3880593 | 149012 | None | 1.4.1 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required tocomplete the work. In all kinds of soils Depth upto 1.5 m | Cum | 242.0 | 242.0 | 25.65 | False | None | None | False | None | False | 6207.3 | 0 |
3880594 | 149012 | None | 2.1.2 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 5664.0 | 5664.0 | 7.91 | False | None | None | False | None | False | 44802.24 | 0 |
3880595 | 149012 | None | 2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6998.4 | 6998.4 | 3.89 | False | None | None | False | None | False | 27223.776 | 0 |
3880596 | 149012 | None | 2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 11016.0 | 11016.0 | 3.7 | False | None | None | False | None | False | 40759.2 | 0 |
3880597 | 149012 | None | 2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 9720.0 | 9720.0 | 2.61 | False | None | None | False | None | False | 25369.2 | 0 |
3880598 | 149012 | None | 5.2 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand). | Cum | 6618.0 | 6618.0 | 14.17 | False | None | None | False | None | False | 93777.06 | 0 |
3880599 | 149012 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 266.0 | 266.0 | 25.65 | False | None | None | False | None | False | 6822.9 | 0 |
3880600 | 149012 | None | 1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials,usage& all other appurtenaces required to complete the work. | Cum | 474.0 | 474.0 | 35.36 | False | None | None | False | None | False | 16760.64 | 0 |
3880601 | 149012 | None | 2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 10368.0 | 10368.0 | 3.12 | False | None | None | False | None | False | 32348.16 | 0 |
3880602 | 149012 | None | 2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 9720.0 | 9720.0 | 7.66 | False | None | None | False | None | False | 74455.2 | 0 |
3880603 | 149012 | None | 2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 9396.0 | 9396.0 | 1.8 | False | None | None | False | None | False | 16912.8 | 0 |
3880604 | 149012 | None | 2.11(a) | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings. | Tonne | 89457.0 | 89457.0 | 1.824 | False | None | None | False | None | False | 163169.568 | 0 |
3880605 | 149012 | None | 6.7 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8211.0 | 8211.0 | 16.54 | False | None | None | False | None | False | 135809.94 | 0 |
3880606 | 149012 | None | 2.1.4 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite / trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6217.0 | 6217.0 | 1.69 | False | None | None | False | None | False | 10506.73 | 0 |
3880607 | 149012 | None | 8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin- charge. | Sqm | 323.0 | 323.0 | 127.6 | False | None | None | False | None | False | 41214.8 | 0 |
3880608 | 149012 | None | 8.3.2 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 333.0 | 333.0 | 95.65 | False | None | None | False | None | False | 31851.45 | 0 |
3880609 | 149012 | None | 12.12 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 124202.0 | 124202.0 | 0.103 | False | None | None | False | None | False | 12792.806 | 0 |
3880610 | 149012 | None | 12.18 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 6576.0 | 6576.0 | 2.04 | False | None | None | False | None | False | 13415.04 | 0 |
3880611 | 149012 | None | 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. | Kg | 168.0 | 168.0 | 109.82 | False | None | None | False | None | False | 18449.76 | 0 |
3880612 | 149012 | None | 11.10.1 | Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metalsash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 44.0 | 44.0 | 504.0 | False | None | None | False | None | False | 22176.0 | 0 |
3880613 | 149012 | None | 9.12.2 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm | Sqm | 1145.0 | 1145.0 | 50.1 | False | None | None | False | None | False | 57364.5 | 0 |
3880614 | 149012 | None | 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 100.0 | 100.0 | 127.6 | False | None | None | False | None | False | 12760.0 | 0 |
3880615 | 149012 | None | 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) | Sqm | 158.0 | 158.0 | 223.25 | False | None | None | False | None | False | 35273.5 | 0 |
3880616 | 149012 | None | 8.33.2 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 138.0 | 138.0 | 18.47 | False | None | None | False | None | False | 2548.86 | 0 |
3880617 | 149012 | None | 8.84 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete. | Each | 475.0 | 475.0 | 1.0 | False | None | None | False | None | False | 475.0 | 0 |
3880618 | 149012 | None | 1.2.1 | ELECTRIFICATION WORKS : Concealed Conduit System : Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 19/20 mm dia 2 mm thick | m | 66.0 | 66.0 | 8.0 | False | None | None | False | None | False | 528.0 | 0 |
3880619 | 149012 | None | 1.2.2 | Concealed Conduit System : Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 25 mm dia 2 mm thick | m | 78.0 | 78.0 | 6.0 | False | None | None | False | None | False | 468.0 | 0 |
3880620 | 149012 | None | 1.4.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 75 x 75 x 65 mm | Each | 106.0 | 106.0 | 1.0 | False | None | None | False | None | False | 106.0 | 0 |
3880621 | 149012 | None | 1.4.2 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 100 x 75 x 65 mm | Each | 118.0 | 118.0 | 1.0 | False | None | None | False | None | False | 118.0 | 0 |
3880622 | 149012 | None | 1.5.1 | Supplying and fixing PVC/metal conduit Deep junction box. 19/20 mm deep Junction box | Each | 49.0 | 49.0 | 1.0 | False | None | None | False | None | False | 49.0 | 0 |
3880623 | 149012 | None | 1.5.2 | Supplying and fixing PVC/metal conduit Deep junction box. 25 mm deep Junction box | Each | 56.0 | 56.0 | 1.0 | False | None | None | False | None | False | 56.0 | 0 |
3880624 | 149012 | None | 1.6.1 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 12" x 12" x 3" (300 x 300 x 76 mm) | Each | 120.0 | 120.0 | 1.0 | False | None | None | False | None | False | 120.0 | 0 |
3880625 | 149012 | None | 1.6.2 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 12" x 9" x 3" (300 x 300 x 76 mm) | Each | 115.0 | 115.0 | 1.0 | False | None | None | False | None | False | 115.0 | 0 |
3880626 | 149012 | None | 1.7.1 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall. | m | 29.0 | 29.0 | 10.0 | False | None | None | False | None | False | 290.0 | 0 |
3880627 | 149012 | None | 1.9.1 | Supplying PVC/GI flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 20 mm | m | 19.0 | 19.0 | 10.0 | False | None | None | False | None | False | 190.0 | 0 |
3880628 | 149012 | None | 1.9.2 | Supplying PVC/GI flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 20mm | m | 22.0 | 22.0 | 8.0 | False | None | None | False | None | False | 176.0 | 0 |
3880629 | 149012 | None | 1.9.3 | Supplying PVC/GI flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 32mm | m | 29.0 | 29.0 | 4.0 | False | None | None | False | None | False | 116.0 | 0 |
3880630 | 149012 | None | 2.1.1 | Point wiring using Copper wire with switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch. | Point | 285.0 | 285.0 | 6.0 | False | None | None | False | None | False | 1710.0 | 0 |
3880631 | 149012 | None | 2.1.2 | Point wiring using Copper wire with switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch. | Point | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 |
3880632 | 149012 | None | 2.1.3 | Point wiring using Copper wire with switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch. | Point | 570.0 | 570.0 | 2.0 | False | None | None | False | None | False | 1140.0 | 0 |
3880633 | 149012 | None | 2.3.1 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1sqmm | m | 19.0 | 19.0 | 10.0 | False | None | None | False | None | False | 190.0 | 0 |
3880634 | 149012 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5sqmm | m | 26.0 | 26.0 | 10.0 | False | None | None | False | None | False | 260.0 | 0 |
3880635 | 149012 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5sqmm | m | 42.0 | 42.0 | 8.0 | False | None | None | False | None | False | 336.0 | 0 |
3880636 | 149012 | None | 3.1.1 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654. 6A 2 Way. | Each | 128.0 | 128.0 | 1.0 | False | None | None | False | None | False | 128.0 | 0 |
3880637 | 149012 | None | 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2 Way | Each | 138.0 | 138.0 | 1.0 | False | None | None | False | None | False | 138.0 | 0 |
3880638 | 149012 | None | 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5 Way | Each | 177.0 | 177.0 | 1.0 | False | None | None | False | None | False | 177.0 | 0 |
3880639 | 149012 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 102.0 | 102.0 | 2.0 | False | None | None | False | None | False | 204.0 | 0 |
3880640 | 149012 | None | 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way Switch | Each | 166.0 | 166.0 | 1.0 | False | None | None | False | None | False | 166.0 | 0 |
3880641 | 149012 | None | 3.6.7 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch | Each | 180.0 | 180.0 | 1.0 | False | None | None | False | None | False | 180.0 | 0 |
3880642 | 149012 | None | 3.6.5 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 400W Dimmer | Each | 276.0 | 276.0 | 1.0 | False | None | None | False | None | False | 276.0 | 0 |
3880643 | 149012 | None | 3.12.1 | Supplying .way plastic gang box and fixing using necessary wooden/ rawl/phill plugs and screws. 1 Way Gang Box | No | 23.0 | 23.0 | 1.0 | False | None | None | False | None | False | 23.0 | 0 |
3880644 | 149012 | None | 3.12.2 | Supplying .way plastic gang box and fixing using necessary wooden/ rawl/phill plugs and screws. 2 to 4 Way Gang Box | No | 32.0 | 32.0 | 1.0 | False | None | None | False | None | False | 32.0 | 0 |
3880645 | 149012 | None | 5.19.1 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I - Single Door 4 Way SP & N | Each | 1241.0 | 1241.0 | 1.0 | False | None | None | False | None | False | 1241.0 | 0 |
3880646 | 149012 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model. | Each | 2984.0 | 2984.0 | 1.0 | False | None | None | False | None | False | 2984.0 | 0 |
3880647 | 149012 | None | 11.2.1 | Supplying & fixing retrofit type-PL- LED Lamp . W LED linear source with CCT 6500 degree K, CRI less than 70%. efficacy less than 80 lumen per W, life less than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF less than 0.95, power loss should greater than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 8-9 W | Each | 623.0 | 623.0 | 2.0 | False | None | None | False | None | False | 1246.0 | 0 |
3880648 | 149012 | None | 13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 2.0 | False | None | None | False | None | False | 244.0 | 0 |
3880649 | 149012 | None | 13.11 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 315.0 | 315.0 | 1.0 | False | None | None | False | None | False | 315.0 | 0 |
3880650 | 149012 | None | 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GIpipe 2.5m long buried in a pit. The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 3510.0 | 3510.0 | 1.0 | False | None | None | False | None | False | 3510.0 | 0 |