3695954 | 135908 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In All Types of Soil Depth Upto 3Mtrs | Cum | 105.06 | 105.06 | 344.568 | False | None | None | False | None | False | 36200.31408 | 0 |
3695955 | 135908 | None | code02 | Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods atevery 100 mm whevere necessary as directed, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the followingstrata.Depth exceeding 1.5 m, but not exceeding 3 m | Cum | 573.71 | 573.71 | 198.0 | False | None | None | False | None | False | 113594.58 | 0 |
3695956 | 135908 | None | code03 | Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber.
Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm
and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications
and for the following diameters and depth etc. for 1.2mm diaCirc. B M.H:Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.5M depth & SFRC cover & frame | Each | 39532.43 | 39532.43 | 15.0 | False | None | None | False | None | False | 592986.45 | 0 |
3695957 | 135908 | None | code04 | Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992, IS 4127 with latest amendments, including conveying to work site, caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying ofsewer lines etc. complete.150 mm dia. pipes | Mtr | 598.43 | 598.43 | 423.5 | False | None | None | False | None | False | 253435.105 | 0 |
3695958 | 135908 | None | code05 | Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992, IS 4127 with latest amendments, including conveying to work site, caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying ofsewer lines etc. complete.100 mm dia. pipes | Mtr | 381.1 | 381.1 | 135.0 | False | None | None | False | None | False | 51448.5 | 0 |
3695959 | 135908 | None | code06 | Constructing brick masonry chamber of internal dimension 450x300mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. | Nos | 3655.47 | 3655.47 | 30.0 | False | None | None | False | None | False | 109664.1 | 0 |
3695960 | 135908 | None | code07 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6168.67 | 6168.67 | 17.039 | False | None | None | False | None | False | 105107.96813 | 0 |
3695961 | 135908 | None | code08 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5779.33 | 5779.33 | 6.444 | False | None | None | False | None | False | 37242.00252 | 0 |
3695962 | 135908 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7375.21 | 7375.21 | 1.458 | False | None | None | False | None | False | 10753.05618 | 0 |
3695963 | 135908 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates 1) Refer Appendix-I For Formwork, Centering, Scaffolding of Isolated Footing is 8% (Pg No 115 of Common SR 2021-22) | Cum | 9219.01 | 9219.01 | 49.406 | False | None | None | False | None | False | 455474.40806 | 0 |
3695964 | 135908 | None | code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11609.13 | 11609.13 | 1.656 | False | None | None | False | None | False | 19224.71928 | 0 |
3695965 | 135908 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10926.24 | 10926.24 | 8.565 | False | None | None | False | None | False | 93583.2456 | 0 |
3695966 | 135908 | None | code13 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10243.35 | 10243.35 | 1.1398 | False | None | None | False | None | False | 11675.37033 | 0 |
3695967 | 135908 | None | code14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10243.35 | 10243.35 | 1.983 | False | None | None | False | None | False | 20312.56305 | 0 |
3695968 | 135908 | None | code15 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 164.8 | 164.8 | 504.6 | False | None | None | False | None | False | 83158.08 | 0 |
3695969 | 135908 | None | code16 | Demolishing stone rubble masonry manually/ by mechanical means
including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin-charge. | Cum | 815.76 | 815.76 | 97.6499 | False | None | None | False | None | False | 79658.882424 | 0 |
3695970 | 135908 | None | code17 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 91.67 | 91.67 | 1157.7462 | False | None | None | False | None | False | 106130.594154 | 0 |
3695971 | 135908 | None | code18 | Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure /
Superstructure complete as per Drawing and Technical Specifications. | Tonne | 92140.71 | 92140.71 | 2.47 | False | None | None | False | None | False | 227587.5537 | 0 |
3695972 | 135908 | None | code19 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8208.07 | 8208.07 | 5.518 | False | None | None | False | None | False | 45292.13026 | 0 |
3695973 | 135908 | None | code20 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6403.51 | 6403.51 | 0.945 | False | None | None | False | None | False | 6051.31695 | 0 |
3695974 | 135908 | None | code21 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Kg | 191.58 | 191.58 | 22.0 | False | None | None | False | None | False | 4214.76 | 0 |
3695975 | 135908 | None | code22 | Providing 15 mm cement plaster on rough side of single or half brick wallfinished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 359.47 | 359.47 | 52.02 | False | None | None | False | None | False | 18699.6294 | 0 |
3695976 | 135908 | None | code23 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ) | Sqm | 396.55 | 396.55 | 45.1359 | False | None | None | False | None | False | 17898.641145 | 0 |
3695977 | 135908 | None | code24 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 332.69 | 332.69 | 9.45 | False | None | None | False | None | False | 3143.9205 | 0 |
3695978 | 135908 | None | code25 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 103.0 | 103.0 | 52.02 | False | None | None | False | None | False | 5358.06 | 0 |
3695979 | 135908 | None | code26 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 141.11 | 141.11 | 52.02 | False | None | None | False | None | False | 7340.5422 | 0 |
3695980 | 135908 | None | code27 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 91.67 | 91.67 | 45.1359 | False | None | None | False | None | False | 4137.607953 | 0 |
3695981 | 135908 | None | code28 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2ncluding pointing the joints with white cement and matching pigment etc., complete. | Sqm | 1108.28 | 1108.28 | 8.16 | False | None | None | False | None | False | 9043.5648 | 0 |
3695982 | 135908 | None | code29 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint
of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 172.01 | 172.01 | 2.16 | False | None | None | False | None | False | 371.5416 | 0 |
3695983 | 135908 | None | code30 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth | Rmtr | 67.98 | 67.98 | 25.0 | False | None | None | False | None | False | 1699.5 | 0 |
3695984 | 135908 | None | code31 | Providing Raised and cut pointing: Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. | Sqm | 288.4 | 288.4 | 100.0 | False | None | None | False | None | False | 28840.0 | 0 |
3695985 | 135908 | None | code32 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1046.48 | 1046.48 | 4.0 | False | None | None | False | None | False | 4185.92 | 0 |
3695986 | 135908 | None | code33 | Providing and fixing flush door shutter made out of solid core blockboard type, well seasoned , chemicaly treated hard wood battens andinternal frame with minimum 45 mm wide wooden frame alrounddoor shutters covered with cross bonded wooden sheets (core veneer)hot pressed and fastened on both sides of the door useing liquidphenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification.do- 35 mm thick one side teak and one side commercial | Sqm | 4013.91 | 4013.91 | 10.08 | False | None | None | False | None | False | 40460.2128 | 0 |
3695987 | 135908 | None | code34 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1433.76 | 1433.76 | 17.28 | False | None | None | False | None | False | 24775.3728 | 0 |
3695988 | 135908 | None | code35 | Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification) | Sqm | 1195.83 | 1195.83 | 124.15 | False | None | None | False | None | False | 148462.2945 | 0 |
3695989 | 135908 | None | code36 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 76.437 | False | None | None | False | None | False | 20942.20926 | 0 |
3695990 | 135908 | None | code37 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 5.0 | False | None | None | False | None | False | 610.0 | 0 |
3695991 | 135908 | None | code38 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burninghours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V@ 50/60Hz & Power factor 0.9 along with CEapproved. 2 years Warranty against any manufacturing defectworking under standard electrical condition.LED light fitting 1 x 4' - 20/22 W | Each | 690.0 | 690.0 | 5.0 | False | None | None | False | None | False | 3450.0 | 0 |
3695992 | 135908 | None | code39 | Fixing of ..... Amps TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labeling 15A to 63A TPST (PWD Electrical SR 2022-23 P no 46 I no 13.18.1) | Mtr | 278.0 | 278.0 | 5.0 | False | None | None | False | None | False | 1390.0 | 0 |
3695993 | 135908 | None | code40 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. (PWD Electrical SR 2022-23 P no. 10 I no 5.5.2) 63Amps | Nos | 4193.0 | 4193.0 | 5.0 | False | None | None | False | None | False | 20965.0 | 0 |
3695994 | 135908 | None | code41 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box,elbows, screws at an interval of 300 mm .... etc. as required.25mm | Each | 35.0 | 35.0 | 50.0 | False | None | None | False | None | False | 1750.0 | 0 |
3695995 | 135908 | None | code42 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. (PWD Electrical SR 2022-23 P No 5 I no 3.3.6) 16-18 Way | Mtr | 261.0 | 261.0 | 5.0 | False | None | None | False | None | False | 1305.0 | 0 |
3695996 | 135908 | None | code43 | Supplying & fixing modular swich/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate (6Amps one way) | Mtr | 162.0 | 162.0 | 5.0 | False | None | None | False | None | False | 810.0 | 0 |
3695997 | 135908 | None | code44 | Supplying and fixing superior quality modular switch mountingpolycarbonate plate with necessary supporting back plate withrequired nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.16-18 Module | Each | 339.0 | 339.0 | 2.0 | False | None | None | False | None | False | 678.0 | 0 |
3695998 | 135908 | None | code45 | Wiring for lighting/power circuit using one of FRLS PVCnsulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5Sqmm | Mtr | 26.0 | 26.0 | 25.0 | False | None | None | False | None | False | 650.0 | 0 |
3695999 | 135908 | None | code46 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. | Each | 63.0 | 63.0 | 25.0 | False | None | None | False | None | False | 1575.0 | 0 |
3696000 | 135908 | None | code47 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS1293 and IS 3654 6A 2 Way | Each | 128.0 | 128.0 | 5.0 | False | None | None | False | None | False | 640.0 | 0 |
3696001 | 135908 | None | code48 | Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket | Each | 171.0 | 171.0 | 5.0 | False | None | None | False | None | False | 855.0 | 0 |
3696002 | 135908 | None | code49 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.600w dimmer | Each | 329.0 | 329.0 | 5.0 | False | None | None | False | None | False | 1645.0 | 0 |
3696003 | 135908 | None | code50 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16A Universal Socket | Each | 156.0 | 156.0 | 3.0 | False | None | None | False | None | False | 468.0 | 0 |
3696004 | 135908 | None | code51 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16A One Way Switch | Each | 177.0 | 177.0 | 3.0 | False | None | None | False | None | False | 531.0 | 0 |
3696005 | 135908 | None | code52 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing material sand 'C'Type curve,indicator ON/OFF,energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. 50-63 A TPN | Each | 3088.0 | 3088.0 | 2.0 | False | None | None | False | None | False | 6176.0 | 0 |
3696006 | 135908 | None | code53 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.6 Way SP & N | Mtr | 1186.0 | 1186.0 | 1.0 | False | None | None | False | None | False | 1186.0 | 0 |
3696007 | 135908 | None | code54 | Supplying and fixing Wiring Earth Electrode For grounding conduits ic cutouts on the meter board using 40mm dia 2.90mm thick GI Pipe 2.50mtr long burried in a pit the pit should be filled up with equal propotion of salt & charcoal 150mm alll around the pipe to complete depth pwd ele SR 2019-20 P.No 40 I.No 6.1 | Mtr | 3510.0 | 3510.0 | 1.0 | False | None | None | False | None | False | 3510.0 | 0 |
3696008 | 135908 | None | code55 | For Electrical & Hescom Charges | Each | 10000.0 | 10000.0 | 1.0 | False | None | None | False | None | False | 10000.0 | 0 |
3696009 | 135908 | None | code56 | Providing & Fixing CPVC Pipes having thermal steability of hot & cold water supply including fixing the pipe clamp @ 1mtr spacing this includes jointing of pipes etc with CPVC Salvent 20mm nominal od pipe pwd sr 2021-22 1st addendum Vol2 sl no 09 ino 13.31.2 | Each | 242.0 | 242.0 | 20.0 | False | None | None | False | None | False | 4840.0 | 0 |
3696010 | 135908 | None | code57 | Providing & Fixing CPVC Pipes having thermal steability of hot & cold water supply including fixing the pipe clamp @ 1mtr spacing this includes jointing of pipes etc with CPVC Salvent 25mm nominal od pipe pwd sr 2021-22 1st addendum Vol2 sl no 09 ino 13.31.2 | Mtr | 318.0 | 318.0 | 20.0 | False | None | None | False | None | False | 6360.0 | 0 |
3696011 | 135908 | None | code58 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 | Nos | 635.0 | 635.0 | 4.0 | False | None | None | False | None | False | 2540.0 | 0 |
3696012 | 135908 | None | code59 | Providing and fixing unplasticised PVC connection pipe with brass unions :45 cm length 20 mm nominal bore (PWD SR 2021-22 Vol:2 P.NO.116 I.No:13.8.2.2) | Nos | 110.0 | 110.0 | 4.0 | False | None | None | False | None | False | 440.0 | 0 |
3696013 | 135908 | None | code60 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : (PWD SR 2021-22 Vol:2 P.NO. 123 I.No:14.2.1) | Each | 4838.0 | 4838.0 | 4.0 | False | None | None | False | None | False | 19352.0 | 0 |
3696014 | 135908 | None | code61 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. PWD SR 2021-22 vol-5 Page no-187 I.No-10 | Each | 4236.0 | 4236.0 | 4.0 | False | None | None | False | None | False | 16944.0 | 0 |
3696015 | 135908 | None | code62 | Supplying lowering laying, jointing, testing and commissioning of following5 diameters glazed stone ware pipes, conforming to IS 651:1992, (with 5th revision) in all respects jointing with EPDM rubber rings (seals according to EN 681 & ASPM 425) The rubber seals joints pipe will have groves in interior of socket and exterior of the spigot. The rubber gasket shall be prefixed at the factory by the manufacturer rigidly with approved glue to have leak proof joint including conveying of pipe to work site and rolling and lowering into trenches, laying true to line, level and perfect linking at joints testing and commissoning including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of GSW pipes and specials, with rubber gaskets conforming to EN 681 and ASTM C-425 including cleaning the socket and spigot with soap solution and applying talcum powder for detecting crack, then applying glue and before inserting of rubber gaskets, jacking and fixing in perfect condition including the cost of soap solution, talcum powder and glue etc. and giving necessary hydraulic test to the required pressure of water head with all lead and lifts including costing of jointing materials and all necessary surve works for laying of sewers etc., and disposal of debris as directed etc., complete. (Contractor will make his own arrangements for procuring water for testing) with Rubber ring gasket joints 100 mm dia. pipes (This is for house service connection only) PWD SR 2021-22 vol-5 Page no-184 I.no-2.1 | Mtr | 370.0 | 370.0 | 50.0 | False | None | None | False | None | False | 18500.0 | 0 |
3696016 | 135908 | None | code63 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latestamendments and conveying to worksite, rolling and lowering intotrenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 75mm dia., 6 kg/sqcm & class 3 PWD SR 2021-22 Page no-134 I.NO-1.5 | Mtr | 220.0 | 220.0 | 6.0 | False | None | None | False | None | False | 1320.0 | 0 |
3696017 | 135908 | None | code64 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.PWD SR 2021-22 Vol-2 page no 127 I.No-14.22A | Each | 810.0 | 810.0 | 2.0 | False | None | None | False | None | False | 1620.0 | 0 |
3696018 | 135908 | None | code65 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.PWD SR 2021-22 Vol-2 page no 127 I.No- 14.28.2 Flexible pipe | Each | 92.0 | 92.0 | 2.0 | False | None | None | False | None | False | 184.0 | 0 |
3696019 | 135908 | None | code66 | Providing & Fixing on terrace on polythene water storage tank marked with cover & suitable locking arrangements (pwd sr 2021-22 1st addedam vol 2 sl/no 12.1 i.no 13.34 | Ltr | 9.0 | 9.0 | 2000.0 | False | None | None | False | None | False | 18000.0 | 0 |
3696020 | 135908 | None | code67 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:15 mm nominal bore (PWD SR 2021-22 Vol:2 P.NO.115 I.No:13.5.1) | Nos | 296.0 | 296.0 | 2.0 | False | None | None | False | None | False | 592.0 | 0 |
3696021 | 135908 | None | code68 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. (PWD SR 2021-22 Vol:2 P.NO.130 I.No:14.40.1)) | Each | 478.0 | 478.0 | 4.0 | False | None | None | False | None | False | 1912.0 | 0 |
3696022 | 135908 | None | code69 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.4 Kg/m2: 63mm(weight of pipe -0.465 kg) 90mm(weight of pipe -0.917 kg) (WS & UGD Common SR 2021-22 Vol:5 P.NO.120.No: 10.14.3 SOR Code : M150C) | Mtr | 210.0 | 210.0 | 50.0 | False | None | None | False | None | False | 10500.0 | 0 |
3696023 | 135908 | None | code70 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 581.95 | 581.95 | 321.3 | False | None | None | False | None | False | 186980.535 | 0 |