1723098838000 | 0 | None | None | Buildings | 1Construction of Toilet for Urdu School in Ward No. 07 CMC limit Bhadravathi Rs.5.00 Lakhs 2) Construction of Public Toilet at Karumariyamma Temple in Ward No. 11 CMC limit Bhadravathi Rs 8.00 Lakhs. | 1099163.52 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3720727 | 137833 | None | Code01 | Demolishing R.C.C. work manually/ by mechanical means including stack- ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. 2023-24 Common SR,Vol.II P.No 189 . Item No 19.3 | Sqm | 2498.78 | 2498.78 | 4.2993 | False | None | None | False | None | False | 10743.004854 | 0 | 3720728 | 137833 | None | Code02 | Demolishing brick work manually/ by mechanical means including stack- ing of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar 2023-24 Common SR,Vol.II P.No 187 . Item No 19.7.3 | Cum | 1059.87 | 1059.87 | 21.5142 | False | None | None | False | None | False | 22802.255154 | 0 | 3720729 | 137833 | None | Code03 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth 2023-24 Common SR,Vol.I P.No 8 item no 1.12 | Sqm | 97.85 | 97.85 | 6.375 | False | None | None | False | None | False | 623.79375 | 0 | 3720730 | 137833 | None | Code04 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. 2023-24 Common SR,Vol.I P.No 5 i.No 1.4.1 | Cum | 249.26 | 249.26 | 31.9537 | False | None | None | False | None | False | 7964.779262 | 0 | 3720731 | 137833 | None | Code05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately)including formworkMix 1:4:8( M 7.5) Using 40 mm nominal size graded crushed coarse aggregates 2023-24 Common SR,Vol.I P.No 15 i no 2.1.2 | Cum | 5833.92 | 5833.92 | 5.5886 | False | None | None | False | None | False | 32603.445312 | 0 | 3720732 | 137833 | None | Code06 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) stone hammerd dressed in course not less than 20 cms high, bond stone at two m, apart in each course including cost of materials, labour, curing complete as per specifications. 2023-24 Common SR,Vol.II P.No 9 I no 5.4 | Cum | 6580.67 | 6580.67 | 16.0026 | False | None | None | False | None | False | 105307.829742 | 0 | 3720733 | 137833 | None | Code07 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) stone hammerd dressed in course not less than 20 cms high, bond stone at two m, apart in each course including cost of materials, labour, curing complete as per specifications. 2023-24 Common SR,Vol.II P.No 9 I no 5.4 | Cum | 6580.67 | 6580.67 | 7.1806 | False | None | None | False | None | False | 47253.159002 | 0 | 3720734 | 137833 | None | Code08 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) including formwork M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates 2023-24 Common SR,Vol.I P.No 16 I no 2.3.1 | Cum | 6838.32 | 6838.32 | 3.5903 | False | None | None | False | None | False | 24551.620296 | 0 | 3720735 | 137833 | None | Code09 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Common SR,Vol.II P.No 14 i no 6.8 | Cum | 8208.07 | 8208.07 | 16.1408 | False | None | None | False | None | False | 132484.816256 | 0 | 3720736 | 137833 | None | Code10 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.. Common SR,Vol.II P.No 14 i no 6.14 | Sqm | 1091.8 | 1091.8 | 13.1109 | False | None | None | False | None | False | 14314.48062 | 0 | 3720737 | 137833 | None | Code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) including formwork M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for BEams and lintles and Roof of Building Common SR,Vol.I P.No 16 I NO.2.5.1 | Cum | 10243.35 | 10243.35 | 11.0686 | False | None | None | False | None | False | 113379.54381 | 0 | 3720738 | 137833 | None | Code12 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.2023-24 Common SR,Vol.I P.No 18 I.no 2.11 a Buildings | Tonne | 92140.71 | 92140.71 | 1.0096 | False | None | None | False | None | False | 93025.260816 | 0 | 3720739 | 137833 | None | Code13 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Common SR,Vol.II P.No 41 i.no 8.3.2 | Sqm | 342.99 | 342.99 | 279.524 | False | None | None | False | None | False | 95873.93676 | 0 | 3720740 | 137833 | None | Code14 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Common SR,Vol.II P.No 41 i no 8.1.2 | Sqm | 248.23 | 248.23 | 60.4572 | False | None | None | False | None | False | 15007.290756 | 0 | 3720741 | 137833 | None | Code15 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Common SR,Vol.II P.No 60 i no 9.11 | Sqm | 915.67 | 915.67 | 34.7275 | False | None | None | False | None | False | 31798.929925 | 0 | 3720742 | 137833 | None | Code16 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.2023-24 Common SR,Vol.II P.No 65 i no 9.38 | Sqm | 1433.76 | 1433.76 | 54.6209 | False | None | None | False | None | False | 78313.261584 | 0 | 3720743 | 137833 | None | Code17 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame 2023-24Common SR,Vol.II P.No 112 i.no 12.96 | Mtr | 662.29 | 662.29 | 54.0 | False | None | None | False | None | False | 35763.66 | 0 | 3720744 | 137833 | None | Code18 | Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. .Common SR,Vol.II P.No 112 i.no 12.97.1 30mm thick shutter | Sqm | 3300.12 | 3300.12 | 12.6 | False | None | None | False | None | False | 41581.512 | 0 | 3720745 | 137833 | None | Code19 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Common SR,Vol.II P.No 77 i.no 11.11.1 | Kg | 152.44 | 152.44 | 38.2725 | False | None | None | False | None | False | 5834.2599 | 0 | 3720746 | 137833 | None | Code20 | Providing and fixing plain rolled glass 3mm thick with teakwood beading of 10mm thick.
Common SR,Vol.II P.No 183 I no 20.106 | Sqm | 1114.46 | 1114.46 | 1.8225 | False | None | None | False | None | False | 2031.10335 | 0 | 3720747 | 137833 | None | Code21 | Providing & fixing White vitreous china water closet squatting panOrissa pattern W.C Pan of size 580x440 mm along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.Common SR,Vol.II P.No 178 i no 20.44.2 | Pan | 3653.41 | 3653.41 | 6.0 | False | None | None | False | None | False | 21920.46 | 0 | 3720748 | 137833 | None | Code22 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.Common SR,Vol.II P.No 135 i no 14.23 | Each | 1188.62 | 1188.62 | 8.0 | False | None | None | False | None | False | 9508.96 | 0 | 3720749 | 137833 | None | Code23 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete. Common SR,Vol.II P.No 71 i no 10.18 | Sqm | 3459.77 | 3459.77 | 5.0399 | False | None | None | False | None | False | 17436.894823 | 0 | 3720750 | 137833 | None | Code24 | Constructing brick masonry chamber of internal dimension 450x300mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk etc and including concrete cover. BWSSB SR Vol. V 2023-24 p.no 191 item no 16.11 | Each | 3655.47 | 3655.47 | 2.0 | False | None | None | False | None | False | 7310.94 | 0 | 3720751 | 137833 | None | Code25 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.4kg/cm2 110mm(weight of pipe -1.315 kg) BWSSB SR vol V 2023-24 p.no 120 I No 10.14.4 | Mtr | 290.46 | 290.46 | 20.0 | False | None | None | False | None | False | 5809.2 | 0 | 3720752 | 137833 | None | Code26 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 20 mm nominal dia Pipes Common SR,Vol.II P.No 122 i.no 13.31.2 | Mtr | 249.26 | 249.26 | 31.0 | False | None | None | False | None | False | 7727.06 | 0 | 3720753 | 137833 | None | Code27 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes Common SR,Vol.II P.No 122 i.no 13.31.3 | Mtr | 327.54 | 327.54 | 25.5 | False | None | None | False | None | False | 8352.27 | 0 | 3720754 | 137833 | None | Code28 | Providing and fixing brass bib cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification Common SR,Vol.II P.No 117 item no13.2.2 | Each | 314.15 | 314.15 | 14.0 | False | None | None | False | None | False | 4398.1 | 0 | 3720755 | 137833 | None | Code29 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.75mm ( weight of pipe -0.651 kg)BWSSB SR VOL V 2023-24 p.no 131 i no 10.14.2 | Mtr | 165.83 | 165.83 | 8.0 | False | None | None | False | None | False | 1326.64 | 0 | 3720756 | 137833 | None | Code30 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Common SR,Vol.I P.No 7 I.no 1.9 | Cum | 273.98 | 273.98 | 5.8915 | False | None | None | False | None | False | 1614.15317 | 0 | 3720757 | 137833 | None | Code31 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. Common SR,Vol.II P.No 44 I .no 8.19.1 | Sqm | 262.65 | 262.65 | 10.992 | False | None | None | False | None | False | 2887.0488 | 0 | 3720758 | 137833 | None | Code32 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Common SR,Vol.II P.No 45 i no 8.25 | Sqm | 141.11 | 141.11 | 172.3527 | False | None | None | False | None | False | 24320.689497 | 0 | 3720759 | 137833 | None | Code33 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Common SR,Vol.II P.No 45 I.no 8.28 | Sqm | 91.67 | 91.67 | 105.7097 | False | None | None | False | None | False | 9690.408199 | 0 | 3720760 | 137833 | None | Code34 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Common SR,Vol.II P.No 48 i no 8.41 | Sqm | 172.01 | 172.01 | 33.3225 | False | None | None | False | None | False | 5731.803225 | 0 | 3720761 | 137833 | None | Code35 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.2023-24 Common SR,Vol.II P.No 123 i.no 13.34 | Ltr | 9.27 | 9.27 | 1000.0 | False | None | None | False | None | False | 9270.0 | 0 | 3720762 | 137833 | None | Code36 | White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap with C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 Common SR,Vol.II P.No 133 I.no 14.7.7 | Each | 2161.97 | 2161.97 | 4.0 | False | None | None | False | None | False | 8647.88 | 0 | 3720763 | 137833 | None | Code37 | Providing and fixing PVC (S.W.R) Gully/nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete Common SR,Vol.II P.No 127 I.no 13.58 | Each | 356.38 | 356.38 | 11.0 | False | None | None | False | None | False | 3920.18 | 0 | 3720764 | 137833 | None | Code38 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works RCC Pipe NP 3 heavy duty non presure pipe 1200 mm dia .2023-24 Common SR,Vol.III P.No A-13 Sl.no 102 | Mtr | 6808.3 | 6808.3 | 3.0 | False | None | None | False | None | False | 20424.9 | 0 | 3720765 | 137833 | None | Code39 | Supplying heavy gauge PVC conduit pipe mm
dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick Electrical PWD SR 2023-24 p.no 2 i.no 1.2.2 | Mtr | 78.0 | 78.0 | 20.0 | False | None | None | False | None | False | 1560.0 | 0 | 3720766 | 137833 | None | Code40 | Supplying heavy gauge PVC Conduit Pipe .... dia mm
thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick Electrical PWD SR 2023-24 p.no 2 i no 1.3.2 | Mtr | 79.0 | 79.0 | 20.0 | False | None | None | False | None | False | 1580.0 | 0 | 3720767 | 137833 | None | Code41 | Supplying and fixing PVC/metal conduit Deep junction box 32mm junction box Electrical PWD SR 2023-24 p.no 3 i no 1.5.3 | Each | 61.0 | 61.0 | 8.0 | False | None | None | False | None | False | 488.0 | 0 | 3720768 | 137833 | None | Code42 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch PWD SR 2023-24 vol no 6 p.no 5 i no 2.1.1 | Point | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 | 3720769 | 137833 | None | Code43 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch PWD SR 2023-24 vol no 6 p.no 5 i no 2.1.2 | Point | 394.0 | 394.0 | 8.0 | False | None | None | False | None | False | 3152.0 | 0 | 3720770 | 137833 | None | Code44 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 mm2 PWD SR 2023-24 vol no 6 p.no 5 i no 2.3.3 | Mtr | 42.0 | 42.0 | 60.0 | False | None | None | False | None | False | 2520.0 | 0 | 3720771 | 137833 | None | Code45 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3 Way PWD SR 2023-24 vol no 6 p.no 8 i no 3.4.1 | Each | 128.0 | 128.0 | 4.0 | False | None | None | False | None | False | 512.0 | 0 | 3720772 | 137833 | None | Code46 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way PWD SR 2023-24 vol no 6 p.no 8 i no 3.4.2 | Each | 159.0 | 159.0 | 4.0 | False | None | None | False | None | False | 636.0 | 0 | 3720773 | 137833 | None | Code47 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1-3 Way PWD SR 2023-24 vol no 6 p.no 8 i no 3.5.1 | Each | 137.0 | 137.0 | 4.0 | False | None | None | False | None | False | 548.0 | 0 | 3720774 | 137833 | None | Code48 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4- module PWD SR 2023-24 vol no 6 p.no 8 i no 3.5.3 | Each | 175.0 | 175.0 | 4.0 | False | None | None | False | None | False | 700.0 | 0 | 3720775 | 137833 | None | Code49 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal Socket PWD SR 2023-24 vol no 6 p.no 9 i no 3.6.10 6/16A Universal Socket | Each | 236.0 | 236.0 | 4.0 | False | None | None | False | None | False | 944.0 | 0 | 3720776 | 137833 | None | Code50 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch PWD SR 2023-24 vol no 6 p.no 9 i no 3.6.1 | No | 102.0 | 102.0 | 12.0 | False | None | None | False | None | False | 1224.0 | 0 | 3720777 | 137833 | None | Code51 | Supplying & Fixing of 70-150 W lamp holder 2 Pin PWD SR 2023-24 vol no 6 p.no 52 i no 12.46 | Each | 63.0 | 63.0 | 12.0 | False | None | None | False | None | False | 756.0 | 0 | 3720778 | 137833 | None | Code52 | Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 9W, 6500K PWD SR 2023-24 vol no 6 p.no 47 i no 11.11.4 | Each | 154.0 | 154.0 | 12.0 | False | None | None | False | None | False | 1848.0 | 0 |
|