1723794433000 | 1 | None | None | Other Works | Construction of Partition and grill work to DWCC in land fill site and supplying and installation of pump motor and other accessories borwell at Landfill site. | 2114389.37 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3787783 | 143125 | None | code01 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge in charge of Work For 25 Hp (KUWSSDB SR 2023-24, V-05, Pg No:-153, Item Code:- 13.21.5)25.00 HP - 135 LPM @ 420 m = 30 STG Outlet Dia - 2.00 | Each | 85097.57 | 85097.57 | 1.0 | False | None | None | False | None | False | 85097.57 | 0 | 3787784 | 143125 | None | code02 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete.(KUWSSDB SR 2023-24, V-05, Pg No:-128, Item Code:- 11.3.6)Heavy Duty GI pipe of 50mm dia | Mtr | 699.37 | 699.37 | 400.0 | False | None | None | False | None | False | 279748.0 | 0 | 3787785 | 143125 | None | code03 | Supplying and drawing 3 core flat PVC sheathed submersible pumpcable manufactured with electrolytic grade copper with flexible copperwith low resistance conductor confirming to13:8130-1984 and virgingrade PVC insulation and powder coating extruded PVC sheathedsuitable for working voltage upto 1100 Volts as per IS-694:1990.(BESCOM SR 2023-24, V-06,Pg No:02, Item No:-2.6.3)3C x 6 mm2 | Mtr | 252.35 | 252.35 | 850.0 | False | None | None | False | None | False | 214497.5 | 0 | 3787786 | 143125 | None | code04 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975(BESCOM SR 2023-24, V-06,Pg No:13, Item No:-32.08)25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm) | Km | 185239.32 | 185239.32 | 0.01 | False | None | None | False | None | False | 1852.3932 | 0 | 3787787 | 143125 | None | code05 | Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments if any(KUWSDB SR 2023-24, V-5,Pg No:129, Item No:-11.6.6) For 50 mm dia GI collar: | Each | 275.01 | 275.01 | 70.0 | False | None | None | False | None | False | 19250.7 | 0 | 3787788 | 143125 | None | code06 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.(KUWSDB SR 2023-24, V-5,Pg No:155, Item No:-13.24.3) 6 to 15 HP pumps | Each | 18025.0 | 18025.0 | 1.0 | False | None | None | False | None | False | 18025.0 | 0 | 3787789 | 143125 | None | code07 | Supplying & fixing of Porcelain fuse channel with cut out onexisting wooden/panel using necessary nuts, bolts and washers(PWD ELE SR 2023-24, V-6,Pg No:02, Item No:-5.7.4) 100 A | Each | 711.73 | 711.73 | 3.0 | False | None | None | False | None | False | 2135.19 | 0 | 3787790 | 143125 | None | code08 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.(KUWSSDB SR 2023-24, V-6,Pg No:154, Item No:-13.32) | Job | 6695.0 | 6695.0 | 1.0 | False | None | None | False | None | False | 6695.0 | 0 | 3787791 | 143125 | None | code09 | Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for:(KUWSSDB SR 2023-24, V-6,Pg No:129, Item No:-11.7.6) For 50 mm dia GI elbow | Each | 275.01 | 275.01 | 3.0 | False | None | None | False | None | False | 825.03 | 0 | 3787792 | 143125 | None | code10 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments(KUWSSDB SR 2023-24, V-6,Pg No:154, Item No:-13.25.1) For 50 mm | Each | 1287.5 | 1287.5 | 1.0 | False | None | None | False | None | False | 1287.5 | 0 | 3787793 | 143125 | None | code11 | Supply and delivery at site of brand new best Gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments (KUWSDB SR 2023-24, V-5, Pg No:-154, Item Code:-13.24.1 ) For 50 mm | Each | 1287.5 | 1287.5 | 1.0 | False | None | None | False | None | False | 1287.5 | 0 | 3787794 | 143125 | None | code12 | Fabricating supplying and mounting MS box made out ....SWGsuitable for floor /wall mounting, fully weather proof with provisionfor better heat dissipation, provided with hinged front cover,equipped with tamper proof locking arrangements, with suitablesize clamps with necessary cable entry pipe with gland and boxshould be finished with 7tanks treatment with powder coated paintand finally finished with approved colour etc., complete.(PWD ELE SR 2023-24, V-6, Pg No:02, Code:5.42.2)16 SWG | Sq CM | 0.44 | 0.44 | 12500.0 | False | None | None | False | None | False | 5500.0 | 0 | 3787795 | 143125 | None | code13 | Wiring for lighting/power circuit using one of FRLS PVC insulated1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS 694:2010 (PWD ELE SR 2023-24, V-6,Pg No:06, Item No:-2.3.7) 16 mm2 | Mtr | 327.54 | 327.54 | 12.0 | False | None | None | False | None | False | 3930.48 | 0 | 3787796 | 143125 | None | code14 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. (PWD SR 2023-24, V-01, Pg No:-10, Item Code:-1.17.1) | Cum | 269.86 | 269.86 | 90.0 | False | None | None | False | None | False | 24287.4 | 0 | 3787797 | 143125 | None | code15 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinationsand rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0(KUWSSDB SR 2023-24, V-05, Pg No:-95, Item Code:-9.3.1)HDPE Grade PE80-PN10.0,63mm dia | Mtr | 259.56 | 259.56 | 200.0 | False | None | None | False | None | False | 51912.0 | 0 | 3787798 | 143125 | None | code16 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications(PWD SR SR 2023-24, V-01, Pg No:-07, Item Code:-1.10) | Cum | 164.8 | 164.8 | 90.0 | False | None | None | False | None | False | 14832.0 | 0 | 3787799 | 143125 | None | code17 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.(PWD SR SR 2023-24, V-02, Pg No:-86, Item Code:-11.34B)For 460 Sqm :- 10 mm Thickness (0.80 Kg per Meter ) :- 0.8*12 mtr= 9.60 Kg / Mtr. | Kg | 188.49 | 188.49 | 4416.0 | False | None | None | False | None | False | 832371.84 | 0 | 3787800 | 143125 | None | code18 | RCC Pole - 9 Mtr Long, 145 Kg WL(Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785(PWD ELE SR 2023-24, V-06, Pg No:-03, Item Code:-1.01) | No | 7288.28 | 7288.28 | 1.0 | False | None | None | False | None | False | 7288.28 | 0 | 3787801 | 143125 | None | code19 | Labour Charges for RCC Pole - 9 Mtr Long, 145 Kg WL(Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785(PWD ELE SR 2023-24, V-06, Pg No:-03, Item Code:-1.01) | No | 1381.23 | 1381.23 | 1.0 | False | None | None | False | None | False | 1381.23 | 0 | 3787802 | 143125 | None | code20 | PSCC Pole - 9 Mtr Long, 200 Kg WL (Dwg No. BESCOM/GM/QS&S/50 Dtd 24.11.2018) as per REC Standards(PWD ELE SR 2023-24, V-06, Pg No:-03, Item Code:-1.06) | No | 4324.97 | 4324.97 | 16.0 | False | None | None | False | None | False | 69199.52 | 0 | 3787803 | 143125 | None | code21 | Labour Charges for PSCC Pole - 9 Mtr Long, 200 Kg WL (Dwg No. BESCOM/GM/QS&S/50 Dtd 24.11.2018) as per REC Standards(PWD ELE SR 2023-24, V-06, Pg No:-03, Item Code:-1.06) | No | 1381.23 | 1381.23 | 16.0 | False | None | None | False | None | False | 22099.68 | 0 | 3787804 | 143125 | None | code22 | Horizontal X arms for Complete (PWD ELE SR 2023-24, V-06, Pg No:-69, Item Code:-6.03) | No | 890.95 | 890.95 | 21.0 | False | None | None | False | None | False | 18709.95 | 0 | 3787805 | 143125 | None | code23 | Fixing of V-Shape/Horizontal cross arm including Single Top Support Brace and Insulator fixing (PWD ELE SR 2023-24, V-06, Pg No:-45, Item Code:-5.03) | No | 125.66 | 125.66 | 21.0 | False | None | None | False | None | False | 2638.86 | 0 | 3787806 | 143125 | None | code24 | 4 Pin X- Arms Complete (PWD ELE SR 2023-24, V-06, Pg No:-04, Item Code:-2.06) | No | 452.17 | 452.17 | 1.0 | False | None | None | False | None | False | 452.17 | 0 | 3787807 | 143125 | None | code25 | Fixing of 4 Pin cross arm with Insulator and Braces fixing(PWD ELE SR 2023-24, V-06, Pg No:-45, Item Code:-5.02) | No | 125.66 | 125.66 | 1.0 | False | None | None | False | None | False | 125.66 | 0 | 3787808 | 143125 | None | code26 | 11KV Composite Pin Insulators with Insulator and Braces fixing(PWD ELE SR 2023-24, V-06, Pg No:-45, Item Code:-5.02) | No | 227.63 | 227.63 | 42.0 | False | None | None | False | None | False | 9560.46 | 0 | 3787809 | 143125 | None | code27 | DISC Insulator 45 kN Porcelain(PWD ELE SR 2023-24, V-06, Pg No:-05, Item Code:-6.09) | No | 208.06 | 208.06 | 24.0 | False | None | None | False | None | False | 4993.44 | 0 | 3787810 | 143125 | None | code28 | Guy Set Complete (PWD ELE SR 2023-24, V-06, Pg No:-06, Item Code:-4.08) | Set | 1245.27 | 1245.27 | 6.0 | False | None | None | False | None | False | 7471.62 | 0 | 3787811 | 143125 | None | code29 | Labour Charges for Guy Set Complete (PWD ELE SR 2023-24, V-06, Pg No:-09, Item Code:-6.09) | Set | 461.44 | 461.44 | 6.0 | False | None | None | False | None | False | 2768.64 | 0 | 3787812 | 143125 | None | code30 | Rabbit ACSR(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM (PWD ELE SR 2023-24, V-06, Pg No:-05, Item Code:-7.02) | Km | 37591.91 | 37591.91 | 1.62 | False | None | None | False | None | False | 60898.8942 | 0 | 3787813 | 143125 | None | code31 | Labour Charges for Rabbit ACSR(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM (PWD ELE SR 2023-24, V-06, Pg No:-10, Item Code:-10.08) | Km | 2955.07 | 2955.07 | 1.62 | False | None | None | False | None | False | 4787.2134 | 0 | 3787814 | 143125 | None | code32 | Alkathine tube ( Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr (PWD ELE SR 2023-24, V-06, Pg No:-23, Item Code:-52.01) | Coil | 519.12 | 519.12 | 1.0 | False | None | None | False | None | False | 519.12 | 0 | 3787815 | 143125 | None | code33 | HT AB Cable (PWD ELE SR 2023-24, V-06, Pg No:-26, Item Code:-62.09) | Mtr | 1102638.69 | 1102638.69 | 0.025 | False | None | None | False | None | False | 27565.96725 | 0 | 3787816 | 143125 | None | code34 | Labour Charges For HT AB Cable (PWD ELE SR 2023-24, V-06, Pg No:-44, Item Code:-82.06) | Mtr | 26614.17 | 26614.17 | 0.025 | False | None | None | False | None | False | 665.35425 | 0 | 3787817 | 143125 | None | code35 | Erection of 3 Phase ,11 KV/433V, 100KVA DTC Using 9 Mtrs long RCC /PSCC Pole DPTC Pole Structure CDS No 26, 4 Star Rated. | Set | 294269.97 | 294269.97 | 1.0 | False | None | None | False | None | False | 294269.97 | 0 | 3787818 | 143125 | None | code36 | Labour For Erection of 100 KVA Trsansformer | Set | 15458.24 | 15458.24 | 1.0 | False | None | None | False | None | False | 15458.24 | 0 |
|