tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1724736589000 | 1 | None | None | Buildings | CONSTRUCTION OF ADDL ROOM , TOILET SLAB REPAIR PRE- METRIC BOYS HOSTEL PARIVARTITA IN GADAG BCWD532 UNDER 2225-00-103-0-40, YEAR2024-25 | 814866.95 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3860972 | 147791 | None | code1.4 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
(KPWD SR 23-24 Vol-I, P.No. 5, I.No. 1.4.) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 249.26 | 249.26 | 17.62 | False | None | None | False | None | False | 4391.9612 | 0 | 3860973 | 147791 | None | code2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)
Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
(KPWD SR 23-24 Vol-I, P.No. 15, I.No. 2.1.3) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 6168.67 | 6168.67 | 3.96 | False | None | None | False | None | False | 24427.9332 | 0 | 3860974 | 147791 | None | code5.2 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)( I.No. 5.2, page no.9,vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 6816.54 | 6816.54 | 9.97 | False | None | None | False | None | False | 67960.9038 | 0 | 3860975 | 147791 | None | code1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(KPWD SR 21-22 V-I Item ,page.no.7, No.1.9 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 273.98 | 273.98 | 4.96 | False | None | None | False | None | False | 1358.9408 | 0 | 3860976 | 147791 | None | code3.6 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2
(KPWD SR 21-22 Vol-III, P.No. 17, I.No. 3.6) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 507.79 | 507.79 | 12.58 | False | None | None | False | None | False | 6387.9982 | 0 | 3860977 | 147791 | None | code1.23 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as perspecifications.(KPWD SR 21-22 V-I Item,page.no.11 , No.1.23 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 2762.46 | 2762.46 | 2.52 | False | None | None | False | None | False | 6961.3992 | 0 | 3860978 | 147791 | None | code2.1.6 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (I.No. 2.1.6, vol-I,P.no.15, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 10613.1 | 10613.1 | 3.89 | False | None | None | False | None | False | 41284.959 | 0 | 3860979 | 147791 | None | code2.1.6 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (I.No. 2.1.6, vol-I,P.no.15, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 10613.1 | 10613.1 | 11.6 | False | None | None | False | None | False | 123111.96 | 0 | 3860980 | 147791 | None | code2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (I.No. 2.11.a, vol-I, p.no.18, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Kgs | 92.14 | 92.14 | 870.0 | False | None | None | False | None | False | 80161.8 | 0 | 3860981 | 147791 | None | code6.1 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(I.No. 6.1, page no.13, vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 8466.6 | 8466.6 | 18.69 | False | None | None | False | None | False | 158240.754 | 0 | 3860982 | 147791 | None | code8.4.1 | Providing 12mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement : 3 fine sand ) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete work as per specification and the direction of engineer incharge of work (I.No. 8.4.1, vol-II, page no.41,KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 332.69 | 332.69 | 203.6 | False | None | None | False | None | False | 67735.684 | 0 | 3860983 | 147791 | None | code8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..( I.No.8.25, vol-II, page no.45,KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 141.11 | 141.11 | 208.62 | False | None | None | False | None | False | 29438.3682 | 0 | 3860984 | 147791 | None | code9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm(I.No. 9,22.2, Vol -II,page no.62, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 1365.78 | 1365.78 | 27.25 | False | None | None | False | None | False | 37217.505 | 0 | 3860985 | 147791 | None | code9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete..( I.No. 9.17.2 , vol-II, page no.61,KPWD SR 2023-24 )) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 1210.25 | 1210.25 | 1.0 | False | None | None | False | None | False | 1210.25 | 0 | 3860986 | 147791 | None | code9.34 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, including cost of materials, labour, curing, polishing complete as per specifications. I.No. 9.34, page no.64,vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 1591.35 | 1591.35 | 1.8 | False | None | None | False | None | False | 2864.43 | 0 | 3860987 | 147791 | None | code7.45.1 | Providing and laying non-asbestos high impact polypropylene reinforced corrugated cement roofing sheet reinforced with a blend of strong factory made fibers as per IS:14871 and ISO:9933:1995(E) roofing upto any pitch and fixing with polymer coated J or L hooks,bolts and nuts 8mm dia,G.I plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete but excluding the cost of purlins, rafters and trusses. Including cutting to size and shape of corrugated sheets wherever required.and cost of materials, labour, complete as per specifications. (I.No. 7.45.1, vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 728.21 | 728.21 | 30.0 | False | None | None | False | None | False | 21846.3 | 0 | 3860988 | 147791 | None | code12.12 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specification ( I.No. 12.12, vol-II, page no.99,KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 127928.06 | 127928.06 | 0.06 | False | None | None | False | None | False | 7675.6836 | 0 | 3860989 | 147791 | None | code12.21 | Providing and fixing in position Mathi/Nandi wood fully panelled shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specification (excluding cost of fixtures) ( I.No. 12.21, vol-II,page no.100, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 5914.26 | 5914.26 | 15.06 | False | None | None | False | None | False | 89068.7556 | 0 | 3860990 | 147791 | None | code11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.( I.No. 11.34A, Vol -II, page no.86,KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Kgs | 173.04 | 173.04 | 100.8 | False | None | None | False | None | False | 17442.432 | 0 | 3860991 | 147791 | None | code12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 6936.02 | 6936.02 | 3.24 | False | None | None | False | None | False | 22472.7048 | 0 | 3860992 | 147791 | None | code8.34.1, | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specification and as per the direction of engineer incharge of work(I.No. 8.34.1, Vol -II,page no.87, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 54.59 | 54.59 | 12.01 | False | None | None | False | None | False | 655.6259 | 0 | 3860993 | 147791 | None | code8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specification and as per the direction of engineer incharge of work (I.No. 8.41, Vol -II,page no.48, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 177.16 | 177.16 | 12.01 | False | None | None | False | None | False | 2127.6916 | 0 | 3860994 | 147791 | None | code13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreI.No. 13.5.3, Vol -II,page no.117, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | No | 341.96 | 341.96 | 2.0 | False | None | None | False | None | False | 683.92 | 0 | 3860995 | 147791 | None | code19.7.1 | Demolishing brick work manually/ by mechanical means including stack ing of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.( I.No. 12.21, vol-II,page no.187, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 496.46 | 496.46 | 0.28 | False | None | None | False | None | False | 139.0088 | 0 |
| 1724736589000 | 1 | None | None | Buildings | CONSTRUCTION OF ADDL ROOM , TOILET SLAB REPAIR PRE- METRIC BOYS HOSTEL PARIVARTITA IN GADAG BCWD532 UNDER 2225-00-103-0-40, YEAR2024-25 | 24593.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3860996 | 147792 | None | code1 | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Mtr | 75.0 | 75.0 | 30.0 | False | None | None | False | None | False | 2250.0 | 0 | 3860997 | 147792 | None | code2 | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Mtr | 80.0 | 80.0 | 30.0 | False | None | None | False | None | False | 2400.0 | 0 | 3860998 | 147792 | None | code3 | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely25mm ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Mtr | 31.0 | 31.0 | 10.0 | False | None | None | False | None | False | 310.0 | 0 | 3860999 | 147792 | None | code4 | Point wiring using Copper wire with out switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm (Phase&Neutral) &1x1.0 Sqmm(earth Wire)Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto3mtr from tapping point to out let via Switch ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Point | 251.0 | 251.0 | 10.0 | False | None | None | False | None | False | 2510.0 | 0 | 3861000 | 147792 | None | code6 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,2.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.2023 ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Mtr | 40.0 | 40.0 | 20.0 | False | None | None | False | None | False | 800.0 | 0 | 3861001 | 147792 | None | code7 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,4 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Mtr | 59.0 | 59.0 | 20.0 | False | None | None | False | None | False | 1180.0 | 0 | 3861002 | 147792 | None | code8 | Supplying and flush mounting powder coated / galvanized metal box size 1-3way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 123.0 | 123.0 | 5.0 | False | None | None | False | None | False | 615.0 | 0 | 3861003 | 147792 | None | code9 | Supplying and flush mounting powder coated / galvanized metal box size 8way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 212.0 | 212.0 | 5.0 | False | None | None | False | None | False | 1060.0 | 0 | 3861004 | 147792 | None | code10 | Supplying and flush mounting powder coated / galvanized metal box size10-12way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 325.0 | 325.0 | 5.0 | False | None | None | False | None | False | 1625.0 | 0 | 3861005 | 147792 | None | code11 | Supplying and fixing superior quality 3Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 152.0 | 152.0 | 5.0 | False | None | None | False | None | False | 760.0 | 0 | 3861006 | 147792 | None | code12 | Supplying and fixing superior quality 4Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 175.0 | 175.0 | 5.0 | False | None | None | False | None | False | 875.0 | 0 | 3861007 | 147792 | None | code13 | Supplying and fixing superior quality 8 modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 302.0 | 302.0 | 3.0 | False | None | None | False | None | False | 906.0 | 0 | 3861008 | 147792 | None | code14 | Supplying and fixing superior quality 10-12Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 363.0 | 363.0 | 3.0 | False | None | None | False | None | False | 1089.0 | 0 | 3861009 | 147792 | None | code15 | Supplying and fixing of 6Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 88.0 | 88.0 | 5.0 | False | None | None | False | None | False | 440.0 | 0 | 3861010 | 147792 | None | code16 | Supplying and fixing of 6Amps 3way modular Socketc on existing modular switch plate as per IS 3854 and IS 1293. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 162.0 | 162.0 | 4.0 | False | None | None | False | None | False | 648.0 | 0 | 3861011 | 147792 | None | code17 | Supplying and fixingof 6to32 Amps Double pole miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 1103.0 | 1103.0 | 1.0 | False | None | None | False | None | False | 1103.0 | 0 | 3861012 | 147792 | None | code18 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Economy model ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 2085.0 | 2085.0 | 2.0 | False | None | None | False | None | False | 4170.0 | 0 | 3861013 | 147792 | None | code19 | Supplying and fixing of of 9watts LED Bulbs. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 160.0 | 160.0 | 4.0 | False | None | None | False | None | False | 640.0 | 0 | 3861014 | 147792 | None | code20 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 281.0 | 281.0 | 2.0 | False | None | None | False | None | False | 562.0 | 0 | 3861015 | 147792 | None | code5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,1.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Mtr | 26.0 | 26.0 | 25.0 | False | None | None | False | None | False | 650.0 | 0 |
| 1724737198000 | 0 | None | None | Buildings | CONSTRUCTION OF ADDL ROOM , TOILET SLAB REPAIR PRE- METRIC BOYS HOSTEL PARIVARTITA IN GADAG BCWD532 UNDER 2024-25 2225-00-103-0-40 Head | 839459.95 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3861225 | 147799 | None | code1.4 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
(KPWD SR 23-24 Vol-I, P.No. 5, I.No. 1.4.) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 249.26 | 249.26 | 17.62 | False | None | None | False | None | False | 4391.9612 | 0 | 3861249 | 147799 | None | code1 | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Mtr | 75.0 | 75.0 | 30.0 | False | None | None | False | None | False | 2250.0 | 0 | 3861226 | 147799 | None | code2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)
Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
(KPWD SR 23-24 Vol-I, P.No. 15, I.No. 2.1.3) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 6168.67 | 6168.67 | 3.96 | False | None | None | False | None | False | 24427.9332 | 0 | 3861250 | 147799 | None | code2 | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Mtr | 80.0 | 80.0 | 30.0 | False | None | None | False | None | False | 2400.0 | 0 | 3861227 | 147799 | None | code5.2 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)( I.No. 5.2, page no.9,vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 6816.54 | 6816.54 | 9.97 | False | None | None | False | None | False | 67960.9038 | 0 | 3861251 | 147799 | None | code3 | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely25mm ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Mtr | 31.0 | 31.0 | 10.0 | False | None | None | False | None | False | 310.0 | 0 | 3861228 | 147799 | None | code1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(KPWD SR 21-22 V-I Item ,page.no.7, No.1.9 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 273.98 | 273.98 | 4.96 | False | None | None | False | None | False | 1358.9408 | 0 | 3861252 | 147799 | None | code4 | Point wiring using Copper wire with out switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm (Phase&Neutral) &1x1.0 Sqmm(earth Wire)Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto3mtr from tapping point to out let via Switch ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Point | 251.0 | 251.0 | 10.0 | False | None | None | False | None | False | 2510.0 | 0 | 3861253 | 147799 | None | code6 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,2.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.2023 ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Mtr | 40.0 | 40.0 | 20.0 | False | None | None | False | None | False | 800.0 | 0 | 3861229 | 147799 | None | code3.6 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2
(KPWD SR 21-22 Vol-III, P.No. 17, I.No. 3.6) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 507.79 | 507.79 | 12.58 | False | None | None | False | None | False | 6387.9982 | 0 | 3861230 | 147799 | None | code1.23 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as perspecifications.(KPWD SR 21-22 V-I Item,page.no.11 , No.1.23 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 2762.46 | 2762.46 | 2.52 | False | None | None | False | None | False | 6961.3992 | 0 | 3861254 | 147799 | None | code7 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,4 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Mtr | 59.0 | 59.0 | 20.0 | False | None | None | False | None | False | 1180.0 | 0 | 3861231 | 147799 | None | code2.1.6 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (I.No. 2.1.6, vol-I,P.no.15, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 10613.1 | 10613.1 | 3.89 | False | None | None | False | None | False | 41284.959 | 0 | 3861255 | 147799 | None | code8 | Supplying and flush mounting powder coated / galvanized metal box size 1-3way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 123.0 | 123.0 | 5.0 | False | None | None | False | None | False | 615.0 | 0 | 3861256 | 147799 | None | code9 | Supplying and flush mounting powder coated / galvanized metal box size 8way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 212.0 | 212.0 | 5.0 | False | None | None | False | None | False | 1060.0 | 0 | 3861232 | 147799 | None | code2.1.6 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (I.No. 2.1.6, vol-I,P.no.15, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 10613.1 | 10613.1 | 11.6 | False | None | None | False | None | False | 123111.96 | 0 | 3861233 | 147799 | None | code2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (I.No. 2.11.a, vol-I, p.no.18, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Kgs | 92.14 | 92.14 | 870.0 | False | None | None | False | None | False | 80161.8 | 0 | 3861257 | 147799 | None | code10 | Supplying and flush mounting powder coated / galvanized metal box size10-12way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 325.0 | 325.0 | 5.0 | False | None | None | False | None | False | 1625.0 | 0 | 3861258 | 147799 | None | code11 | Supplying and fixing superior quality 3Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 152.0 | 152.0 | 5.0 | False | None | None | False | None | False | 760.0 | 0 | 3861234 | 147799 | None | code6.1 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(I.No. 6.1, page no.13, vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 8466.6 | 8466.6 | 18.69 | False | None | None | False | None | False | 158240.754 | 0 | 3861235 | 147799 | None | code8.4.1 | Providing 12mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement : 3 fine sand ) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete work as per specification and the direction of engineer incharge of work (I.No. 8.4.1, vol-II, page no.41,KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 332.69 | 332.69 | 203.6 | False | None | None | False | None | False | 67735.684 | 0 | 3861259 | 147799 | None | code12 | Supplying and fixing superior quality 4Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 175.0 | 175.0 | 5.0 | False | None | None | False | None | False | 875.0 | 0 | 3861260 | 147799 | None | code13 | Supplying and fixing superior quality 8 modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 302.0 | 302.0 | 3.0 | False | None | None | False | None | False | 906.0 | 0 | 3861236 | 147799 | None | code8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..( I.No.8.25, vol-II, page no.45,KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 141.11 | 141.11 | 208.62 | False | None | None | False | None | False | 29438.3682 | 0 | 3861237 | 147799 | None | code9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm(I.No. 9,22.2, Vol -II,page no.62, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 1365.78 | 1365.78 | 27.25 | False | None | None | False | None | False | 37217.505 | 0 | 3861261 | 147799 | None | code14 | Supplying and fixing superior quality 10-12Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 363.0 | 363.0 | 3.0 | False | None | None | False | None | False | 1089.0 | 0 | 3861262 | 147799 | None | code15 | Supplying and fixing of 6Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 88.0 | 88.0 | 5.0 | False | None | None | False | None | False | 440.0 | 0 | 3861238 | 147799 | None | code9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete..( I.No. 9.17.2 , vol-II, page no.61,KPWD SR 2023-24 )) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 1210.25 | 1210.25 | 1.0 | False | None | None | False | None | False | 1210.25 | 0 | 3861263 | 147799 | None | code16 | Supplying and fixing of 6Amps 3way modular Socketc on existing modular switch plate as per IS 3854 and IS 1293. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 162.0 | 162.0 | 4.0 | False | None | None | False | None | False | 648.0 | 0 | 3861239 | 147799 | None | code9.34 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, including cost of materials, labour, curing, polishing complete as per specifications. I.No. 9.34, page no.64,vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 1591.35 | 1591.35 | 1.8 | False | None | None | False | None | False | 2864.43 | 0 | 3861240 | 147799 | None | code7.45.1 | Providing and laying non-asbestos high impact polypropylene reinforced corrugated cement roofing sheet reinforced with a blend of strong factory made fibers as per IS:14871 and ISO:9933:1995(E) roofing upto any pitch and fixing with polymer coated J or L hooks,bolts and nuts 8mm dia,G.I plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete but excluding the cost of purlins, rafters and trusses. Including cutting to size and shape of corrugated sheets wherever required.and cost of materials, labour, complete as per specifications. (I.No. 7.45.1, vol-II, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 728.21 | 728.21 | 30.0 | False | None | None | False | None | False | 21846.3 | 0 | 3861264 | 147799 | None | code17 | Supplying and fixingof 6to32 Amps Double pole miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 1103.0 | 1103.0 | 1.0 | False | None | None | False | None | False | 1103.0 | 0 | 3861241 | 147799 | None | code12.12 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specification ( I.No. 12.12, vol-II, page no.99,KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 127928.06 | 127928.06 | 0.06 | False | None | None | False | None | False | 7675.6836 | 0 | 3861265 | 147799 | None | code18 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Economy model ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 2085.0 | 2085.0 | 2.0 | False | None | None | False | None | False | 4170.0 | 0 | 3861242 | 147799 | None | code12.21 | Providing and fixing in position Mathi/Nandi wood fully panelled shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specification (excluding cost of fixtures) ( I.No. 12.21, vol-II,page no.100, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 5914.26 | 5914.26 | 15.06 | False | None | None | False | None | False | 89068.7556 | 0 | 3861266 | 147799 | None | code19 | Supplying and fixing of of 9watts LED Bulbs. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 160.0 | 160.0 | 4.0 | False | None | None | False | None | False | 640.0 | 0 | 3861243 | 147799 | None | code11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.( I.No. 11.34A, Vol -II, page no.86,KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Kgs | 173.04 | 173.04 | 100.8 | False | None | None | False | None | False | 17442.432 | 0 | 3861267 | 147799 | None | code20 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Each | 281.0 | 281.0 | 2.0 | False | None | None | False | None | False | 562.0 | 0 | 3861268 | 147799 | None | code5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,1.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Mtr | 26.0 | 26.0 | 25.0 | False | None | None | False | None | False | 650.0 | 0 | 3861244 | 147799 | None | code12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 6936.02 | 6936.02 | 3.24 | False | None | None | False | None | False | 22472.7048 | 0 | 3861245 | 147799 | None | code8.34.1, | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specification and as per the direction of engineer incharge of work(I.No. 8.34.1, Vol -II,page no.87, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 54.59 | 54.59 | 12.01 | False | None | None | False | None | False | 655.6259 | 0 | 3861246 | 147799 | None | code8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specification and as per the direction of engineer incharge of work (I.No. 8.41, Vol -II,page no.48, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 177.16 | 177.16 | 12.01 | False | None | None | False | None | False | 2127.6916 | 0 | 3861247 | 147799 | None | code13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreI.No. 13.5.3, Vol -II,page no.117, KPWD SR 2023-24) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | No | 341.96 | 341.96 | 2.0 | False | None | None | False | None | False | 683.92 | 0 | 3861248 | 147799 | None | code19.7.1 | Demolishing brick work manually/ by mechanical means including stack ing of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.( I.No. 12.21, vol-II,page no.187, KPWD SR 2023-24 ) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 496.46 | 496.46 | 0.28 | False | None | None | False | None | False | 139.0088 | 0 |
|
|
---|