createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1724643415489
version6
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1250.00
emd100000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose02-09-2024 15:00:00
tenderQueryClose02-09-2024 12:00:00
technicalBidOpen03-09-2024 15:00:01
publishedDate26-08-2024 09:24:24
publishedByPostCMC_MCOM_RBPT
publishedByUserKPE15282 - PAVANKUMAR K M
bidValidityPeriod90
noOfCalls2
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonManjunatha AEE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08151256260
mobileNumber8147635005
tenderSupplierListNone
tenderSchedule
createdTs1724643415492
version10
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT21258/CALL-2
titleConstruction of Balance civil works and providing necessary pump and motor pipe line and other relavant accsessories to GLSR Sump Tank constructed under Nagarothana-3 Scheme in ward no 01 o 18 in CMC KGF Limits.
descriptionWater Supply Works
categoryWORKS
categoryTextWorks
ecv5000000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2344
locationNameDMA City Municipal Council Robertsonpete KGF
provisionalAmount5000000.0
groupOverheadTotal762897.58
fileNumberCMC/KGF/AEE/TND/03/2024-25/14
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17246434160000NoneNoneOther WorksConstruction of Balance civil works and providing necessary pump and motor pipe line and other relavant accsessories to GLSR Sump Tank constructed under Nagarothana-3 Scheme in ward no 01 o 18 in CMC KGF Limits.4237102.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3853252147301Nonecode01Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications [PWD SR 2023-24 Vol:2 P.NO.17 I.No:6.32]Sqm1349.31349.3172.26FalseNoneNoneFalseNoneFalse232430.4180
3853253147301Nonecode02Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [PWD SR 2023-24 Vol:1 P.NO.16 I.No:2.3.1]Cum10926.2410926.242.592FalseNoneNoneFalseNoneFalse28320.814080
3853254147301Nonecode03Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [PWD SR 2023-24 Vol:1 P.NO.16 I.No:2.3.1]Cum10243.3510243.358.1FalseNoneNoneFalseNoneFalse82971.1350
3853255147301Nonecode04Supplying Heavy gauge PVC Conduit pipe 20mm dia 2mm thick confirming to IS 2509 with suitable size bends metal/PVC Junction Boxes adhesive paste etc., and running before concreting the slab The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures run with 18 SWG GI Fish Wire Wherever necessary. [PWD SR 2023-24 Vol:6 P.NO.2 I.No:1.2.1]m67.9867.98120.0FalseNoneNoneFalseNoneFalse8157.60
3853256147301Nonecode05Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures. [PWD SR 2023-24 Vol:1 P.NO.18 I.No: 2.11(h)]Tonne81381.3381381.3311.691FalseNoneNoneFalseNoneFalse951429.129030
3853257147301Nonecode06Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.[PWD SR 2023-24 Vol:2 P.NO.41 I.No:8.3.1]Sqm364.62364.622067.12FalseNoneNoneFalseNoneFalse753713.29440
3853258147301Nonecode07Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life).[PWD SR 2023-24 Vol:2 P.NO.46 I.No:8.33.1]Sqm162.74162.742067.12FalseNoneNoneFalseNoneFalse336403.10880
3853259147301Nonecode08Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). [PWD SR 2023-24 Vol:2 P.NO.112 I.No:12.95]Sqm4543.334543.3311.34FalseNoneNoneFalseNoneFalse51521.36220
3853260147301Nonecode09Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer- in-charge: Profile E Fixing with adjustable lugs with split end tail to each jamb including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.[PWD SR 2023-24 Vol:2 P.NO.81 I.No:11.14.3.1]m546.93546.9336.0FalseNoneNoneFalseNoneFalse19689.480
3853261147301Nonecode10Providing & fixing of 2 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC m2 5,023.00 Sl. No. Specification Unit Rate Page 109 Karnataka Public Works Department Volume-2 KPWD VOL 2 honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm. Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made).[PWD SR 2023-24 Vol:2 P.NO.108 I.No:12.84]Sqm5173.695173.6910.799FalseNoneNoneFalseNoneFalse55870.678310
3853262147301Nonecode11Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: DOL- Direct Online Starter S-D- Star Delta Starter etc. complete. 6 to 15 HP pumps. [PWD SR 2023-24 Vol:5 P.NO.155 I.No:13.24.3]Each18025.018025.02.0FalseNoneNoneFalseNoneFalse36050.00
3853263147301Nonecode12Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 7.5 HP, size 65x50 Head 46 M Discharge 360LPM [PWD SR 2023-24 Vol:5 P.NO.157 I.No:13.40.8]Each36204.536204.56.0FalseNoneNoneFalseNoneFalse217227.00
3853264147301Nonecode13Supply and delivery at site brand new best make pressure guage suitable for centrifugal pump confirming to latest IS standards.pressure guage 80MM [PWD SR 2023-24 Vol:5 P.NO.157 I.No:13.41.1]Each614.91614.916.0FalseNoneNoneFalseNoneFalse3689.460
3853265147301Nonecode14Supply and delivery at site brand new best make level guage suitable for centrifugal pump confirming to latest IS standards. [PWD SR 2023-24 Vol:5 P.NO.157 I.No:13.42]Each772.5772.56.0FalseNoneNoneFalseNoneFalse4635.00
3853266147301Nonecode15Supply and delivery at site brand new best make starter/ control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments. 7.5 to 10 HP centrifugal pump [PWD SR 2023-24 Vol:5 P.NO.158 I.No:13.43.2]Each16016.516016.56.0FalseNoneNoneFalseNoneFalse96099.00
3853267147301Nonecode16Providing and fixing LT cable of size 4 x 25 Sqm suitable for centrifugal pump sets with ISI mark and its latest amendments [PWD SR 2023-24 Vol:5 P.NO.158 I.No:13.46]m578.86578.86180.0FalseNoneNoneFalseNoneFalse104194.80
3853268147301Nonecode17Supply and delivery at site brand new best make Foot valve suitable for centrifugal pump upto 10HP confirming with ISI mark and its latest amendments.[PWD SR 2023-24 Vol:5 P.NO.158 I.No:13.46]Each1802.51802.56.0FalseNoneNoneFalseNoneFalse10815.00
3853269147301Nonecode18Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete.Heavy Duty GI pipe of 100mm dia [PWD SR 2023-24 Vol:5 P.NO.128 I.No:11.3.9]m1454.361454.3672.0FalseNoneNoneFalseNoneFalse104713.920
3853270147301Nonecode19Supplying and Fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc., 200x200x65 [PWD SR 2023-24 Vol:6 P.NO.2 I.No:1.4.7]Each358.44358.4472.0FalseNoneNoneFalseNoneFalse25807.680
3853271147301Nonecode20Point wiring using copper wire with switch : Supplying and wiring adopting loop system in existing PVC Condit/casing capping using 2x1.5 Sqmm (phase & Neutral) & 1x1.0 sqmm (earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gand box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block cmplete for each outlet Short Point upto 3mtr from tapping point to out let via switch.[PWD SR 2023-24 Vol:6 P.NO.5 I.No:2.1.1]Point293.55293.5518.0FalseNoneNoneFalseNoneFalse5283.90
3853272147301Nonecode21Point wiring using copper wire with switch :Supplying and wiring adopting loop system in existing PVC Condit/casing capping using 2x1.5 Sqmm (phase & Neutral) & 1x1.0 sqmm (earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gand box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block cmplete for each outlet Medium Point above 3mtr upto 6mtr from tapping point to out let via switch.[PWD SR 2023-24 Vol:6 P.NO.5 I.No:2.1.2]Point405.82405.8218.0FalseNoneNoneFalseNoneFalse7304.760
3853273147301Nonecode22Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694-2010. 2.50Sqmm.[PWD SR 2023-24 Vol:6 P.NO.5 I.No:2.3.3]m43.2643.26720.0FalseNoneNoneFalseNoneFalse31147.20
3853274147301Nonecode23Supplying 6A Flush Type socket and 6A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 2 Way.[PWD SR 2023-24 Vol:6 P.NO.5 I.No:3.1.1]Each131.84131.8430.0FalseNoneNoneFalseNoneFalse3955.20
3853275147301Nonecode24Cutting road surfaces for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the classifications for: Macadam RoadCum840.48840.4873.44FalseNoneNoneFalseNoneFalse61724.85120
3853276147301Nonecode25Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. in all kinds of Soil depth Upto 1.50M [PWD SR 2023-24 Vol:1 P.NO.6 I.No:1.6.1 ]Cum498.52498.52550.8FalseNoneNoneFalseNoneFalse274584.8160
3853277147301Nonecode26Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3 [PWD SR 2023-24 Vol:5 P.NO.113 I.No:10.1.5]m226.6226.61224.0FalseNoneNoneFalseNoneFalse277358.40
3853278147301Nonecode27Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 90mm dia., 6 kg/sqcm & class 3 [PWD SR 2023-24 Vol:5 P.NO.113 I.No:10.1.6]m302.82302.821224.0FalseNoneNoneFalseNoneFalse370651.680
3853279147301Nonecode28Providing and installing at site of work P.V.C. Gate Valves including cost of labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.PVC Gate Valve 90mm dia [Least Market Rate]Each650.0650.024.0FalseNoneNoneFalseNoneFalse15600.00
3853280147301Nonecode29Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m.Including cost of all labour complete as per specifications [PWD SR 2021-22 Vol:1 P.NO.7 I.No:1.10]Cum125.66125.66523.259FalseNoneNoneFalseNoneFalse65752.725940
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17246434150000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17246434150000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17246434160000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17246434160000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17246434160000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17246434160000NoneNoneELIGIBILITYAll Conditions Shall apply as per KW DocumentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
NoneNoneNoneNoneSatisfactory completed, at least one similar type of water Supply work of value not less than Rs 25.00 (Inclusive of GST) Lakhs.as prime contractorPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of not less than Rs.15.00 Lakhs (Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etc. (usually 30% of amount of contract)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAchieved in at least two financial years an average annual financial turnover (in all classes of civil engineering construction works only) of Rs 50.00 lakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClass-III & above PWD Contractor Registration CertificateOthersPWD Contractor Registration
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneGST certificateOthersGST certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneB ValueOthersB Value
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- B Value
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Work done CertificateTrueTechnical Bid
Letter of creditTrueTechnical Bid
GST CertificateTrueTechnical Bid
b valueTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone