createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1724648865386
version6
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee730.00
emd72500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose03-09-2024 17:00:00
tenderQueryClose03-09-2024 16:00:00
technicalBidOpen04-09-2024 17:15:00
publishedDate27-08-2024 15:54:04
publishedByPostTP_CO_HUT
publishedByUserKPE14516 - JAGANNATH
bidValidityPeriod90
noOfCalls2
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonasma begum
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8660599130
tenderSupplierListNone
tenderSchedule
createdTs1724648865389
version12
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT25450/CALL-2
titleConstruction Of Proposed 3 TPD MRF Centre Of PEB Structure Primary Shed At Hutti
descriptionConstruction Of Proposed 3 TPD MRF Centre Of PEB Structure Primary Shed At Hutti
categoryWORKS
categoryTextWorks
ecv2900000.01
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2383
locationNameDMA Town Panchayat Hutti
provisionalAmount2900000.0
groupOverheadTotal442401.44
fileNumberTP/HUTTI/MRF/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17246488650001NoneNoneOther WorksConstruction Of Proposed 3 TPD MRF Centre Of PEB Structure Primary Shed At Hutti2457598.57
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3853343147308Nonecode01KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum107.1107.129.41FalseNoneNoneFalseNoneFalse3149.8110
3853344147308Nonecode02KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5947.25947.228.97FalseNoneNoneFalseNoneFalse172290.3840
3853345147308Nonecode03KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum7322.47322.47.12FalseNoneNoneFalseNoneFalse52135.4880
3853346147308Nonecode04KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum11016.011016.01.63FalseNoneNoneFalseNoneFalse17956.080
3853347147308Nonecode05KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum7322.47322.428.62FalseNoneNoneFalseNoneFalse209567.0880
3853348147308Nonecode06KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum9820.89820.84.82FalseNoneNoneFalseNoneFalse47336.2560
3853349147308Nonecode07KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)Kg93.9393.932773.1FalseNoneNoneFalseNoneFalse260477.2830
3853350147308Nonecode08KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6708.456708.4516.67FalseNoneNoneFalseNoneFalse111829.86150
3853351147308Nonecode09KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum497.7497.7128.79FalseNoneNoneFalseNoneFalse64098.7830
3853352147308Nonecode10KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Cum1292.551292.5513.66FalseNoneNoneFalseNoneFalse17656.2330
3853353147308Nonecode11KSRB 8-8.3.1: Providing 15mm/18mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2)Sqm309.75309.75187.56FalseNoneNoneFalseNoneFalse58096.710
3853354147308Nonecode12Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kg118.65118.656130.0FalseNoneNoneFalseNoneFalse727324.50
3853355147308Nonecode13Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm596.4596.4518.21FalseNoneNoneFalseNoneFalse309060.4440
3853356147308Nonecode14KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2)Sqm105.0105.0187.56FalseNoneNoneFalseNoneFalse19693.80
3853357147308Nonecode15KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)Sqm76.6576.6591.08FalseNoneNoneFalseNoneFalse6981.2820
3853358147308Nonecode16KSRB 8-8.75.2 : Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.75.2, Page No. 53, Vol.2)Sqm76.6576.6591.08FalseNoneNoneFalseNoneFalse6981.2820
3853359147308Nonecode17KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm2764.652764.659.0FalseNoneNoneFalseNoneFalse24881.850
3853360147308Nonecode18KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)No25920.325920.31.0FalseNoneNoneFalseNoneFalse25920.30
3853361147308Nonecode19KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2)Kg474.6474.6240.0FalseNoneNoneFalseNoneFalse113904.00
3853362147308Nonecode20Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge..(Item No. 8.36.1, Page No. 47, Vol.2 PWD SR 2023-24)Sqm184.8184.8122.36FalseNoneNoneFalseNoneFalse22612.1280
3853363147308Nonecode21Aluminium Busbar/Wire Pieces. PWD ELE SR 2023-24 Page No 33 I No 69.04Kg142.8142.80.5FalseNoneNoneFalseNoneFalse71.40
3853364147308Nonecode22Supplying of Switch disconnector fuse unit (TPN)HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. PWD ELE SR 2023-24 Page No 17 I No 5.15.9Each2427.62427.611.0FalseNoneNoneFalseNoneFalse26703.60
3853365147308Nonecode23Supplying and fixing HRC fuse units base on existing switch / panel board.PWD ELE SR PAGE NO 15 I NO : 5.9.2 32A TO 63 AEach642.6642.61.0FalseNoneNoneFalseNoneFalse642.60
3853366147308Nonecode24Supplying and fixing HRC fuse link on existing switch fuse base with W loss as per IS-13703. PWD ELE SR PAGE NO 15 I NO : 5.10.1 upto 63 AEach305.55305.5511.0FalseNoneNoneFalseNoneFalse3361.050
3853367147308Nonecode25Supplying and fixing HRC fuse units base on existing switch / panel board.PWD ELE SR PAGE NO 15 I NO : 5.9.1 6A TO 16 AEach345.45345.4510.0FalseNoneNoneFalseNoneFalse3454.50
3853368147308Nonecode26SUB PANEL :Supplying&fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energy cross-3 withShort circuitbreakingcapacity of 10 Kandcomplete wiring as required confirming to IEC60898 PWD ELE SR PAGE NO 17 I NO : 5.18.9 50-63 A TPNEach3242.43242.41.0FalseNoneNoneFalseNoneFalse3242.40
3853369147308Nonecode27Supplyingof Switchdisconnector fuse unit (TPN)HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. PWD ELE SR PAGE NO 15 I NO : 5.8.1 63 AEach2427.62427.610.0FalseNoneNoneFalseNoneFalse24276.00
3853370147308Nonecode28Supplying and fixing HRC fuse units base on existing switch / panel board.PWD ELE SR PAGE NO 15 I NO : 5.9.2 32A TO 63 AEach642.6642.61.0FalseNoneNoneFalseNoneFalse642.60
3853371147308Nonecode29Supplying andfixingHRCfuselinkonexisting switchfusebasewith W loss as per IS-13703. PWD ELE SR PAGE NO 15 I NO : upto 63 AEach305.55305.5510.0FalseNoneNoneFalseNoneFalse3055.50
3853372147308Nonecode30Outgoings: 32A Industrial socket-PWD ELE SR PAGE NO 9 I NO : 3.13.2Each575.48575.482.0FalseNoneNoneFalseNoneFalse1150.960
3853373147308Nonecode31Outgoings: 16A Industrial socket-PWD ELE SR PAGE NO 9Each407.15407.152.0FalseNoneNoneFalseNoneFalse814.30
3853374147308Nonecode321.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 PWD Page No 13 I NO 32 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)m187.92187.9230.0FalseNoneNoneFalseNoneFalse5637.60
3853375147308Nonecode331.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 PWD Page No 13 I NO 3225 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm)m188.84188.8420.0FalseNoneNoneFalseNoneFalse3776.80
3853376147308Nonecode341.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 PWD Page No 13 I NO 3216 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)m148.93148.9320.0FalseNoneNoneFalseNoneFalse2978.60
3853377147308Nonecode351.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 PWD Page No 13 I NO 32 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)m123.9123.920.0FalseNoneNoneFalseNoneFalse2478.00
3853378147308Nonecode36Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 4Cx6.0 Sqmm Cu Ar cable ,3Cx6.0 Sqmm Cu Un Ar cable 3Cx 4.00 Sqmm ESCOM Page No 52 I NO 21.05m21.9321.9350.0FalseNoneNoneFalseNoneFalse1096.50
3853379147308Nonecode37Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.19/20mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-2m72.4572.4510.0FalseNoneNoneFalseNoneFalse724.50
3853380147308Nonecode38Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.25mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-2m85.0585.0510.0FalseNoneNoneFalseNoneFalse850.50
3853381147308Nonecode39Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.32mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-2m111.3111.310.0FalseNoneNoneFalseNoneFalse1113.00
3853382147308Nonecode40Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.40mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2m156.45156.4510.0FalseNoneNoneFalseNoneFalse1564.50
3853383147308Nonecode41Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.0 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-1, PAGE NO-5m19.9519.95300.0FalseNoneNoneFalseNoneFalse5985.00
3853384147308Nonecode42Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit.1.5 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-1, PAGE NO-5m27.327.3300.0FalseNoneNoneFalseNoneFalse8190.00
3853385147308Nonecode43Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit 2.5 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-1, PAGE NO-5m44.144.1300.0FalseNoneNoneFalseNoneFalse13230.00
3853386147308Nonecode44Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit 4 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-1, PAGE NO-5m52.552.550.0FalseNoneNoneFalseNoneFalse2625.00
3853387147308Nonecode45Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 1 Light point upto 3Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-1, PAGE NO-5m299.5299.51.0FalseNoneNoneFalseNoneFalse299.50
3853388147308Nonecode46Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit 1 Light point above 3M upto 6Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-1, PAGE NO-5m413.7413.71.0FalseNoneNoneFalseNoneFalse413.70
3853389147308Nonecode47Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit 1 Light point above 6M upto 10Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-1, PAGE NO-5m598.5598.51.0FalseNoneNoneFalseNoneFalse598.50
3853390147308Nonecode48Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 2 Light point above 3Mtr upto 6Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5m743.4743.41.0FalseNoneNoneFalseNoneFalse743.40
3853391147308Nonecode49Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit. 2 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2022-23, ITEM NO:2.1.4 ,CH-1, PAGE NO-5m757.05757.051.0FalseNoneNoneFalseNoneFalse757.050
3853392147308Nonecode50Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit 3 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-1, PAGE NO-5m1086.751086.753.0FalseNoneNoneFalseNoneFalse3260.250
3853393147308Nonecode51Switches & sockets outlets in Existing modular box 6A one way switch CSR Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-9No107.1107.14.0FalseNoneNoneFalseNoneFalse428.40
3853394147308Nonecode52Stepped fan regulator CSR Electrical SR-2023-24, ITEM NO:3.6.4 ,CH-3, PAGE NO-9No374.85374.852.0FalseNoneNoneFalseNoneFalse749.70
3853395147308Nonecode536/16A Universal socket CSR Electrical SR-2023-24, ITEM NO:3.6.11 ,CH-3, PAGE NO-5No247.8247.82.0FalseNoneNoneFalseNoneFalse495.60
3853396147308Nonecode54Supply of LEDStreetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising ofanti glare clear diffuserwith Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @Lumen Maintenanceof70 , maximum lightintensityshouldbebetween 60degrees to 70degrees. CCT 5500K, IP66optical andelectrical compartment &impact resistanceof complete luminaire IK08. Power Factor 0.9 withmains,SurgeProtection-Min5KValongwithOver voltage/Overload, short circuit/miss-wiring protection. Compatible for pole mounting with outer dia of 40 mm to 50mm.Universal Voltagedriver tooperatewidevoltage range from100Vto 270V 50 60Hz application. Compliance to IS 10322 IEC60598 LM79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site locationwith minimized minimal tools. LED Light fixture with .WSystem Power consumption. LED Efficiency 1301m w, nominal CRI 75. Luminaire manufacturer should have in-house facilityaccredited by NABL/CPRI any Government certified agency & Design & Development facility certified by ISO9001:2008. Housingwith supplierwordmark/name shallbe Engraved /Embossing on thediecast housing/Bodypart. Warranty of 2Years against any manufactur indefec two rkin gunder standard electrical conditionsas mentioned above should be given by LEDmanufacturer Cree Nichia Lumileds Osram make LED Source CSR Electrical SR-2023-24 ITEM NO11.8.2, PAGE NO-46 40 W LED STREETLIGHTNo4225.24225.25.0FalseNoneNoneFalseNoneFalse21126.00
3853397147308Nonecode55Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. Volume - V Water supply SR 2023-24Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
3853398147308Nonecode56PSCC Pole - 9 Mtr Long, 200 Kg WL (Dwg No. BESCOM/GM/QS&S/50 Dtd 24.11.2018) as per REC Standards VOL-6 KPTCL PG NO 3 . I no 1.06No4408.954408.955.0FalseNoneNoneFalseNoneFalse22044.750
3853399147308Nonecode57Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth VOL-6 KPTCL PG NO 44 . I no 2.02No1168.651168.655.0FalseNoneNoneFalseNoneFalse5843.250
3853400147308Nonecode58ACSR Consuctor as per IS-398 (Part-2/1996) Rabbit ACSR (6/3.35mm A1+1/3.35 mm St), Std Wt:214 Kg/KM, VOL-6 KPTCL PG NO 5 . I no 7.02m48.5548.55150.0FalseNoneNoneFalseNoneFalse7282.50
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17246488650000NoneNoneELIGIBILITYAs Per Bid DocumentNone
17246488650000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17246488650000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17246488650000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17246488650000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneSimilar Nature Of Workdone CertificatePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneQuantity Wise Workdone CertificatePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneCivil Contractor Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneLine Of Credit (Unconditioned)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneAnnual Turnover CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneCopy Of Pan CardOthersCopy Of Pan Card
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Copy Of Pan Card
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Civil Contractor CertificateTrueTechnical Bid
Line Of CreditTrueTechnical Bid
Pan And GST Registration CertificateTrueTechnical Bid
Similar Nature Of WorkdoneTrueTechnical Bid
Quantity Wise Workdone CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone