| 1724565995000 | 0 | None | None | Other Works | Construction of MRF Building (Material l Recovery Facility) in Survey no. 224 at Attibele TMC Limits | 2945226.76 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3852555 | 147244 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work PWD CSR 2023-24, Vol-I, P. No. 8, I. No. 1.14.1 | Cum | 105.06 | 105.06 | 128.1486 | False | None | None | False | None | False | 13463.291916 | 0 | | 3852556 | 147244 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications - Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates PWD CSR 2023-24, Vol-I, P. No. 15, I. No. 2.1.3 | Cum | 6168.67 | 6168.67 | 17.83 | False | None | None | False | None | False | 109987.3861 | 0 | | 3852557 | 147244 | None | code03 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2023-24, Vol-I, P. No. 15, I. No. 2.1.3 | Cum | 7033.71 | 7033.71 | 4.84 | False | None | None | False | None | False | 34043.1564 | 0 | | 3852558 | 147244 | None | code04 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2023-24, Vol-I, P. 16, I. 2.5.1 | Cum | 11609.13 | 11609.13 | 1.368 | False | None | None | False | None | False | 15881.28984 | 0 | | 3852559 | 147244 | None | code05 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6
(1 cement : 6 coarse sand) PWD CSR 2023-24, Vol-II, P. No. 9, I. No. 5.4 | Cum | 6580.67 | 6580.67 | 36.21 | False | None | None | False | None | False | 238286.0607 | 0 | | 3852560 | 147244 | None | code06 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift upto 1.5 m. PWD CSR 2023-24, Vol-I,P. No. 7, I. No. 1.9 | Cum | 273.98 | 273.98 | 39.528 | False | None | None | False | None | False | 10829.88144 | 0 | | 3852561 | 147244 | None | code07 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarseaggregates PWD CSR 2023-24, Vol-I, P. No. 16, I. No. 2.4.2 | Cum | 9769.03 | 9769.03 | 8.16 | False | None | None | False | None | False | 79715.2848 | 0 | | 3852562 | 147244 | None | code08 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. PWD CSR 2023-24, Vol-II, P. No. 17, I.6.32 | Sqm | 1349.3 | 1349.3 | 202.254 | False | None | None | False | None | False | 272901.3222 | 0 | | 3852563 | 147244 | None | code09 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. PWD CSR 2023-24, Vol-II, P. No. 17, | Sqm | 1137.12 | 1137.12 | 68.99 | False | None | None | False | None | False | 78449.9088 | 0 | | 3852564 | 147244 | None | code10 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications -M20DesignMix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2023-24, Vol-I, P. 16, I. 2.5.1 | Cum | 6828.9 | 6828.9 | 22.13 | False | None | None | False | None | False | 151123.557 | 0 | | 3852565 | 147244 | None | code11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/ welding joints, tying with binding wire /soft annealed steel wire and other ancilary operations complete as per drawing and technical specification - For Buildings PWD CSR 2023-24, Vol-I, P. No. 18, I. No. 2.11a | Tonne | 92140.71 | 92140.71 | 2.7415 | False | None | None | False | None | False | 252603.756465 | 0 | | 3852566 | 147244 | None | code12 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percentconcentration, labour, usage charges of machinery, complete as per specifications. PWD CSR 2023-24, Vol-II, P. No.5, I. 4.1 | Sqm | 121.54 | 121.54 | 94.6904 | False | None | None | False | None | False | 11508.671216 | 0 | | 3852567 | 147244 | None | code13 | Formwork for Beams and lintels @ 60% of the rate of concrete. PWD CSR 2023-24, Vol-I, P. No.111, addendum1 | Cum | 4097.34 | 4097.34 | 3.78 | False | None | None | False | None | False | 15487.9452 | 0 | | 3852568 | 147244 | None | code14 | Formwork for Roof slab @ 50% of the rate of concrete. PWD CSR 2023-24, Vol-I, P. No.111, addendum1 | Cum | 3414.45 | 3414.45 | 16.4 | False | None | None | False | None | False | 55996.98 | 0 | | 3852569 | 147244 | None | code15 | Formwork for Chejja @ 45% of the rate of concrete. PWD CSR 2023-24, Vol-I, P. No.111, addendum1 | Cum | 3073.0 | 3073.0 | 1.95 | False | None | None | False | None | False | 5992.35 | 0 | | 3852570 | 147244 | None | code16 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD CSR 2023-24, Vol-II, P.No. 41, I. No. 8.4.2 | Sqm | 321.36 | 321.36 | 440.98 | False | None | None | False | None | False | 141713.3328 | 0 | | 3852571 | 147244 | None | code17 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as perdirections of Engineer-in-charg PWD CSR 2023-24, Vol-II, P. No. 41, I. No. 8.3.1 | Sqm | 364.62 | 364.62 | 154.68 | False | None | None | False | None | False | 56399.4216 | 0 | | 3852572 | 147244 | None | code18 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) PWD CSR 2023-24, Vol-II, P. No. 46, I. 8.33.1 | Sqm | 162.74 | 162.74 | 595.663 | False | None | None | False | None | False | 96938.19662 | 0 | | 3852573 | 147244 | None | code19 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse
sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white PWD CSR 2023-24, Vol-II, P. No. 60, I. 9.9 | Sqm | 1108.28 | 1108.28 | 55.25 | False | None | None | False | None | False | 61232.47 | 0 | | 3852574 | 147244 | None | code20 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. allcomplete as specified and as directed by the Engineer-in-Charge. PWD CSR 2023-24, Vol-II, P.63 I. 9.24 | Sqm | 2937.56 | 2937.56 | 9.55 | False | None | None | False | None | False | 28053.698 | 0 | | 3852575 | 147244 | None | code21 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels - Area of slab over 0.50m2 PWD CSR 2023-24, Vol-II, P. No. 69, I. No. 10.1.2 | Sqm | 4055.11 | 4055.11 | 9.0 | False | None | None | False | None | False | 36495.99 | 0 | | 3852576 | 147244 | None | code22 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigmentof matching shade complete.PWD CSR 2023-24, Vol-II, P. No. 71, I. No. 10.14 | Sqm | 1139.18 | 1139.18 | 52.5 | False | None | None | False | None | False | 59806.95 | 0 | | 3852577 | 147244 | None | code23 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1 sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessaryaccessories, sealing shall be done with necessary rods etc., complete - For Straight Portion PWD CSR 2023-24, Vol-II, P. No. 71, I. No. 10.15.1 | Sqm | 4108.67 | 4108.67 | 16.5 | False | None | None | False | None | False | 67793.055 | 0 | | 3852578 | 147244 | None | code24 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost ofmaterials, labour, usage charges of machinery complete as per specifications PWD CSR 2023-24, Vol-II, P. No.85, I. No. 11.28 | Kgs | 581.95 | 581.95 | 65.8 | False | None | None | False | None | False | 38292.31 | 0 | | 3852579 | 147244 | None | code25 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 1mm), with wall thickness 2.0 mm ( 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (0.1 mm) wall thickness and 3 nos.stainless steelhinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section PWD CSR 2023-24, Vol-II, P. No. 108, I.12.83.2 | m | 246.17 | 246.17 | 80.1 | False | None | None | False | None | False | 19718.217 | 0 | | 3852580 | 147244 | None | code26 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be
made) PWD CSR 2023-24, Vol-II, P. No. 111, I. No. 12.92 | Sqm | 6432.35 | 6432.35 | 25.695 | False | None | None | False | None | False | 165279.23325 | 0 | | 3852581 | 147244 | None | code27 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minorT&P's shall not be made) PWD CSR 2023-24, Vol-II, P. No. 109, I. No. 12.85 | Sqm | 5890.57 | 5890.57 | 9.72 | False | None | None | False | None | False | 57256.3404 | 0 | | 3852582 | 147244 | None | code28 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm diasteel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery completeas per specifications and as per directions of the Engineer-in-Charge. PWD CSR 2023-24, Vol-II, P. No. 77, I. No. 11.3 | Sqm | 8524.28 | 8524.28 | 10.88 | False | None | None | False | None | False | 92744.1664 | 0 | | 3852583 | 147244 | None | code29 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required tocomplete the work as per technical specifications. PWD CSR 2023-24, Vol-II, P. No. 15, I. No. | Cum | 6430.29 | 6430.29 | 6.0 | False | None | None | False | None | False | 38581.74 | 0 | | 3852584 | 147244 | None | code30 | Water proofing materials PWD CSR 2023-24, Vol-II, P. No.A-43 I. No.1028 | Kg | 45.32 | 45.32 | 40.0 | False | None | None | False | None | False | 1812.8 | 0 | | 3852585 | 147244 | None | code31 | Providing and fixing unplasticised PVC connection pipe with brass unions :45 cm length, 20mm NB PWD CSR 2023-24, Vol-II, P. No. 118, I. No. 13.8.2.2 | No. | 113.3 | 113.3 | 14.0 | False | None | None | False | None | False | 1586.2 | 0 | | 3852586 | 147244 | None | code32 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet - 100 mm diameter PWD CSR 2023-24, Vol-II, P. No. 118, I. No. 13.9.1 | No. | 264.71 | 264.71 | 2.0 | False | None | None | False | None | False | 529.42 | 0 | | 3852587 | 147244 | None | code33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cuttingchases and making good the walls etc. PWD CSR 2023-24, Vol-II, P. No. 122, I. No. 13.32.3 | m | 491.31 | 491.31 | 40.0 | False | None | None | False | None | False | 19652.4 | 0 | | 3852588 | 147244 | None | code34 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work PWD CSR 2023-24,Vol-II, P. No. 122, I. No. 13.33.4 | m | 383.16 | 383.16 | 40.0 | False | None | None | False | None | False | 15326.4 | 0 | | 3852589 | 147244 | None | code35 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.. PWD CSR 2023-24, Vol-II, P. No. 123, I. No. | Ltr | 9.27 | 9.27 | 2000.0 | False | None | None | False | None | False | 18540.0 | 0 | | 3852590 | 147244 | None | code36 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 type A, including jointing with seal ring conforming to IS 5382, leaving 10mm gap for thermal expansion, (i) single socketed pipes 100 mm diameter PWD CSR 2023-24, Vol-II, P. No.125, I. No. 13.48 | m | 299.73 | 299.73 | 14.4 | False | None | None | False | None | False | 4316.112 | 0 | | 3852591 | 147244 | None | code37 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements
& all necessary accessories complete PWD CSR 2023-24, Vol-II, P. No. 127, I. No. 13.59 | No. | 226.6 | 226.6 | 20.0 | False | None | None | False | None | False | 4532.0 | 0 | | 3852592 | 147244 | None | code38 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (PWD CSR 2023-24, Vol-II, P. No.131, I. No. 14.1.1) | No. | 5030.52 | 5030.52 | 2.0 | False | None | None | False | None | False | 10061.04 | 0 | | 3852593 | 147244 | None | code39 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid PWD CSR 2023-24, Vol-II, P. No. 131, I. | No. | 6156.31 | 6156.31 | 7.0 | False | None | None | False | None | False | 43094.17 | 0 | | 3852594 | 147244 | None | code40 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps PWD CSR 2023-24, Vol-II, P. No. 132, I. No. 14.7.1 | No. | 3174.46 | 3174.46 | 6.0 | False | None | None | False | None | False | 19046.76 | 0 | | 3852595 | 147244 | None | code41 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm (PWD CSR 2023-24, Vol-II, P. No. 136, I. No. 14.32.4 | Each | 1777.78 | 1777.78 | 4.0 | False | None | None | False | None | False | 7111.12 | 0 | | 3852596 | 147244 | None | code42 | Providing and fixing Single Lever Basin Mixer with 450mm long flexible connectors made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete -
Class Economy Class PWD CSR 2023-24, Vol-II, P. No. 139, I. No. 14.55a | Each | 2546.16 | 2546.16 | 6.0 | False | None | None | False | None | False | 15276.96 | 0 | | 3852597 | 147244 | None | code43 | Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed
fitting arrangements & all necessary accesories complete Economy Class PWD CSR 2023-24, Vol-II, P. No. 139, I. No. 14.55a | Each | 1150.51 | 1150.51 | 10.0 | False | None | None | False | None | False | 11505.1 | 0 | | 3852598 | 147244 | None | code44 | Providing and fixing Single lever wall mixer with L shaped Tubular bend set for overhead
shower made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class a Economy PWD CSR 2023-24, Vol-II, P. No. 140, I. No. 14.60a | Each | 4104.55 | 4104.55 | 2.0 | False | None | None | False | None | False | 8209.1 | 0 | | 3852599 | 147244 | None | code45 | Providing and fixing Towel rail 600mm length made of Stainless steel with all concealed fitting
arrangements & all necessary accesories complete Economy PWD CSR 2023-24, Vol-II, P. No. 144, I. No. 14.89a | Each | 1299.86 | 1299.86 | 2.0 | False | None | None | False | None | False | 2599.72 | 0 | | 3852600 | 147244 | None | code46 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting
arrangements & all necessary accesories complete - Class Economy PWD CSR 2023-24, Vol-II, P. No. 144, I. No. 14.83a | No. | 564.44 | 564.44 | 9.0 | False | None | None | False | None | False | 5079.96 | 0 | | 3852601 | 147244 | None | code47 | Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting
arrangements & all necessary accesories complete - Class a Economy PWD CSR 2023-24, Vol- II, P. No. 144, I. No. 14.85a | No. | 1798.38 | 1798.38 | 4.0 | False | None | None | False | None | False | 7193.52 | 0 | | 3852602 | 147244 | None | code48 | Providing and fixing Toilet paper holder made of Stainless steel with all concealed fitting
arrangements & all necessary accesories complete - Class a Economy PWD CSR 2023-24, Vol- II, P. No. 145, I. No. 14.93a | No. | 864.17 | 864.17 | 9.0 | False | None | None | False | None | False | 7777.53 | 0 | | 3852603 | 147244 | None | code49 | Providing and fixing Bidet spray made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class a Economy PWD CSR 2023-24, Vol-II, P. No. 145, I. No. 14.95a | No. | 864.17 | 864.17 | 9.0 | False | None | None | False | None | False | 7777.53 | 0 | | 3852604 | 147244 | None | code50 | Providing and fixing Stainless Steel Grab Bar 600 mm Long with all concealed fitting
arrangements & all necessary accesories complete - Class a Economy PWD CSR 2023-24, Vol- II, P. No. 145, I. No. 14.96a | No. | 2010.56 | 2010.56 | 9.0 | False | None | None | False | None | False | 18095.04 | 0 | | 3852605 | 147244 | None | code51 | Providing and fixing Soap dish wired with 200mm width made of Stainless steel with all
concealed fitting arrangements & all necessary accesories complete - Class a Economy PWD CSR 2023-24, Vol-II, P. No. 145, I. No. 14.92a | No. | 739.54 | 739.54 | 2.0 | False | None | None | False | None | False | 1479.08 | 0 | | 3852606 | 147244 | None | code52 | Providing and supplying cupboard shutter with 19mm thick one side Architect recommended decorative laminate (1mm thick) and other side balancing lamination(preferably white) on factory pressed bwp grade marine ply as per IS 710 of approved brand complete as per direction of engineer in-charge.(Payment for providing and fixing auto closing hinges shall be paid separately) PWD CSR 2023-24, Vol-II, P. No. 217, I. No. 22.3 | No. | 3048.8 | 3048.8 | 8.64 | False | None | None | False | None | False | 26341.632 | 0 | | 3852607 | 147244 | None | code53 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mmsizes respectively with automatic flushing cistern with standard flushpipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern (PWD CSR 2023-24, Vol-II, P. No. 131, I. No. 14.4.1) | No. | 4587.62 | 4587.62 | 4.0 | False | None | None | False | None | False | 18350.48 | 0 | | 3852608 | 147244 | None | code54 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof includingjointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from theexcavationetc. complete. 110mm(weight of pipe - 1.315 kg) (p.no.120. it.no 10.14.4) 2023-24 WATER SUPPLY AND UGD WORKS COMMON SCHEDULE OF RATES VOLUME-V | m | 290.46 | 290.46 | 50.0 | False | None | None | False | None | False | 14523.0 | 0 | | 3852609 | 147244 | None | code55 | Concealed PVC Conduit System Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. Theconduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 1.2.1 19/20 mm dia 2 mm thick (P.no.2.it.no.1.2.1) (PWD CSR for ElectricalWorks for the Year 2023-24) | Mtr | 66.0 | 66.0 | 75.0 | False | None | None | False | None | False | 4950.0 | 0 | | 3852610 | 147244 | None | code56 | Supplying heavy gauge PVC Conduit Pipe .... dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 1.3.1 19/20 mm dia 2 mm thick (P.no.2.it.no.1.3.1)
(PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 68.0 | 68.0 | 50.0 | False | None | None | False | None | False | 3400.0 | 0 | | 3852611 | 147244 | None | code57 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete 1.7.1 upto 50 mm conduit in brick wall (P.no.3.it.no.1.7) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 29.0 | 29.0 | 50.0 | False | None | None | False | None | False | 1450.0 | 0 | | 3852612 | 147244 | None | code58 | PVC/metal conduit Deep Junction Box Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction Box (P.no.2.it.no.1.5) (PWD CSR for Electrical Works for the Year 2023-24) | Nos | 49.0 | 49.0 | 10.0 | False | None | None | False | None | False | 490.0 | 0 | | 3852613 | 147244 | None | code59 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in
Brick/Stone/C.C wall (P.no.8.it.no.3.4) 3.4.5 8 Way (PWD CSR for Electrical Works for the | Each | 261.0 | 261.0 | 6.0 | False | None | None | False | None | False | 1566.0 | 0 | | 3852614 | 147244 | None | code60 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in
Brick/Stone/C.C wall (P.no.8.it.no.3.4) 3.4.6 10-12 Way (PWD CSR for Electrical Works for | Each | 319.0 | 319.0 | 5.0 | False | None | None | False | None | False | 1595.0 | 0 | | 3852615 | 147244 | None | code61 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3.5.5 8 Module (P.no.8.it.no.3.5) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 284.0 | 284.0 | 6.0 | False | None | None | False | None | False | 1704.0 | 0 | | 3852616 | 147244 | None | code62 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete
on the existing metal/PVC box.3.5.6 10-12 Module (P.no.8.it.no.3.5) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 344.0 | 344.0 | 5.0 | False | None | None | False | None | False | 1720.0 | 0 | | 3852617 | 147244 | None | code63 | Point wiring using Copper wire without switch.2.2 Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS- 694: and latest amendments) withoutcontrol switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient looselength in a wood/PVC round
block. complete for each outlet. 2.2.1 Short point upto 3Mtr from tapping point to out let | Point | 269.0 | 269.0 | 12.0 | False | None | None | False | None | False | 3228.0 | 0 | | 3852618 | 147244 | None | code64 | Point wiring using Copper wire without switch.2.2 Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS- 694: and latest amendments) withoutcontrol switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient looselength in a wood/PVC round block. complete for each outlet. 2.2.2 Medium point above 3Mtr upto 6Mtr from tapping | Point | 379.0 | 379.0 | 12.0 | False | None | None | False | None | False | 4548.0 | 0 | | 3852619 | 147244 | None | code65 | Point wiring using Copper wire without switch.2.2 Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS- 694: and latest amendments) withoutcontrol switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient looselength in a wood/PVC round block. complete for each outlet. 2.2.3 Long point above 6Mtr upto 10Mtr from tapping | Point | 555.0 | 555.0 | 8.0 | False | None | None | False | None | False | 4440.0 | 0 | | 3852620 | 147244 | None | code66 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.2 1.5 mm
(P.no.5.it.no.2.3.2) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 26.0 | 26.0 | 150.0 | False | None | None | False | None | False | 3900.0 | 0 | | 3852621 | 147244 | None | code67 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 Sqmm
(P.no.5.it.no.2.3.3) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 42.0 | 42.0 | 300.0 | False | None | None | False | None | False | 12600.0 | 0 | | 3852622 | 147244 | None | code68 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 Sqmm (P.no.5.it.no.2.3.4) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 63.0 | 63.0 | 200.0 | False | None | None | False | None | False | 12600.0 | 0 | | 3852623 | 147244 | None | code69 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one
way (P.no.9.it.no.3.6.1) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 102.0 | 102.0 | 30.0 | False | None | None | False | None | False | 3060.0 | 0 | | 3852624 | 147244 | None | code70 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 3.6.3 A
Three Way socket(P.no.9.it.no.3.6.3) (PWD CSR for Electrical Works for the Year 2023- | Each | 171.0 | 171.0 | 12.0 | False | None | None | False | None | False | 2052.0 | 0 | | 3852625 | 147244 | None | code71 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps
one way switch (P.no.9.it.no.3.6.7) .(PWD CSR for Electrical Works for the Year 2023-24) | Each | 180.0 | 180.0 | 6.0 | False | None | None | False | None | False | 1080.0 | 0 | | 3852626 | 147244 | None | code72 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 12933.6.10 6/16A Universal Socket. (P.no.9.it.no.3.6.10) (PWD CSR for Electrical Works for the Year 2023 | Each | 236.0 | 236.0 | 6.0 | False | None | None | False | None | False | 1416.0 | 0 | | 3852627 | 147244 | None | code73 | 4mm Thick Plastic Sheets Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. (P.no.9.it.no.3.8) (PWD CSR for Electrical Works for the Year 2023-24) | Sqm | 4100.0 | 4100.0 | 0.2 | False | None | None | False | None | False | 820.0 | 0 | | 3852628 | 147244 | None | code74 | Porcelain Fuse Channel Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32Amps
(P.no.14.it.no.5.7.2) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 241.0 | 241.0 | 6.0 | False | None | None | False | None | False | 1446.0 | 0 | | 3852629 | 147244 | None | code75 | Miniature Circuit Breakers Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps SP (p.no.17.it.no.5.18) (PWD CSR for Electrical Works
for the Year 2023-24) | Each | 415.0 | 415.0 | 8.0 | False | None | None | False | None | False | 3320.0 | 0 | | 3852630 | 147244 | None | code76 | Miniature Circuit Breakers Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DP .(p.no.17.it.no.5.18.4) (PWD CSR for Electrical
Works for the Year 2023-24) | Each | 739.0 | 739.0 | 5.0 | False | None | None | False | None | False | 3695.0 | 0 | | 3852631 | 147244 | None | code77 | MCB Distribution Boards Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door 8 Way SP & N
(p.no.18.it.no.5.19.8)(PWD CSR for Electrical Works for the Year 2023-24) | Each | 1854.0 | 1854.0 | 2.0 | False | None | None | False | None | False | 3708.0 | 0 | | 3852632 | 147244 | None | code78 | PVC Batten with LED Tubes Supplying of ......feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 11.3.3LED light fitting 1 x 4' - 36/40 W.no.43.it.no.11.3.3) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 1269.0 | 1269.0 | 16.0 | False | None | None | False | None | False | 20304.0 | 0 | | 3852633 | 147244 | None | code79 | LED Down Lights Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor
0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W (p.no.43.it.no.11.5.3) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 1324.0 | 1324.0 | 16.0 | False | None | None | False | None | False | 21184.0 | 0 | | 3852634 | 147244 | None | code80 | Lamp Holder Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 3.14.7 6A Batten Holder(p.no.10.it.no.3.14.7) (PWD CSR for Electrical Works
for the Year 2023-24) | No | 74.0 | 74.0 | 16.0 | False | None | None | False | None | False | 1184.0 | 0 | | 3852635 | 147244 | None | code81 | Fixing all type of Luminaries Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling /
Rafter / Girders (p.no.56.it.no.13.7.1) (PWD CSR for Electrical Works for the Year 2023- | Each | 122.0 | 122.0 | 16.0 | False | None | None | False | None | False | 1952.0 | 0 | | 3852636 | 147244 | None | code82 | Fixing of LED Lights Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and
clamps..(p.no.58.it.no.13.19) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 490.0 | 490.0 | 16.0 | False | None | None | False | None | False | 7840.0 | 0 | | 3852637 | 147244 | None | code83 | Supplyingexhaustfanof1440RPMof300mm(12")sizewithbracketbladescompleteforlightdu tysuitabletooperateon230V50Hz, AC Supply. (PWD CSR for Electrical Works for the Year 2023-24 P.no.30.it.no.6.1) | Each | 1492.0 | 1492.0 | 12.0 | False | None | None | False | None | False | 17904.0 | 0 | | 3852638 | 147244 | None | code84 | Supplyingwallmountingfansuitabletooperateatsingle-phase230v AC. supply. 6.5.2
400 mm Sweep (PWD CSR for Electrical Works for the Year 2023-24 | Each | 3212.0 | 3212.0 | 2.0 | False | None | None | False | None | False | 6424.0 | 0 | | 3852639 | 147244 | None | code85 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5A. Ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core
wire...(p.no.58.it.no.13.14) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 492.0 | 492.0 | 12.0 | False | None | None | False | None | False | 5904.0 | 0 | | 3852640 | 147244 | None | code86 | Fixing a ceiling/wal lmounting fan of all capacities andalltypes,withnecessaryclampsand'S'hookmade outof15mmdiaMSrod,with5A.ceilingroseofapprovedqualitywithnecessarylengthof23/0.0076inc hPVCinsulatedtwintwistedwireofapprovedquality,mounted on a suitable size wooden board and
wired.(p.no.58.it.no.13.11) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 315.0 | 315.0 | 2.0 | False | None | None | False | None | False | 630.0 | 0 | | 3852641 | 147244 | None | code87 | Supplying,fixingandwiringElectronicTrivectorMeter(ETV)5to32/63Athreephase4wirewh olecurrentclass-1AccuracyEnergyMeter. (PWD CSR for Electrical Works for the Year 2023-24 P.no.30.it.no.5.35) | Each | 5705.0 | 5705.0 | 1.0 | False | None | None | False | None | False | 5705.0 | 0 | | 3852642 | 147244 | None | code88 | FabricatingsupplyingandmountingMSboxmadeout SWG suitable for floor/ wall mounting, f
ullyweatherproofwithprovisionforbetterheatdissipation,providedwithhingedfrontcover,e quippedwithtamper prooflockingarrangements,withsuitablesizeclampswithnecessarycabl eentry pipe with glandandbox shouldbefinishedwith7tankstreatmentwithpowdercoatedpai ntand finally finished with approved colour etc., complete.
5.42.114 SWG. (PWD CSR for Electrical Works for the Year 2023-24 | Sqm | 5000.0 | 5000.0 | 1.85 | False | None | None | False | None | False | 9250.0 | 0 | | 3852643 | 147244 | None | code89 | Supplying Arated 3phase with neutralbusbarusingrequiredcapacityelectrolyticaluminiu mstripscoveredwithheatshrinkablecoloured PVCsleeve,mountedonphenolic/FRP/DMCins ulatorwhicharemountedonpowdercoated40x6mmM.S.flatframeworkinexistingpanelboar d.ThebusbarshallhavesuitableholesforterminationofincomingandoutgoingcablesasperISs pecification with necessary bolts, nuts and washers etc., complete5 40.1100 A 4 x 30 x 6
mm Aluminium Strips (PWD CSR for Electrical Works for the Year 2023-24 | Mtr | 2465.0 | 2465.0 | 0.5 | False | None | None | False | None | False | 1232.5 | 0 | | 3852644 | 147244 | None | code90 | Supplying,fixing,wiring,earthelectrodeforgroundingconduits,I.C.cutoutsandothereq uipment'sonthemeterboardusing40mmdia2.90mmthickGIpipe2.5mlongburiedinapi t.Thepitshouldbefilledwithequalproportionofsaltandcharcoal150mmall- roundthepipetocompletedepth.Theconnectionfromthepipetotheconduitetc.,istobees tablishedthroughGIwireofsizeasperlSIspecification7.3.3.ofIS732using12mmdiabolt s,nuts,washersandchecknutsetc., the pipe shall have 16 through holes of 12 mm dia
. (PWD CSR for Electrical Works for the Year 2023-24 P.no.54.it.no.12.56) | Each | 3510.0 | 3510.0 | 2.0 | False | None | None | False | None | False | 7020.0 | 0 | | 3852645 | 147244 | None | code91 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and 1.00 HP/0.75KW 7 STG (p.no.149. it.no
13.6.1) 2023-24 WATER SUPPLY AND UGD WORKS COMMON SCHEDULE OF RATES | Each | 14327.3 | 14327.3 | 1.0 | False | None | None | False | None | False | 14327.3 | 0 | | 3852646 | 147244 | None | code92 | Supplyingpushbuttonoperateddirectonlinestarterwithanantiweldsilvercadmiumoxi decontactorwithreplaceablefixedandmovingcontactsandbimetallicthermaloverload relayhelpinanticorrosiontreatedsheetsteelorironcladenclosureandfixingthesametos uitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP. . (PWD CSR for Electrical Works for the Year 2023-24 P.no.14.it.no.5.1) | Each | 1927.0 | 1927.0 | 1.0 | False | None | None | False | None | False | 1927.0 | 0 | | 3852647 | 147244 | None | code93 | Supplying,installation,testingandcommissioningofsolarhotwaterheatercomprisingo
fhighqualityEvacuatedGlassTube(EGT)withabsorbercoatingcollectorofsize58x1800 mm.InnertankMaterial-Stainlesssteel304- LGradewith Aluminium Stuccocladdingmade ofHighqualityPUFinsulationtominimize sheatlossandholdwaterTemperatureupto72Hrs...withappropriatecapacityelectrical backup arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode
7.4.2 200 L - 20 nos Tubes . (PWD CSR for Electrical Works for the Year 2023-24
P.no.35.it.no.7.4) | Each | 43222.0 | 43222.0 | 2.0 | False | None | None | False | None | False | 86444.0 | 0 | | 3852648 | 147244 | None | code94 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm)Pg No 13 It No 32.07 of Part III of BESCOM SR SR 2023-24 | Km | 139549.0 | 139549.0 | 0.07 | False | None | None | False | None | False | 9768.43 | 0 | | 3852649 | 147244 | None | code95 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden /Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 SqmmPg No 52 It No 21.05 of Part IV of BESCOM SR SR 2023-24 | Km | 20886.0 | 20886.0 | 0.07 | False | None | None | False | None | False | 1462.02 | 0 | | 3852650 | 147244 | None | code96 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. in all kind of soil depth upto 1.5 m(PWD CSR 2023- 24, Vol-II, P. No. 136, I. No.8.9) | CUBIC METER | 249.0 | 249.0 | 11.7 | False | None | None | False | None | False | 2913.3 | 0 | | 3852651 | 147244 | None | code97 | Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting as per IRC:67:2022 with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans. Aluminium Alloy Plate for Over Head Sign (PWD CSR 2023-24, Vol-II, P. No. 136, I. No.8.9) | Kg | 5992.54 | 5992.54 | 2.16 | False | None | None | False | None | False | 12943.8864 | 0 | | 3852652 | 147244 | None | code98 | Display Board Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. With approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge & MoRTH specification 804 (as per specification. PWD SR
2023-24 Vol:3 P.NO.78 I.No: 8.54) | No. | 9270.0 | 9270.0 | 1.0 | False | None | None | False | None | False | 9270.0 | 0 | | 3852653 | 147244 | None | code99 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete(as per specification. PWD SR 2023-24 Vol:2 P.NO.176 I.No: 17.12) | Sqm | 955.84 | 955.84 | 3.65 | False | None | None | False | None | False | 3488.816 | 0 | | 3852654 | 147244 | None | code100 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth 3 m to 6 m (as per specification. PWD SR 2023-24 Vol:1 P.NO.8 I.No: 1.14.2) | Cum | 120.51 | 120.51 | 5.04 | False | None | None | False | None | False | 607.3704 | 0 | | 3852655 | 147244 | None | code101 | Construction of rock fill embankment with broken hard rock fragments of size not exceeding 300 mm laid in layers not exceeding 500 mm thick including filling of surface voids with stone spalls, blinding top layer with granular material, rolled with vibratory road roller, all complete as per clause 313. (as per specification. PWD SR 2023-24 Vol:3 P.NO.18 I.No:3.12) | Cum | 150.38 | 150.38 | 0.432 | False | None | None | False | None | False | 64.96416 | 0 | | 3852656 | 147244 | None | code102 | Providing to work spot rolling, lowering and placing in position RCC perforated rings in the already excavated pit including loading and unloading at both the destinations with all lead and lift with
appurtenances., complete.900 mmx1100 mm. (as per specification.BWSSB SR 2023-24 Vol:5 P.NO.208 I.No:16.62.1) | Each | 6341.71 | 6341.71 | 3.0 | False | None | None | False | None | False | 19025.13 | 0 | | 3852657 | 147244 | None | code103 | Supply and fixing of SFRC machinhole cover (Medium Duty) made as per IS to suit existing damaged machinhole cover after removing the debries from inside and outside the existing machinhole etc. with all lead and lifts.heavy duty (as per specification.BWSSB SR 2023-24 Vol:5 P.NO.208 I.No:16.61.2) | Each | 1269.99 | 1269.99 | 1.0 | False | None | None | False | None | False | 1269.99 | 0 |
|