1724244771000 | 0 | None | None | Buildings | Construction of Proposed 21TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY & SECONDARY SHED) At CMC, Doddaballapur | 22894848.42 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3831160 | 146006 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR) | Cum | 105.06 | 105.06 | 253.9 | False | None | None | False | None | False | 26674.734 | 0 | 3831161 | 146006 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR) | Cum | 5833.92 | 5833.92 | 200.33 | False | None | None | False | None | False | 1168709.1936 | 0 | 3831162 | 146006 | None | code03 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) Footing | Cum | 7208.35 | 7208.35 | 307.89 | False | None | None | False | None | False | 2219378.8815 | 0 | 3831163 | 146006 | None | code04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) Column base | Cum | 11346.48 | 11346.48 | 31.72 | False | None | None | False | None | False | 359910.3456 | 0 | 3831164 | 146006 | None | code05 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115) | Cum | 9694.08 | 9694.08 | 20.13 | False | None | None | False | None | False | 195141.8304 | 0 | 3831165 | 146006 | None | code06 | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour,cleaning,straightening,cutting, bending, hooking, laping /welding joints,tying with binding wire/soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR) | Tonne | 92140.71 | 92140.71 | 21.7629 | False | None | None | False | None | False | 2005249.057659 | 0 | 3831166 | 146006 | None | code07 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR) | Cum | 6580.67 | 6580.67 | 91.28 | False | None | None | False | None | False | 600683.5576 | 0 | 3831167 | 146006 | None | code08 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR) | Cum | 488.22 | 488.22 | 1561.16 | False | None | None | False | None | False | 762189.5352 | 0 | 3831168 | 146006 | None | code09 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR) | Sqm | 1267.93 | 1267.93 | 428.76 | False | None | None | False | None | False | 543637.6668 | 0 | 3831169 | 146006 | None | code10 | Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2) | Sqm | 303.85 | 303.85 | 892.27 | False | None | None | False | None | False | 271116.2395 | 0 | 3831170 | 146006 | None | code11 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2) Calculation Enclosed | Kg | 116.39 | 116.39 | 86484.5 | False | None | None | False | None | False | 10065930.955 | 0 | 3831171 | 146006 | None | code12 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2) Turbo Vents | Each | 5000.0 | 5000.0 | 12.0 | False | None | None | False | None | False | 60000.0 | 0 | 3831172 | 146006 | None | code13 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2) | Sqm | 585.04 | 585.04 | 3264.62 | False | None | None | False | None | False | 1909933.2848 | 0 | 3831173 | 146006 | None | code14 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2) | Sqm | 103.0 | 103.0 | 892.27 | False | None | None | False | None | False | 91903.81 | 0 | 3831174 | 146006 | None | code15 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2) | No | 75.19 | 75.19 | 432.91 | False | None | None | False | None | False | 32550.5029 | 0 | 3831175 | 146006 | None | code16 | Wall painting with premium acrylic emulsion paint of interior grade,
having VOC (Volatile Organic Compound ) content less than 50 g/L of
approved brand and manufacture, including applying additional coats
wherever required to achieve even shade and colour. Two coats as per
specifications and as per directions of Engineer in charge.(Item No. 8.54.2, Page No. 50, Vol.2) | No | 113.3 | 113.3 | 395.87 | False | None | None | False | None | False | 44852.071 | 0 | 3831176 | 146006 | None | code17 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2) | Sqm | 2711.99 | 2711.99 | 57.38 | False | None | None | False | None | False | 155613.9862 | 0 | 3831177 | 146006 | None | code18 | Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2) | No | 25426.58 | 25426.58 | 3.0 | False | None | None | False | None | False | 76279.74 | 0 | 3831178 | 146006 | None | code19 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2) | Kg | 465.56 | 465.56 | 690.0 | False | None | None | False | None | False | 321236.4 | 0 | 3831179 | 146006 | None | code01 | Supply, erection, testing and commissioning of LT Control Panel panel cubicle type made out of 14/16 Swg MS CRCA sheet which is derusted,degreased, phosphated and passivated with angle iron skeleton or sheet folded construction. The panel to be dust and vermin proof type and with powder coated paint after suitable seven tank pretreatment. The panel will have individual compartments for incoming and outgoing feeders made out of cold rolled sheet and doors fitted with Neoprene gaskets and fasteners.The switchboards are to be tested as per IS 8623-1977 specifications.Busbars are to be of high conductivity Aluminium Alloy E91E IS 5082 specification. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height. Main Panel Incomer : MCCB TPN 200A with CBCT ELR & Ph indicators, meter section with all parameters as required, SE Approved Rate 200A 4 Wire 35kA 415V Aluminium busbars compartment. Outgoings: 100A TP MCCB feeder- 01No.Outgoings: 63A TP MCCB feeder- 01No.Outgoings: 40A TP MCCB feeder - 02Nos Outgoings: 25A TP MPCB feeder - 02Nos Outgoings: 16A DP MPCB feeder - 06Nos Outgoings: 63/40A MCB feeder- 10Nos | No | 175000.0 | 175000.0 | 1.0 | False | None | None | False | None | False | 175000.0 | 0 | 3831180 | 146006 | None | code02 | Supply, erection, testing and commissioning of LT Control Panel panel cubicle type made out of 14/16 Swg MS CRCA sheet which is derusted,degreased, phosphated and passivated with angle iron skeleton or sheet folded construction. The panel to be dust and vermin proof type and with powder coated paint after suitable seven tank pretreatment. The panel will have individual compartments for incoming and outgoing feeders made out of cold rolled sheet and doors fitted with Neoprene gaskets and fasteners.The switchboards are to be tested as per IS 8623-1977 specifications.Busbars are to be of high conductivity Aluminium Alloy E91E IS 5082 specification. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height. Sub panel-1 Incomer : MCB TPN 63A with CBCT ELR & Ph indicators, section with all parameters as required SE Approved Rate 63A 4 Wire 16kA 415V Aluminium busbars compartment.Outgoings: 40/63A 4P MCB feeder- 10Nos..Outgoings: 32A Industrial socket-04Nos.Outgoings: 16A Industrial socket-04Nos. | No | 75000.0 | 75000.0 | 2.0 | False | None | None | False | None | False | 150000.0 | 0 | 3831181 | 146006 | None | code03 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 150 Sqmm, 3.5 Core, (25 GI Strips - 4 x 0.8 mm) SL No 212., I.No.32.16,ESCOMs SR 2023-24 | Km | 571294.65 | 571294.65 | 0.2 | False | None | None | False | None | False | 114258.93 | 0 | 3831182 | 146006 | None | code04 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, 70 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm) SL No 209., I.No.32.13,ESCOMs SR 2023-24 | Km | 327449.36 | 327449.36 | 0.25 | False | None | None | False | None | False | 81862.34 | 0 | 3831183 | 146006 | None | code05 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) SL No 207., I.No.32.11,ESCOMs SR 2023-24 | Km | 184342.19 | 184342.19 | 0.165 | False | None | None | False | None | False | 30416.46135 | 0 | 3831184 | 146006 | None | code06 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm) SL No 204., I.No.32.08,ESCOMs SR 2023-24 | Km | 185239.32 | 185239.32 | 0.1 | False | None | None | False | None | False | 18523.932 | 0 | 3831185 | 146006 | None | code07 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) SL No 201., I.No.32.05,ESCOMs SR 2023-24 | Km | 141842.0 | 141842.0 | 0.175 | False | None | None | False | None | False | 24822.35 | 0 | 3831186 | 146006 | None | code08 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) SL No 199., I.No.32.03,ESCOMs SR 2023-24 | Km | 121544.12 | 121544.12 | 0.18 | False | None | None | False | None | False | 21877.9416 | 0 | 3831187 | 146006 | None | code09 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, 1.1 kV Class Armoured Aluminium Cable with
glands 4C x 6 Sq mm P.No.40, I.No.14.02,KPTCL SCHEDULE OF RATES 2023-24 | Mtr | 101.97 | 101.97 | 99.0 | False | None | None | False | None | False | 10095.03 | 0 | 3831188 | 146006 | None | code10 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, Supplying and drawing Flexible Multicore Cable manufactured
with electrolytic grade flexible copper with low conductor
confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed
suitable for working voltage upto 1100 Volts as per IS-694:1990 3C x 6 mm2 ,CSR Electrical SR-2023-24, ITEM NO:2.5.22 ,CH-2, PAGE NO-5 | Mtr | 260.59 | 260.59 | 300.0 | False | None | None | False | None | False | 78177.0 | 0 | 3831189 | 146006 | None | code11 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, 3C x 4 mm2 CSR Electrical SR-2023-24, ITEM NO:2.5.15 ,CH-2, PAGE NO-5 | Mtr | 177.16 | 177.16 | 250.0 | False | None | None | False | None | False | 44290.0 | 0 | 3831190 | 146006 | None | code12 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.3.5Cx150 Sqmm Al Ar cable | Set | 715.0 | 715.0 | 8.0 | False | None | None | False | None | False | 5720.0 | 0 | 3831191 | 146006 | None | code13 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 3Cx70 Sqmm Al Ar cable | Set | 455.0 | 455.0 | 8.0 | False | None | None | False | None | False | 3640.0 | 0 | 3831192 | 146006 | None | code14 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 3.5Cx50 Sqmm Al Ar cable | Set | 385.0 | 385.0 | 8.0 | False | None | None | False | None | False | 3080.0 | 0 | 3831193 | 146006 | None | code15 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 4Cx25 Sqmm Al Ar cable | Set | 250.0 | 250.0 | 10.0 | False | None | None | False | None | False | 2500.0 | 0 | 3831194 | 146006 | None | code16 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 4Cx16 Sqmm Al Ar cable | Set | 225.0 | 225.0 | 12.0 | False | None | None | False | None | False | 2700.0 | 0 | 3831195 | 146006 | None | code17 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 4Cx10 Sqmm Cu Ar cable | Set | 200.0 | 200.0 | 14.0 | False | None | None | False | None | False | 2800.0 | 0 | 3831196 | 146006 | None | code18 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 4Cx6.0 Sqmm Cu Ar cable | Set | 185.0 | 185.0 | 14.0 | False | None | None | False | None | False | 2590.0 | 0 | 3831197 | 146006 | None | code19 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 3Cx6.0 Sqmm Cu Un Ar cable | Set | 145.0 | 145.0 | 16.0 | False | None | None | False | None | False | 2320.0 | 0 | 3831198 | 146006 | None | code20 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 3Cx4.0 Sqmm Cu Un Ar cable | Set | 138.0 | 138.0 | 12.0 | False | None | None | False | None | False | 1656.0 | 0 | 3831199 | 146006 | None | code21 | Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. Pre - Insulated Lug - CPTAU for 70 Sqmm (SL No 321., I.No.43.23,ESCOMs SR 2023-24) | No | 352.26 | 352.26 | 8.0 | False | None | None | False | None | False | 2818.08 | 0 | 3831200 | 146006 | None | code22 | Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. Pre - Insulated Lug - CPTAU for 25 Sqmm (SL No 323., I.No.43.25,ESCOMs SR 2023-24) | Set | 295.61 | 295.61 | 8.0 | False | None | None | False | None | False | 2364.88 | 0 | 3831201 | 146006 | None | code23 | Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.Pre - Insulated Lug - CPTAU for 16 Sqmm (SL No 324., I.No.43.26,ESCOMs SR 2023-24) | Set | 146.26 | 146.26 | 8.0 | False | None | None | False | None | False | 1170.08 | 0 | 3831202 | 146006 | None | code24 | Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 10 Sqmm Cu Ar cable (tinned copper lug) | Set | 10.0 | 10.0 | 8.0 | False | None | None | False | None | False | 80.0 | 0 | 3831203 | 146006 | None | code25 | Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 6.0 Sqmm Cu Ar cable (tinned copper lug) | Set | 10.0 | 10.0 | 8.0 | False | None | None | False | None | False | 80.0 | 0 | 3831204 | 146006 | None | code26 | Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 6.0 Sqmm Cu Un Ar cable (tinned copper lug) | Set | 10.0 | 10.0 | 8.0 | False | None | None | False | None | False | 80.0 | 0 | 3831205 | 146006 | None | code27 | Supply & installation of Tinned Copper lugs crimping & wiring to terminal point. 4.0 Sqmm Cu Un Ar cable (tinned copper lug) | Set | 10.0 | 10.0 | 8.0 | False | None | None | False | None | False | 80.0 | 0 | 3831206 | 146006 | None | code28 | PVC conduits & Accessories, Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Ele SR, 19/20mm dia PVC 2mm thick conduit (CSR Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-1) | Mtr | 71.07 | 71.07 | 1000.0 | False | None | None | False | None | False | 71070.0 | 0 | 3831207 | 146006 | None | code29 | PVC conduits & Accessories, Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Ele SR 2023-24, Page No-2, Item 1.1, 25mm dia PVC 2mm thick conduit (CSR Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-1 ) | Mtr | 83.43 | 83.43 | 1200.0 | False | None | None | False | None | False | 100116.0 | 0 | 3831208 | 146006 | None | code30 | PVC conduits & Accessories, Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Ele SR 2023-24, Page No-2, Item 1.1, 32mm dia PVC 2.5mm thick conduit (CSR Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-1 ) | Mtr | 109.18 | 109.18 | 600.0 | False | None | None | False | None | False | 65508.0 | 0 | 3831209 | 146006 | None | code31 | PVC conduits & Accessories, Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Ele SR 2023-24, Page No-2, Item 1.1, 40mm dia PVC 2mm thick conduit (CSR Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-1) | Mtr | 153.47 | 153.47 | 800.0 | False | None | None | False | None | False | 122776.0 | 0 | 3831210 | 146006 | None | code32 | Point wiring using Copper wire with switch, Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral)&1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copperwire (confirming to IS-694:and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Ele SR 2023-24, Page No-5, Item 2.1, Short point upto 3Mtr from tapping point to out let via switch (CSR Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-2, PAGE NO-4) | No | 293.55 | 293.55 | 2.0 | False | None | None | False | None | False | 587.1 | 0 | 3831211 | 146006 | None | code33 | Point wiring using Copper wire with switch, Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral)&1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copperwire (confirming to IS-694:and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Ele SR 2023-24, Page No-5, Item 2.1, Medium point above 3Mtr upto 6Mtr from tapping point to out let
via switch (CSR Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-2, PAGE NO-4) | No | 405.82 | 405.82 | 5.0 | False | None | None | False | None | False | 2029.1 | 0 | 3831212 | 146006 | None | code34 | Point wiring using Copper wire with switch, Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral)&1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copperwire (confirming to IS-694:and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Ele SR 2023-24, Page No-5, Item 2.1, Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch (CSR Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-2, PAGE NO-4) | No | 587.1 | 587.1 | 17.0 | False | None | None | False | None | False | 9980.7 | 0 | 3831213 | 146006 | None | code35 | Point wiring using Copper wire with switch, Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral)&1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copperwire (confirming to IS-694:and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Ele SR 2023-24, Page No-5, Item 2.1, Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to
out let via switches. (CSR Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-2, PAGE NO-4) | No | 729.24 | 729.24 | 4.0 | False | None | None | False | None | False | 2916.96 | 0 | 3831214 | 146006 | None | code36 | Point wiring using Copper wire with switch, Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral)&1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copperwire (confirming to IS-694:and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Ele SR 2023-24, Page No-5, Item 2.1, Three outlet in a row, above 6Mts upto 10Mtr from tapping point to
out let via switches (CSR Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-2, PAGE NO-4) | No | 1066.05 | 1066.05 | 8.0 | False | None | None | False | None | False | 8528.4 | 0 | 3831215 | 146006 | None | code37 | Circuit main wiring, Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010, 1.0 Sqmm Cu FRLS wire (CSR Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-2, PAGE NO-4) | Mtr | 19.57 | 19.57 | 1100.0 | False | None | None | False | None | False | 21527.0 | 0 | 3831216 | 146006 | None | code38 | Circuit main wiring, Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 Sqmm Cu FRLS wire (CSR Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-2, PAGE NO-4) | Mtr | 26.78 | 26.78 | 1100.0 | False | None | None | False | None | False | 29458.0 | 0 | 3831217 | 146006 | None | code39 | Circuit main wiring, Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010, 2.5 Sqmm Cu FRLS wire (CSR Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-2, PAGE NO-4) | Mtr | 43.26 | 43.26 | 1100.0 | False | None | None | False | None | False | 47586.0 | 0 | 3831218 | 146006 | None | code40 | Circuit main wiring, Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010, 4.0 Sqmm Cu FRLS wire (CSR Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-2, PAGE NO-4) | Mtr | 64.89 | 64.89 | 800.0 | False | None | None | False | None | False | 51912.0 | 0 | 3831219 | 146006 | None | code41 | Circuit main wiring, Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010, 6.0 Sqmm Cu FRLS wire (CSR Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-2, PAGE NO-4) | Mtr | 94.76 | 94.76 | 500.0 | False | None | None | False | None | False | 47380.0 | 0 | 3831220 | 146006 | None | code42 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 6A one way switch (CSR Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-8) | No | 105.06 | 105.06 | 25.0 | False | None | None | False | None | False | 2626.5 | 0 | 3831221 | 146006 | None | code43 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket (CSR Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-8) | No | 176.13 | 176.13 | 30.0 | False | None | None | False | None | False | 5283.9 | 0 | 3831222 | 146006 | None | code44 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module (CSR Electrical SR-2023-24, ITEM NO:3.6.4 ,CH-3, PAGE NO-8) | No | 367.71 | 367.71 | 30.0 | False | None | None | False | None | False | 11031.3 | 0 | 3831223 | 146006 | None | code45 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal socket (CSR Electrical SR-2023-24, ITEM NO:3.6.10 ,CH-3, PAGE NO-8) | No | 243.08 | 243.08 | 30.0 | False | None | None | False | None | False | 7292.4 | 0 | 3831224 | 146006 | None | code46 | Light fixture, Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hrLumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltageOverload, short circuitmisswiring protectionCompatible for pole mauling with outer dia of 40mm to 50mm Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS10322/ IEC 60598, LM 79 LM 80 Adherence with RoHS.UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site locationwith minimized minimal tools.LEDLight fixture with W System Power consumption LED Efficiency1301mw, nominal CRI75.Luminaire manufacturer should have in- house facility accredited by NABL CPRI any Government certified agency & Design & evelopmentfacility certified by ISO. Housing with supplier word markname shall be EngravedEmbossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & CreeNichia LumiledsOsram make LED Source | No | 9770.58 | 9770.58 | 40.0 | False | None | None | False | None | False | 390823.2 | 0 | 3831225 | 146006 | None | code47 | Earthing, GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 6 mm GI strip (CSR Electrical SR-2023-24, ITEM NO:12.58.3, PAGE NO-53), | Mtr | 131.84 | 131.84 | 500.0 | False | None | None | False | None | False | 65920.0 | 0 | 3831226 | 146006 | None | code48 | Earthing, 8 SWG GI Wire
(4.064 mm Dia), Std Wt: 131 Kg/KM , (SL No 61., I.No.8.02,ESCOMs SR 2023-24) | MT | 77291.2 | 77291.2 | 0.032 | False | None | None | False | None | False | 2473.3184 | 0 | 3831227 | 146006 | None | code49 | Supply & installation of Cable Trays fixed with MS angles, hitech & anchor fastner supports at interval 0.9M interval shall be included complete run below ceiling/wall.Supplying & Laying cable trays including welding, fixing of supports Cable tray of 300 mm width (suitable for cable duct of D type) (Page No.120., I.No.22 a (ii), KPTCL SCHEDULE OF RATES 2023-24) | Mtr | 776.62 | 776.62 | 150.0 | False | None | None | False | None | False | 116493.0 | 0 | 3831228 | 146006 | None | code50 | Pipe earthing, Supplying fixing and wiring earth electrode for grounding of lifts,transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrodeshould be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. CSR Electrical SR-2023-24, ITEM NO:12.57, PAGE NO-54 CH NO-12 | No | 4383.68 | 4383.68 | 4.0 | False | None | None | False | None | False | 17534.72 | 0 |
|