1724833388000 | 0 | None | None | Buildings | Construction of Panchakarma theatre at Kushalanagara Govt Ayurvedic hospital | 2499632.77 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3872479 | 148441 | None | code01 | Making the opening in brick masonry for door/window/clerestory window including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge.with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 1171.52 | 1171.52 | 1.34 | False | None | None | False | None | False | 1569.8368 | 0 | 3872480 | 148441 | None | code02 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 1152.48 | 1152.48 | 1.58 | False | None | None | False | None | False | 1820.9184 | 0 | 3872481 | 148441 | None | code03 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 1862.56 | 1862.56 | 1.69 | False | None | None | False | None | False | 3147.7264 | 0 | 3872482 | 148441 | None | code04 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 271.04 | 271.04 | 24.84 | False | None | None | False | None | False | 6732.6336 | 0 | 3872483 | 148441 | None | code05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical sp ecifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 6343.68 | 6343.68 | 4.32 | False | None | None | False | None | False | 27404.6976 | 0 | 3872484 | 148441 | None | code06 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 7412.16 | 7412.16 | 5.4 | False | None | None | False | None | False | 40025.664 | 0 | 3872485 | 148441 | None | code07 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 7155.68 | 7155.68 | 1.71 | False | None | None | False | None | False | 12236.2128 | 0 | 3872486 | 148441 | None | code08 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Cable Km | 484.96 | 484.96 | 7.93 | False | None | None | False | None | False | 3845.7328 | 0 | 3872487 | 148441 | None | code09 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical sp ecifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:2:4 (M10) Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 6992.16 | 6992.16 | 6.12 | False | None | None | False | None | False | 42792.0192 | 0 | 3872488 | 148441 | None | code10 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 139106.24 | 139106.24 | 0.103 | False | None | None | False | None | False | 14327.94272 | 0 | 3872489 | 148441 | None | code11 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 1467.2 | 1467.2 | 146.22 | False | None | None | False | None | False | 214533.984 | 0 | 3872490 | 148441 | None | code12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 1236.48 | 1236.48 | 31.29 | False | None | None | False | None | False | 38689.4592 | 0 | 3872491 | 148441 | None | code13 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 12623.52 | 12623.52 | 7.07 | False | None | None | False | None | False | 89248.2864 | 0 | 3872492 | 148441 | None | code14 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 11496.24 | 11496.24 | 26.22 | False | None | None | False | None | False | 301431.4128 | 0 | 3872493 | 148441 | None | code15 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 11880.96 | 11880.96 | 9.99 | False | None | None | False | None | False | 118690.7904 | 0 | 3872494 | 148441 | None | code16 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Tonne | 100191.84 | 100191.84 | 3.869 | False | None | None | False | None | False | 387642.22896 | 0 | 3872495 | 148441 | None | code17 | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Kg | 204.96 | 204.96 | 640.71 | False | None | None | False | None | False | 131319.9216 | 0 | 3872496 | 148441 | None | code18 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 711.2 | 711.2 | 4.0 | False | None | None | False | None | False | 2844.8 | 0 | 3872497 | 148441 | None | code19 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 1593.76 | 1593.76 | 1.0 | False | None | None | False | None | False | 1593.76 | 0 | 3872498 | 148441 | None | code20 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Mtr | 271.04 | 271.04 | 48.0 | False | None | None | False | None | False | 13009.92 | 0 | 3872499 | 148441 | None | code21 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 415.52 | 415.52 | 339.6 | False | None | None | False | None | False | 141110.592 | 0 | 3872500 | 148441 | None | code22 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 285.6 | 285.6 | 205.98 | False | None | None | False | None | False | 58827.888 | 0 | 3872501 | 148441 | None | code23 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-ch with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 285.6 | 285.6 | 3.47 | False | None | None | False | None | False | 991.032 | 0 | 3872502 | 148441 | None | code24 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 1316.0 | 1316.0 | 145.27 | False | None | None | False | None | False | 191175.32 | 0 | 3872503 | 148441 | None | code25 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 995.68 | 995.68 | 2.83 | False | None | None | False | None | False | 2817.7744 | 0 | 3872504 | 148441 | None | code26 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. | Sqm | 7337.12 | 7337.12 | 27.45 | False | None | None | False | None | False | 201403.944 | 0 | 3872505 | 148441 | None | code27 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass,The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. | Sqm | 6994.4 | 6994.4 | 3.78 | False | None | None | False | None | False | 26438.832 | 0 | 3872506 | 148441 | None | code28 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessa with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 4467.68 | 4467.68 | 10.0 | False | None | None | False | None | False | 44676.8 | 0 | 3872507 | 148441 | None | code29 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 2761.92 | 2761.92 | 1.89 | False | None | None | False | None | False | 5220.0288 | 0 | 3872508 | 148441 | None | code30 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 6431.04 | 6431.04 | 4.51 | False | None | None | False | None | False | 29003.9904 | 0 | 3872509 | 148441 | None | code31 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with one side prelam with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 2284.8 | 2284.8 | 1.35 | False | None | None | False | None | False | 3084.48 | 0 | 3872510 | 148441 | None | code32 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Pan | 6694.24 | 6694.24 | 2.0 | False | None | None | False | None | False | 13388.48 | 0 | 3872511 | 148441 | None | code33 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 1366.4 | 1366.4 | 1.0 | False | None | None | False | None | False | 1366.4 | 0 | 3872512 | 148441 | None | code34 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Mtr | 460.32 | 460.32 | 6.0 | False | None | None | False | None | False | 2761.92 | 0 | 3872513 | 148441 | None | code35 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 75mm dia., 6 kg/sqcm & class 3 with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Mtr | 246.4 | 246.4 | 24.0 | False | None | None | False | None | False | 5913.6 | 0 | 3872514 | 148441 | None | code36 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 153.44 | 153.44 | 545.58 | False | None | None | False | None | False | 83713.7952 | 0 | 3872515 | 148441 | None | code37 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 155.68 | 155.68 | 61.76 | False | None | None | False | None | False | 9614.7968 | 0 | 3872516 | 148441 | None | code38 | Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 With Suitable size bends ,junction boxes adhesive paste etc and fixing using inverted wood plugsin case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Mtr | 68.0 | 68.0 | 100.0 | False | None | None | False | None | False | 6800.0 | 0 | 3872517 | 148441 | None | code39 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Mtr | 29.0 | 29.0 | 50.0 | False | None | None | False | None | False | 1450.0 | 0 | 3872518 | 148441 | None | code40 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TP with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Each | 802.0 | 802.0 | 4.0 | False | None | None | False | None | False | 3208.0 | 0 | 3872519 | 148441 | None | code41 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Each | 1492.0 | 1492.0 | 2.0 | False | None | None | False | None | False | 2984.0 | 0 | 3872520 | 148441 | None | code42 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 3510.0 | 3510.0 | 1.0 | False | None | None | False | None | False | 3510.0 | 0 | 3872521 | 148441 | None | code43 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work.a) 10-12 Way | Each | 319.0 | 319.0 | 8.0 | False | None | None | False | None | False | 2552.0 | 0 | 3872522 | 148441 | None | code44 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work.b) 3 Way | Each | 159.0 | 159.0 | 6.0 | False | None | None | False | None | False | 954.0 | 0 | 3872523 | 148441 | None | code45 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work.a) 10-12 Module | Each | 344.0 | 344.0 | 8.0 | False | None | None | False | None | False | 2752.0 | 0 | 3872524 | 148441 | None | code46 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work.b) 3 Module | Each | 161.0 | 161.0 | 6.0 | False | None | None | False | None | False | 966.0 | 0 | 3872525 | 148441 | None | code47 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6 with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work a) 16A UniversalSocket | Each | 236.0 | 236.0 | 27.0 | False | None | None | False | None | False | 6372.0 | 0 | 3872526 | 148441 | None | code48 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6 with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work.b) 16A One Way Switch | Each | 180.0 | 180.0 | 62.0 | False | None | None | False | None | False | 11160.0 | 0 | 3872527 | 148441 | None | code49 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6 with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work.c) Stepped Fan Regulator Two Module | Each | 357.0 | 357.0 | 4.0 | False | None | None | False | None | False | 1428.0 | 0 | 3872528 | 148441 | None | code50 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work.1.5 mm2 | Mtr | 26.0 | 26.0 | 450.0 | False | None | None | False | None | False | 11700.0 | 0 | 3872529 | 148441 | None | code51 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work.2.5 mm2 | Mtr | 42.0 | 42.0 | 360.0 | False | None | None | False | None | False | 15120.0 | 0 | 3872530 | 148441 | None | code52 | supplying of feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 x 2' - 9/10 W with all lead and lifts, loading and unloading charges and all other incidental charges etc for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work | Each | 551.0 | 551.0 | 5.0 | False | None | None | False | None | False | 2755.0 | 0 | 3872531 | 148441 | None | code53 | Supplying of recess mounting non integrated type LED down light W luminaire comprising of pressure decast/ extruded aluminium housing with spring loaded false ceiling clamps he operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 10-12W with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Each | 1269.0 | 1269.0 | 10.0 | False | None | None | False | None | False | 12690.0 | 0 | 3872532 | 148441 | None | code54 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.56" Sweep 5 Star (1400 mm) with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Each | 3754.0 | 3754.0 | 4.0 | False | None | None | False | None | False | 15016.0 | 0 | 3872533 | 148441 | None | code55 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Each | 2969.0 | 2969.0 | 1.0 | False | None | None | False | None | False | 2969.0 | 0 | 3872534 | 148441 | None | code56 | Supplying.litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 15 L with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Each | 8765.0 | 8765.0 | 1.0 | False | None | None | False | None | False | 8765.0 | 0 | 3872535 | 148441 | None | code57 | Supplying .TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit 2 Ton capacity with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Each | 54048.0 | 54048.0 | 2.0 | False | None | None | False | None | False | 108096.0 | 0 | 3872536 | 148441 | None | code58 | Cutting of Trees, excluding removal of stumps and roots of trees Girth above 1800 mm with all lead and lifts, loading and unloading charges and all other incidental charges etc., for successful completion of work as per specifications and as per the directions of the Engineer incharge of the work. | Each | 3968.16 | 3968.16 | 1.0 | False | None | None | False | None | False | 3968.16 | 0 |
|