1724828511000 | 0 | None | None | Buildings | Construction of building for officers and staff at SWM processing plant | 2517570.31 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3871331 | 148341 | None | code01 | Clearing & grubbing road land including vegetation, bushes,
shrubs, saplings by using weed cutter / minor equipment. pwd SR 23-24, vol 3CHAPTER 2 sl no 2.6 | Sqm | 357.0 | 357.0 | 100.0 | False | None | None | False | None | False | 35700.0 | 0 | 3871332 | 148341 | None | code02 | Earth work in surface excavation by mechanical means for lowering & leveling
the ground for all works other than foundation in all kinds of soils & upto depth
not exceeding 300mm as per drawing and technical specifications, including
setting out, shoring, strutting, barricading, caution lights, removal of stumps
and other deleterious matter including dressing of excavated surfaces, disposing
off or levelling the excavated earth or sorting & stacking the selected earth for
reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,
usage of machinery & other appurtenances required to complete the work.pwd SR 23-24, vol 1 I no 1.12 In all kinds of soils upto 300 mm depth | Cum | 99.75 | 99.75 | 30.0 | False | None | None | False | None | False | 2992.5 | 0 | 3871333 | 148341 | None | code03 | Providing and fixing factory made Green certified, Anti Termite, UV resistant,
high water absorbant single extruded WPC (Wood PolymerComposite) solid
plain flush door shutter of required size comprising of virgin polymer of
K value 58-60 (Suspension Grade), calcium carbonate and natural fibers
(wood powder/rice husk/wheat husk) and non toxic additives (maximum
toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and
screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum
compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and
resistance to spread of flame of Class A category with property of being
termite/borer proof, water/moisture proof and fire retardant and fixing
with stainless steel butt hinges of required size with necessary full body
threaded star headed counter sunk S.S screws The cost includes cost of
materials, transportation, labour and fixing charges..pwd SR 23-24, vol 2 item no 12.94.1. 30 mm thickness | Sqm | 3659.25 | 3659.25 | 80.0 | False | None | None | False | None | False | 292740.0 | 0 | 3871334 | 148341 | None | code04 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work. | Cum | 271.95 | 271.95 | 58.185 | False | None | None | False | None | False | 15823.41075 | 0 | 3871335 | 148341 | None | code05 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Bed concrete of mix 1:4:8PWD SR 2023-24 Volume-1 Page No. 15 I.No.2.1.3 | Cum | 6288.45 | 6288.45 | 13.6475 | False | None | None | False | None | False | 85821.621375 | 0 | 3871336 | 148341 | None | code06 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all aterials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- ( For footing) PWD SR 2023-24 Volume-1 Page No. 15 I.No.2.2.1 | Cum | 6601.35 | 6601.35 | 9.1125 | False | None | None | False | None | False | 60154.801875 | 0 | 3871337 | 148341 | None | code07 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all aterials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- ( For footing) PWD SR 2023-24 Volume-1 Page No. 15 I.No.2.2.1 Formwork 8% | Cum | 528.11 | 528.11 | 9.1125 | False | None | None | False | None | False | 4812.402375 | 0 | 3871338 | 148341 | None | code08 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (For coloumn) .(For coloumn) and shear wall PWD SR 2023-24 Volume-1 Page No. 16 I.No.2.4.2 | Cum | 6639.15 | 6639.15 | 1.459 | False | None | None | False | None | False | 9686.51985 | 0 | 3871339 | 148341 | None | code09 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (For coloumn) .(For coloumn) and shear wall PWD SR 2023-24 Volume-1 Page No. 16 I.No.2.4.2 Form work 8% | Cum | 531.13 | 531.13 | 1.4593 | False | None | None | False | None | False | 775.078009 | 0 | 3871340 | 148341 | None | code10 | Providing Random rubble masonry with hard stone in foundation and
plinth including levelling up with cement concrete 1:6:12 (1 cement : 6
coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth
level wit PWD SR 2023-24 Volume-2 Page No. 9 I.No.5.1.1 | Cum | 5891.55 | 5891.55 | 7.8156 | False | None | None | False | None | False | 46045.99818 | 0 | 3871341 | 148341 | None | code11 | Providing and constructing laterite size stone masonry including cost
and conveyance of all materials curing etc complete as per specification
I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for
saturated dry samples - For Basement in CM 1:6 PWD SR 2023-24 Volume-2 Page No. 9 I.No.5.6 | Cum | 6770.4 | 6770.4 | 8.5131 | False | None | None | False | None | False | 57637.09224 | 0 | 3871342 | 148341 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- (For plinth Beam) PWD SR 2023-24 Volume-1 Page No. 16 I.No.2.4.2 | Cum | 6639.15 | 6639.15 | 4.6023 | False | None | None | False | None | False | 30555.360045 | 0 | 3871343 | 148341 | None | code13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- (For plinth Beam) PWD SR 2023-24 Volume-1 Page No. 16 I.No.2.4.2 Formwork 50% | Cum | 3319.58 | 3319.58 | 4.6023 | False | None | None | False | None | False | 15277.703034 | 0 | 3871344 | 148341 | None | code14 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations
and other similar works etc. in layers not exceeding 20cm in depth, consolidating
each deposited layer by ramming and watering, lead up to 50 m and lift upto
1.5 m PWD SR 2023-24 Volume-1 Page No. 7 I.No.1.11 | Cum | 454.65 | 454.65 | 88.75 | False | None | None | False | None | False | 40350.1875 | 0 | 3871345 | 148341 | None | code15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- (For coloumns above plinth Beam ) PWD SR 2023-24 Volume-1 Page No. 16 I.No.2.5.1 | Cum | 6961.5 | 6961.5 | 2.3085 | False | None | None | False | None | False | 16070.62275 | 0 | 3871346 | 148341 | None | code16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- (For coloumns above plinth Beam ) PWD SR 2023-24 Volume-1 Page No. 16 I.No.2.5.1 Form work 70% | Cum | 4873.04 | 4873.04 | 2.3085 | False | None | None | False | None | False | 11249.41284 | 0 | 3871347 | 148341 | None | code17 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- (For Beams and lintle of Buildings) PWD SR 2023-24 Volume-1 Page No. 16 I.No.2.5.1 | Cum | 6961.5 | 6961.5 | 8.471 | False | None | None | False | None | False | 58970.8665 | 0 | 3871348 | 148341 | None | code18 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- (For Beams and lintle of Buildings) PWD SR 2023-24 Volume-1 Page No. 16 I.No.2.5.1 Form work 60% | Cum | 4176.9 | 4176.9 | 8.471 | False | None | None | False | None | False | 35382.5199 | 0 | 3871349 | 148341 | None | code19 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- (For chejja, staricase of Buildings) PWD SR 2023-24 Volume-1 Page No. 16 I.No.2.5.1 | Cum | 6961.5 | 6961.5 | 0.486 | False | None | None | False | None | False | 3383.289 | 0 | 3871350 | 148341 | None | code20 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- (For chejja, staricase of Buildings) PWD SR 2023-24 Volume-1 Page No. 16 I.No.2.5.1 Form work 45% | Cum | 3132.67 | 3132.67 | 0.486 | False | None | None | False | None | False | 1522.47762 | 0 | 3871351 | 148341 | None | code21 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- (For Roof Slab) PWD SR 2023-24 Volume-1 Page No. 16 I.No.2.5.1 | Cum | 6961.5 | 6961.5 | 15.625 | False | None | None | False | None | False | 108773.4375 | 0 | 3871352 | 148341 | None | code22 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- (For Roof Slab) PWD SR 2023-24 Volume-1 Page No. 16 I.No.2.5.1 Form work 50% | Cum | 3480.75 | 3480.75 | 15.625 | False | None | None | False | None | False | 54386.71875 | 0 | 3871353 | 148341 | None | code23 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification for buildings PWD CSR For 2023-24 Vol 1 Pag No:18 Item No. 2.11(a) | Tonne | 93929.85 | 93929.85 | 4.1456 | False | None | None | False | None | False | 389395.58616 | 0 | 3871354 | 148341 | None | code24 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specification PWD CSR For 2023-24 Vol 2 Pag No:17 Item No. 6.32 | Sqm | 1375.5 | 1375.5 | 138.255 | False | None | None | False | None | False | 190169.7525 | 0 | 3871355 | 148341 | None | code25 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. PWD CSR For 2023-24 Vol 2 Pag No:17 Item No. 6.34 | Sqm | 1159.2 | 1159.2 | 42.504 | False | None | None | False | None | False | 49270.6368 | 0 | 3871356 | 148341 | None | code26 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD CSR For 2023-24 Vol 2 Pag No:43 Item No. 8.10 | Sqm | 221.55 | 221.55 | 114.6315 | False | None | None | False | None | False | 25396.608825 | 0 | 3871357 | 148341 | None | code27 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD CSR For 2023-24 Vol 2 Pag No:41 Item No. 8.4.2 | Sqm | 327.6 | 327.6 | 202.4549 | False | None | None | False | None | False | 66324.22524 | 0 | 3871358 | 148341 | None | code28 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to
brick/stone masonry including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost of
materials, labour, curing complete as per specifications and as per direc tions of Engineer-in-charge PWD CSR For 2023-24 Vol 2 Pag No:41 Item No. 8.3.1 | Sqm | 371.7 | 371.7 | 210.78 | False | None | None | False | None | False | 78346.926 | 0 | 3871359 | 148341 | None | code29 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge PWD CSR For 2023-24 Vol 2 Pag No:50 Item No.8.51 | Sqm | 105.0 | 105.0 | 463.95 | False | None | None | False | None | False | 48714.75 | 0 | 3871360 | 148341 | None | code30 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CSR For 2023-24 Vol 2 Pag No:45 Item No. 8.27 & 8.28 | Sqm | 55.65 | 55.65 | 210.78 | False | None | None | False | None | False | 11729.907 | 0 | 3871361 | 148341 | None | code31 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CSR For 2023-24 Vol 2 Pag No:45 Item No. 8.27 & 8.28 | Sqm | 93.45 | 93.45 | 210.78 | False | None | None | False | None | False | 19697.391 | 0 | 3871362 | 148341 | None | code32 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.PWD CSR For 2023-24 Vol 2 Pag No:45 Item No. 8.25 | Sqm | 143.85 | 143.85 | 463.9499 | False | None | None | False | None | False | 66739.193115 | 0 | 3871363 | 148341 | None | code33 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth,costofmaterials,labourcompleteasperspecificationsandasper directions of Engineer-in-charge. PWD CSR For 2023-24 Vol 2 Pag No:48 Item No. 8.39 | Sqm | 133.35 | 133.35 | 221.58 | False | None | None | False | None | False | 29547.693 | 0 | 3871364 | 148341 | None | code34 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. PWD CSR For 2023-24 Vol 2 Pag No:86 Item No. 11.34.B | Kg | 192.15 | 192.15 | 339.885 | False | None | None | False | None | False | 65308.90275 | 0 | 3871365 | 148341 | None | code35 | Painting with synthetic enamel paint of approved brand and manufacture of equired colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of pproved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. PWD CSR For 2023-24 Vol 2 Pag No:48 Item No. 8.41 | Sqm | 175.35 | 175.35 | 14.835 | False | None | None | False | None | False | 2601.31725 | 0 | 3871366 | 148341 | None | code36 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. PWD CSR For 2023-24 Vol 2 Pag No:77 Item No.11.5.1 | Sqm | 4701.9 | 4701.9 | 5.67 | False | None | None | False | None | False | 26659.773 | 0 | 3871367 | 148341 | None | code37 | Providing fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made PWD CSR For 2023-24 Vol 2 Pag No:108 Item No.12.84 | Sqm | 5274.15 | 5274.15 | 13.635 | False | None | None | False | None | False | 71913.03525 | 0 | 3871368 | 148341 | None | code38 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. PWD CSR For 2023-24 Vol 2 Pag No:64 Item No.9.34 | Sqm | 1622.25 | 1622.25 | 48.5576 | False | None | None | False | None | False | 78772.5666 | 0 | 3871369 | 148341 | None | code39 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.PWD CSR For 2023-24 Vol 2 Pag No:60 Item No.9.9 | Sqm | 1129.8 | 1129.8 | 12.3001 | False | None | None | False | None | False | 13896.65298 | 0 | 3871370 | 148341 | None | code40 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete. PWD CSR For 2023-24 Vol 2 Pag No:71 Item No.10.14 | Sqm | 1161.3 | 1161.3 | 22.05 | False | None | None | False | None | False | 25606.665 | 0 | 3871371 | 148341 | None | code41 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC PWD CSR For 2023-24 Vol 2 Pag No:108 Item No.12.84 | Sqm | 5274.15 | 5274.15 | 13.635 | False | None | None | False | None | False | 71913.03525 | 0 | 3871372 | 148341 | None | code42 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4 mm C section or equivalent. The panel should consist of 3mm thick non halogenated FR grade mineral based polymer (2 hrs fire resist 0002 ance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete pwd sr 23-24, vol 2,item no 10.15.1. for straight portion | Sqm | 4188.45 | 4188.45 | 9.9 | False | None | None | False | None | False | 41465.655 | 0 | 3871373 | 148341 | None | code43 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.PWD Ele SR-2023-24 [P-2 NO-1.1.1]19/20 mm dia 2 mm thick | Rmtr | 72.45 | 72.45 | 120.0 | False | None | None | False | None | False | 8694.0 | 0 | 3871374 | 148341 | None | code44 | Supplying and drawing UTP-CAT 6E LAN cable...PWD Ele SR-2023-24 [P-35 I NO-8.1] | Rmtr | 39.9 | 39.9 | 100.0 | False | None | None | False | None | False | 3990.0 | 0 | 3871375 | 148341 | None | code45 | Supplying fixing retrofit type PL LED Lamp W LED linear source with CCT 6500 degree K, CRI 70percentage efficacy greater than 80 lumen per W life 25000 burning hours and Compliance to IS 10322 IEC 60598 LM 79 and LM 80 The LED are driven by HF electronic driver integrated in the system with PF 0.95 power loss should 5% of lamp Wage short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V.Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition Ele SR 2023-24 [P-43 I NO-11.2.2 ] 18-20 W | Rmtr | 737.1 | 737.1 | 15.0 | False | None | None | False | None | False | 11056.5 | 0 | 3871376 | 148341 | None | code46 | Supplying & fixing of I/O socket with back box Common SR 2023-24(P.No- 37 I no-8.10.2]Double I/O 8.10.2 | Each | 577.5 | 577.5 | 5.0 | False | None | None | False | None | False | 2887.5 | 0 | 3871377 | 148341 | None | code47 | Wiring for lighting/power circuit using one of FRLS PVC insulted 1.1 kV grade multi strand copper with low conductor resistance 2.5 Sqmm single core wire in open are concealed system of wiring with specified IS-694-1990 and conform into GTP of group A
Mtr p no 35 Part 1-SR 2023-24 2.5 mm2 p no 5 chapter-2 2.5mm2 2.3.3 | Rmtr | 44.1 | 44.1 | 200.0 | False | None | None | False | None | False | 8820.0 | 0 | 3871378 | 148341 | None | code48 | Wiring for lighting/power circuit using one of FRLS PVC insulted 1.1 kV grade multi strand copper with low conductor resistance 2.5 Sqmm single core wire in open are concealed system of wiring with specified IS-694-1990 and conform into GTP of group A
Mtr p no 35 Part 1-SR 2023-24 2.5 mm2 p no 5 chapter-2 1.5 mm2 2.3.2 | Rmtr | 27.3 | 27.3 | 100.0 | False | None | None | False | None | False | 2730.0 | 0 | 3871379 | 148341 | None | code49 | Wiring for lighting/power circuit using one of FRLS PVC insulted 1.1 kV grade multi strand copper with low conductor resistance 2.5 Sqmm single core wire in open are concealed system of wiring with specified IS-694-1990 and conform into GTP of group A
Mtr p no 35 Part 1-SR 2023-24 2.5 mm2 p no 5 chapter-2 4mm2 2.3.4 | Rmtr | 66.15 | 66.15 | 200.0 | False | None | None | False | None | False | 13230.0 | 0 | 3871380 | 148341 | None | code50 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required Confirming to IEC 60898 PWD Part 1-SR 2023-24 a) 6-32 A TPN (P.No-17 I no, 5.18.7] | Each | 1802.85 | 1802.85 | 6.0 | False | None | None | False | None | False | 10817.1 | 0 | 3871381 | 148341 | None | code51 | SupplyingofCeilingFanwithCapacitorratingAsperguidelineofBEE5starratingandIS:374/19andalsocomplywithIS:1709/1984withlatestamendment,Ratedvoltage220V/50Hz,Ratedpowerupto35W+/-0%,RatedcurrentAsperIS:374/19,Ratedpowerfactor0.9lagging(min),Ratedspeed350+/-10%RPM,Ratedairdelivery210+/-10%CubicMeterMinimum,Ratedservicevalue6.2CMM/W,ThreeBladesofbladeleaf1.05mmthickAluminiumAlloysheet,ClassBmotorinsulation,BearingTwoballbearings,Top6202,Bottom6201,asperISspecification,Motorwinding.TempriseShallnotexceed75degCoverandambientof400Cbyresistancemethodat245V,InsulationresistanceShallnotbelessthanTwoMegaOhms(2MOhms),LeakagecurrentShouldnotexceed210MicroAmp,Powerinput,W¤t,AirDelivery&FanSpeedasperIS:374/2019withlatestamendment,2yearmanufacturerWarranty.(BLDC fans) P.No- 30 I.no 6.4.1
48" Sweep 5 Star (1200 mm) | Each | 2810.85 | 2810.85 | 4.0 | False | None | None | False | None | False | 11243.4 | 0 | 3871382 | 148341 | None | code52 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.PWD Ele SR-2021-22 [P-5 I NO-3.4.5]8 Way | Each | 274.05 | 274.05 | 4.0 | False | None | None | False | None | False | 1096.2 | 0 | 3871383 | 148341 | None | code53 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.PWD Ele SR-2021-22 [P-5 I NO-3.4.5] 10-12 Way 3.4.6 | Each | 334.95 | 334.95 | 4.0 | False | None | None | False | None | False | 1339.8 | 0 | 3871384 | 148341 | None | code54 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.PWD Ele SR-2021-22 [P-5 I NO-3.4.5] -3 Way 3.4.2 | Each | 166.95 | 166.95 | 2.0 | False | None | None | False | None | False | 333.9 | 0 | 3871385 | 148341 | None | code55 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.PWD Ele SR-2023-24 [P-8 I NO 3.5.5
8 Module | Each | 298.2 | 298.2 | 4.0 | False | None | None | False | None | False | 1192.8 | 0 | 3871386 | 148341 | None | code56 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.PWD Ele SR-2023-24 [P-8
10-12 Module 3.5.6 | Each | 361.2 | 361.2 | 4.0 | False | None | None | False | None | False | 1444.8 | 0 | 3871387 | 148341 | None | code57 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.PWD Ele SR-2023-24 [P-8 1 to 3 Module 3.5.2 | Each | 169.05 | 169.05 | 2.0 | False | None | None | False | None | False | 338.1 | 0 | 3871388 | 148341 | None | code58 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PWD Common SR 2021-22 Page No-9 Item No-3.6 6A One Way Switch Page No-9 Item No-3.6.1 | Each | 107.1 | 107.1 | 60.0 | False | None | None | False | None | False | 6426.0 | 0 | 3871389 | 148341 | None | code59 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PWD Common SR 2021-22 Page No-9 Item No-3.6 6A Three Way socket Page No-9 Item No-3.6.3 | Each | 179.55 | 179.55 | 30.0 | False | None | None | False | None | False | 5386.5 | 0 | 3871390 | 148341 | None | code60 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PWD Common SR 2021-22 Page No-9 Item No-3.6 6/16A Universal Socket Page No-9 Item No-3.6.10 | Each | 247.8 | 247.8 | 4.0 | False | None | None | False | None | False | 991.2 | 0 | 3871391 | 148341 | None | code61 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PWD Common SR 2021-22 Page No-9 Item No-3.6 16A One Way SwitchPage No-9 Item No-3.6.7 | Each | 189.0 | 189.0 | 4.0 | False | None | None | False | None | False | 756.0 | 0 | 3871392 | 148341 | None | code62 | Supplying And Fixing Metal Fan Box with Round Hook. PWD Common SR 2021-22 Page No-4 Item No-1.13 | Each | 122.85 | 122.85 | 10.0 | False | None | None | False | None | False | 1228.5 | 0 | 3871393 | 148341 | None | code63 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293. PWD Common SR 2021-22 400W DimmerPage No-9 Item No-3.6.5 | Each | 289.8 | 289.8 | 6.0 | False | None | None | False | None | False | 1738.8 | 0 | 3871394 | 148341 | None | code64 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)without controlswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselength in a wood/PVC round block. complete for each outlet. PWD Common SR 2021-22 Short point upto 3Mtr from tapping point to out let via switch box.Page No-5 Item No-2.2.1 | Point | 282.45 | 282.45 | 8.0 | False | None | None | False | None | False | 2259.6 | 0 | 3871395 | 148341 | None | code65 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)without controlswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselength in a wood/PVC round block. complete for each outlet. PWD Common SR 2021-22
Mediumpointabove3Mtrupto6Mtrfromtappingpointtooutletviaswitch box.Page No-5 Item No-2.2.2 | Point | 397.95 | 397.95 | 10.0 | False | None | None | False | None | False | 3979.5 | 0 | 3871396 | 148341 | None | code66 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)without controlswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselength in a wood/PVC round block. complete for each outlet. PWD Common SR 2021-22 Longpointabove6Mtrupto10Mtrfromtappingpointtooutletviaswitch box.Page No-5 Item No-2.2.3 | Point | 582.75 | 582.75 | 8.0 | False | None | None | False | None | False | 4662.0 | 0 | 3871397 | 148341 | None | code67 | Earthing: Providing and fixing and wiring earth electrode for grounding
circuits IC cutouts and other equipments on the meter board in the pit.
The pits should be filled up with equal proportion of salt and charcoal
150mm around the pipe to complete depth. The connection from the
pipe to the conduits etc. is to established through GI wire of sizes as per
clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts,
the pipe shall have 16 through holes of 12mm dia..bwssb Common SR 2021-22 Page No-157 Item No-13.39 | Job | 3937.5 | 3937.5 | 1.0 | False | None | None | False | None | False | 3937.5 | 0 | 3871398 | 148341 | None | code68 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations
and cuts of pipes wherever necessary including jointing of PVC pipes
and specials (excluding cost of specials) with jointing of approved
type, with all labour with all lead & lift including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will make
his own arrangements for procuring water for testing) etc. complete For PVC pipes90mm dia., 6 kg/sqcm & class 3 pwd sr vol 5 i .no. 10.1.6 | Rmtr | 308.7 | 308.7 | 40.0 | False | None | None | False | None | False | 12348.0 | 0 | 3871399 | 148341 | None | code69 | Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, IS : 12701 marked, with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank. pwd sr vol 2 i .no.13.34 | Each | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 | 3871400 | 148341 | None | code70 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar
taps, 32 mm C.P. brass waste of standard pattern, including painting of
fittings and brackets, cutting and making good the walls wherever require:
14.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm
C.P. brass pillar taps pwd sr vol 2 i .no.14.7.1 | Each | 3236.1 | 3236.1 | 3.0 | False | None | None | False | None | False | 9708.3 | 0 | 3871401 | 148341 | None | code71 | Providing and fixing one piece construction white vitreous china squatting
plate with an integral longitudinal flushing pipe, white P.V.C. automatic
flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back
and front flush with standard spreader pipes with fittings, G.I clamps and
C.P. brass coupling complete, including painting of fittings and cutting and
making good the walls and floors etc. wherever required :
Single squatting plate with 5 litre P.V.C. automatic flushing cistern pwd sr vol 2 i .no.14.6.1 | Each | 6951.0 | 6951.0 | 2.0 | False | None | None | False | None | False | 13902.0 | 0 |
|