1724760528000 | 0 | None | None | Other Works | Construction of TOILET BLOCK at Sy.no 45 of yeladur village in TMC Srinivaspura | 464687.51 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3866872 | 148109 | None | Code 1 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.2.5 (ii) By Mechanical Means using DozerB In area of thorny jungle ha (V-3,/P.No.9/I-2.5 | 100 Sqm | 498.52 | 498.52 | 0.25 | False | None | None | False | None | False | 124.63 | 0 | 3866873 | 148109 | None | Code 2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m(V-1,/P.No.8 /I-1.14.1) | Cum | 105.06 | 105.06 | 12.054 | False | None | None | False | None | False | 1266.39324 | 0 | 3866874 | 148109 | None | Code 3 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work(V-1,/P.No.8 /I-1.15.1) In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 373.89 | 373.89 | 3.0135 | False | None | None | False | None | False | 1126.717515 | 0 | 3866875 | 148109 | None | Code 4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead &lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurt enances required to complete the work as per technical specifications. Mix1:3:6(M10) Using 40mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately) (V-1,/P.No.15, I-2.1.3) | Cum | 6168.67 | 6168.67 | 2.396 | False | None | None | False | None | False | 14780.13332 | 0 | 3866876 | 148109 | None | Code 5 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coaSDe sand) ( P.No.9/Vol-2/5.4) | Cum | 6580.67 | 6580.67 | 12.25 | False | None | None | False | None | False | 80613.2075 | 0 | 3866877 | 148109 | None | Code 6 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ( P.No.16/Vol-1/2.3.1) | Cum | 10067.44 | 10067.44 | 1.26 | False | None | None | False | None | False | 12684.9744 | 0 | 3866878 | 148109 | None | Code 7 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications ( P.No.17/Vol-1/2.5.1) | Cum | 11224.64 | 11224.64 | 0.695 | False | None | None | False | None | False | 7801.1248 | 0 | 3866879 | 148109 | None | Code 8 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications ( P.No.17/Vol-1/2.5.1) | Cum | 10541.75 | 10541.75 | 2.1 | False | None | None | False | None | False | 22137.675 | 0 | 3866880 | 148109 | None | Code 9 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications ( P.No.17/Vol-1/2.5.1) | Cum | 10200.31 | 10200.31 | 0.159 | False | None | None | False | None | False | 1621.84929 | 0 | 3866881 | 148109 | None | Code 10 | Steel Fabrication
Supplying, fitting and placing TMT FE 550 / 550D SteelReinforcement
including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification. ( .P.No.18/Vol-1/2.11) | Tonne | 92140.71 | 92140.71 | 0.349 | False | None | None | False | None | False | 32157.10779 | 0 | 3866882 | 148109 | None | Code 11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ( P.No.115/Vol-1/1.9) Filling. | Cum | 273.98 | 273.98 | 6.735 | False | None | None | False | None | False | 1845.2553 | 0 | 3866883 | 148109 | None | Code 12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ( P.No.17/Vol-2/6.32) | Sqm | 1349.3 | 1349.3 | 37.08 | False | None | None | False | None | False | 50032.044 | 0 | 3866884 | 148109 | None | Code 13 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.No.17/Vol-2/6.33) | Sqm | 1267.93 | 1267.93 | 10.35 | False | None | None | False | None | False | 13123.0755 | 0 | 3866885 | 148109 | None | Code 14 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement: 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( P.No.42/Vol-2/8.8) | Sqm | 382.13 | 382.13 | 39.18 | False | None | None | False | None | False | 14971.8534 | 0 | 3866886 | 148109 | None | Code 15 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(P.No.42/Vol-2/8.7) | Sqm | 376.98 | 376.98 | 63.555 | False | None | None | False | None | False | 23958.9639 | 0 | 3866887 | 148109 | None | Code 16 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in- charge.( P.No.41/Vol-2/8.1.2) | Sqm | 248.23 | 248.23 | 10.0 | False | None | None | False | None | False | 2482.3 | 0 | 3866888 | 148109 | None | Code 17 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).( P.No.62/Vol-2/9.21.2) Size of Tile 600x600 mm. | Sqm | 1275.14 | 1275.14 | 9.61 | False | None | None | False | None | False | 12254.0954 | 0 | 3866889 | 148109 | None | Code 18 | Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineerin- charge. ( P.No.44/Vol-2/8.21 | Sqm | 26.78 | 26.78 | 9.61 | False | None | None | False | None | False | 257.3558 | 0 | 3866890 | 148109 | None | Code 19 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge.( P.No.46/Vol- 2/8.31) | Sqm | 183.34 | 183.34 | 39.18 | False | None | None | False | None | False | 7183.2612 | 0 | 3866891 | 148109 | None | Code 20 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( P.No.46/Vol-2/8.33) | Sqm | 162.74 | 162.74 | 63.555 | False | None | None | False | None | False | 10342.9407 | 0 | 3866892 | 148109 | None | Code 21 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No.48/Vol-2/8.40) | Sqm | 118.45 | 118.45 | 0.72 | False | None | None | False | None | False | 85.284 | 0 | 3866893 | 148109 | None | Code 22 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ( P.No.86/Vol-2/11.34A) | Kgs | 173.04 | 173.04 | 60.0 | False | None | None | False | None | False | 10382.4 | 0 | 3866894 | 148109 | None | Code 23 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.( P.No.100/Vol-2/12.13.1) | Cum | 101779.45 | 101779.45 | 0.128 | False | None | None | False | None | False | 13027.7696 | 0 | 3866895 | 148109 | None | Code 24 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) .( P.No.100/Vol-2/12.15) | Sqm | 7667.32 | 7667.32 | 1.575 | False | None | None | False | None | False | 12076.029 | 0 | 3866896 | 148109 | None | Code 25 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part- I) 1991. from manufacturer complete as per spcification.( P.No.105/Vol-2/12.57.4) -do- 35 mm
thick both side Teak | Sqm | 4667.96 | 4667.96 | 3.15 | False | None | None | False | None | False | 14704.074 | 0 | 3866897 | 148109 | None | Code 26 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (P.No.105/Vol-2/12.62) | Nos | 244.11 | 244.11 | 3.0 | False | None | None | False | None | False | 732.33 | 0 | 3866898 | 148109 | None | Code 27 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. (P.No.105/Vol-2/12.61) | Nos | 640.0 | 640.0 | 3.0 | False | None | None | False | None | False | 1920.0 | 0 | 3866899 | 148109 | None | Code 28 | Providing and fixing aluminium tower
bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ( P.No.105/Vol-2/12.63) | Nos | 133.9 | 133.9 | 3.0 | False | None | None | False | None | False | 401.7 | 0 | 3866900 | 148109 | None | Code 29 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. ( P.No.105/Vol-2/12.58) | Nos | 123.6 | 123.6 | 3.0 | False | None | None | False | None | False | 370.8 | 0 | 3866901 | 148109 | None | Code 30 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked black solid plastic seat and lid( P.No.131/Vol-2/14.2.2) | Each | 4980.05 | 4980.05 | 1.0 | False | None | None | False | None | False | 4980.05 | 0 | 3866902 | 148109 | None | Code 31 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making goodthe walls wherever require:( P.No.132/Vol-2/14.7.2)White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass
pillar tap | Each | 2637.83 | 2637.83 | 1.0 | False | None | None | False | None | False | 2637.83 | 0 | 3866903 | 148109 | None | Code 32 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.(/P.No.136/Vol-2/14.28.1.1) | Each | 78.28 | 78.28 | 2.0 | False | None | None | False | None | False | 156.56 | 0 | 3866904 | 148109 | None | Code 33 | Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00 kgs/sqcm working pressure with pipe fittings, wall clips etc., and making good the wall, ceiling and floor for sanitary pipelines including cost of all materials, labour charges, HOM of acquirements and testing complete as per specifications. - 110mm dia (vol 2 /P.No 88/12.116.1) | Mtr | 447.02 | 447.02 | 20.0 | False | None | None | False | None | False | 8940.4 | 0 | 3866905 | 148109 | None | Code 34 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. ( . P.No. 10/Vol-1/ 1.17.1 ) All kinds of soils. Depth upto 1.50 m | Cum | 269.86 | 269.86 | 22.95 | False | None | None | False | None | False | 6193.287 | 0 | 3866906 | 148109 | None | Code 35 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc ( vol 5 P.No.95, I.No.9.1.4) K010D HDPEGrade PE80-PN6.0,110mm dia | Mtr | 483.07 | 483.07 | 30.0 | False | None | None | False | None | False | 14492.1 | 0 | 3866907 | 148109 | None | Code 36 | Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge ofwork and latest amendments (vol 5 P.No.149, I.No.13.4.1) P040A 0.50 HP/0.37kW - 5 STG(stage) | Each | 10475.1 | 10475.1 | 1.0 | False | None | None | False | None | False | 10475.1 | 0 | 3866908 | 148109 | None | Code 37 | Providing and fixing Chorinated PolyVenyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per the direction of engineer incharge of work.external work. - 32mm nominal dia pipes ( P.No. 122/Vol-2/ 13.33.4 ) | Mtr | 383.16 | 383.16 | 20.0 | False | None | None | False | None | False | 7663.2 | 0 | 3866909 | 148109 | None | Code 38 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.0m spacing. this includes jointing of pipes and fittings with one step solvent cementand the cost of cutting chase and making good the same including testing of joints complete as per the direction of engineer incharge of work Conclead work, including cutting chase and making good the walls etc - 20mm nominal dia pipes ( PWD SR 2021-22 P.No. 8/Vol-2/ 13.32.2 ) | Mtr | 390.37 | 390.37 | 20.0 | False | None | None | False | None | False | 7807.4 | 0 | 3866910 | 148109 | None | Code 39 | Cutting holes upto 30x30 cm in walls including making good the same : with common burnt clay F.P.S (non-modular) Bricks (CM SR 2021-22 P.No. 119/Vol-2/ 13.36) | Each | 274.0 | 274.0 | 10.0 | False | None | None | False | None | False | 2740.0 | 0 | 3866911 | 148109 | None | Code 40 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore ( . P.No. 115/Vol-1/13.2.2) | Each | 355.0 | 355.0 | 5.0 | False | None | None | False | None | False | 1775.0 | 0 | 3866912 | 148109 | None | Code 41 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore ( P.No.115/Vol-1/13.4.2) | Each | 594.0 | 594.0 | 2.0 | False | None | None | False | None | False | 1188.0 | 0 | 3866913 | 148109 | None | Code 42 | Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). - 10cms x 7.5cms (NORTH ZONE PWD SR 2018-19/P.No 90/12.113.1) | Each | 258.0 | 258.0 | 5.0 | False | None | None | False | None | False | 1290.0 | 0 | 3866914 | 148109 | None | Code 43 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps
complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern ( . P.No. 131/Vol-2/ 14.4.1) | Each | 4587.62 | 4587.62 | 2.0 | False | None | None | False | None | False | 9175.24 | 0 | 3866915 | 148109 | None | Code 44 | Constructing brick masonry inspection chamber 450x450mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non- modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 450x450mm and 450mm depth ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 450x450mm (NORTH ZONE PWD SR2018-19/P.No 75/11.50.3) | Nos | 5719.0 | 5719.0 | 2.0 | False | None | None | False | None | False | 11438.0 | 0 | 3866916 | 148109 | None | Code 45 | Providing and placing on terrace (at all floor levels) polyethylene water storage tanks, IS : 12701marked with cover and suitable locking arrangements, making necessary holes for inlet, outlet and over flow pipes but with out fittings and the base support for tank ( . P.No. 128/Vol-2/ 13.34) | Ltr | 9.27 | 9.27 | 1000.0 | False | None | None | False | None | False | 9270.0 | 0 |
|