tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1724939456000 | 0 | None | None | Buildings | Civil | 4931453.06 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3882114 | 149090 | None | code01 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering and leveling the ground for all works other than foundation and depth in all kinds of soil not exceeding 300mm as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work. | Cum | 95.55 | 95.55 | 70.525 | False | None | None | False | None | False | 6738.66375 | 0 | 3882115 | 149090 | None | code02 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifcations,including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 313.95 | 313.95 | 133.85 | False | None | None | False | None | False | 42022.2075 | 0 | 3882116 | 149090 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 23.76 | False | None | None | False | None | False | 155101.716 | 0 | 3882117 | 149090 | None | code04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticizers laid in fnished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement and formwork to be paid separately) (PWDSR 2021-22 Vol-1 P.No.16 I.No.2.2.1.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7518.42 | 7518.42 | 12.62 | False | None | None | False | None | False | 94882.4604 | 0 | 3882118 | 149090 | None | code05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticizers laid in fnished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement and formwork to be paid separately) (PWDSR 2021-22 Vol-1 P.No.16 I.No.2.2.1.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11834.55 | 11834.55 | 3.74 | False | None | None | False | None | False | 44261.217 | 0 | 3882119 | 149090 | None | code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars and formwork to be paid separately)(PWDSR 2021-22 Vol-1 P.No.17 I.No.2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11834.55 | 11834.55 | 9.63 | False | None | None | False | None | False | 113966.7165 | 0 | 3882120 | 149090 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 24.46 | False | None | None | False | None | False | 255417.435 | 0 | 3882121 | 149090 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 43.46 | False | None | None | False | None | False | 453820.185 | 0 | 3882122 | 149090 | None | code09 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand :12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 47.34 | False | None | None | False | None | False | 278905.977 | 0 | 3882123 | 149090 | None | code10 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand | Cum | 6515.25 | 6515.25 | 28.07 | False | None | None | False | None | False | 182883.0675 | 0 | 3882124 | 149090 | None | code11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 164.85 | False | None | None | False | None | False | 46042.605 | 0 | 3882125 | 149090 | None | code12 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement and formwork shall be paid separately) | Cum | 6527.85 | 6527.85 | 23.66 | False | None | None | False | None | False | 154448.931 | 0 | 3882126 | 149090 | None | code13 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifcations. --do-- Honne wood frames. | Cum | 144977.7 | 144977.7 | 0.96 | False | None | None | False | None | False | 139178.592 | 0 | 3882127 | 149090 | None | code14 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9317.7 | 9317.7 | 69.21 | False | None | None | False | None | False | 644878.017 | 0 | 3882128 | 149090 | None | code15 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 93929.85 | 93929.85 | 8.2 | False | None | None | False | None | False | 770224.77 | 0 | 3882129 | 149090 | None | code16 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fne sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 586.24 | False | None | None | False | None | False | 181587.84 | 0 | 3882130 | 149090 | None | code17 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) fnished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fne sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 568.2 | False | None | None | False | None | False | 221342.31 | 0 | 3882131 | 149090 | None | code18 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings /wooden frames
with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 876.96 | False | None | None | False | None | False | 168507.864 | 0 | 3882132 | 149090 | None | code19 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi
chambered UPVC(Matching to RAL-9016) sections and with minimum
TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and
lead free, gaskets -grey color having isolated drainage and reinforced with
Galvanized Iron profile through-out the window frame. The outer frame
having an overall size of 44mm width x 40mmheight with reinforcement
of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC | Sqm | 5274.15 | 5274.15 | 30.24 | False | None | None | False | None | False | 159490.296 | 0 | 3882133 | 149090 | None | code20 | Providing and fxing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifcations. (excluding cost of fxtures) | Sqm | 7816.2 | 7816.2 | 20.16 | False | None | None | False | None | False | 157574.592 | 0 | 3882134 | 149090 | None | code21 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 586.24 | False | None | None | False | None | False | 84330.624 | 0 | 3882135 | 149090 | None | code22 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied at 2.20kg/10 sqm to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge | Sqm | 297.15 | 297.15 | 568.2 | False | None | None | False | None | False | 168840.63 | 0 | 3882136 | 149090 | None | code23 | Providing and laying Polished Glazed Vitrified tiles with thickness 10
mm in floor with different sizes with water absorption less than 0.08%
and conforming to IS:15622, of approved brand & manufacturer, in all
colours and shade, laid with cement based high polymer modified quick
set tile adhesive (water based) conforming to IS : 15477, in average 6 mm
thickness, including grouting of joints (Payment for grouting of joints to
be made separately).Size of Tile 600x600 mm | Sqm | 1392.3 | 1392.3 | 247.73 | False | None | None | False | None | False | 344914.479 | 0 | 3882137 | 149090 | None | code24 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifcations. | Sqm | 1521.45 | 1521.45 | 18.26 | False | None | None | False | None | False | 27781.677 | 0 | 3882138 | 149090 | None | code25 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied at 0.90 ltr/10 sqm over an under coat of primer applied at0.75 ltr/10 sqm of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 144.9 | 144.9 | 45.36 | False | None | None | False | None | False | 6572.664 | 0 | 3882139 | 149090 | None | code26 | Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals at1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts and 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure at equal intervals including cutting, welding, bending wherever necessary with suitable caps at tops, bottoms and corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged | Kg | 595.35 | 595.35 | 31.5 | False | None | None | False | None | False | 18753.525 | 0 | 3882140 | 149090 | None | code27 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: 110mm dia 6kg/sqcm | Mtr | 271.0 | 271.0 | 12.0 | False | None | None | False | None | False | 3252.0 | 0 | 3882141 | 149090 | None | code28 | Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete.125x70x4 mm (ordinary type) | Each | 151.0 | 151.0 | 8.0 | False | None | None | False | None | False | 1208.0 | 0 | 3882142 | 149090 | None | code29 | Hold fasts | Each | 32.0 | 32.0 | 16.0 | False | None | None | False | None | False | 512.0 | 0 | 3882143 | 149090 | None | code30 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete 125mm | Each | 30.0 | 30.0 | 8.0 | False | None | None | False | None | False | 240.0 | 0 | 3882144 | 149090 | None | code31 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Each | 832.0 | 832.0 | 4.0 | False | None | None | False | None | False | 3328.0 | 0 | 3882145 | 149090 | None | code32 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. | Each | 111.0 | 111.0 | 4.0 | False | None | None | False | None | False | 444.0 | 0 |
| 1724939456000 | 0 | None | None | Buildings | electrical | 118626.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3882146 | 149091 | None | code01 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required.25mm | Mtr | 28.0 | 28.0 | 180.0 | False | None | None | False | None | False | 5040.0 | 0 | 3882147 | 149091 | None | code02 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete.4"x4"x3" ( 101x101x76mm) | Each | 69.0 | 69.0 | 24.0 | False | None | None | False | None | False | 1656.0 | 0 | 3882148 | 149091 | None | code03 | I. Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVCConduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Using class A Materials b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 386.0 | 386.0 | 12.0 | False | None | None | False | None | False | 4632.0 | 0 | 3882149 | 149091 | None | code04 | c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Point | 567.0 | 567.0 | 12.0 | False | None | None | False | None | False | 6804.0 | 0 | 3882150 | 149091 | None | code05 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5 sqmm | Mtr | 26.0 | 26.0 | 300.0 | False | None | None | False | None | False | 7800.0 | 0 | 3882151 | 149091 | None | code06 | do 2.5 sqmm | Mtr | 40.0 | 40.0 | 45.0 | False | None | None | False | None | False | 1800.0 | 0 | 3882152 | 149091 | None | code07 | do 4 sqmm | Mtr | 59.0 | 59.0 | 200.0 | False | None | None | False | None | False | 11800.0 | 0 | 3882153 | 149091 | None | code08 | Supplying and flush mounting powder coated / galvanized
metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way | Each | 123.0 | 123.0 | 9.0 | False | None | None | False | None | False | 1107.0 | 0 | 3882154 | 149091 | None | code09 | do 8Way | Each | 250.0 | 250.0 | 3.0 | False | None | None | False | None | False | 750.0 | 0 | 3882155 | 149091 | None | code10 | do 10-12Way | Each | 325.0 | 325.0 | 15.0 | False | None | None | False | None | False | 4875.0 | 0 | 3882156 | 149091 | None | code11 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. Group-A 1 to 3 Module | Each | 152.0 | 152.0 | 9.0 | False | None | None | False | None | False | 1368.0 | 0 | 3882157 | 149091 | None | code12 | do 8Moudule | Each | 302.0 | 302.0 | 3.0 | False | None | None | False | None | False | 906.0 | 0 | 3882158 | 149091 | None | code13 | do 12Moudule | Each | 403.0 | 403.0 | 6.0 | False | None | None | False | None | False | 2418.0 | 0 | 3882159 | 149091 | None | code14 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 6Amps one way. | Each | 88.0 | 88.0 | 48.0 | False | None | None | False | None | False | 4224.0 | 0 | 3882160 | 149091 | None | code15 | do Stepped Fan Regulator. | Each | 313.0 | 313.0 | 6.0 | False | None | None | False | None | False | 1878.0 | 0 | 3882161 | 149091 | None | code16 | do 16Amps one way switch | Each | 249.0 | 249.0 | 18.0 | False | None | None | False | None | False | 4482.0 | 0 | 3882162 | 149091 | None | code17 | do 32Amps DP switch | Each | 375.0 | 375.0 | 6.0 | False | None | None | False | None | False | 2250.0 | 0 | 3882163 | 149091 | None | code18 | do 6/16Amps universal socket | Each | 249.0 | 249.0 | 12.0 | False | None | None | False | None | False | 2988.0 | 0 | 3882164 | 149091 | None | code19 | do 6Amps 3way socket. | Each | 162.0 | 162.0 | 12.0 | False | None | None | False | None | False | 1944.0 | 0 | 3882165 | 149091 | None | code20 | Supplying of ..feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70 percent lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than0.9 along with CE approved. years Warranty against any manufacturing defect working under standard electrical condition.12.3.2 LED light fitting 1 x 4'- 20/22 w Each LED light fitting 1 x 4'- 20/22 w Each | Each | 740.0 | 740.0 | 11.0 | False | None | None | False | None | False | 8140.0 | 0 | 3882166 | 149091 | None | code21 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts,bolts and
washers.32Amps | Each | 200.0 | 200.0 | 3.0 | False | None | None | False | None | False | 600.0 | 0 | 3882167 | 149091 | None | code22 | Supplying and fixing regular MCB distribution boards on
wall/ood board / flush mounting using required clA, bolts,
nuts etc., with provision for fixing suitable type capacity
MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.a) 6-32Amps SP Group 'A' | Each | 523.0 | 523.0 | 3.0 | False | None | None | False | None | False | 1569.0 | 0 | 3882168 | 149091 | None | code23 | 6-32 Amps DP Group 'A' | Each | 1103.0 | 1103.0 | 3.0 | False | None | None | False | None | False | 3309.0 | 0 | 3882169 | 149091 | None | code24 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door a) 4Way SP &N | Each | 1368.0 | 1368.0 | 3.0 | False | None | None | False | None | False | 4104.0 | 0 | 3882170 | 149091 | None | code25 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg HESCOM SR | No | 770.0 | 770.0 | 3.0 | False | None | None | False | None | False | 2310.0 | 0 | 3882171 | 149091 | None | code26 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each HESCOM SR | No | 660.0 | 660.0 | 3.0 | False | None | None | False | None | False | 1980.0 | 0 | 3882172 | 149091 | None | code27 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag HESCOM SR | Bag | 303.0 | 303.0 | 3.0 | False | None | None | False | None | False | 909.0 | 0 | 3882173 | 149091 | None | code28 | Digging of Pit for providing GI Pipe type Earthing LABOUR RATE HESCOM SR Hard Soil | Per Pit | 2267.0 | 2267.0 | 3.0 | False | None | None | False | None | False | 6801.0 | 0 | 3882174 | 149091 | None | code29 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system and as per technical data approved.48" Sweep (1200mm) Regular model | Each | 2085.0 | 2085.0 | 8.0 | False | None | None | False | None | False | 16680.0 | 0 | 3882175 | 149091 | None | code30 | Supply and fixing polished wood board made of not less
than 15mm thick plank on both sides of not more than 2
pieces and fixing the same to the wall using tapered inverted wooden plugs screws.8"x6"1.5" | Each | 76.0 | 76.0 | 3.0 | False | None | None | False | None | False | 228.0 | 0 | 3882176 | 149091 | None | code31 | do 12"x12"2" | Each | 162.0 | 162.0 | 3.0 | False | None | None | False | None | False | 486.0 | 0 | 3882177 | 149091 | None | code32 | Fixing all types and all capacities of fluorescent /false ceiling /spot light / CFL / LED fittings indoor on the wall/ ceiling /rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.On wall / ceiling / Rafter / Girders | Each | 119.0 | 119.0 | 8.0 | False | None | None | False | None | False | 952.0 | 0 | 3882178 | 149091 | None | code33 | Fixing a ceiling /wall mounting fan of all capacities and all
types, with necessary clA and 'S' hook made out of 15mm dia
MS rod, with 5 A. ceiling rose of approved quality with
necessary length of 23/0.0076 inch PVC insulated twin twisted
wire of approved quality, mounted on a suitable size wooden
board and wired. | Each | 281.0 | 281.0 | 6.0 | False | None | None | False | None | False | 1686.0 | 0 | 3882179 | 149091 | None | code34 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 20mm Point wiring using Copper wire with switch. | Mtr | 25.0 | 25.0 | 6.0 | False | None | None | False | None | False | 150.0 | 0 |
| 1724939456000 | 0 | None | None | Buildings | Girls Toilet | 341970.91 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3882180 | 149092 | None | code01 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering and leveling the ground for all works other than foundation and depth in all kinds of soil not exceeding 300mm as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work. | Cum | 91.0 | 91.0 | 1.8 | False | None | None | False | None | False | 163.8 | 0 | 3882181 | 149092 | None | code02 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifcations,including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 299.0 | 299.0 | 11.7 | False | None | None | False | None | False | 3498.3 | 0 | 3882182 | 149092 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6217.0 | 6217.0 | 1.87 | False | None | None | False | None | False | 11625.79 | 0 | 3882183 | 149092 | None | code04 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10608.0 | 10608.0 | 1.21 | False | None | None | False | None | False | 12835.68 | 0 | 3882184 | 149092 | None | code05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars and formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9945.0 | 9945.0 | 2.21 | False | None | None | False | None | False | 21978.45 | 0 | 3882185 | 149092 | None | code06 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand :12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5611.0 | 5611.0 | 5.73 | False | None | None | False | None | False | 32151.03 | 0 | 3882186 | 149092 | None | code07 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 266.0 | 266.0 | 1.9 | False | None | None | False | None | False | 505.4 | 0 | 3882187 | 149092 | None | code08 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement and formwork shall be paid separately) | Cum | 6217.0 | 6217.0 | 1.31 | False | None | None | False | None | False | 8144.27 | 0 | 3882188 | 149092 | None | code09 | Fixing of door frame in an existing opening including embedding frame in
floor and walls after cutting masonry for holdfasts for embedding holdfast
in cement concrete 1:3:6 of 20mm and down size granite metal painting
two coats of coal tar to sides of frame, making good the damages to walls
and floor as required and disposal of the debris with lead upto 50 m.
including cost of materials, labour charges, complete as per specifications. | No | 1016.0 | 1016.0 | 3.0 | False | None | None | False | None | False | 3048.0 | 0 | 3882189 | 149092 | None | code10 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work | Cum | 8874.0 | 8874.0 | 11.55 | False | None | None | False | None | False | 102494.7 | 0 | 3882190 | 149092 | None | code11 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifcations. (The laps and wastages shall not be measured separately) | Tonne | 89457.0 | 89457.0 | 0.2686 | False | None | None | False | None | False | 24028.1502 | 0 | 3882191 | 149092 | None | code12 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fne sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 295.0 | 295.0 | 44.61 | False | None | None | False | None | False | 13159.95 | 0 | 3882192 | 149092 | None | code13 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) fnished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fne sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 371.0 | 371.0 | 36.48 | False | None | None | False | None | False | 13534.08 | 0 | 3882193 | 149092 | None | code14 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings /wooden frames
with rawl plugs screws etc. | Kg | 183.0 | 183.0 | 14.58 | False | None | None | False | None | False | 2668.14 | 0 | 3882194 | 149092 | None | code15 | Providing and fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top and bottom rails, covered with heat moulded
PVC C channel of 5mm thick sheet and 30 x 50mm wide to form stiles and 5mm thick and 75mm wide PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick 20mm wide PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles and rails with 5x30mm PVC sheet beading on either side and joined together with solvent cement adhesive etc., Complete as per manufacturers specification and direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges. | Sqm | 1588.0 | 1588.0 | 5.67 | False | None | None | False | None | False | 9003.96 | 0 | 3882195 | 149092 | None | code16 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 137.0 | 137.0 | 33.69 | False | None | None | False | None | False | 4615.53 | 0 | 3882196 | 149092 | None | code17 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr/10 m²) over and including priming coat of exterior primer applied at 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge | Sqm | 283.0 | 283.0 | 36.48 | False | None | None | False | None | False | 10323.84 | 0 | 3882197 | 149092 | None | code18 | Providing and laying Polished Glazed Vitrified tiles with thickness 10
mm in floor with different sizes with water absorption less than 0.08%
and conforming to IS:15622, of approved brand & manufacturer, in all
colours and shade, laid with cement based high polymer modified quick
set tile adhesive (water based) conforming to IS : 15477, in average 6 mm
thickness, including grouting of joints (Payment for grouting of joints to
be made separately) Size of Tile 600x600 mm | Sqm | 1326.0 | 1326.0 | 8.08 | False | None | None | False | None | False | 10714.08 | 0 | 3882198 | 149092 | None | code19 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifcations. | Sqm | 1449.0 | 1449.0 | 6.24 | False | None | None | False | None | False | 9041.76 | 0 | 3882199 | 149092 | None | code20 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required:
14.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests | No | 106.0 | 106.0 | 2.0 | False | None | None | False | None | False | 212.0 | 0 | 3882200 | 149092 | None | code21 | Providing and fixing white vitreous china flat back half stall urinal
of size 580x380x350 mm with white PVC automatic flushing cistern,
with fittings, standard size C.P. brass flush pipe, spreaders with unions
and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap
with outlet grating and other couplings in C.P. brass, including painting
of fittings and cutting and making good the walls and floors wherever
required :
14.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern | No | 8642.0 | 8642.0 | 3.0 | False | None | None | False | None | False | 25926.0 | 0 | 3882201 | 149092 | None | code22 | Providing and fxing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fttings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | No | 3082.0 | 3082.0 | 1.0 | False | None | None | False | None | False | 3082.0 | 0 | 3882202 | 149092 | None | code23 | Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 1000 litre capacity) | Ltr | 9.0 | 9.0 | 1000.0 | False | None | None | False | None | False | 9000.0 | 0 | 3882203 | 149092 | None | code24 | Providing and fixing brass bib cock of approved quality | No | 326.0 | 326.0 | 5.0 | False | None | None | False | None | False | 1630.0 | 0 | 3882204 | 149092 | None | code25 | Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this including the pipe with clamp at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete .(internal work exposed on wall) 25mm nominal OD Pipe | Mtr | 477.0 | 477.0 | 18.0 | False | None | None | False | None | False | 8586.0 | 0 |
| 1724939456000 | 0 | None | None | Buildings | Boys Toilet | 341831.27 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3882205 | 149093 | None | code01 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering and leveling the ground for all works other than foundation and depth in all kinds of soil not exceeding 300mm as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work. | Cum | 91.0 | 91.0 | 1.8 | False | None | None | False | None | False | 163.8 | 0 | 3882206 | 149093 | None | code02 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifcations,including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 299.0 | 299.0 | 12.3 | False | None | None | False | None | False | 3677.7 | 0 | 3882207 | 149093 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement and formwork shall be paid separately) (PWDSR 2021-22 Vol-1 P.No.15 I.No. 2.1.3) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6217.0 | 6217.0 | 2.02 | False | None | None | False | None | False | 12558.34 | 0 | 3882208 | 149093 | None | code04 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10608.0 | 10608.0 | 0.96 | False | None | None | False | None | False | 10183.68 | 0 | 3882209 | 149093 | None | code05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9945.0 | 9945.0 | 1.84 | False | None | None | False | None | False | 18298.8 | 0 | 3882210 | 149093 | None | code06 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand :12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5611.0 | 5611.0 | 4.64 | False | None | None | False | None | False | 26035.04 | 0 | 3882211 | 149093 | None | code07 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 266.0 | 266.0 | 1.9 | False | None | None | False | None | False | 505.4 | 0 | 3882212 | 149093 | None | code08 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement and formwork shall be paid separately) | Cum | 6217.0 | 6217.0 | 0.65 | False | None | None | False | None | False | 4041.05 | 0 | 3882213 | 149093 | None | code09 | Fixing of door frame in an existing opening including embedding frame in
floor and walls after cutting masonry for holdfasts for embedding holdfast
in cement concrete 1:3:6 of 20mm and down size granite metal painting
two coats of coal tar to sides of frame, making good the damages to walls
and floor as required and disposal of the debris with lead upto 50 m.
including cost of materials, labour charges, complete as per specifications. | No | 1016.0 | 1016.0 | 5.0 | False | None | None | False | None | False | 5080.0 | 0 | 3882214 | 149093 | None | code10 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work | Cum | 8874.0 | 8874.0 | 13.19 | False | None | None | False | None | False | 117048.06 | 0 | 3882215 | 149093 | None | code11 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifcations. (The laps and wastages shall not be measured separately) | Tonne | 89457.0 | 89457.0 | 0.178 | False | None | None | False | None | False | 15923.346 | 0 | 3882216 | 149093 | None | code12 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fne sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 295.0 | 295.0 | 76.41 | False | None | None | False | None | False | 22540.95 | 0 | 3882217 | 149093 | None | code13 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) fnished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fne sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 371.0 | 371.0 | 36.48 | False | None | None | False | None | False | 13534.08 | 0 | 3882218 | 149093 | None | code14 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings /wooden frames
with rawl plugs screws etc. | Kg | 183.0 | 183.0 | 14.58 | False | None | None | False | None | False | 2668.14 | 0 | 3882219 | 149093 | None | code15 | Providing and fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top and bottom rails, covered with heat moulded
PVC C channel of 5mm thick sheet and 30 x 50mm wide to form stiles and 5mm thick and 75mm wide PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick 20mm wide PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles and rails with 5x30mm PVC sheet beading on either side and joined together with solvent cement adhesive etc., Complete as per manufacturers specification and direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges. | Sqm | 1588.0 | 1588.0 | 9.45 | False | None | None | False | None | False | 15006.6 | 0 | 3882220 | 149093 | None | code16 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 137.0 | 137.0 | 67.38 | False | None | None | False | None | False | 9231.06 | 0 | 3882221 | 149093 | None | code17 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr/10 m²) over and including priming coat of exterior primer applied at 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge | Sqm | 283.0 | 283.0 | 36.48 | False | None | None | False | None | False | 10323.84 | 0 | 3882222 | 149093 | None | code18 | Providing and laying Polished Glazed Vitrified tiles with thickness 10
mm in floor with different sizes with water absorption less than 0.08%
and conforming to IS:15622, of approved brand & manufacturer, in all
colours and shade, laid with cement based high polymer modified quick
set tile adhesive (water based) conforming to IS : 15477, in average 6 mm
thickness, including grouting of joints (Payment for grouting of joints to
be made separately).9.22.2 Size of Tile 600x600 mm | Sqm | 1326.0 | 1326.0 | 7.03 | False | None | None | False | None | False | 9321.78 | 0 | 3882223 | 149093 | None | code19 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifcations. | Sqm | 1449.0 | 1449.0 | 8.4 | False | None | None | False | None | False | 12171.6 | 0 | 3882224 | 149093 | None | code20 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required:
14.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rest | No | 4884.0 | 4884.0 | 4.0 | False | None | None | False | None | False | 19536.0 | 0 | 3882225 | 149093 | None | code21 | Providing and fxing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fttings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | No | 3082.0 | 3082.0 | 1.0 | False | None | None | False | None | False | 3082.0 | 0 | 3882226 | 149093 | None | code22 | Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 1000 litre capacity) | Ltr | 9.0 | 9.0 | 500.0 | False | None | None | False | None | False | 4500.0 | 0 | 3882227 | 149093 | None | code23 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore | No | 326.0 | 326.0 | 5.0 | False | None | None | False | None | False | 1630.0 | 0 | 3882228 | 149093 | None | code24 | Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this including the pipe with clamp at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete .(internal work exposed on wall) 25mm nominal OD Pipe | Mtr | 477.0 | 477.0 | 10.0 | False | None | None | False | None | False | 4770.0 | 0 |
|
|
---|