3867679 | 148141 | None | code 1 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.[PWD SR 2023-24 Vol:2 P.NO.65 I.No: 9.38] | Sqm | 1433.76 | 1433.76 | 122.805 | False | None | None | False | None | False | 176072.8968 | 0 |
3867680 | 148141 | None | code 2 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.[PWD SR 2023-24 Vol:2 P.NO.44 I.No: 8.19.1] | Sqm | 262.65 | 262.65 | 14.92 | False | None | None | False | None | False | 3918.738 | 0 |
3867681 | 148141 | None | code 3 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) Size of Tile 500x500 mm [PWD SR 2023-24 Vol:2 P.NO.62 I.No:9.12.1] | Sqm | 1114.46 | 1114.46 | 23.93 | False | None | None | False | None | False | 26669.0278 | 0 |
3867682 | 148141 | None | code 4 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete.[PWD SR 2023-24 Vol:2 P.NO.138 I.No:14.44] | Each | 11560.72 | 11560.72 | 8.0 | False | None | None | False | None | False | 92485.76 | 0 |
3867683 | 148141 | None | code 5 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests [PWD SR 2023-24 Vol:2 P.NO.131 I.No:14.1.1] | Each | 5030.52 | 5030.52 | 2.0 | False | None | None | False | None | False | 10061.04 | 0 |
3867684 | 148141 | None | code 6 | Providing and fixing Single lever wall mixer made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Premium Class [PWD SR 2023-24 Vol:2 P.NO.140 I.No:14.59 b] | Each | 8291.5 | 8291.5 | 6.0 | False | None | None | False | None | False | 49749.0 | 0 |
3867685 | 148141 | None | code 7 | Providing and fixing Exposed set for single lever concealed basin mixer Single lever sink mixer made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete Premium Class [PWD SR 2023-24 Vol:2 P.NO.141 I.No:14.65 b] | Each | 3919.15 | 3919.15 | 2.0 | False | None | None | False | None | False | 7838.3 | 0 |
3867686 | 148141 | None | code 8 | Providing and fixing Temperature controlled Overhead rain showers with LED of minimum dimension 225x225mm & wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class [PWD SR 2023-24 Vol:2 P.NO.143 I.No:14.82 b] | Each | 11012.76 | 11012.76 | 2.0 | False | None | None | False | None | False | 22025.52 | 0 |
3867687 | 148141 | None | code 9 | Providing and fixing Stainless Steel Foldable Towel Rack 600 mm Long with all concealed fitting arrangements & all necessary accessories complete - Class [PWD SR 2023-24 Vol:2 P.NO.145 I.No:14.97 b] | Each | 4340.42 | 4340.42 | 2.0 | False | None | None | False | None | False | 8680.84 | 0 |
3867688 | 148141 | None | code 10 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm [PWD SR 2023-24 Vol:2 P.NO.136 I.No:14.32.2] | Each | 1048.54 | 1048.54 | 2.0 | False | None | None | False | None | False | 2097.08 | 0 |
3867689 | 148141 | None | code 11 | Providing and fixing M.S. grills of required pattern in frames of win dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. [PWD SR 2023-24 Vol:1 P.NO.7 I.No:11.34B] | Kg | 188.49 | 188.49 | 210.0 | False | None | None | False | None | False | 39582.9 | 0 |
3867690 | 148141 | None | code 12 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. [PWD SR 2023-24 Vol:2 P.NO.99 I.No:12.12] | Cum | 127928.06 | 127928.06 | 0.2028 | False | None | None | False | None | False | 25943.810568 | 0 |
3867691 | 148141 | None | code 13 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) [PWD SR 2023-24 Vol:2 P.NO.100 I.No:12.15] | Sqm | 7103.91 | 7103.91 | 3.78 | False | None | None | False | None | False | 26852.7798 | 0 |
3867692 | 148141 | None | code 14 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. [PWD SR 2023-24 Vol:2 P.NO.100 I.No:12.84] | Mtr | 327.54 | 327.54 | 58.0 | False | None | None | False | None | False | 18997.32 | 0 |
3867693 | 148141 | None | code 15 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges [PWD SR 2023-24 Vol:2 P.NO.105 I.No:12.53] | Sqm | 1635.64 | 1635.64 | 15.75 | False | None | None | False | None | False | 25761.33 | 0 |
3867694 | 148141 | None | code 16 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) [PWD SR 2023-24 Vol:2 P.NO.108 I.No:12.84] | Sqm | 5173.69 | 5173.69 | 1.8 | False | None | None | False | None | False | 9312.642 | 0 |
3867695 | 148141 | None | code 17 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 600x450x200 mm [PWD SR 2023-24 Vol:2 P.NO.126 I.No:14.11.2] | Each | 5234.46 | 5234.46 | 2.0 | False | None | None | False | None | False | 10468.92 | 0 |
3867696 | 148141 | None | code 18 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall [PWD SR 2023-24 Vol:2 P.NO.122 I.No:13.31.2] | Mtr | 249.26 | 249.26 | 70.0 | False | None | None | False | None | False | 17448.2 | 0 |
3867697 | 148141 | None | code 19 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 20 mm dia GM (Copper alloy) Gate valves [Common SR Water Supply 2023-24 Vol:2 P.NO.133 I.No:11.15.2] | Each | 914.64 | 914.64 | 2.0 | False | None | None | False | None | False | 1829.28 | 0 |
3867698 | 148141 | None | code 20 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 65x50 Head 13M, Discharge 462 LPM [Common SR Water Supply 2023-24 Vol:5 P.NO.157 I.No:13.40.1] | Each | 15887.75 | 15887.75 | 1.0 | False | None | None | False | None | False | 15887.75 | 0 |
3867699 | 148141 | None | code 21 | Supply and delivery at site brand new best make Foot valve suitable for centrifugal pump upto 10HP confirming with ISI mark and its latest amendments [Common SR Water Supply 2023-24 Vol:5 P.NO.158 I.No:13.47] | Each | 1802.5 | 1802.5 | 1.0 | False | None | None | False | None | False | 1802.5 | 0 |
3867700 | 148141 | None | code 22 | Supply and delivery at site brand new best make starter/ control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments.Upto 7.5 HP centrifugal pump [Common SR Water Supply 2023-24 Vol:5 P.NO.157 I.No:13.43.1] | Each | 9785.0 | 9785.0 | 1.0 | False | None | None | False | None | False | 9785.0 | 0 |
3867701 | 148141 | None | code 23 | Supplying and fixing LT cable of size 4 x 25 Sqm suitable for centrifugal pump sets with ISI mark and its latest amendments [Common SR Water Supply 2023-24 Vol:5 P.NO.158 I.No:13.46] | Mtr | 578.86 | 578.86 | 15.0 | False | None | None | False | None | False | 8682.9 | 0 |
3867702 | 148141 | None | code 24 | 13.34 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank[Common SR Water Supply 2023-24 Vol:2 P.NO.123 I.No:13.34] | Each | 9.0 | 9.0 | 2000.0 | False | None | None | False | None | False | 18000.0 | 0 |
3867703 | 148141 | None | code 25 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia.,And 160mm dia , 6 kg/sqcm & class 3 [Common SR Water Supply 2023-24 Vol:5 P.NO.113 I.No:10.1.7] | Mtr | 423.33 | 423.33 | 30.0 | False | None | None | False | None | False | 12699.9 | 0 |
3867704 | 148141 | None | code 26 | Supplying heavy gauge PVC conduit pipe 20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 1 I.No:1.1.1] | Mtr | 69.0 | 69.0 | 33.04 | False | None | None | False | None | False | 2279.76 | 0 |
3867705 | 148141 | None | code 27 | Supplying and fixing PVC/metal conduit 19/20 mm deep Junction box [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 1 I.No:1.5.1 | Each | 49.0 | 49.0 | 4.0 | False | None | None | False | None | False | 196.0 | 0 |
3867706 | 148141 | None | code 28 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete 8" x 6" x 3" (203 x 152 x 76 mm) [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 1 I.No:1.6.4] | Each | 86.0 | 86.0 | 10.0 | False | None | None | False | None | False | 860.0 | 0 |
3867707 | 148141 | None | code 29 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and atest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a Wood/PVC round block. complete for each outlet Short point upto 3m from tapping point to out let via switch [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 2 I.No:2.1.1] | Point | 285.0 | 285.0 | 5.0 | False | None | None | False | None | False | 1425.0 | 0 |
3867708 | 148141 | None | code 30 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and atest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a Wood/PVC round block. complete for each outlet Long point above 6m upto 10m from tapping point to out let via switch [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 2 I.No:2.1.3] | Point | 570.0 | 570.0 | 2.0 | False | None | None | False | None | False | 1140.0 | 0 |
3867709 | 148141 | None | code 31 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5Sqmm [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 5 I.No:2.3.3] | Mtr | 42.0 | 42.0 | 30.0 | False | None | None | False | None | False | 1260.0 | 0 |
3867710 | 148141 | None | code 32 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 1 to 2 Module [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 8 I.No:3.5.1] | Each | 137.0 | 137.0 | 10.0 | False | None | None | False | None | False | 1370.0 | 0 |
3867711 | 148141 | None | code 33 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 9 I.No:3.6.3] | Each | 171.0 | 171.0 | 20.0 | False | None | None | False | None | False | 3420.0 | 0 |
3867712 | 148141 | None | code 34 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator Two Module [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 9 I.No:3.6.4] | Each | 357.0 | 357.0 | 8.0 | False | None | None | False | None | False | 2856.0 | 0 |
3867713 | 148141 | None | code 35 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A SP Switch [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 10 I.No:3.14.1] | No | 55.0 | 55.0 | 10.0 | False | None | None | False | None | False | 550.0 | 0 |
3867714 | 148141 | None | code 36 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Two Way Switch [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 6 I.No:3.14.2] | No | 70.0 | 70.0 | 10.0 | False | None | None | False | None | False | 700.0 | 0 |
3867715 | 148141 | None | code 37 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA [PWD SR 2023-24 Electrical SR Chapter-1 P.NO.21 I.No:5.46.6] | Each | 1195.0 | 1195.0 | 2.0 | False | None | None | False | None | False | 2390.0 | 0 |
3867716 | 148141 | None | code 38 | Supplying & fixing retrofit type-PL- LED Lamp 8-9 W LED linear source [PWD SR 2023-24 Electrical SR Chapter-1 P.NO.43 I.No:11.2.1] | Each | 623.0 | 623.0 | 3.0 | False | None | None | False | None | False | 1869.0 | 0 |
3867717 | 148141 | None | code 39 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2 12 Way [PWD SR 2023-24 Electrical SR Chapter-1 P.NO.17 I.No:5.17.3] | Each | 15529.0 | 15529.0 | 1.0 | False | None | None | False | None | False | 15529.0 | 0 |
3867718 | 148141 | None | code 40 | Providing main connection from pole PVC insulated sheathed steel wire cable in GI pipe as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit [Water Supply SR 2021-22 P.NO.164 I.No:43] | Mtr | 82.4 | 82.4 | 10.0 | False | None | None | False | None | False | 824.0 | 0 |
3867719 | 148141 | None | code 41 | Providing,Supplying and fixing suitable for 1.1 KV class UG cable filled with necesterminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer inch [Water Supply SR 2021-22 P.NO.164 I.No:43] | Each | 767.35 | 767.35 | 2.0 | False | None | None | False | None | False | 1534.7 | 0 |
3867720 | 148141 | None | code 42 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia[Water Supply SR 2021-22 P.NO.164 I.No:44] | Job | 3862.5 | 3862.5 | 2.0 | False | None | None | False | None | False | 7725.0 | 0 |
3867721 | 148141 | None | code 43 | Providing lowering laying, jointing, testing and commissioning of following diameters glazed stone ware pipes, conforming to IS 651:1992, (with 5th revision) in all respects jointing with EPDM rubber rings (seals according to EN 681 & ASPM 425) The rubber seals joints pipe will have groves in interior of socket and exterior of the spigot. The rubber gasket shall be prefixed at the factory by the manufacturer rigidly with approved glue to have leak proof joint including conveying of pipe to
work site and rolling and lowering into trenches, laying true to line, level and perfect linking at joints testing and commissoning including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of GSW pipes and specials, with rubber gaskets conforming to EN 681 and ASTM C-425 including cleaning the socket and spigot with soap solution and applying talcum powder for detecting crack, then applying glue and before inserting of rubber
gaskets, jacking and fixing in perfect condition including the cost of soap solution, talcum powder and glue etc. and giving necessary hydraulic test
to the required pressure of water head with all lead and lifts including costing of jointing materials and all necessary survey works for laying of sewers etc., and disposal of debris as directed etc., complete. (Contractor will make his own arrangements for procuring water for testing) with
Rubber ring gasket joints16.2.1
16.2.2, 150 mm dia. pipes m 624 | Mtr | 642.72 | 642.72 | 80.0 | False | None | None | False | None | False | 51417.6 | 0 |
3867722 | 148141 | None | code 44 | 16.8 Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing
CI cover & frame etc. excluding the cost of CI frame and cover.Each 4791 | Each | 4934.73 | 4934.73 | 2.0 | False | None | None | False | None | False | 9869.46 | 0 |
3867723 | 148141 | None | code 45 | Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using ortland/ Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber.Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia:16.15.1 Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frameEach 29047 | Nos | 29918.41 | 29918.41 | 2.0 | False | None | None | False | None | False | 59836.82 | 0 |