createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723545627753
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1500.00
emd102000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose05-09-2024 17:00:00
tenderQueryClose28-08-2024 17:00:00
technicalBidOpen07-09-2024 10:30:00
publishedDate13-08-2024 17:57:45
publishedByPostDUDC_EE1_BGV
publishedByUserKPE12048 - VITTAL S TADASALUR
bidValidityPeriod180
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonV S TADASLUR EE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber9480037328
mobileNumber9480037328
tenderSupplierListNone
tenderSchedule
createdTs1723545627800
version6
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT21170
titleConstruction of Toilet and drilling of Borewell and Construction Jalakhumba and supply and installation of High Mask Light at TMC MUGALKHOD of Belagavi District
descriptionConstruction of Toilet and drilling of Borewell and Construction Jalakhumba and supply and installation of High Mask Light at TMC MUGALKHOD of Belagavi District
categoryWORKS
categoryTextWorks
ecv6000000.02
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2213
locationNameDMA District Urban Development Cell Belagavi
provisionalAmount6000000.0
groupOverheadTotal925250.26
fileNumberDUDC/BGM/5CR/2024-25/100
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17235456280000NoneNoneOther WorksConstruction of Toilet1452714.27
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3768799141924Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete In all kinds of soils Depth upto 3 mCum107.1107.143.2FalseNoneNoneFalseNoneFalse4626.720
3768800141924Nonecode02Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.22.863FalseNoneNoneFalseNoneFalse17026.83360
3768801141924Nonecode03Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.457.584FalseNoneNoneFalseNoneFalse50876.88480
3768802141924Nonecode04Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.3518.17FalseNoneNoneFalseNoneFalse119946.52950
3768803141924Nonecode05Providing Thermo-Mechanically Treated bars of grade Fe-500 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)(Comman SR-21-22)VOL-2,I no-11.32 PAGE NO-84Tonne93929.8593929.853.816FalseNoneNoneFalseNoneFalse358436.30760
3768804141924Nonecode06Form Work: As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate - For Walls 10%Percentage660.13660.1312.599FalseNoneNoneFalseNoneFalse8316.977870
3768805141924Nonecode07Form Work: As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate For Beams & Lintels of Buildings Form Works Consider 50%Percentage3300.673300.672.0FalseNoneNoneFalseNoneFalse6601.340
3768806141924Nonecode08Form Work: As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate For Roof Slab of Buildings Form Works Consider 50%Percentage3300.673300.676.132FalseNoneNoneFalseNoneFalse20239.708440
3768807141924Nonecode09Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.317.4414FalseNoneNoneFalseNoneFalse4871.383020
3768808141924Nonecode10Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement: 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum9317.79317.726.2FalseNoneNoneFalseNoneFalse244123.740
3768809141924Nonecode11Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm389.55389.55275.57FalseNoneNoneFalseNoneFalse107348.29350
3768810141924Nonecode12Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Kg192.15192.1548.59FalseNoneNoneFalseNoneFalse9336.56850
3768811141924Nonecode13Providing Mathi/Nandi wood frames of doors, windows, clerestorywindows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum130412.1130412.10.22FalseNoneNoneFalseNoneFalse28690.6620
3768812141924Nonecode14Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. one side prelamSqm2142.02142.08.1FalseNoneNoneFalseNoneFalse17350.20
3768813141924Nonecode15Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separatelyLtr9.459.456000.0FalseNoneNoneFalseNoneFalse56700.00
3768814141924Nonecode16Supply, Errection commissioning of ………... Dia 4 Kgf/cm2 PVC Pipe For Night Soil and Urinal Connections to Septic Tank including all Accessories.Mtr182.7182.7225.0FalseNoneNoneFalseNoneFalse41107.50
3768815141924Nonecode17Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For PVC pipes 25mm dia, 10 kg/sqcm & class 5Mtr50.450.4750.0FalseNoneNoneFalseNoneFalse37800.00
3768816141924Nonecode18Providing and fixing PTMT bib cock of approved quality and colour.20 mm nominal bore, 89 mm long, weighing not less than 88 gNo151.2151.29.0FalseNoneNoneFalseNoneFalse1360.80
3768817141924Nonecode19Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 32 mm nominal boreNo627.9627.918.0FalseNoneNoneFalseNoneFalse11302.20
3768818141924Nonecode20Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Long pattern W.C Pan of size 580x440 mmEach2930.552930.559.0FalseNoneNoneFalseNoneFalse26374.950
3768819141924Nonecode21Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints Size of Tile 600x600 mmSqm1299.91299.929.28FalseNoneNoneFalseNoneFalse38061.0720
3768820141924Nonecode22Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete.Sqm1161.31161.3117.93FalseNoneNoneFalseNoneFalse136952.1090
3768821141924Nonecode23Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :One coat with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in charge.Sqm207.9207.9275.5755FalseNoneNoneFalseNoneFalse57292.146450
3768822141924Nonecode24Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:2010.Mtr75.675.660.0FalseNoneNoneFalseNoneFalse4536.00
3768823141924Nonecode25Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.Each159.6159.66.0FalseNoneNoneFalseNoneFalse957.60
3768824141924Nonecode26Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box.Each784.35784.353.0FalseNoneNoneFalseNoneFalse2353.050
3768825141924Nonecode27Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.Nos131.25131.2512.0FalseNoneNoneFalseNoneFalse1575.00
3768826141924Nonecode28Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.Each549.15549.156.0FalseNoneNoneFalseNoneFalse3294.90
3768827141924Nonecode29Point wiring using copper wire with switch.: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Two outlet in a row, above 3m upto 6m from tapping point to out let via switches.Point704.55704.5542.0FalseNoneNoneFalseNoneFalse29591.10
3768828141924Nonecode30Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments.4 mm2Mtr61.9561.9536.0FalseNoneNoneFalseNoneFalse2230.20
3768829141924Nonecode31Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. a) 6 Amps SP SwitchNos45.1545.156.0FalseNoneNoneFalseNoneFalse270.90
3768830141924Nonecode32b) 6 Amps 3 Way 5 Pin SocketNos68.2568.256.0FalseNoneNoneFalseNoneFalse409.50
3768831141924Nonecode33c) 6 Amps Bakelite Ceiling RoseNos66.1566.156.0FalseNoneNoneFalseNoneFalse396.90
3768832141924Nonecode34d) 6 Amps Lamps HolderNos66.1566.156.0FalseNoneNoneFalseNoneFalse396.90
3768833141924Nonecode35Supplying & fixing of Surface mounting type retrofit type LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 1)18W-20W (T8).Nos653.1653.13.0FalseNoneNoneFalseNoneFalse1959.30
17235456280000NoneNoneOther WorksDrilling of Borewell551908.2
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3768834141925Nonecode01Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner orSchlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. PWD SR 2023-24 VOLUME NO V I No 12.4 P no - 140Each5552.45552.43.0FalseNoneNoneFalseNoneFalse16657.20
3768835141925Nonecode02Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )Borewell depth of 0 to 50 m PWD SR 2023-24 VOL- V I no -12.1.1 P no-139Mtr388.5388.5150.0FalseNoneNoneFalseNoneFalse58275.00
3768836141925Nonecode03Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )Borewell depth of 50 to 100 m PWD SR 2023-24 VOL- V I no -12.1.2 P no-139 Borewell 50-100Mtr487.2487.2150.0FalseNoneNoneFalseNoneFalse73080.00
3768837141925Nonecode04Sinking of Borewell of 165 mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )Borewell depth of 100 to 150 m PWD SR 2023-24 VOL- V I no -12.1.3 P no-139 Bore well 100-150Mtr517.65517.6515.0FalseNoneNoneFalseNoneFalse7764.750
3768838141925Nonecode05Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. PWD SR 2023-24 P N- 143 I NO- 12.32Mtr2029.652029.6518.0FalseNoneNoneFalseNoneFalse36533.70
3768839141925Nonecode06Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments. PWD SR 2023-24 P NO -143 I NO- 12.33Each157.5157.53.0FalseNoneNoneFalseNoneFalse472.50
3768840141925Nonecode07Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge PWD SR 2023-24 P NO -143 I NO- 12.34Each172.2172.23.0FalseNoneNoneFalseNoneFalse516.60
3768841141925Nonecode08Providing, supplying to work site,Single Phase Submersible Pump Set sof 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments.(3.00 HP/2.2KW 9 STG) PWD SR 2023 -24 VOL-V P NO- 150 I NO- 13.9.1Each21118.6521118.653.0FalseNoneNoneFalseNoneFalse63355.950
3768842141925Nonecode09Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments PWD SR 2023-24 VOL-V P NO- 155 I NO- 13.28Mtr577.5577.5285.0FalseNoneNoneFalseNoneFalse164587.50
3768843141925Nonecode10Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core 1x3x2.5 m2 (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. PWD SR 2023-24 VOL-V P NO- 154 I NO- 13.22.2Mtr89.2589.25300.0FalseNoneNoneFalseNoneFalse26775.00
3768844141925Nonecode11Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter Upto 6 HP pumps PWD SR 2023-24 VOL- V I NO-13.23.2 P NO- 155( 3 to 6 HP pumps)Each10027.510027.53.0FalseNoneNoneFalseNoneFalse30082.50
3768845141925Nonecode12Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments 50mm dia PWD SR 2023-24 VOL-V P NO- 154 I NO- 13.24.1Each1312.51312.53.0FalseNoneNoneFalseNoneFalse3937.50
3768846141925Nonecode13Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments PWD SR 2023-24 VOL-V P NO- 154 I NO- 13.25.1Each1312.51312.53.0FalseNoneNoneFalseNoneFalse3937.50
3768847141925Nonecode14Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. PWD SR 2023-24 VOL-V P NO- 155 I NO- 13.25Kvar557.5557.53.0FalseNoneNoneFalseNoneFalse1672.50
3768848141925Nonecode15Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. PWD SR 2023-24 VOL-V P NO- 155 I NO- 13.26Per 3 Poles1207.51207.53.0FalseNoneNoneFalseNoneFalse3622.50
3768849141925Nonecode16Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) 50mm dia PWD SR 2023-24 VOL-V P NO- 155 I NO- 13.27Each3202.53202.53.0FalseNoneNoneFalseNoneFalse9607.50
3768850141925Nonecode17Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work .PWD SR 2023-24 VOL-V P NO- 156 I NO- 13.32Job6825.06825.03.0FalseNoneNoneFalseNoneFalse20475.00
3768851141925Nonecode18Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work.PWD SR 2023-24 VOL-V P NO- 156 I NO- 13.34Job1522.51522.53.0FalseNoneNoneFalseNoneFalse4567.50
3768852141925Nonecode19Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI mark. PWD SR 2023-24 VOL-V P NO- 156 I NO- 13.30Set4725.04725.03.0FalseNoneNoneFalseNoneFalse14175.00
3768853141925Nonecode20Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. PWD SR 2023-24 VOL-V P NO- 157 I NO- 13.39Job3937.53937.53.0FalseNoneNoneFalseNoneFalse11812.50
17235456280001NoneNoneOther WorksConstruction Jalakhumba860930.41
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3768854141926Nonecode01Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removalof stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In (all kinds of soils Depth upto 1.5) PWD COMMON SR 2023-24 VOLUM NO 1 ITEM NO 1.4 (1.4.1) PAGE NO 5Cum254.1254.117.09FalseNoneNoneFalseNoneFalse4342.5690
3768855141926Nonecode02Providing and laying in position Cement Concrete for levelling course forall works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (PWD Common DSR 2023-24 Volume 1 Page no 15 item no 2.1-2.1.2 Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.25.7FalseNoneNoneFalseNoneFalse33899.040
3768856141926Nonecode03Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD Common DSR 2023-24 P No.9/I No.5.1.1 Vol-2)Cum5891.555891.5551.3FalseNoneNoneFalseNoneFalse302236.5150
3768857141926Nonecode04RCC hume pipe Circular pump house: Supplying precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm PWD WS and UGD DSR 2023-24 Volume V (P No: 116 I.No: 10.6, ).Each17221.0517221.0519.0FalseNoneNoneFalseNoneFalse327199.950
3768858141926Nonecode05Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work. PWD WS and UGD DSR 2023-24Volume V (P No: 116 I.No:10.7, ).Each1976.11976.119.0FalseNoneNoneFalseNoneFalse37545.90
3768859141926Nonecode06Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. PWD SR 2023-24 Vol 1 P No 15 I No 2.1.3Cum6288.456288.458.265FalseNoneNoneFalseNoneFalse51974.039250
3768860141926Nonecode07Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. [PWD Common DSR 2023-24 Volume 2 (P No: 44 I.No:8.19.1)]Sqm167.75167.7584.36FalseNoneNoneFalseNoneFalse14151.390
3768861141926Nonecode08Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge 40 mm nominal dia Pipes (8.30)[ PWD SR Page No 46 item No 8.30 volum-2]Sqm182.7182.7112.86FalseNoneNoneFalseNoneFalse20619.5220
3768862141926Nonecode09Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall [PWD WS and CRS & BWSSB 2023-24 Volume II (P No: 122 I.No: 13.31.5 ) 40 mm nominal dia PipesMtr562.8562.819.0FalseNoneNoneFalseNoneFalse10693.20
3768863141926Nonecode10Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall [PWD WS and CRS & BWSSB 2023-24 Volume II (P No: 122 I.No: 13.31.2 )20 mm nominal dia PipesMtr254.1254.119.0FalseNoneNoneFalseNoneFalse4827.90
3768864141926Nonecode11Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Collor 20 mm dia. [2023-24 As Per Market Rate]Nos23.123.138.0FalseNoneNoneFalseNoneFalse877.80
3768865141926Nonecode12Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Tee 20 mm dia. [2023-24 As Per Market Rate]Nos46.246.238.0FalseNoneNoneFalseNoneFalse1755.60
3768866141926Nonecode13Providing and fixing Chlorinated Polyvinyl Chloride (PVC) Tap 20 mm dia. [2023-24 As Per Market Rate]Each26.2526.2519.0FalseNoneNoneFalseNoneFalse498.750
3768867141926Nonecode14Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removalof stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In (all kinds of soils Depth upto 1.5) PWD COMMON SR 2023-24 VOLUM NO 1 ITEM NO 1.4 -(1.4.1) PAGE NO 5Cum254.1254.130.78FalseNoneNoneFalseNoneFalse7821.1980
3768868141926Nonecode15Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 4 Kg/m2 : 63mm (WS & UCD, CSR 2023-24, VOL-5, P No-120, NO-10.14.1 SORRmtr122.85122.85209.0FalseNoneNoneFalseNoneFalse25675.650
3768869141926Nonecode16Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications, (CSR 2023-24 ,VOL-1 P NO-07, I NO 1.10)Cum168.0168.030.78FalseNoneNoneFalseNoneFalse5171.040
3768870141926Nonecode17Providing of Gunmetal Ball Valve of Non rising stem, screwed in bonnet, inside screw, integral seats, screwed female ends to IS:554/ BS 21/ ISO 7, Unbreakable sheet metal Handwheel, confoming to IS:778 Class-1 including provision of re-packing under pressure with appurtenances, complete : 150 mm nominal bore etc. complete PWD SR 2023-24 VOL -5 P NO- 35 I NO-2.60Each221.55221.5519.0FalseNoneNoneFalseNoneFalse4209.450
3768871141926Nonecode18Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 90 mm dia PVC Tee PWD SR 2023-24 VOL -5 P NO- 117 I NO-10.10.7Each179.55179.5519.0FalseNoneNoneFalseNoneFalse3411.450
3768872141926Nonecode19Supply and delivery at site special moulded variety PVC service saddles as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments mm dia PVC SERVICE SADDLESPWD SR 2023-24 VOL -5 P NO- 119 I NO-10.12.7 90Each211.55211.5519.0FalseNoneNoneFalseNoneFalse4019.450
17235456280000NoneNoneOther WorksConstruction Paver Work174937.97
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3768873141927Nonecode01Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum497.7497.719.5FalseNoneNoneFalseNoneFalse9705.150
3768874141927Nonecode02Providing and laying 80 mm thick factory made precast M-30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS15658 for Commercial Traffic Axle load repetitions upto 10 MSA & for Residential Streets of approved shape and colour,laid in required pattern and including over 40 mm thick compacted bedof coarse sand, filling the joints with fine sand etc.all complete asper the direction of Engineer-in-charge. (WMM/WBM Base to bepaid separately as per relevant technical specification)Sqm1219.051219.05130.0FalseNoneNoneFalseNoneFalse158476.50
3768875141927Nonecode03Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usagecharges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.851.035FalseNoneNoneFalseNoneFalse6756.324750
17235456280001NoneNoneOther WorksSupply and Installation of High Mask Light2034258.91
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3768876141928Nonecode01Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completelyMtr19.9519.9510.0FalseNoneNoneFalseNoneFalse199.50
3768877141928Nonecode02Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 1.5 mm2 694:2010Mtr27.327.320.0FalseNoneNoneFalseNoneFalse546.00
3768878141928Nonecode032.5 mm2Mtr44.144.130.0FalseNoneNoneFalseNoneFalse1323.00
3768879141928Nonecode044 mm2Mtr66.1566.1525.0FalseNoneNoneFalseNoneFalse1653.750
3768880141928Nonecode056 mm2Mtr96.696.630.0FalseNoneNoneFalseNoneFalse2898.00
3768881141928Nonecode06Fabrication, Supplying, Erection, Testing and Commissioning of ms long Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot- dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data.Each122850.0122850.01.0FalseNoneNoneFalseNoneFalse122850.00
3768882141928Nonecode07Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990Mtr118.65118.65140.0FalseNoneNoneFalseNoneFalse16611.00
3768883141928Nonecode08Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.Each23171.423171.48.0FalseNoneNoneFalseNoneFalse185371.20
3768884141928Nonecode09Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wiresEach170.1170.18.0FalseNoneNoneFalseNoneFalse1360.80
3768885141928Nonecode10Supplying &fixingof Porcelai fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.PAGE NO-10 ,I -NO-.5.7 SR 202-22,PART - 1Each421.05421.056.0FalseNoneNoneFalseNoneFalse2526.30
3768886141928Nonecode11Supplyand fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nut boult washers and wiring etc. complete with AC-3 Rating and as per IS-13947. Part - I chapter -5,Page No -11Each2370.92370.91.0FalseNoneNoneFalseNoneFalse2370.90
3768887141928Nonecode12Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C'Type curve indicator ON/OFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingEach435.75435.753.0FalseNoneNoneFalseNoneFalse1307.250
3768888141928Nonecode1340 A TPNEach3196.23196.22.0FalseNoneNoneFalseNoneFalse6392.40
3768889141928Nonecode14Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach210.0210.02.0FalseNoneNoneFalseNoneFalse420.00
3768890141928Nonecode15Supplying ....A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board The busbar shall suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc.completeMtr2588.252588.250.4FalseNoneNoneFalseNoneFalse1035.30
3768891141928Nonecode16Supplying and fixing angle iron frame work fabricated out of MS.angle iron. and M.S Flat.....with bolts, washers etc.and painted with 2 coats of red oxide and then two coats of approved paint.Mtr414.75414.7512.0FalseNoneNoneFalseNoneFalse4977.00
3768892141928Nonecode17Fabricating supplying and mounting MS box made out....SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc.,Sqm0.520.5222600.0FalseNoneNoneFalseNoneFalse11752.00
3768893141928Nonecode18Supplying and fixing Microprocessor based Electronit timer (without contactor Din Mounting using necessary bolts, nuts and washers etc.) 3-120sec setting.Page No-16,Part -IEach2430.752430.751.0FalseNoneNoneFalseNoneFalse2430.750
3768894141928Nonecode19Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws.Sqm0.360.3618000.0FalseNoneNoneFalseNoneFalse6480.00
3768895141928Nonecode20Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. CIVIL SR 2022-23 OF V-I PAGE NO-8, I-1.13Cum352.8352.815.625FalseNoneNoneFalseNoneFalse5512.50
3768896141928Nonecode21Providing and laying in position plain cement concrete for levelling course for all works in foundation.The ranite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as petechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) CIVIL SR 2022-23 OF V-I PAGE NO-15, I-2.1,2.1.2Cum5913.815913.810.78FalseNoneNoneFalseNoneFalse4612.77180
3768897141928Nonecode22Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) ) CIVIL SR 2022-23 OF V-I PAGE NO-13, I-2.1,2..21.1Cum6869.676869.673.31FalseNoneNoneFalseNoneFalse22738.60770
3768898141928Nonecode23Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation/Substructure/Super structure complete as per Drawing and Technical Specifications.CIVIL SR 2022-23 OF V-III, PAGE NO-108 CHAPTER - 9,,l.No-9.3Tonne84204.5484204.540.099FalseNoneNoneFalseNoneFalse8336.249460
3768899141928Nonecode24Supplying and fixing hylum plastic sheet 3mm Thick with necessary nitches for fixing switches,regulators etc., and fixing on existing wood or metal box using N. F.Screws Part - I chapter -2,Page No -6.Sqm0.270.276800.0FalseNoneNoneFalseNoneFalse1836.00
3768900141928Nonecode251.1 kV,XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1,Armouring strip thickness and resistivity as per IS-3975 PART III,..PAGE NO -9Km148934.1148934.10.38FalseNoneNoneFalseNoneFalse56594.9580
3768901141928Nonecode26Laying of cable in Existing Trench/GI pipe/ Stone Ware /RCC Hume pipe using Wooden /Aluminum Rollers as directed by the departmental staff PART -IV, PAGE NO - 9Mtr16966.9516966.950.3FalseNoneNoneFalseNoneFalse5090.0850
3768902141928Nonecode27Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.PART -IV ,..PAGE NO - 8Sqm408.45408.4522.5FalseNoneNoneFalseNoneFalse9190.1250
3768903141928Nonecode28Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr PART- IV , PAGE NO-8Sqm60.960.925.0FalseNoneNoneFalseNoneFalse1522.50
3768904141928Nonecode29Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.PART NO-IV, PAGR -8Mtr60.960.98.0FalseNoneNoneFalseNoneFalse487.20
3768905141928Nonecode30GI Pipe - 50 mm Dia PART -III, PAGE NO - 16Mtr402.15402.158.0FalseNoneNoneFalseNoneFalse3217.20
3768906141928Nonecode31HDPE/PLB Pipe 50/42 mm PART-III PAGE-26Km87051.387051.30.1FalseNoneNoneFalseNoneFalse8705.130
3768907141928Nonecode32GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg PART-III, PAGE NO-17No808.5808.53.0FalseNoneNoneFalseNoneFalse2425.50
3768908141928Nonecode33Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each PART-III PAGE NO-17No693.0693.02.0FalseNoneNoneFalseNoneFalse1386.00
3768909141928Nonecode34Good Quality Salt for grounding purposes packed in 50 Kg gunny bag PART-III PAGE NO-17Bag318.15318.152.0FalseNoneNoneFalseNoneFalse636.30
3768910141928Nonecode3510 SqmmNo3.153.1536.0FalseNoneNoneFalseNoneFalse113.40
3768911141928Nonecode3616 SqmmNo3.153.1512.0FalseNoneNoneFalseNoneFalse37.80
3768912141928Nonecode37Digging of Pit for providing GI Pipe type Earthing LABOUR RATE PART -IV PAGE NO - 1Pit606.9606.93.0FalseNoneNoneFalseNoneFalse1820.70
3768913141928Nonecode388 SWG GI Wire MT - PER KG (4.064 mm Dia), Std Wt: 125 Kg/KM PART - III , ..PAGE NO - 3Pit81742.581742.50.02FalseNoneNoneFalseNoneFalse1634.850
3768914141928Nonecode39Brass Cable Gland PART -III ,..PAGE NO -25No80.8580.852.0FalseNoneNoneFalseNoneFalse161.70
3768915141928Nonecode40Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completelyMtr19.9519.9510.0FalseNoneNoneFalseNoneFalse199.50
3768916141928Nonecode41Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 1.5 mm2 694:2010Mtr27.327.320.0FalseNoneNoneFalseNoneFalse546.00
3768917141928Nonecode422.5 mm2Mtr44.144.130.0FalseNoneNoneFalseNoneFalse1323.00
3768918141928Nonecode434 mm2Mtr66.1566.1525.0FalseNoneNoneFalseNoneFalse1653.750
3768919141928Nonecode446 mm2Mtr96.696.630.0FalseNoneNoneFalseNoneFalse2898.00
3768920141928Nonecode45Fabrication, Supplying, Erection, Testing and Commissioning of ms long Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot- dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data.Each122850.0122850.01.0FalseNoneNoneFalseNoneFalse122850.00
3768921141928Nonecode46Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990Mtr118.65118.65140.0FalseNoneNoneFalseNoneFalse16611.00
3768922141928Nonecode47Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.Each23171.423171.48.0FalseNoneNoneFalseNoneFalse185371.20
3768923141928Nonecode48Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wiresEach170.1170.18.0FalseNoneNoneFalseNoneFalse1360.80
3768924141928Nonecode49Supplying &fixingof Porcelai fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.PAGE NO-10 ,I -NO-.5.7 SR 202-22,PART - 1Each421.05421.056.0FalseNoneNoneFalseNoneFalse2526.30
3768925141928Nonecode50Supplyand fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nut boult washers and wiring etc. complete with AC-3 Rating and as per IS-13947. Part - I chapter -5,Page No -11Each2370.92370.91.0FalseNoneNoneFalseNoneFalse2370.90
3768926141928Nonecode51Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C'Type curve indicator ON/OFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingEach435.75435.753.0FalseNoneNoneFalseNoneFalse1307.250
3768927141928Nonecode5240 A TPNEach3196.23196.22.0FalseNoneNoneFalseNoneFalse6392.40
3768928141928Nonecode53Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach210.0210.02.0FalseNoneNoneFalseNoneFalse420.00
3768929141928Nonecode54Supplying ....A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board The busbar shall suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc.completeMtr2588.252588.250.4FalseNoneNoneFalseNoneFalse1035.30
3768930141928Nonecode55Supplying and fixing angle iron frame work fabricated out of MS.angle iron. and M.S Flat.....with bolts, washers etc.and painted with 2 coats of red oxide and then two coats of approved paint.Mtr414.75414.7512.0FalseNoneNoneFalseNoneFalse4977.00
3768931141928Nonecode56Fabricating supplying and mounting MS box made out....SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc.,Sqm0.520.5222600.0FalseNoneNoneFalseNoneFalse11752.00
3768932141928Nonecode57Supplying and fixing Microprocessor based Electronit timer (without contactor Din Mounting using necessary bolts, nuts and washers etc.) 3-120sec setting.Page No-16,Part -IEach2430.752430.751.0FalseNoneNoneFalseNoneFalse2430.750
3768933141928Nonecode58Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws.Sqm0.360.3618000.0FalseNoneNoneFalseNoneFalse6480.00
3768934141928Nonecode59Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. CIVIL SR 2022-23 OF V-I PAGE NO-8, I-1.13Cum352.8352.815.625FalseNoneNoneFalseNoneFalse5512.50
3768935141928Nonecode60Providing and laying in position plain cement concrete for levelling course for all works in foundation.The ranite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as petechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) CIVIL SR 2022-23 OF V-I PAGE NO-15, I-2.1,2.1.2Cum5913.815913.810.78FalseNoneNoneFalseNoneFalse4612.77180
3768936141928Nonecode61Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) ) CIVIL SR 2022-23 OF V-I PAGE NO-13, I-2.1,2..21.1Cum6869.676869.673.31FalseNoneNoneFalseNoneFalse22738.60770
3768937141928Nonecode62Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation/Substructure/Super structure complete as per Drawing and Technical Specifications.CIVIL SR 2022-23 OF V-III, PAGE NO-108 CHAPTER - 9,,l.No-9.3Tonne84204.5484204.540.099FalseNoneNoneFalseNoneFalse8336.249460
3768938141928Nonecode63Supplying and fixing hylum plastic sheet 3mm Thick with necessary nitches for fixing switches,regulators etc., and fixing on existing wood or metal box using N. F.Screws Part - I chapter -2,Page No -6.Sqm0.270.276800.0FalseNoneNoneFalseNoneFalse1836.00
3768939141928Nonecode641.1 kV,XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1,Armouring strip thickness and resistivity as per IS-3975 PART III,..PAGE NO -9Km148934.1148934.10.38FalseNoneNoneFalseNoneFalse56594.9580
3768940141928Nonecode65Laying of cable in Existing Trench/GI pipe/ Stone Ware /RCC Hume pipe using Wooden /Aluminum Rollers as directed by the departmental staff PART -IV, PAGE NO - 9Mtr16966.9516966.950.3FalseNoneNoneFalseNoneFalse5090.0850
3768941141928Nonecode66Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.PART -IV ,..PAGE NO - 8Sqm408.45408.4522.5FalseNoneNoneFalseNoneFalse9190.1250
3768942141928Nonecode67Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr PART- IV , PAGE NO-8Sqm60.960.925.0FalseNoneNoneFalseNoneFalse1522.50
3768943141928Nonecode68Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.PART NO-IV, PAGR -8Mtr60.960.98.0FalseNoneNoneFalseNoneFalse487.20
3768944141928Nonecode69GI Pipe - 50 mm Dia PART -III, PAGE NO - 16Mtr402.15402.158.0FalseNoneNoneFalseNoneFalse3217.20
3768945141928Nonecode70HDPE/PLB Pipe 50/42 mm PART-III PAGE-26Km87051.387051.30.1FalseNoneNoneFalseNoneFalse8705.130
3768946141928Nonecode71GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg PART-III, PAGE NO-17No808.5808.53.0FalseNoneNoneFalseNoneFalse2425.50
3768947141928Nonecode72Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each PART-III PAGE NO-17No693.0693.02.0FalseNoneNoneFalseNoneFalse1386.00
3768948141928Nonecode73Good Quality Salt for grounding purposes packed in 50 Kg gunny bag PART-III PAGE NO-17Bag318.15318.152.0FalseNoneNoneFalseNoneFalse636.30
3768949141928Nonecode7410 SqmmNo3.153.1536.0FalseNoneNoneFalseNoneFalse113.40
3768950141928Nonecode7516 SqmmNo3.153.1512.0FalseNoneNoneFalseNoneFalse37.80
3768951141928Nonecode76Digging of Pit for providing GI Pipe type Earthing LABOUR RATE PART -IV PAGE NO - 1Pit606.9606.93.0FalseNoneNoneFalseNoneFalse1820.70
3768952141928Nonecode778 SWG GI Wire MT - PER KG (4.064 mm Dia), Std Wt: 125 Kg/KM PART - III , ..PAGE NO - 3Pit81742.581742.50.02FalseNoneNoneFalseNoneFalse1634.850
3768953141928Nonecode78Brass Cable Gland PART -III ,..PAGE NO -25No80.8580.852.0FalseNoneNoneFalseNoneFalse161.70
3768954141928Nonecode79Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completelyMtr19.9519.9510.0FalseNoneNoneFalseNoneFalse199.50
3768955141928Nonecode80Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 1.5 mm2 694:2010Mtr27.327.320.0FalseNoneNoneFalseNoneFalse546.00
3768956141928Nonecode812.5 mm2Mtr44.144.130.0FalseNoneNoneFalseNoneFalse1323.00
3768957141928Nonecode824 mm2Mtr66.1566.1525.0FalseNoneNoneFalseNoneFalse1653.750
3768958141928Nonecode836 mm2Mtr96.696.630.0FalseNoneNoneFalseNoneFalse2898.00
3768959141928Nonecode84Fabrication, Supplying, Erection, Testing and Commissioning of ms long Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot- dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data.Each122850.0122850.01.0FalseNoneNoneFalseNoneFalse122850.00
3768960141928Nonecode85Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990Mtr118.65118.65140.0FalseNoneNoneFalseNoneFalse16611.00
3768961141928Nonecode86Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.Each23171.423171.48.0FalseNoneNoneFalseNoneFalse185371.20
3768962141928Nonecode87Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wiresEach170.1170.18.0FalseNoneNoneFalseNoneFalse1360.80
3768963141928Nonecode88Supplying &fixingof Porcelai fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.PAGE NO-10 ,I -NO-.5.7 SR 202-22,PART - 1Each421.05421.056.0FalseNoneNoneFalseNoneFalse2526.30
3768964141928Nonecode89Supplyand fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nut boult washers and wiring etc. complete with AC-3 Rating and as per IS-13947. Part - I chapter -5,Page No -11Each2370.92370.91.0FalseNoneNoneFalseNoneFalse2370.90
3768965141928Nonecode90Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C'Type curve indicator ON/OFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingEach435.75435.753.0FalseNoneNoneFalseNoneFalse1307.250
3768966141928Nonecode9140 A TPNEach3196.23196.22.0FalseNoneNoneFalseNoneFalse6392.40
3768967141928Nonecode92Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach210.0210.02.0FalseNoneNoneFalseNoneFalse420.00
3768968141928Nonecode93Supplying ....A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board The busbar shall suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc.completeMtr2588.252588.250.4FalseNoneNoneFalseNoneFalse1035.30
3768969141928Nonecode94Supplying and fixing angle iron frame work fabricated out of MS.angle iron. and M.S Flat.....with bolts, washers etc.and painted with 2 coats of red oxide and then two coats of approved paint.Mtr414.75414.7512.0FalseNoneNoneFalseNoneFalse4977.00
3768970141928Nonecode95Fabricating supplying and mounting MS box made out....SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc.,Sqm0.520.5222600.0FalseNoneNoneFalseNoneFalse11752.00
3768971141928Nonecode96Supplying and fixing Microprocessor based Electronit timer (without contactor Din Mounting using necessary bolts, nuts and washers etc.) 3-120sec setting.Page No-16,Part -IEach2430.752430.751.0FalseNoneNoneFalseNoneFalse2430.750
3768972141928Nonecode97Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws.Sqm0.360.3618000.0FalseNoneNoneFalseNoneFalse6480.00
3768973141928Nonecode98Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. CIVIL SR 2022-23 OF V-I PAGE NO-8, I-1.13Cum352.8352.815.625FalseNoneNoneFalseNoneFalse5512.50
3768974141928Nonecode99Providing and laying in position plain cement concrete for levelling course for all works in foundation.The ranite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as petechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) CIVIL SR 2022-23 OF V-I PAGE NO-15, I-2.1,2.1.2Cum5913.815913.810.78FalseNoneNoneFalseNoneFalse4612.77180
3768975141928Nonecode100Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) ) CIVIL SR 2022-23 OF V-I PAGE NO-13, I-2.1,2..21.1Cum6869.676869.673.31FalseNoneNoneFalseNoneFalse22738.60770
3768976141928Nonecode101Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation/Substructure/Super structure complete as per Drawing and Technical Specifications.CIVIL SR 2022-23 OF V-III, PAGE NO-108 CHAPTER - 9,,l.No-9.3Tonne84204.5484204.540.099FalseNoneNoneFalseNoneFalse8336.249460
3768977141928Nonecode102Supplying and fixing hylum plastic sheet 3mm Thick with necessary nitches for fixing switches,regulators etc., and fixing on existing wood or metal box using N. F.Screws Part - I chapter -2,Page No -6.Sqm0.270.276800.0FalseNoneNoneFalseNoneFalse1836.00
3768978141928Nonecode1031.1 kV,XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1,Armouring strip thickness and resistivity as per IS-3975 PART III,..PAGE NO -9Km148934.1148934.10.38FalseNoneNoneFalseNoneFalse56594.9580
3768979141928Nonecode104Laying of cable in Existing Trench/GI pipe/ Stone Ware /RCC Hume pipe using Wooden /Aluminum Rollers as directed by the departmental staff PART -IV, PAGE NO - 9Mtr16966.9516966.950.3FalseNoneNoneFalseNoneFalse5090.0850
3768980141928Nonecode105Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.PART -IV ,..PAGE NO - 8Sqm408.45408.4522.5FalseNoneNoneFalseNoneFalse9190.1250
3768981141928Nonecode106Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr PART- IV , PAGE NO-8Sqm60.960.925.0FalseNoneNoneFalseNoneFalse1522.50
3768982141928Nonecode107Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.PART NO-IV, PAGR -8Mtr60.960.98.0FalseNoneNoneFalseNoneFalse487.20
3768983141928Nonecode108GI Pipe - 50 mm Dia PART -III, PAGE NO - 16Mtr402.15402.158.0FalseNoneNoneFalseNoneFalse3217.20
3768984141928Nonecode109HDPE/PLB Pipe 50/42 mm PART-III PAGE-26Km87051.387051.30.1FalseNoneNoneFalseNoneFalse8705.130
3768985141928Nonecode110GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg PART-III, PAGE NO-17No808.5808.53.0FalseNoneNoneFalseNoneFalse2425.50
3768986141928Nonecode111Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each PART-III PAGE NO-17No693.0693.02.0FalseNoneNoneFalseNoneFalse1386.00
3768987141928Nonecode112Good Quality Salt for grounding purposes packed in 50 Kg gunny bag PART-III PAGE NO-17Bag318.15318.152.0FalseNoneNoneFalseNoneFalse636.30
3768988141928Nonecode11310 SqmmNo3.153.1536.0FalseNoneNoneFalseNoneFalse113.40
3768989141928Nonecode11416 SqmmNo3.153.1512.0FalseNoneNoneFalseNoneFalse37.80
3768990141928Nonecode115Digging of Pit for providing GI Pipe type Earthing LABOUR RATE PART -IV PAGE NO - 1Pit606.9606.93.0FalseNoneNoneFalseNoneFalse1820.70
3768991141928Nonecode1168 SWG GI Wire MT - PER KG (4.064 mm Dia), Std Wt: 125 Kg/KM PART - III , ..PAGE NO - 3Pit81742.581742.50.02FalseNoneNoneFalseNoneFalse1634.850
3768992141928Nonecode117Brass Cable Gland PART -III ,..PAGE NO -25No80.8580.852.0FalseNoneNoneFalseNoneFalse161.70
3768993141928Nonecode118Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completelyMtr19.9519.9510.0FalseNoneNoneFalseNoneFalse199.50
3768994141928Nonecode119Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 1.5 mm2 694:2010Mtr27.327.320.0FalseNoneNoneFalseNoneFalse546.00
3768995141928Nonecode1202.5 mm2Mtr44.144.130.0FalseNoneNoneFalseNoneFalse1323.00
3768996141928Nonecode1214 mm2Mtr66.1566.1525.0FalseNoneNoneFalseNoneFalse1653.750
3768997141928Nonecode1226 mm2Mtr96.696.630.0FalseNoneNoneFalseNoneFalse2898.00
3768998141928Nonecode123Fabrication, Supplying, Erection, Testing and Commissioning of ms long Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot- dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data.Each122850.0122850.01.0FalseNoneNoneFalseNoneFalse122850.00
3768999141928Nonecode124Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990Mtr118.65118.65140.0FalseNoneNoneFalseNoneFalse16611.00
3769000141928Nonecode125Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.Each23171.423171.48.0FalseNoneNoneFalseNoneFalse185371.20
3769001141928Nonecode126Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wiresEach170.1170.18.0FalseNoneNoneFalseNoneFalse1360.80
3769002141928Nonecode127Supplying &fixingof Porcelai fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.PAGE NO-10 ,I -NO-.5.7 SR 202-22,PART - 1Each421.05421.056.0FalseNoneNoneFalseNoneFalse2526.30
3769003141928Nonecode128Supplyand fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nut boult washers and wiring etc. complete with AC-3 Rating and as per IS-13947. Part - I chapter -5,Page No -11Each2370.92370.91.0FalseNoneNoneFalseNoneFalse2370.90
3769004141928Nonecode129Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C'Type curve indicator ON/OFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingEach435.75435.753.0FalseNoneNoneFalseNoneFalse1307.250
3769005141928Nonecode13040 A TPNEach3196.23196.22.0FalseNoneNoneFalseNoneFalse6392.40
3769006141928Nonecode131Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach210.0210.02.0FalseNoneNoneFalseNoneFalse420.00
3769007141928Nonecode132Supplying ....A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board The busbar shall suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc.completeMtr2588.252588.250.4FalseNoneNoneFalseNoneFalse1035.30
3769008141928Nonecode133Supplying and fixing angle iron frame work fabricated out of MS.angle iron. and M.S Flat.....with bolts, washers etc.and painted with 2 coats of red oxide and then two coats of approved paint.Mtr414.75414.7512.0FalseNoneNoneFalseNoneFalse4977.00
3769009141928Nonecode134Fabricating supplying and mounting MS box made out....SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc.,Sqm0.520.5222600.0FalseNoneNoneFalseNoneFalse11752.00
3769010141928Nonecode135Supplying and fixing Microprocessor based Electronit timer (without contactor Din Mounting using necessary bolts, nuts and washers etc.) 3-120sec setting.Page No-16,Part -IEach2430.752430.751.0FalseNoneNoneFalseNoneFalse2430.750
3769011141928Nonecode136Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws.Sqm0.360.3618000.0FalseNoneNoneFalseNoneFalse6480.00
3769012141928Nonecode137Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. CIVIL SR 2022-23 OF V-I PAGE NO-8, I-1.13Cum352.8352.815.625FalseNoneNoneFalseNoneFalse5512.50
3769013141928Nonecode138Providing and laying in position plain cement concrete for levelling course for all works in foundation.The ranite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as petechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) CIVIL SR 2022-23 OF V-I PAGE NO-15, I-2.1,2.1.2Cum5913.815913.810.78FalseNoneNoneFalseNoneFalse4612.77180
3769014141928Nonecode139Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) ) CIVIL SR 2022-23 OF V-I PAGE NO-13, I-2.1,2..21.1Cum6869.676869.673.31FalseNoneNoneFalseNoneFalse22738.60770
3769015141928Nonecode140Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation/Substructure/Super structure complete as per Drawing and Technical Specifications.CIVIL SR 2022-23 OF V-III, PAGE NO-108 CHAPTER - 9,,l.No-9.3Tonne84204.5484204.540.099FalseNoneNoneFalseNoneFalse8336.249460
3769016141928Nonecode141Supplying and fixing hylum plastic sheet 3mm Thick with necessary nitches for fixing switches,regulators etc., and fixing on existing wood or metal box using N. F.Screws Part - I chapter -2,Page No -6.Sqm0.270.276800.0FalseNoneNoneFalseNoneFalse1836.00
3769017141928Nonecode1421.1 kV,XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1,Armouring strip thickness and resistivity as per IS-3975 PART III,..PAGE NO -9Km148934.1148934.10.38FalseNoneNoneFalseNoneFalse56594.9580
3769018141928Nonecode143Laying of cable in Existing Trench/GI pipe/ Stone Ware /RCC Hume pipe using Wooden /Aluminum Rollers as directed by the departmental staff PART -IV, PAGE NO - 9Mtr16966.9516966.950.3FalseNoneNoneFalseNoneFalse5090.0850
3769019141928Nonecode144Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.PART -IV ,..PAGE NO - 8Sqm408.45408.4522.5FalseNoneNoneFalseNoneFalse9190.1250
3769020141928Nonecode145Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr PART- IV , PAGE NO-8Sqm60.960.925.0FalseNoneNoneFalseNoneFalse1522.50
3769021141928Nonecode146Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.PART NO-IV, PAGR -8Mtr60.960.98.0FalseNoneNoneFalseNoneFalse487.20
3769022141928Nonecode147GI Pipe - 50 mm Dia PART -III, PAGE NO - 16Mtr402.15402.158.0FalseNoneNoneFalseNoneFalse3217.20
3769023141928Nonecode148HDPE/PLB Pipe 50/42 mm PART-III PAGE-26Km87051.387051.30.1FalseNoneNoneFalseNoneFalse8705.130
3769024141928Nonecode149GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg PART-III, PAGE NO-17No808.5808.53.0FalseNoneNoneFalseNoneFalse2425.50
3769025141928Nonecode150Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each PART-III PAGE NO-17No693.0693.02.0FalseNoneNoneFalseNoneFalse1386.00
3769026141928Nonecode151Good Quality Salt for grounding purposes packed in 50 Kg gunny bag PART-III PAGE NO-17Bag318.15318.152.0FalseNoneNoneFalseNoneFalse636.30
3769027141928Nonecode15210 SqmmNo3.153.1536.0FalseNoneNoneFalseNoneFalse113.40
3769028141928Nonecode15316 SqmmNo3.153.1512.0FalseNoneNoneFalseNoneFalse37.80
3769029141928Nonecode154Digging of Pit for providing GI Pipe type Earthing LABOUR RATE PART -IV PAGE NO - 1Pit606.9606.93.0FalseNoneNoneFalseNoneFalse1820.70
3769030141928Nonecode1558 SWG GI Wire MT - PER KG (4.064 mm Dia), Std Wt: 125 Kg/KM PART - III , ..PAGE NO - 3Pit81742.581742.50.02FalseNoneNoneFalseNoneFalse1634.850
3769031141928Nonecode156Brass Cable Gland PART -III ,..PAGE NO -25No80.8580.852.0FalseNoneNoneFalseNoneFalse161.70
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17235456290000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17235456290000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17235456290000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17235456290000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17235456290000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSatisfactoriy completed as prime contractor at-least one such similar Building and Road work of value not less than Rs. 25.41 (50% of estimated cost of tender)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Earthwork Excavation / Embankment -173.06Cum,Cement concrete PCC/RCC -51.35Cum,Steel Reinforcement/ Fabrication Work/ Structural Steel-3.81Tonne,Interlock Pavers -972.00 Sqm,Stone Masanory / Brick Masonary-85.09Cum) (80% of peak rate of construction)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneContractor Registation CertificateCapabilities of VendorOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. 101.64 Lakhs)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs.15.24 Lakhs (estimated cash flow for 3 months of peak construction period)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneDeletedOthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others
NoneNoneNoneNoneDeletedOthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others
NoneNoneNoneNoneDeletedOthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others
NoneNoneNoneNoneList of existing commitments and ongoing worksOthersList of existing commitments and ongoing works
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of existing commitments and ongoing works
NoneNoneNoneNoneList of works for which tenders already submittedOthersList of works for which tenders already submitted
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of works for which tenders already submitted
NoneNoneNoneNoneDeletedOthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others
NoneNoneNoneNoneDeletedOthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others
NoneNoneNoneNoneDeletedOthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others
NoneNoneNoneNoneDeletedOthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others
NoneNoneNoneNoneDeletedOthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Contractor Registration CertificateTrueTechnical Bid
Annual Turnover CertificateTrueTechnical Bid
Similar Work Done CertificateTrueTechnical Bid
Min Quanties of Work DoneTrueTechnical Bid
Line of CreditTrueTechnical Bid
Tender bid CapacityTrueTechnical Bid
Any Other Documents as per tender DocumentFalseTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone