createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1724400411575
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd895000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose06-09-2024 16:00:00
tenderQueryClose28-08-2024 16:00:00
technicalBidOpen09-09-2024 16:00:00
publishedDate23-08-2024 16:57:58
publishedByPostKHB_EE_CO_BNG
publishedByUserKPE11677 - SHIVASHANKARAPPA K H
bidValidityPeriod180
noOfCalls1
preBidMeetingDate29-08-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVASHANKARAPPA K H
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1724400411596
version7
createdDateNone
modifiedDateNone
tenderNumberKHB/2024-25/BD/WORK_INDENT255
titleConstruction of Rani Abbakka Bhavana in Sy No.82/1A, 2P4 of Permannur Village, Thokkottu, Ullala, Mangaluru, Dakshina Kannada District
descriptionConstruction of Rani Abbakka Bhavana in Sy No.82/1A, 2P4 of Permannur Village, Thokkottu, Ullala, Mangaluru, Dakshina Kannada District
categoryWORKS
categoryTextWorks
ecv59667642.86
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount59667643.0
groupOverheadTotalNone
fileNumber210/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17244004120001NoneNoneBuildingsConstruction of Rani Abbakka Bhavana in Sy No.82/1A, 2P4 of Permannur Village, Thokkottu, Ullala, Mangaluru, Dakshina Kannada District59667642.86
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3844890146735Nonecode01BUILDING CIVIL WORK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.-By Mechanical Means using Dozer-In area of thorny jungle. 100 SqmSqm542.08542.0816.9FalseNoneNoneFalseNoneFalse9161.1520
3844891146735Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m-Cum114.24114.243312.6FalseNoneNoneFalseNoneFalse378431.4240
3844892146735Nonecode03Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth.Cum406.56406.56414.08FalseNoneNoneFalseNoneFalse168348.36480
3844893146735Nonecode04Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m.Cum271.04271.04414.08FalseNoneNoneFalseNoneFalse112232.24320
3844894146735Nonecode05Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm132.16132.16684.0FalseNoneNoneFalseNoneFalse90397.440
3844895146735Nonecode06Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.Cum3003.843003.8489.4654FalseNoneNoneFalseNoneFalse268739.7471360
3844896146735Nonecode07Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-Cum6992.166992.1678.19FalseNoneNoneFalseNoneFalse546716.99040
3844897146735Nonecode08Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-P-15Cum7664.037664.03227.16FalseNoneNoneFalseNoneFalse1740961.05480
3844898146735Nonecode09Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Cum12063.7412063.7420.16FalseNoneNoneFalseNoneFalse243204.99840
3844899146735Nonecode10Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Cum8430.588430.5897.31FalseNoneNoneFalseNoneFalse820379.73980
3844900146735Nonecode11Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Cum11496.2411496.2420.19FalseNoneNoneFalseNoneFalse232109.08560
3844901146735Nonecode12Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-Cum297.92297.92937.46FalseNoneNoneFalseNoneFalse279288.08320
3844902146735Nonecode13Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work.Cum95.295.23203.29FalseNoneNoneFalseNoneFalse304953.2080
3844903146735Nonecode14Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)-Cum7155.687155.6840.05FalseNoneNoneFalseNoneFalse286584.9840
3844904146735Nonecode15Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-Cum6992.166992.162.67FalseNoneNoneFalseNoneFalse18669.06720
3844905146735Nonecode16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates--LOWER GROUND FLOORCum13029.0713029.0761.07FalseNoneNoneFalseNoneFalse795685.30490
3844906146735Nonecode17Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates--UPPER GROUND FLOORCum13029.0713029.0738.48FalseNoneNoneFalseNoneFalse501358.61360
3844907146735Nonecode18Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates--FIRST FLOOR (BALCONY LEVEL)Cum13159.3613159.3636.17FalseNoneNoneFalseNoneFalse475974.05120
3844908146735Nonecode19Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates--SECOND FLOORCum13289.6513289.6527.45FalseNoneNoneFalseNoneFalse364800.89250
3844909146735Nonecode20Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates--TERRACE FLOORCum13419.9413419.946.93FalseNoneNoneFalseNoneFalse93000.18420
3844910146735Nonecode21Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates--TERRACE FLOORCum12192.2812192.2811.66FalseNoneNoneFalseNoneFalse142161.98480
3844911146735Nonecode22Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC LINTEL--LOWER GROUND FLOORCum12262.6612262.660.31FalseNoneNoneFalseNoneFalse3801.42460
3844912146735Nonecode23Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC LINTEL--UPPER GROUND FLOORCum12262.6612262.667.61FalseNoneNoneFalseNoneFalse93318.84260
3844913146735Nonecode24Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC LINTEL--FIRST FLOOR (BALCONY LEVEL)Cum12385.2812385.286.16FalseNoneNoneFalseNoneFalse76293.32480
3844914146735Nonecode25Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC LINTEL--SECOND FLOORCum12507.9112507.914.4FalseNoneNoneFalseNoneFalse55034.8040
3844915146735Nonecode26Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC LINTEL--TERRACE FLOORCum12630.5412630.541.1FalseNoneNoneFalseNoneFalse13893.5940
3844916146735Nonecode27Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-LOWER GROUND FLOORCum10138.6310138.630.31FalseNoneNoneFalseNoneFalse3142.97530
3844917146735Nonecode28Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-UPPER GROUND FLOORCum10138.6310138.633.81FalseNoneNoneFalseNoneFalse38628.18030
3844918146735Nonecode29Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-FIRST FLOOR (BALCONY LEVEL)Cum10240.0210240.023.08FalseNoneNoneFalseNoneFalse31539.26160
3844919146735Nonecode30Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-SECOND FLOORCum10341.410341.42.2FalseNoneNoneFalseNoneFalse22751.080
3844920146735Nonecode31Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-TERRACE FLOORCum10442.7910442.790.55FalseNoneNoneFalseNoneFalse5743.53450
3844921146735Nonecode32Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC STAIRCASE-LOWER GROUND FLOORCum11496.2411496.244.45FalseNoneNoneFalseNoneFalse51158.2680
3844922146735Nonecode33Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC STAIRCASE-UPPER GROUND FLOORCum11496.2411496.2419.09FalseNoneNoneFalseNoneFalse219463.22160
3844923146735Nonecode34Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC STAIRCASE-FIRST FLOOR(BALCONY LEVEL)Cum11611.211611.29.34FalseNoneNoneFalseNoneFalse108448.6080
3844924146735Nonecode35Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC STAIRCASE-SECOND FLOORCum11726.1611726.164.45FalseNoneNoneFalseNoneFalse52181.4120
3844925146735Nonecode36Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC BEAM-LOWER GROUND FLOORCum12262.6612262.6657.66FalseNoneNoneFalseNoneFalse707064.97560
3844926146735Nonecode37Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC BEAM-UPPER GROUND FLOORCum12262.6612262.6641.51FalseNoneNoneFalseNoneFalse509023.01660
3844927146735Nonecode38Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC BEAM-FIRST FLOOR (BALCONY LEVEL)Cum12385.2812385.2838.87FalseNoneNoneFalseNoneFalse481415.83360
3844928146735Nonecode39Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC BEAM-SECOND FLOORCum12507.9112507.9146.85FalseNoneNoneFalseNoneFalse585995.58350
3844929146735Nonecode40Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC BEAM-TERRACE FLOORCum12630.5412630.544.06FalseNoneNoneFalseNoneFalse51279.99240
3844930146735Nonecode41Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC SLAB-LOWER GROUND FLOORCum11496.2411496.2489.6FalseNoneNoneFalseNoneFalse1030063.1040
3844931146735Nonecode42Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC SLAB--UPPER GROUND FLOORCum11496.2411496.2463.55FalseNoneNoneFalseNoneFalse730586.0520
3844932146735Nonecode43Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC SLAB--FIRST FLOOR(BALCONY LEVEL)Cum11611.211611.252.3FalseNoneNoneFalseNoneFalse607265.760
3844933146735Nonecode44Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC SLAB--SECOND FLOORCum11726.1611726.1611.89FalseNoneNoneFalseNoneFalse139424.04240
3844934146735Nonecode45Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC SLAB--TERRACE FLOORCum11841.1311841.136.0FalseNoneNoneFalseNoneFalse71046.780
3844935146735Nonecode46Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC CHAJJA-GROUND FLOORCum11113.0311113.034.22FalseNoneNoneFalseNoneFalse46896.98660
3844936146735Nonecode47Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC CHAJJA-FIRST FLOOR(BALCONY LEVEL)Cum11224.1611224.162.53FalseNoneNoneFalseNoneFalse28397.12480
3844937146735Nonecode48Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC CHAJJA-SECOND FLOORCum11335.2911335.293.85FalseNoneNoneFalseNoneFalse43640.86650
3844938146735Nonecode49Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.-GROUND FLOORSqm1386.561386.564.22FalseNoneNoneFalseNoneFalse5851.28320
3844939146735Nonecode50Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.-FIRST FLOORSqm1400.431400.432.53FalseNoneNoneFalseNoneFalse3543.08790
3844940146735Nonecode51Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.-SECOND FLOORSqm1414.291414.293.85FalseNoneNoneFalseNoneFalse5445.01650
3844941146735Nonecode52Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a) Buildings-Tonne100191.84100191.84125.19FalseNoneNoneFalseNoneFalse12543016.44960
3844942146735Nonecode53Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.-UPPER GROUNDCum2259.042259.0463.88FalseNoneNoneFalseNoneFalse144307.47520
3844943146735Nonecode54Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.-FIRST FLOOR(BALCONY LEVEL)Cum2281.632281.6332.2FalseNoneNoneFalseNoneFalse73468.4860
3844944146735Nonecode55Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.-SECOND FLOORCum2304.222304.225.63FalseNoneNoneFalseNoneFalse12972.75860
3844945146735Nonecode56Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates-UPPER GROUNDCum6963.046963.0423.95FalseNoneNoneFalseNoneFalse166764.8080
3844946146735Nonecode57Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates-FIRST FLOOR(BALCONY LEVEL)Cum7032.677032.6712.07FalseNoneNoneFalseNoneFalse84884.32690
3844947146735Nonecode58Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates-SECOND FLOORCum7102.37102.32.11FalseNoneNoneFalseNoneFalse14985.8530
3844948146735Nonecode59Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-UPPER GROUNDSqm415.52415.5216.22FalseNoneNoneFalseNoneFalse6739.73440
3844949146735Nonecode60Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-FIRST FLOOR(BALCONY LEVEL)Sqm419.68419.68160.99FalseNoneNoneFalseNoneFalse67564.28320
3844950146735Nonecode61Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-SECOND FLOORSqm423.83423.8328.17FalseNoneNoneFalseNoneFalse11939.29110
3844951146735Nonecode62Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.-LOWER GROUND FLOORCum7565.67565.64.89FalseNoneNoneFalseNoneFalse36995.7840
3844952146735Nonecode63Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.--UPPER GROUND FLOORCum7565.67565.6137.07FalseNoneNoneFalseNoneFalse1037016.7920
3844953146735Nonecode64Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.--FIRST FLOOR(BALCONY LEVEL)Cum7641.267641.26104.95FalseNoneNoneFalseNoneFalse801950.2370
3844954146735Nonecode65Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.--SECOND FLOORCum7716.917716.91104.95FalseNoneNoneFalseNoneFalse809889.70450
3844955146735Nonecode66Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.--TERRACE FLOORCum7792.577792.5720.87FalseNoneNoneFalseNoneFalse162630.93590
3844956146735Nonecode67Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.GROUND FLOORSqm1467.21467.263.9FalseNoneNoneFalseNoneFalse93754.080
3844957146735Nonecode68Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-FIRST FLOOR(BALCONY LEVEL)Sqm1481.871481.8763.9FalseNoneNoneFalseNoneFalse94691.4930
3844958146735Nonecode69Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-SECOND FLOORSqm1496.541496.5441.4FalseNoneNoneFalseNoneFalse61956.7560
3844959146735Nonecode70Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.TERRACE FLOORSqm1511.221511.2230.9FalseNoneNoneFalseNoneFalse46696.6980
3844960146735Nonecode71Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.--GROUND FLOORSqm1378.721378.7238.82FalseNoneNoneFalseNoneFalse53521.91040
3844961146735Nonecode72Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-FIRST FLOOR (BALCONY LEVEL)Sqm1392.511392.5131.95FalseNoneNoneFalseNoneFalse44490.69450
3844962146735Nonecode73Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-SECOND FLOORSqm1406.291406.2923.52FalseNoneNoneFalseNoneFalse33075.94080
3844963146735Nonecode74Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-TERRACE FLOORSqm1420.081420.0823.52FalseNoneNoneFalseNoneFalse33400.28160
3844964146735Nonecode75Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.--GROUND FLOORSqm1236.481236.4867.47FalseNoneNoneFalseNoneFalse83425.30560
3844965146735Nonecode76Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.--FIRST FLOOR (BALCONY LEVEL)Sqm1248.841248.8450.13FalseNoneNoneFalseNoneFalse62604.34920
3844966146735Nonecode77Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.--SECOND FLOORSqm1261.211261.212.35FalseNoneNoneFalseNoneFalse2963.84350
3844967146735Nonecode78Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.--TERRACE FLOORSqm1273.571273.57135.3FalseNoneNoneFalseNoneFalse172314.0210
3844968146735Nonecode79Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Sl.No 12.11, Page No.99, Volume- II, GROUND FLOOR.Cum154642.88154642.880.98FalseNoneNoneFalseNoneFalse151550.02240
3844969146735Nonecode80Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications--LOWER GROUND FLOORCum111552.0111552.00.12FalseNoneNoneFalseNoneFalse13386.240
3844970146735Nonecode81Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications--UPPER GROUND FLOORCum111552.0111552.01.15FalseNoneNoneFalseNoneFalse128284.80
3844971146735Nonecode82Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications--FIRST FLOOR ( BALCONY LEVEL)Cum112667.52112667.521.15FalseNoneNoneFalseNoneFalse129567.6480
3844972146735Nonecode83Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications--SECOND FLOORCum113783.04113783.041.15FalseNoneNoneFalseNoneFalse130850.4960
3844973146735Nonecode84Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications--TERRACE FLOORCum114898.56114898.560.1FalseNoneNoneFalseNoneFalse11489.8560
3844974146735Nonecode85Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.UPPER GROUND FLOORm720.16720.1638.4FalseNoneNoneFalseNoneFalse27654.1440
3844975146735Nonecode86Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.FIRST FLOOR (BALCONY LEVEL)m727.36727.3632.0FalseNoneNoneFalseNoneFalse23275.520
3844976146735Nonecode87Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.-SECOND FLOORm734.56734.566.4FalseNoneNoneFalseNoneFalse4701.1840
3844977146735Nonecode88Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-LOWER GROUND FLOORSqm7542.087542.083.6FalseNoneNoneFalseNoneFalse27151.4880
3844978146735Nonecode89Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-UPPER GROUND FLOORSqm7542.087542.0893.42FalseNoneNoneFalseNoneFalse704581.11360
3844979146735Nonecode90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-FIRST FLOOR (BALCONY LEVEL)Sqm7617.57617.571.82FalseNoneNoneFalseNoneFalse547088.850
3844980146735Nonecode91Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-SECOND FLOORSqm7692.927692.9218.9FalseNoneNoneFalseNoneFalse145396.1880
3844981146735Nonecode92Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOORSqm7768.347768.342.43FalseNoneNoneFalseNoneFalse18877.06620
3844982146735Nonecode93Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- -LOER GROUNDSqm6405.286405.2813.05FalseNoneNoneFalseNoneFalse83588.9040
3844983146735Nonecode94Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- -UPPER GROUND FLOORSqm6405.286405.2813.05FalseNoneNoneFalseNoneFalse83588.9040
3844984146735Nonecode95Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- -FIRST FLOOR (BALCONY LEVEL)Sqm6469.336469.335.13FalseNoneNoneFalseNoneFalse33187.66290
3844985146735Nonecode96Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- SECOND FLOORSqm6533.396533.392.97FalseNoneNoneFalseNoneFalse19404.16830
3844986146735Nonecode97Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.-UPPER GROUND FLOORSqm8906.248906.246.0FalseNoneNoneFalseNoneFalse53437.440
3844987146735Nonecode98Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.\FIRST FLOOR(BALCONYLEVEL)Sqm8995.38995.36.0FalseNoneNoneFalseNoneFalse53971.80
3844988146735Nonecode99Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.SECOND FLOORSqm9084.369084.366.0FalseNoneNoneFalseNoneFalse54506.160
3844989146735Nonecode100Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) Sl. No. 12.20 Page No. 100, Volume-II -UPPER GROUND FLOORSqm6888.06888.013.23FalseNoneNoneFalseNoneFalse91128.240
3844990146735Nonecode101Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial-LOWER GROUND FLOORSqm3720.643720.642.57FalseNoneNoneFalseNoneFalse9562.04480
3844991146735Nonecode102Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial-UPPER GROUND FLOORSqm3720.643720.6424.82FalseNoneNoneFalseNoneFalse92346.28480
3844992146735Nonecode103Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercialFIRST FLOOR (BALCONY LEVEL)Sqm3757.853757.858.13FalseNoneNoneFalseNoneFalse30551.32050
3844993146735Nonecode104Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial-SECOND FLOORSqm3795.053795.055.15FalseNoneNoneFalseNoneFalse19544.50750
3844994146735Nonecode105Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial-TERRACE FLOORSqm3832.263832.262.94FalseNoneNoneFalseNoneFalse11266.84440
3844995146735Nonecode106Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.- 30 mm thickness--UPPER GROUND FLOORSqm3588.483588.489.68FalseNoneNoneFalseNoneFalse34736.48640
3844996146735Nonecode107Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.- 30 mm thickness-FIRST FLOOR (BALCONY LEVEL)Sqm3624.363624.369.68FalseNoneNoneFalseNoneFalse35083.80480
3844997146735Nonecode108Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.- 30 mm thickness-SECOND FLOORSqm3660.253660.253.23FalseNoneNoneFalseNoneFalse11822.60750
3844998146735Nonecode109Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge.TERRACE FLOORSqm5165.825165.822.45FalseNoneNoneFalseNoneFalse12656.2590
3844999146735Nonecode110Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.-GROUND FLOORNos1137.921137.929.0FalseNoneNoneFalseNoneFalse10241.280
3845000146735Nonecode111Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.--SECOND FLOORNos1149.31149.312.0FalseNoneNoneFalseNoneFalse13791.60
3845001146735Nonecode112Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.-SECOND FLOORNos1160.681160.6811.0FalseNoneNoneFalseNoneFalse12767.480
3845002146735Nonecode113Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.--TERRACE FLOORNos1172.061172.061.0FalseNoneNoneFalseNoneFalse1172.060
3845003146735Nonecode114Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos134.4134.466.0FalseNoneNoneFalseNoneFalse8870.40
3845004146735Nonecode115Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete-Nos1178.241178.2466.0FalseNoneNoneFalseNoneFalse77763.840
3845005146735Nonecode116Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete-Nos265.44265.4466.0FalseNoneNoneFalseNoneFalse17519.040
3845006146735Nonecode117Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm,Nos487.2487.266.0FalseNoneNoneFalseNoneFalse32155.20
3845007146735Nonecode118Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :-125x85x5.5mm.(heavy type) Sl.no-12.75.1, pg.no-107,volume-2.Nos308.0308.0496.0FalseNoneNoneFalseNoneFalse152768.00
3845008146735Nonecode119Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :-100x85x5.5mm.(heavy type) Sl.no-12.75.3, pg.no-107,volume-2.Nos229.6229.681.0FalseNoneNoneFalseNoneFalse18597.60
3845009146735Nonecode120Providing and fixing MS Hold fasts (SL. No 444,Page No.A-25, Basic Rate Rs. 50.00), volume-2.Each56.056.0198.0FalseNoneNoneFalseNoneFalse11088.00
3845010146735Nonecode121Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms-SL.NO-12.64, PG.NO-105,VOLUME-2.Nos61.661.660.0FalseNoneNoneFalseNoneFalse3696.00
3845011146735Nonecode122Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding,-LOWER GROUND FLOORKg188.16188.1664.8FalseNoneNoneFalseNoneFalse12192.7680
3845012146735Nonecode123Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding,-UPPER GROUND FLOORKg188.16188.161681.56FalseNoneNoneFalseNoneFalse316402.32960
3845013146735Nonecode124Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding,-FIRST FLOOR (BALCONY LEVEL)Kg190.04190.041292.76FalseNoneNoneFalseNoneFalse245676.11040
3845014146735Nonecode125Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding,-SECOND FLOORKg191.92191.92340.2FalseNoneNoneFalseNoneFalse65291.1840
3845015146735Nonecode126Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding,-TERRACE FLOORKg193.8193.8291.6FalseNoneNoneFalseNoneFalse56512.080
3845016146735Nonecode127Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of EngineerIn-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.LOWER GROUND FLOORSqm361.76361.76597.36FalseNoneNoneFalseNoneFalse216100.95360
3845017146735Nonecode128Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-UPPER GROUND FLOORSqm361.76361.76732.36FalseNoneNoneFalseNoneFalse264938.55360
3845018146735Nonecode129Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-FIRST FLOOR (BALCONY LEVEL)Sqm365.38365.381056.1FalseNoneNoneFalseNoneFalse385877.8180
3845019146735Nonecode130Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-SECOND FLOORSqm369.0369.0402.5FalseNoneNoneFalseNoneFalse148522.50
3845020146735Nonecode131Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-TERRACE FLOORSqm372.61372.6157.55FalseNoneNoneFalseNoneFalse21443.70550
3845021146735Nonecode132Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-LOWER GROUND FLOORSqm361.76361.76119.47FalseNoneNoneFalseNoneFalse43219.46720
3845022146735Nonecode133Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-UPPER GROUND FLOORSqm361.76361.76146.47FalseNoneNoneFalseNoneFalse52986.98720
3845023146735Nonecode134Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-FIRST FLOOR (BALCONY LEVEL)Sqm365.38365.38211.22FalseNoneNoneFalseNoneFalse77175.56360
3845024146735Nonecode135Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-SECOND FLOORSqm369.0369.080.5FalseNoneNoneFalseNoneFalse29704.50
3845025146735Nonecode136Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-TERRACE FLOORSqm372.61372.6111.51FalseNoneNoneFalseNoneFalse4288.74110
3845026146735Nonecode137Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide-LOWER GROUND FLOORSqm42.5642.56477.89FalseNoneNoneFalseNoneFalse20338.99840
3845027146735Nonecode138Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide-UPPER GROUND FLOORSqm42.5642.56585.89FalseNoneNoneFalseNoneFalse24935.47840
3845028146735Nonecode139Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide-FIRST FLOOR (BALCONY LEVEL)Sqm42.9942.99844.88FalseNoneNoneFalseNoneFalse36321.39120
3845029146735Nonecode140Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide-SECOND FLOORSqm43.4143.41322.0FalseNoneNoneFalseNoneFalse13978.020
3845030146735Nonecode141Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide-TERRACE FLOORSqm43.8443.8446.04FalseNoneNoneFalseNoneFalse2018.39360
3845031146735Nonecode142Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2.-LOWER GROUND FLOORSqm409.92409.92493.63FalseNoneNoneFalseNoneFalse202348.80960
3845032146735Nonecode143Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2.UPPER GROUND FLOORSqm409.92409.92994.67FalseNoneNoneFalseNoneFalse407735.12640
3845033146735Nonecode144Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2.-FIRST FLOOR (BALCONY LEVEL)Sqm414.02414.021008.36FalseNoneNoneFalseNoneFalse417481.20720
3845034146735Nonecode145Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2.-SECOND FLOORSqm418.12418.12951.62FalseNoneNoneFalseNoneFalse397891.35440
3845035146735Nonecode146Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2.-TERRACE FLOORSqm422.22422.2268.9FalseNoneNoneFalseNoneFalse29090.9580
3845036146735Nonecode147Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41, Volume- 2.-UPPER GROUND FLOORSqm330.4330.4156.84FalseNoneNoneFalseNoneFalse51819.9360
3845037146735Nonecode148Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41, Volume- 2.-FIRST FLOOR (BALCONY LEVEL)Sqm333.7333.7106.77FalseNoneNoneFalseNoneFalse35629.1490
3845038146735Nonecode149Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41, Volume- 2.-SECOND FLOORSqm337.01337.0116.08FalseNoneNoneFalseNoneFalse5419.12080
3845039146735Nonecode150Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.-LOWER GROUND FLOORSqm431.2431.2499.5FalseNoneNoneFalseNoneFalse215384.40
3845040146735Nonecode151Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.-UPPER GROUND FLOORSqm431.2431.2545.0FalseNoneNoneFalseNoneFalse235004.00
3845041146735Nonecode152Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.FIRST FLOOR (BALCONY LEVEL)Sqm435.51435.51548.5FalseNoneNoneFalseNoneFalse238877.2350
3845042146735Nonecode153Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.-SECOND FLOORSqm439.82439.82514.2FalseNoneNoneFalseNoneFalse226155.4440
3845043146735Nonecode154Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.-TERRACE FLOORSqm444.14444.14343.0FalseNoneNoneFalseNoneFalse152340.020
3845044146735Nonecode155Providing ruled pointing to coursed stone masonry with lime mortar 1:3, 20mm deep, after raking joints to depth of 20mm nicely lining, including cost all materials, labour, usage charges of machinery, curing complete as per specification.-GROUND FLOORSqm334.88334.88121.0FalseNoneNoneFalseNoneFalse40520.480
3845045146735Nonecode156Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-Page 15, Sl. No.2.1.6, Volume-I-LOWER GROUND FLOORCum6992.166992.1669.5FalseNoneNoneFalseNoneFalse485955.120
3845046146735Nonecode157Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.-GROUND FLOORSqm3194.243194.24666.43FalseNoneNoneFalseNoneFalse2128737.36320
3845047146735Nonecode158Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.-FIRST FLOOR (BALCONY LEVEL)Sqm3226.183226.18287.91FalseNoneNoneFalseNoneFalse928849.48380
3845048146735Nonecode159Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.SECOND FLOORSqm3258.123258.12134.79FalseNoneNoneFalseNoneFalse439161.99480
3845049146735Nonecode160Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.LOWER GROUND FLOORSqm5967.365967.3630.69FalseNoneNoneFalseNoneFalse183138.27840
3845050146735Nonecode161Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.-UPPER GROUND FLOORSqm5967.365967.36100.6FalseNoneNoneFalseNoneFalse600316.4160
3845051146735Nonecode162Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.-FIRST FLOOR (BALCONY LEVEL)Sqm6027.036027.0357.29FalseNoneNoneFalseNoneFalse345288.54870
3845052146735Nonecode163Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete-GROUND FLOORSqm3762.083762.0858.5FalseNoneNoneFalseNoneFalse220081.680
3845053146735Nonecode164Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete-FIRST FLOORSqm3799.73799.745.0FalseNoneNoneFalseNoneFalse170986.50
3845054146735Nonecode165Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., completeSECOND FLOORSqm3837.323837.3245.0FalseNoneNoneFalseNoneFalse172679.40
3845055146735Nonecode166Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..-- Size of Tile 600x600 mm-LOWER GROUND FLOORSqm1282.41282.46.36FalseNoneNoneFalseNoneFalse8156.0640
3845056146735Nonecode167Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..-- Size of Tile 600x600 mm-UPPER GROUND FLOORSqm1282.41282.460.34FalseNoneNoneFalseNoneFalse77380.0160
3845057146735Nonecode168Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..-- Size of Tile 600x600 mm-FIRST FLOOR (BALCONY LEVEL)Sqm1295.221295.2235.1FalseNoneNoneFalseNoneFalse45462.2220
3845058146735Nonecode169Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..-- Size of Tile 600x600 mmSECOND FLOORSqm1308.051308.0566.15FalseNoneNoneFalseNoneFalse86527.50750
3845059146735Nonecode170Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71, Volume-2.-UPPER GROUND FLOORSqm1238.721238.72156.84FalseNoneNoneFalseNoneFalse194280.84480
3845060146735Nonecode171Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71, Volume-2.-FIRST FLOORSqm1251.111251.11106.77FalseNoneNoneFalseNoneFalse133581.01470
3845061146735Nonecode172Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71, Volume-2.-SECOND FLOORSqm1263.491263.4916.08FalseNoneNoneFalseNoneFalse20316.91920
3845062146735Nonecode173Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.-UPPER GROUND FLOORSqm1205.121205.1219.34FalseNoneNoneFalseNoneFalse23307.02080
3845063146735Nonecode174Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.-FIRST FLOOR (BALCONY LEVEL)Sqm1217.171217.1722.74FalseNoneNoneFalseNoneFalse27678.44580
3845064146735Nonecode175Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.-SECOND FLOORSqm1229.221229.223.47FalseNoneNoneFalseNoneFalse4265.39340
3845065146735Nonecode176Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.-UPPER GROUND FLOORSqm4792.484792.4810.1FalseNoneNoneFalseNoneFalse48404.0480
3845066146735Nonecode177Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.-FIRST FLOOR (BALCONY LEVEL)Sqm4840.44840.47.56FalseNoneNoneFalseNoneFalse36593.4240
3845067146735Nonecode178Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.-SECOND FLOORSqm4888.334888.331.2FalseNoneNoneFalseNoneFalse5865.9960
3845068146735Nonecode179Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2..-UPPER GROUND FLOORSqm112.0112.01434.62FalseNoneNoneFalseNoneFalse160677.440
3845069146735Nonecode180Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2..-GROUND FLOORSqm112.0112.01873.5FalseNoneNoneFalseNoneFalse209832.00
3845070146735Nonecode181Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2..-FIRST FLOORSqm113.12113.122275.68FalseNoneNoneFalseNoneFalse257424.92160
3845071146735Nonecode182Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2..-SECOND FLOORSqm114.24114.241434.62FalseNoneNoneFalseNoneFalse163890.98880
3845072146735Nonecode183Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2..-TERRACE FLOORSqm115.36115.36137.96FalseNoneNoneFalseNoneFalse15915.06560
3845073146735Nonecode184Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.-UPPER GROUND FLOORSqm176.96176.96402.5FalseNoneNoneFalseNoneFalse71226.40
3845074146735Nonecode185Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.-GROUND FLOORSqm176.96176.96732.36FalseNoneNoneFalseNoneFalse129598.42560
3845075146735Nonecode186Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.-FIRST FLOORSqm178.73178.731056.1FalseNoneNoneFalseNoneFalse188756.7530
3845076146735Nonecode187Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.-SECOND FLOORSqm180.5180.5402.5FalseNoneNoneFalseNoneFalse72651.250
3845077146735Nonecode188Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.-TERRACE FLOORSqm182.27182.2757.55FalseNoneNoneFalseNoneFalse10489.63850
3845078146735Nonecode189Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)-UPPER GROUND FLOORSqm176.96176.96951.62FalseNoneNoneFalseNoneFalse168398.67520
3845079146735Nonecode190Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)-GROUND FLOORSqm176.96176.96994.67FalseNoneNoneFalseNoneFalse176016.80320
3845080146735Nonecode191Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)-FIRST FLOORSqm178.73178.731008.36FalseNoneNoneFalseNoneFalse180224.18280
3845081146735Nonecode192Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)-SECOND FLOORSqm180.5180.5951.62FalseNoneNoneFalseNoneFalse171767.410
3845082146735Nonecode193Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)-TERRACE FLOORSqm182.27182.2768.9FalseNoneNoneFalseNoneFalse12558.4030
3845083146735Nonecode194Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-UPPER GROUND FLOORSqm316.96316.9677.13FalseNoneNoneFalseNoneFalse24447.12480
3845084146735Nonecode195Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-GROUND FLOORSqm316.96316.9681.75FalseNoneNoneFalseNoneFalse25911.480
3845085146735Nonecode196Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-FIRST FLOORSqm320.13320.1382.28FalseNoneNoneFalseNoneFalse26340.29640
3845086146735Nonecode197Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-SECOND FLOORSqm323.3323.377.13FalseNoneNoneFalseNoneFalse24936.1290
3845087146735Nonecode198Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-TERRACE FLOORSqm326.47326.4734.3FalseNoneNoneFalseNoneFalse11197.9210
3845088146735Nonecode199Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2.-UPPER GROUND FLOORSqm194.88194.88411.36FalseNoneNoneFalseNoneFalse80165.83680
3845089146735Nonecode200Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2.-GROUND FLOORSqm194.88194.88436.0FalseNoneNoneFalseNoneFalse84967.680
3845090146735Nonecode201Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2.-FIRST FLOORSqm196.83196.83438.8FalseNoneNoneFalseNoneFalse86369.0040
3845091146735Nonecode202Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2.-SECOND FLOORSqm198.78198.78411.36FalseNoneNoneFalseNoneFalse81770.14080
3845092146735Nonecode203Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2.-TERRACE FLOORSqm200.73200.73274.4FalseNoneNoneFalseNoneFalse55080.3120
3845093146735Nonecode204Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2.-LOWER GROUND FLOORSqm187.04187.047.2FalseNoneNoneFalseNoneFalse1346.6880
3845094146735Nonecode205Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2.-GROUND FLOORSqm187.04187.04186.84FalseNoneNoneFalseNoneFalse34946.55360
3845095146735Nonecode206Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2.-FIRST FLOORSqm188.91188.91143.64FalseNoneNoneFalseNoneFalse27135.03240
3845096146735Nonecode207Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2.-SECOND FLOORSqm190.78190.7837.8FalseNoneNoneFalseNoneFalse7211.4840
3845097146735Nonecode208Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2.-TERRACE FLOORSqm192.65192.656.08FalseNoneNoneFalseNoneFalse1171.3120
3845098146735Nonecode209Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.50, Volume-2.-LOWER GROUND FLOORSqm62.7262.726.43FalseNoneNoneFalseNoneFalse403.28960
3845099146735Nonecode210Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.50, Volume-2.-GROUND FLOORSqm62.7262.7295.12FalseNoneNoneFalseNoneFalse5965.92640
3845100146735Nonecode211Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.50, Volume-2.-FIRST FLOORSqm63.3563.3520.34FalseNoneNoneFalseNoneFalse1288.5390
3845101146735Nonecode212Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.50, Volume-2.-SECOND FLOORSqm63.9763.9720.21FalseNoneNoneFalseNoneFalse1292.83370
3845102146735Nonecode213Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49,volume-2.-GROUND FLOORSqm151.2151.295.12FalseNoneNoneFalseNoneFalse14382.1440
3845103146735Nonecode214Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49,volume-2.-FIRST FLOORSqm152.71152.7120.34FalseNoneNoneFalseNoneFalse3106.12140
3845104146735Nonecode215Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49,volume-2.-SECOND FLOORSqm154.22154.2220.21FalseNoneNoneFalseNoneFalse3116.78620
3845105146735Nonecode216Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sl.No 11.28, Page No.85, Volume-2.-LOWER GROUND FLOORKg632.8632.87.56FalseNoneNoneFalseNoneFalse4783.9680
3845106146735Nonecode217Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sl.No 11.28, Page No.85, Volume-2.-UPPER GROUND FLOORKg632.8632.8214.2FalseNoneNoneFalseNoneFalse135545.760
3845107146735Nonecode218Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sl.No 11.28, Page No.85, Volume-2.-FIRST FLOOR (BALCONY LEVEL)Kg639.13639.13212.04FalseNoneNoneFalseNoneFalse135521.12520
3845108146735Nonecode219Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sl.No 11.28, Page No.85, Volume-2.-SECOND FLOORKg645.46645.4645.36FalseNoneNoneFalseNoneFalse29278.06560
3845109146735Nonecode220Providing and fixing ion wall face unplasticised Rigid PVC rain water pipes confirming to IS :13592 Type A,including jointing with seal ring confirming to IS:5382,leaving 10mm gap for thermal expansion,(i) Single socketed pipes 100mm diameter.item no-13.48, volume-2. PG.NO-125.m332.44332.44180.0FalseNoneNoneFalseNoneFalse59839.20
3845110146735Nonecode221Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-chargeSqm896.0896.0184.25FalseNoneNoneFalseNoneFalse165088.00
3845111146735Nonecode222Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates.Cum7102.37102.336.32FalseNoneNoneFalseNoneFalse257955.5360
3845112146735Nonecode223Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specificationSqm915.04915.04396.0FalseNoneNoneFalseNoneFalse362355.840
3845113146735Nonecode224Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm9269.129269.127.5FalseNoneNoneFalseNoneFalse69518.40
3845114146735Nonecode225Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Sqm602.59602.59562.46FalseNoneNoneFalseNoneFalse338932.77140
3845115146735Nonecode226Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top cover-Sqm450.88450.88562.46FalseNoneNoneFalseNoneFalse253601.96480
3845116146735Nonecode227Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coverm1139.411139.4126.04FalseNoneNoneFalseNoneFalse29670.23640
3845117146735Nonecode228Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coverm478.47478.4752.08FalseNoneNoneFalseNoneFalse24918.71760
3845118146735Nonecode229Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg154.44154.445624.64FalseNoneNoneFalseNoneFalse868669.40160
3845119146735Nonecode230Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.Sqm1743.791743.79160.0FalseNoneNoneFalseNoneFalse279006.40
3845120146735Nonecode231PLUMBING AND SANITARY-Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. Sl.No 14.1.1, Page No.131, Volume-IINos5470.085470.0810.0FalseNoneNoneFalseNoneFalse54700.80
3845121146735Nonecode232Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. Sl.No 14.3.1, Page No.131, Volume-IINos6694.246694.245.0FalseNoneNoneFalseNoneFalse33471.20
3845122146735Nonecode233Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. Sl.No 14.7A, Page No.133, Volume-IINos4615.524615.5217.0FalseNoneNoneFalseNoneFalse78463.840
3845123146735Nonecode234Providing and fixing 100 mm sand cast Iron grating for gully trap. Sl.No 14.29, Page No.136, Volume-II.Nos52.6452.6445.0FalseNoneNoneFalseNoneFalse2368.80
3845124146735Nonecode235Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. Sl.No 13.15, Page No.119, Volume-IINos812.0812.050.0FalseNoneNoneFalseNoneFalse40600.00
3845125146735Nonecode236Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g. Sl.No 13.13, Page No.119, Volume-IINos947.52947.5250.0FalseNoneNoneFalseNoneFalse47376.00
3845126146735Nonecode237Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-25 mm nominal boreNos614.88614.883.0FalseNoneNoneFalseNoneFalse1844.640
3845127146735Nonecode238Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-32 mm nominal boreNos669.76669.763.0FalseNoneNoneFalseNoneFalse2009.280
3845128146735Nonecode239Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-40 mm nominal boreNos786.24786.243.0FalseNoneNoneFalseNoneFalse2358.720
3845129146735Nonecode240Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-50 mm nominal boreNos957.6957.63.0FalseNoneNoneFalseNoneFalse2872.80
3845130146735Nonecode241Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-65 mm nominal boreNos1277.921277.923.0FalseNoneNoneFalseNoneFalse3833.760
3845131146735Nonecode242Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-80 mm nominal boreNos2326.242326.242.0FalseNoneNoneFalseNoneFalse4652.480
3845132146735Nonecode243Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Sl.No 14.31, Page No.136, Volume-IINos1368.641368.6415.0FalseNoneNoneFalseNoneFalse20529.60
3845133146735Nonecode244600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Sl.No 14.40.2, Page No.137, Volume-IINos555.52555.5215.0FalseNoneNoneFalseNoneFalse8332.80
3845134146735Nonecode245Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 160mm dia., 6 kg/sqcm & class 3. Sl.No 10.1.9, PG.NO-113, VOLUME-5.m692.16692.16110.0FalseNoneNoneFalseNoneFalse76137.60
3845135146735Nonecode246Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia., 6 kg/sqcm & class 3. Sl.No 10.1.7, PG.NO-113, VOLUME-5.m460.32460.32169.0FalseNoneNoneFalseNoneFalse77794.080
3845136146735Nonecode247Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 90mm dia., 6 kg/sqcm & class 3. Sl.No 10.1.6, PG.NO-113, VOLUME-5.m329.28329.28185.0FalseNoneNoneFalseNoneFalse60916.80
3845137146735Nonecode248Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - 50 mm nominal dia Pipes. Sl.No 13.31.6, PG.NO-122, VOL-2.m874.72874.72105.0FalseNoneNoneFalseNoneFalse91845.60
3845138146735Nonecode249Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 32 mm dia. Sl.No 13.32.4, page-122, VOL-2.m623.84623.8485.0FalseNoneNoneFalseNoneFalse53026.40
3845139146735Nonecode250Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 25 mm dia. Sl.No 13.32.3, page-122, VOL-2.m534.24534.24200.0FalseNoneNoneFalseNoneFalse106848.00
3845140146735Nonecode251Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 20 mm dia. Sl.No 13.32.2, page-122, VOL-2.Nos424.48424.48200.0FalseNoneNoneFalseNoneFalse84896.00
3845141146735Nonecode252Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. Sl.No 16.10,page-191, VOL-5.Nos4744.324744.3210.0FalseNoneNoneFalseNoneFalse47443.20
3845142146735Nonecode253KSRB 11-18-9.1 : Providing and fixing sand cast iron soil waste single equal junction of required degree with access door 100x100x100mm, including cost of materials, labour, testing complete as per specifications. Specification No. KBS 11.1.10,Nos1044.961044.9620.0FalseNoneNoneFalseNoneFalse20899.20
3845143146735Nonecode254Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Sl.No 13.34, page-123, VOL-2.l10.0810.085000.0FalseNoneNoneFalseNoneFalse50400.00
3845144146735Nonecode255Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc, complete. 5.00 HP/3.7KW, 25 STG.Nos29568.029568.01.0FalseNoneNoneFalseNoneFalse29568.00
3845145146735Nonecode256INTERNAL WIRING -Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory-19/20mm Dia 2mm Thickm61.061.01496.0FalseNoneNoneFalseNoneFalse91256.00
3845146146735Nonecode257Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory-19/20mm Dia 2mm Thick-25mm dia 2mm Thickm70.070.02059.0FalseNoneNoneFalseNoneFalse144130.00
3845147146735Nonecode258Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory-19/20mm Dia 2mm Thick-32mm dia 2.5mm thickm93.093.050.0FalseNoneNoneFalseNoneFalse4650.00
3845148146735Nonecode259Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory-19/20mm Dia 2mm Thickm75.075.01100.0FalseNoneNoneFalseNoneFalse82500.00
3845149146735Nonecode260Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory-25mm dia 2mm Thickm80.080.01100.0FalseNoneNoneFalseNoneFalse88000.00
3845150146735Nonecode261Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory-32mm dia 2.5mm thickm105.0105.060.0FalseNoneNoneFalseNoneFalse6300.00
3845151146735Nonecode262Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes-19/20 mm Deep Junction BoxEach49.049.0239.0FalseNoneNoneFalseNoneFalse11711.00
3845152146735Nonecode263Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes-25 mm Deep Junction BoxEach51.051.087.0FalseNoneNoneFalseNoneFalse4437.00
3845153146735Nonecode264Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes-32 mm deep Junction BoxEach69.069.030.0FalseNoneNoneFalseNoneFalse2070.00
3845154146735Nonecode265Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc-20 mmm27.027.0150.0FalseNoneNoneFalseNoneFalse4050.00
3845155146735Nonecode266Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc-25 mmm28.028.0150.0FalseNoneNoneFalseNoneFalse4200.00
3845156146735Nonecode267Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc-32 mmm41.041.050.0FalseNoneNoneFalseNoneFalse2050.00
3845157146735Nonecode268Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly-20 mmm25.025.0200.0FalseNoneNoneFalseNoneFalse5000.00
3845158146735Nonecode269Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly-25 mmm31.031.0200.0FalseNoneNoneFalseNoneFalse6200.00
3845159146735Nonecode270Supply & Fixing of Metal fan box with round HookEach163.0163.045.0FalseNoneNoneFalseNoneFalse7335.00
3845160146735Nonecode271Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Make : KEI / Polycab/ Finolex-Short point upto 3 Mtd. From Tapping point to outlet via switch box.Point251.0251.0115.0FalseNoneNoneFalseNoneFalse28865.00
3845161146735Nonecode272Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Make : KEI / Polycab/ Finolex-Medium point above 3 Mts upto 6 Mts. From tapping point to outlet via switch box.Point361.0361.0110.0FalseNoneNoneFalseNoneFalse39710.00
3845162146735Nonecode273Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Make : KEI / Polycab/ Finolex-Long point above 6 Mts. Upto 10 Mts. From tapping of point to outlet via switch box.Point542.0542.085.0FalseNoneNoneFalseNoneFalse46070.00
3845163146735Nonecode274Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Make : KEI / Polycab/ Finolex-Two outlet in a row above 3 Mts upto 6 Mts, from tapping point to outlet via switch box.Point671.0671.025.0FalseNoneNoneFalseNoneFalse16775.00
3845164146735Nonecode275Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Make : KEI / Polycab/ Finolex-Three outlet in a row, above 6 Mts. Upto 10 Mts. From tapping point to outlet via switch box.Point979.0979.032.0FalseNoneNoneFalseNoneFalse31328.00
3845165146735Nonecode276Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-1.5 Sqmmm26.026.02659.0FalseNoneNoneFalseNoneFalse69134.00
3845166146735Nonecode277Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-2.5Sqmmm40.040.03695.0FalseNoneNoneFalseNoneFalse147800.00
3845167146735Nonecode278Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-4Sqmmm59.059.02600.0FalseNoneNoneFalseNoneFalse153400.00
3845168146735Nonecode279Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-10Sqmmm157.0157.0300.0FalseNoneNoneFalseNoneFalse47100.00
3845169146735Nonecode280Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-16Sqmmm318.0318.0200.0FalseNoneNoneFalseNoneFalse63600.00
3845170146735Nonecode281Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-1-3 wayEach123.0123.035.0FalseNoneNoneFalseNoneFalse4305.00
3845171146735Nonecode282Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-4-5 wayEach138.0138.030.0FalseNoneNoneFalseNoneFalse4140.00
3845172146735Nonecode283Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-6 wayEach212.0212.018.0FalseNoneNoneFalseNoneFalse3816.00
3845173146735Nonecode284Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-8 wayEach250.0250.013.0FalseNoneNoneFalseNoneFalse3250.00
3845174146735Nonecode285Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-12 wayEach325.0325.08.0FalseNoneNoneFalseNoneFalse2600.00
3845175146735Nonecode286Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-16 wayEach354.0354.06.0FalseNoneNoneFalseNoneFalse2124.00
3845176146735Nonecode287Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box1-3 wayEach152.0152.035.0FalseNoneNoneFalseNoneFalse5320.00
3845177146735Nonecode288Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-4-5 wayEach175.0175.030.0FalseNoneNoneFalseNoneFalse5250.00
3845178146735Nonecode289Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-6 wayEach244.0244.018.0FalseNoneNoneFalseNoneFalse4392.00
3845179146735Nonecode290Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-8 wayEach302.0302.013.0FalseNoneNoneFalseNoneFalse3926.00
3845180146735Nonecode291Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-10-12 wayEach363.0363.012.0FalseNoneNoneFalseNoneFalse4356.00
3845181146735Nonecode292Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-16 wayEach403.0403.010.0FalseNoneNoneFalseNoneFalse4030.00
3845182146735Nonecode293Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6 Amp one wayEach88.088.0188.0FalseNoneNoneFalseNoneFalse16544.00
3845183146735Nonecode294Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6 Amps 2 wayEach152.0152.012.0FalseNoneNoneFalseNoneFalse1824.00
3845184146735Nonecode295Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6 Amps socketEach162.0162.065.0FalseNoneNoneFalseNoneFalse10530.00
3845185146735Nonecode296Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -Stepped Fan RegulatorEach313.0313.045.0FalseNoneNoneFalseNoneFalse14085.00
3845186146735Nonecode297Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -16 Amps 1 way switchEach249.0249.061.0FalseNoneNoneFalseNoneFalse15189.00
3845187146735Nonecode298Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6 Amps Bell PushEach159.0159.02.0FalseNoneNoneFalseNoneFalse318.00
3845188146735Nonecode299Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -32 Amps DP SwitchEach375.0375.055.0FalseNoneNoneFalseNoneFalse20625.00
3845189146735Nonecode300Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6/16 Amps universal socketEach249.0249.061.0FalseNoneNoneFalseNoneFalse15189.00
3845190146735Nonecode301Supply and fixing of -Led Light Fixture 2 feet - 9/10 W-Make : Panasonic/Phillips / CromptonEach496.0496.017.0FalseNoneNoneFalseNoneFalse8432.00
3845191146735Nonecode302Supply and fixing of -Led Light Fixture 4 feet - 20/22 WEach740.0740.061.0FalseNoneNoneFalseNoneFalse45140.00
3845192146735Nonecode303Supply of recess mounted rolling type LED square or round Light 12 wattaEach835.0835.056.0FalseNoneNoneFalseNoneFalse46760.00
3845193146735Nonecode304Supply and fixing of -LED Modular Down Light 2' x 2 ' - 36 WEach5651.05651.092.0FalseNoneNoneFalseNoneFalse519892.00
3845194146735Nonecode305Fabrication and supply of sheet steel enclosure out of 14 SWG CRCA Sheet duly powder coated the contro panel ( Size of 2000 x1500x 450 ) is of compartment alized, All the components are duly wired and connected to Aluminum bus bar.-Make : Legrand / Schneider / Anchor / L&TSq CM0.430.4370000.0FalseNoneNoneFalseNoneFalse30100.00
3845195146735Nonecode306Supplying and fixing of 100 A 4 x 30 x 10 mm Alumunium Stripsm2214.02214.06.0FalseNoneNoneFalseNoneFalse13284.00
3845196146735Nonecode307Supplying and fixing of 400 A 4 x 50 x 10 mm Alumunium Stripsm3996.03996.06.0FalseNoneNoneFalseNoneFalse23976.00
3845197146735Nonecode308Supplying and fixing-16 sqmm wirem318.0318.040.0FalseNoneNoneFalseNoneFalse12720.00
3845198146735Nonecode309Supplying and fixing of LED Panel Board indicating Lamp with required colour Suitable for 220 V AC 50 HZEach464.0464.09.0FalseNoneNoneFalseNoneFalse4176.00
3845199146735Nonecode310Supplying of Multifunction Digital MeterEach8370.08370.01.0FalseNoneNoneFalseNoneFalse8370.00
3845200146735Nonecode311Supplying and fixing-250A ATSEach102600.0102600.01.0FalseNoneNoneFalseNoneFalse102600.00
3845201146735Nonecode312Supplying and fixing of 400 A MCCBEach29092.029092.01.0FalseNoneNoneFalseNoneFalse29092.00
3845202146735Nonecode313Supplying and fixing of 200 A MCCBEach21289.021289.01.0FalseNoneNoneFalseNoneFalse21289.00
3845203146735Nonecode314Supplying and fixing-63A 4P MCBEach2399.02399.06.0FalseNoneNoneFalseNoneFalse14394.00
3845204146735Nonecode315Supplying and fixing-5 - 32 A TPNNos1777.01777.013.0FalseNoneNoneFalseNoneFalse23101.00
3845205146735Nonecode316Supplying and fixing of Earth leakage relayEach8316.08316.01.0FalseNoneNoneFalseNoneFalse8316.00
3845206146735Nonecode317Supplying and fixing of 50 x 50 x 6 mm Anglem356.0356.020.0FalseNoneNoneFalseNoneFalse7120.00
3845207146735Nonecode318Fabrication and supply of sheet steel enclosure out of 14 SWG CRCA Sheet duly powder coated the contro panel ( Size of 2000 x1500x 450 ) is of compartment alized, All the components are duly wired and connected to Aluminum bus bar.Sq CM0.430.4335000.0FalseNoneNoneFalseNoneFalse15050.00
3845208146735Nonecode319Supplying and fixing of 100 A 4 x 30 x 10 mm Alumunium Stripsm2214.02214.06.0FalseNoneNoneFalseNoneFalse13284.00
3845209146735Nonecode320Supplying and fixing of LED Panel Board indicating Lamp with required colour Suitable for 220 V AC 50 HZEach464.0464.015.0FalseNoneNoneFalseNoneFalse6960.00
3845210146735Nonecode321Supply , fixing and wiring of Automatic Poer Factor ControllerEach19440.019440.01.0FalseNoneNoneFalseNoneFalse19440.00
3845211146735Nonecode322Supplying and fixing of 40 - 63 Amps TPN MCBEach2399.02399.01.0FalseNoneNoneFalseNoneFalse2399.00
3845212146735Nonecode323Supplying and fixing of 5 - 32 A TPNNos1777.01777.06.0FalseNoneNoneFalseNoneFalse10662.00
3845213146735Nonecode324Supplying and fixing of 25 AmpsEach1187.01187.06.0FalseNoneNoneFalseNoneFalse7122.00
3845214146735Nonecode325Supplying and fixing of Heavy Duty low Voltage CapacitorsKvar432.0432.030.0FalseNoneNoneFalseNoneFalse12960.00
3845215146735Nonecode326Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-4Way SP &NNos1368.01368.01.0FalseNoneNoneFalseNoneFalse1368.00
3845216146735Nonecode327Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-8Way SP &NNos1695.01695.01.0FalseNoneNoneFalseNoneFalse1695.00
3845217146735Nonecode328Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-12Way SP &NNos2067.02067.01.0FalseNoneNoneFalseNoneFalse2067.00
3845218146735Nonecode329Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-6Way TP &NNos3735.03735.01.0FalseNoneNoneFalseNoneFalse3735.00
3845219146735Nonecode330Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-8Way TP &NNos4136.04136.02.0FalseNoneNoneFalseNoneFalse8272.00
3845220146735Nonecode331Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-12Way TP &NNos5744.05744.03.0FalseNoneNoneFalseNoneFalse17232.00
3845221146735Nonecode332Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board-16 - 25 Amps 2 poleNos2536.02536.03.0FalseNoneNoneFalseNoneFalse7608.00
3845222146735Nonecode333Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board-32 - 40 Amps 2 poleNos2652.02652.010.0FalseNoneNoneFalseNoneFalse26520.00
3845223146735Nonecode334Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board-32 - 40 Amps 4 poleNos2826.02826.02.0FalseNoneNoneFalseNoneFalse5652.00
3845224146735Nonecode335Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-5 - 32 Amp SPNos523.0523.070.0FalseNoneNoneFalseNoneFalse36610.00
3845225146735Nonecode336Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-40 - 63 Amps SPNos726.0726.04.0FalseNoneNoneFalseNoneFalse2904.00
3845226146735Nonecode337Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-5 - 32 Amp DPNos1103.01103.06.0FalseNoneNoneFalseNoneFalse6618.00
3845227146735Nonecode338Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-40 - 63 Amp DPNos1376.01376.06.0FalseNoneNoneFalseNoneFalse8256.00
3845228146735Nonecode339Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-5 - 32 A TPNNos1777.01777.02.0FalseNoneNoneFalseNoneFalse3554.00
3845229146735Nonecode340Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-40 - 63 Amp TPNNos2399.02399.06.0FalseNoneNoneFalseNoneFalse14394.00
3845230146735Nonecode341Supplying Fixing and Wiring earth electrode for grounding of lifts,Xmer, DG Sets etc using 40mm dia 2.9mm thick, 2.5mtr long GI pipe with GI funnel with mesh & suitable size reducer fixed on the top of Electrode. The funnel should be enclosed in a cc chamber of 400x400x400 with a cast iron cover. The Earth electrode shall have staggered holes of 12mm dia & electrode shoulde be covered 150mm around with alternate layers of salt & charcoal from the bottom of the CC Chamber. The connection from the electrode is to be established throgh GI strip using GI bolts & nuts.Nos4150.04150.08.0FalseNoneNoneFalseNoneFalse33200.00
3845231146735Nonecode342Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required….. 25 x 3 mm G.I strip.GI Stripm75.075.0100.0FalseNoneNoneFalseNoneFalse7500.00
3845232146735Nonecode343Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required….. 600x600x3 GI Plate.GI StripEach760.0760.02.0FalseNoneNoneFalseNoneFalse1520.00
3845233146735Nonecode344Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required…..-25 x 3 mm -Cu. Stripm505.0505.050.0FalseNoneNoneFalseNoneFalse25250.00
3845234146735Nonecode345Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required…..-600x600x3 Cu. Plate-Cu. StripEach6900.06900.02.0FalseNoneNoneFalseNoneFalse13800.00
3845235146735Nonecode346Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required…-12 SWG GI wire-GI wirem14.014.0200.0FalseNoneNoneFalseNoneFalse2800.00
3845236146735Nonecode347Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-12 SWGm58.058.050.0FalseNoneNoneFalseNoneFalse2900.00
3845237146735Nonecode348Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required10 SWGm68.068.050.0FalseNoneNoneFalseNoneFalse3400.00
3845238146735Nonecode349Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-8 SWGm105.0105.050.0FalseNoneNoneFalseNoneFalse5250.00
3845239146735Nonecode350Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-2C x 10sq.mm. Al. Alum. Cablem95.095.0200.0FalseNoneNoneFalseNoneFalse19000.00
3845240146735Nonecode351Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-4C x 10sq.mm. Al. Alum. Cablem130.0130.0150.0FalseNoneNoneFalseNoneFalse19500.00
3845241146735Nonecode352Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-4C x 16sq.mm. Al. Alum. Cablem150.0150.0100.0FalseNoneNoneFalseNoneFalse15000.00
3845242146735Nonecode353Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-3.5C x 120sq.mm. Al. Alum. Cablem600.0600.050.0FalseNoneNoneFalseNoneFalse30000.00
3845243146735Nonecode354Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-3.5C x 240sq.mm. Al. Alum. Cablem1130.01130.0100.0FalseNoneNoneFalseNoneFalse113000.00
3845244146735Nonecode355Supply & Fixing of Heavy Duty Cable Glands Suitable For UG Cable of 1.1KV Class (metal Only)-25mm DiaNos84.084.030.0FalseNoneNoneFalseNoneFalse2520.00
3845245146735Nonecode356Supply & Fixing of Heavy Duty Cable Glands Suitable For UG Cable of 1.1KV Class (metal Only)-63mm DiaNos388.0388.08.0FalseNoneNoneFalseNoneFalse3104.00
3845246146735Nonecode357Supplying Tinned Cu. Lugs & crimping & wiring to terminal Point for Wire of following sizes -16sq.mm. long BarrelNos12.4412.4418.0FalseNoneNoneFalseNoneFalse223.920
3845247146735Nonecode358Supplying Tinned Cu. Lugs & crimping & wiring to terminal Point for Wire of following sizes -240Sqmm Long BarrelNos463.0463.06.0FalseNoneNoneFalseNoneFalse2778.00
3845248146735Nonecode359Supplying Tinned Cu. Lugs & crimping & wiring to terminal Point for Wire of following sizes -120 Sqmm Long BarrelNos190.0190.050.0FalseNoneNoneFalseNoneFalse9500.00
3845249146735Nonecode360Supply & Fixing 2mm thick perforated cable tray with powder coated paint on exising MS Angle support using necessary GI bolts , nuts & washer or welding as required:-150 mmX 50 MM wide tray ( Perforated type )m425.0425.020.0FalseNoneNoneFalseNoneFalse8500.00
3845250146735Nonecode361Supply & Fixing 2mm thick perforated cable tray with powder coated paint on exising MS Angle support using necessary GI bolts , nuts & washer or welding as required:-300 mm x 50 mm wide cabel tray ( Perforated type )m530.0530.020.0FalseNoneNoneFalseNoneFalse10600.00
3845251146735Nonecode362Supplying exhaust fan 0f 1440 RPM of300 mm (12") size with bracket blades complte for light duty suitable to operate on 230V 50 Hz AC Supply-Make Fans : Crompton / Usha / AnchorEach1542.01542.015.0FalseNoneNoneFalseNoneFalse23130.00
3845252146735Nonecode363Supplying capacitor type ceiling Fan complete with down rod blades shackle ,canopies etc. for operation on 230 Vots 50 cycles ,single phase AC supply confirming to ISS -374-1979 with double ball bearing system-48 " Sweep Economy modelEach2085.02085.035.0FalseNoneNoneFalseNoneFalse72975.00
3845253146735Nonecode364Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit-4.0 TR Cassette 3 PhNos141255.0141255.010.0FalseNoneNoneFalseNoneFalse1412550.00
3845254146735Nonecode365Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette typeEach4981.04981.010.0FalseNoneNoneFalseNoneFalse49810.00
3845255146735Nonecode366Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3core 80 stand copper wiring between indoor and outdoorunit Leak testing oil and gas charging for additional piping-Cassettem1763.01763.0250.0FalseNoneNoneFalseNoneFalse440750.00
3845256146735Nonecode367Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3core 80 stand copper wiring between indoor and outdoorunit Leak testing oil and gas charging for additional piping4C x 4 sqmm Copper flexible cablem158.0158.0300.0FalseNoneNoneFalseNoneFalse47400.00
3845257146735Nonecode368Supplying and installation of -5KVA offline UPSNos38661.038661.01.0FalseNoneNoneFalseNoneFalse38661.00
3845258146735Nonecode369Supplying and installation of -12V , 200 AH Capacity Acid BatteryNos15783.015783.02.0FalseNoneNoneFalseNoneFalse31566.00
3845259146735Nonecode370Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. andfixing using invetred wood plugs in Case of RCC ceiling and RCC wall /stone structure or rawl plug incase of brick walls and cement plastering the damaged portion using heavy guage saddles in an intervel of 700 mm using NF Screws-\19/20mm Dia 2mm Thickm68.068.0200.0FalseNoneNoneFalseNoneFalse13600.00
3845260146735Nonecode371Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. andfixing using invetred wood plugs in Case of RCC ceiling and RCC wall /stone structure or rawl plug incase of brick walls and cement plastering the damaged portion using heavy guage saddles in an intervel of 700 mm using NF Screws-25mm dia 2mm Thickm80.080.0100.0FalseNoneNoneFalseNoneFalse8000.00
3845261146735Nonecode372Supplying and drawing pvc insulated gas injected physical foam jelly filled co axial TV Cable Rg6m42.042.0200.0FalseNoneNoneFalseNoneFalse8400.00
3845262146735Nonecode373Supply & Fixing of 4 Pair Telephone wirem33.033.0200.0FalseNoneNoneFalseNoneFalse6600.00
3845263146735Nonecode374Supplying & drawing UTP Cat 6 E Lan Cablem34.034.0400.0FalseNoneNoneFalseNoneFalse13600.00
3845264146735Nonecode375Supply & Fixing of Single I/0Each405.0405.010.0FalseNoneNoneFalseNoneFalse4050.00
3845265146735Nonecode376Supply & Fixing of Double I/OEach727.0727.015.0FalseNoneNoneFalseNoneFalse10905.00
3845266146735Nonecode377Supply & Fixing of T.V telephone SocketEach147.0147.020.0FalseNoneNoneFalseNoneFalse2940.00
3845267146735Nonecode378Supply & Fixing of 12U with 800 mm depthEach9271.09271.01.0FalseNoneNoneFalseNoneFalse9271.00
3845268146735Nonecode379Supplying & Fixing of power StripEach1233.01233.01.0FalseNoneNoneFalseNoneFalse1233.00
3845269146735Nonecode380Supply & Fixing of 24 port 10 / 100 /1000 SwitchEach8241.08241.01.0FalseNoneNoneFalseNoneFalse8241.00
3845270146735Nonecode381Supply & Fixing of 1 Mtr patch cableEach190.0190.015.0FalseNoneNoneFalseNoneFalse2850.00
3845271146735Nonecode382Supply & Fixing of 2 Mtr patch cableEach286.0286.015.0FalseNoneNoneFalseNoneFalse4290.00
3845272146735Nonecode383Supply & Fixing of 24 port 10 / 100 patch panelEach4258.04258.01.0FalseNoneNoneFalseNoneFalse4258.00
3845273146735Nonecode384Fabricating, supplying and erection of ...Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom …..mm, top….mm with 3/4mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the pole shall be galvanized with not less than 65micron etc as per ASTM-A 123 and 153 etc., (excluding foundation) as per drawing appended. a)3 Meters-Top 70mm and bottom 130mm diaEach5671.05671.04.0FalseNoneNoneFalseNoneFalse22684.00
3845274146735Nonecode385Fabricating, supplying and erection of ...Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom …..mm, top….mm with 3/4mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the pole shall be galvanized with not less than 65micron etc as per ASTM-A 123 and 153 etc., (excluding foundation) as per drawing appended. b)5 Meters-Top 70mm and bottom 130mm diaEach8871.08871.04.0FalseNoneNoneFalseNoneFalse35484.00
3845275146735Nonecode386Supplying and fixing Led Street Light70 wattsEach5955.05955.08.0FalseNoneNoneFalseNoneFalse47640.00
3845276146735Nonecode387Supplying and fixing 4C x 16sq.mm. Al. Alum. Cablem150.0150.0150.0FalseNoneNoneFalseNoneFalse22500.00
3845277146735Nonecode388Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., completem102.0102.0120.0FalseNoneNoneFalseNoneFalse12240.00
3845278146735Nonecode389Labour charges for laying of 1.1 KV class UG cable when supplied agency in existing trench GI pipe / stoneware pipe / on wall / on pole as required.(69/5) - In exixting trench/duct. 6sqmm to 16 sqmmm11.811.8150.0FalseNoneNoneFalseNoneFalse1770.00
3845279146735Nonecode390Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable (Sl no 7.10 page no 62)m100.0100.0150.0FalseNoneNoneFalseNoneFalse15000.00
3845280146735Nonecode391Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 SqmmEach12.4412.4426.0FalseNoneNoneFalseNoneFalse323.440
3845281146735Nonecode392Supplying and fixing 25mm DiaNos80.080.0100.0FalseNoneNoneFalseNoneFalse8000.00
3845282146735Nonecode393Supplying and fixing 70 Watt Led Flood lightNos7390.07390.04.0FalseNoneNoneFalseNoneFalse29560.00
3845283146735Nonecode394Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130- 1984 and (Virgin) PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A-4C x 2.5 sqmmm141.0141.0200.0FalseNoneNoneFalseNoneFalse28200.00
3845284146735Nonecode395Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -6Way TP &NNos3735.03735.01.0FalseNoneNoneFalseNoneFalse3735.00
3845285146735Nonecode396Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board-16 - 25 Amps 2 poleNos2536.02536.03.0FalseNoneNoneFalseNoneFalse7608.00
3845286146735Nonecode397Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-5 - 32 Amp SPNos523.0523.04.0FalseNoneNoneFalseNoneFalse2092.00
3845287146735Nonecode398Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-40 - 63 Amps SPNos726.0726.04.0FalseNoneNoneFalseNoneFalse2904.00
3845288146735Nonecode399Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-8W 0.5 Mtr Height Bollard LightNos3391.03391.08.0FalseNoneNoneFalseNoneFalse27128.00
3845289146735Nonecode400Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-LED Post Top Lantern with 25 WattNos7173.07173.05.0FalseNoneNoneFalseNoneFalse35865.00
3845290146735Nonecode401Supply, installation, testing and commisioning of Flush mount model chairman unit with gooseneck mic with ring LED and intreconnection cable and out socket for linking next units with talk and priority switch with delegate inter face unit aliminum/ PVC HousingNos34800.034800.01.0FalseNoneNoneFalseNoneFalse34800.00
3845291146735Nonecode402Supply, installation, testing and commisioning of Flush mount model delegate unit with gooseneck mic with ring LED and intreconnection cable and out socket for linking next units with talk and priority switch with delegate inter face unit aliminum/ PVC HousingNos32800.032800.01.0FalseNoneNoneFalseNoneFalse32800.00
3845292146735Nonecode403Supply, installation, testing and commisioning of Table top model chairman unit with gooseneck mic with ring LED and intreconnection cable and out socket for linking next units with talk and priority switch with delegate inter face unit aliminum/ PVC Housing and Headphone socketNos12400.012400.01.0FalseNoneNoneFalseNoneFalse12400.00
3845293146735Nonecode404Supply, installation, testing and commisioning of Table top model delegate unit with gooseneck mic with ring LED and intreconnection cable and out socket for linking next units with talk and priority switch with delegate inter face unit aliminum/ PVC Housing and Headphone socketNos12400.012400.01.0FalseNoneNoneFalseNoneFalse12400.00
3845294146735Nonecode405Supply, installation, testing and commisioning of controller unit with 1 mic input 1aux PA out, rack mountable can handle up to 50 to 300 delegate units with expansion optionsNos174000.0174000.01.0FalseNoneNoneFalseNoneFalse174000.00
3845295146735Nonecode406Supply, installation, testing and commisioning of controller unit with 1 mic input 1aux PA out, rack mountable can handle up to 60 delegate units with expansion optionsNos103.0103.055.0FalseNoneNoneFalseNoneFalse5665.00
3845296146735Nonecode407Supply, installation, testing and commisioning of 9 core multistrand high gain low cable with required end connectors 10 meter to connect between the delegate units and controller including charges for labour, lead and lifts, loading and unloadingNos220.0220.05.0FalseNoneNoneFalseNoneFalse1100.00
3845297146735Nonecode408Supply, installation, testing and commisioning of compact ceiling speaker with Back Can Power handling up to 6 watt RMS/watt/100volt @ 1456 ohms single channel selectable taping 5'' LF driver and tweeterNos1450.01450.010.0FalseNoneNoneFalseNoneFalse14500.00
3845298146735Nonecode409Supplying, installing and commissioning of CCTV Surveillance System.-CCTV Surveillance Cameras-Indoor Dome IR Camera, HD VideoNos6900.06900.012.0FalseNoneNoneFalseNoneFalse82800.00
3845299146735Nonecode410Outdoor Bullet- 25 Mtrs Range, HD VideoNos7500.07500.02.0FalseNoneNoneFalseNoneFalse15000.00
3845300146735Nonecode411Power Supply 12VDC, Each Supports upto 5 IR CamerasNos3300.03300.05.0FalseNoneNoneFalseNoneFalse16500.00
3845301146735Nonecode41216 Channel DVR, HD, with 2TB Surveillance HDDNos57000.057000.01.0FalseNoneNoneFalseNoneFalse57000.00
3845302146735Nonecode41319 Color Monitor For DVRNos10440.010440.01.0FalseNoneNoneFalseNoneFalse10440.00
3845303146735Nonecode414CCTV Cabling including PVC Conduitm114.0114.0700.0FalseNoneNoneFalseNoneFalse79800.00
3845304146735Nonecode415Supplying , Errection , Testing and Commissioning of Diesel Generator Set on existing CC platform comprising of Diesel Engine developing -----BHP @1500 RPM confirming to BS 5514-62.5 KVA /50 KWNos618585.0618585.01.0FalseNoneNoneFalseNoneFalse618585.00
3845305146735Nonecode416Supply , Erection , Testing and commissioning of AMF Panel suitable for DG Set-up to 62.5 KVANos75900.075900.01.0FalseNoneNoneFalseNoneFalse75900.00
3845306146735Nonecode417SUMP TANK-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m-Cum114.24114.2447.8FalseNoneNoneFalseNoneFalse5460.6720
3845307146735Nonecode418Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-Cum6992.166992.163.88FalseNoneNoneFalseNoneFalse27129.58080
3845308146735Nonecode419Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-Cum297.92297.922.3FalseNoneNoneFalseNoneFalse685.2160
3845309146735Nonecode420Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- FOOTINGCum8277.298277.293.39FalseNoneNoneFalseNoneFalse28060.01310
3845310146735Nonecode421Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- RCC WALLCum13029.0713029.076.59FalseNoneNoneFalseNoneFalse85861.57130
3845311146735Nonecode422Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- SLABCum11496.2411496.242.75FalseNoneNoneFalseNoneFalse31614.660
3845312146735Nonecode423Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.Sqm371.84371.8480.2FalseNoneNoneFalseNoneFalse29821.5680
3845313146735Nonecode424KSRB 12-6.2: Providing 20mm round M.S. footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos286.72286.7210.0FalseNoneNoneFalseNoneFalse2867.20
3845314146735Nonecode425Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SL.NO-11.32, PG.NO-84, VOLUME-II.Tonne88492.3288492.321.27FalseNoneNoneFalseNoneFalse112385.24640
3845315146735Nonecode426SEPTIK TANK-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m-Cum114.24114.2447.8FalseNoneNoneFalseNoneFalse5460.6720
3845316146735Nonecode427Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates. sl.no-2.1.2, pg.no-15. volume-1Cum6992.166992.163.88FalseNoneNoneFalseNoneFalse27129.58080
3845317146735Nonecode428Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-Cum297.92297.922.3FalseNoneNoneFalseNoneFalse685.2160
3845318146735Nonecode429Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- FOOTINGCum8277.298277.293.39FalseNoneNoneFalseNoneFalse28060.01310
3845319146735Nonecode430Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- RCC WALLCum13029.0713029.079.0FalseNoneNoneFalseNoneFalse117261.630
3845320146735Nonecode431Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- SLABCum11496.2411496.242.75FalseNoneNoneFalseNoneFalse31614.660
3845321146735Nonecode432Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.Sqm371.84371.8483.3FalseNoneNoneFalseNoneFalse30974.2720
3845322146735Nonecode433KSRB 12-6.2: Providing 20mm round M.S. footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos286.72286.7210.0FalseNoneNoneFalseNoneFalse2867.20
3845323146735Nonecode434Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SL.NO-11.32, PG.NO-84, VOLUME-II.Tonne88492.3288492.321.51FalseNoneNoneFalseNoneFalse133623.40320
3845324146735Nonecode435BOREWELL-Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1)       Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a)     Above 20 M and upto 30 M - 15%, b)     Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2)   A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test etc. completeNos5922.565922.562.0FalseNoneNoneFalseNoneFalse11845.120
3845325146735Nonecode436Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 0 to 50 Mtrsm414.4414.450.0FalseNoneNoneFalseNoneFalse20720.00
3845326146735Nonecode437Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 50 to 100 Mtrsm519.68519.6850.0FalseNoneNoneFalseNoneFalse25984.00
3845327146735Nonecode438Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)Borewell depth of 100 to 150 Mtrsm552.16552.1650.0FalseNoneNoneFalseNoneFalse27608.00
3845328146735Nonecode439Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 150 to 200 Mtrsm640.64640.6425.0FalseNoneNoneFalseNoneFalse16016.00
3845329146735Nonecode440Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)--Borewell depth of 200 to 250 Mtrsm751.52751.5260.0FalseNoneNoneFalseNoneFalse45091.20
3845330146735Nonecode441Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete-5.00 HP/3.7KW-50 STGNos33208.033208.01.0FalseNoneNoneFalseNoneFalse33208.00
3845331146735Nonecode442Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments-1x3x6 Sqm.m207.2207.2168.0FalseNoneNoneFalseNoneFalse34809.60
3845332146735Nonecode443Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments-Size 65 mmNos1736.01736.04.0FalseNoneNoneFalseNoneFalse6944.00
3845333146735Nonecode444Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.-3 to 6 HP pumpsEach11760.011760.01.0FalseNoneNoneFalseNoneFalse11760.00
3845334146735Nonecode445Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsm616.0616.0125.0FalseNoneNoneFalseNoneFalse77000.00
3845335146735Nonecode446Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets.Kvar616.0616.01.0FalseNoneNoneFalseNoneFalse616.00
3845336146735Nonecode447Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI markNos5040.05040.01.0FalseNoneNoneFalseNoneFalse5040.00
3845337146735Nonecode448Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.Job1512.01512.01.0FalseNoneNoneFalseNoneFalse1512.00
3845338146735Nonecode449Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work- 3.5 x 10 sqmmm218.4218.4168.0FalseNoneNoneFalseNoneFalse36691.20
3845339146735Nonecode450Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Job4200.04200.01.0FalseNoneNoneFalseNoneFalse4200.00
3845340146735Nonecode451Providing and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work.-3.5x10 SqmEach504.0504.01.0FalseNoneNoneFalseNoneFalse504.00
3845341146735Nonecode452Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments.-5 HP, size 50x40 Head 46M, Discharge 174 LPMEach29587.0429587.041.0FalseNoneNoneFalseNoneFalse29587.040
3845342146735Nonecode453NON SR RATES-Providing and fixing Aluminium fixtures like aldrops of size 300x16mm,tower bolts of size 200 x 12mm, latches of size 250x12mm, 100mm length oxidized iron hinges,handles of size 150mm, door stoper and door brush of approved make and quality including cost oof conveyance of all meterials and as per the direction of EIC of work with all lead and lift and as directed by the engineer in charge of works.Single shutterNos4434.04434.03.0FalseNoneNoneFalseNoneFalse13302.00
3845343146735Nonecode454Providing and fixing sash mortise lock body with cylinder outside key and inside knob suitable for flush doors including cost of materials labours etc,. Complete as per specificationsNos2150.02150.03.0FalseNoneNoneFalseNoneFalse6450.00
3845344146735Nonecode455Providing supplying and fixing ss satin finish barrel bolt/aldrop-300mm for door shutters including cost of materials,labour etc., complete as per specifications.,Nos575.0575.06.0FalseNoneNoneFalseNoneFalse3450.00
3845345146735Nonecode456Providing supplying and fixing floor mounted door stopper suitable for flush door shutters including cost of materials,labour etc., complete as per specifications.,Nos550.0550.06.0FalseNoneNoneFalseNoneFalse3300.00
3845346146735Nonecode457Providing supplying and fixing ss door handle set (22mm dia 300mm long ) including cost of materials,labour etc., complete as per specifications.,Nos1550.01550.06.0FalseNoneNoneFalseNoneFalse9300.00
3845347146735Nonecode458Providing supplying and fixing Hydraulic door closures with mounting heavy duty shuitable for flush door shutters including cost of materials,labour etc., complete as per specifications.,Nos1350.01350.020.0FalseNoneNoneFalseNoneFalse27000.00
3845348146735Nonecode459Providing supplying and fixing SS but hinges for fixing door shutter to frame for flush door shutters including cost of materials,labour etc., complete as per specifications.,Nos375.0375.030.0FalseNoneNoneFalseNoneFalse11250.00
3845349146735Nonecode460Providing supplying and fixing SS screws-25mm for fixing door shutter to frame for flush door shutters including cost of materials,labour etc., complete as per specifications.,Nos4.04.0180.0FalseNoneNoneFalseNoneFalse720.00
3845350146735Nonecode461Providing supplying and fixing MS Holdfast of size 260mm x 25mm x 5mm thk for fixing door frames to walls, including cost of materials cutting masonry pockets for receiving ms holdfasts one coat of shop primer,concrete filling of pockets,desposal of debries, including cost of materials,labour etc., complete as per specifications.,Nos45.045.024.0FalseNoneNoneFalseNoneFalse1080.00
3845351146735Nonecode462Supplying, installing, testing and commissioning approved make15 mm CP health faucet of approved make with necessary CP flexible hose 1.0m long nozzle, CP crutch,nozzle anguler stop cock with wall flange etc., complete.make: Jaguar,modle no. ALD-573Nos1307.01307.015.0FalseNoneNoneFalseNoneFalse19605.00
3845352146735Nonecode463Supplying, installing and testing Soap Dish including necessary fixing materials etc., complete. (Jal,Jaquar or equivalent)Nos126.0126.025.0FalseNoneNoneFalseNoneFalse3150.00
3845353146735Nonecode464Forming horizontal or vertical grooves on uniform size 10 mm wide and 7 mm deep at junction of wall and column / beam and finishing the grooves to elevation etc, including cost of materials , labour flor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incindental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.per the instructions of the Engineer in charge. (All floors)-Front side Elevationm31.031.01300.0FalseNoneNoneFalseNoneFalse40300.00
3845354146735Nonecode465Forming horizontal or vertical grooves on uniform size 10 mm wide and 7 mm deep at junction of wall and column / beam and finishing the grooves to elevation etc, including cost of materials , labour flor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incindental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.per the instructions of the Engineer in charge. (All floors)-Front side Elevationm31.031.0300.0FalseNoneNoneFalseNoneFalse9300.00
3845355146735Nonecode466Forming horizontal or vertical grooves on uniform size 10 mm wide and 7 mm deep at junction of wall and column / beam and finishing the grooves to elevation etc, including cost of materials , labour flor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incindental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.per the instructions of the Engineer in charge. (All floors)-top parapet wallm31.031.0600.0FalseNoneNoneFalseNoneFalse18600.00
3845356146735Nonecode467MOULDING : Providing 200 mm height architectural moulding with three stepswith 50mm on top and bottom and 100 mm middle champhered steps in standard architectural methods of execution running on thre edge of the slab, canopy and other places as shown in the drawings or as per the instructions given. the rate includes, materials, labour and complete.-elevation slopem1800.01800.0300.0FalseNoneNoneFalseNoneFalse540000.00
3845357146735Nonecode468Supplying fixing,testing, and commisioning of solar water heating system suitable/designed for "forced circulation" with solar panels hot water storage tank with supporting brackets etc complete. The solar water heater shall consists of the following Capacity : 200 LPD SS body solar panel with copper collectors SS body Bottom insulation of solar panel with 100 microns laminated with rock wool of 48kg/cum density Support structure made out of polyster powder coated CR tubes 1 No. Air release/vaccum release safty valve with a ball valve of 20mm dia. Uniform out put on continous usage. intel and outlet provision. Necessary interconnecting piping between panel to staorage tank etc.Nos78000.078000.01.0FalseNoneNoneFalseNoneFalse78000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17244004130000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17244004130000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17244004130000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17244004130000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17244004130000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17244004150000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17244004180000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17244004230000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17244004260000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17244004320000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17244004350000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17244004370000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17244004400000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17244004430000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17244004460000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17244004490000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17244004520000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17244004550000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17244004590000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17244004630000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1724412019000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone