createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1724394061786
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd23300.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose04-09-2024 16:00:00
tenderQueryClose03-09-2024 11:00:00
technicalBidOpenNone
publishedDate28-08-2024 09:50:49
publishedByPostPWD_EE_DIV_RCR
publishedByUserKPE15695 - K SHANKAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonChandrashekar TA
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08532225778
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1724394061821
version6
createdDateNone
modifiedDateNone
tenderNumberPWD/2024-25/BD/WORK_INDENT13817
titleProviding and Installation of Solar System, and Construction of Toilet Room at Govt High School Navalkal Village in Siriwara Taluka of Raichur District Work code RCH2318231843.
descriptionProviding and Installation of Solar System, and Construction of Toilet Room at Govt High School Navalkal Village in Siriwara Taluka of Raichur District Work code RCH2318231843.
categoryWORKS
categoryTextWorks
ecv929903.27
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1695
locationNamePWD Division Office Raichuru
provisionalAmount1080000.0
groupOverheadTotal0.0
fileNumberPWD/AEE/MNV/SD/BD/Navalkal/KKRDB/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17243940620000NoneNoneBuildingsProviding and Insrallation of Solar System, and Construction of Toilet Room at Govt High School Navalkal Village in Siriwara Taluka of Raichur District770579.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3842033146625NonePWD CSR VOL I 2023-24. I. No. 1.14.1 Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum107.1107.110.89FalseNoneNoneFalseNoneFalse1166.3190
3842034146625NonePWD SR.2023-24 V1 Pg-5 Item No.1.4.1 Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Cum254.1254.113.95FalseNoneNoneFalseNoneFalse3544.6950
3842035146625NonePWD SR.2023-24 V1 Pg-15 Item No.2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates Cum5947.25947.25.35FalseNoneNoneFalseNoneFalse31817.520
3842036146625NonePWD SR.2023-24 V2 Pg-9 Item No.5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6515.256515.257.29FalseNoneNoneFalseNoneFalse47496.17250
3842037146625NonePWD SR.2023-24 V2 Pg-9 Item No.5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Cum6708.456708.453.64FalseNoneNoneFalseNoneFalse24418.7580
3842038146625NonePWD DSR.2023-24 V1 Pg-7 Item No1.9 Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m Cum279.3279.32.44FalseNoneNoneFalseNoneFalse681.4920
3842039146625NonePWD SR.2023-24 V2 Pg-14 Item No.6.8 Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8367.458367.4514.01FalseNoneNoneFalseNoneFalse117227.97450
3842040146625NonePWD SR.2023-24 V2 Pg-14 Item No.6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1084.651084.6516.56FalseNoneNoneFalseNoneFalse17961.8040
3842041146625NonePWD SR.2023-24 V1 Pg-17 Item No.2.4.2Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum6639.156639.152.15FalseNoneNoneFalseNoneFalse14274.17250
3842042146625NonePWD SR.2023-24 V1 Pg-112 Item No.14 Formwork for footing 8 percentCum531.13531.132.15FalseNoneNoneFalseNoneFalse1141.92950
3842043146625NonePWD SR.2023-24 V1 Pg-17 Item No.2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum6961.56961.56.9FalseNoneNoneFalseNoneFalse48034.350
3842044146625NonePWD SR.2023-24 V1 Pg-112 Item No.15Formwork for toilet Slab For Form work 50% Cum3480.753480.756.9FalseNoneNoneFalseNoneFalse24017.1750
3842045146625NonePWD SR.2023-24 V1 Pg-18 Item No.2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings Tonne93929.8593929.850.81FalseNoneNoneFalseNoneFalse76083.17850
3842046146625NonePWD SR.2023-24 V2 Pg-42 Item No.8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm366.45366.45124.86FalseNoneNoneFalseNoneFalse45754.9470
3842047146625NonePWD SR.2023-24 V2 Pg-71 Item No.10.14Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.Sqm1161.31161.327.63FalseNoneNoneFalseNoneFalse32086.7190
3842048146625NonePWD SR.2023-24 V2 Pg-86 Item No.11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Kg176.4176.413.5FalseNoneNoneFalseNoneFalse2381.40
3842049146625NonePWD SR.2023-24 V2 Pg-60 Item No.9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Sqm933.45933.4530.0FalseNoneNoneFalseNoneFalse28003.50
3842050146625NonePWD SR.2023-24 V2 Pg-45 Item No.8.28 Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm93.4593.4550.8FalseNoneNoneFalseNoneFalse4747.260
3842051146625NonePWD SR.2023-24 V2 Pg-45 Item No.8.25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm143.85143.85143.82FalseNoneNoneFalseNoneFalse20688.5070
3842052146625NonePWD SR.2023-24 V2 Pg-77 Item No. 11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm4454.14454.13.24FalseNoneNoneFalseNoneFalse14431.2840
3842053146625NonePWD SR 2023-24, V-2 I No.12.54 P-105Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.Nos333.9333.910.2FalseNoneNoneFalseNoneFalse3405.780
3842054146625NonePWD SR 2023-24, V-2 I No.12.55.2 P-106Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with one side prelamSqm2142.02142.02.7FalseNoneNoneFalseNoneFalse5783.40
3842055146625NonePWD SR.2023-24 V2 Pg-123 I.No.13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base suooort for tank.Per Litre9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
3842056146625NonePWD SR.2023-24 V2 Pg-123 I.No.13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal dia Pipesm562.8562.830.0FalseNoneNoneFalseNoneFalse16884.00
3842057146625NonePWD SR.2023-24 V2 Pg-A-123 Item No.14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Pan5128.25128.22.0FalseNoneNoneFalseNoneFalse10256.40
3842058146625NonePWD SR.2023-24 V2 Pg-A-123 Item No.14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern Each4676.74676.76.0FalseNoneNoneFalseNoneFalse28060.20
3842059146625NoneRWS SR.2023-24 V5 Pg-149 Item No.13.4 Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments.0.50 HP/0.37kW - 5 STG(stage) Each10678.510678.51.0FalseNoneNoneFalseNoneFalse10678.50
3842060146625NoneRWS SR.2023-24 V5 Pg-161 Item No.13.22.1Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.1x3x1.5 m2m68.2568.2520.0FalseNoneNoneFalseNoneFalse1365.00
3842061146625NonePWD SR 2023-24, V-2 I No:13.2.1 P-117Providing and fixing brass bib cock of approved quality : 15 mm nominal bore Nos300.3300.38.0FalseNoneNoneFalseNoneFalse2402.40
3842062146625NonePWD SR 2023-24, V-1 I No:1.6.1 P-32Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. - In all kinds of soils. Depth upto 1.50m Cum508.2508.24.05FalseNoneNoneFalseNoneFalse2058.210
3842063146625NonePWD SR 2023-24, V-1 I No:1.10 P-35Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications Cum168.0168.04.05FalseNoneNoneFalseNoneFalse680.40
3842064146625NoneBWSSB SR 2023-24, V-5 I No:10.2.2 P-114Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia.m302.4302.425.0FalseNoneNoneFalseNoneFalse7560.00
3842065146625NonePWD SR 2023-24, II-5 I No:13.56 P-127Making soak pit 2.5 m diameter 3.0 m deep with 45 x 45 cm dry brick honey comb shaft with bricks and PVC S.W.R drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay (non modular) bricks of class designation 3.5 Rate including GST 18 percent" Per Pit24175.224175.22.0FalseNoneNoneFalseNoneFalse48350.40
3842066146625NonePWD SR 2023-24, II-5 I No:13.34 P-123Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both estinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia.Per Litre9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
3842067146625NoneCommon SR Vol.3 I.No. 3.6 P.No .17Construction of Subgrade and Earthen Shoulders .Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads,transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2Cum517.65517.65112.5FalseNoneNoneFalseNoneFalse58235.6250
17243940620000NoneNoneBuildingsElectrical estimate9823.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3842068146626NoneVol-6 PART-3 Chapter-1 It No - 1.2.1 Pg No.2 of105Concealed Conduit System Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessarym69.369.330.0FalseNoneNoneFalseNoneFalse2079.00
3842069146626NoneVol-6 PART-3 Chapter-2 It No - 2.2.1 Pg No.5of105Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistr and FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxPoint282.45282.452.0FalseNoneNoneFalseNoneFalse564.90
3842070146626NoneVol-6 PART-3 Chapter-2 It No - 2.2.2 Pg No.5of105Point wiring : Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxPoint397.95397.952.0FalseNoneNoneFalseNoneFalse795.90
3842071146626NonePART-3 Vol-6 Chapter-2 It No - 2.2.3 Pg No.5of105Point wiring : Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxPoint582.75582.753.0FalseNoneNoneFalseNoneFalse1748.250
3842072146626NoneVol-6 PART-3 Chapter-3 It No -3.14.6 Pg No.10of105Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 6Amps lamp holderEach74.5574.555.0FalseNoneNoneFalseNoneFalse372.750
3842073146626NoneVol-6 PART-3 Chapter-11 It No -11.3.2 Pg No.43of10Supplying of .feet - PVC Batten with integrated LED tube.W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V 5060Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Light fighting 1 42022 wEach724.5724.54.0FalseNoneNoneFalseNoneFalse2898.00
3842074146626NoneVol-6 PART-3 Chapter-13It No -13.7.1 Pg No.56of105Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersEach128.1128.12.0FalseNoneNoneFalseNoneFalse256.20
3842075146626NoneVol-6 PART-3 Chapter-13 It No -13.10 Pg No.57of105Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each179.55179.552.0FalseNoneNoneFalseNoneFalse359.10
3842076146626NoneVol-6 PART-3 Chapter-3 It No -3.6.4 Pg No.9of105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped fan regulator. Each374.85374.852.0FalseNoneNoneFalseNoneFalse749.70
17243940620000NoneNoneBuildingsProviding and Insrallation of Solar System149500.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3842077146627NoneGovt e MarketLiveguard Cabn be hung from the ceiling in a stable manner solar charge controller :24v,15A,SPV Module:300WP,Battery:12V,240A Solarr Lamps.Each149500.0149500.01.0FalseNoneNoneFalseNoneFalse149500.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17243940630000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17243940630000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17243940630001NoneNoneELIGIBILITYAs per Karnataka State Government order No LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No.PW/134/BMS/2007 Dated 27.07.2007, a sum amounting to 1%of the bill amount will be deducted towards Construction Labour Welfare fund.None
17243940630000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17243940630000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17243940630000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17243940630000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17243940630000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17243940630000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17243940630000NoneNoneELIGIBILITYBanker DetailsNone
17244078290000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17244078370000NoneNoneELIGIBILITYThe Tenderer shall obtain the required work done certificates from the Competent Authority not below the rank of Executive Engineer or equivalent.None
17244078470000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reason or what so ever.None
17244078560000NoneNoneELIGIBILITYThe Department is not responsible for any delay in accessing KPP portal.None
17244078650000NoneNoneELIGIBILITYThe proposed methodology and program of construction, backed with equipment planning and deployment, duly supported with broad calculations and quality control procedures proposed to be adopted, justifying their capability of execution and completion of the work as per technical specifications within the stipulated period of completion.None
17244078760000NoneNoneELIGIBILITYAgency shall comply with ISO14001 (Environmental Management System) requirement during execution of work.None
17244078840000NoneNoneELIGIBILITYAll safety precautions, warning signs, night illumination, reflectors, deployment of security guards has to be ensured so that no untoward incident happens on account of negligence or any project activity till completion. Contractor should indemnify the client to that extent.None
17244078930000NoneNoneELIGIBILITYContractor should adhere to HSE policy applicable for similar projects. Contractor to that extent should submit HSE document defining all the procedure including the policies before execution of the project.None
17244079020000NoneNoneELIGIBILITYContractor should follow strictly the prevailing rules of Labour Act and applicable any other law as concerned to work.None
17244079100000NoneNoneELIGIBILITYIf undue delay caused by the contractor, the progressive damages caused will be assessed and make good at the cost and risk of the contractor. In addition, suitable action will be initiated against the contractor for the damages occurred during the undue delay period in accordance with the Karnataka Highway Act, 1964.None
17244079200000NoneNoneELIGIBILITYIt is mandatory for the contractor to upload the work done certificate issued by an officer not below the rank of Executive Engineer duly indicating the work indent numbers for works costing more than Rs.5.00 lakhs.None
17244079300000NoneNoneELIGIBILITYThe Item Rate quoted shall be exclusive of GST, the Royalty Charges on construction materials and other taxes as per prevailing Government Orders.None
17244079380000NoneNoneELIGIBILITYIn the estimate, rates are considered exclusive of GST at 18%. The tenderer shall quote his rates excluding GST. It may be noted that GST will be paid seperately.None
17244079470000NoneNoneELIGIBILITYThe tenderer shall note that, the increase in GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delay as determined by the authority while granting the extension of time.None
17244079600000NoneNoneELIGIBILITYThe tender period for completion of work is 6 (Six) Calendar months. (Including monsoon period)None
17244079700000NoneNoneELIGIBILITYDefect liability period is One (1) year from the date of actual completion of the work.None
17244079850001NoneNoneELIGIBILITYIf the bidder quoted rates less than the estimated or amount put to tender rates , he has to remit the (unbalanced tenders ) difference amount in the form of DD or FDR drawn in favour of Executive Engineer, PWD Division, Raichur only, duly uploading the scanned copy of the same in the kpp-portal at the time of submitting the bid and the original shall be submitted to this office at the time of tender opening . Failing which the bid will be liable for rejection.None
17244079940000NoneNoneELIGIBILITYAll the specifications in the commercial bid format please be read as with all leads and lifts etc., complete as per specification and as directed by the engineer-in-charge.None
17244080020000NoneNoneELIGIBILITYThe Bidder will be qualified only if their available tender capacity is more than the total tender value of this work.None
17244080110000NoneNoneELIGIBILITYTENDERER MUST UPLOAD ELIGIBLE PWD REGISTRATION CERTIFICATE.None
17244260430000NoneNoneELIGIBILITYThe KPWD Code, KTTP Act/Rules ,Delegation of Powers and other Government Orders issued by the Government from time to time will apply.None
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
Workdone CertificateTrueTechnical Bid
Assesed tender capacity / Bid capacityTrueTechnical Bid
Less BG /FDR for unbalanced tender.TrueTechnical Bid
Any other relevant documents.TrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone