1724920424000 | 0 | None | None | Buildings | Providing and Fixing Of Solar Panelling, Repair of Toilets, Renovation Of EE Chamber, Construction Of Flag Post, Repair Of Drinking Water and Solar Light and also construction Of Curb Stone in Mysore Town Panchayath Raj Engineering Division and Subdivision Office in Mysore(SC) | 1639099.74 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3877757 | 148833 | None | code01 | Demolishing brick work manually/ by mechanical means including stack- ing of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar | Cum | 1091.25 | 1091.25 | 3.33 | False | None | None | False | None | False | 3633.8625 | 0 | 3877758 | 148833 | None | code02 | Dismantling steel work in single sections including dismembering and stacking within to the appropriate disposal area as per direction of Engineer-in-charge..R.S. Joists. | Kg | 2.1 | 2.1 | 177.8 | False | None | None | False | None | False | 373.38 | 0 | 3877759 | 148833 | None | code03 | Dismantling tile work in floors and roofs laid in cement mortar includ- ing stacking material to the appropriate disposal area as per direction of Engineer-in-charge..For thickness of tiles 10 mm to 25 mm | Sqm | 50.4 | 50.4 | 41.55 | False | None | None | False | None | False | 2094.12 | 0 | 3877760 | 148833 | None | code04 | Demolishing R.C.C. work manually/ by mechanical means including stack- ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge | Cum | 2547.3 | 2547.3 | 1.759 | False | None | None | False | None | False | 4480.7007 | 0 | 3877761 | 148833 | None | code05 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m. | Cum | 254.1 | 254.1 | 3.14 | False | None | None | False | None | False | 797.874 | 0 | 3877762 | 148833 | None | code06 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Sqm | 1292.55 | 1292.55 | 37.8 | False | None | None | False | None | False | 48858.39 | 0 | 3877763 | 148833 | None | code07 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 0.7 | False | None | None | False | None | False | 4401.915 | 0 | 3877764 | 148833 | None | code08 | For Footing and Column Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications...Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6859.95 | 6859.95 | 1.15 | False | None | None | False | None | False | 7888.9425 | 0 | 3877765 | 148833 | None | code09 | For Plinth Beam Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications...Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9990.22 | 9990.22 | 0.33 | False | None | None | False | None | False | 3296.7726 | 0 | 3877766 | 148833 | None | code10 | Ground Floor Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 11.51 | False | None | None | False | None | False | 120190.2975 | 0 | 3877767 | 148833 | None | code11 | First Floor Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10546.67 | 10546.67 | 8.13 | False | None | None | False | None | False | 85744.4271 | 0 | 3877768 | 148833 | None | code12 | For Beam Slab Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11249.78 | 11249.78 | 1.64 | False | None | None | False | None | False | 18449.6392 | 0 | 3877769 | 148833 | None | code13 | Second Floor Lintel Beam Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 0.29 | False | None | None | False | None | False | 3028.2525 | 0 | 3877770 | 148833 | None | code14 | For Ground Floor Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 93929.85 | 93929.85 | 1.2661 | False | None | None | False | None | False | 118924.583085 | 0 | 3877771 | 148833 | None | code15 | For First Floor Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 94869.14 | 94869.14 | 0.9756 | False | None | None | False | None | False | 92554.332984 | 0 | 3877772 | 148833 | None | code16 | For Second Floor Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 95808.44 | 95808.44 | 0.1543 | False | None | None | False | None | False | 14783.242292 | 0 | 3877773 | 148833 | None | code17 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 158.5 | 158.5 | 12.96 | False | None | None | False | None | False | 2054.16 | 0 | 3877774 | 148833 | None | code18 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc | Sqm | 195.99 | 195.99 | 5.94 | False | None | None | False | None | False | 1164.1806 | 0 | 3877775 | 148833 | None | code19 | Ground Floor Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 17.55 | False | None | None | False | None | False | 21099.4875 | 0 | 3877776 | 148833 | None | code20 | For First Floor Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..Size of Tile 600x600 mm | Sqm | 1214.27 | 1214.27 | 53.23 | False | None | None | False | None | False | 64635.5921 | 0 | 3877777 | 148833 | None | code21 | Dismantling doors, windows and clerestory windows (steel or wood) shut- ter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge..Of area beyond 3 m² | Sqm | 277.85 | 277.85 | 1.89 | False | None | None | False | None | False | 525.1365 | 0 | 3877778 | 148833 | None | code22 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 8451.12 | 8451.12 | 0.43 | False | None | None | False | None | False | 3633.9816 | 0 | 3877779 | 148833 | None | code23 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 345.93 | 345.93 | 51.18 | False | None | None | False | None | False | 17704.6974 | 0 | 3877780 | 148833 | None | code24 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 146.72 | 146.72 | 5.64 | False | None | None | False | None | False | 827.5008 | 0 | 3877781 | 148833 | None | code25 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 303.09 | 303.09 | 54.24 | False | None | None | False | None | False | 16439.6016 | 0 | 3877782 | 148833 | None | code26 | Ground Floor Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete | Sqm | 1129.8 | 1129.8 | 28.45 | False | None | None | False | None | False | 32142.81 | 0 | 3877783 | 148833 | None | code27 | For Toilet in Second Floor Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete | Sqm | 1152.4 | 1152.4 | 11.94 | False | None | None | False | None | False | 13759.656 | 0 | 3877784 | 148833 | None | code28 | Ground Floor Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications | Sqm | 1461.6 | 1461.6 | 47.52 | False | None | None | False | None | False | 69455.232 | 0 | 3877785 | 148833 | None | code29 | For Toilet in Second Floor Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications | Sqm | 1490.83 | 1490.83 | 50.82 | False | None | None | False | None | False | 75763.9806 | 0 | 3877786 | 148833 | None | code30 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 g/m2 (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board | Sqm | 1215.33 | 1215.33 | 33.46 | False | None | None | False | None | False | 40664.9418 | 0 | 3877787 | 148833 | None | code31 | Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer- in-charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60 | Sqm | 1400.92 | 1400.92 | 33.46 | False | None | None | False | None | False | 46874.7832 | 0 | 3877788 | 148833 | None | code32 | Providing and fixing in wall lining flat pressed three layer (medium den- sity) particle board or graded wood Pre-laminated one side decorative lamination and other side balancing lamination Grade I, Type II, IS : 12823 marked, including priming coat on unexposed arrangement and screws etc. complete .25 mm thick | Sqm | 1789.06 | 1789.06 | 59.949 | False | None | None | False | None | False | 107252.35794 | 0 | 3877789 | 148833 | None | code33 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 | Nos | 680.08 | 680.08 | 10.0 | False | None | None | False | None | False | 6800.8 | 0 | 3877790 | 148833 | None | code34 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:. White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap | Nos | 2715.94 | 2715.94 | 8.0 | False | None | None | False | None | False | 21727.52 | 0 | 3877791 | 148833 | None | code35 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. .do- 30 mm thick one side teak and one side commercial. | Sqm | 3704.32 | 3704.32 | 5.67 | False | None | None | False | None | False | 21003.4944 | 0 | 3877792 | 148833 | None | code36 | Ground Floor Providing and fixing stainless steel Grade 304 railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature wherever required and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kgs | 599.18 | 599.18 | 219.42 | False | None | None | False | None | False | 131472.0756 | 0 | 3877793 | 148833 | None | code37 | For First Floor Providing and fixing stainless steel Grade 304 railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature wherever required and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kgs | 605.12 | 605.12 | 219.42 | False | None | None | False | None | False | 132775.4304 | 0 | 3877794 | 148833 | None | code38 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications | Kgs | 599.55 | 599.55 | 154.54 | False | None | None | False | None | False | 92654.457 | 0 | 3877795 | 148833 | None | code39 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS 12823 Grade l Type ll in panelling fixed in aluminum doors, windows shutters and partition frames with CP brass stainless steel screws etc. complete as per architectural drawings and directions of engineer in charge Prelaminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 1032.15 | 1032.15 | 7.86 | False | None | None | False | None | False | 8112.699 | 0 | 3877796 | 148833 | None | code40 | Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg / M | 142.8 | 142.8 | 160.709 | False | None | None | False | None | False | 22949.2452 | 0 | 3877797 | 148833 | None | code41 | Providing & fixing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m² | Sqm | 922.95 | 922.95 | 31.74 | False | None | None | False | None | False | 29294.433 | 0 | 3877798 | 148833 | None | code42 | Providing & fixing flat iron brackets 50x3 mm size with necessary bolts, nuts and washers etc. for fixing G.S. sheets gutters with purlins | Mtr | 77.7 | 77.7 | 6.6 | False | None | None | False | None | False | 512.82 | 0 | 3877799 | 148833 | None | code43 | Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components 21.1.2 50 LPH : Cabin Type Cabin Type Each 44000 | Each | 46200.0 | 46200.0 | 1.0 | False | None | None | False | None | False | 46200.0 | 0 | 3877800 | 148833 | None | code44 | Providing and fixing water closet indian type White vitreous china orissa pattern WC pan of size 580x440mm | Each | 5128.2 | 5128.2 | 4.0 | False | None | None | False | None | False | 20512.8 | 0 | 3877801 | 148833 | None | code45 | Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work Exposed on wall. 20 mm nominal dia Pipes | Mtr | 259.18 | 259.18 | 46.0 | False | None | None | False | None | False | 11922.28 | 0 | 3877802 | 148833 | None | code46 | Providing and fixing white vitreous china pedestal type water closet European type with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid | Each | 6275.85 | 6275.85 | 4.0 | False | None | None | False | None | False | 25103.4 | 0 | 3877803 | 148833 | None | code47 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required One urinal basin with 5 litre white P.V.C. automatic flushing cistern | Sqm | 4676.7 | 4676.7 | 4.0 | False | None | None | False | None | False | 18706.8 | 0 | 3877804 | 148833 | None | code48 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . Cost of aluminium snap beading shall be paid in basic item With float glass panes of 5 mm thickness weight not less than 12.50 kg/m² including cost of materials, labour, usage charges of machinery complete as per specifications | Sqm | 1229.55 | 1229.55 | 4.76 | False | None | None | False | None | False | 5852.658 | 0 |
|