3863623 | 147941 | None | code01 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 7969.0 | 7969.0 | 20.966 | False | None | None | False | None | False | 167078.054 | 0 |
3863624 | 147941 | None | code02 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 1192.0 | 1192.0 | 1.89 | False | None | None | False | None | False | 2252.88 | 0 |
3863625 | 147941 | None | code03 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 10608.0 | 10608.0 | 0.546 | False | None | None | False | None | False | 5791.968 | 0 |
3863626 | 147941 | None | code04 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Kg | 86457.0 | 86457.0 | 0.0678 | False | None | None | False | None | False | 5861.7846 | 0 |
3863627 | 147941 | None | code05 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Kg | 168.0 | 168.0 | 126.0 | False | None | None | False | None | False | 21168.0 | 0 |
3863628 | 147941 | None | code06 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 1171.0 | 1171.0 | 7.2 | False | None | None | False | None | False | 8431.2 | 0 |
3863629 | 147941 | None | code07 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 99600.0 | 99600.0 | 0.059 | False | None | None | False | None | False | 5876.4 | 0 |
3863630 | 147941 | None | code08 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 5742.0 | 5742.0 | 1.89 | False | None | None | False | None | False | 10852.38 | 0 |
3863631 | 147941 | None | code09 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 295.0 | 295.0 | 117.79 | False | None | None | False | None | False | 34748.05 | 0 |
3863632 | 147941 | None | code10 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 100.0 | 100.0 | 47.0 | False | None | None | False | None | False | 4700.0 | 0 |
3863633 | 147941 | None | code11 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 89.0 | 89.0 | 117.79 | False | None | None | False | None | False | 10483.31 | 0 |
3863634 | 147941 | None | code12 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 1449.0 | 1449.0 | 70.794 | False | None | None | False | None | False | 102580.506 | 0 |
3863635 | 147941 | None | code13 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.. ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 1175.0 | 1175.0 | 80.52 | False | None | None | False | None | False | 94611.0 | 0 |
3863636 | 147941 | None | code14 | Float glass panes of nominal thickness 8 mm (weight not less than 20.00 kg/m2). ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Sqm | 628.0 | 628.0 | 7.2 | False | None | None | False | None | False | 4521.6 | 0 |
3863637 | 147941 | None | code15 | Concealed Conduit System Supplying heavy PVC condiuit pipe ……mm dia ......mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/1.2.1) 19/20mm dia
2mm thick ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 40.0 | 40.0 | 80.0 | False | None | None | False | None | False | 3200.0 | 0 |
3863638 | 147941 | None | code16 | Supplying heavy gauge PVC Conduit Pipe ….dia
…..mm thick with suitable size bends, metal junction boxes adhesive paste etx., by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.( P-2,/1.3.1) 19/20mm dia 2mm thick ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Cum | 51.0 | 51.0 | 120.0 | False | None | None | False | None | False | 6120.0 | 0 |
3863639 | 147941 | None | code17 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. (6/2.5.2) GTP of GROUP-a 1.5 sqmm ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Mtr | 20.5 | 20.5 | 50.0 | False | None | None | False | None | False | 1025.0 | 0 |
3863640 | 147941 | None | code17 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. (6/2.5.2) GTP of GROUP-a 2.5 sqmm ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Mtr | 28.0 | 28.0 | 50.0 | False | None | None | False | None | False | 1400.0 | 0 |
3863641 | 147941 | None | code18 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. (6/2.5.2) GTP of GROUP-a 2.5 sqmm ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Mtr | 41.0 | 41.0 | 50.0 | False | None | None | False | None | False | 2050.0 | 0 |
3863642 | 147941 | None | code19 | Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulatedwires, required Nos of round blocks and clamps.On wall / ceiling / Rafter / Girders ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Nos | 110.0 | 110.0 | 10.0 | False | None | None | False | None | False | 1100.0 | 0 |
3863643 | 147941 | None | code20 | Supplying capacitor type celing fan complete with down road blades shakle regulator capacities., for operation on 230 volts 50 cycles single phase AC supply confirming to ISI 374-1979 and with double ball bearing system and as per technical approved (1200 mm swing) PWD EL SR. 2022-23/Pg-43 I No.6.4.10 Rs.2949.00/Nos ---- with all lead and lifts the work shall be carried out as per the instruction of Engineer in charge of the work | Nos | 2949.0 | 2949.0 | 3.0 | False | None | None | False | None | False | 8847.0 | 0 |