tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1724842011000 | 0 | None | None | Buildings | Construction of First Floor | 1945506.72 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3873437 | 148499 | None | MAH01 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer in-charge.In cement mortar | Cum | 1785.88 | 1785.88 | 10.215 | False | None | None | False | None | False | 18242.7642 | 0 | 3873438 | 148499 | None | MAH02 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11904.17 | 11904.17 | 0.4761 | False | None | None | False | None | False | 5667.575337 | 0 | 3873439 | 148499 | None | MAH03 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8451.12 | 8451.12 | 43.4741 | False | None | None | False | None | False | 367404.835992 | 0 | 3873440 | 148499 | None | MAH04 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement Paid Separately & formwork included to Finish Rate with All lead and lift) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11208.02 | 11208.02 | 8.4481 | False | None | None | False | None | False | 94686.473762 | 0 | 3873441 | 148499 | None | MAH05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement Paid Separately & formwork included to Finish Rate with All lead and lift) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10163.79 | 10163.79 | 1.4805 | False | None | None | False | None | False | 15047.491095 | 0 | 3873442 | 148499 | None | MAH06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement Paid Separately & formwork included to Finish Rate with All lead and lift) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10511.87 | 10511.87 | 19.935 | False | None | None | False | None | False | 209554.12845 | 0 | 3873443 | 148499 | None | MAH07 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 255.58 | 255.58 | 197.64 | False | None | None | False | None | False | 50512.8312 | 0 | 3873444 | 148499 | None | MAH08 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 393.45 | 393.45 | 152.9325 | False | None | None | False | None | False | 60171.292125 | 0 | 3873445 | 148499 | None | MAH09 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification.Buildings | Tonne | 94.87 | 94.87 | 3089.504 | False | None | None | False | None | False | 293101.24448 | 0 | 3873446 | 148499 | None | MAH10 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm | Sqm | 1214.27 | 1214.27 | 178.577 | False | None | None | False | None | False | 216840.69379 | 0 | 3873447 | 148499 | None | MAH11 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 131716.22 | 131716.22 | 0.774 | False | None | None | False | None | False | 101948.35428 | 0 | 3873448 | 148499 | None | MAH12 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 6089.39 | 6089.39 | 6.1425 | False | None | None | False | None | False | 37404.078075 | 0 | 3873449 | 148499 | None | MAH13 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 178.16 | 178.16 | 243.0 | False | None | None | False | None | False | 43292.88 | 0 | 3873450 | 148499 | None | MAH14 | Providing and fixing in position fully glazed shutters for ventilators side hung or central pivoted with Mathi/Nandi wood stiles and rails of 30mm thick 50mm wide and central divider of 30mm. wide, 3mm thick reeded glass fixed with wooden beading of size 10mm wide flushed to the thickness of the frame including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 6505.11 | 6505.11 | 14.175 | False | None | None | False | None | False | 92209.93425 | 0 | 3873451 | 148499 | None | MAH15 | Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ m2 (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. | Sqm | 1283.21 | 1283.21 | 69.68 | False | None | None | False | None | False | 89414.0728 | 0 | 3873452 | 148499 | None | MAH16 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 106.05 | 106.05 | 333.271 | False | None | None | False | None | False | 35343.38955 | 0 | 3873453 | 148499 | None | MAH17 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 121.96 | 121.96 | 50.76 | False | None | None | False | None | False | 6190.6896 | 0 | 3873454 | 148499 | None | MAH18 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.29 | 145.29 | 333.271 | False | None | None | False | None | False | 48420.94359 | 0 | 3873455 | 148499 | None | MAH19 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two coats on new work to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 84.84 | 84.84 | 152.9325 | False | None | None | False | None | False | 12974.7933 | 0 | 3873456 | 148499 | None | MAH20 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-Charge. | Kg | 146.35 | 146.35 | 193.32 | False | None | None | False | None | False | 28292.382 | 0 | 3873457 | 148499 | None | MAH21 | Providing and fixing 12 m thick flat pressed 3 layer medium density particle board or graded particle board (Grade I) IS: 3087 marked, in ceiling with necessary nails etc. complete. | Sqm | 785.4 | 785.4 | 13.5 | False | None | None | False | None | False | 10602.9 | 0 | 3873458 | 148499 | None | MAH22 | Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 781.59 | 781.59 | 138.414 | False | None | None | False | None | False | 108182.99826 | 0 |
| 1724842011000 | 0 | None | None | Buildings | Electrification work Internal and External | 103243.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3873459 | 148500 | None | MAH23 | Supplying heavy gauge PVC conduit pipe .mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick
| m | 70.0 | 70.0 | 90.0 | False | None | None | False | None | False | 6300.0 | 0 | 3873460 | 148500 | None | MAH24 | Supplying heavy gauge PVC Conduit Pipe dia.mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick
| m | 80.0 | 80.0 | 50.0 | False | None | None | False | None | False | 4000.0 | 0 | 3873461 | 148500 | None | MAH25 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box
| Each | 51.0 | 51.0 | 16.0 | False | None | None | False | None | False | 816.0 | 0 | 3873462 | 148500 | None | MAH26 | Supplying And Fixing Metal Fan Box with Round Hook.
| No | 163.0 | 163.0 | 6.0 | False | None | None | False | None | False | 978.0 | 0 | 3873463 | 148500 | None | MAH27 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3m from tapping point to out let via switch
| Point | 276.0 | 276.0 | 12.0 | False | None | None | False | None | False | 3312.0 | 0 | 3873464 | 148500 | None | MAH28 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outletMedium point above 3m upto 6m from tapping point to out let via switch
| Point | 386.0 | 386.0 | 6.0 | False | None | None | False | None | False | 2316.0 | 0 | 3873465 | 148500 | None | MAH29 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Long point above 6m upto 10m from tapping point to out let via switch
| Point | 567.0 | 567.0 | 3.0 | False | None | None | False | None | False | 1701.0 | 0 | 3873466 | 148500 | None | MAH30 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2
| m | 26.0 | 26.0 | 180.0 | False | None | None | False | None | False | 4680.0 | 0 | 3873467 | 148500 | None | MAH31 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments2.5 mm2
| m | 40.0 | 40.0 | 220.0 | False | None | None | False | None | False | 8800.0 | 0 | 3873468 | 148500 | None | MAH32 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 4 mm2
| m | 59.0 | 59.0 | 120.0 | False | None | None | False | None | False | 7080.0 | 0 | 3873469 | 148500 | None | MAH33 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 6 mm2
| m | 87.0 | 87.0 | 30.0 | False | None | None | False | None | False | 2610.0 | 0 | 3873470 | 148500 | None | MAH34 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 3/5 Way
| Each | 143.0 | 143.0 | 15.0 | False | None | None | False | None | False | 2145.0 | 0 | 3873471 | 148500 | None | MAH35 | Supplying and mounting 2 Nos. of 2Way 6 A flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden
box and wiring as per IS 1293"
| Each | 162.0 | 162.0 | 3.0 | False | None | None | False | None | False | 486.0 | 0 | 3873472 | 148500 | None | MAH36 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1-3 Way
| Each | 91.0 | 91.0 | 2.0 | False | None | None | False | None | False | 182.0 | 0 | 3873473 | 148500 | None | MAH37 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 4-5 Way
| Each | 122.0 | 122.0 | 1.0 | False | None | None | False | None | False | 122.0 | 0 | 3873474 | 148500 | None | MAH38 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 8 Way
| Each | 195.0 | 195.0 | 3.0 | False | None | None | False | None | False | 585.0 | 0 | 3873475 | 148500 | None | MAH39 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 10-12 Way
| Each | 277.0 | 277.0 | 3.0 | False | None | None | False | None | False | 831.0 | 0 | 3873476 | 148500 | None | MAH40 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module
| Each | 152.0 | 152.0 | 2.0 | False | None | None | False | None | False | 304.0 | 0 | 3873477 | 148500 | None | MAH41 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 4 Module
| Each | 175.0 | 175.0 | 1.0 | False | None | None | False | None | False | 175.0 | 0 | 3873478 | 148500 | None | MAH42 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 8 Module
| Each | 302.0 | 302.0 | 3.0 | False | None | None | False | None | False | 906.0 | 0 | 3873479 | 148500 | None | MAH43 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 10-12 Module
| Each | 363.0 | 363.0 | 3.0 | False | None | None | False | None | False | 1089.0 | 0 | 3873480 | 148500 | None | MAH44 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module
| Each | 313.0 | 313.0 | 6.0 | False | None | None | False | None | False | 1878.0 | 0 | 3873481 | 148500 | None | MAH45 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32A DP Switch
| Each | 375.0 | 375.0 | 2.0 | False | None | None | False | None | False | 750.0 | 0 | 3873482 | 148500 | None | MAH46 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16A Universal Socket
| Each | 249.0 | 249.0 | 5.0 | False | None | None | False | None | False | 1245.0 | 0 | 3873483 | 148500 | None | MAH47 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 TV/Telephone Socket
| Each | 147.0 | 147.0 | 3.0 | False | None | None | False | None | False | 441.0 | 0 | 3873484 | 148500 | None | MAH48 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 RJ45/I.O Outlet Cat-6
| Each | 211.0 | 211.0 | 1.0 | False | None | None | False | None | False | 211.0 | 0 | 3873485 | 148500 | None | MAH49 | Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply completely wired on existing box.
| Each | 747.0 | 747.0 | 1.0 | False | None | None | False | None | False | 747.0 | 0 | 3873486 | 148500 | None | MAH50 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws.
| Sqm | 0.29 | 0.29 | 2000.0 | False | None | None | False | None | False | 580.0 | 0 | 3873487 | 148500 | None | MAH51 | Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size . mm conduit using necessary machine screws. 80 mm
| No | 10.0 | 10.0 | 16.0 | False | None | None | False | None | False | 160.0 | 0 | 3873488 | 148500 | None | MAH52 | Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size . mm conduit using necessary machine screws 110 mm
| No | 12.0 | 12.0 | 12.0 | False | None | None | False | None | False | 144.0 | 0 | 3873489 | 148500 | None | MAH53 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.6A Bakelite Ceiling Rose
| No | 63.0 | 63.0 | 12.0 | False | None | None | False | None | False | 756.0 | 0 | 3873490 | 148500 | None | MAH54 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Lamp Holder
| No | 63.0 | 63.0 | 8.0 | False | None | None | False | None | False | 504.0 | 0 | 3873491 | 148500 | None | MAH55 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16A SP Switch
| No | 106.0 | 106.0 | 6.0 | False | None | None | False | None | False | 636.0 | 0 | 3873492 | 148500 | None | MAH56 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 32A Bakelite DP
| No | 200.0 | 200.0 | 4.0 | False | None | None | False | None | False | 800.0 | 0 | 3873493 | 148500 | None | MAH57 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board16/6A combined plug and socket with control switch
| No | 281.0 | 281.0 | 4.0 | False | None | None | False | None | False | 1124.0 | 0 | 3873494 | 148500 | None | MAH58 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP
| Each | 523.0 | 523.0 | 2.0 | False | None | None | False | None | False | 1046.0 | 0 | 3873495 | 148500 | None | MAH59 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP
| Each | 1103.0 | 1103.0 | 1.0 | False | None | None | False | None | False | 1103.0 | 0 | 3873496 | 148500 | None | MAH60 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.6 Way SP & N
| Each | 1552.0 | 1552.0 | 1.0 | False | None | None | False | None | False | 1552.0 | 0 | 3873497 | 148500 | None | MAH61 | Supplying, fixing and wiring Earth Leakage Miniature Circuit
Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board.32-40 A 4 pole"
| Each | 2826.0 | 2826.0 | 1.0 | False | None | None | False | None | False | 2826.0 | 0 | 3873498 | 148500 | None | MAH62 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model
| Each | 2085.0 | 2085.0 | 6.0 | False | None | None | False | None | False | 12510.0 | 0 | 3873499 | 148500 | None | MAH63 | Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply.400 mm Sweep
| Each | 2838.0 | 2838.0 | 2.0 | False | None | None | False | None | False | 5676.0 | 0 | 3873500 | 148500 | None | MAH64 | Supplying and drawing UTP-CAT 6E LAN cable.
| m | 34.0 | 34.0 | 12.0 | False | None | None | False | None | False | 408.0 | 0 | 3873501 | 148500 | None | MAH65 | Supplying and fixing retrofit type PL LED lamp w LED linear source with CCT 6500 degree K CR 70 efficacy 80 Lumen per W life 25000 burning hours and compliance to IS 10322 IEC 60598 LM 79 and LM 80 The LED are driven by HF electronic driver integrated in the system with PF 0.95 power loss should 5 of lamp wage short circuit and open circuit THD less than 20 life as per LM 79 the operating input voltage should be between 130 to 275 V Tested by NABL CPRI accredited laboratory with 2 Years Warranty against any | Each | 613.0 | 613.0 | 4.0 | False | None | None | False | None | False | 2452.0 | 0 | 3873502 | 148500 | None | MAH66 | Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with life of 25000 burning hours abd 70 Lumen maintenance with CRI 80 power input 220 240 V at 50 60 Hz and power factor 0.9 along with CE approved 2 Years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 x4 20 22W | Each | 740.0 | 740.0 | 18.0 | False | None | None | False | None | False | 13320.0 | 0 | 3873503 | 148500 | None | MAH67 | SSupplying of recess mounting non integrated type LED down light W luminaire comprising of pressure decast extruded aluminium housing with spring loaded false ceiling CIA LED of power COB with CCT 6500 degree K CRI 70 efficacy 100 lumen per W 120 degree beam spread life 25000 burning hours and compliance o IS10322 IEC 60598 LM 79 and LM 80 The lamp compartment is enclosed with antiglare opal diffuser which enhances the lighting level LED are driven by HF electronic driver integrated in a separte control gear assembly with PF 0.95 power loss should 5 of lamp wage short circuit and open circuit protection to be integrated in the circuit THD less than 20 life as per LM 79 the operating input voltage should be between 130 to 275 V BIS approved and tested by NABL CPRI accredited laboratory with 2 Years warranty against any manufacturing defect working under | Each | 1478.0 | 1478.0 | 2.0 | False | None | None | False | None | False | 2956.0 | 0 |
| 1724842011000 | 0 | None | None | Buildings | Toilet | 300095.66 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3873504 | 148501 | None | MAH68 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 14.8275 | False | None | None | False | None | False | 1588.02525 | 0 | 3873505 | 148501 | None | MAH69 | Providing and laying in position Cement Concrete for levelling course forall works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality,labour,Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 1.2135 | False | None | None | False | None | False | 7216.9272 | 0 | 3873506 | 148501 | None | MAH70 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8631.0 | 8631.0 | 2.0016 | False | None | None | False | None | False | 17275.8096 | 0 | 3873507 | 148501 | None | MAH71 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 339.15 | 339.15 | 9.8256 | False | None | None | False | None | False | 3332.35224 | 0 | 3873508 | 148501 | None | MAH72 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately and Form work icluded to finished rate with all lead and lifts) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9958.73 | 9958.73 | 0.3 | False | None | None | False | None | False | 2987.619 | 0 | 3873509 | 148501 | None | MAH73 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 11.19 | False | None | None | False | None | False | 65926.4445 | 0 | 3873510 | 148501 | None | MAH74 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately and Form work icluded to finished rate with all lead and lifts) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10622.64 | 10622.64 | 0.6126 | False | None | None | False | None | False | 6507.429264 | 0 | 3873511 | 148501 | None | MAH75 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 5.6871 | False | None | None | False | None | False | 47586.524895 | 0 | 3873512 | 148501 | None | MAH76 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately and Form work icluded to finished rate with all lead and lifts) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11138.4 | 11138.4 | 1.0301 | False | None | None | False | None | False | 11473.66584 | 0 | 3873513 | 148501 | None | MAH77 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately and Form work icluded to finished rate with all lead and lifts) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 1.0886 | False | None | None | False | None | False | 11367.43335 | 0 | 3873514 | 148501 | None | MAH78 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification.Buildings | Tonne | 93.93 | 93.93 | 302.5396 | False | None | None | False | None | False | 28417.544628 | 0 | 3873515 | 148501 | None | MAH79 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 404.25 | 404.25 | 70.29 | False | None | None | False | None | False | 28414.7325 | 0 | 3873516 | 148501 | None | MAH80 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 933.45 | 933.45 | 2.82 | False | None | None | False | None | False | 2632.329 | 0 | 3873517 | 148501 | None | MAH81 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1161.3 | 1161.3 | 13.0125 | False | None | None | False | None | False | 15111.41625 | 0 | 3873518 | 148501 | None | MAH82 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 5128.2 | 5128.2 | 1.0 | False | None | None | False | None | False | 5128.2 | 0 | 3873519 | 148501 | None | MAH83 | 2.5 cms thick Tandur blue slabs | Sqm | 283.5 | 283.5 | 2.7 | False | None | None | False | None | False | 765.45 | 0 | 3873520 | 148501 | None | MAH84 | Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). - 10cms x 7.5cms | Each | 262.5 | 262.5 | 4.0 | False | None | None | False | None | False | 1050.0 | 0 | 3873521 | 148501 | None | MAH85 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Mtr | 413.7 | 413.7 | 3.0 | False | None | None | False | None | False | 1241.1 | 0 | 3873522 | 148501 | None | MAH86 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 75mm dia., 6 kg/sqcm & class 3 | Mtr | 220.5 | 220.5 | 5.0 | False | None | None | False | None | False | 1102.5 | 0 | 3873523 | 148501 | None | MAH87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes & fittings with one step CPVC Solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge External work 25mm nominal dia pipes | Mtr | 313.95 | 313.95 | 8.0 | False | None | None | False | None | False | 2511.6 | 0 | 3873524 | 148501 | None | MAH88 | Providing and placing on terrace (at all floor levels) polythelene water storage tank IS:12701 marked with cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 8.4 | 8.4 | 750.0 | False | None | None | False | None | False | 6300.0 | 0 | 3873525 | 148501 | None | MAH89 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two coats on new work to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 84.0 | 84.0 | 70.29 | False | None | None | False | None | False | 5904.36 | 0 | 3873526 | 148501 | None | MAH90 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Sqm | 333.9 | 333.9 | 1.575 | False | None | None | False | None | False | 525.8925 | 0 | 3873527 | 148501 | None | MAH91 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. do- with both side prelam | Sqm | 2484.3 | 2484.3 | 1.575 | False | None | None | False | None | False | 3912.7725 | 0 | 3873528 | 148501 | None | MAH92 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 8689.8 | 8689.8 | 1.89 | False | None | None | False | None | False | 16423.722 | 0 | 3873529 | 148501 | None | MAH93 | Providing assembling and supplying vision glass panels IGUS comprising of hermetically sealed 6 12 6 mm insulated glass doubled glazed vision panel units of size and shape as required and specified comprising of an outer heat strenghtened float glass 6 mm thick of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade an inner heat strenghned clear float glass 6mm thick spacer tube 12mm wide dessicants including primary seal and secondary seal (structural silicone sealant ) etc all complete for the requied performances as per the architectural drawings as per the approved shop drawings as specified and as directed by the engineer in charge the IGUS shall be assembled in the factory worshop of the glass processor (payment for fixing of IGU panels in the curtain glazing is included in cost of item No 18.2) for payment only the actual area of glass on face of the glass panels (excluding the areas of the grooves and wether silicone seal ant) provided and fixed in position shall be measured in colored tinted float glass 6 mm thcik substrate with reflective soft coating on face 2 +12mm airgap 6mm heat strengthened clear glass of approved make having properties as visible light transmittance (VLT) of 25 to 35 Light reflection internal 10 to 15 light reflection external 10 to 20 shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W m2 degree K etc The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement | Sqm | 3195.15 | 3195.15 | 1.6875 | False | None | None | False | None | False | 5391.815625 | 0 |
|
|
---|