tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1724667638000 | 0 | None | None | Buildings | ADM Block and Repair bay | 31262926.98 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3856337 | 147464 | None | code01 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work (CSR 2023-24 Volume No.1 Page No.5 I.No. 1.4.1) In all kinds of soils Depth upto 1.5m | Cum | 284.59 | 284.59 | 998.23 | False | None | None | False | None | False | 284086.2757 | 0 | 3856338 | 147464 | None | code02 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work (CSR 2023-24 Volume No.1 Page No.5 I.No. 1.4.2) In all kinds of soils Depth exceeding 1.5m, but not exceeding 3 m | Cum | 319.09 | 319.09 | 762.37 | False | None | None | False | None | False | 243264.6433 | 0 | 3856339 | 147464 | None | code03 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size, with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications. (CSR23-24 V 1 /Page No 11/1.23 ) | Cum | 3003.84 | 3003.84 | 230.02 | False | None | None | False | None | False | 690943.2768 | 0 | 3856340 | 147464 | None | code04 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m (CSR23-24 V 1 /Page No 7/1.9 ) | Cum | 297.92 | 297.92 | 1195.43 | False | None | None | False | None | False | 356142.5056 | 0 | 3856341 | 147464 | None | code05 | Construction of Embankment by approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading,grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.(CSR23-24 V 1 /Page No 7/1.8 ) | Cum | 530.88 | 530.88 | 2750.81 | False | None | None | False | None | False | 1460350.0128 | 0 | 3856342 | 147464 | None | code06 | Providing and laying in position plain cement concrete for levellingcourse for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregate (CSR2023-24 Vol 1 page no 15/It no 2.1.2) | Cum | 6660.86 | 6660.86 | 270.82 | False | None | None | False | None | False | 1803894.1052 | 0 | 3856343 | 147464 | None | code07 | Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates SRP- 2023-24-vol 1/15/2.2.3 | Cum | 7674.67 | 7674.67 | 223.62 | False | None | None | False | None | False | 1716209.7054 | 0 | 3856344 | 147464 | None | code08 | Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates SRP- 2023-24-vol 1/15/2.2.3 | Cum | 12063.74 | 12063.74 | 25.68 | False | None | None | False | None | False | 309796.8432 | 0 | 3856345 | 147464 | None | code09 | Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates SRP- 2023-24-vol 1/15/2.2.3 | Cum | 7805.95 | 7805.95 | 83.28 | False | None | None | False | None | False | 650079.516 | 0 | 3856346 | 147464 | None | code10 | Providing and laying in Reinforced cement concrete for all Basement& surface level works, return walls, retaining walls, sunken floorsetc. The granite/trap/basalt crushed graded coarse aggregates andfine aggregates as per relevant IS Codes machine mixed with superplasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as pertechnical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP -Volume 1 / 16/2.3.2 | Cum | 10886.4 | 10886.4 | 39.97 | False | None | None | False | None | False | 435129.408 | 0 | 3856347 | 147464 | None | code11 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates. SRP- Vol 1(16/2.5.2) For Columns. | Cum | 13029.07 | 13029.07 | 28.48 | False | None | None | False | None | False | 371067.9136 | 0 | 3856348 | 147464 | None | code12 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates. SRP- Vol 1(16/2.5.2) | Cum | 12262.66 | 12262.66 | 41.24 | False | None | None | False | None | False | 505712.0984 | 0 | 3856349 | 147464 | None | code13 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates. SRP- Vol 1(16/2.5.2) | Cum | 11496.24 | 11496.24 | 4.55 | False | None | None | False | None | False | 52307.892 | 0 | 3856350 | 147464 | None | code14 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates. SRP- Vol 1(16/2.5.2) | Cum | 11496.24 | 11496.24 | 74.17 | False | None | None | False | None | False | 852676.1208 | 0 | 3856351 | 147464 | None | code15 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates. SRP- Vol 1(16/2.5.2) | Cum | 7664.16 | 7664.16 | 46.03 | False | None | None | False | None | False | 352781.2848 | 0 | 3856352 | 147464 | None | code16 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates. SRP- Vol 1(16/2.5.2) | Cum | 11113.03 | 11113.03 | 3.22 | False | None | None | False | None | False | 35783.9566 | 0 | 3856353 | 147464 | None | code17 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Vol No. 1 P.No. 18/ I. No. 2.11(a) | Kg | 100.19 | 100.19 | 51151.65 | False | None | None | False | None | False | 5124883.8135 | 0 | 3856354 | 147464 | None | code18 | Construction of un-reinforced cement concrete pavement using RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90 kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base. The superplastisiser confirming to IS 9103-1999 Reaffirmed-2008 ,Coarse aggregates and Fine aggregate confirming to IS:383-2016, transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work). Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work. (Groove cutting shall be paid seperately) (CSR2023-24/P-Vol-III (51/6.6) | Cum | 7586.88 | 7586.88 | 223.08 | False | None | None | False | None | False | 1692481.1904 | 0 | 3856355 | 147464 | None | code19 | Supplying, fitting and placing Mild steel reinforcement complete in sub structure as per drawing and technical specification (CSR 2023-24/P- Vol-I /18/2.12/a) | Kg | 82.56 | 82.56 | 9871.2 | False | None | None | False | None | False | 814966.272 | 0 | 3856356 | 147464 | None | code20 | Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm in concrete slab using concrete cutting machine with diamond studded saw within 4-8 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge. (CSR2023-24/P No 163/ It no 4/Morth 602.6.3) | Rmtr | 78.4 | 78.4 | 297.0 | False | None | None | False | None | False | 23284.8 | 0 | 3856357 | 147464 | None | code21 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.. CSR 2023-24 - Vol-2 (9/5.7) | Cum | 7565.6 | 7565.6 | 164.81 | False | None | None | False | None | False | 1246886.536 | 0 | 3856358 | 147464 | None | code22 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(CSR 2023-24 Vol 2 page no 14/It no 6.13) | Sqm | 1093.12 | 1093.12 | 40.82 | False | None | None | False | None | False | 44621.1584 | 0 | 3856359 | 147464 | None | code23 | Providing Honne wood wrought and putup for purlins, common rafter sand similar work including cost of materials, labour, usage charges complete as per specifications. SRP- Vol-2 (99/12.2) | Cum | 152622.4 | 152622.4 | 0.89 | False | None | None | False | None | False | 135833.936 | 0 | 3856360 | 147464 | None | code24 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot ressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification. (CSR 2023-24/Vol-II /106/12.57.5) 35 mm thick one side teak and one side commercial | Sqm | 4364.64 | 4364.64 | 34.56 | False | None | None | False | None | False | 150841.9584 | 0 | 3856361 | 147464 | None | code25 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. (CSR2023-24/Vol-II (105/12.54) | Rmtr | 356.16 | 356.16 | 51.0 | False | None | None | False | None | False | 18164.16 | 0 | 3856362 | 147464 | None | code26 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. (CSR2023-24/Vol-II/104/12.55.2) with one side prelam. | Sqm | 2284.8 | 2284.8 | 15.75 | False | None | None | False | None | False | 35985.6 | 0 | 3856363 | 147464 | None | code27 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(CSR2023-24 Vol II Pg87/ I No 11.35.1.2) | Kg | 547.68 | 547.68 | 170.26 | False | None | None | False | None | False | 93247.9968 | 0 | 3856364 | 147464 | None | code28 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mmX 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with touch lock Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size - 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). SRP- Vol-II (110/12.86) | Cum | 6036.8 | 6036.8 | 71.37 | False | None | None | False | None | False | 430846.416 | 0 | 3856365 | 147464 | None | code29 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge: Prelaminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications.(CSR2023-24 Vol II Pg87/ I No 11.36.1) | Sqm | 1004.64 | 1004.64 | 18.54 | False | None | None | False | None | False | 18626.0256 | 0 | 3856366 | 147464 | None | code30 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m) including cost of materials, labour, usage charges of machinery complete as per specifications.(csr2023-24-vol II P-89/11.37.1) | Sqm | 1106.56 | 1106.56 | 12.3 | False | None | None | False | None | False | 13610.688 | 0 | 3856367 | 147464 | None | code31 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing,polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (83/11.28) | Kg | 632.8 | 632.8 | 441.0 | False | None | None | False | None | False | 279064.8 | 0 | 3856368 | 147464 | None | code32 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.(Vol 2 page no 63/ item no 9.24) | Sqm | 3194.24 | 3194.24 | 238.88 | False | None | None | False | None | False | 763040.0512 | 0 | 3856369 | 147464 | None | code33 | Providing and laying Polished Glazed Vitrified tiles with thickness 10mm in floor with different sizes with water absorption less than 0.08%and conforming to IS:15622, of approved brand & manufacturer, in allcolours and shade, laid with cement based high polymer modified quickset tile adhesive (water based) conforming to IS : 15477, in average 6 mmthickness, including grouting of joints (Payment for grouting of joints tobe made separately) Size of Tile 800x800 mm SRP-SRP- Vol-2 (62/9.22.3) | Sqm | 1653.12 | 1653.12 | 187.55 | False | None | None | False | None | False | 310042.656 | 0 | 3856370 | 147464 | None | code34 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sand wiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on top sides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete. SRP - Vol.2/71/10.15.1) | Sqm | 4467.68 | 4467.68 | 54.25 | False | None | None | False | None | False | 242371.64 | 0 | 3856371 | 147464 | None | code35 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge.( Vol 2 Page no 59/item no9.2) | Sqm | 896.0 | 896.0 | 96.8 | False | None | None | False | None | False | 86732.8 | 0 | 3856372 | 147464 | None | code36 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete.. SRP- Vol-2/60/9.10) | Sqm | 1238.72 | 1238.72 | 173.45 | False | None | None | False | None | False | 214855.984 | 0 | 3856373 | 147464 | None | code37 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications..(Vol 2 Page no 65/It no 9.39) | Sqm | 1622.88 | 1622.88 | 95.58 | False | None | None | False | None | False | 155114.8704 | 0 | 3856374 | 147464 | None | code38 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.(Page No. 44 Item No. 8.16a | Sqm | 1386.56 | 1386.56 | 27.75 | False | None | None | False | None | False | 38477.04 | 0 | 3856375 | 147464 | None | code39 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Vol 2 page no 77/ item no 11.2) | Kg | 126.56 | 126.56 | 50184.0 | False | None | None | False | None | False | 6351287.04 | 0 | 3856376 | 147464 | None | code40 | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.(Vol 2 page no 85/11.34A) | Kg | 188.16 | 188.16 | 1929.69 | False | None | None | False | None | False | 363090.4704 | 0 | 3856377 | 147464 | None | code41 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(Vol 2 page no 26/ It no 7.38) | Sqm | 636.16 | 636.16 | 1146.4 | False | None | None | False | None | False | 729293.824 | 0 | 3856378 | 147464 | None | code42 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as perspecifications and as per directions of Engineer-in-charge. SRP- Vol-2/41/8.2.1 | Sqm | 330.4 | 330.4 | 695.54 | False | None | None | False | None | False | 229806.416 | 0 | 3856379 | 147464 | None | code43 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-2/ 41/8.3.1 | Sqm | 396.48 | 396.48 | 764.09 | False | None | None | False | None | False | 302946.4032 | 0 | 3856380 | 147464 | None | code44 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..(Vol 2 Page no 41/It no 8.1.1) | Sqm | 285.6 | 285.6 | 449.8 | False | None | None | False | None | False | 128462.88 | 0 | 3856381 | 147464 | None | code45 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Vol 2 Page no 50/It no 8.51) | Sqm | 112.0 | 112.0 | 1145.34 | False | None | None | False | None | False | 128278.08 | 0 | 3856382 | 147464 | None | code46 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2/ 45/8.25) | Sqm | 153.44 | 153.44 | 1145.34 | False | None | None | False | None | False | 175740.9696 | 0 | 3856383 | 147464 | None | code47 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2/46/8.30) | Sqm | 194.88 | 194.88 | 764.09 | False | None | None | False | None | False | 148905.8592 | 0 | 3856384 | 147464 | None | code48 | Providing PVC ringtite pipes conf corming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) PVC pipes 110mm dia., 6 kg (CSR2023-24/ Vol-V/113/10.1.7 ) | Rmtr | 460.32 | 460.32 | 140.8 | False | None | None | False | None | False | 64813.056 | 0 | 3856385 | 147464 | None | code49 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover (CSR2023-24-Vol 5 Page no191 / It no 16.8) | No | 5365.92 | 5365.92 | 10.0 | False | None | None | False | None | False | 53659.2 | 0 | 3856386 | 147464 | None | code50 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) PVC pipes 160mm Dai (CSR2023-24/ Vol-V/113/10.1.9 | Rmtr | 692.16 | 692.16 | 50.0 | False | None | None | False | None | False | 34608.0 | 0 | 3856387 | 147464 | None | code51 | Providing and fixing chprinated poly venyl chloride (CPVC) pipes having thermal stability for hot and cool watwr supply incl all CPVC plain brass threaded fittings incl fixing the pipe with clamp at 1.00 mtr spacing. This incl jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete (internal work exposed on wall) specification (CSR2023-24/Vol II/122/13.31.3) 25 mm dia | Rmtr | 356.16 | 356.16 | 100.0 | False | None | None | False | None | False | 35616.0 | 0 | 3856388 | 147464 | None | code52 | Providing and fixing chprinated poly venyl chloride (CPVC) pipes having thermal stability for hot and cool watwr supply incl all CPVC plain brass threaded fittings incl fixing the pipe with clamp at 1.00 mtr spacing. This incl jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete (internal work exposed on wall) specification. (CSR2023-24/ Vol II/122/13.31.2 ) 20 mm dia | Rmtr | 271.04 | 271.04 | 60.0 | False | None | None | False | None | False | 16262.4 | 0 | 3856389 | 147464 | None | code53 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required. W.C. pan with ISI marked white solid plastic seat and lid.SRP- Vol-II (131/14.3.1) | No | 6694.24 | 6694.24 | 4.0 | False | None | None | False | None | False | 26776.96 | 0 | 3856390 | 147464 | None | code54 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm withintegral type foot rests CSR 2023-24 Vol II (SRP 131/14.1.1) | No | 5470.08 | 5470.08 | 6.0 | False | None | None | False | None | False | 32820.48 | 0 | 3856391 | 147464 | None | code55 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps (CSR 2023-24 Vol 2 Page no 132/It no 14.7.1) | No | 3451.84 | 3451.84 | 4.0 | False | None | None | False | None | False | 13807.36 | 0 | 3856392 | 147464 | None | code56 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete. (CSR2023-24/Vol.2/ 127/ 13.59) | No | 246.4 | 246.4 | 6.0 | False | None | None | False | None | False | 1478.4 | 0 | 3856393 | 147464 | None | code57 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Oval Shape 450 X350 mm (Outer dimension) (CSR2023-24/Vol-II /128/14.32.2) | No | 1140.16 | 1140.16 | 4.0 | False | None | None | False | None | False | 4560.64 | 0 | 3856394 | 147464 | None | code58 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g.(Vol 2 Page no 130/ It no 14.40.1) | No | 535.36 | 535.36 | 4.0 | False | None | None | False | None | False | 2141.44 | 0 | 3856395 | 147464 | None | code59 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern (CSR2023-24/Vol II/SRP 132/14.5.1) | No | 9679.04 | 9679.04 | 4.0 | False | None | None | False | None | False | 38716.16 | 0 | 3856396 | 147464 | None | code60 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (CSR2023-24/ Vol-II /123/13.34) | Ltr | 10.08 | 10.08 | 5000.0 | False | None | None | False | None | False | 50400.0 | 0 | 3856397 | 147464 | None | code61 | Providing and fixing chprinated poly venyl chloride (CPVC) pipes having thermal stability for hot and cool watwr supply incl all CPVC plain brass threaded fittings incl fixing the pipe with clamp at 1.00 mtr spacing. This incl jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete (internal work exposed on wall) specification (CSR2023-24/Vol II/122/13.31.5 ) 40 mm dia | Rmtr | 600.32 | 600.32 | 150.0 | False | None | None | False | None | False | 90048.0 | 0 | 3856398 | 147464 | None | code62 | Providing and fixing chprinated poly venyl chloride (CPVC) pipes having thermal stability for hot and cool watwr supply incl all CPVC plain brass threaded fittings incl fixing the pipe with clamp at 1.00 mtr spacing. This incl jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete (internal work ) specification (CSR2023-24/ Vol II/122/13.31.1. 15 mm dia | Rmtr | 203.84 | 203.84 | 50.0 | False | None | None | False | None | False | 10192.0 | 0 | 3856399 | 147464 | None | code63 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore (CSR2023-24/ Vol-II /117/13.5.1) | No | 331.52 | 331.52 | 4.0 | False | None | None | False | None | False | 1326.08 | 0 | 3856400 | 147464 | None | code64 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore (CSR2023-24/ Vol-II 117/13.4.3) | No | 786.24 | 786.24 | 2.0 | False | None | None | False | None | False | 1572.48 | 0 | 3856401 | 147464 | None | code65 | Providing and fixing brass stop cock of approved quality : 15 mm nominal bore (CSR2023-24/ Vol-II /117/13.3.1) | No | 334.88 | 334.88 | 10.0 | False | None | None | False | None | False | 3348.8 | 0 | 3856402 | 147464 | None | code66 | Providing and fixing Chorinated PolyVenyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 50mm nominal OD pipes. (CSR2023-24/P122/Vol.2/13.31.6) | Rmtr | 874.72 | 874.72 | 80.0 | False | None | None | False | None | False | 69977.6 | 0 | 3856403 | 147464 | None | code67 | Laying Cement Concrete Pipe NP3 (burried conduits) of 500mm dia on first class bedding of granular material including fixing collar with cement sand mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonary work in head wall and parapets (CSR 2023-24 Vol 3 P-147 / 16.17) | Rmtr | 2903.04 | 2903.04 | 25.0 | False | None | None | False | None | False | 72576.0 | 0 | 3856404 | 147464 | None | code68 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.(CSR 2023-24/Vol 2 Page no 54 / It no 8.79) | Rmtr | 58.24 | 58.24 | 450.0 | False | None | None | False | None | False | 26208.0 | 0 |
| 1724667638000 | 0 | None | None | Buildings | Security and Traffic Building | 2014440.53 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3856405 | 147465 | None | code01 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work (CSR 2023-24 Volume No.1 Page No.5 I.No. 1.4.1) In all kinds of soils Depth upto 1.5m | Cum | 284.59 | 284.59 | 58.71 | False | None | None | False | None | False | 16708.2789 | 0 | 3856406 | 147465 | None | code02 | Construction of Embankment by approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading,grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage & all other appurtenaces required to complete the work.(CSR23-24 V 1 /Page No 7/1.8 ) | Cum | 583.97 | 583.97 | 57.49 | False | None | None | False | None | False | 33572.4353 | 0 | 3856407 | 147465 | None | code03 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size, with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications. (CSR23-24 V 1 /Page No 11/1.23 ) | Cum | 3003.84 | 3003.84 | 6.27 | False | None | None | False | None | False | 18834.0768 | 0 | 3856408 | 147465 | None | code04 | Providing and laying in position plain cement concrete for levellingcourse for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately Mix 1:4:8 ( M7.5) Using 40 mm nominal size graded crushed coarse aggregate (CSR2023-24 Vol 1 page no 15/It no 2.1.2) | Cum | 6343.68 | 6343.68 | 13.66 | False | None | None | False | None | False | 86654.6688 | 0 | 3856409 | 147465 | None | code05 | Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates SRP- 2023-24-vol 1/15/2.2.3 | Cum | 7309.21 | 7309.21 | 11.54 | False | None | None | False | None | False | 84348.2834 | 0 | 3856410 | 147465 | None | code06 | Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates SRP- 2023-24-vol 1/15/2.2.3 | Cum | 12063.74 | 12063.74 | 1.49 | False | None | None | False | None | False | 17974.9726 | 0 | 3856411 | 147465 | None | code07 | Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates SRP- 2023-24-vol 1/15/2.2.3 | Cum | 7805.95 | 7805.95 | 9.18 | False | None | None | False | None | False | 71658.621 | 0 | 3856412 | 147465 | None | code08 | Providing and laying in Reinforced cement concrete for all Basement& surface level works, return walls, retaining walls, sunken floorsetc. The granite/trap/basalt crushed graded coarse aggregates andfine aggregates as per relevant IS Codes machine mixed with superplasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as pertechnical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP -Volume 1 / 16/2.3.2 | Cum | 10886.4 | 10886.4 | 3.52 | False | None | None | False | None | False | 38320.128 | 0 | 3856413 | 147465 | None | code09 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates. SRP- Vol 1(16/2.5.2) For Columns. | Cum | 13029.07 | 13029.07 | 2.61 | False | None | None | False | None | False | 34005.8727 | 0 | 3856414 | 147465 | None | code10 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates. SRP- Vol 1(16/2.5.2) | Cum | 12262.66 | 12262.66 | 5.89 | False | None | None | False | None | False | 72227.0674 | 0 | 3856415 | 147465 | None | code11 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates. SRP- Vol 1(16/2.5.2) | Cum | 11496.24 | 11496.24 | 4.15 | False | None | None | False | None | False | 47709.396 | 0 | 3856416 | 147465 | None | code12 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates. SRP- Vol 1(16/2.5.2) | Cum | 11496.24 | 11496.24 | 7.68 | False | None | None | False | None | False | 88291.1232 | 0 | 3856417 | 147465 | None | code13 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates. SRP- Vol 1(16/2.5.2) | Cum | 11113.03 | 11113.03 | 0.6 | False | None | None | False | None | False | 6667.818 | 0 | 3856418 | 147465 | None | code14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol No. 1 P 17/2.5.2) | Cum | 7664.16 | 7664.16 | 4.75 | False | None | None | False | None | False | 36404.76 | 0 | 3856419 | 147465 | None | code15 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Vol No. 1 P.No. 18/ I. No. 2.11(a) | Kg | 100.19 | 100.19 | 4558.0 | False | None | None | False | None | False | 456666.02 | 0 | 3856420 | 147465 | None | code16 | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.(Vol 2 page no 85/11.34A) | Kg | 188.16 | 188.16 | 521.51 | False | None | None | False | None | False | 98127.3216 | 0 | 3856421 | 147465 | None | code17 | Providing Honne wood wrought and putup for purlins, common rafter sand similar work including cost of materials, labour, usage charges complete as per specifications. SRP- Vol-2 (99/12.2) | Cum | 152622.4 | 152622.4 | 0.17 | False | None | None | False | None | False | 25945.808 | 0 | 3856422 | 147465 | None | code18 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned, chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot ressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification. (CSR 2023-24/Vol-II /106/12.57.5) 35 mm thick one side teak and one side commercial | Sqm | 4364.64 | 4364.64 | 4.41 | False | None | None | False | None | False | 19248.0624 | 0 | 3856423 | 147465 | None | code19 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mmX 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with touch lock Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size - 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). SRP- Vol-II (110/12.86) | Sqm | 6036.8 | 6036.8 | 12.6 | False | None | None | False | None | False | 76063.68 | 0 | 3856424 | 147465 | None | code20 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.. CSR 2023-24 - Vol-2 (9/5.7) | Cum | 7565.6 | 7565.6 | 20.38 | False | None | None | False | None | False | 154186.928 | 0 | 3856425 | 147465 | None | code21 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as perspecifications and as per directions of Engineer-in-charge. SRP- Vol-2/41/8.2.1 | Sqm | 330.4 | 330.4 | 127.04 | False | None | None | False | None | False | 41974.016 | 0 | 3856426 | 147465 | None | code22 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-2/ 41/8.3.1 | Sqm | 396.48 | 396.48 | 200.1 | False | None | None | False | None | False | 79335.648 | 0 | 3856427 | 147465 | None | code23 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..(Vol 2 Page no 41/It no 8.1.1) | Sqm | 285.6 | 285.6 | 58.76 | False | None | None | False | None | False | 16781.856 | 0 | 3856428 | 147465 | None | code24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Vol 2 Page no 50/It no 8.51) | Sqm | 112.0 | 112.0 | 185.8 | False | None | None | False | None | False | 20809.6 | 0 | 3856429 | 147465 | None | code25 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.(Page No. 44 Item No. 8.16a | Sqm | 1386.56 | 1386.56 | 10.73 | False | None | None | False | None | False | 14877.7888 | 0 | 3856430 | 147465 | None | code26 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing,polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (85/11.28) | Kg | 632.8 | 632.8 | 183.6 | False | None | None | False | None | False | 116182.08 | 0 | 3856431 | 147465 | None | code27 | Providing and laying Polished Glazed Vitrified tiles with thickness 10mm in floor with different sizes with water absorption less than 0.08%and conforming to IS:15622, of approved brand & manufacturer, in allcolours and shade, laid with cement based high polymer modified quickset tile adhesive (water based) conforming to IS : 15477, in average 6 mmthickness, including grouting of joints (Payment for grouting of joints tobe made separately) Size of Tile 800x800 mm SRP-SRP- Vol-2 (62/9.22.3) | Sqm | 1653.12 | 1653.12 | 36.05 | False | None | None | False | None | False | 59594.976 | 0 | 3856432 | 147465 | None | code28 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.(Vol 2 page no 63/ item no 9.24) | Sqm | 3194.24 | 3194.24 | 34.12 | False | None | None | False | None | False | 108987.4688 | 0 | 3856433 | 147465 | None | code29 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2/ 45/8.25) | Sqm | 153.44 | 153.44 | 185.8 | False | None | None | False | None | False | 28509.152 | 0 | 3856434 | 147465 | None | code30 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2/46/8.30) | Sqm | 194.88 | 194.88 | 210.82 | False | None | None | False | None | False | 41084.6016 | 0 | 3856435 | 147465 | None | code31 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.(CSR 2021-22 )Vol 2 Page no 54 / It no 8.79) | Rmtr | 44.8 | 44.8 | 60.0 | False | None | None | False | None | False | 2688.0 | 0 |
| 1724667638000 | 0 | None | None | Buildings | Septic tank | 465207.98 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3856436 | 147466 | None | code01 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work (CSR 2023-24 Volume No.1 Page No.5 I.No. 1.4.1) In all kinds of soils Depth upto 1.5m | Cum | 351.62 | 351.62 | 73.88 | False | None | None | False | None | False | 25977.6856 | 0 | 3856437 | 147466 | None | code02 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work (CSR 2023-24 Volume No.1 Page No.5 I.No. 1.4.2) In all kinds of soils Depth exceeding 1.5m, but not exceeding 3 m | Cum | 548.24 | 548.24 | 34.35 | False | None | None | False | None | False | 18832.044 | 0 | 3856438 | 147466 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse
aggregates SRP vol I (15/2.1.2) | Cum | 6343.68 | 6343.68 | 6.95 | False | None | None | False | None | False | 44088.576 | 0 | 3856439 | 147466 | None | code04 | Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates SRP- 2023-24-vol 1/15/2.2.3 | Cum | 7309.21 | 7309.21 | 3.35 | False | None | None | False | None | False | 24485.8535 | 0 | 3856440 | 147466 | None | code05 | Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates SRP- 2023-24-vol 1/15/2.2.3 | Cum | 7805.95 | 7805.95 | 6.98 | False | None | None | False | None | False | 54485.531 | 0 | 3856441 | 147466 | None | code06 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Including Formwork. M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates. SRP- 2023-24-vol 1/16/2.3.2 | Cum | 10886.4 | 10886.4 | 2.96 | False | None | None | False | None | False | 32223.744 | 0 | 3856442 | 147466 | None | code07 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-2/ 41/8.3.1 | Sqm | 396.48 | 396.48 | 79.2 | False | None | None | False | None | False | 31401.216 | 0 | 3856443 | 147466 | None | code08 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) (SRP - Vol I/P-9 /Sl No 5.1.1) | Cum | 6284.32 | 6284.32 | 11.53 | False | None | None | False | None | False | 72458.2096 | 0 | 3856444 | 147466 | None | code09 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.. CSR 2023-24 - Vol-2 (9/5.7) | Cum | 7565.6 | 7565.6 | 1.45 | False | None | None | False | None | False | 10970.12 | 0 | 3856445 | 147466 | None | code10 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. SRP- Vol-I (P-18/2.11 a) | Kg | 100.19 | 100.19 | 1500.0 | False | None | None | False | None | False | 150285.0 | 0 |
| 1724667638000 | 0 | None | None | Buildings | Electrical Installation | 1355630.28 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3856446 | 147467 | None | code01 | Internal Wiring : Open Conduit System, Supplying heavy gauge PVC conduit pipe 19/20mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. Make:VIP/Avonplast/Finolex. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.1.1 | Mtr | 77.28 | 77.28 | 285.0 | False | None | None | False | None | False | 22024.8 | 0 | 3856447 | 147467 | None | code02 | Internal Wiring : Open Conduit System, Supplying heavy gauge PVC conduit pipe 19/20mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2 mm thick. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.1.2 | Mtr | 90.72 | 90.72 | 225.0 | False | None | None | False | None | False | 20412.0 | 0 | 3856448 | 147467 | None | code03 | Internal Wiring : Open Conduit System, Supplying heavy gauge PVC conduit pipe 19/20mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32mm dia 2.5 mm thick. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.1.3 | Mtr | 118.72 | 118.72 | 75.0 | False | None | None | False | None | False | 8904.0 | 0 | 3856449 | 147467 | None | code04 | Internal Wiring : Open Conduit System, Supplying heavy gauge PVC conduit pipe 19/20mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 40 mm dia 2.5 mm thick. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.1.4 | Mtr | 166.88 | 166.88 | 50.0 | False | None | None | False | None | False | 8344.0 | 0 | 3856450 | 147467 | None | code05 | Concealed Conduit System: Supplying heavy gauge PVC conduit pipe 19/20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. Make:VIP/Avonplast/Finolex. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.2.1 | Mtr | 73.92 | 73.92 | 200.0 | False | None | None | False | None | False | 14784.0 | 0 | 3856451 | 147467 | None | code06 | Concealed Conduit System: Supplying heavy gauge PVC conduit pipe 19/20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 25mm dia 2 mm thick. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.2.2 | Mtr | 87.36 | 87.36 | 300.0 | False | None | None | False | None | False | 26208.0 | 0 | 3856452 | 147467 | None | code07 | Supplying heavy gauge PVC Conduit Pipe 20mm dia mm 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. Make:VIP/Avonplast/Finolex. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.3.1 | Mtr | 76.16 | 76.16 | 150.0 | False | None | None | False | None | False | 11424.0 | 0 | 3856453 | 147467 | None | code08 | Supplying heavy gauge PVC Conduit Pipe 20mm dia mm 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25mm dia 2 mm thick. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.3.2 | Mtr | 88.48 | 88.48 | 300.0 | False | None | None | False | None | False | 26544.0 | 0 | 3856454 | 147467 | None | code09 | Supplying heavy gauge PVC Conduit Pipe 20mm dia mm 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 32mm dia 2.5 mm thick. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.3.3 | Mtr | 110.88 | 110.88 | 125.0 | False | None | None | False | None | False | 13860.0 | 0 | 3856455 | 147467 | None | code10 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm etc. as required.25mm. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 3 of 105, 47/1.8.2 | Mtr | 39.2 | 39.2 | 300.0 | False | None | None | False | None | False | 11760.0 | 0 | 3856456 | 147467 | None | code11 | Supplying PVC flexible conduit pipe 20 mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 3 of 105, 1.9.1 | Mtr | 21.28 | 21.28 | 50.0 | False | None | None | False | None | False | 1064.0 | 0 | 3856457 | 147467 | None | code12 | Supplying PVC flexible conduit pipe 20 mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 25mm. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 3 of 105, 1.9.2 | Mtr | 24.64 | 24.64 | 50.0 | False | None | None | False | None | False | 1232.0 | 0 | 3856458 | 147467 | None | code13 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Wire make:Finolex/V-Gaurd/Polycab/Anchor FRLS/Havells/KEI/Salzer. Short Point Upto 3m from tapping point to out let via switch. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.2.1 | Point | 301.28 | 301.28 | 25.0 | False | None | None | False | None | False | 7532.0 | 0 | 3856459 | 147467 | None | code14 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6 mtr from tapping point to outlet via switch box. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.2.2 | Point | 424.48 | 424.48 | 40.0 | False | None | None | False | None | False | 16979.2 | 0 | 3856460 | 147467 | None | code15 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch box. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.2.3 | Point | 621.6 | 621.6 | 70.0 | False | None | None | False | None | False | 43512.0 | 0 | 3856461 | 147467 | None | code16 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm. Wire make:Finolex/V-Gaurd /Polycab /Anchor FRLS /Havells /KEI/Salzer. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.3.2 | m | 29.12 | 29.12 | 1120.0 | False | None | None | False | None | False | 32614.4 | 0 | 3856462 | 147467 | None | code17 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 Sqmm Wire. make:Finolex/V-Gaurd /Polycab/Anchor /Havells / KEI /Salzer. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.3.3 | m | 47.04 | 47.04 | 1800.0 | False | None | None | False | None | False | 84672.0 | 0 | 3856463 | 147467 | None | code18 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 Sqmm Wire. make:Finolex/V-Gaurd /Polycab /Anchor/Havells /KEI/Salzer .
CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.3.4 | m | 70.56 | 70.56 | 1000.0 | False | None | None | False | None | False | 70560.0 | 0 | 3856464 | 147467 | None | code19 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 Sqmm Wire. make:Finolex/V-Gaurd /Polycab/Anchor /Havells /KEI/Salzer. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.3.5 | m | 103.04 | 103.04 | 100.0 | False | None | None | False | None | False | 10304.0 | 0 | 3856465 | 147467 | None | code20 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 Sqmm Wire. make:Finolex/V-Gaurd /Polycab/Anchor /Havells /KEI/Salzer .
CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.3.7 | m | 356.16 | 356.16 | 25.0 | False | None | None | False | None | False | 8904.0 | 0 | 3856466 | 147467 | None | code21 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2 way. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.4.1 | Each | 154.56 | 154.56 | 12.0 | False | None | None | False | None | False | 1854.72 | 0 | 3856467 | 147467 | None | code22 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5 Way. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.4.3 | Each | 198.24 | 198.24 | 10.0 | False | None | None | False | None | False | 1982.4 | 0 | 3856468 | 147467 | None | code23 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6 Way. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.4.4 | Each | 246.4 | 246.4 | 12.0 | False | None | None | False | None | False | 2956.8 | 0 | 3856469 | 147467 | None | code24 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 Way. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.4.5 | Each | 404.32 | 404.32 | 12.0 | False | None | None | False | None | False | 4851.84 | 0 | 3856470 | 147467 | None | code25 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12 Way. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.4.6 | Each | 357.28 | 357.28 | 14.0 | False | None | None | False | None | False | 5001.92 | 0 | 3856471 | 147467 | None | code26 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. | Each | 406.56 | 406.56 | 16.0 | False | None | None | False | None | False | 6504.96 | 0 | 3856472 | 147467 | None | code27 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 18 Way. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.4.8 | Each | 453.6 | 453.6 | 12.0 | False | None | None | False | None | False | 5443.2 | 0 | 3856473 | 147467 | None | code28 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 module. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.5.1 | Each | 153.44 | 153.44 | 20.0 | False | None | None | False | None | False | 3068.8 | 0 | 3856474 | 147467 | None | code29 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.5.3 | Each | 196.0 | 196.0 | 14.0 | False | None | None | False | None | False | 2744.0 | 0 | 3856475 | 147467 | None | code30 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.5.4 | Each | 262.08 | 262.08 | 10.0 | False | None | None | False | None | False | 2620.8 | 0 | 3856476 | 147467 | None | code31 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.5.5 | Each | 318.08 | 318.08 | 10.0 | False | None | None | False | None | False | 3180.8 | 0 | 3856477 | 147467 | None | code32 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12Module. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.5.6 | Each | 385.28 | 385.28 | 18.0 | False | None | None | False | None | False | 6935.04 | 0 | 3856478 | 147467 | None | code33 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12Module. 16 Module. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.5.7 | Each | 444.64 | 444.64 | 20.0 | False | None | None | False | None | False | 8892.8 | 0 | 3856479 | 147467 | None | code34 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12Module. 18 Module. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.5.8 | Each | 511.84 | 511.84 | 12.0 | False | None | None | False | None | False | 6142.08 | 0 | 3856480 | 147467 | None | code35 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 A One way Switch. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.6.1 | Each | 114.24 | 114.24 | 225.0 | False | None | None | False | None | False | 25704.0 | 0 | 3856481 | 147467 | None | code36 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 A Three Way Socket. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.6.3 | Each | 191.52 | 191.52 | 75.0 | False | None | None | False | None | False | 14364.0 | 0 | 3856482 | 147467 | None | code37 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 A Three Way Socket. Stepped Fan Regulator. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.6.4 | Each | 399.84 | 399.84 | 40.0 | False | None | None | False | None | False | 15993.6 | 0 | 3856483 | 147467 | None | code38 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16 A One Way Switch. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.6.7 | Each | 201.6 | 201.6 | 20.0 | False | None | None | False | None | False | 4032.0 | 0 | 3856484 | 147467 | None | code39 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32 A D.P. Switch.
Make: Anchor/GM/Cona/Salzer/Lisha.
CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.6.9 | Each | 365.12 | 365.12 | 12.0 | False | None | None | False | None | False | 4381.44 | 0 | 3856485 | 147467 | None | code40 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16 A Universal Socket. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.6.10 | Each | 264.32 | 264.32 | 30.0 | False | None | None | False | None | False | 7929.6 | 0 | 3856486 | 147467 | None | code41 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. R J 45/I.O.Out let Cat-6 Make: Anchor/GM/Cona/Salzer/Lisha.
CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.6.12 | Each | 377.44 | 377.44 | 25.0 | False | None | None | False | None | False | 9436.0 | 0 | 3856487 | 147467 | None | code42 | Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size 110 mm conduit using necessary machine screws. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.10.3 | Each | 23.52 | 23.52 | 45.0 | False | None | None | False | None | False | 1058.4 | 0 | 3856488 | 147467 | None | code43 | Supplying And fixing of 6 A electrical accessories on existing switch board. 6 A Ceilling Rose. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 10 of 105, 3.14.5 | Each | 87.36 | 87.36 | 36.0 | False | None | None | False | None | False | 3144.96 | 0 | 3856489 | 147467 | None | code44 | Supplying And fixing of 6 A electrical accessories on existing switch board. 6 A Batten Holder. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 10 of 105, 3.14.7 | Each | 82.88 | 82.88 | 75.0 | False | None | None | False | None | False | 6216.0 | 0 | 3856490 | 147467 | None | code45 | Control Switch Gears & Accessories: Fabricating supplying and mounting MS box made out 16 SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 20 of 105, 5.42.2 | Sq CM | 0.43 | 0.43 | 300000.0 | False | None | None | False | None | False | 129000.0 | 0 | 3856491 | 147467 | None | code46 | Supplying 100 A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100 Amps 4X30X6mm Aluminium Strips.
CSR 2023-24, Volume-6, Part-III,Utilization, SRP 20 of 105, 5.40.1 | m | 2479.68 | 2479.68 | 6.0 | False | None | None | False | None | False | 14878.08 | 0 | 3856492 | 147467 | None | code47 | Supplying 100 A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250 A 4 X 30 X 10mm Aluminium Strips.
CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 20 of 105, 5.40.2 | m | 3447.36 | 3447.36 | 2.0 | False | None | None | False | None | False | 6894.72 | 0 | 3856493 | 147467 | None | code48 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40 X 40 X 6mm . CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 20 of 105, 5.41.1 | m | 308.0 | 308.0 | 25.0 | False | None | None | False | None | False | 7700.0 | 0 | 3856494 | 147467 | None | code49 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 X 75 X 6 mm angle iron frame work. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 20 of 105, 5.41.3 | m | 556.64 | 556.64 | 8.0 | False | None | None | False | None | False | 4453.12 | 0 | 3856495 | 147467 | None | code50 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 19 of 105, 5.38 | Each | 519.68 | 519.68 | 16.0 | False | None | None | False | None | False | 8314.88 | 0 | 3856496 | 147467 | None | code51 | Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 19 of 105, 5.34 | Each | 565.6 | 565.6 | 12.0 | False | None | None | False | None | False | 6787.2 | 0 | 3856497 | 147467 | None | code52 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 19 of 105, 5.33 | Each | 9374.4 | 9374.4 | 3.0 | False | None | None | False | None | False | 28123.2 | 0 | 3856498 | 147467 | None | code53 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 18 of 105, 5.21 | Each | 9313.92 | 9313.92 | 1.0 | False | None | None | False | None | False | 9313.92 | 0 | 3856499 | 147467 | None | code54 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100 Amps 25kA.Four Pole. Make: L&T/Sneider /Legrand/Havlls. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 17 of 105, 5.15.9 | Each | 9256.8 | 9256.8 | 6.0 | False | None | None | False | None | False | 55540.8 | 0 | 3856500 | 147467 | None | code55 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 125 A 25kA Four Pole MCCB. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 17 of 105, 5.15.10 | Each | 11280.64 | 11280.64 | 2.0 | False | None | None | False | None | False | 22561.28 | 0 | 3856501 | 147467 | None | code56 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6 - 32 Amps.SP. Make: L&T/Sneider/Legrand/ Havells. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 17 of 105, 5.18.1 | Each | 585.76 | 585.76 | 30.0 | False | None | None | False | None | False | 17572.8 | 0 | 3856502 | 147467 | None | code57 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP MCB. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 17 of 105, 5.18.4 | Each | 1235.36 | 1235.36 | 25.0 | False | None | None | False | None | False | 30884.0 | 0 | 3856503 | 147467 | None | code58 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps TPN MCB. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 17 of 105, 5.18.7 | Each | 1990.24 | 1990.24 | 12.0 | False | None | None | False | None | False | 23882.88 | 0 | 3856504 | 147467 | None | code59 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 Amps TPN MCB. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 17 of 105, 5.18.8 | Each | 2680.16 | 2680.16 | 12.0 | False | None | None | False | None | False | 32161.92 | 0 | 3856505 | 147467 | None | code60 | L.T.Underground Cables: 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 10SQmm 4 Core. (10 GI Stris-4 X 0.8 mm). Make: Finolex/ Polycab/Havells/KEI. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 13 of 81, 199/32.03. | Km | 166445.44 | 166445.44 | 0.1 | False | None | None | False | None | False | 16644.544 | 0 | 3856506 | 147467 | None | code61 | L.T.Underground Cables: 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.16 SQmm, 4 Core LTUG Cable , (11 GI Strips- 4x 0.8mm) CSR 2023-24, Volume-6, Part-III ,Utilization,
SRP 13 of 81, 201/32.05. | Km | 205455.04 | 205455.04 | 0.15 | False | None | None | False | None | False | 30818.256 | 0 | 3856507 | 147467 | None | code62 | L.T.Underground Cables: 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 25 SQmm, 4 Core LTUG Cable , (13 GI Strips- 4x 0.8mm) CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 13 of 81, 204/32.08. | Km | 269710.56 | 269710.56 | 0.15 | False | None | None | False | None | False | 40456.584 | 0 | 3856508 | 147467 | None | code63 | L.T.Underground Cables: 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 50 SQmm, 4 Core LTUG Cable, 17 GI Strips- 4x 0.8mm) CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 13 of 81, 208/32.12. | Km | 232057.28 | 232057.28 | 0.2 | False | None | None | False | None | False | 46411.456 | 0 | 3856509 | 147467 | None | code64 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. Water Supply & UGD Works CSR 2021-22, Volume-V. SRP 163/40. | Each | 4977.0 | 4977.0 | 4.0 | False | None | None | False | None | False | 19908.0 | 0 | 3856510 | 147467 | None | code65 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, . In Hard Soil. CSR 2021-22,Volume-VI, SRP 8 of 14/ 202-29.03. | cm | 389.0 | 389.0 | 40.0 | False | None | None | False | None | False | 15560.0 | 0 | 3856511 | 147467 | None | code66 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. LT Cable: 2.5 to 25 SQmm. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 52 of 81, 174/21.05. | Km | 18098.08 | 18098.08 | 0.75 | False | None | None | False | None | False | 13573.56 | 0 | 3856512 | 147467 | None | code67 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 35 to 95 SQMM .
CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 52 of 81, 175/21.06. | Km | 26484.64 | 26484.64 | 1.0 | False | None | None | False | None | False | 26484.64 | 0 | 3856513 | 147467 | None | code68 | Aluminium End Terminal (Lug)- 10 SQmm size. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 27 of 81, 469/60.01. | No | 3.36 | 3.36 | 64.0 | False | None | None | False | None | False | 215.04 | 0 | 3856514 | 147467 | None | code69 | Aluminium End Terminal (Lug)- 16 SQmm size. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 27 of 81, 470/60.02. | No | 3.36 | 3.36 | 36.0 | False | None | None | False | None | False | 120.96 | 0 | 3856515 | 147467 | None | code70 | Aluminium End Terminal (Lug)- 25 SQmm size. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 27 of 81, 471/60.03. | No | 4.48 | 4.48 | 36.0 | False | None | None | False | None | False | 161.28 | 0 | 3856516 | 147467 | None | code71 | Aluminium End Terminal (Lug)-50 SQmm size. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 27 of 81, 473/60.05. | No | 10.08 | 10.08 | 36.0 | False | None | None | False | None | False | 362.88 | 0 | 3856517 | 147467 | None | code72 | PVC Pipe as per IS-2509-100 mm dia.
CSR 2021-22,Volume-VI, SRP 15 of 27/392-48.09 | Mtr | 256.0 | 256.0 | 35.0 | False | None | None | False | None | False | 8960.0 | 0 | 3856518 | 147467 | None | code73 | PVC Pipe as per IS-2509-150 mm dia.
CSR 2021-22,Volume-VI, SRP 15 of 27/393-48.10 | Mtr | 534.0 | 534.0 | 50.0 | False | None | None | False | None | False | 26700.0 | 0 | 3856519 | 147467 | None | code74 | Digging of Pit for providing GI Pipe type Earthing. Hard Soil. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 43 of 81, 22 / 1.6.2 | Per Pit | 2539.04 | 2539.04 | 8.0 | False | None | None | False | None | False | 20312.32 | 0 | 3856520 | 147467 | None | code75 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 22 of 81, 389/ 51.01 | No | 862.4 | 862.4 | 10.0 | False | None | None | False | None | False | 8624.0 | 0 | 3856521 | 147467 | None | code76 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each.
CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 22 of 81, 390 / 51.02 | No | 739.2 | 739.2 | 10.0 | False | None | None | False | None | False | 7392.0 | 0 | 3856522 | 147467 | None | code77 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 22 of 81, 391 / 51.03 | Bag | 402.08 | 402.08 | 10.0 | False | None | None | False | None | False | 4020.8 | 0 | 3856523 | 147467 | None | code78 | GI Pipe B - Class as per IS-1239-G I Pipe 40mm Dia. CSR 2021-22,Volume-VI, SRP 16 of 27/409 -49.04 | Mtr | 295.0 | 295.0 | 20.0 | False | None | None | False | None | False | 5900.0 | 0 | 3856524 | 147467 | None | code79 | GI Pipe B - Class as per IS-1239-G I Pipe 63 mm Dia. CSR 2021-22,Volume-VI, SRP 16 of 27/411 -49.06 | Mtr | 415.0 | 415.0 | 20.0 | False | None | None | False | None | False | 8300.0 | 0 | 3856525 | 147467 | None | code80 | RCC Hume pipe 2000mm long 200mm dia. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 32 of 81, 578 / 68.02 | Mtr | 1293.6 | 1293.6 | 10.0 | False | None | None | False | None | False | 12936.0 | 0 | 3856526 | 147467 | None | code81 | Collars for RCC Hume pipe 200mm dia.
CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 32 of 81, 580 / 68.04 | No | 115.36 | 115.36 | 20.0 | False | None | None | False | None | False | 2307.2 | 0 | 3856527 | 147467 | None | code82 | Supplying and drawing UTP-CAT 6E LAN cable. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 36 of 105, 580 / 8.1 | m | 42.56 | 42.56 | 300.0 | False | None | None | False | None | False | 12768.0 | 0 | 3856528 | 147467 | None | code83 | Supplying & Fixing of switch mounting rack with power manager & Cable manager.12 U with 450mm depth. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 36 of 105, 8.4.4 | Each | 9895.2 | 9895.2 | 1.0 | False | None | None | False | None | False | 9895.2 | 0 | 3856529 | 147467 | None | code84 | Supplying fixing of Network Switches: 24 Port 10/100 Switch. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 36 of 105, 8.9.5 | Each | 5264.0 | 5264.0 | 1.0 | False | None | None | False | None | False | 5264.0 | 0 | 3856530 | 147467 | None | code85 | Supplying & fixing of I/O socket with back box.Single I/O. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 36 of 105, 8.10.1 | Each | 548.8 | 548.8 | 24.0 | False | None | None | False | None | False | 13171.2 | 0 | 3856531 | 147467 | None | code86 | Supplying & fixing of First Aid Chart with Lamination. PWD ELE SR 2010-11. SRP 65/11 | Each | 225.0 | 225.0 | 2.0 | False | None | None | False | None | False | 450.0 | 0 | 3856532 | 147467 | None | code87 | Supplying & fixing of DANGER BOARD made out of MS sheet metal with two coats of non corrossive enamel paint. PWD ELE SR 2010-11. SRP 66/12 | Each | 75.0 | 75.0 | 6.0 | False | None | None | False | None | False | 450.0 | 0 | 3856533 | 147467 | None | code88 | Supplying & Installation of RUBBER MAT 1mt X 2mt-10mm thick. PWD ELE SR SRP 66/13. | Each | 1105.0 | 1105.0 | 3.0 | False | None | None | False | None | False | 3315.0 | 0 |
|
|
---|