3835515 | 146279 | None | ITEMCODE1 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. 1.4.1 In all kinds of soils Depth upto 1.5 m as per directions of Engineer-in-charge. | Cum | 266.2 | 266.2 | 250.36 | False | None | None | False | None | False | 66645.832 | 0 |
3835516 | 146279 | None | ITEMCODE2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. as per directions of Engineer-in-charge. | Cum | 292.6 | 292.6 | 150.22 | False | None | None | False | None | False | 43954.372 | 0 |
3835517 | 146279 | None | ITEMCODE3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates as per directions of Engineer-in-charge. | Cum | 6230.4 | 6230.4 | 42.07 | False | None | None | False | None | False | 262112.928 | 0 |
3835518 | 146279 | None | ITEMCODE4 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per directions of Engineer-in-charge. | Cum | 7527.17 | 7527.17 | 21.3 | False | None | None | False | None | False | 160328.721 | 0 |
3835519 | 146279 | None | ITEMCODE5 | M25 Concrete for Plinth Beam as per directions of Engineer-in-charge. | Cum | 10454.4 | 10454.4 | 38.43 | False | None | None | False | None | False | 401762.592 | 0 |
3835520 | 146279 | None | ITEMCODE6 | M25 Concrete for Roof slab(FF)-as per directions of Engineer-in-charge. | Cum | 10524.1 | 10524.1 | 23.13 | False | None | None | False | None | False | 243422.433 | 0 |
3835521 | 146279 | None | ITEMCODE7 | M25 Concrete for Columns-as per directions of Engineer-in-charge. | Cum | 11848.32 | 11848.32 | 7.02 | False | None | None | False | None | False | 83175.2064 | 0 |
3835522 | 146279 | None | ITEMCODE8 | M25 Concrete for Columns(FF)-as per directions of Engineer-in-charge. | Cum | 11918.02 | 11918.02 | 7.02 | False | None | None | False | None | False | 83664.5004 | 0 |
3835523 | 146279 | None | ITEMCODE9 | M25 Concrete for Lintel Beam-as per directions of Engineer-in-charge. | Cum | 11151.36 | 11151.36 | 12.17 | False | None | None | False | None | False | 135712.0512 | 0 |
3835524 | 146279 | None | ITEMCODE10 | M25 Concrete for Lintel Beam(FF)-as per directions of Engineer-in-charge. | Cum | 11221.06 | 11221.06 | 8.51 | False | None | None | False | None | False | 95491.2206 | 0 |
3835525 | 146279 | None | ITEMCODE11 | M25 Concrete for Chajja -as per directions of Engineer-in-charge. | Cum | 10105.92 | 10105.92 | 1.34 | False | None | None | False | None | False | 13541.9328 | 0 |
3835526 | 146279 | None | ITEMCODE12 | M25 Concrete for Chajja(FF)-as per directions of Engineer-in-charge. | Cum | 10175.62 | 10175.62 | 1.34 | False | None | None | False | None | False | 13635.3308 | 0 |
3835527 | 146279 | None | ITEMCODE13 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings-as per directions of Engineer-in-charge. | Tonne | 98402.7 | 98402.7 | 9.09 | False | None | None | False | None | False | 894480.543 | 0 |
3835528 | 146279 | None | ITEMCODE14 | TMT Steel (FF) | Tonne | 99386.73 | 99386.73 | 4.14 | False | None | None | False | None | False | 411461.0622 | 0 |
3835529 | 146279 | None | ITEMCODE15 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1cement : 6 coarse sand)-as per directions of Engineer-in-charge. | Cum | 7027.0 | 7027.0 | 84.4 | False | None | None | False | None | False | 593078.8 | 0 |
3835530 | 146279 | None | ITEMCODE16 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely linx005f ing, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge -as per directions of Engineer-in-charge | Sqm | 280.5 | 280.5 | 173.12 | False | None | None | False | None | False | 48560.16 | 0 |
3835531 | 146279 | None | ITEMCODE17 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates -as per directions of Engineer-in-charge | Cum | 6867.3 | 6867.3 | 23.13 | False | None | None | False | None | False | 158840.649 | 0 |
3835532 | 146279 | None | ITEMCODE18 | M15 Concrete for Flooring (ff) | Cum | 6935.97 | 6935.97 | 23.13 | False | None | None | False | None | False | 160428.9861 | 0 |
3835533 | 146279 | None | ITEMCODE19 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo- textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.-as per directions of Engineer-in-charge | Sqm | 819.5 | 819.5 | 154.2 | False | None | None | False | None | False | 126366.9 | 0 |
3835534 | 146279 | None | ITEMCODE20 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications-as per directions of Engineer-in-charge | Sqm | 1322.2 | 1322.2 | 266.22 | False | None | None | False | None | False | 351996.084 | 0 |
3835535 | 146279 | None | ITEMCODE21 | 8-inch Block for Wall | Sqm | 1335.42 | 1335.42 | 352.8 | False | None | None | False | None | False | 471136.176 | 0 |
3835536 | 146279 | None | ITEMCODE22 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 337.7 | 337.7 | 266.22 | False | None | None | False | None | False | 89902.494 | 0 |
3835537 | 146279 | None | ITEMCODE23 | Outside Plastering Engineer-in-charge. | Sqm | 341.08 | 341.08 | 352.8 | False | None | None | False | None | False | 120333.024 | 0 |
3835538 | 146279 | None | ITEMCODE24 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 278.3 | 278.3 | 266.22 | False | None | None | False | None | False | 74089.026 | 0 |
3835539 | 146279 | None | ITEMCODE25 | Inside Plastering-Engineer-in-charge. | Sqm | 281.08 | 281.08 | 266.22 | False | None | None | False | None | False | 74829.1176 | 0 |
3835540 | 146279 | None | ITEMCODE26 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge-Engineer-in-charge. | Sqm | 239.8 | 239.8 | 154.2 | False | None | None | False | None | False | 36977.16 | 0 |
3835541 | 146279 | None | ITEMCODE27 | Ceiling Plastering-Engineer-in-charge. | Sqm | 242.2 | 242.2 | 154.2 | False | None | None | False | None | False | 37347.24 | 0 |
3835542 | 146279 | None | ITEMCODE28 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 91.3 | 91.3 | 2919.72 | False | None | None | False | None | False | 266570.436 | 0 |
3835543 | 146279 | None | ITEMCODE29 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. | Sqm | 104.5 | 104.5 | 1151.46 | False | None | None | False | None | False | 120327.57 | 0 |
3835544 | 146279 | None | ITEMCODE30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 149.6 | 149.6 | 532.44 | False | None | None | False | None | False | 79653.024 | 0 |
3835545 | 146279 | None | ITEMCODE31 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 3137.2 | 3137.2 | 195.63 | False | None | None | False | None | False | 613730.436 | 0 |
3835546 | 146279 | None | ITEMCODE32 | Granite Flooring (FF)-by the Engineer-in-Charge | Sqm | 3168.57 | 3168.57 | 115.91 | False | None | None | False | None | False | 367268.9487 | 0 |
3835547 | 146279 | None | ITEMCODE33 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm Maximum possible size 1819mmx1819mm The cost is inclusive of all fixtures and separate charges for minor T Ps shall not be made Engineer-in-Charge | Sqm | 6426.2 | 6426.2 | 30.24 | False | None | None | False | None | False | 194328.288 | 0 |
3835548 | 146279 | None | ITEMCODE34 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.-Engineer-in-Charge | Each | 99432.2 | 99432.2 | 0.54 | False | None | None | False | None | False | 53693.388 | 0 |
3835549 | 146279 | None | ITEMCODE35 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications.-Engineer-in-Charge | Sqm | 5581.4 | 5581.4 | 13.23 | False | None | None | False | None | False | 73841.922 | 0 |
3835550 | 146279 | None | ITEMCODE36 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc..-Engineer-in-Charge | Each | 41.8 | 41.8 | 25.0 | False | None | None | False | None | False | 1045.0 | 0 |
3835551 | 146279 | None | ITEMCODE37 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete..-Engineer-in-Charge | Each | 915.2 | 915.2 | 25.0 | False | None | None | False | None | False | 22880.0 | 0 |
3835552 | 146279 | None | ITEMCODE38 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete-Engineer-in-Charge | Each | 122.1 | 122.1 | 25.0 | False | None | None | False | None | False | 3052.5 | 0 |
3835553 | 146279 | None | ITEMCODE39 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete-Engineer-in-Charge | Each | 122.1 | 122.1 | 25.0 | False | None | None | False | None | False | 3052.5 | 0 |
3835554 | 146279 | None | ITEMCODE40 | Concealed Conduit System: Supplying … . Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary -Engineer-in-Charge | m | 70.0 | 70.0 | 500.0 | False | None | None | False | None | False | 35000.0 | 0 |
3835555 | 146279 | None | ITEMCODE41 | Supplying heavy gauge PVC Conduit Pipe .... dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.-Engineer-in-Charge | m | 80.0 | 80.0 | 400.0 | False | None | None | False | None | False | 32000.0 | 0 |
3835556 | 146279 | None | ITEMCODE42 | Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Point wiring using Copper wire without Switch.-Engineer-in-Charge | Nos | 361.0 | 361.0 | 24.0 | False | None | None | False | None | False | 8664.0 | 0 |
3835557 | 146279 | None | ITEMCODE43 | Suppling and fixing PVC/metal conduit deep juction boxes-Engineer-in-Charge | Each | 51.0 | 51.0 | 42.0 | False | None | None | False | None | False | 2142.0 | 0 |
3835558 | 146279 | None | ITEMCODE44 | Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-3.4.1) 1-3Way-Engineer-in-Charge- | Each | 123.0 | 123.0 | 25.0 | False | None | None | False | None | False | 3075.0 | 0 |
3835559 | 146279 | None | ITEMCODE45 | 3.4.2) 4-5Way-Engineer-in-Charge- | Each | 138.0 | 138.0 | 24.0 | False | None | None | False | None | False | 3312.0 | 0 |
3835560 | 146279 | None | ITEMCODE46 | Wiring for lighting /power circuit using one of PVC insulated 1100v grade,multis and Copper conductor single core cable in open or consealed system of wiring.Engineer-in-Charge | m | 40.0 | 40.0 | 400.0 | False | None | None | False | None | False | 16000.0 | 0 |
3835561 | 146279 | None | ITEMCODE47 | Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/ telephone socket etc on existing modular switch plate.3.6.1) 6A mps one way-Engineer-in-Charge | Each | 88.0 | 88.0 | 120.0 | False | None | None | False | None | False | 10560.0 | 0 |
3835562 | 146279 | None | ITEMCODE48 | 3.6.2) 6A mps Two way-Engineer-in-Charge | Each | 152.0 | 152.0 | 100.0 | False | None | None | False | None | False | 15200.0 | 0 |
3835563 | 146279 | None | ITEMCODE49 | Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal /PVC box-3.5.1) 1 to 3 Module | Each | 152.0 | 152.0 | 16.0 | False | None | None | False | None | False | 2432.0 | 0 |
3835564 | 146279 | None | ITEMCODE50 | 3.5.3) 6 Module | Each | 244.0 | 244.0 | 12.0 | False | None | None | False | None | False | 2928.0 | 0 |
3835565 | 146279 | None | ITEMCODE51 | Supplying and fixing regular MCB distribution boards on wall/ woodboard /flush mounting required clamps, bolts,nuts etc.. with provision for fixing suitable type capacity MCB's single phase /3 phase / single door with powder coated painting etc., complete | Each | 1695.0 | 1695.0 | 12.0 | False | None | None | False | None | False | 20340.0 | 0 |
3835566 | 146279 | None | ITEMCODE52 | 5.18.8) 12Way SP & N | Each | 2067.0 | 2067.0 | 8.0 | False | None | None | False | None | False | 16536.0 | 0 |
3835567 | 146279 | None | ITEMCODE53 | Supplying and fixing and wiring Earth Leakage Miniature Circuit Breaker [RCCB] 240/450V up 300mA sensitivity on exsiting wood/panel board. | Each | 4831.0 | 4831.0 | 12.0 | False | None | None | False | None | False | 57972.0 | 0 |
3835568 | 146279 | None | ITEMCODE54 | 5.19.3)32-40 Amps 4 Pole | Each | 4677.0 | 4677.0 | 12.0 | False | None | None | False | None | False | 56124.0 | 0 |
3835569 | 146279 | None | ITEMCODE55 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | Each | 2999.7 | 2999.7 | 8.0 | False | None | None | False | None | False | 23997.6 | 0 |
3835570 | 146279 | None | ITEMCODE56 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Each | 4150.0 | 4150.0 | 12.0 | False | None | None | False | None | False | 49800.0 | 0 |
3835571 | 146279 | None | ITEMCODE57 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required | Each | 118.0 | 118.0 | 500.0 | False | None | None | False | None | False | 59000.0 | 0 |
3835572 | 146279 | None | ITEMCODE58 | Supplying of recess mounting non integrated type LED down light 15-18W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. | Each | 2174.0 | 2174.0 | 80.0 | False | None | None | False | None | False | 173920.0 | 0 |
3835573 | 146279 | None | ITEMCODE59 | Fixing all types and all capacities of fluorescent / fales ceiling /spot light /CFL / LED fittings indoor on the wall /ceiling / refters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps | Each | 119.0 | 119.0 | 80.0 | False | None | None | False | None | False | 9520.0 | 0 |
3835574 | 146279 | None | ITEMCODE60 | Supplying exhaust fan of 1440 RPM of 300 mm (12'') size with bracket blades complete for light duty suitable for operate of 230V 50Hz, AC Supply. | Each | 1542.0 | 1542.0 | 25.0 | False | None | None | False | None | False | 38550.0 | 0 |
3835575 | 146279 | None | ITEMCODE61 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. | Each | 110.0 | 110.0 | 25.0 | False | None | None | False | None | False | 2750.0 | 0 |
3835576 | 146279 | None | ITEMCODE62 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double bail bearing system. 48" Sweep | Each | 2949.0 | 2949.0 | 25.0 | False | None | None | False | None | False | 73725.0 | 0 |
3835577 | 146279 | None | ITEMCODE63 | Fixing a ceiling / wall mounting fan of all capacities and all types to the existing 's' hook with fan regulator to the existing board together with supplying and fixiting 5amps . Ceiling rose, necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring | Each | 150.0 | 150.0 | 25.0 | False | None | None | False | None | False | 3750.0 | 0 |
3835578 | 146279 | None | ITEMCODE64 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge | Kg | 149.6 | 149.6 | 4091.04 | False | None | None | False | None | False | 612019.584 | 0 |
3835579 | 146279 | None | ITEMCODE65 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum.(Tipper 14 m3) | Cum | 81.4 | 81.4 | 100.14 | False | None | None | False | None | False | 8151.396 | 0 |
3835580 | 146279 | None | ITEMCODE66 | Cost of Haulage Excluding Loading and Unloading Taking output 25 t load and lead 10 km = 250 t.km | T.Km | 105.6 | 105.6 | 100.14 | False | None | None | False | None | False | 10574.784 | 0 |