False | None | False | 142161.9848 | 0 |
3844911 | 146735 | None | code22 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC LINTEL--LOWER GROUND FLOOR | Cum | 12262.66 | 12262.66 | 0.31 | False | None | None | False | None | False | 3801.4246 | 0 |
3844912 | 146735 | None | code23 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC LINTEL--UPPER GROUND FLOOR | Cum | 12262.66 | 12262.66 | 7.61 | False | None | None | False | None | False | 93318.8426 | 0 |
3844913 | 146735 | None | code24 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC LINTEL--FIRST FLOOR (BALCONY LEVEL) | Cum | 12385.28 | 12385.28 | 6.16 | False | None | None | False | None | False | 76293.3248 | 0 |
3844914 | 146735 | None | code25 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC LINTEL--SECOND FLOOR | Cum | 12507.91 | 12507.91 | 4.4 | False | None | None | False | None | False | 55034.804 | 0 |
3844915 | 146735 | None | code26 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC LINTEL--TERRACE FLOOR | Cum | 12630.54 | 12630.54 | 1.1 | False | None | None | False | None | False | 13893.594 | 0 |
3844916 | 146735 | None | code27 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-LOWER GROUND FLOOR | Cum | 10138.63 | 10138.63 | 0.31 | False | None | None | False | None | False | 3142.9753 | 0 |
3844917 | 146735 | None | code28 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-UPPER GROUND FLOOR | Cum | 10138.63 | 10138.63 | 3.81 | False | None | None | False | None | False | 38628.1803 | 0 |
3844918 | 146735 | None | code29 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-FIRST FLOOR (BALCONY LEVEL) | Cum | 10240.02 | 10240.02 | 3.08 | False | None | None | False | None | False | 31539.2616 | 0 |
3844919 | 146735 | None | code30 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-SECOND FLOOR | Cum | 10341.4 | 10341.4 | 2.2 | False | None | None | False | None | False | 22751.08 | 0 |
3844920 | 146735 | None | code31 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-TERRACE FLOOR | Cum | 10442.79 | 10442.79 | 0.55 | False | None | None | False | None | False | 5743.5345 | 0 |
3844921 | 146735 | None | code32 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC STAIRCASE-LOWER GROUND FLOOR | Cum | 11496.24 | 11496.24 | 4.45 | False | None | None | False | None | False | 51158.268 | 0 |
3844922 | 146735 | None | code33 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC STAIRCASE-UPPER GROUND FLOOR | Cum | 11496.24 | 11496.24 | 19.09 | False | None | None | False | None | False | 219463.2216 | 0 |
3844923 | 146735 | None | code34 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC STAIRCASE-FIRST FLOOR(BALCONY LEVEL) | Cum | 11611.2 | 11611.2 | 9.34 | False | None | None | False | None | False | 108448.608 | 0 |
3844924 | 146735 | None | code35 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC STAIRCASE-SECOND FLOOR | Cum | 11726.16 | 11726.16 | 4.45 | False | None | None | False | None | False | 52181.412 | 0 |
3844925 | 146735 | None | code36 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC BEAM-LOWER GROUND FLOOR | Cum | 12262.66 | 12262.66 | 57.66 | False | None | None | False | None | False | 707064.9756 | 0 |
3844926 | 146735 | None | code37 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC BEAM-UPPER GROUND FLOOR | Cum | 12262.66 | 12262.66 | 41.51 | False | None | None | False | None | False | 509023.0166 | 0 |
3844927 | 146735 | None | code38 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC BEAM-FIRST FLOOR (BALCONY LEVEL) | Cum | 12385.28 | 12385.28 | 38.87 | False | None | None | False | None | False | 481415.8336 | 0 |
3844928 | 146735 | None | code39 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC BEAM-SECOND FLOOR | Cum | 12507.91 | 12507.91 | 46.85 | False | None | None | False | None | False | 585995.5835 | 0 |
3844929 | 146735 | None | code40 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC BEAM-TERRACE FLOOR | Cum | 12630.54 | 12630.54 | 4.06 | False | None | None | False | None | False | 51279.9924 | 0 |
3844930 | 146735 | None | code41 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC SLAB-LOWER GROUND FLOOR | Cum | 11496.24 | 11496.24 | 89.6 | False | None | None | False | None | False | 1030063.104 | 0 |
3844931 | 146735 | None | code42 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC SLAB--UPPER GROUND FLOOR | Cum | 11496.24 | 11496.24 | 63.55 | False | None | None | False | None | False | 730586.052 | 0 |
3844932 | 146735 | None | code43 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC SLAB--FIRST FLOOR(BALCONY LEVEL) | Cum | 11611.2 | 11611.2 | 52.3 | False | None | None | False | None | False | 607265.76 | 0 |
3844933 | 146735 | None | code44 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC SLAB--SECOND FLOOR | Cum | 11726.16 | 11726.16 | 11.89 | False | None | None | False | None | False | 139424.0424 | 0 |
3844934 | 146735 | None | code45 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC SLAB--TERRACE FLOOR | Cum | 11841.13 | 11841.13 | 6.0 | False | None | None | False | None | False | 71046.78 | 0 |
3844935 | 146735 | None | code46 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC CHAJJA-GROUND FLOOR | Cum | 11113.03 | 11113.03 | 4.22 | False | None | None | False | None | False | 46896.9866 | 0 |
3844936 | 146735 | None | code47 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC CHAJJA-FIRST FLOOR(BALCONY LEVEL) | Cum | 11224.16 | 11224.16 | 2.53 | False | None | None | False | None | False | 28397.1248 | 0 |
3844937 | 146735 | None | code48 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC CHAJJA-SECOND FLOOR | Cum | 11335.29 | 11335.29 | 3.85 | False | None | None | False | None | False | 43640.8665 | 0 |
3844938 | 146735 | None | code49 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.-GROUND FLOOR | Sqm | 1386.56 | 1386.56 | 4.22 | False | None | None | False | None | False | 5851.2832 | 0 |
3844939 | 146735 | None | code50 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.-FIRST FLOOR | Sqm | 1400.43 | 1400.43 | 2.53 | False | None | None | False | None | False | 3543.0879 | 0 |
3844940 | 146735 | None | code51 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.-SECOND FLOOR | Sqm | 1414.29 | 1414.29 | 3.85 | False | None | None | False | None | False | 5445.0165 | 0 |
3844941 | 146735 | None | code52 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a) Buildings- | Tonne | 100191.84 | 100191.84 | 125.19 | False | None | None | False | None | False | 12543016.4496 | 0 |
3844942 | 146735 | None | code53 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.-UPPER GROUND | Cum | 2259.04 | 2259.04 | 63.88 | False | None | None | False | None | False | 144307.4752 | 0 |
3844943 | 146735 | None | code54 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.-FIRST FLOOR(BALCONY LEVEL) | Cum | 2281.63 | 2281.63 | 32.2 | False | None | None | False | None | False | 73468.486 | 0 |
3844944 | 146735 | None | code55 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.-SECOND FLOOR | Cum | 2304.22 | 2304.22 | 5.63 | False | None | None | False | None | False | 12972.7586 | 0 |
3844945 | 146735 | None | code56 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates-UPPER GROUND | Cum | 6963.04 | 6963.04 | 23.95 | False | None | None | False | None | False | 166764.808 | 0 |
3844946 | 146735 | None | code57 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates-FIRST FLOOR(BALCONY LEVEL) | Cum | 7032.67 | 7032.67 | 12.07 | False | None | None | False | None | False | 84884.3269 | 0 |
3844947 | 146735 | None | code58 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates-SECOND FLOOR | Cum | 7102.3 | 7102.3 | 2.11 | False | None | None | False | None | False | 14985.853 | 0 |
3844948 | 146735 | None | code59 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-UPPER GROUND | Sqm | 415.52 | 415.52 | 16.22 | False | None | None | False | None | False | 6739.7344 | 0 |
3844949 | 146735 | None | code60 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-FIRST FLOOR(BALCONY LEVEL) | Sqm | 419.68 | 419.68 | 160.99 | False | None | None | False | None | False | 67564.2832 | 0 |
3844950 | 146735 | None | code61 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-SECOND FLOOR | Sqm | 423.83 | 423.83 | 28.17 | False | None | None | False | None | False | 11939.2911 | 0 |
3844951 | 146735 | None | code62 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.-LOWER GROUND FLOOR | Cum | 7565.6 | 7565.6 | 4.89 | False | None | None | False | None | False | 36995.784 | 0 |
3844952 | 146735 | None | code63 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.--UPPER GROUND FLOOR | Cum | 7565.6 | 7565.6 | 137.07 | False | None | None | False | None | False | 1037016.792 | 0 |
3844953 | 146735 | None | code64 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.--FIRST FLOOR(BALCONY LEVEL) | Cum | 7641.26 | 7641.26 | 104.95 | False | None | None | False | None | False | 801950.237 | 0 |
3844954 | 146735 | None | code65 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.--SECOND FLOOR | Cum | 7716.91 | 7716.91 | 104.95 | False | None | None | False | None | False | 809889.7045 | 0 |
3844955 | 146735 | None | code66 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.--TERRACE FLOOR | Cum | 7792.57 | 7792.57 | 20.87 | False | None | None | False | None | False | 162630.9359 | 0 |
3844956 | 146735 | None | code67 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.GROUND FLOOR | Sqm | 1467.2 | 1467.2 | 63.9 | False | None | None | False | None | False | 93754.08 | 0 |
3844957 | 146735 | None | code68 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-FIRST FLOOR(BALCONY LEVEL) | Sqm | 1481.87 | 1481.87 | 63.9 | False | None | None | False | None | False | 94691.493 | 0 |
3844958 | 146735 | None | code69 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-SECOND FLOOR | Sqm | 1496.54 | 1496.54 | 41.4 | False | None | None | False | None | False | 61956.756 | 0 |
3844959 | 146735 | None | code70 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.TERRACE FLOOR | Sqm | 1511.22 | 1511.22 | 30.9 | False | None | None | False | None | False | 46696.698 | 0 |
3844960 | 146735 | None | code71 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.--GROUND FLOOR | Sqm | 1378.72 | 1378.72 | 38.82 | False | None | None | False | None | False | 53521.9104 | 0 |
3844961 | 146735 | None | code72 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-FIRST FLOOR (BALCONY LEVEL) | Sqm | 1392.51 | 1392.51 | 31.95 | False | None | None | False | None | False | 44490.6945 | 0 |
3844962 | 146735 | None | code73 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-SECOND FLOOR | Sqm | 1406.29 | 1406.29 | 23.52 | False | None | None | False | None | False | 33075.9408 | 0 |
3844963 | 146735 | None | code74 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-TERRACE FLOOR | Sqm | 1420.08 | 1420.08 | 23.52 | False | None | None | False | None | False | 33400.2816 | 0 |
3844964 | 146735 | None | code75 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.--GROUND FLOOR | Sqm | 1236.48 | 1236.48 | 67.47 | False | None | None | False | None | False | 83425.3056 | 0 |
3844965 | 146735 | None | code76 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.--FIRST FLOOR (BALCONY LEVEL) | Sqm | 1248.84 | 1248.84 | 50.13 | False | None | None | False | None | False | 62604.3492 | 0 |
3844966 | 146735 | None | code77 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.--SECOND FLOOR | Sqm | 1261.21 | 1261.21 | 2.35 | False | None | None | False | None | False | 2963.8435 | 0 |
3844967 | 146735 | None | code78 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.--TERRACE FLOOR | Sqm | 1273.57 | 1273.57 | 135.3 | False | None | None | False | None | False | 172314.021 | 0 |
3844968 | 146735 | None | code79 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per
specifications. Sl.No 12.11, Page No.99, Volume- II, GROUND FLOOR. | Cum | 154642.88 | 154642.88 | 0.98 | False | None | None | False | None | False | 151550.0224 | 0 |
3844969 | 146735 | None | code80 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications--LOWER GROUND FLOOR | Cum | 111552.0 | 111552.0 | 0.12 | False | None | None | False | None | False | 13386.24 | 0 |
3844970 | 146735 | None | code81 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications--UPPER GROUND FLOOR | Cum | 111552.0 | 111552.0 | 1.15 | False | None | None | False | None | False | 128284.8 | 0 |
3844971 | 146735 | None | code82 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications--FIRST FLOOR ( BALCONY LEVEL) | Cum | 112667.52 | 112667.52 | 1.15 | False | None | None | False | None | False | 129567.648 | 0 |
3844972 | 146735 | None | code83 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications--SECOND FLOOR | Cum | 113783.04 | 113783.04 | 1.15 | False | None | None | False | None | False | 130850.496 | 0 |
3844973 | 146735 | None | code84 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications--TERRACE FLOOR | Cum | 114898.56 | 114898.56 | 0.1 | False | None | None | False | None | False | 11489.856 | 0 |
3844974 | 146735 | None | code85 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire
resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.UPPER GROUND FLOOR | m | 720.16 | 720.16 | 38.4 | False | None | None | False | None | False | 27654.144 | 0 |
3844975 | 146735 | None | code86 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire
resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.FIRST FLOOR (BALCONY LEVEL) | m | 727.36 | 727.36 | 32.0 | False | None | None | False | None | False | 23275.52 | 0 |
3844976 | 146735 | None | code87 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire
resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.-SECOND FLOOR | m | 734.56 | 734.56 | 6.4 | False | None | None | False | None | False | 4701.184 | 0 |
3844977 | 146735 | None | code88 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with
Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded
Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-LOWER GROUND FLOOR | Sqm | 7542.08 | 7542.08 | 3.6 | False | None | None | False | None | False | 27151.488 | 0 |
3844978 | 146735 | None | code89 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with
Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded
Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-UPPER GROUND FLOOR | Sqm | 7542.08 | 7542.08 | 93.42 | False | None | None | False | None | False | 704581.1136 | 0 |
3844979 | 146735 | None | code90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with
Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded
Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-FIRST FLOOR (BALCONY LEVEL) | Sqm | 7617.5 | 7617.5 | 71.82 | False | None | None | False | None | False | 547088.85 | 0 |
3844980 | 146735 | None | code91 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with
Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded
Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-SECOND FLOOR | Sqm | 7692.92 | 7692.92 | 18.9 | False | None | None | False | None | False | 145396.188 | 0 |
3844981 | 146735 | None | code92 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with
Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded
Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOOR | Sqm | 7768.34 | 7768.34 | 2.43 | False | None | None | False | None | False | 18877.0662 | 0 |
3844982 | 146735 | None | code93 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- -LOER GROUND | Sqm | 6405.28 | 6405.28 | 13.05 | False | None | None | False | None | False | 83588.904 | 0 |
3844983 | 146735 | None | code94 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- -UPPER GROUND FLOOR | Sqm | 6405.28 | 6405.28 | 13.05 | False | None | None | False | None | False | 83588.904 | 0 |
3844984 | 146735 | None | code95 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- -FIRST FLOOR (BALCONY LEVEL) | Sqm | 6469.33 | 6469.33 | 5.13 | False | None | None | False | None | False | 33187.6629 | 0 |
3844985 | 146735 | None | code96 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- SECOND FLOOR | Sqm | 6533.39 | 6533.39 | 2.97 | False | None | None | False | None | False | 19404.1683 | 0 |
3844986 | 146735 | None | code97 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.-UPPER GROUND FLOOR | Sqm | 8906.24 | 8906.24 | 6.0 | False | None | None | False | None | False | 53437.44 | 0 |
3844987 | 146735 | None | code98 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.\FIRST FLOOR(BALCONYLEVEL) | Sqm | 8995.3 | 8995.3 | 6.0 | False | None | None | False | None | False | 53971.8 | 0 |
3844988 | 146735 | None | code99 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.SECOND FLOOR | Sqm | 9084.36 | 9084.36 | 6.0 | False | None | None | False | None | False | 54506.16 | 0 |
3844989 | 146735 | None | code100 | Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) Sl. No. 12.20
Page No. 100,
Volume-II -UPPER GROUND FLOOR | Sqm | 6888.0 | 6888.0 | 13.23 | False | None | None | False | None | False | 91128.24 | 0 |
3844990 | 146735 | None | code101 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial-LOWER GROUND FLOOR | Sqm | 3720.64 | 3720.64 | 2.57 | False | None | None | False | None | False | 9562.0448 | 0 |
3844991 | 146735 | None | code102 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial-UPPER GROUND FLOOR | Sqm | 3720.64 | 3720.64 | 24.82 | False | None | None | False | None | False | 92346.2848 | 0 |
3844992 | 146735 | None | code103 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercialFIRST FLOOR (BALCONY LEVEL) | Sqm | 3757.85 | 3757.85 | 8.13 | False | None | None | False | None | False | 30551.3205 | 0 |
3844993 | 146735 | None | code104 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial-SECOND FLOOR | Sqm | 3795.05 | 3795.05 | 5.15 | False | None | None | False | None | False | 19544.5075 | 0 |
3844994 | 146735 | None | code105 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial-TERRACE FLOOR | Sqm | 3832.26 | 3832.26 | 2.94 | False | None | None | False | None | False | 11266.8444 | 0 |
3844995 | 146735 | None | code106 | Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.- 30 mm thickness--UPPER GROUND FLOOR | Sqm | 3588.48 | 3588.48 | 9.68 | False | None | None | False | None | False | 34736.4864 | 0 |
3844996 | 146735 | None | code107 | Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.- 30 mm thickness-FIRST FLOOR (BALCONY LEVEL) | Sqm | 3624.36 | 3624.36 | 9.68 | False | None | None | False | None | False | 35083.8048 | 0 |
3844997 | 146735 | None | code108 | Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.- 30 mm thickness-SECOND FLOOR | Sqm | 3660.25 | 3660.25 | 3.23 | False | None | None | False | None | False | 11822.6075 | 0 |
3844998 | 146735 | None | code109 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge.TERRACE FLOOR | Sqm | 5165.82 | 5165.82 | 2.45 | False | None | None | False | None | False | 12656.259 | 0 |
3844999 | 146735 | None | code110 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.-GROUND FLOOR | Nos | 1137.92 | 1137.92 | 9.0 | False | None | None | False | None | False | 10241.28 | 0 |
3845000 | 146735 | None | code111 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.--SECOND FLOOR | Nos | 1149.3 | 1149.3 | 12.0 | False | None | None | False | None | False | 13791.6 | 0 |
3845001 | 146735 | None | code112 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.-SECOND FLOOR | Nos | 1160.68 | 1160.68 | 11.0 | False | None | None | False | None | False | 12767.48 | 0 |
3845002 | 146735 | None | code113 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.--TERRACE FLOOR | Nos | 1172.06 | 1172.06 | 1.0 | False | None | None | False | None | False | 1172.06 | 0 |
3845003 | 146735 | None | code114 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Nos | 134.4 | 134.4 | 66.0 | False | None | None | False | None | False | 8870.4 | 0 |
3845004 | 146735 | None | code115 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete- | Nos | 1178.24 | 1178.24 | 66.0 | False | None | None | False | None | False | 77763.84 | 0 |
3845005 | 146735 | None | code116 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete- | Nos | 265.44 | 265.44 | 66.0 | False | None | None | False | None | False | 17519.04 | 0 |
3845006 | 146735 | None | code117 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm, | Nos | 487.2 | 487.2 | 66.0 | False | None | None | False | None | False | 32155.2 | 0 |
3845007 | 146735 | None | code118 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :-125x85x5.5mm.(heavy type) Sl.no-12.75.1, pg.no-107,volume-2. | Nos | 308.0 | 308.0 | 496.0 | False | None | None | False | None | False | 152768.0 | 0 |
3845008 | 146735 | None | code119 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :-100x85x5.5mm.(heavy type) Sl.no-12.75.3, pg.no-107,volume-2. | Nos | 229.6 | 229.6 | 81.0 | False | None | None | False | None | False | 18597.6 | 0 |
3845009 | 146735 | None | code120 | Providing and fixing MS Hold fasts (SL. No 444,Page No.A-25, Basic Rate Rs. 50.00), volume-2. | Each | 56.0 | 56.0 | 198.0 | False | None | None | False | None | False | 11088.0 | 0 |
3845010 | 146735 | None | code121 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms-SL.NO-12.64, PG.NO-105,VOLUME-2. | Nos | 61.6 | 61.6 | 60.0 | False | None | None | False | None | False | 3696.0 | 0 |
3845011 | 146735 | None | code122 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding,-LOWER GROUND FLOOR | Kg | 188.16 | 188.16 | 64.8 | False | None | None | False | None | False | 12192.768 | 0 |
3845012 | 146735 | None | code123 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding,-UPPER GROUND FLOOR | Kg | 188.16 | 188.16 | 1681.56 | False | None | None | False | None | False | 316402.3296 | 0 |
3845013 | 146735 | None | code124 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding,-FIRST FLOOR (BALCONY LEVEL) | Kg | 190.04 | 190.04 | 1292.76 | False | None | None | False | None | False | 245676.1104 | 0 |
3845014 | 146735 | None | code125 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding,-SECOND FLOOR | Kg | 191.92 | 191.92 | 340.2 | False | None | None | False | None | False | 65291.184 | 0 |
3845015 | 146735 | None | code126 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding,-TERRACE FLOOR | Kg | 193.8 | 193.8 | 291.6 | False | None | None | False | None | False | 56512.08 | 0 |
3845016 | 146735 | None | code127 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of EngineerIn-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.LOWER GROUND FLOOR | Sqm | 361.76 | 361.76 | 597.36 | False | None | None | False | None | False | 216100.9536 | 0 |
3845017 | 146735 | None | code128 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-UPPER GROUND FLOOR | Sqm | 361.76 | 361.76 | 732.36 | False | None | None | False | None | False | 264938.5536 | 0 |
3845018 | 146735 | None | code129 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-FIRST FLOOR (BALCONY LEVEL) | Sqm | 365.38 | 365.38 | 1056.1 | False | None | None | False | None | False | 385877.818 | 0 |
3845019 | 146735 | None | code130 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-SECOND FLOOR | Sqm | 369.0 | 369.0 | 402.5 | False | None | None | False | None | False | 148522.5 | 0 |
3845020 | 146735 | None | code131 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-TERRACE FLOOR | Sqm | 372.61 | 372.61 | 57.55 | False | None | None | False | None | False | 21443.7055 | 0 |
3845021 | 146735 | None | code132 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-LOWER GROUND FLOOR | Sqm | 361.76 | 361.76 | 119.47 | False | None | None | False | None | False | 43219.4672 | 0 |
3845022 | 146735 | None | code133 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-UPPER GROUND FLOOR | Sqm | 361.76 | 361.76 | 146.47 | False | None | None | False | None | False | 52986.9872 | 0 |
3845023 | 146735 | None | code134 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-FIRST FLOOR (BALCONY LEVEL) | Sqm | 365.38 | 365.38 | 211.22 | False | None | None | False | None | False | 77175.5636 | 0 |
3845024 | 146735 | None | code135 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-SECOND FLOOR | Sqm | 369.0 | 369.0 | 80.5 | False | None | None | False | None | False | 29704.5 | 0 |
3845025 | 146735 | None | code136 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-TERRACE FLOOR | Sqm | 372.61 | 372.61 | 11.51 | False | None | None | False | None | False | 4288.7411 | 0 |
3845026 | 146735 | None | code137 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide-LOWER GROUND FLOOR | Sqm | 42.56 | 42.56 | 477.89 | False | None | None | False | None | False | 20338.9984 | 0 |
3845027 | 146735 | None | code138 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide-UPPER GROUND FLOOR | Sqm | 42.56 | 42.56 | 585.89 | False | None | None | False | None | False | 24935.4784 | 0 |
3845028 | 146735 | None | code139 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide-FIRST FLOOR (BALCONY LEVEL) | Sqm | 42.99 | 42.99 | 844.88 | False | None | None | False | None | False | 36321.3912 | 0 |
3845029 | 146735 | None | code140 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide-SECOND FLOOR | Sqm | 43.41 | 43.41 | 322.0 | False | None | None | False | None | False | 13978.02 | 0 |
3845030 | 146735 | None | code141 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide-TERRACE FLOOR | Sqm | 43.84 | 43.84 | 46.04 | False | None | None | False | None | False | 2018.3936 | 0 |
3845031 | 146735 | None | code142 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2.-LOWER GROUND FLOOR | Sqm | 409.92 | 409.92 | 493.63 | False | None | None | False | None | False | 202348.8096 | 0 |
3845032 | 146735 | None | code143 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2.UPPER GROUND FLOOR | Sqm | 409.92 | 409.92 | 994.67 | False | None | None | False | None | False | 407735.1264 | 0 |
3845033 | 146735 | None | code144 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2.-FIRST FLOOR (BALCONY LEVEL) | Sqm | 414.02 | 414.02 | 1008.36 | False | None | None | False | None | False | 417481.2072 | 0 |
3845034 | 146735 | None | code145 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2.-SECOND FLOOR | Sqm | 418.12 | 418.12 | 951.62 | False | None | None | False | None | False | 397891.3544 | 0 |
3845035 | 146735 | None | code146 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2.-TERRACE FLOOR | Sqm | 422.22 | 422.22 | 68.9 | False | None | None | False | None | False | 29090.958 | 0 |
3845036 | 146735 | None | code147 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41, Volume- 2.-UPPER GROUND FLOOR | Sqm | 330.4 | 330.4 | 156.84 | False | None | None | False | None | False | 51819.936 | 0 |
3845037 | 146735 | None | code148 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41, Volume- 2.-FIRST FLOOR (BALCONY LEVEL) | Sqm | 333.7 | 333.7 | 106.77 | False | None | None | False | None | False | 35629.149 | 0 |
3845038 | 146735 | None | code149 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41, Volume- 2.-SECOND FLOOR | Sqm | 337.01 | 337.01 | 16.08 | False | None | None | False | None | False | 5419.1208 | 0 |
3845039 | 146735 | None | code150 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.-LOWER GROUND FLOOR | Sqm | 431.2 | 431.2 | 499.5 | False | None | None | False | None | False | 215384.4 | 0 |
3845040 | 146735 | None | code151 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.-UPPER GROUND FLOOR | Sqm | 431.2 | 431.2 | 545.0 | False | None | None | False | None | False | 235004.0 | 0 |
3845041 | 146735 | None | code152 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.FIRST FLOOR (BALCONY LEVEL) | Sqm | 435.51 | 435.51 | 548.5 | False | None | None | False | None | False | 238877.235 | 0 |
3845042 | 146735 | None | code153 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.-SECOND FLOOR | Sqm | 439.82 | 439.82 | 514.2 | False | None | None | False | None | False | 226155.444 | 0 |
3845043 | 146735 | None | code154 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.-TERRACE FLOOR | Sqm | 444.14 | 444.14 | 343.0 | False | None | None | False | None | False | 152340.02 | 0 |
3845044 | 146735 | None | code155 | Providing ruled pointing to coursed stone masonry with lime mortar 1:3, 20mm deep, after raking joints to depth of 20mm nicely lining, including cost all materials, labour, usage charges of machinery, curing complete as per specification.-GROUND FLOOR | Sqm | 334.88 | 334.88 | 121.0 | False | None | None | False | None | False | 40520.48 | 0 |
3845045 | 146735 | None | code156 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-Page 15, Sl. No.2.1.6, Volume-I-LOWER GROUND FLOOR | Cum | 6992.16 | 6992.16 | 69.5 | False | None | None | False | None | False | 485955.12 | 0 |
3845046 | 146735 | None | code157 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the
Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.-GROUND FLOOR | Sqm | 3194.24 | 3194.24 | 666.43 | False | None | None | False | None | False | 2128737.3632 | 0 |
3845047 | 146735 | None | code158 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the
Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.-FIRST FLOOR (BALCONY LEVEL) | Sqm | 3226.18 | 3226.18 | 287.91 | False | None | None | False | None | False | 928849.4838 | 0 |
3845048 | 146735 | None | code159 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the
Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.SECOND FLOOR | Sqm | 3258.12 | 3258.12 | 134.79 | False | None | None | False | None | False | 439161.9948 | 0 |
3845049 | 146735 | None | code160 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.LOWER GROUND FLOOR | Sqm | 5967.36 | 5967.36 | 30.69 | False | None | None | False | None | False | 183138.2784 | 0 |
3845050 | 146735 | None | code161 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.-UPPER GROUND FLOOR | Sqm | 5967.36 | 5967.36 | 100.6 | False | None | None | False | None | False | 600316.416 | 0 |
3845051 | 146735 | None | code162 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.-FIRST FLOOR (BALCONY LEVEL) | Sqm | 6027.03 | 6027.03 | 57.29 | False | None | None | False | None | False | 345288.5487 | 0 |
3845052 | 146735 | None | code163 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete-GROUND FLOOR | Sqm | 3762.08 | 3762.08 | 58.5 | False | None | None | False | None | False | 220081.68 | 0 |
3845053 | 146735 | None | code164 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete-FIRST FLOOR | Sqm | 3799.7 | 3799.7 | 45.0 | False | None | None | False | None | False | 170986.5 | 0 |
3845054 | 146735 | None | code165 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., completeSECOND FLOOR | Sqm | 3837.32 | 3837.32 | 45.0 | False | None | None | False | None | False | 172679.4 | 0 |
3845055 | 146735 | None | code166 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..-- Size of Tile 600x600 mm-LOWER GROUND FLOOR | Sqm | 1282.4 | 1282.4 | 6.36 | False | None | None | False | None | False | 8156.064 | 0 |
3845056 | 146735 | None | code167 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..-- Size of Tile 600x600 mm-UPPER GROUND FLOOR | Sqm | 1282.4 | 1282.4 | 60.34 | False | None | None | False | None | False | 77380.016 | 0 |
3845057 | 146735 | None | code168 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..-- Size of Tile 600x600 mm-FIRST FLOOR (BALCONY LEVEL) | Sqm | 1295.22 | 1295.22 | 35.1 | False | None | None | False | None | False | 45462.222 | 0 |
3845058 | 146735 | None | code169 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..-- Size of Tile 600x600 mmSECOND FLOOR | Sqm | 1308.05 | 1308.05 | 66.15 | False | None | None | False | None | False | 86527.5075 | 0 |
3845059 | 146735 | None | code170 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71, Volume-2.-UPPER GROUND FLOOR | Sqm | 1238.72 | 1238.72 | 156.84 | False | None | None | False | None | False | 194280.8448 | 0 |
3845060 | 146735 | None | code171 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71, Volume-2.-FIRST FLOOR | Sqm | 1251.11 | 1251.11 | 106.77 | False | None | None | False | None | False | 133581.0147 | 0 |
3845061 | 146735 | None | code172 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71, Volume-2.-SECOND FLOOR | Sqm | 1263.49 | 1263.49 | 16.08 | False | None | None | False | None | False | 20316.9192 | 0 |
3845062 | 146735 | None | code173 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.-UPPER GROUND FLOOR | Sqm | 1205.12 | 1205.12 | 19.34 | False | None | None | False | None | False | 23307.0208 | 0 |
3845063 | 146735 | None | code174 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.-FIRST FLOOR (BALCONY LEVEL) | Sqm | 1217.17 | 1217.17 | 22.74 | False | None | None | False | None | False | 27678.4458 | 0 |
3845064 | 146735 | None | code175 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.-SECOND FLOOR | Sqm | 1229.22 | 1229.22 | 3.47 | False | None | None | False | None | False | 4265.3934 | 0 |
3845065 | 146735 | None | code176 | Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.-UPPER GROUND FLOOR | Sqm | 4792.48 | 4792.48 | 10.1 | False | None | None | False | None | False | 48404.048 | 0 |
3845066 | 146735 | None | code177 | Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.-FIRST FLOOR (BALCONY LEVEL) | Sqm | 4840.4 | 4840.4 | 7.56 | False | None | None | False | None | False | 36593.424 | 0 |
3845067 | 146735 | None | code178 | Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.-SECOND FLOOR | Sqm | 4888.33 | 4888.33 | 1.2 | False | None | None | False | None | False | 5865.996 | 0 |
3845068 | 146735 | None | code179 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2..-UPPER GROUND FLOOR | Sqm | 112.0 | 112.0 | 1434.62 | False | None | None | False | None | False | 160677.44 | 0 |
3845069 | 146735 | None | code180 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2..-GROUND FLOOR | Sqm | 112.0 | 112.0 | 1873.5 | False | None | None | False | None | False | 209832.0 | 0 |
3845070 | 146735 | None | code181 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2..-FIRST FLOOR | Sqm | 113.12 | 113.12 | 2275.68 | False | None | None | False | None | False | 257424.9216 | 0 |
3845071 | 146735 | None | code182 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2..-SECOND FLOOR | Sqm | 114.24 | 114.24 | 1434.62 | False | None | None | False | None | False | 163890.9888 | 0 |
3845072 | 146735 | None | code183 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2..-TERRACE FLOOR | Sqm | 115.36 | 115.36 | 137.96 | False | None | None | False | None | False | 15915.0656 | 0 |
3845073 | 146735 | None | code184 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.-UPPER GROUND FLOOR | Sqm | 176.96 | 176.96 | 402.5 | False | None | None | False | None | False | 71226.4 | 0 |
3845074 | 146735 | None | code185 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.-GROUND FLOOR | Sqm | 176.96 | 176.96 | 732.36 | False | None | None | False | None | False | 129598.4256 | 0 |
3845075 | 146735 | None | code186 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.-FIRST FLOOR | Sqm | 178.73 | 178.73 | 1056.1 | False | None | None | False | None | False | 188756.753 | 0 |
3845076 | 146735 | None | code187 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.-SECOND FLOOR | Sqm | 180.5 | 180.5 | 402.5 | False | None | None | False | None | False | 72651.25 | 0 |
3845077 | 146735 | None | code188 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.-TERRACE FLOOR | Sqm | 182.27 | 182.27 | 57.55 | False | None | None | False | None | False | 10489.6385 | 0 |
3845078 | 146735 | None | code189 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)-UPPER GROUND FLOOR | Sqm | 176.96 | 176.96 | 951.62 | False | None | None | False | None | False | 168398.6752 | 0 |
3845079 | 146735 | None | code190 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)-GROUND FLOOR | Sqm | 176.96 | 176.96 | 994.67 | False | None | None | False | None | False | 176016.8032 | 0 |
3845080 | 146735 | None | code191 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)-FIRST FLOOR | Sqm | 178.73 | 178.73 | 1008.36 | False | None | None | False | None | False | 180224.1828 | 0 |
3845081 | 146735 | None | code192 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)-SECOND FLOOR | Sqm | 180.5 | 180.5 | 951.62 | False | None | None | False | None | False | 171767.41 | 0 |
3845082 | 146735 | None | code193 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)-TERRACE FLOOR | Sqm | 182.27 | 182.27 | 68.9 | False | None | None | False | None | False | 12558.403 | 0 |
3845083 | 146735 | None | code194 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-UPPER GROUND FLOOR | Sqm | 316.96 | 316.96 | 77.13 | False | None | None | False | None | False | 24447.1248 | 0 |
3845084 | 146735 | None | code195 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-GROUND FLOOR | Sqm | 316.96 | 316.96 | 81.75 | False | None | None | False | None | False | 25911.48 | 0 |
3845085 | 146735 | None | code196 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-FIRST FLOOR | Sqm | 320.13 | 320.13 | 82.28 | False | None | None | False | None | False | 26340.2964 | 0 |
3845086 | 146735 | None | code197 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-SECOND FLOOR | Sqm | 323.3 | 323.3 | 77.13 | False | None | None | False | None | False | 24936.129 | 0 |
3845087 | 146735 | None | code198 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-TERRACE FLOOR | Sqm | 326.47 | 326.47 | 34.3 | False | None | None | False | None | False | 11197.921 | 0 |
3845088 | 146735 | None | code199 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2.-UPPER GROUND FLOOR | Sqm | 194.88 | 194.88 | 411.36 | False | None | None | False | None | False | 80165.8368 | 0 |
3845089 | 146735 | None | code200 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2.-GROUND FLOOR | Sqm | 194.88 | 194.88 | 436.0 | False | None | None | False | None | False | 84967.68 | 0 |
3845090 | 146735 | None | code201 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2.-FIRST FLOOR | Sqm | 196.83 | 196.83 | 438.8 | False | None | None | False | None | False | 86369.004 | 0 |
3845091 | 146735 | None | code202 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2.-SECOND FLOOR | Sqm | 198.78 | 198.78 | 411.36 | False | None | None | False | None | False | 81770.1408 | 0 |
3845092 | 146735 | None | code203 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2.-TERRACE FLOOR | Sqm | 200.73 | 200.73 | 274.4 | False | None | None | False | None | False | 55080.312 | 0 |
3845093 | 146735 | None | code204 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2.-LOWER GROUND FLOOR | Sqm | 187.04 | 187.04 | 7.2 | False | None | None | False | None | False | 1346.688 | 0 |
3845094 | 146735 | None | code205 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2.-GROUND FLOOR | Sqm | 187.04 | 187.04 | 186.84 | False | None | None | False | None | False | 34946.5536 | 0 |
3845095 | 146735 | None | code206 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2.-FIRST FLOOR | Sqm | 188.91 | 188.91 | 143.64 | False | None | None | False | None | False | 27135.0324 | 0 |
3845096 | 146735 | None | code207 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2.-SECOND FLOOR | Sqm | 190.78 | 190.78 | 37.8 | False | None | None | False | None | False | 7211.484 | 0 |
3845097 | 146735 | None | code208 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2.-TERRACE FLOOR | Sqm | 192.65 | 192.65 | 6.08 | False | None | None | False | None | False | 1171.312 | 0 |
3845098 | 146735 | None | code209 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.50, Volume-2.-LOWER GROUND FLOOR | Sqm | 62.72 | 62.72 | 6.43 | False | None | None | False | None | False | 403.2896 | 0 |
3845099 | 146735 | None | code210 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.50, Volume-2.-GROUND FLOOR | Sqm | 62.72 | 62.72 | 95.12 | False | None | None | False | None | False | 5965.9264 | 0 |
3845100 | 146735 | None | code211 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.50, Volume-2.-FIRST FLOOR | Sqm | 63.35 | 63.35 | 20.34 | False | None | None | False | None | False | 1288.539 | 0 |
3845101 | 146735 | None | code212 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.50, Volume-2.-SECOND FLOOR | Sqm | 63.97 | 63.97 | 20.21 | False | None | None | False | None | False | 1292.8337 | 0 |
3845102 | 146735 | None | code213 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49,volume-2.-GROUND FLOOR | Sqm | 151.2 | 151.2 | 95.12 | False | None | None | False | None | False | 14382.144 | 0 |
3845103 | 146735 | None | code214 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49,volume-2.-FIRST FLOOR | Sqm | 152.71 | 152.71 | 20.34 | False | None | None | False | None | False | 3106.1214 | 0 |
3845104 | 146735 | None | code215 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49,volume-2.-SECOND FLOOR | Sqm | 154.22 | 154.22 | 20.21 | False | None | None | False | None | False | 3116.7862 | 0 |
3845105 | 146735 | None | code216 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sl.No 11.28, Page No.85, Volume-2.-LOWER GROUND FLOOR | Kg | 632.8 | 632.8 | 7.56 | False | None | None | False | None | False | 4783.968 | 0 |
3845106 | 146735 | None | code217 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sl.No 11.28, Page No.85, Volume-2.-UPPER GROUND FLOOR | Kg | 632.8 | 632.8 | 214.2 | False | None | None | False | None | False | 135545.76 | 0 |
3845107 | 146735 | None | code218 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sl.No 11.28, Page No.85, Volume-2.-FIRST FLOOR (BALCONY LEVEL) | Kg | 639.13 | 639.13 | 212.04 | False | None | None | False | None | False | 135521.1252 | 0 |
3845108 | 146735 | None | code219 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sl.No 11.28, Page No.85, Volume-2.-SECOND FLOOR | Kg | 645.46 | 645.46 | 45.36 | False | None | None | False | None | False | 29278.0656 | 0 |
3845109 | 146735 | None | code220 | Providing and fixing ion wall face unplasticised Rigid PVC rain water pipes confirming to IS :13592 Type A,including jointing with seal ring confirming to IS:5382,leaving 10mm gap for thermal expansion,(i) Single socketed pipes 100mm diameter.item no-13.48, volume-2. PG.NO-125. | m | 332.44 | 332.44 | 180.0 | False | None | None | False | None | False | 59839.2 | 0 |
3845110 | 146735 | None | code221 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge | Sqm | 896.0 | 896.0 | 184.25 | False | None | None | False | None | False | 165088.0 | 0 |
3845111 | 146735 | None | code222 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7102.3 | 7102.3 | 36.32 | False | None | None | False | None | False | 257955.536 | 0 |
3845112 | 146735 | None | code223 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification | Sqm | 915.04 | 915.04 | 396.0 | False | None | None | False | None | False | 362355.84 | 0 |
3845113 | 146735 | None | code224 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 9269.12 | 9269.12 | 7.5 | False | None | None | False | None | False | 69518.4 | 0 |
3845114 | 146735 | None | code225 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 602.59 | 602.59 | 562.46 | False | None | None | False | None | False | 338932.7714 | 0 |
3845115 | 146735 | None | code226 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top cover- | Sqm | 450.88 | 450.88 | 562.46 | False | None | None | False | None | False | 253601.9648 | 0 |
3845116 | 146735 | None | code227 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top cover | m | 1139.41 | 1139.41 | 26.04 | False | None | None | False | None | False | 29670.2364 | 0 |
3845117 | 146735 | None | code228 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top cover | m | 478.47 | 478.47 | 52.08 | False | None | None | False | None | False | 24918.7176 | 0 |
3845118 | 146735 | None | code229 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 154.44 | 154.44 | 5624.64 | False | None | None | False | None | False | 868669.4016 | 0 |
3845119 | 146735 | None | code230 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. | Sqm | 1743.79 | 1743.79 | 160.0 | False | None | None | False | None | False | 279006.4 | 0 |
3845120 | 146735 | None | code231 | PLUMBING AND SANITARY-Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. Sl.No 14.1.1, Page No.131, Volume-II | Nos | 5470.08 | 5470.08 | 10.0 | False | None | None | False | None | False | 54700.8 | 0 |
3845121 | 146735 | None | code232 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. Sl.No 14.3.1, Page No.131, Volume-II | Nos | 6694.24 | 6694.24 | 5.0 | False | None | None | False | None | False | 33471.2 | 0 |
3845122 | 146735 | None | code233 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. Sl.No 14.7A, Page No.133, Volume-II | Nos | 4615.52 | 4615.52 | 17.0 | False | None | None | False | None | False | 78463.84 | 0 |
3845123 | 146735 | None | code234 | Providing and fixing 100 mm sand cast Iron grating for gully trap. Sl.No 14.29, Page No.136, Volume-II. | Nos | 52.64 | 52.64 | 45.0 | False | None | None | False | None | False | 2368.8 | 0 |
3845124 | 146735 | None | code235 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. Sl.No 13.15, Page No.119, Volume-II | Nos | 812.0 | 812.0 | 50.0 | False | None | None | False | None | False | 40600.0 | 0 |
3845125 | 146735 | None | code236 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g. Sl.No 13.13, Page No.119, Volume-II | Nos | 947.52 | 947.52 | 50.0 | False | None | None | False | None | False | 47376.0 | 0 |
3845126 | 146735 | None | code237 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-25 mm nominal bore | Nos | 614.88 | 614.88 | 3.0 | False | None | None | False | None | False | 1844.64 | 0 |
3845127 | 146735 | None | code238 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-32 mm nominal bore | Nos | 669.76 | 669.76 | 3.0 | False | None | None | False | None | False | 2009.28 | 0 |
3845128 | 146735 | None | code239 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-40 mm nominal bore | Nos | 786.24 | 786.24 | 3.0 | False | None | None | False | None | False | 2358.72 | 0 |
3845129 | 146735 | None | code240 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-50 mm nominal bore | Nos | 957.6 | 957.6 | 3.0 | False | None | None | False | None | False | 2872.8 | 0 |
3845130 | 146735 | None | code241 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-65 mm nominal bore | Nos | 1277.92 | 1277.92 | 3.0 | False | None | None | False | None | False | 3833.76 | 0 |
3845131 | 146735 | None | code242 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-80 mm nominal bore | Nos | 2326.24 | 2326.24 | 2.0 | False | None | None | False | None | False | 4652.48 | 0 |
3845132 | 146735 | None | code243 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Sl.No 14.31, Page No.136, Volume-II | Nos | 1368.64 | 1368.64 | 15.0 | False | None | None | False | None | False | 20529.6 | 0 |
3845133 | 146735 | None | code244 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Sl.No 14.40.2, Page No.137, Volume-II | Nos | 555.52 | 555.52 | 15.0 | False | None | None | False | None | False | 8332.8 | 0 |
3845134 | 146735 | None | code245 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations
and cuts of pipes wherever necessary including jointing of PVC pipes
and specials (excluding cost of specials) with jointing of approved
type, with all labour with all lead & lift including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will make
his own arrangements for procuring water for testing) etc. complete For: PVC pipes 160mm dia., 6 kg/sqcm & class 3. Sl.No 10.1.9, PG.NO-113, VOLUME-5. | m | 692.16 | 692.16 | 110.0 | False | None | None | False | None | False | 76137.6 | 0 |
3845135 | 146735 | None | code246 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations
and cuts of pipes wherever necessary including jointing of PVC pipes
and specials (excluding cost of specials) with jointing of approved
type, with all labour with all lead & lift including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will make
his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia., 6 kg/sqcm & class 3. Sl.No 10.1.7, PG.NO-113, VOLUME-5. | m | 460.32 | 460.32 | 169.0 | False | None | None | False | None | False | 77794.08 | 0 |
3845136 | 146735 | None | code247 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations
and cuts of pipes wherever necessary including jointing of PVC pipes
and specials (excluding cost of specials) with jointing of approved
type, with all labour with all lead & lift including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will make
his own arrangements for procuring water for testing) etc. complete For: PVC pipes 90mm dia., 6 kg/sqcm & class 3. Sl.No 10.1.6, PG.NO-113, VOLUME-5. | m | 329.28 | 329.28 | 185.0 | False | None | None | False | None | False | 60916.8 | 0 |
3845137 | 146735 | None | code248 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge. Internal work - Exposed on wall - 50 mm nominal dia Pipes. Sl.No 13.31.6, PG.NO-122, VOL-2. | m | 874.72 | 874.72 | 105.0 | False | None | None | False | None | False | 91845.6 | 0 |
3845138 | 146735 | None | code249 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 32 mm dia. Sl.No 13.32.4, page-122, VOL-2. | m | 623.84 | 623.84 | 85.0 | False | None | None | False | None | False | 53026.4 | 0 |
3845139 | 146735 | None | code250 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 25 mm dia. Sl.No 13.32.3, page-122, VOL-2. | m | 534.24 | 534.24 | 200.0 | False | None | None | False | None | False | 106848.0 | 0 |
3845140 | 146735 | None | code251 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 20 mm dia. Sl.No 13.32.2, page-122, VOL-2. | Nos | 424.48 | 424.48 | 200.0 | False | None | None | False | None | False | 84896.0 | 0 |
3845141 | 146735 | None | code252 | Constructing brick masonry chamber of internal dimension 450x450mm
and depth of 600mm (inner dimensions) with modular bricks of CD 75
in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering
12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing
CI cover & frame etc. excluding the cost of CI frame and cover. Sl.No 16.10,page-191, VOL-5. | Nos | 4744.32 | 4744.32 | 10.0 | False | None | None | False | None | False | 47443.2 | 0 |
3845142 | 146735 | None | code253 | KSRB 11-18-9.1 : Providing and fixing sand cast iron soil waste single equal junction of required degree with access door 100x100x100mm, including cost of materials, labour, testing complete as per specifications. Specification No. KBS 11.1.10, | Nos | 1044.96 | 1044.96 | 20.0 | False | None | None | False | None | False | 20899.2 | 0 |
3845143 | 146735 | None | code254 | Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, IS : 12701 marked, with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank. Sl.No 13.34, page-123, VOL-2. | l | 10.08 | 10.08 | 5000.0 | False | None | None | False | None | False | 50400.0 | 0 |
3845144 | 146735 | None | code255 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch)
suitable for bore well confirming to IS 8034-2000 specifications, to work
site with testing of as per instructions of engineer incharge of work and latest amendments etc, complete. 5.00 HP/3.7KW, 25 STG. | Nos | 29568.0 | 29568.0 | 1.0 | False | None | None | False | None | False | 29568.0 | 0 |
3845145 | 146735 | None | code256 | INTERNAL WIRING -Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory-19/20mm Dia 2mm Thick | m | 61.0 | 61.0 | 1496.0 | False | None | None | False | None | False | 91256.0 | 0 |
3845146 | 146735 | None | code257 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory-19/20mm Dia 2mm Thick-25mm dia 2mm Thick | m | 70.0 | 70.0 | 2059.0 | False | None | None | False | None | False | 144130.0 | 0 |
3845147 | 146735 | None | code258 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory-19/20mm Dia 2mm Thick-32mm dia 2.5mm thick | m | 93.0 | 93.0 | 50.0 | False | None | None | False | None | False | 4650.0 | 0 |
3845148 | 146735 | None | code259 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory-19/20mm Dia 2mm Thick | m | 75.0 | 75.0 | 1100.0 | False | None | None | False | None | False | 82500.0 | 0 |
3845149 | 146735 | None | code260 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory-25mm dia 2mm Thick | m | 80.0 | 80.0 | 1100.0 | False | None | None | False | None | False | 88000.0 | 0 |
3845150 | 146735 | None | code261 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory-32mm dia 2.5mm thick | m | 105.0 | 105.0 | 60.0 | False | None | None | False | None | False | 6300.0 | 0 |
3845151 | 146735 | None | code262 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes-19/20 mm Deep Junction Box | Each | 49.0 | 49.0 | 239.0 | False | None | None | False | None | False | 11711.0 | 0 |
3845152 | 146735 | None | code263 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes-25 mm Deep Junction Box | Each | 51.0 | 51.0 | 87.0 | False | None | None | False | None | False | 4437.0 | 0 |
3845153 | 146735 | None | code264 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes-32 mm deep Junction Box | Each | 69.0 | 69.0 | 30.0 | False | None | None | False | None | False | 2070.0 | 0 |
3845154 | 146735 | None | code265 | Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc-20 mm | m | 27.0 | 27.0 | 150.0 | False | None | None | False | None | False | 4050.0 | 0 |
3845155 | 146735 | None | code266 | Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc-25 mm | m | 28.0 | 28.0 | 150.0 | False | None | None | False | None | False | 4200.0 | 0 |
3845156 | 146735 | None | code267 | Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc-32 mm | m | 41.0 | 41.0 | 50.0 | False | None | None | False | None | False | 2050.0 | 0 |
3845157 | 146735 | None | code268 | Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly-20 mm | m | 25.0 | 25.0 | 200.0 | False | None | None | False | None | False | 5000.0 | 0 |
3845158 | 146735 | None | code269 | Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly-25 mm | m | 31.0 | 31.0 | 200.0 | False | None | None | False | None | False | 6200.0 | 0 |
3845159 | 146735 | None | code270 | Supply & Fixing of Metal fan box with round Hook | Each | 163.0 | 163.0 | 45.0 | False | None | None | False | None | False | 7335.0 | 0 |
3845160 | 146735 | None | code271 | Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Make : KEI / Polycab/ Finolex-Short point upto 3 Mtd. From Tapping point to outlet via switch box. | Point | 251.0 | 251.0 | 115.0 | False | None | None | False | None | False | 28865.0 | 0 |
3845161 | 146735 | None | code272 | Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Make : KEI / Polycab/ Finolex-Medium point above 3 Mts upto 6 Mts. From tapping point to outlet via switch box. | Point | 361.0 | 361.0 | 110.0 | False | None | None | False | None | False | 39710.0 | 0 |
3845162 | 146735 | None | code273 | Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Make : KEI / Polycab/ Finolex-Long point above 6 Mts. Upto 10 Mts. From tapping of point to outlet via switch box. | Point | 542.0 | 542.0 | 85.0 | False | None | None | False | None | False | 46070.0 | 0 |
3845163 | 146735 | None | code274 | Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Make : KEI / Polycab/ Finolex-Two outlet in a row above 3 Mts upto 6 Mts, from tapping point to outlet via switch box. | Point | 671.0 | 671.0 | 25.0 | False | None | None | False | None | False | 16775.0 | 0 |
3845164 | 146735 | None | code275 | Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Make : KEI / Polycab/ Finolex-Three outlet in a row, above 6 Mts. Upto 10 Mts. From tapping point to outlet via switch box. | Point | 979.0 | 979.0 | 32.0 | False | None | None | False | None | False | 31328.0 | 0 |
3845165 | 146735 | None | code276 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-1.5 Sqmm | m | 26.0 | 26.0 | 2659.0 | False | None | None | False | None | False | 69134.0 | 0 |
3845166 | 146735 | None | code277 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-2.5Sqmm | m | 40.0 | 40.0 | 3695.0 | False | None | None | False | None | False | 147800.0 | 0 |
3845167 | 146735 | None | code278 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-4Sqmm | m | 59.0 | 59.0 | 2600.0 | False | None | None | False | None | False | 153400.0 | 0 |
3845168 | 146735 | None | code279 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-10Sqmm | m | 157.0 | 157.0 | 300.0 | False | None | None | False | None | False | 47100.0 | 0 |
3845169 | 146735 | None | code280 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-16Sqmm | m | 318.0 | 318.0 | 200.0 | False | None | None | False | None | False | 63600.0 | 0 |
3845170 | 146735 | None | code281 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-1-3 way | Each | 123.0 | 123.0 | 35.0 | False | None | None | False | None | False | 4305.0 | 0 |
3845171 | 146735 | None | code282 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-4-5 way | Each | 138.0 | 138.0 | 30.0 | False | None | None | False | None | False | 4140.0 | 0 |
3845172 | 146735 | None | code283 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-6 way | Each | 212.0 | 212.0 | 18.0 | False | None | None | False | None | False | 3816.0 | 0 |
3845173 | 146735 | None | code284 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-8 way | Each | 250.0 | 250.0 | 13.0 | False | None | None | False | None | False | 3250.0 | 0 |
3845174 | 146735 | None | code285 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-12 way | Each | 325.0 | 325.0 | 8.0 | False | None | None | False | None | False | 2600.0 | 0 |
3845175 | 146735 | None | code286 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-16 way | Each | 354.0 | 354.0 | 6.0 | False | None | None | False | None | False | 2124.0 | 0 |
3845176 | 146735 | None | code287 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box1-3 way | Each | 152.0 | 152.0 | 35.0 | False | None | None | False | None | False | 5320.0 | 0 |
3845177 | 146735 | None | code288 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-4-5 way | Each | 175.0 | 175.0 | 30.0 | False | None | None | False | None | False | 5250.0 | 0 |
3845178 | 146735 | None | code289 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-6 way | Each | 244.0 | 244.0 | 18.0 | False | None | None | False | None | False | 4392.0 | 0 |
3845179 | 146735 | None | code290 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-8 way | Each | 302.0 | 302.0 | 13.0 | False | None | None | False | None | False | 3926.0 | 0 |
3845180 | 146735 | None | code291 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-10-12 way | Each | 363.0 | 363.0 | 12.0 | False | None | None | False | None | False | 4356.0 | 0 |
3845181 | 146735 | None | code292 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-16 way | Each | 403.0 | 403.0 | 10.0 | False | None | None | False | None | False | 4030.0 | 0 |
3845182 | 146735 | None | code293 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6 Amp one way | Each | 88.0 | 88.0 | 188.0 | False | None | None | False | None | False | 16544.0 | 0 |
3845183 | 146735 | None | code294 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6 Amps 2 way | Each | 152.0 | 152.0 | 12.0 | False | None | None | False | None | False | 1824.0 | 0 |
3845184 | 146735 | None | code295 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6 Amps socket | Each | 162.0 | 162.0 | 65.0 | False | None | None | False | None | False | 10530.0 | 0 |
3845185 | 146735 | None | code296 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -Stepped Fan Regulator | Each | 313.0 | 313.0 | 45.0 | False | None | None | False | None | False | 14085.0 | 0 |
3845186 | 146735 | None | code297 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -16 Amps 1 way switch | Each | 249.0 | 249.0 | 61.0 | False | None | None | False | None | False | 15189.0 | 0 |
3845187 | 146735 | None | code298 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6 Amps Bell Push | Each | 159.0 | 159.0 | 2.0 | False | None | None | False | None | False | 318.0 | 0 |
3845188 | 146735 | None | code299 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -32 Amps DP Switch | Each | 375.0 | 375.0 | 55.0 | False | None | None | False | None | False | 20625.0 | 0 |
3845189 | 146735 | None | code300 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6/16 Amps universal socket | Each | 249.0 | 249.0 | 61.0 | False | None | None | False | None | False | 15189.0 | 0 |
3845190 | 146735 | None | code301 | Supply and fixing of -Led Light Fixture 2 feet - 9/10 W-Make : Panasonic/Phillips / Crompton | Each | 496.0 | 496.0 | 17.0 | False | None | None | False | None | False | 8432.0 | 0 |
3845191 | 146735 | None | code302 | Supply and fixing of -Led Light Fixture 4 feet - 20/22 W | Each | 740.0 | 740.0 | 61.0 | False | None | None | False | None | False | 45140.0 | 0 |
3845192 | 146735 | None | code303 | Supply of recess mounted rolling type LED square or round Light 12 watta | Each | 835.0 | 835.0 | 56.0 | False | None | None | False | None | False | 46760.0 | 0 |
3845193 | 146735 | None | code304 | Supply and fixing of -LED Modular Down Light 2' x 2 ' - 36 W | Each | 5651.0 | 5651.0 | 92.0 | False | None | None | False | None | False | 519892.0 | 0 |
3845194 | 146735 | None | code305 | Fabrication and supply of sheet steel enclosure out of 14 SWG CRCA Sheet duly powder coated the contro panel ( Size of 2000 x1500x 450 ) is of compartment alized, All the components are duly wired and connected to Aluminum bus bar.-Make : Legrand / Schneider / Anchor / L&T | Sq CM | 0.43 | 0.43 | 70000.0 | False | None | None | False | None | False | 30100.0 | 0 |
3845195 | 146735 | None | code306 | Supplying and fixing of 100 A 4 x 30 x 10 mm Alumunium Strips | m | 2214.0 | 2214.0 | 6.0 | False | None | None | False | None | False | 13284.0 | 0 |
3845196 | 146735 | None | code307 | Supplying and fixing of 400 A 4 x 50 x 10 mm Alumunium Strips | m | 3996.0 | 3996.0 | 6.0 | False | None | None | False | None | False | 23976.0 | 0 |
3845197 | 146735 | None | code308 | Supplying and fixing-16 sqmm wire | m | 318.0 | 318.0 | 40.0 | False | None | None | False | None | False | 12720.0 | 0 |
3845198 | 146735 | None | code309 | Supplying and fixing of LED Panel Board indicating Lamp with required colour Suitable for 220 V AC 50 HZ | Each | 464.0 | 464.0 | 9.0 | False | None | None | False | None | False | 4176.0 | 0 |
3845199 | 146735 | None | code310 | Supplying of Multifunction Digital Meter | Each | 8370.0 | 8370.0 | 1.0 | False | None | None | False | None | False | 8370.0 | 0 |
3845200 | 146735 | None | code311 | Supplying and fixing-250A ATS | Each | 102600.0 | 102600.0 | 1.0 | False | None | None | False | None | False | 102600.0 | 0 |
3845201 | 146735 | None | code312 | Supplying and fixing of 400 A MCCB | Each | 29092.0 | 29092.0 | 1.0 | False | None | None | False | None | False | 29092.0 | 0 |
3845202 | 146735 | None | code313 | Supplying and fixing of 200 A MCCB | Each | 21289.0 | 21289.0 | 1.0 | False | None | None | False | None | False | 21289.0 | 0 |
3845203 | 146735 | None | code314 | Supplying and fixing-63A 4P MCB | Each | 2399.0 | 2399.0 | 6.0 | False | None | None | False | None | False | 14394.0 | 0 |
3845204 | 146735 | None | code315 | Supplying and fixing-5 - 32 A TPN | Nos | 1777.0 | 1777.0 | 13.0 | False | None | None | False | None | False | 23101.0 | 0 |
3845205 | 146735 | None | code316 | Supplying and fixing of Earth leakage relay | Each | 8316.0 | 8316.0 | 1.0 | False | None | None | False | None | False | 8316.0 | 0 |
3845206 | 146735 | None | code317 | Supplying and fixing of 50 x 50 x 6 mm Angle | m | 356.0 | 356.0 | 20.0 | False | None | None | False | None | False | 7120.0 | 0 |
3845207 | 146735 | None | code318 | Fabrication and supply of sheet steel enclosure out of 14 SWG CRCA Sheet duly powder coated the contro panel ( Size of 2000 x1500x 450 ) is of compartment alized, All the components are duly wired and connected to Aluminum bus bar. | Sq CM | 0.43 | 0.43 | 35000.0 | False | None | None | False | None | False | 15050.0 | 0 |
3845208 | 146735 | None | code319 | Supplying and fixing of 100 A 4 x 30 x 10 mm Alumunium Strips | m | 2214.0 | 2214.0 | 6.0 | False | None | None | False | None | False | 13284.0 | 0 |
3845209 | 146735 | None | code320 | Supplying and fixing of LED Panel Board indicating Lamp with required colour Suitable for 220 V AC 50 HZ | Each | 464.0 | 464.0 | 15.0 | False | None | None | False | None | False | 6960.0 | 0 |
3845210 | 146735 | None | code321 | Supply , fixing and wiring of Automatic Poer Factor Controller | Each | 19440.0 | 19440.0 | 1.0 | False | None | None | False | None | False | 19440.0 | 0 |
3845211 | 146735 | None | code322 | Supplying and fixing of 40 - 63 Amps TPN MCB | Each | 2399.0 | 2399.0 | 1.0 | False | None | None | False | None | False | 2399.0 | 0 |
3845212 | 146735 | None | code323 | Supplying and fixing of 5 - 32 A TPN | Nos | 1777.0 | 1777.0 | 6.0 | False | None | None | False | None | False | 10662.0 | 0 |
3845213 | 146735 | None | code324 | Supplying and fixing of 25 Amps | Each | 1187.0 | 1187.0 | 6.0 | False | None | None | False | None | False | 7122.0 | 0 |
3845214 | 146735 | None | code325 | Supplying and fixing of Heavy Duty low Voltage Capacitors | Kvar | 432.0 | 432.0 | 30.0 | False | None | None | False | None | False | 12960.0 | 0 |
3845215 | 146735 | None | code326 | Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-4Way SP &N | Nos | 1368.0 | 1368.0 | 1.0 | False | None | None | False | None | False | 1368.0 | 0 |
3845216 | 146735 | None | code327 | Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-8Way SP &N | Nos | 1695.0 | 1695.0 | 1.0 | False | None | None | False | None | False | 1695.0 | 0 |
3845217 | 146735 | None | code328 | Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-12Way SP &N | Nos | 2067.0 | 2067.0 | 1.0 | False | None | None | False | None | False | 2067.0 | 0 |
3845218 | 146735 | None | code329 | Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-6Way TP &N | Nos | 3735.0 | 3735.0 | 1.0 | False | None | None | False | None | False | 3735.0 | 0 |
3845219 | 146735 | None | code330 | Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-8Way TP &N | Nos | 4136.0 | 4136.0 | 2.0 | False | None | None | False | None | False | 8272.0 | 0 |
3845220 | 146735 | None | code331 | Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-12Way TP &N | Nos | 5744.0 | 5744.0 | 3.0 | False | None | None | False | None | False | 17232.0 | 0 |
3845221 | 146735 | None | code332 | Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board-16 - 25 Amps 2 pole | Nos | 2536.0 | 2536.0 | 3.0 | False | None | None | False | None | False | 7608.0 | 0 |
3845222 | 146735 | None | code333 | Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board-32 - 40 Amps 2 pole | Nos | 2652.0 | 2652.0 | 10.0 | False | None | None | False | None | False | 26520.0 | 0 |
3845223 | 146735 | None | code334 | Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board-32 - 40 Amps 4 pole | Nos | 2826.0 | 2826.0 | 2.0 | False | None | None | False | None | False | 5652.0 | 0 |
3845224 | 146735 | None | code335 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-5 - 32 Amp SP | Nos | 523.0 | 523.0 | 70.0 | False | None | None | False | None | False | 36610.0 | 0 |
3845225 | 146735 | None | code336 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-40 - 63 Amps SP | Nos | 726.0 | 726.0 | 4.0 | False | None | None | False | None | False | 2904.0 | 0 |
3845226 | 146735 | None | code337 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-5 - 32 Amp DP | Nos | 1103.0 | 1103.0 | 6.0 | False | None | None | False | None | False | 6618.0 | 0 |
3845227 | 146735 | None | code338 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-40 - 63 Amp DP | Nos | 1376.0 | 1376.0 | 6.0 | False | None | None | False | None | False | 8256.0 | 0 |
3845228 | 146735 | None | code339 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-5 - 32 A TPN | Nos | 1777.0 | 1777.0 | 2.0 | False | None | None | False | None | False | 3554.0 | 0 |
3845229 | 146735 | None | code340 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-40 - 63 Amp TPN | Nos | 2399.0 | 2399.0 | 6.0 | False | None | None | False | None | False | 14394.0 | 0 |
3845230 | 146735 | None | code341 | Supplying Fixing and Wiring earth electrode for grounding of lifts,Xmer, DG Sets etc using 40mm dia 2.9mm thick, 2.5mtr long GI pipe with GI funnel with mesh & suitable size reducer fixed on the top of Electrode. The funnel should be enclosed in a cc chamber of 400x400x400 with a cast iron cover. The Earth electrode shall have staggered holes of 12mm dia & electrode shoulde be covered 150mm around with alternate layers of salt & charcoal from the bottom of the CC Chamber. The connection from the electrode is to be established throgh GI strip using GI bolts & nuts. | Nos | 4150.0 | 4150.0 | 8.0 | False | None | None | False | None | False | 33200.0 | 0 |
3845231 | 146735 | None | code342 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required….. 25 x 3 mm G.I strip.GI Strip | m | 75.0 | 75.0 | 100.0 | False | None | None | False | None | False | 7500.0 | 0 |
3845232 | 146735 | None | code343 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required….. 600x600x3 GI Plate.GI Strip | Each | 760.0 | 760.0 | 2.0 | False | None | None | False | None | False | 1520.0 | 0 |
3845233 | 146735 | None | code344 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required…..-25 x 3 mm -Cu. Strip | m | 505.0 | 505.0 | 50.0 | False | None | None | False | None | False | 25250.0 | 0 |
3845234 | 146735 | None | code345 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required…..-600x600x3 Cu. Plate-Cu. Strip | Each | 6900.0 | 6900.0 | 2.0 | False | None | None | False | None | False | 13800.0 | 0 |
3845235 | 146735 | None | code346 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required…-12 SWG GI wire-GI wire | m | 14.0 | 14.0 | 200.0 | False | None | None | False | None | False | 2800.0 | 0 |
3845236 | 146735 | None | code347 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-12 SWG | m | 58.0 | 58.0 | 50.0 | False | None | None | False | None | False | 2900.0 | 0 |
3845237 | 146735 | None | code348 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required10 SWG | m | 68.0 | 68.0 | 50.0 | False | None | None | False | None | False | 3400.0 | 0 |
3845238 | 146735 | None | code349 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-8 SWG | m | 105.0 | 105.0 | 50.0 | False | None | None | False | None | False | 5250.0 | 0 |
3845239 | 146735 | None | code350 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-2C x 10sq.mm. Al. Alum. Cable | m | 95.0 | 95.0 | 200.0 | False | None | None | False | None | False | 19000.0 | 0 |
3845240 | 146735 | None | code351 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-4C x 10sq.mm. Al. Alum. Cable | m | 130.0 | 130.0 | 150.0 | False | None | None | False | None | False | 19500.0 | 0 |
3845241 | 146735 | None | code352 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-4C x 16sq.mm. Al. Alum. Cable | m | 150.0 | 150.0 | 100.0 | False | None | None | False | None | False | 15000.0 | 0 |
3845242 | 146735 | None | code353 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-3.5C x 120sq.mm. Al. Alum. Cable | m | 600.0 | 600.0 | 50.0 | False | None | None | False | None | False | 30000.0 | 0 |
3845243 | 146735 | None | code354 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-3.5C x 240sq.mm. Al. Alum. Cable | m | 1130.0 | 1130.0 | 100.0 | False | None | None | False | None | False | 113000.0 | 0 |
3845244 | 146735 | None | code355 | Supply & Fixing of Heavy Duty Cable Glands Suitable For UG Cable of 1.1KV Class (metal Only)-25mm Dia | Nos | 84.0 | 84.0 | 30.0 | False | None | None | False | None | False | 2520.0 | 0 |
3845245 | 146735 | None | code356 | Supply & Fixing of Heavy Duty Cable Glands Suitable For UG Cable of 1.1KV Class (metal Only)-63mm Dia | Nos | 388.0 | 388.0 | 8.0 | False | None | None | False | None | False | 3104.0 | 0 |
3845246 | 146735 | None | code357 | Supplying Tinned Cu. Lugs & crimping & wiring to terminal Point for Wire of following sizes -16sq.mm. long Barrel | Nos | 12.44 | 12.44 | 18.0 | False | None | None | False | None | False | 223.92 | 0 |
3845247 | 146735 | None | code358 | Supplying Tinned Cu. Lugs & crimping & wiring to terminal Point for Wire of following sizes -240Sqmm Long Barrel | Nos | 463.0 | 463.0 | 6.0 | False | None | None | False | None | False | 2778.0 | 0 |
3845248 | 146735 | None | code359 | Supplying Tinned Cu. Lugs & crimping & wiring to terminal Point for Wire of following sizes -120 Sqmm Long Barrel | Nos | 190.0 | 190.0 | 50.0 | False | None | None | False | None | False | 9500.0 | 0 |
3845249 | 146735 | None | code360 | Supply & Fixing 2mm thick perforated cable tray with powder coated paint on exising MS Angle support using necessary GI bolts , nuts & washer or welding as required:-150 mmX 50 MM wide tray ( Perforated type ) | m | 425.0 | 425.0 | 20.0 | False | None | None | False | None | False | 8500.0 | 0 |
3845250 | 146735 | None | code361 | Supply & Fixing 2mm thick perforated cable tray with powder coated paint on exising MS Angle support using necessary GI bolts , nuts & washer or welding as required:-300 mm x 50 mm wide cabel tray ( Perforated type ) | m | 530.0 | 530.0 | 20.0 | False | None | None | False | None | False | 10600.0 | 0 |
3845251 | 146735 | None | code362 | Supplying exhaust fan 0f 1440 RPM of300 mm (12") size with bracket blades complte for light duty suitable to operate on 230V 50 Hz AC Supply-Make Fans : Crompton / Usha / Anchor | Each | 1542.0 | 1542.0 | 15.0 | False | None | None | False | None | False | 23130.0 | 0 |
3845252 | 146735 | None | code363 | Supplying capacitor type ceiling Fan complete with down rod blades shackle ,canopies etc. for operation on 230 Vots 50 cycles ,single phase AC supply confirming to ISS -374-1979 with double ball bearing system-48 " Sweep Economy model | Each | 2085.0 | 2085.0 | 35.0 | False | None | None | False | None | False | 72975.0 | 0 |
3845253 | 146735 | None | code364 | Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories
covered with insulation tube including battery operated cordless unit-4.0 TR Cassette 3 Ph | Nos | 141255.0 | 141255.0 | 10.0 | False | None | None | False | None | False | 1412550.0 | 0 |
3845254 | 146735 | None | code365 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type | Each | 4981.0 | 4981.0 | 10.0 | False | None | None | False | None | False | 49810.0 | 0 |
3845255 | 146735 | None | code366 | Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3core 80 stand copper wiring between indoor and outdoorunit Leak testing oil and gas charging for additional piping-Cassette | m | 1763.0 | 1763.0 | 250.0 | False | None | None | False | None | False | 440750.0 | 0 |
3845256 | 146735 | None | code367 | Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3core 80 stand copper wiring between indoor and outdoorunit Leak testing oil and gas charging for additional piping4C x 4 sqmm Copper flexible cable | m | 158.0 | 158.0 | 300.0 | False | None | None | False | None | False | 47400.0 | 0 |
3845257 | 146735 | None | code368 | Supplying and installation of -5KVA offline UPS | Nos | 38661.0 | 38661.0 | 1.0 | False | None | None | False | None | False | 38661.0 | 0 |
3845258 | 146735 | None | code369 | Supplying and installation of -12V , 200 AH Capacity Acid Battery | Nos | 15783.0 | 15783.0 | 2.0 | False | None | None | False | None | False | 31566.0 | 0 |
3845259 | 146735 | None | code370 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. andfixing using invetred wood plugs in Case of RCC ceiling and RCC wall /stone structure or rawl plug incase of brick walls and cement plastering the damaged portion using heavy guage saddles in an intervel of 700 mm using NF Screws-\19/20mm Dia 2mm Thick | m | 68.0 | 68.0 | 200.0 | False | None | None | False | None | False | 13600.0 | 0 |
3845260 | 146735 | None | code371 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. andfixing using invetred wood plugs in Case of RCC ceiling and RCC wall /stone structure or rawl plug incase of brick walls and cement plastering the damaged portion using heavy guage saddles in an intervel of 700 mm using NF Screws-25mm dia 2mm Thick | m | 80.0 | 80.0 | 100.0 | False | None | None | False | None | False | 8000.0 | 0 |
3845261 | 146735 | None | code372 | Supplying and drawing pvc insulated gas injected physical foam jelly filled co axial TV Cable Rg6 | m | 42.0 | 42.0 | 200.0 | False | None | None | False | None | False | 8400.0 | 0 |
3845262 | 146735 | None | code373 | Supply & Fixing of 4 Pair Telephone wire | m | 33.0 | 33.0 | 200.0 | False | None | None | False | None | False | 6600.0 | 0 |
3845263 | 146735 | None | code374 | Supplying & drawing UTP Cat 6 E Lan Cable | m | 34.0 | 34.0 | 400.0 | False | None | None | False | None | False | 13600.0 | 0 |
3845264 | 146735 | None | code375 | Supply & Fixing of Single I/0 | Each | 405.0 | 405.0 | 10.0 | False | None | None | False | None | False | 4050.0 | 0 |
3845265 | 146735 | None | code376 | Supply & Fixing of Double I/O | Each | 727.0 | 727.0 | 15.0 | False | None | None | False | None | False | 10905.0 | 0 |
3845266 | 146735 | None | code377 | Supply & Fixing of T.V telephone Socket | Each | 147.0 | 147.0 | 20.0 | False | None | None | False | None | False | 2940.0 | 0 |
3845267 | 146735 | None | code378 | Supply & Fixing of 12U with 800 mm depth | Each | 9271.0 | 9271.0 | 1.0 | False | None | None | False | None | False | 9271.0 | 0 |
3845268 | 146735 | None | code379 | Supplying & Fixing of power Strip | Each | 1233.0 | 1233.0 | 1.0 | False | None | None | False | None | False | 1233.0 | 0 |
3845269 | 146735 | None | code380 | Supply & Fixing of 24 port 10 / 100 /1000 Switch | Each | 8241.0 | 8241.0 | 1.0 | False | None | None | False | None | False | 8241.0 | 0 |
3845270 | 146735 | None | code381 | Supply & Fixing of 1 Mtr patch cable | Each | 190.0 | 190.0 | 15.0 | False | None | None | False | None | False | 2850.0 | 0 |
3845271 | 146735 | None | code382 | Supply & Fixing of 2 Mtr patch cable | Each | 286.0 | 286.0 | 15.0 | False | None | None | False | None | False | 4290.0 | 0 |
3845272 | 146735 | None | code383 | Supply & Fixing of 24 port 10 / 100 patch panel | Each | 4258.0 | 4258.0 | 1.0 | False | None | None | False | None | False | 4258.0 | 0 |
3845273 | 146735 | None | code384 | Fabricating, supplying and erection of ...Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom …..mm, top….mm with 3/4mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the pole shall be galvanized with not less than 65micron etc as per ASTM-A 123 and 153 etc., (excluding foundation) as per drawing appended. a)3 Meters-Top 70mm and bottom 130mm dia | Each | 5671.0 | 5671.0 | 4.0 | False | None | None | False | None | False | 22684.0 | 0 |
3845274 | 146735 | None | code385 | Fabricating, supplying and erection of ...Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom …..mm, top….mm with 3/4mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the pole shall be galvanized with not less than 65micron etc as per ASTM-A 123 and 153 etc., (excluding foundation) as per drawing appended. b)5 Meters-Top 70mm and bottom 130mm dia | Each | 8871.0 | 8871.0 | 4.0 | False | None | None | False | None | False | 35484.0 | 0 |
3845275 | 146735 | None | code386 | Supplying and fixing Led Street Light70 watts | Each | 5955.0 | 5955.0 | 8.0 | False | None | None | False | None | False | 47640.0 | 0 |
3845276 | 146735 | None | code387 | Supplying and fixing 4C x 16sq.mm. Al. Alum. Cable | m | 150.0 | 150.0 | 150.0 | False | None | None | False | None | False | 22500.0 | 0 |
3845277 | 146735 | None | code388 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete | m | 102.0 | 102.0 | 120.0 | False | None | None | False | None | False | 12240.0 | 0 |
3845278 | 146735 | None | code389 | Labour charges for laying of 1.1 KV class UG cable when supplied agency in existing trench GI pipe / stoneware pipe / on wall / on pole as required.(69/5) - In exixting trench/duct. 6sqmm to 16 sqmm | m | 11.8 | 11.8 | 150.0 | False | None | None | False | None | False | 1770.0 | 0 |
3845279 | 146735 | None | code390 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable (Sl no 7.10 page no 62) | m | 100.0 | 100.0 | 150.0 | False | None | None | False | None | False | 15000.0 | 0 |
3845280 | 146735 | None | code391 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 Sqmm | Each | 12.44 | 12.44 | 26.0 | False | None | None | False | None | False | 323.44 | 0 |
3845281 | 146735 | None | code392 | Supplying and fixing 25mm Dia | Nos | 80.0 | 80.0 | 100.0 | False | None | None | False | None | False | 8000.0 | 0 |
3845282 | 146735 | None | code393 | Supplying and fixing 70 Watt Led Flood light | Nos | 7390.0 | 7390.0 | 4.0 | False | None | None | False | None | False | 29560.0 | 0 |
3845283 | 146735 | None | code394 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130- 1984 and (Virgin) PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A-4C x 2.5 sqmm | m | 141.0 | 141.0 | 200.0 | False | None | None | False | None | False | 28200.0 | 0 |
3845284 | 146735 | None | code395 | Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -6Way TP &N | Nos | 3735.0 | 3735.0 | 1.0 | False | None | None | False | None | False | 3735.0 | 0 |
3845285 | 146735 | None | code396 | Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board-16 - 25 Amps 2 pole | Nos | 2536.0 | 2536.0 | 3.0 | False | None | None | False | None | False | 7608.0 | 0 |
3845286 | 146735 | None | code397 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-5 - 32 Amp SP | Nos | 523.0 | 523.0 | 4.0 | False | None | None | False | None | False | 2092.0 | 0 |
3845287 | 146735 | None | code398 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-40 - 63 Amps SP | Nos | 726.0 | 726.0 | 4.0 | False | None | None | False | None | False | 2904.0 | 0 |
3845288 | 146735 | None | code399 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-8W 0.5 Mtr Height Bollard Light | Nos | 3391.0 | 3391.0 | 8.0 | False | None | None | False | None | False | 27128.0 | 0 |
3845289 | 146735 | None | code400 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-LED Post Top Lantern with 25 Watt | Nos | 7173.0 | 7173.0 | 5.0 | False | None | None | False | None | False | 35865.0 | 0 |
3845290 | 146735 | None | code401 | Supply, installation, testing and commisioning of Flush mount model chairman unit with gooseneck mic with ring LED and intreconnection cable and out socket for linking next units with talk and priority switch with delegate inter face unit aliminum/ PVC Housing | Nos | 34800.0 | 34800.0 | 1.0 | False | None | None | False | None | False | 34800.0 | 0 |
3845291 | 146735 | None | code402 | Supply, installation, testing and commisioning of Flush mount model delegate unit with gooseneck mic with ring LED and intreconnection cable and out socket for linking next units with talk and priority switch with delegate inter face unit aliminum/ PVC Housing | Nos | 32800.0 | 32800.0 | 1.0 | False | None | None | False | None | False | 32800.0 | 0 |
3845292 | 146735 | None | code403 | Supply, installation, testing and commisioning of Table top model chairman unit with gooseneck mic with ring LED and intreconnection cable and out socket for linking next units with talk and priority switch with delegate inter face unit aliminum/ PVC Housing and Headphone socket | Nos | 12400.0 | 12400.0 | 1.0 | False | None | None | False | None | False | 12400.0 | 0 |
3845293 | 146735 | None | code404 | Supply, installation, testing and commisioning of Table top model delegate unit with gooseneck mic with ring LED and intreconnection cable and out socket for linking next units with talk and priority switch with delegate inter face unit aliminum/ PVC Housing and Headphone socket | Nos | 12400.0 | 12400.0 | 1.0 | False | None | None | False | None | False | 12400.0 | 0 |
3845294 | 146735 | None | code405 | Supply, installation, testing and commisioning of controller unit with 1 mic input 1aux PA out, rack mountable can handle up to 50 to 300 delegate units with expansion options | Nos | 174000.0 | 174000.0 | 1.0 | False | None | None | False | None | False | 174000.0 | 0 |
3845295 | 146735 | None | code406 | Supply, installation, testing and commisioning of controller unit with 1 mic input 1aux PA out, rack mountable can handle up to 60 delegate units with expansion options | Nos | 103.0 | 103.0 | 55.0 | False | None | None | False | None | False | 5665.0 | 0 |
3845296 | 146735 | None | code407 | Supply, installation, testing and commisioning of 9 core multistrand high gain low cable with required end connectors 10 meter to connect between the delegate units and controller including charges for labour, lead and lifts, loading and unloading | Nos | 220.0 | 220.0 | 5.0 | False | None | None | False | None | False | 1100.0 | 0 |
3845297 | 146735 | None | code408 | Supply, installation, testing and commisioning of compact ceiling speaker with Back Can Power handling up to 6 watt RMS/watt/100volt @ 1456 ohms single channel selectable taping 5'' LF driver and tweeter | Nos | 1450.0 | 1450.0 | 10.0 | False | None | None | False | None | False | 14500.0 | 0 |
3845298 | 146735 | None | code409 | Supplying, installing and commissioning of CCTV Surveillance System.-CCTV Surveillance Cameras-Indoor Dome IR Camera, HD Video | Nos | 6900.0 | 6900.0 | 12.0 | False | None | None | False | None | False | 82800.0 | 0 |
3845299 | 146735 | None | code410 | Outdoor Bullet- 25 Mtrs Range, HD Video | Nos | 7500.0 | 7500.0 | 2.0 | False | None | None | False | None | False | 15000.0 | 0 |
3845300 | 146735 | None | code411 | Power Supply 12VDC, Each Supports upto 5 IR Cameras | Nos | 3300.0 | 3300.0 | 5.0 | False | None | None | False | None | False | 16500.0 | 0 |
3845301 | 146735 | None | code412 | 16 Channel DVR, HD, with 2TB Surveillance HDD | Nos | 57000.0 | 57000.0 | 1.0 | False | None | None | False | None | False | 57000.0 | 0 |
3845302 | 146735 | None | code413 | 19 Color Monitor For DVR | Nos | 10440.0 | 10440.0 | 1.0 | False | None | None | False | None | False | 10440.0 | 0 |
3845303 | 146735 | None | code414 | CCTV Cabling including PVC Conduit | m | 114.0 | 114.0 | 700.0 | False | None | None | False | None | False | 79800.0 | 0 |
3845304 | 146735 | None | code415 | Supplying , Errection , Testing and Commissioning of Diesel Generator Set on existing CC platform comprising of Diesel Engine developing -----BHP @1500 RPM confirming to BS 5514-62.5 KVA /50 KW | Nos | 618585.0 | 618585.0 | 1.0 | False | None | None | False | None | False | 618585.0 | 0 |
3845305 | 146735 | None | code416 | Supply , Erection , Testing and commissioning of AMF Panel suitable for DG Set-up to 62.5 KVA | Nos | 75900.0 | 75900.0 | 1.0 | False | None | None | False | None | False | 75900.0 | 0 |
3845306 | 146735 | None | code417 | SUMP TANK-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m- | Cum | 114.24 | 114.24 | 47.8 | False | None | None | False | None | False | 5460.672 | 0 |
3845307 | 146735 | None | code418 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates- | Cum | 6992.16 | 6992.16 | 3.88 | False | None | None | False | None | False | 27129.5808 | 0 |
3845308 | 146735 | None | code419 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.- | Cum | 297.92 | 297.92 | 2.3 | False | None | None | False | None | False | 685.216 | 0 |
3845309 | 146735 | None | code420 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- FOOTING | Cum | 8277.29 | 8277.29 | 3.39 | False | None | None | False | None | False | 28060.0131 | 0 |
3845310 | 146735 | None | code421 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- RCC WALL | Cum | 13029.07 | 13029.07 | 6.59 | False | None | None | False | None | False | 85861.5713 | 0 |
3845311 | 146735 | None | code422 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- SLAB | Cum | 11496.24 | 11496.24 | 2.75 | False | None | None | False | None | False | 31614.66 | 0 |
3845312 | 146735 | None | code423 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2. | Sqm | 371.84 | 371.84 | 80.2 | False | None | None | False | None | False | 29821.568 | 0 |
3845313 | 146735 | None | code424 | KSRB 12-6.2: Providing 20mm round M.S. footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 286.72 | 286.72 | 10.0 | False | None | None | False | None | False | 2867.2 | 0 |
3845314 | 146735 | None | code425 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SL.NO-11.32, PG.NO-84, VOLUME-II. | Tonne | 88492.32 | 88492.32 | 1.27 | False | None | None | False | None | False | 112385.2464 | 0 |
3845315 | 146735 | None | code426 | SEPTIK TANK-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m- | Cum | 114.24 | 114.24 | 47.8 | False | None | None | False | None | False | 5460.672 | 0 |
3845316 | 146735 | None | code427 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates. sl.no-2.1.2, pg.no-15. volume-1 | Cum | 6992.16 | 6992.16 | 3.88 | False | None | None | False | None | False | 27129.5808 | 0 |
3845317 | 146735 | None | code428 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.- | Cum | 297.92 | 297.92 | 2.3 | False | None | None | False | None | False | 685.216 | 0 |
3845318 | 146735 | None | code429 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- FOOTING | Cum | 8277.29 | 8277.29 | 3.39 | False | None | None | False | None | False | 28060.0131 | 0 |
3845319 | 146735 | None | code430 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- RCC WALL | Cum | 13029.07 | 13029.07 | 9.0 | False | None | None | False | None | False | 117261.63 | 0 |
3845320 | 146735 | None | code431 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- SLAB | Cum | 11496.24 | 11496.24 | 2.75 | False | None | None | False | None | False | 31614.66 | 0 |
3845321 | 146735 | None | code432 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2. | Sqm | 371.84 | 371.84 | 83.3 | False | None | None | False | None | False | 30974.272 | 0 |
3845322 | 146735 | None | code433 | KSRB 12-6.2: Providing 20mm round M.S. footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 286.72 | 286.72 | 10.0 | False | None | None | False | None | False | 2867.2 | 0 |
3845323 | 146735 | None | code434 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SL.NO-11.32, PG.NO-84, VOLUME-II. | Tonne | 88492.32 | 88492.32 | 1.51 | False | None | None | False | None | False | 133623.4032 | 0 |
3845324 | 146735 | None | code435 | BOREWELL-Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test etc. complete | Nos | 5922.56 | 5922.56 | 2.0 | False | None | None | False | None | False | 11845.12 | 0 |
3845325 | 146735 | None | code436 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 0 to 50 Mtrs | m | 414.4 | 414.4 | 50.0 | False | None | None | False | None | False | 20720.0 | 0 |
3845326 | 146735 | None | code437 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 50 to 100 Mtrs | m | 519.68 | 519.68 | 50.0 | False | None | None | False | None | False | 25984.0 | 0 |
3845327 | 146735 | None | code438 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)Borewell depth of 100 to 150 Mtrs | m | 552.16 | 552.16 | 50.0 | False | None | None | False | None | False | 27608.0 | 0 |
3845328 | 146735 | None | code439 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 150 to 200 Mtrs | m | 640.64 | 640.64 | 25.0 | False | None | None | False | None | False | 16016.0 | 0 |
3845329 | 146735 | None | code440 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)--Borewell depth of 200 to 250 Mtrs | m | 751.52 | 751.52 | 60.0 | False | None | None | False | None | False | 45091.2 | 0 |
3845330 | 146735 | None | code441 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete-5.00 HP/3.7KW-50 STG | Nos | 33208.0 | 33208.0 | 1.0 | False | None | None | False | None | False | 33208.0 | 0 |
3845331 | 146735 | None | code442 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments-1x3x6 Sqm. | m | 207.2 | 207.2 | 168.0 | False | None | None | False | None | False | 34809.6 | 0 |
3845332 | 146735 | None | code443 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments-Size 65 mm | Nos | 1736.0 | 1736.0 | 4.0 | False | None | None | False | None | False | 6944.0 | 0 |
3845333 | 146735 | None | code444 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.-3 to 6 HP pumps | Each | 11760.0 | 11760.0 | 1.0 | False | None | None | False | None | False | 11760.0 | 0 |
3845334 | 146735 | None | code445 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | m | 616.0 | 616.0 | 125.0 | False | None | None | False | None | False | 77000.0 | 0 |
3845335 | 146735 | None | code446 | Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. | Kvar | 616.0 | 616.0 | 1.0 | False | None | None | False | None | False | 616.0 | 0 |
3845336 | 146735 | None | code447 | Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI mark | Nos | 5040.0 | 5040.0 | 1.0 | False | None | None | False | None | False | 5040.0 | 0 |
3845337 | 146735 | None | code448 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. | Job | 1512.0 | 1512.0 | 1.0 | False | None | None | False | None | False | 1512.0 | 0 |
3845338 | 146735 | None | code449 | Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work- 3.5 x 10 sqmm | m | 218.4 | 218.4 | 168.0 | False | None | None | False | None | False | 36691.2 | 0 |
3845339 | 146735 | None | code450 | Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | Job | 4200.0 | 4200.0 | 1.0 | False | None | None | False | None | False | 4200.0 | 0 |
3845340 | 146735 | None | code451 | Providing and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work.-3.5x10 Sqm | Each | 504.0 | 504.0 | 1.0 | False | None | None | False | None | False | 504.0 | 0 |
3845341 | 146735 | None | code452 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments.-5 HP, size 50x40 Head 46M, Discharge 174 LPM | Each | 29587.04 | 29587.04 | 1.0 | False | None | None | False | None | False | 29587.04 | 0 |
3845342 | 146735 | None | code453 | NON SR RATES-Providing and fixing Aluminium fixtures like aldrops of size 300x16mm,tower bolts of size 200 x 12mm, latches of size 250x12mm, 100mm length oxidized iron hinges,handles of size 150mm, door stoper and door brush of approved make and quality including cost oof conveyance of all meterials and as per the direction of EIC of work with all lead and lift and as directed by the engineer in charge of works.Single shutter | Nos | 4434.0 | 4434.0 | 3.0 | False | None | None | False | None | False | 13302.0 | 0 |
3845343 | 146735 | None | code454 | Providing and fixing sash mortise lock body with cylinder outside key and inside knob suitable for flush doors including cost of materials labours etc,. Complete as per specifications | Nos | 2150.0 | 2150.0 | 3.0 | False | None | None | False | None | False | 6450.0 | 0 |
3845344 | 146735 | None | code455 | Providing supplying and fixing ss satin finish barrel bolt/aldrop-300mm for door shutters including cost of materials,labour etc., complete as per specifications., | Nos | 575.0 | 575.0 | 6.0 | False | None | None | False | None | False | 3450.0 | 0 |
3845345 | 146735 | None | code456 | Providing supplying and fixing floor mounted door stopper suitable for flush door shutters including cost of materials,labour etc., complete as per specifications., | Nos | 550.0 | 550.0 | 6.0 | False | None | None | False | None | False | 3300.0 | 0 |
3845346 | 146735 | None | code457 | Providing supplying and fixing ss door handle set (22mm dia 300mm long ) including cost of materials,labour etc., complete as per specifications., | Nos | 1550.0 | 1550.0 | 6.0 | False | None | None | False | None | False | 9300.0 | 0 |
3845347 | 146735 | None | code458 | Providing supplying and fixing Hydraulic door closures with mounting heavy duty shuitable for flush door shutters including cost of materials,labour etc., complete as per specifications., | Nos | 1350.0 | 1350.0 | 20.0 | False | None | None | False | None | False | 27000.0 | 0 |
3845348 | 146735 | None | code459 | Providing supplying and fixing SS but hinges for fixing door shutter to frame for flush door shutters including cost of materials,labour etc., complete as per specifications., | Nos | 375.0 | 375.0 | 30.0 | False | None | None | False | None | False | 11250.0 | 0 |
3845349 | 146735 | None | code460 | Providing supplying and fixing SS screws-25mm for fixing door shutter to frame for flush door shutters including cost of materials,labour etc., complete as per specifications., | Nos | 4.0 | 4.0 | 180.0 | False | None | None | False | None | False | 720.0 | 0 |
3845350 | 146735 | None | code461 | Providing supplying and fixing MS Holdfast of size 260mm x 25mm x 5mm thk for fixing door frames to walls, including cost of materials cutting masonry pockets for receiving ms holdfasts one coat of shop primer,concrete filling of pockets,desposal of debries, including cost of materials,labour etc., complete as per specifications., | Nos | 45.0 | 45.0 | 24.0 | False | None | None | False | None | False | 1080.0 | 0 |
3845351 | 146735 | None | code462 | Supplying, installing, testing and commissioning approved make15 mm CP health faucet of approved make with necessary CP flexible hose 1.0m long nozzle, CP crutch,nozzle anguler stop cock with wall flange etc., complete.make: Jaguar,modle no. ALD-573 | Nos | 1307.0 | 1307.0 | 15.0 | False | None | None | False | None | False | 19605.0 | 0 |
3845352 | 146735 | None | code463 | Supplying, installing and testing Soap Dish including necessary fixing materials etc., complete. (Jal,Jaquar or equivalent) | Nos | 126.0 | 126.0 | 25.0 | False | None | None | False | None | False | 3150.0 | 0 |
3845353 | 146735 | None | code464 | Forming horizontal or vertical grooves on uniform size 10 mm wide and 7 mm deep at junction of wall and column / beam and finishing the grooves to elevation etc, including cost of materials , labour flor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incindental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.per the instructions of the Engineer in charge. (All floors)-Front side Elevation | m | 31.0 | 31.0 | 1300.0 | False | None | None | False | None | False | 40300.0 | 0 |
3845354 | 146735 | None | code465 | Forming horizontal or vertical grooves on uniform size 10 mm wide and 7 mm deep at junction of wall and column / beam and finishing the grooves to elevation etc, including cost of materials , labour flor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incindental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.per the instructions of the Engineer in charge. (All floors)-Front side Elevation | m | 31.0 | 31.0 | 300.0 | False | None | None | False | None | False | 9300.0 | 0 |
3845355 | 146735 | None | code466 | Forming horizontal or vertical grooves on uniform size 10 mm wide and 7 mm deep at junction of wall and column / beam and finishing the grooves to elevation etc, including cost of materials , labour flor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incindental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.per the instructions of the Engineer in charge. (All floors)-top parapet wall | m | 31.0 | 31.0 | 600.0 | False | None | None | False | None | False | 18600.0 | 0 |
3845356 | 146735 | None | code467 | MOULDING : Providing 200 mm height architectural moulding with three stepswith 50mm on top and bottom and 100 mm middle champhered steps in standard architectural methods of execution running on thre edge of the slab, canopy and other places as shown in the drawings or as per the instructions given. the rate includes, materials, labour and complete.-elevation slope | m | 1800.0 | 1800.0 | 300.0 | False | None | None | False | None | False | 540000.0 | 0 |
3845357 | 146735 | None | code468 | Supplying fixing,testing, and commisioning of solar water heating system suitable/designed for "forced circulation" with solar panels hot water storage tank with supporting brackets etc complete. The solar water heater shall consists of the following
Capacity : 200 LPD SS body
solar panel with copper collectors SS body
Bottom insulation of solar panel with 100 microns laminated with rock wool of 48kg/cum density
Support structure made out of polyster powder coated CR tubes
1 No. Air release/vaccum release safty valve with a ball valve of 20mm dia.
Uniform out put on continous usage.
intel and outlet provision.
Necessary interconnecting piping between panel to staorage tank etc. | Nos | 78000.0 | 78000.0 | 1.0 | False | None | None | False | None | False | 78000.0 | 0 |