1724741357000 | 0 | None | None | Buildings | Construction of a new medicine storage room for primary health center, Installing new windows and doors, Construction of water tank for water storage of Huilagola village of Gadag taluk Gadag Dist Under 2024-25 2210-00-101-36 Head | 756204.25 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3862010 | 147840 | None | code12.12 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 124202.0 | 124202.0 | 0.19 | False | None | None | False | None | False | 23598.38 | 0 | 3862011 | 147840 | None | code12.15 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 6897.0 | 6897.0 | 20.0 | False | None | None | False | None | False | 137940.0 | 0 | 3862012 | 147840 | None | code.12.53 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 1588.0 | 1588.0 | 6.3 | False | None | None | False | None | False | 10004.4 | 0 | 3862013 | 147840 | None | code11.44 | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 4345.0 | 4345.0 | 26.13 | False | None | None | False | None | False | 113534.85 | 0 | 3862014 | 147840 | None | code6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 7969.0 | 7969.0 | 0.7 | False | None | None | False | None | False | 5578.3 | 0 | 3862015 | 147840 | None | code9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 2466.0 | 2466.0 | 28.35 | False | None | None | False | None | False | 69911.1 | 0 | 3862016 | 147840 | None | code13.31.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | m | 242.0 | 242.0 | 20.0 | False | None | None | False | None | False | 4840.0 | 0 | 3862017 | 147840 | None | code13.31.2 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work ,50 mm nominal dia Pipes ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | m | 386.0 | 386.0 | 20.0 | False | None | None | False | None | False | 7720.0 | 0 | 3862018 | 147840 | None | code19.13.1 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking to the appropriate disposal area as per direction of Engineer-in-charge. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 94.0 | 94.0 | 52.5 | False | None | None | False | None | False | 4935.0 | 0 | 3862019 | 147840 | None | code19.2.1 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 1663.0 | 1663.0 | 1.16 | False | None | None | False | None | False | 1929.08 | 0 | 3862020 | 147840 | None | code12.48 | Driven precast vertical M35 grade R.C.C. Piles excluding Reinforcement complete as per Drawing and & Technical SpecificationSize of pile - 300 mm x 300 mm ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | m | 3120.0 | 3120.0 | 4.8 | False | None | None | False | None | False | 14976.0 | 0 | 3862021 | 147840 | None | code1.4.1 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sidesneatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 242.0 | 242.0 | 3.68 | False | None | None | False | None | False | 890.56 | 0 | 3862022 | 147840 | None | code5.2 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 6618.0 | 6618.0 | 4.3 | False | None | None | False | None | False | 28457.4 | 0 | 3862023 | 147840 | None | code3.6 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 493.0 | 493.0 | 7.52 | False | None | None | False | None | False | 3707.36 | 0 | 3862024 | 147840 | None | code17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 1002.0 | 1002.0 | 2.51 | False | None | None | False | None | False | 2515.02 | 0 | 3862025 | 147840 | None | code2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications,M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 5338.0 | 5338.0 | 1.54 | False | None | None | False | None | False | 8220.52 | 0 | 3862026 | 147840 | None | code2.4.2 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 6789.96 | 6789.96 | 3.54 | False | None | None | False | None | False | 24036.4584 | 0 | 3862027 | 147840 | None | code2.4.2 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 6828.84 | 6828.84 | 0.7 | False | None | None | False | None | False | 4780.188 | 0 | 3862028 | 147840 | None | code2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical
specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 11271.0 | 11271.0 | 0.41 | False | None | None | False | None | False | 4621.11 | 0 | 3862029 | 147840 | None | code2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical
specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 Vol-1 ,P.No.16, I.No.2.5.1) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 10608.0 | 10608.0 | 1.58 | False | None | None | False | None | False | 16760.64 | 0 | 3862030 | 147840 | None | code2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical
specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 Vol-1 ,P.No.16, I.No.2.5.1) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 10608.0 | 10608.0 | 2.25 | False | None | None | False | None | False | 23868.0 | 0 | 3862031 | 147840 | None | code2.11d | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification,Super structure of Bridges ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | t | 86658.0 | 86658.0 | 0.72 | False | None | None | False | None | False | 62393.76 | 0 | 3862032 | 147840 | None | code6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 1310.0 | 1310.0 | 31.86 | False | None | None | False | None | False | 41736.6 | 0 | 3862033 | 147840 | None | code8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 295.0 | 295.0 | 64.12 | False | None | None | False | None | False | 18915.4 | 0 | 3862034 | 147840 | None | code9.12.2 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 1145.0 | 1145.0 | 18.25 | False | None | None | False | None | False | 20896.25 | 0 | 3862035 | 147840 | None | code8.35 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 137.0 | 137.0 | 106.12 | False | None | None | False | None | False | 14538.44 | 0 | 3862036 | 147840 | None | code11.60 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 893.0 | 893.0 | 24.03 | False | None | None | False | None | False | 21458.79 | 0 | 3862037 | 147840 | None | code11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Kg | 147.0 | 147.0 | 309.12 | False | None | None | False | None | False | 45440.64 | 0 | 3862038 | 147840 | None | code13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | l | 9.0 | 9.0 | 2000.0 | False | None | None | False | None | False | 18000.0 | 0 |
|