createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1724249463129
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd11642.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose06-09-2024 17:30:00
tenderQueryClose01-09-2024 17:30:00
technicalBidOpen10-09-2024 11:00:00
publishedDate28-08-2024 18:20:44
publishedByPostDMA_EE1_CC_BLR
publishedByUserKPE16049 - T A MANJUNATHA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonManjunath T A
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9742138927
tenderSupplierListNone
tenderSchedule
createdTs1724249463178
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/WS/WORK_INDENT20346
titleProviding ugd pipe and construction of MH chambers in venkataramanagar link road from Dadapheer home to Khajapeer home in ward 9 ballari city
descriptionProviding ugd pipe and construction of MH chambers in venkataramanagar link road from Dadapheer home to Khajapeer home in ward 9 ballari city.
categoryWORKS
categoryTextWorks
ecv465537.32
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location2154
locationNameDMA City Corporation Ballari
provisionalAmount465660.0
groupOverheadTotal71014.17
fileNumberCCB/ENG/UGD/GG/02/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17242494630000NoneNoneWater supply/sewage linesProviding ugd pipe and construction of MH chambers in venkataramanagar link road from Dadapheer home to Khajapeer home in ward 9 ballari city394523.15
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3831633146030Nonecode01Dismantling of cement concrete pavement by mechanical means using pneumatic tools breaking to pieces not exceeding point zero two m3 in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable materials separately. Vol 3 SR 202324, P.no. 12, I.No. 2.19.Cum591.15591.157.5FalseNoneNoneFalseNoneFalse4433.6250
3831634146030Nonecode02Earth work in surface excavation by mechanical means for lowering and leveling the ground without blasting for all works other than foundation in Ordinary Soft rock and depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenances required to complete the work .CMSR 23 24,VOL 1,P.NO 8, i NO 1.13Cum380.1380.1167.22FalseNoneNoneFalseNoneFalse63560.3220
3831635146030Nonecode03Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for:CMSR 23-24 VOL-5 P.N0.113,I.NO.10.2.10Rmtr731.85731.85150.0FalseNoneNoneFalseNoneFalse109777.50
3831636146030Nonecode04Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1 4 plaster with bricks of approved quality and CM plaster 1 3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 124 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592 Part 1 1988 and IS 12592 Part-II 1991 with latest amendments in CC 1 2 4, Providing and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. With Table Moulded Bricks and Medium Duty cover and frame.For 1.5m dia 16.42.1 Constructing Table Moulded Bricks Machinehole 1.5 m internal dia. , 1.0 M depth & Medium duty SFRC cover & frame CMSR 23 24 I.NO 16.42.1,16.42.2 P.NO202 for 1 mtr depthEach25566.4525566.452.0FalseNoneNoneFalseNoneFalse51132.90
3831637146030Nonecode05Providing and constructing of Machinehole chambers conical in shape at top with CC 1 3 6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1 4 plaster with bricks of approved quality and CM plaster 1 3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1 2 4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592 Part I 1988 and IS 12592 Part II 1991 with latest amendments in CC 1 2 4, Providing and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing, barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. With Table Moulded Bricks and Medium Duty cover and frame.For 1.2m dia. VOL 5 SR 2023 24, P.no 201, I.No.16.40.1, 16.40.2 1. I.No.40.1 T510A Constructing Table Moulded Bricks Machinehole 1.2 m internal dia. 1.2 M depth and Medium duty SFRC cover and frameEach30208.7130208.712.0FalseNoneNoneFalseNoneFalse60417.420
3831638146030Nonecode06Providing and constructing of Machinehole chambers conical in shape at top with CC 1 3 6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1 4 plaster with bricks of approved quality and CM plaster 1 3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1 2 4 with graded metal of 20 mm and down size including Providing and fixing SFRC Machinehole frame and cover confoming to IS 12592 Part I 1988 and IS 12592 Part II 1991 with latest amendments in CC 1 2 4, Providing and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing, barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. With Table Moulded Bricks and Medium Duty cover and frame.For 1.2m dia. VOL 5 SR 2023 24, P.no 201, I.No.16.40.1, 16.40.2 1. I.No.40.1 T510A Constructing Table Moulded Bricks Machinehole 1.2 m internal dia. 1.3M depth and Medium duty SFRC cover and frameEach32529.8432529.842.0FalseNoneNoneFalseNoneFalse65059.680
3831639146030Nonecode07Refilling available earth around trenches pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications CMSR 23 24,VOL 1,P.NO 7,I.NO 1.10Cum168.0168.0167.22FalseNoneNoneFalseNoneFalse28092.960
3831640146030Nonecode08Providing PVC ringtite pipes conforming to IS 4985 2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc. complete For CMSR 2324,P.NO 113,I.NO 10.1.1, 10.1.7 25 mmdia pvc 6kg sqcmRmtr50.450.425.0FalseNoneNoneFalseNoneFalse1260.00
3831641146030Nonecode09Providing PVC ringtite pipes conforming to IS 4985 2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc. complete For CMSR 2324,P.NO 113,I.NO 10.1.1, 10.1.7 110 mmdia pvc 6kg sqcmRmtr431.55431.5525.0FalseNoneNoneFalseNoneFalse10788.750
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17242494640000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17242494640000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17242494640000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17242494640000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17242494640000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNonekpwd registration certificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneBanker DetailsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNonenot applicableOthersnot applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- not applicable
NoneNoneNoneNonenot applicableOthersnot applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- not applicable
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone