tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1723545628000 | 0 | None | None | Other Works | Construction of Toilet | 1452714.27 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3768799 | 141924 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 43.2 | False | None | None | False | None | False | 4626.72 | 0 | 3768800 | 141924 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.
Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 2.863 | False | None | None | False | None | False | 17026.8336 | 0 | 3768801 | 141924 | None | code03 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 7.584 | False | None | None | False | None | False | 50876.8848 | 0 | 3768802 | 141924 | None | code04 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 18.17 | False | None | None | False | None | False | 119946.5295 | 0 | 3768803 | 141924 | None | code05 | Providing Thermo-Mechanically Treated bars of grade Fe-500 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)(Comman SR-21-22)VOL-2,I no-11.32 PAGE NO-84 | Tonne | 93929.85 | 93929.85 | 3.816 | False | None | None | False | None | False | 358436.3076 | 0 | 3768804 | 141924 | None | code06 | Form Work: As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate - For Walls 10% | Percentage | 660.13 | 660.13 | 12.599 | False | None | None | False | None | False | 8316.97787 | 0 | 3768805 | 141924 | None | code07 | Form Work: As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate For Beams & Lintels of Buildings Form Works Consider 50% | Percentage | 3300.67 | 3300.67 | 2.0 | False | None | None | False | None | False | 6601.34 | 0 | 3768806 | 141924 | None | code08 | Form Work: As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate For Roof Slab of Buildings Form Works Consider 50% | Percentage | 3300.67 | 3300.67 | 6.132 | False | None | None | False | None | False | 20239.70844 | 0 | 3768807 | 141924 | None | code09 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 17.4414 | False | None | None | False | None | False | 4871.38302 | 0 | 3768808 | 141924 | None | code10 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement: 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 9317.7 | 9317.7 | 26.2 | False | None | None | False | None | False | 244123.74 | 0 | 3768809 | 141924 | None | code11 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 389.55 | 389.55 | 275.57 | False | None | None | False | None | False | 107348.2935 | 0 | 3768810 | 141924 | None | code12 | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 48.59 | False | None | None | False | None | False | 9336.5685 | 0 | 3768811 | 141924 | None | code13 | Providing Mathi/Nandi wood frames of doors, windows, clerestorywindows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 130412.1 | 130412.1 | 0.22 | False | None | None | False | None | False | 28690.662 | 0 | 3768812 | 141924 | None | code14 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. one side prelam | Sqm | 2142.0 | 2142.0 | 8.1 | False | None | None | False | None | False | 17350.2 | 0 | 3768813 | 141924 | None | code15 | Providing and fixing rectangular high density polyethylene water storage
loft tank with cover, conforming to ISI : 12701, colour of opaque white or
as approved by Engineer-in-charge. The rate includes making necessary
holes for inlet, outlet & over flow pipes. The base support i/c fittings &
fixtures for tank shall be paid separately | Ltr | 9.45 | 9.45 | 6000.0 | False | None | None | False | None | False | 56700.0 | 0 | 3768814 | 141924 | None | code16 | Supply, Errection commissioning of ………... Dia 4 Kgf/cm2 PVC Pipe For Night Soil and Urinal Connections to Septic Tank including all Accessories. | Mtr | 182.7 | 182.7 | 225.0 | False | None | None | False | None | False | 41107.5 | 0 | 3768815 | 141924 | None | code17 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations
and cuts of pipes wherever necessary including jointing of PVC pipes
and specials (excluding cost of specials) with jointing of approved
type, with all labour with all lead & lift including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will make
his own arrangements for procuring water for testing) etc. complete For PVC pipes 25mm dia, 10 kg/sqcm & class 5 | Mtr | 50.4 | 50.4 | 750.0 | False | None | None | False | None | False | 37800.0 | 0 | 3768816 | 141924 | None | code18 | Providing and fixing PTMT bib cock of approved quality and colour.20 mm nominal bore, 89 mm long, weighing not less than 88 g | No | 151.2 | 151.2 | 9.0 | False | None | None | False | None | False | 1360.8 | 0 | 3768817 | 141924 | None | code19 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 32 mm nominal bore | No | 627.9 | 627.9 | 18.0 | False | None | None | False | None | False | 11302.2 | 0 | 3768818 | 141924 | None | code20 | Providing & fixing White vitreous china water closet squatting pan (Indian
type) along with "S" or "P" trap including dismantling of old WC seat and
"S" or "P" trap at site complete with all operations including all necessary
materials, labour and disposal of dismantled material i/c malba, all
complete as per the direction of Engineer-in charge. Long pattern W.C Pan of size 580x440 mm | Each | 2930.55 | 2930.55 | 9.0 | False | None | None | False | None | False | 26374.95 | 0 | 3768819 | 141924 | None | code21 | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with
different sizes with water absorption less than 0.08% and conforming to
IS:15622, of approved brand & manufacturer, in all colours and shade, laid
with cement based high polymer modified quick set tile adhesive (water
based) conforming to IS : 15477, in average 6 mm thickness, including
grouting of joints Size of Tile 600x600 mm | Sqm | 1299.9 | 1299.9 | 29.28 | False | None | None | False | None | False | 38061.072 | 0 | 3768820 | 141924 | None | code22 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:
15622 (thickness to be specified by the manufacturer), of approved make,
in all colours, shades except burgundy, bottle green, black of any size as
approved by Engineer- in-Charge, in skirting, risers of steps and dados,
over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg/m2, including pointing in white
cement mixed with pigment of matching shade complete. | Sqm | 1161.3 | 1161.3 | 117.93 | False | None | None | False | None | False | 136952.109 | 0 | 3768821 | 141924 | None | code23 | Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :One coat with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in charge. | Sqm | 207.9 | 207.9 | 275.5755 | False | None | None | False | None | False | 57292.14645 | 0 | 3768822 | 141924 | None | code24 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:2010. | Mtr | 75.6 | 75.6 | 60.0 | False | None | None | False | None | False | 4536.0 | 0 | 3768823 | 141924 | None | code25 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. | Each | 159.6 | 159.6 | 6.0 | False | None | None | False | None | False | 957.6 | 0 | 3768824 | 141924 | None | code26 | Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. | Each | 784.35 | 784.35 | 3.0 | False | None | None | False | None | False | 2353.05 | 0 | 3768825 | 141924 | None | code27 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. | Nos | 131.25 | 131.25 | 12.0 | False | None | None | False | None | False | 1575.0 | 0 | 3768826 | 141924 | None | code28 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. | Each | 549.15 | 549.15 | 6.0 | False | None | None | False | None | False | 3294.9 | 0 | 3768827 | 141924 | None | code29 | Point wiring using copper wire with switch.: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Two outlet in a row, above 3m upto 6m from tapping point to out let via switches. | Point | 704.55 | 704.55 | 42.0 | False | None | None | False | None | False | 29591.1 | 0 | 3768828 | 141924 | None | code30 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments.4 mm2 | Mtr | 61.95 | 61.95 | 36.0 | False | None | None | False | None | False | 2230.2 | 0 | 3768829 | 141924 | None | code31 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. a) 6 Amps SP Switch | Nos | 45.15 | 45.15 | 6.0 | False | None | None | False | None | False | 270.9 | 0 | 3768830 | 141924 | None | code32 | b) 6 Amps 3 Way 5 Pin Socket | Nos | 68.25 | 68.25 | 6.0 | False | None | None | False | None | False | 409.5 | 0 | 3768831 | 141924 | None | code33 | c) 6 Amps Bakelite Ceiling Rose | Nos | 66.15 | 66.15 | 6.0 | False | None | None | False | None | False | 396.9 | 0 | 3768832 | 141924 | None | code34 | d) 6 Amps Lamps Holder | Nos | 66.15 | 66.15 | 6.0 | False | None | None | False | None | False | 396.9 | 0 | 3768833 | 141924 | None | code35 | Supplying & fixing of Surface mounting type retrofit type LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 1)18W-20W (T8). | Nos | 653.1 | 653.1 | 3.0 | False | None | None | False | None | False | 1959.3 | 0 |
| 1723545628000 | 0 | None | None | Other Works | Drilling of Borewell | 551908.2 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3768834 | 141925 | None | code01 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner orSchlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. PWD SR 2023-24 VOLUME NO V I No 12.4 P no - 140 | Each | 5552.4 | 5552.4 | 3.0 | False | None | None | False | None | False | 16657.2 | 0 | 3768835 | 141925 | None | code02 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )Borewell depth of 0 to 50 m PWD SR 2023-24 VOL- V I no -12.1.1 P no-139 | Mtr | 388.5 | 388.5 | 150.0 | False | None | None | False | None | False | 58275.0 | 0 | 3768836 | 141925 | None | code03 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )Borewell depth of 50 to 100 m PWD SR 2023-24 VOL- V I no -12.1.2 P no-139 Borewell 50-100 | Mtr | 487.2 | 487.2 | 150.0 | False | None | None | False | None | False | 73080.0 | 0 | 3768837 | 141925 | None | code04 | Sinking of Borewell of 165 mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )Borewell depth of 100 to 150 m PWD SR 2023-24 VOL- V I no -12.1.3 P no-139 Bore well 100-150 | Mtr | 517.65 | 517.65 | 15.0 | False | None | None | False | None | False | 7764.75 | 0 | 3768838 | 141925 | None | code05 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. PWD SR 2023-24 P N- 143 I NO- 12.32 | Mtr | 2029.65 | 2029.65 | 18.0 | False | None | None | False | None | False | 36533.7 | 0 | 3768839 | 141925 | None | code06 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments. PWD SR 2023-24 P NO -143 I NO- 12.33 | Each | 157.5 | 157.5 | 3.0 | False | None | None | False | None | False | 472.5 | 0 | 3768840 | 141925 | None | code07 | Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge PWD SR 2023-24 P NO -143 I NO- 12.34 | Each | 172.2 | 172.2 | 3.0 | False | None | None | False | None | False | 516.6 | 0 | 3768841 | 141925 | None | code08 | Providing, supplying to work site,Single Phase Submersible Pump Set sof 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments.(3.00 HP/2.2KW 9 STG) PWD SR 2023 -24 VOL-V P NO- 150 I NO- 13.9.1 | Each | 21118.65 | 21118.65 | 3.0 | False | None | None | False | None | False | 63355.95 | 0 | 3768842 | 141925 | None | code09 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments PWD SR 2023-24 VOL-V P NO- 155 I NO- 13.28 | Mtr | 577.5 | 577.5 | 285.0 | False | None | None | False | None | False | 164587.5 | 0 | 3768843 | 141925 | None | code10 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core 1x3x2.5 m2 (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. PWD SR 2023-24 VOL-V P NO- 154 I NO- 13.22.2 | Mtr | 89.25 | 89.25 | 300.0 | False | None | None | False | None | False | 26775.0 | 0 | 3768844 | 141925 | None | code11 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter Upto 6 HP pumps PWD SR 2023-24 VOL- V I NO-13.23.2 P NO- 155( 3 to 6 HP pumps) | Each | 10027.5 | 10027.5 | 3.0 | False | None | None | False | None | False | 30082.5 | 0 | 3768845 | 141925 | None | code12 | Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments 50mm dia PWD SR 2023-24 VOL-V P NO- 154 I NO- 13.24.1 | Each | 1312.5 | 1312.5 | 3.0 | False | None | None | False | None | False | 3937.5 | 0 | 3768846 | 141925 | None | code13 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments PWD SR 2023-24 VOL-V P NO- 154 I NO- 13.25.1 | Each | 1312.5 | 1312.5 | 3.0 | False | None | None | False | None | False | 3937.5 | 0 | 3768847 | 141925 | None | code14 | Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. PWD SR 2023-24 VOL-V P NO- 155 I NO- 13.25 | Kvar | 557.5 | 557.5 | 3.0 | False | None | None | False | None | False | 1672.5 | 0 | 3768848 | 141925 | None | code15 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. PWD SR 2023-24 VOL-V P NO- 155 I NO- 13.26 | Per 3 Poles | 1207.5 | 1207.5 | 3.0 | False | None | None | False | None | False | 3622.5 | 0 | 3768849 | 141925 | None | code16 | Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) 50mm dia PWD SR 2023-24 VOL-V P NO- 155 I NO- 13.27 | Each | 3202.5 | 3202.5 | 3.0 | False | None | None | False | None | False | 9607.5 | 0 | 3768850 | 141925 | None | code17 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work .PWD SR 2023-24 VOL-V P NO- 156 I NO- 13.32 | Job | 6825.0 | 6825.0 | 3.0 | False | None | None | False | None | False | 20475.0 | 0 | 3768851 | 141925 | None | code18 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work.PWD SR 2023-24 VOL-V P NO- 156 I NO- 13.34 | Job | 1522.5 | 1522.5 | 3.0 | False | None | None | False | None | False | 4567.5 | 0 | 3768852 | 141925 | None | code19 | Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI mark. PWD SR 2023-24 VOL-V P NO- 156 I NO- 13.30 | Set | 4725.0 | 4725.0 | 3.0 | False | None | None | False | None | False | 14175.0 | 0 | 3768853 | 141925 | None | code20 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. PWD SR 2023-24 VOL-V P NO- 157 I NO- 13.39 | Job | 3937.5 | 3937.5 | 3.0 | False | None | None | False | None | False | 11812.5 | 0 |
| 1723545628000 | 1 | None | None | Other Works | Construction Jalakhumba | 860930.41 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3768854 | 141926 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removalof stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In (all kinds of soils Depth upto 1.5) PWD COMMON SR 2023-24 VOLUM NO 1 ITEM NO 1.4 (1.4.1) PAGE NO 5 | Cum | 254.1 | 254.1 | 17.09 | False | None | None | False | None | False | 4342.569 | 0 | 3768855 | 141926 | None | code02 | Providing and laying in position Cement Concrete for levelling course forall works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (PWD Common DSR 2023-24 Volume 1 Page no 15 item no 2.1-2.1.2 Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 5.7 | False | None | None | False | None | False | 33899.04 | 0 | 3768856 | 141926 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD Common DSR 2023-24 P No.9/I No.5.1.1 Vol-2) | Cum | 5891.55 | 5891.55 | 51.3 | False | None | None | False | None | False | 302236.515 | 0 | 3768857 | 141926 | None | code04 | RCC hume pipe Circular pump house: Supplying precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm PWD WS and UGD DSR 2023-24 Volume V (P No: 116 I.No: 10.6, ). | Each | 17221.05 | 17221.05 | 19.0 | False | None | None | False | None | False | 327199.95 | 0 | 3768858 | 141926 | None | code05 | Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work. PWD WS and UGD DSR 2023-24Volume V (P No: 116 I.No:10.7, ). | Each | 1976.1 | 1976.1 | 19.0 | False | None | None | False | None | False | 37545.9 | 0 | 3768859 | 141926 | None | code06 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. PWD SR 2023-24 Vol 1 P No 15 I No 2.1.3 | Cum | 6288.45 | 6288.45 | 8.265 | False | None | None | False | None | False | 51974.03925 | 0 | 3768860 | 141926 | None | code07 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. [PWD Common DSR 2023-24 Volume 2 (P No: 44 I.No:8.19.1)] | Sqm | 167.75 | 167.75 | 84.36 | False | None | None | False | None | False | 14151.39 | 0 | 3768861 | 141926 | None | code08 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge 40 mm nominal dia Pipes (8.30)[ PWD SR Page No 46 item No 8.30 volum-2] | Sqm | 182.7 | 182.7 | 112.86 | False | None | None | False | None | False | 20619.522 | 0 | 3768862 | 141926 | None | code09 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall [PWD WS and CRS & BWSSB 2023-24 Volume II (P No: 122 I.No: 13.31.5 ) 40 mm nominal dia Pipes | Mtr | 562.8 | 562.8 | 19.0 | False | None | None | False | None | False | 10693.2 | 0 | 3768863 | 141926 | None | code10 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall [PWD WS and CRS & BWSSB 2023-24 Volume II (P No: 122 I.No: 13.31.2 )20 mm nominal dia Pipes | Mtr | 254.1 | 254.1 | 19.0 | False | None | None | False | None | False | 4827.9 | 0 | 3768864 | 141926 | None | code11 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Collor 20 mm dia. [2023-24 As Per Market Rate] | Nos | 23.1 | 23.1 | 38.0 | False | None | None | False | None | False | 877.8 | 0 | 3768865 | 141926 | None | code12 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Tee 20 mm dia. [2023-24 As Per Market Rate] | Nos | 46.2 | 46.2 | 38.0 | False | None | None | False | None | False | 1755.6 | 0 | 3768866 | 141926 | None | code13 | Providing and fixing Chlorinated Polyvinyl Chloride (PVC) Tap 20 mm dia. [2023-24 As Per Market Rate] | Each | 26.25 | 26.25 | 19.0 | False | None | None | False | None | False | 498.75 | 0 | 3768867 | 141926 | None | code14 | Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removalof stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In (all kinds of soils Depth upto 1.5) PWD COMMON SR 2023-24 VOLUM NO 1 ITEM NO 1.4 -(1.4.1) PAGE NO 5 | Cum | 254.1 | 254.1 | 30.78 | False | None | None | False | None | False | 7821.198 | 0 | 3768868 | 141926 | None | code15 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 4 Kg/m2 : 63mm (WS & UCD, CSR 2023-24, VOL-5, P No-120, NO-10.14.1 SOR | Rmtr | 122.85 | 122.85 | 209.0 | False | None | None | False | None | False | 25675.65 | 0 | 3768869 | 141926 | None | code16 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications, (CSR 2023-24 ,VOL-1 P NO-07, I NO 1.10) | Cum | 168.0 | 168.0 | 30.78 | False | None | None | False | None | False | 5171.04 | 0 | 3768870 | 141926 | None | code17 | Providing of Gunmetal Ball Valve of Non rising stem, screwed in bonnet, inside screw, integral seats, screwed female ends to IS:554/ BS 21/ ISO 7, Unbreakable sheet metal Handwheel, confoming to IS:778 Class-1 including provision of re-packing under pressure with appurtenances, complete : 150 mm nominal bore etc. complete PWD SR 2023-24 VOL -5 P NO- 35 I NO-2.60 | Each | 221.55 | 221.55 | 19.0 | False | None | None | False | None | False | 4209.45 | 0 | 3768871 | 141926 | None | code18 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 90 mm dia PVC Tee PWD SR 2023-24 VOL -5 P NO- 117 I NO-10.10.7 | Each | 179.55 | 179.55 | 19.0 | False | None | None | False | None | False | 3411.45 | 0 | 3768872 | 141926 | None | code19 | Supply and delivery at site special moulded variety PVC service saddles as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments mm dia PVC SERVICE SADDLESPWD SR 2023-24 VOL -5 P NO- 119 I NO-10.12.7 90 | Each | 211.55 | 211.55 | 19.0 | False | None | None | False | None | False | 4019.45 | 0 |
| 1723545628000 | 0 | None | None | Other Works | Construction Paver Work | 174937.97 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3768873 | 141927 | None | code01 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 19.5 | False | None | None | False | None | False | 9705.15 | 0 | 3768874 | 141927 | None | code02 | Providing and laying 80 mm thick factory made precast M-30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS15658 for Commercial Traffic Axle load repetitions upto 10 MSA & for Residential Streets of approved shape and colour,laid in required pattern and including over 40 mm thick compacted bedof coarse sand, filling the joints with fine sand etc.all complete asper the direction of Engineer-in-charge. (WMM/WBM Base to bepaid separately as per relevant technical specification) | Sqm | 1219.05 | 1219.05 | 130.0 | False | None | None | False | None | False | 158476.5 | 0 | 3768875 | 141927 | None | code03 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usagecharges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 1.035 | False | None | None | False | None | False | 6756.32475 | 0 |
| 1723545628000 | 1 | None | None | Other Works | Supply and Installation of High Mask Light | 2034258.91 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3768876 | 141928 | None | code01 | Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely | Mtr | 19.95 | 19.95 | 10.0 | False | None | None | False | None | False | 199.5 | 0 | 3768877 | 141928 | None | code02 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 1.5 mm2
694:2010 | Mtr | 27.3 | 27.3 | 20.0 | False | None | None | False | None | False | 546.0 | 0 | 3768878 | 141928 | None | code03 | 2.5 mm2 | Mtr | 44.1 | 44.1 | 30.0 | False | None | None | False | None | False | 1323.0 | 0 | 3768879 | 141928 | None | code04 | 4 mm2 | Mtr | 66.15 | 66.15 | 25.0 | False | None | None | False | None | False | 1653.75 | 0 | 3768880 | 141928 | None | code05 | 6 mm2 | Mtr | 96.6 | 96.6 | 30.0 | False | None | None | False | None | False | 2898.0 | 0 | 3768881 | 141928 | None | code06 | Fabrication, Supplying, Erection, Testing and Commissioning of ms long
Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot- dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data. | Each | 122850.0 | 122850.0 | 1.0 | False | None | None | False | None | False | 122850.0 | 0 | 3768882 | 141928 | None | code07 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for
working voltage upto 1100 Volts as per IS-694:1990 | Mtr | 118.65 | 118.65 | 140.0 | False | None | None | False | None | False | 16611.0 | 0 | 3768883 | 141928 | None | code08 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System
Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. | Each | 23171.4 | 23171.4 | 8.0 | False | None | None | False | None | False | 185371.2 | 0 | 3768884 | 141928 | None | code09 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over
existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires | Each | 170.1 | 170.1 | 8.0 | False | None | None | False | None | False | 1360.8 | 0 | 3768885 | 141928 | None | code10 | Supplying &fixingof Porcelai fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.PAGE NO-10 ,I -NO-.5.7 SR 202-22,PART - 1 | Each | 421.05 | 421.05 | 6.0 | False | None | None | False | None | False | 2526.3 | 0 | 3768886 | 141928 | None | code11 | Supplyand fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nut boult washers and wiring etc. complete with AC-3 Rating and as per IS-13947. Part - I chapter -5,Page No -11 | Each | 2370.9 | 2370.9 | 1.0 | False | None | None | False | None | False | 2370.9 | 0 | 3768887 | 141928 | None | code12 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C'Type curve indicator ON/OFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming | Each | 435.75 | 435.75 | 3.0 | False | None | None | False | None | False | 1307.25 | 0 | 3768888 | 141928 | None | code13 | 40 A TPN | Each | 3196.2 | 3196.2 | 2.0 | False | None | None | False | None | False | 6392.4 | 0 | 3768889 | 141928 | None | code14 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 210.0 | 210.0 | 2.0 | False | None | None | False | None | False | 420.0 | 0 | 3768890 | 141928 | None | code15 | Supplying ....A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board The busbar shall suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc.complete | Mtr | 2588.25 | 2588.25 | 0.4 | False | None | None | False | None | False | 1035.3 | 0 | 3768891 | 141928 | None | code16 | Supplying and fixing angle iron frame work fabricated out of MS.angle iron. and M.S Flat.....with bolts, washers etc.and painted with 2 coats of red oxide and then two coats of approved paint. | Mtr | 414.75 | 414.75 | 12.0 | False | None | None | False | None | False | 4977.0 | 0 | 3768892 | 141928 | None | code17 | Fabricating supplying and mounting MS box made out....SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., | Sqm | 0.52 | 0.52 | 22600.0 | False | None | None | False | None | False | 11752.0 | 0 | 3768893 | 141928 | None | code18 | Supplying and fixing Microprocessor based Electronit timer (without contactor Din Mounting using necessary bolts, nuts and washers etc.) 3-120sec setting.Page No-16,Part -I | Each | 2430.75 | 2430.75 | 1.0 | False | None | None | False | None | False | 2430.75 | 0 | 3768894 | 141928 | None | code19 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing
wood or metal box using N. F. screws. | Sqm | 0.36 | 0.36 | 18000.0 | False | None | None | False | None | False | 6480.0 | 0 | 3768895 | 141928 | None | code20 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. CIVIL SR 2022-23 OF V-I PAGE NO-8, I-1.13 | Cum | 352.8 | 352.8 | 15.625 | False | None | None | False | None | False | 5512.5 | 0 | 3768896 | 141928 | None | code21 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The ranite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as petechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) CIVIL SR 2022-23 OF V-I PAGE NO-15, I-2.1,2.1.2 | Cum | 5913.81 | 5913.81 | 0.78 | False | None | None | False | None | False | 4612.7718 | 0 | 3768897 | 141928 | None | code22 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) ) CIVIL SR 2022-23 OF V-I PAGE NO-13, I-2.1,2..21.1 | Cum | 6869.67 | 6869.67 | 3.31 | False | None | None | False | None | False | 22738.6077 | 0 | 3768898 | 141928 | None | code23 | Supplying, Fitting and Placing TMT Fe 500 & above
Reinforcement in Foundation/Substructure/Super structure complete as per Drawing and Technical Specifications.CIVIL SR 2022-23 OF V-III, PAGE NO-108 CHAPTER - 9,,l.No-9.3 | Tonne | 84204.54 | 84204.54 | 0.099 | False | None | None | False | None | False | 8336.24946 | 0 | 3768899 | 141928 | None | code24 | Supplying and fixing hylum plastic sheet 3mm Thick with necessary nitches for fixing switches,regulators etc., and fixing on existing wood or metal box using N. F.Screws Part - I chapter -2,Page No -6. | Sqm | 0.27 | 0.27 | 6800.0 | False | None | None | False | None | False | 1836.0 | 0 | 3768900 | 141928 | None | code25 | 1.1 kV,XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1,Armouring strip thickness and resistivity as per IS-3975 PART III,..PAGE NO -9 | Km | 148934.1 | 148934.1 | 0.38 | False | None | None | False | None | False | 56594.958 | 0 | 3768901 | 141928 | None | code26 | Laying of cable in Existing Trench/GI pipe/ Stone Ware /RCC Hume pipe using Wooden /Aluminum Rollers as directed by the departmental staff PART -IV, PAGE NO - 9 | Mtr | 16966.95 | 16966.95 | 0.3 | False | None | None | False | None | False | 5090.085 | 0 | 3768902 | 141928 | None | code27 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.PART -IV ,..PAGE NO - 8 | Sqm | 408.45 | 408.45 | 22.5 | False | None | None | False | None | False | 9190.125 | 0 | 3768903 | 141928 | None | code28 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr PART- IV , PAGE NO-8 | Sqm | 60.9 | 60.9 | 25.0 | False | None | None | False | None | False | 1522.5 | 0 | 3768904 | 141928 | None | code29 | Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.PART NO-IV, PAGR -8 | Mtr | 60.9 | 60.9 | 8.0 | False | None | None | False | None | False | 487.2 | 0 | 3768905 | 141928 | None | code30 | GI Pipe - 50 mm Dia PART -III, PAGE NO - 16 | Mtr | 402.15 | 402.15 | 8.0 | False | None | None | False | None | False | 3217.2 | 0 | 3768906 | 141928 | None | code31 | HDPE/PLB Pipe 50/42 mm PART-III PAGE-26 | Km | 87051.3 | 87051.3 | 0.1 | False | None | None | False | None | False | 8705.13 | 0 | 3768907 | 141928 | None | code32 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg PART-III, PAGE NO-17 | No | 808.5 | 808.5 | 3.0 | False | None | None | False | None | False | 2425.5 | 0 | 3768908 | 141928 | None | code33 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each PART-III PAGE NO-17 | No | 693.0 | 693.0 | 2.0 | False | None | None | False | None | False | 1386.0 | 0 | 3768909 | 141928 | None | code34 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag PART-III PAGE NO-17 | Bag | 318.15 | 318.15 | 2.0 | False | None | None | False | None | False | 636.3 | 0 | 3768910 | 141928 | None | code35 | 10 Sqmm | No | 3.15 | 3.15 | 36.0 | False | None | None | False | None | False | 113.4 | 0 | 3768911 | 141928 | None | code36 | 16 Sqmm | No | 3.15 | 3.15 | 12.0 | False | None | None | False | None | False | 37.8 | 0 | 3768912 | 141928 | None | code37 | Digging of Pit for providing GI Pipe type Earthing LABOUR RATE PART -IV PAGE NO - 1 | Pit | 606.9 | 606.9 | 3.0 | False | None | None | False | None | False | 1820.7 | 0 | 3768913 | 141928 | None | code38 | 8 SWG GI Wire MT - PER KG (4.064 mm Dia), Std Wt: 125 Kg/KM PART - III , ..PAGE NO - 3 | Pit | 81742.5 | 81742.5 | 0.02 | False | None | None | False | None | False | 1634.85 | 0 | 3768914 | 141928 | None | code39 | Brass Cable Gland PART -III ,..PAGE NO -25 | No | 80.85 | 80.85 | 2.0 | False | None | None | False | None | False | 161.7 | 0 | 3768915 | 141928 | None | code40 | Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely | Mtr | 19.95 | 19.95 | 10.0 | False | None | None | False | None | False | 199.5 | 0 | 3768916 | 141928 | None | code41 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 1.5 mm2
694:2010 | Mtr | 27.3 | 27.3 | 20.0 | False | None | None | False | None | False | 546.0 | 0 | 3768917 | 141928 | None | code42 | 2.5 mm2 | Mtr | 44.1 | 44.1 | 30.0 | False | None | None | False | None | False | 1323.0 | 0 | 3768918 | 141928 | None | code43 | 4 mm2 | Mtr | 66.15 | 66.15 | 25.0 | False | None | None | False | None | False | 1653.75 | 0 | 3768919 | 141928 | None | code44 | 6 mm2 | Mtr | 96.6 | 96.6 | 30.0 | False | None | None | False | None | False | 2898.0 | 0 | 3768920 | 141928 | None | code45 | Fabrication, Supplying, Erection, Testing and Commissioning of ms long
Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot- dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data. | Each | 122850.0 | 122850.0 | 1.0 | False | None | None | False | None | False | 122850.0 | 0 | 3768921 | 141928 | None | code46 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for
working voltage upto 1100 Volts as per IS-694:1990 | Mtr | 118.65 | 118.65 | 140.0 | False | None | None | False | None | False | 16611.0 | 0 | 3768922 | 141928 | None | code47 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System
Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. | Each | 23171.4 | 23171.4 | 8.0 | False | None | None | False | None | False | 185371.2 | 0 | 3768923 | 141928 | None | code48 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over
existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires | Each | 170.1 | 170.1 | 8.0 | False | None | None | False | None | False | 1360.8 | 0 | 3768924 | 141928 | None | code49 | Supplying &fixingof Porcelai fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.PAGE NO-10 ,I -NO-.5.7 SR 202-22,PART - 1 | Each | 421.05 | 421.05 | 6.0 | False | None | None | False | None | False | 2526.3 | 0 | 3768925 | 141928 | None | code50 | Supplyand fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nut boult washers and wiring etc. complete with AC-3 Rating and as per IS-13947. Part - I chapter -5,Page No -11 | Each | 2370.9 | 2370.9 | 1.0 | False | None | None | False | None | False | 2370.9 | 0 | 3768926 | 141928 | None | code51 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C'Type curve indicator ON/OFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming | Each | 435.75 | 435.75 | 3.0 | False | None | None | False | None | False | 1307.25 | 0 | 3768927 | 141928 | None | code52 | 40 A TPN | Each | 3196.2 | 3196.2 | 2.0 | False | None | None | False | None | False | 6392.4 | 0 | 3768928 | 141928 | None | code53 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 210.0 | 210.0 | 2.0 | False | None | None | False | None | False | 420.0 | 0 | 3768929 | 141928 | None | code54 | Supplying ....A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board The busbar shall suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc.complete | Mtr | 2588.25 | 2588.25 | 0.4 | False | None | None | False | None | False | 1035.3 | 0 | 3768930 | 141928 | None | code55 | Supplying and fixing angle iron frame work fabricated out of MS.angle iron. and M.S Flat.....with bolts, washers etc.and painted with 2 coats of red oxide and then two coats of approved paint. | Mtr | 414.75 | 414.75 | 12.0 | False | None | None | False | None | False | 4977.0 | 0 | 3768931 | 141928 | None | code56 | Fabricating supplying and mounting MS box made out....SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., | Sqm | 0.52 | 0.52 | 22600.0 | False | None | None | False | None | False | 11752.0 | 0 | 3768932 | 141928 | None | code57 | Supplying and fixing Microprocessor based Electronit timer (without contactor Din Mounting using necessary bolts, nuts and washers etc.) 3-120sec setting.Page No-16,Part -I | Each | 2430.75 | 2430.75 | 1.0 | False | None | None | False | None | False | 2430.75 | 0 | 3768933 | 141928 | None | code58 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing
wood or metal box using N. F. screws. | Sqm | 0.36 | 0.36 | 18000.0 | False | None | None | False | None | False | 6480.0 | 0 | 3768934 | 141928 | None | code59 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. CIVIL SR 2022-23 OF V-I PAGE NO-8, I-1.13 | Cum | 352.8 | 352.8 | 15.625 | False | None | None | False | None | False | 5512.5 | 0 | 3768935 | 141928 | None | code60 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The ranite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as petechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) CIVIL SR 2022-23 OF V-I PAGE NO-15, I-2.1,2.1.2 | Cum | 5913.81 | 5913.81 | 0.78 | False | None | None | False | None | False | 4612.7718 | 0 | 3768936 | 141928 | None | code61 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) ) CIVIL SR 2022-23 OF V-I PAGE NO-13, I-2.1,2..21.1 | Cum | 6869.67 | 6869.67 | 3.31 | False | None | None | False | None | False | 22738.6077 | 0 | 3768937 | 141928 | None | code62 | Supplying, Fitting and Placing TMT Fe 500 & above
Reinforcement in Foundation/Substructure/Super structure complete as per Drawing and Technical Specifications.CIVIL SR 2022-23 OF V-III, PAGE NO-108 CHAPTER - 9,,l.No-9.3 | Tonne | 84204.54 | 84204.54 | 0.099 | False | None | None | False | None | False | 8336.24946 | 0 | 3768938 | 141928 | None | code63 | Supplying and fixing hylum plastic sheet 3mm Thick with necessary nitches for fixing switches,regulators etc., and fixing on existing wood or metal box using N. F.Screws Part - I chapter -2,Page No -6. | Sqm | 0.27 | 0.27 | 6800.0 | False | None | None | False | None | False | 1836.0 | 0 | 3768939 | 141928 | None | code64 | 1.1 kV,XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1,Armouring strip thickness and resistivity as per IS-3975 PART III,..PAGE NO -9 | Km | 148934.1 | 148934.1 | 0.38 | False | None | None | False | None | False | 56594.958 | 0 | 3768940 | 141928 | None | code65 | Laying of cable in Existing Trench/GI pipe/ Stone Ware /RCC Hume pipe using Wooden /Aluminum Rollers as directed by the departmental staff PART -IV, PAGE NO - 9 | Mtr | 16966.95 | 16966.95 | 0.3 | False | None | None | False | None | False | 5090.085 | 0 | 3768941 | 141928 | None | code66 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.PART -IV ,..PAGE NO - 8 | Sqm | 408.45 | 408.45 | 22.5 | False | None | None | False | None | False | 9190.125 | 0 | 3768942 | 141928 | None | code67 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr PART- IV , PAGE NO-8 | Sqm | 60.9 | 60.9 | 25.0 | False | None | None | False | None | False | 1522.5 | 0 | 3768943 | 141928 | None | code68 | Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.PART NO-IV, PAGR -8 | Mtr | 60.9 | 60.9 | 8.0 | False | None | None | False | None | False | 487.2 | 0 | 3768944 | 141928 | None | code69 | GI Pipe - 50 mm Dia PART -III, PAGE NO - 16 | Mtr | 402.15 | 402.15 | 8.0 | False | None | None | False | None | False | 3217.2 | 0 | 3768945 | 141928 | None | code70 | HDPE/PLB Pipe 50/42 mm PART-III PAGE-26 | Km | 87051.3 | 87051.3 | 0.1 | False | None | None | False | None | False | 8705.13 | 0 | 3768946 | 141928 | None | code71 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg PART-III, PAGE NO-17 | No | 808.5 | 808.5 | 3.0 | False | None | None | False | None | False | 2425.5 | 0 | 3768947 | 141928 | None | code72 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each PART-III PAGE NO-17 | No | 693.0 | 693.0 | 2.0 | False | None | None | False | None | False | 1386.0 | 0 | 3768948 | 141928 | None | code73 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag PART-III PAGE NO-17 | Bag | 318.15 | 318.15 | 2.0 | False | None | None | False | None | False | 636.3 | 0 | 3768949 | 141928 | None | code74 | 10 Sqmm | No | 3.15 | 3.15 | 36.0 | False | None | None | False | None | False | 113.4 | 0 | 3768950 | 141928 | None | code75 | 16 Sqmm | No | 3.15 | 3.15 | 12.0 | False | None | None | False | None | False | 37.8 | 0 | 3768951 | 141928 | None | code76 | Digging of Pit for providing GI Pipe type Earthing LABOUR RATE PART -IV PAGE NO - 1 | Pit | 606.9 | 606.9 | 3.0 | False | None | None | False | None | False | 1820.7 | 0 | 3768952 | 141928 | None | code77 | 8 SWG GI Wire MT - PER KG (4.064 mm Dia), Std Wt: 125 Kg/KM PART - III , ..PAGE NO - 3 | Pit | 81742.5 | 81742.5 | 0.02 | False | None | None | False | None | False | 1634.85 | 0 | 3768953 | 141928 | None | code78 | Brass Cable Gland PART -III ,..PAGE NO -25 | No | 80.85 | 80.85 | 2.0 | False | None | None | False | None | False | 161.7 | 0 | 3768954 | 141928 | None | code79 | Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely | Mtr | 19.95 | 19.95 | 10.0 | False | None | None | False | None | False | 199.5 | 0 | 3768955 | 141928 | None | code80 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 1.5 mm2
694:2010 | Mtr | 27.3 | 27.3 | 20.0 | False | None | None | False | None | False | 546.0 | 0 | 3768956 | 141928 | None | code81 | 2.5 mm2 | Mtr | 44.1 | 44.1 | 30.0 | False | None | None | False | None | False | 1323.0 | 0 | 3768957 | 141928 | None | code82 | 4 mm2 | Mtr | 66.15 | 66.15 | 25.0 | False | None | None | False | None | False | 1653.75 | 0 | 3768958 | 141928 | None | code83 | 6 mm2 | Mtr | 96.6 | 96.6 | 30.0 | False | None | None | False | None | False | 2898.0 | 0 | 3768959 | 141928 | None | code84 | Fabrication, Supplying, Erection, Testing and Commissioning of ms long
Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot- dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data. | Each | 122850.0 | 122850.0 | 1.0 | False | None | None | False | None | False | 122850.0 | 0 | 3768960 | 141928 | None | code85 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for
working voltage upto 1100 Volts as per IS-694:1990 | Mtr | 118.65 | 118.65 | 140.0 | False | None | None | False | None | False | 16611.0 | 0 | 3768961 | 141928 | None | code86 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System
Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. | Each | 23171.4 | 23171.4 | 8.0 | False | None | None | False | None | False | 185371.2 | 0 | 3768962 | 141928 | None | code87 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over
existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires | Each | 170.1 | 170.1 | 8.0 | False | None | None | False | None | False | 1360.8 | 0 | 3768963 | 141928 | None | code88 | Supplying &fixingof Porcelai fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.PAGE NO-10 ,I -NO-.5.7 SR 202-22,PART - 1 | Each | 421.05 | 421.05 | 6.0 | False | None | None | False | None | False | 2526.3 | 0 | 3768964 | 141928 | None | code89 | Supplyand fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nut boult washers and wiring etc. complete with AC-3 Rating and as per IS-13947. Part - I chapter -5,Page No -11 | Each | 2370.9 | 2370.9 | 1.0 | False | None | None | False | None | False | 2370.9 | 0 | 3768965 | 141928 | None | code90 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C'Type curve indicator ON/OFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming | Each | 435.75 | 435.75 | 3.0 | False | None | None | False | None | False | 1307.25 | 0 | 3768966 | 141928 | None | code91 | 40 A TPN | Each | 3196.2 | 3196.2 | 2.0 | False | None | None | False | None | False | 6392.4 | 0 | 3768967 | 141928 | None | code92 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 210.0 | 210.0 | 2.0 | False | None | None | False | None | False | 420.0 | 0 | 3768968 | 141928 | None | code93 | Supplying ....A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board The busbar shall suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc.complete | Mtr | 2588.25 | 2588.25 | 0.4 | False | None | None | False | None | False | 1035.3 | 0 | 3768969 | 141928 | None | code94 | Supplying and fixing angle iron frame work fabricated out of MS.angle iron. and M.S Flat.....with bolts, washers etc.and painted with 2 coats of red oxide and then two coats of approved paint. | Mtr | 414.75 | 414.75 | 12.0 | False | None | None | False | None | False | 4977.0 | 0 | 3768970 | 141928 | None | code95 | Fabricating supplying and mounting MS box made out....SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., | Sqm | 0.52 | 0.52 | 22600.0 | False | None | None | False | None | False | 11752.0 | 0 | 3768971 | 141928 | None | code96 | Supplying and fixing Microprocessor based Electronit timer (without contactor Din Mounting using necessary bolts, nuts and washers etc.) 3-120sec setting.Page No-16,Part -I | Each | 2430.75 | 2430.75 | 1.0 | False | None | None | False | None | False | 2430.75 | 0 | 3768972 | 141928 | None | code97 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing
wood or metal box using N. F. screws. | Sqm | 0.36 | 0.36 | 18000.0 | False | None | None | False | None | False | 6480.0 | 0 | 3768973 | 141928 | None | code98 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. CIVIL SR 2022-23 OF V-I PAGE NO-8, I-1.13 | Cum | 352.8 | 352.8 | 15.625 | False | None | None | False | None | False | 5512.5 | 0 | 3768974 | 141928 | None | code99 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The ranite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as petechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) CIVIL SR 2022-23 OF V-I PAGE NO-15, I-2.1,2.1.2 | Cum | 5913.81 | 5913.81 | 0.78 | False | None | None | False | None | False | 4612.7718 | 0 | 3768975 | 141928 | None | code100 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) ) CIVIL SR 2022-23 OF V-I PAGE NO-13, I-2.1,2..21.1 | Cum | 6869.67 | 6869.67 | 3.31 | False | None | None | False | None | False | 22738.6077 | 0 | 3768976 | 141928 | None | code101 | Supplying, Fitting and Placing TMT Fe 500 & above
Reinforcement in Foundation/Substructure/Super structure complete as per Drawing and Technical Specifications.CIVIL SR 2022-23 OF V-III, PAGE NO-108 CHAPTER - 9,,l.No-9.3 | Tonne | 84204.54 | 84204.54 | 0.099 | False | None | None | False | None | False | 8336.24946 | 0 | 3768977 | 141928 | None | code102 | Supplying and fixing hylum plastic sheet 3mm Thick with necessary nitches for fixing switches,regulators etc., and fixing on existing wood or metal box using N. F.Screws Part - I chapter -2,Page No -6. | Sqm | 0.27 | 0.27 | 6800.0 | False | None | None | False | None | False | 1836.0 | 0 | 3768978 | 141928 | None | code103 | 1.1 kV,XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1,Armouring strip thickness and resistivity as per IS-3975 PART III,..PAGE NO -9 | Km | 148934.1 | 148934.1 | 0.38 | False | None | None | False | None | False | 56594.958 | 0 | 3768979 | 141928 | None | code104 | Laying of cable in Existing Trench/GI pipe/ Stone Ware /RCC Hume pipe using Wooden /Aluminum Rollers as directed by the departmental staff PART -IV, PAGE NO - 9 | Mtr | 16966.95 | 16966.95 | 0.3 | False | None | None | False | None | False | 5090.085 | 0 | 3768980 | 141928 | None | code105 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.PART -IV ,..PAGE NO - 8 | Sqm | 408.45 | 408.45 | 22.5 | False | None | None | False | None | False | 9190.125 | 0 | 3768981 | 141928 | None | code106 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr PART- IV , PAGE NO-8 | Sqm | 60.9 | 60.9 | 25.0 | False | None | None | False | None | False | 1522.5 | 0 | 3768982 | 141928 | None | code107 | Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.PART NO-IV, PAGR -8 | Mtr | 60.9 | 60.9 | 8.0 | False | None | None | False | None | False | 487.2 | 0 | 3768983 | 141928 | None | code108 | GI Pipe - 50 mm Dia PART -III, PAGE NO - 16 | Mtr | 402.15 | 402.15 | 8.0 | False | None | None | False | None | False | 3217.2 | 0 | 3768984 | 141928 | None | code109 | HDPE/PLB Pipe 50/42 mm PART-III PAGE-26 | Km | 87051.3 | 87051.3 | 0.1 | False | None | None | False | None | False | 8705.13 | 0 | 3768985 | 141928 | None | code110 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg PART-III, PAGE NO-17 | No | 808.5 | 808.5 | 3.0 | False | None | None | False | None | False | 2425.5 | 0 | 3768986 | 141928 | None | code111 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each PART-III PAGE NO-17 | No | 693.0 | 693.0 | 2.0 | False | None | None | False | None | False | 1386.0 | 0 | 3768987 | 141928 | None | code112 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag PART-III PAGE NO-17 | Bag | 318.15 | 318.15 | 2.0 | False | None | None | False | None | False | 636.3 | 0 | 3768988 | 141928 | None | code113 | 10 Sqmm | No | 3.15 | 3.15 | 36.0 | False | None | None | False | None | False | 113.4 | 0 | 3768989 | 141928 | None | code114 | 16 Sqmm | No | 3.15 | 3.15 | 12.0 | False | None | None | False | None | False | 37.8 | 0 | 3768990 | 141928 | None | code115 | Digging of Pit for providing GI Pipe type Earthing LABOUR RATE PART -IV PAGE NO - 1 | Pit | 606.9 | 606.9 | 3.0 | False | None | None | False | None | False | 1820.7 | 0 | 3768991 | 141928 | None | code116 | 8 SWG GI Wire MT - PER KG (4.064 mm Dia), Std Wt: 125 Kg/KM PART - III , ..PAGE NO - 3 | Pit | 81742.5 | 81742.5 | 0.02 | False | None | None | False | None | False | 1634.85 | 0 | 3768992 | 141928 | None | code117 | Brass Cable Gland PART -III ,..PAGE NO -25 | No | 80.85 | 80.85 | 2.0 | False | None | None | False | None | False | 161.7 | 0 | 3768993 | 141928 | None | code118 | Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely | Mtr | 19.95 | 19.95 | 10.0 | False | None | None | False | None | False | 199.5 | 0 | 3768994 | 141928 | None | code119 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 1.5 mm2
694:2010 | Mtr | 27.3 | 27.3 | 20.0 | False | None | None | False | None | False | 546.0 | 0 | 3768995 | 141928 | None | code120 | 2.5 mm2 | Mtr | 44.1 | 44.1 | 30.0 | False | None | None | False | None | False | 1323.0 | 0 | 3768996 | 141928 | None | code121 | 4 mm2 | Mtr | 66.15 | 66.15 | 25.0 | False | None | None | False | None | False | 1653.75 | 0 | 3768997 | 141928 | None | code122 | 6 mm2 | Mtr | 96.6 | 96.6 | 30.0 | False | None | None | False | None | False | 2898.0 | 0 | 3768998 | 141928 | None | code123 | Fabrication, Supplying, Erection, Testing and Commissioning of ms long
Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot- dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data. | Each | 122850.0 | 122850.0 | 1.0 | False | None | None | False | None | False | 122850.0 | 0 | 3768999 | 141928 | None | code124 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for
working voltage upto 1100 Volts as per IS-694:1990 | Mtr | 118.65 | 118.65 | 140.0 | False | None | None | False | None | False | 16611.0 | 0 | 3769000 | 141928 | None | code125 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System
Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. | Each | 23171.4 | 23171.4 | 8.0 | False | None | None | False | None | False | 185371.2 | 0 | 3769001 | 141928 | None | code126 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over
existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires | Each | 170.1 | 170.1 | 8.0 | False | None | None | False | None | False | 1360.8 | 0 | 3769002 | 141928 | None | code127 | Supplying &fixingof Porcelai fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.PAGE NO-10 ,I -NO-.5.7 SR 202-22,PART - 1 | Each | 421.05 | 421.05 | 6.0 | False | None | None | False | None | False | 2526.3 | 0 | 3769003 | 141928 | None | code128 | Supplyand fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nut boult washers and wiring etc. complete with AC-3 Rating and as per IS-13947. Part - I chapter -5,Page No -11 | Each | 2370.9 | 2370.9 | 1.0 | False | None | None | False | None | False | 2370.9 | 0 | 3769004 | 141928 | None | code129 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C'Type curve indicator ON/OFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming | Each | 435.75 | 435.75 | 3.0 | False | None | None | False | None | False | 1307.25 | 0 | 3769005 | 141928 | None | code130 | 40 A TPN | Each | 3196.2 | 3196.2 | 2.0 | False | None | None | False | None | False | 6392.4 | 0 | 3769006 | 141928 | None | code131 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 210.0 | 210.0 | 2.0 | False | None | None | False | None | False | 420.0 | 0 | 3769007 | 141928 | None | code132 | Supplying ....A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board The busbar shall suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc.complete | Mtr | 2588.25 | 2588.25 | 0.4 | False | None | None | False | None | False | 1035.3 | 0 | 3769008 | 141928 | None | code133 | Supplying and fixing angle iron frame work fabricated out of MS.angle iron. and M.S Flat.....with bolts, washers etc.and painted with 2 coats of red oxide and then two coats of approved paint. | Mtr | 414.75 | 414.75 | 12.0 | False | None | None | False | None | False | 4977.0 | 0 | 3769009 | 141928 | None | code134 | Fabricating supplying and mounting MS box made out....SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., | Sqm | 0.52 | 0.52 | 22600.0 | False | None | None | False | None | False | 11752.0 | 0 | 3769010 | 141928 | None | code135 | Supplying and fixing Microprocessor based Electronit timer (without contactor Din Mounting using necessary bolts, nuts and washers etc.) 3-120sec setting.Page No-16,Part -I | Each | 2430.75 | 2430.75 | 1.0 | False | None | None | False | None | False | 2430.75 | 0 | 3769011 | 141928 | None | code136 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing
wood or metal box using N. F. screws. | Sqm | 0.36 | 0.36 | 18000.0 | False | None | None | False | None | False | 6480.0 | 0 | 3769012 | 141928 | None | code137 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. CIVIL SR 2022-23 OF V-I PAGE NO-8, I-1.13 | Cum | 352.8 | 352.8 | 15.625 | False | None | None | False | None | False | 5512.5 | 0 | 3769013 | 141928 | None | code138 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The ranite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as petechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) CIVIL SR 2022-23 OF V-I PAGE NO-15, I-2.1,2.1.2 | Cum | 5913.81 | 5913.81 | 0.78 | False | None | None | False | None | False | 4612.7718 | 0 | 3769014 | 141928 | None | code139 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) ) CIVIL SR 2022-23 OF V-I PAGE NO-13, I-2.1,2..21.1 | Cum | 6869.67 | 6869.67 | 3.31 | False | None | None | False | None | False | 22738.6077 | 0 | 3769015 | 141928 | None | code140 | Supplying, Fitting and Placing TMT Fe 500 & above
Reinforcement in Foundation/Substructure/Super structure complete as per Drawing and Technical Specifications.CIVIL SR 2022-23 OF V-III, PAGE NO-108 CHAPTER - 9,,l.No-9.3 | Tonne | 84204.54 | 84204.54 | 0.099 | False | None | None | False | None | False | 8336.24946 | 0 | 3769016 | 141928 | None | code141 | Supplying and fixing hylum plastic sheet 3mm Thick with necessary nitches for fixing switches,regulators etc., and fixing on existing wood or metal box using N. F.Screws Part - I chapter -2,Page No -6. | Sqm | 0.27 | 0.27 | 6800.0 | False | None | None | False | None | False | 1836.0 | 0 | 3769017 | 141928 | None | code142 | 1.1 kV,XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1,Armouring strip thickness and resistivity as per IS-3975 PART III,..PAGE NO -9 | Km | 148934.1 | 148934.1 | 0.38 | False | None | None | False | None | False | 56594.958 | 0 | 3769018 | 141928 | None | code143 | Laying of cable in Existing Trench/GI pipe/ Stone Ware /RCC Hume pipe using Wooden /Aluminum Rollers as directed by the departmental staff PART -IV, PAGE NO - 9 | Mtr | 16966.95 | 16966.95 | 0.3 | False | None | None | False | None | False | 5090.085 | 0 | 3769019 | 141928 | None | code144 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.PART -IV ,..PAGE NO - 8 | Sqm | 408.45 | 408.45 | 22.5 | False | None | None | False | None | False | 9190.125 | 0 | 3769020 | 141928 | None | code145 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr PART- IV , PAGE NO-8 | Sqm | 60.9 | 60.9 | 25.0 | False | None | None | False | None | False | 1522.5 | 0 | 3769021 | 141928 | None | code146 | Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.PART NO-IV, PAGR -8 | Mtr | 60.9 | 60.9 | 8.0 | False | None | None | False | None | False | 487.2 | 0 | 3769022 | 141928 | None | code147 | GI Pipe - 50 mm Dia PART -III, PAGE NO - 16 | Mtr | 402.15 | 402.15 | 8.0 | False | None | None | False | None | False | 3217.2 | 0 | 3769023 | 141928 | None | code148 | HDPE/PLB Pipe 50/42 mm PART-III PAGE-26 | Km | 87051.3 | 87051.3 | 0.1 | False | None | None | False | None | False | 8705.13 | 0 | 3769024 | 141928 | None | code149 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg PART-III, PAGE NO-17 | No | 808.5 | 808.5 | 3.0 | False | None | None | False | None | False | 2425.5 | 0 | 3769025 | 141928 | None | code150 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each PART-III PAGE NO-17 | No | 693.0 | 693.0 | 2.0 | False | None | None | False | None | False | 1386.0 | 0 | 3769026 | 141928 | None | code151 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag PART-III PAGE NO-17 | Bag | 318.15 | 318.15 | 2.0 | False | None | None | False | None | False | 636.3 | 0 | 3769027 | 141928 | None | code152 | 10 Sqmm | No | 3.15 | 3.15 | 36.0 | False | None | None | False | None | False | 113.4 | 0 | 3769028 | 141928 | None | code153 | 16 Sqmm | No | 3.15 | 3.15 | 12.0 | False | None | None | False | None | False | 37.8 | 0 | 3769029 | 141928 | None | code154 | Digging of Pit for providing GI Pipe type Earthing LABOUR RATE PART -IV PAGE NO - 1 | Pit | 606.9 | 606.9 | 3.0 | False | None | None | False | None | False | 1820.7 | 0 | 3769030 | 141928 | None | code155 | 8 SWG GI Wire MT - PER KG (4.064 mm Dia), Std Wt: 125 Kg/KM PART - III , ..PAGE NO - 3 | Pit | 81742.5 | 81742.5 | 0.02 | False | None | None | False | None | False | 1634.85 | 0 | 3769031 | 141928 | None | code156 | Brass Cable Gland PART -III ,..PAGE NO -25 | No | 80.85 | 80.85 | 2.0 | False | None | None | False | None | False | 161.7 | 0 |
|
|
---|