3861468 | 147806 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 102.0 | 102.0 | 11.72 | False | None | None | False | None | False | 1195.44 | 0 |
3861469 | 147806 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates. with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 5664.0 | 5664.0 | 1.173 | False | None | None | False | None | False | 6643.872 | 0 |
3861470 | 147806 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 5611.0 | 5611.0 | 5.2514 | False | None | None | False | None | False | 29465.6054 | 0 |
3861471 | 147806 | None | code04 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 6389.0 | 6389.0 | 9.524 | False | None | None | False | None | False | 60848.836 | 0 |
3861472 | 147806 | None | code05 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 433.0 | 433.0 | 36.24 | False | None | None | False | None | False | 15691.92 | 0 |
3861473 | 147806 | None | code06 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 5989.0 | 5989.0 | 3.883 | False | None | None | False | None | False | 23255.287 | 0 |
3861474 | 147806 | None | code07 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 9613.5 | 9613.5 | 1.431 | False | None | None | False | None | False | 13756.9185 | 0 |
3861475 | 147806 | None | code08 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Tonne | 89457.0 | 89457.0 | 0.1 | False | None | None | False | None | False | 8945.7 | 0 |
3861476 | 147806 | None | code09 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Cum | 7969.0 | 7969.0 | 23.792 | False | None | None | False | None | False | 189598.448 | 0 |
3861477 | 147806 | None | code10 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Sqm | 4043.0 | 4043.0 | 5.04 | False | None | None | False | None | False | 20376.72 | 0 |
3861478 | 147806 | None | code11 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Kg | 168.0 | 168.0 | 454.56 | False | None | None | False | None | False | 76366.08 | 0 |
3861479 | 147806 | None | code12 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Sqm | 1171.0 | 1171.0 | 14.4 | False | None | None | False | None | False | 16862.4 | 0 |
3861480 | 147806 | None | code13 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.. with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Sqm | 1175.0 | 1175.0 | 102.5 | False | None | None | False | None | False | 120437.5 | 0 |
3861481 | 147806 | None | code14 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work.. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Sqm | 1392.0 | 1392.0 | 70.902 | False | None | None | False | None | False | 98695.584 | 0 |
3861482 | 147806 | None | code15 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Sqm | 354.0 | 354.0 | 32.69 | False | None | None | False | None | False | 11572.26 | 0 |
3861483 | 147806 | None | code16 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Sqm | 295.0 | 295.0 | 266.04 | False | None | None | False | None | False | 78481.8 | 0 |
3861484 | 147806 | None | code17 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Sqm | 100.0 | 100.0 | 53.83 | False | None | None | False | None | False | 5383.0 | 0 |
3861485 | 147806 | None | code18 | Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Sqm | 108.0 | 108.0 | 53.83 | False | None | None | False | None | False | 5813.64 | 0 |
3861486 | 147806 | None | code19 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Sqm | 89.0 | 89.0 | 120.66 | False | None | None | False | None | False | 10738.74 | 0 |
3861487 | 147806 | None | code20 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Sqm | 138.0 | 138.0 | 11.34 | False | None | None | False | None | False | 1564.92 | 0 |
3861488 | 147806 | None | code21 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Wedge expansion type Fastener with threaded dia 6 mm with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Sqm | 49.0 | 49.0 | 6.0 | False | None | None | False | None | False | 294.0 | 0 |
3861489 | 147806 | None | code22 | uPVC Pipes 32 mm nominal dia.. with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Mtr | 101.0 | 101.0 | 35.0 | False | None | None | False | None | False | 3535.0 | 0 |
3861490 | 147806 | None | code23 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: . with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Each | 3082.0 | 3082.0 | 1.0 | False | None | None | False | None | False | 3082.0 | 0 |
3861491 | 147806 | None | code24 | Concealed Conduit System Supplying heavy PVC condiuit pipe ……mm dia ......mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/1.2.1) 19/20mm dia 2mm thick with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Mtr | 40.0 | 40.0 | 30.0 | False | None | None | False | None | False | 1200.0 | 0 |
3861492 | 147806 | None | code25 | Supplying heavy gauge PVC Conduit Pipe ….dia …..mm thick with suitable size bends, metal junction boxes adhesive paste etx., by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.( P-2,/1.3.1) 19/20mm dia 2mm thick with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Mtr | 51.0 | 51.0 | 30.0 | False | None | None | False | None | False | 1530.0 | 0 |
3861493 | 147806 | None | code26 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. (6/2.5.2) GTP of GROUP-a 1.5 sqmm with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. 25 Sqm ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Mtr | 28.0 | 28.0 | 35.0 | False | None | None | False | None | False | 980.0 | 0 |
3861494 | 147806 | None | code27 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. (6/2.5.2) GTP of GROUP-a 1.5 sqmm with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. 25 Sqm ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Mtr | 41.0 | 41.0 | 30.0 | False | None | None | False | None | False | 1230.0 | 0 |
3861495 | 147806 | None | code28 | Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulatedwires, required Nos of round blocks and clamps.On wall / ceiling / Rafter / Girders with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Mtr | 110.0 | 110.0 | 6.0 | False | None | None | False | None | False | 660.0 | 0 |
3861496 | 147806 | None | code29 | Supplying capacitor type celing fan complete with down road blades shakle regulator capacities., for operation on 230 volts 50 cycles single phase AC supply confirming to ISI 374-1979 and with double ball bearing system and as per technical approved (1200 mm swing) with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Mtr | 2949.0 | 2949.0 | 4.0 | False | None | None | False | None | False | 11796.0 | 0 |
3861497 | 147806 | None | code30 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | Ltr | 9.0 | 9.0 | 1000.0 | False | None | None | False | None | False | 9000.0 | 0 |
3861498 | 147806 | None | code31 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch)suitable for bore well confirming to IS 8034-2000 specifications, to worksite with testing of as per instructions of engineer incharge of work and latest amendments etc., complete with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work. | No | 10170.0 | 10170.0 | 1.0 | False | None | None | False | None | False | 10170.0 | 0 |