1724754133000 | 0 | None | None | Buildings | Construction of Ambulance Shed and Electrical Repair for veterinary Hospital Building in Mundaragi Town | 251990.71 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3865059 | 148033 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 102.0 | 102.0 | 14.11 | False | None | None | False | None | False | 1439.22 | 0 | 3865060 | 148033 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 5664.0 | 5664.0 | 1.75 | False | None | None | False | None | False | 9912.0 | 0 | 3865061 | 148033 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 5611.0 | 5611.0 | 5.6 | False | None | None | False | None | False | 31421.6 | 0 | 3865062 | 148033 | None | code04 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 6389.0 | 6389.0 | 2.5 | False | None | None | False | None | False | 15972.5 | 0 | 3865063 | 148033 | None | code05 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 433.0 | 433.0 | 4.37 | False | None | None | False | None | False | 1892.21 | 0 | 3865064 | 148033 | None | code06 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 5989.0 | 5989.0 | 1.46 | False | None | None | False | None | False | 8743.94 | 0 | 3865065 | 148033 | None | code07 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 6323.0 | 6323.0 | 1.8 | False | None | None | False | None | False | 11381.4 | 0 | 3865066 | 148033 | None | code08 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For column from footing to Top ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 11271.0 | 11271.0 | 1.52 | False | None | None | False | None | False | 17131.92 | 0 | 3865067 | 148033 | None | code09 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Roof Beam ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 10608.0 | 10608.0 | 1.23 | False | None | None | False | None | False | 13047.84 | 0 | 3865068 | 148033 | None | code10 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Roof Slab ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 9945.0 | 9945.0 | 2.95 | False | None | None | False | None | False | 29337.75 | 0 | 3865069 | 148033 | None | code11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Tonne | 89457.0 | 89457.0 | 0.54 | False | None | None | False | None | False | 48306.78 | 0 | 3865070 | 148033 | None | code12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 1105.0 | 1105.0 | 45.61 | False | None | None | False | None | False | 50399.05 | 0 | 3865071 | 148033 | None | code13 | Concealed Conduit System Supplying heavy PVC condiuit pipe ……mm dia ......mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/1.2.1) 19/20mm dia 2mm thick ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Mtr | 40.0 | 40.0 | 80.0 | False | None | None | False | None | False | 3200.0 | 0 | 3865072 | 148033 | None | code14 | Supplying heavy gauge PVC Conduit Pipe ….dia
…..mm thick with suitable size bends, metal junction boxes adhesive paste etx., by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Mtr | 51.0 | 51.0 | 80.0 | False | None | None | False | None | False | 4080.0 | 0 | 3865073 | 148033 | None | code15 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. 2.0 Sqm ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Mtr | 28.0 | 28.0 | 60.0 | False | None | None | False | None | False | 1680.0 | 0 | 3865074 | 148033 | None | code16 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. 2.5Sqm ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Mtr | 41.0 | 41.0 | 60.0 | False | None | None | False | None | False | 2460.0 | 0 | 3865075 | 148033 | None | code17 | Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulatedwires, required Nos of round blocks and clamps.On wall / ceiling / Rafter / Girders ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | No | 110.0 | 110.0 | 4.0 | False | None | None | False | None | False | 440.0 | 0 | 3865076 | 148033 | None | code18 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A, Short point upto 3Mtr from tapping point to out let via switch box ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | No | 210.0 | 210.0 | 2.0 | False | None | None | False | None | False | 420.0 | 0 | 3865077 | 148033 | None | code19 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Each | 241.5 | 241.5 | 3.0 | False | None | None | False | None | False | 724.5 | 0 |
|