1724666966000 | 0 | None | None | Buildings | Construction of food courts in Malur TMC limit | 416072.79 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3856287 | 147457 | None | code1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m [PWD SR 2023-24 Vol:1 P.NO.8 I.No:1.14.1] | Cum | 106.06 | 106.06 | 1.76 | False | None | None | False | None | False | 186.6656 | 0 | 3856288 | 147457 | None | code2 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.PWD SR 2023-24 Vol:3 P.NO.24 I.No: 4.18 | Cum | 2635.77 | 2635.77 | 1.32 | False | None | None | False | None | False | 3479.2164 | 0 | 3856289 | 147457 | None | code3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates(PWD SR 2023-24 Vol:3 P.NO.15 I.No:2.1.6) | Cum | 6430.29 | 6430.29 | 0.88 | False | None | None | False | None | False | 5658.6552 | 0 | 3856290 | 147457 | None | code4 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge.[PWD SR 2023-24 Vol:2 P.NO.77 I.No: 11.2] | Kg | 116.39 | 116.39 | 840.0 | False | None | None | False | None | False | 97767.6 | 0 | 3856291 | 147457 | None | code5 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and s.[PWD SR 2023-24 Vol:2 P.NO.77 I.No: 11.2]0.63 mm thick with zinc coating not less than 275 g/ m² | Sqm | 905.37 | 905.37 | 74.8 | False | None | None | False | None | False | 67721.676 | 0 | 3856292 | 147457 | None | code6 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(vol-2 2023-24 SR RATE Pg no:113,It no: 11.28) | Kg | 581.95 | 581.95 | 400.0 | False | None | None | False | None | False | 232780.0 | 0 | 3856293 | 147457 | None | code7 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing)etc,complete for: (BWSSB 2023-24 SR RATE Pg no:113,It no: 10.1.6) PVC pipes 90mm dia., 6 kg/sqcm & class 3 | Mtr | 302.82 | 302.82 | 28.0 | False | None | None | False | None | False | 8478.96 | 0 |
|