createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1724736589184
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd21000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-09-2024 16:00:00
tenderQueryClose10-09-2024 16:00:00
technicalBidOpenNone
publishedDate27-08-2024 17:11:16
publishedByPostRDPR_EE_DIV_GAD
publishedByUserKPE16679 - VIJAYKUMAR MADIVALAPPA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHRI M P MANJUNATH
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08372238035
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1724736589227
version5
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT7980
titleCONSTRUCTION OF ADDL ROOM , TOILET SLAB REPAIR PRE- METRIC BOYS HOSTEL PARIVARTITA IN GADAG BCWD532 UNDER 2024-25 2225-00-103-0-40 Head
descriptionCONSTRUCTION OF ADDL ROOM , TOILET SLAB REPAIR PRE- METRIC BOYS HOSTEL PARIVARTITA IN GADAG BCWD532 UNDER 2024-25 2225-00-103-0-40 Head
categoryWORKS
categoryTextWorks
ecv839459.95
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location845
locationNameRDPR Division Office Gadag
provisionalAmount1000000.0
groupOverheadTotal0.0
fileNumber7980
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17247365890001NoneNoneBuildingsCONSTRUCTION OF ADDL ROOM , TOILET SLAB REPAIR PRE- METRIC BOYS HOSTEL PARIVARTITA IN GADAG BCWD532 UNDER 2225-00-103-0-40, YEAR2024-25814866.95
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3860972147791Nonecode1.4Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m (KPWD SR 23-24 Vol-I, P.No. 5, I.No. 1.4.) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum249.26249.2617.62FalseNoneNoneFalseNoneFalse4391.96120
3860973147791Nonecode2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (KPWD SR 23-24 Vol-I, P.No. 15, I.No. 2.1.3) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum6168.676168.673.96FalseNoneNoneFalseNoneFalse24427.93320
3860974147791Nonecode5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)( I.No. 5.2, page no.9,vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum6816.546816.549.97FalseNoneNoneFalseNoneFalse67960.90380
3860975147791Nonecode1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(KPWD SR 21-22 V-I Item ,page.no.7, No.1.9 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum273.98273.984.96FalseNoneNoneFalseNoneFalse1358.94080
3860976147791Nonecode3.6Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 (KPWD SR 21-22 Vol-III, P.No. 17, I.No. 3.6) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum507.79507.7912.58FalseNoneNoneFalseNoneFalse6387.99820
3860977147791Nonecode1.23Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as perspecifications.(KPWD SR 21-22 V-I Item,page.no.11 , No.1.23 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum2762.462762.462.52FalseNoneNoneFalseNoneFalse6961.39920
3860978147791Nonecode2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (I.No. 2.1.6, vol-I,P.no.15, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum10613.110613.13.89FalseNoneNoneFalseNoneFalse41284.9590
3860979147791Nonecode2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (I.No. 2.1.6, vol-I,P.no.15, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum10613.110613.111.6FalseNoneNoneFalseNoneFalse123111.960
3860980147791Nonecode2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (I.No. 2.11.a, vol-I, p.no.18, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workKgs92.1492.14870.0FalseNoneNoneFalseNoneFalse80161.80
3860981147791Nonecode6.1Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(I.No. 6.1, page no.13, vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum8466.68466.618.69FalseNoneNoneFalseNoneFalse158240.7540
3860982147791Nonecode8.4.1Providing 12mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement : 3 fine sand ) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete work as per specification and the direction of engineer incharge of work (I.No. 8.4.1, vol-II, page no.41,KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm332.69332.69203.6FalseNoneNoneFalseNoneFalse67735.6840
3860983147791Nonecode8.25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..( I.No.8.25, vol-II, page no.45,KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm141.11141.11208.62FalseNoneNoneFalseNoneFalse29438.36820
3860984147791Nonecode9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm(I.No. 9,22.2, Vol -II,page no.62, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm1365.781365.7827.25FalseNoneNoneFalseNoneFalse37217.5050
3860985147791Nonecode9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete..( I.No. 9.17.2 , vol-II, page no.61,KPWD SR 2023-24 )) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm1210.251210.251.0FalseNoneNoneFalseNoneFalse1210.250
3860986147791Nonecode9.34Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, including cost of materials, labour, curing, polishing complete as per specifications. I.No. 9.34, page no.64,vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm1591.351591.351.8FalseNoneNoneFalseNoneFalse2864.430
3860987147791Nonecode7.45.1Providing and laying non-asbestos high impact polypropylene reinforced corrugated cement roofing sheet reinforced with a blend of strong factory made fibers as per IS:14871 and ISO:9933:1995(E) roofing upto any pitch and fixing with polymer coated J or L hooks,bolts and nuts 8mm dia,G.I plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete but excluding the cost of purlins, rafters and trusses. Including cutting to size and shape of corrugated sheets wherever required.and cost of materials, labour, complete as per specifications. (I.No. 7.45.1, vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm728.21728.2130.0FalseNoneNoneFalseNoneFalse21846.30
3860988147791Nonecode12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specification ( I.No. 12.12, vol-II, page no.99,KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum127928.06127928.060.06FalseNoneNoneFalseNoneFalse7675.68360
3860989147791Nonecode12.21Providing and fixing in position Mathi/Nandi wood fully panelled shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specification (excluding cost of fixtures) ( I.No. 12.21, vol-II,page no.100, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm5914.265914.2615.06FalseNoneNoneFalseNoneFalse89068.75560
3860990147791Nonecode11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.( I.No. 11.34A, Vol -II, page no.86,KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workKgs173.04173.04100.8FalseNoneNoneFalseNoneFalse17442.4320
3860991147791Nonecode12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm6936.026936.023.24FalseNoneNoneFalseNoneFalse22472.70480
3860992147791Nonecode8.34.1,Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specification and as per the direction of engineer incharge of work(I.No. 8.34.1, Vol -II,page no.87, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm54.5954.5912.01FalseNoneNoneFalseNoneFalse655.62590
3860993147791Nonecode8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specification and as per the direction of engineer incharge of work (I.No. 8.41, Vol -II,page no.48, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm177.16177.1612.01FalseNoneNoneFalseNoneFalse2127.69160
3860994147791Nonecode13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreI.No. 13.5.3, Vol -II,page no.117, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workNo341.96341.962.0FalseNoneNoneFalseNoneFalse683.920
3860995147791Nonecode19.7.1Demolishing brick work manually/ by mechanical means including stack ing of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.( I.No. 12.21, vol-II,page no.187, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum496.46496.460.28FalseNoneNoneFalseNoneFalse139.00880
17247365890001NoneNoneBuildingsCONSTRUCTION OF ADDL ROOM , TOILET SLAB REPAIR PRE- METRIC BOYS HOSTEL PARIVARTITA IN GADAG BCWD532 UNDER 2225-00-103-0-40, YEAR2024-2524593.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3860996147792Nonecode1Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workMtr75.075.030.0FalseNoneNoneFalseNoneFalse2250.00
3860997147792Nonecode2Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workMtr80.080.030.0FalseNoneNoneFalseNoneFalse2400.00
3860998147792Nonecode3Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely25mm ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workMtr31.031.010.0FalseNoneNoneFalseNoneFalse310.00
3860999147792Nonecode4Point wiring using Copper wire with out switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm (Phase&Neutral) &1x1.0 Sqmm(earth Wire)Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto3mtr from tapping point to out let via Switch ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workPoint251.0251.010.0FalseNoneNoneFalseNoneFalse2510.00
3861000147792Nonecode6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,2.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.2023 ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workMtr40.040.020.0FalseNoneNoneFalseNoneFalse800.00
3861001147792Nonecode7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,4 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workMtr59.059.020.0FalseNoneNoneFalseNoneFalse1180.00
3861002147792Nonecode8Supplying and flush mounting powder coated / galvanized metal box size 1-3way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach123.0123.05.0FalseNoneNoneFalseNoneFalse615.00
3861003147792Nonecode9Supplying and flush mounting powder coated / galvanized metal box size 8way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach212.0212.05.0FalseNoneNoneFalseNoneFalse1060.00
3861004147792Nonecode10Supplying and flush mounting powder coated / galvanized metal box size10-12way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach325.0325.05.0FalseNoneNoneFalseNoneFalse1625.00
3861005147792Nonecode11Supplying and fixing superior quality 3Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach152.0152.05.0FalseNoneNoneFalseNoneFalse760.00
3861006147792Nonecode12Supplying and fixing superior quality 4Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach175.0175.05.0FalseNoneNoneFalseNoneFalse875.00
3861007147792Nonecode13Supplying and fixing superior quality 8 modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach302.0302.03.0FalseNoneNoneFalseNoneFalse906.00
3861008147792Nonecode14Supplying and fixing superior quality 10-12Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach363.0363.03.0FalseNoneNoneFalseNoneFalse1089.00
3861009147792Nonecode15Supplying and fixing of 6Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach88.088.05.0FalseNoneNoneFalseNoneFalse440.00
3861010147792Nonecode16Supplying and fixing of 6Amps 3way modular Socketc on existing modular switch plate as per IS 3854 and IS 1293. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach162.0162.04.0FalseNoneNoneFalseNoneFalse648.00
3861011147792Nonecode17Supplying and fixingof 6to32 Amps Double pole miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach1103.01103.01.0FalseNoneNoneFalseNoneFalse1103.00
3861012147792Nonecode18Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Economy model ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach2085.02085.02.0FalseNoneNoneFalseNoneFalse4170.00
3861013147792Nonecode19Supplying and fixing of of 9watts LED Bulbs. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach160.0160.04.0FalseNoneNoneFalseNoneFalse640.00
3861014147792Nonecode20Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach281.0281.02.0FalseNoneNoneFalseNoneFalse562.00
3861015147792Nonecode5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,1.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workMtr26.026.025.0FalseNoneNoneFalseNoneFalse650.00
17247371980000NoneNoneBuildingsCONSTRUCTION OF ADDL ROOM , TOILET SLAB REPAIR PRE- METRIC BOYS HOSTEL PARIVARTITA IN GADAG BCWD532 UNDER 2024-25 2225-00-103-0-40 Head839459.95
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3861225147799Nonecode1.4Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m (KPWD SR 23-24 Vol-I, P.No. 5, I.No. 1.4.) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum249.26249.2617.62FalseNoneNoneFalseNoneFalse4391.96120
3861249147799Nonecode1Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workMtr75.075.030.0FalseNoneNoneFalseNoneFalse2250.00
3861226147799Nonecode2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (KPWD SR 23-24 Vol-I, P.No. 15, I.No. 2.1.3) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum6168.676168.673.96FalseNoneNoneFalseNoneFalse24427.93320
3861250147799Nonecode2Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workMtr80.080.030.0FalseNoneNoneFalseNoneFalse2400.00
3861227147799Nonecode5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)( I.No. 5.2, page no.9,vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum6816.546816.549.97FalseNoneNoneFalseNoneFalse67960.90380
3861251147799Nonecode3Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely25mm ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workMtr31.031.010.0FalseNoneNoneFalseNoneFalse310.00
3861228147799Nonecode1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(KPWD SR 21-22 V-I Item ,page.no.7, No.1.9 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum273.98273.984.96FalseNoneNoneFalseNoneFalse1358.94080
3861252147799Nonecode4Point wiring using Copper wire with out switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm (Phase&Neutral) &1x1.0 Sqmm(earth Wire)Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto3mtr from tapping point to out let via Switch ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workPoint251.0251.010.0FalseNoneNoneFalseNoneFalse2510.00
3861253147799Nonecode6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,2.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.2023 ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workMtr40.040.020.0FalseNoneNoneFalseNoneFalse800.00
3861229147799Nonecode3.6Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 (KPWD SR 21-22 Vol-III, P.No. 17, I.No. 3.6) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum507.79507.7912.58FalseNoneNoneFalseNoneFalse6387.99820
3861230147799Nonecode1.23Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as perspecifications.(KPWD SR 21-22 V-I Item,page.no.11 , No.1.23 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum2762.462762.462.52FalseNoneNoneFalseNoneFalse6961.39920
3861254147799Nonecode7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,4 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workMtr59.059.020.0FalseNoneNoneFalseNoneFalse1180.00
3861231147799Nonecode2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (I.No. 2.1.6, vol-I,P.no.15, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum10613.110613.13.89FalseNoneNoneFalseNoneFalse41284.9590
3861255147799Nonecode8Supplying and flush mounting powder coated / galvanized metal box size 1-3way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach123.0123.05.0FalseNoneNoneFalseNoneFalse615.00
3861256147799Nonecode9Supplying and flush mounting powder coated / galvanized metal box size 8way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach212.0212.05.0FalseNoneNoneFalseNoneFalse1060.00
3861232147799Nonecode2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (I.No. 2.1.6, vol-I,P.no.15, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum10613.110613.111.6FalseNoneNoneFalseNoneFalse123111.960
3861233147799Nonecode2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (I.No. 2.11.a, vol-I, p.no.18, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workKgs92.1492.14870.0FalseNoneNoneFalseNoneFalse80161.80
3861257147799Nonecode10Supplying and flush mounting powder coated / galvanized metal box size10-12way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach325.0325.05.0FalseNoneNoneFalseNoneFalse1625.00
3861258147799Nonecode11Supplying and fixing superior quality 3Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach152.0152.05.0FalseNoneNoneFalseNoneFalse760.00
3861234147799Nonecode6.1Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(I.No. 6.1, page no.13, vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum8466.68466.618.69FalseNoneNoneFalseNoneFalse158240.7540
3861235147799Nonecode8.4.1Providing 12mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement : 3 fine sand ) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete work as per specification and the direction of engineer incharge of work (I.No. 8.4.1, vol-II, page no.41,KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm332.69332.69203.6FalseNoneNoneFalseNoneFalse67735.6840
3861259147799Nonecode12Supplying and fixing superior quality 4Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach175.0175.05.0FalseNoneNoneFalseNoneFalse875.00
3861260147799Nonecode13Supplying and fixing superior quality 8 modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach302.0302.03.0FalseNoneNoneFalseNoneFalse906.00
3861236147799Nonecode8.25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..( I.No.8.25, vol-II, page no.45,KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm141.11141.11208.62FalseNoneNoneFalseNoneFalse29438.36820
3861237147799Nonecode9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm(I.No. 9,22.2, Vol -II,page no.62, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm1365.781365.7827.25FalseNoneNoneFalseNoneFalse37217.5050
3861261147799Nonecode14Supplying and fixing superior quality 10-12Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach363.0363.03.0FalseNoneNoneFalseNoneFalse1089.00
3861262147799Nonecode15Supplying and fixing of 6Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach88.088.05.0FalseNoneNoneFalseNoneFalse440.00
3861238147799Nonecode9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete..( I.No. 9.17.2 , vol-II, page no.61,KPWD SR 2023-24 )) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm1210.251210.251.0FalseNoneNoneFalseNoneFalse1210.250
3861263147799Nonecode16Supplying and fixing of 6Amps 3way modular Socketc on existing modular switch plate as per IS 3854 and IS 1293. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach162.0162.04.0FalseNoneNoneFalseNoneFalse648.00
3861239147799Nonecode9.34Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, including cost of materials, labour, curing, polishing complete as per specifications. I.No. 9.34, page no.64,vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm1591.351591.351.8FalseNoneNoneFalseNoneFalse2864.430
3861240147799Nonecode7.45.1Providing and laying non-asbestos high impact polypropylene reinforced corrugated cement roofing sheet reinforced with a blend of strong factory made fibers as per IS:14871 and ISO:9933:1995(E) roofing upto any pitch and fixing with polymer coated J or L hooks,bolts and nuts 8mm dia,G.I plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete but excluding the cost of purlins, rafters and trusses. Including cutting to size and shape of corrugated sheets wherever required.and cost of materials, labour, complete as per specifications. (I.No. 7.45.1, vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm728.21728.2130.0FalseNoneNoneFalseNoneFalse21846.30
3861264147799Nonecode17Supplying and fixingof 6to32 Amps Double pole miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach1103.01103.01.0FalseNoneNoneFalseNoneFalse1103.00
3861241147799Nonecode12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specification ( I.No. 12.12, vol-II, page no.99,KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum127928.06127928.060.06FalseNoneNoneFalseNoneFalse7675.68360
3861265147799Nonecode18Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Economy model ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach2085.02085.02.0FalseNoneNoneFalseNoneFalse4170.00
3861242147799Nonecode12.21Providing and fixing in position Mathi/Nandi wood fully panelled shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specification (excluding cost of fixtures) ( I.No. 12.21, vol-II,page no.100, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm5914.265914.2615.06FalseNoneNoneFalseNoneFalse89068.75560
3861266147799Nonecode19Supplying and fixing of of 9watts LED Bulbs. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach160.0160.04.0FalseNoneNoneFalseNoneFalse640.00
3861243147799Nonecode11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.( I.No. 11.34A, Vol -II, page no.86,KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workKgs173.04173.04100.8FalseNoneNoneFalseNoneFalse17442.4320
3861267147799Nonecode20Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workEach281.0281.02.0FalseNoneNoneFalseNoneFalse562.00
3861268147799Nonecode5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,1.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workMtr26.026.025.0FalseNoneNoneFalseNoneFalse650.00
3861244147799Nonecode12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm6936.026936.023.24FalseNoneNoneFalseNoneFalse22472.70480
3861245147799Nonecode8.34.1,Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specification and as per the direction of engineer incharge of work(I.No. 8.34.1, Vol -II,page no.87, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm54.5954.5912.01FalseNoneNoneFalseNoneFalse655.62590
3861246147799Nonecode8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specification and as per the direction of engineer incharge of work (I.No. 8.41, Vol -II,page no.48, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workSqm177.16177.1612.01FalseNoneNoneFalseNoneFalse2127.69160
3861247147799Nonecode13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreI.No. 13.5.3, Vol -II,page no.117, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workNo341.96341.962.0FalseNoneNoneFalseNoneFalse683.920
3861248147799Nonecode19.7.1Demolishing brick work manually/ by mechanical means including stack ing of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.( I.No. 12.21, vol-II,page no.187, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the workCum496.46496.460.28FalseNoneNoneFalseNoneFalse139.00880
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17247365900001NoneNoneELIGIBILITYLine of credit 30% to APT amount that is not less than Rupees- lakhs (Conditional LOC not considered)None
17247365900000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17247365900001NoneNoneELIGIBILITYThe tender is through e mode onlyNone
17247365900000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17247365900000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17247365900000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17247365900001NoneNoneELIGIBILITYThe rates enumerated in the tender schedule / BOQ are inclusive of all lead and lifts and all other charges to complete the work successfully.None
17247365900001NoneNoneELIGIBILITYThe tender may be cancelled at any stage without assigning any reasonNone
17247365900001NoneNoneELIGIBILITYTenderer must submit his present accurate postal address and phone / cell phone numberNone
17247365900001NoneNoneELIGIBILITYMaterials to be utilized for the work must be tested in PRED labs and quality control test reports must be enclosed to the bills. Cost of quality control tests must be borne by the contractorNone
17247367510000NoneNoneELIGIBILITYTenderer who is successful in any tender previously, but not submitted security deposit, is not eligible to participate in this tenderNone
17247367600000NoneNoneELIGIBILITYIf any date in tender time table is government holiday, next working day will be consideredNone
17247367680000NoneNoneELIGIBILITYExecutive Engineer PRED Gadag has authority to reject or accept any tender without assigning any reasonNone
17247367770000NoneNoneELIGIBILITYIf the rates Quoted by the contractor is lesser than the amount put to tender, the difference cost should be paid by the contractor through DD/ FDR / NSC in the favour of Executive Engineer. within 20 days of the receipt of the letter of acceptance for unbalanced tenders in accordance with clause 25.5 of ITT and clause 44 of the condition of contract as per G.O.No FD 94 PCL 2008 Bangalore dated 14.10.2008None
17247367860000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separatelyNone
17247367950000NoneNoneELIGIBILITYThe contractor should provide daily there staff members on siteNone
17247368030000NoneNoneELIGIBILITYIf there is any objection regarding tender, eligibility of contractors, documents etc. The objection must be submitted before last date & time of submission of tender directly to Executive Engineer, PRE Dn, Gadag. (Not in inwardNone
17247368160000NoneNoneELIGIBILITYThe work subjected to third party inspection and inspection by other govt agencies third party inspection cost is borne by the contractor for the gross amount of the bill third party agency is appointed by the deptNone
17247368260000NoneNoneELIGIBILITYAspiring bidders/ contractors who have not obtained the user ID & Password for participating in E-Proc in PRED may now obtain the same from the website www.kppp.karnataka.gov.in through linkNone
17247368370000NoneNoneELIGIBILITYCorrigendum/modifications/corrections, if any, will be published only in the website individual letters, information to bidders will not be sent by post, courier. All information will be on the web site. However in case of any clarification required you are directed to contact the under signed during office hours on all working daysNone
17247368460000NoneNoneELIGIBILITYIf any of the dates mentioned above is declared as holiday, the next working day will hold good without any change in the timings indicatedNone
17247368560000NoneNoneELIGIBILITYFurther details of work can be obtained in the office of the undersigned all working daysNone
17247368640000NoneNoneELIGIBILITYTenderer can inspect site before quoting rates. Quoted rates are inclusive statutory deduction as per Government orderNone
17247368720000NoneNoneELIGIBILITYAny over writing of civil engineering words and measurements should be clarified the considered department ( No claims should be consideredNone
17247368840000NoneNoneELIGIBILITYWork Completion/Execution Period : 06 MonthsNone
17247368950000NoneNoneELIGIBILITYContractor should upload PWD Valid Registration copyNone
17247369360000NoneNoneELIGIBILITYSimilar wok done 50% OTH & 25% SC ST attached separate sheet should not be less than Rs. lks.None
17247369440000NoneNoneELIGIBILITYWithin 20 days of receipt of the Letter of Acceptance, the successful Tenderer shall deliver to the Employer a Security deposit(FDR) for an amount equivalent to 5% of the Contract priceNone
17247369540000NoneNoneELIGIBILITYWork done certificate should be issued by competent authority not below the rank of Executive Engineer.None
17247369650000NoneNoneELIGIBILITYThe tender of any tenderer who does not accept the conditions contained in the tender document is liable to be rejected. Conditional tenders will not be acceptedNone
17247369740000NoneNoneELIGIBILITYThe cost of tender form fee shall not be refundable. The tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs. No interest will be paid by the Government on the Earnest money depositNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover certificate CA with UDIN No. & Profit and loss statements & Income Tax returnsTrueTechnical Bid
PWD Valid Registration CertificateTrueTechnical Bid
Line of credit amount that is not less than Rupees- lakhs, Conditional LOC not consideredTrueTechnical Bid
50percent Similar work done BUILDING ,CC DRAIN, ROAD WORK attached separate sheet should not be less than Rs. lksTrueTechnical Bid
Postal Address with contact numberTrueTechnical Bid
PAN & GST CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone