createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723202046568
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1690.00
emd135000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose05-09-2024 16:30:00
tenderQueryClose29-08-2024 16:00:00
technicalBidOpen06-09-2024 17:00:00
publishedDate09-08-2024 17:49:04
publishedByPostTMC_CO_LGS
publishedByUserKPE17429 - RADDI RAYANA GOUDA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonBasavaraj
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8867048670
tenderSupplierListNone
tenderSchedule
createdTs1723202046604
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT25909
titleConstructionn of Proposed 6TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED) SY No-40/3 in Lingasugur TMC Limit
descriptionConstructionn of Proposed 6TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED) SY No-40/3 in Lingasugur TMC Limi
categoryWORKS
categoryTextWorks
ecv6750000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2374
locationNameDMA Town Municipal Council Lingasaguru
provisionalAmount6750000.0
groupOverheadTotal1080193.15
fileNumberTMC/LNG/MRF/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17232020470000NoneNoneBuildingsConstructionn of Proposed 6TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED) SY No-40/3 in Lingasugur TMC Limit5669806.85
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3738596139332Nonecode01KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum107.1107.156.87FalseNoneNoneFalseNoneFalse6090.7770
3738597139332Nonecode02KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5947.25947.244.67FalseNoneNoneFalseNoneFalse265661.4240
3738598139332Nonecode03KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum7322.47322.419.64FalseNoneNoneFalseNoneFalse143811.9360
3738599139332Nonecode04KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum11340.011340.08.41FalseNoneNoneFalseNoneFalse95369.40
3738600139332Nonecode05KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum7322.47322.449.41FalseNoneNoneFalseNoneFalse361799.7840
3738601139332Nonecode06KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum9820.89820.85.94FalseNoneNoneFalseNoneFalse58335.5520
3738602139332Nonecode07KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)Tonne93929.3593929.357.432FalseNoneNoneFalseNoneFalse698082.92920
3738603139332Nonecode08KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6708.456708.4528.22FalseNoneNoneFalseNoneFalse189312.4590
3738604139332Nonecode09KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum497.7497.7322.51FalseNoneNoneFalseNoneFalse160513.2270
3738605139332Nonecode10KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1292.551292.55145.44FalseNoneNoneFalseNoneFalse187988.4720
3738606139332Nonecode11KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2)Sqm309.75309.75303.84FalseNoneNoneFalseNoneFalse94114.440
3738607139332Nonecode12Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kgs118.65118.6519518.0FalseNoneNoneFalseNoneFalse2315810.70
3738608139332Nonecode13Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm596.4596.4951.97FalseNoneNoneFalseNoneFalse567754.9080
3738609139332Nonecode14KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2)Sqm105.0105.0303.84FalseNoneNoneFalseNoneFalse31903.20
3738610139332Nonecode15KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)Sqm76.6576.65145.44FalseNoneNoneFalseNoneFalse11147.9760
3738611139332Nonecode16KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)Sqm76.6576.65145.44FalseNoneNoneFalseNoneFalse11147.9760
3738612139332Nonecode17KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm2764.652764.6514.76FalseNoneNoneFalseNoneFalse40806.2340
3738613139332Nonecode18KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)No25920.325920.32.0FalseNoneNoneFalseNoneFalse51840.60
3738614139332Nonecode19KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2)Kgs474.6474.6240.0FalseNoneNoneFalseNoneFalse113904.00
3738615139332Nonecode20Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2. cu=100%lcs).In 4P MCCB,all Poles should have protection for Short-Cicrcuit/OverLoad.For Microprocessor MCCB S Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (P.No.17, I.No.5.15.1 in CSR Electrical SR Volume-6 2023-24) Three Pole- 100 A 25 kA (P.No.17, I.No.5.15.1 in CSR Electrical SR Volume-6 2023-24)Each6390.36390.31.0FalseNoneNoneFalseNoneFalse6390.30
3738616139332Nonecode21Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA.(P.No.21, I.No.5.46.1 & 5.46.6 in CSR Electrical SR Volume-6 2023-24)Each8911.358911.351.0FalseNoneNoneFalseNoneFalse8911.350
3738617139332Nonecode2216-32 A SP (P.No.21, I.No.5.46.1 in CSR Electrical SR Volume-6 2023-24)Each220.5220.51.0FalseNoneNoneFalseNoneFalse220.50
3738618139332Nonecode2363 A TP (P.No.21, I.No. 5.46.6 in CSR Electrical SR Volume-6 2023-24)Each1254.751254.751.0FalseNoneNoneFalseNoneFalse1254.750
3738619139332Nonecode24Supplying 100 A 4 x 30 x 6 mm Aluminium Strips A rated 3 phase with neutral busbar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The busbar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.(P.No.20, I.No.5.40.1 in CSR Electrical SR Volume-6 2023-24)Mtr2588.252588.2520.0FalseNoneNoneFalseNoneFalse51765.00
3738620139332NoneCode25Supplying and fixing angle iron frame work fabricated out of M.S.angle iron and M.S.Flat 40 x 40 x 6 mmwith bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.(P.No.20, I.No.5.41.1 in CSR Electrical SR Volume-6 2023-24)Mtr320.25320.2510.0FalseNoneNoneFalseNoneFalse3202.50
3738621139332NoneCode26Fabricating supplying and mounting MS box made out SWG suitable for floor/wall mounting,fully weather proof with provision for better heat dissipation,provided with hinged front cover,equipped with tamper proof locking arrangements,with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete.(P.No.20, I.No.5.42.1 in CSR Electrical SR Volume-6 2023-24)Sq CM0.530.5320000.0FalseNoneNoneFalseNoneFalse10600.00
3738622139332Nonecode27Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nuts,washers and wiring etc., complete with AC-3 Rating and as per IS-13947.(P.No.15 , I.No.5.13.1 in CSR Electrical SR Volume-6 2023-24)Each1354.51354.55.0FalseNoneNoneFalseNoneFalse6772.50
3738623139332Nonecode28Supplying and fixing Micro processor Based Astro nomical timer Switch with using necessary bolts, nuts and washers.(P.No.21, I.No.5.48 in CSR Electrical SR Volume-6 2023-24)Each5085.155085.153.0FalseNoneNoneFalseNoneFalse15255.450
3738624139332Nonecode29Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc.,(P.No.22, I.No.5.53 in CSR Electrical SR Volume-6 2023-24)Each1396.51396.53.0FalseNoneNoneFalseNoneFalse4189.50
3738625139332Nonecode30Supplying and fixing of metal clad industrial plugs and sockets. (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24) 3pole+earth 440V PLUG-32 Amps 16 Amps (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24)Each474.74474.742.0FalseNoneNoneFalseNoneFalse949.480
3738626139332Nonecode31Supplying and fixing of metal clad industrial plugs and sockets. (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24) 3pole+earth 440V PLUG-32 Amps 32 Amps (P.No.9, I.No.3.13.4 in CSR Electrical SR Volume-6 2023-24)Each640.35640.352.0FalseNoneNoneFalseNoneFalse1280.70
3738627139332Nonecode32Supplying,fixing and wiring 0to30 A Direct Reading AC analog type Ammeter.(P.No.18, I.No.5.24 in CSR Electrical SR Volume-6 2023-24)Each488.25488.254.0FalseNoneNoneFalseNoneFalse1953.00
3738628139332Nonecode33Supplying,fixing and wiring 0 to 600 V 96x96mm AC Voltmeter on existing panel/wood board.(P.No.18, I.No.5.22 in CSR Electrical SR Volume-6 2023-24)Each474.6474.61.0FalseNoneNoneFalseNoneFalse474.60
3738629139332Nonecode34Supplying,fixing and wiring rotary selector switch suitable for Ammeter.(P.No.19, I.No.5.27 in CSR Electrical SR Volume-6 2023-24)Each210.0210.04.0FalseNoneNoneFalseNoneFalse840.00
3738630139332Nonecode35Supplying, fixing and wiring rotary selector switch suitable for Voltmeter.(P.No.19, I.No.5.28 in CSR Electrical SR Volume-6 2023-24)Each168.0168.01.0FalseNoneNoneFalseNoneFalse168.00
3738631139332Nonecode36Supplying,fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.(P.No.19, I.No.5.34 in CSR Electrical SR Volume-6 2023-24)Each590.1590.14.0FalseNoneNoneFalseNoneFalse2360.40
3738632139332Nonecode37Supplying and fixing digital frequency meter with latest micro controller technology,ultra bright 4digit LED display,from 30-500VAC and optional or relay output for high/low frequency and wiringcomplete.(P.No.19, I.No.5.32 in CSR Electrical SR Volume-6 2023-24)Each1023.751023.751.0FalseNoneNoneFalseNoneFalse1023.750
3738633139332Nonecode38Supplying,fixing and wiring heavy duty low voltage capacitors conforming to IS2834.3 phase,400/440V grade,for power factor improvement of rotating machineries like induction motor.(P.No.19, I.No.5.37 in CSR Electrical SR Volume-6 2023-24)Kvar504.0504.05.0FalseNoneNoneFalseNoneFalse2520.00
3738634139332Nonecode391.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. ESCOM SR 2023-24 I No. 32.11 Pg.13Km187921.65187921.650.03FalseNoneNoneFalseNoneFalse5637.64950
3738635139332Nonecode404Cx25 Sqmm Al Ar cable.ESCOM SR 2023-24 I No. 32.08 Pg.13Km188836.2188836.20.02FalseNoneNoneFalseNoneFalse3776.7240
3738636139332Nonecode414Cx16 Sqmm Al Ar cable ESCOM SR 2023-24 I No. 32.05 Pg.13Km148934.1148934.10.02FalseNoneNoneFalseNoneFalse2978.6820
3738637139332Nonecode424Cx10 Sqmm Cu Ar cable.ESCOM SR 2023-24 I No. 32.03 Pg.13Km123904.5123904.50.02FalseNoneNoneFalseNoneFalse2478.090
3738638139332Nonecode43Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 sqmm ESCOM SR 2023-24 I No. 21.05 Pg.52Km21930.221930.20.06FalseNoneNoneFalseNoneFalse1315.8120
3738639139332Nonecode44Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 Sqmm .ESCOM SR 2023-24 I No. 21.06 Pg.52Km32656.9532656.950.03FalseNoneNoneFalseNoneFalse979.70850
3738640139332Nonecode45Earth Work Excavation for pipeline/cables by manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shorting, strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a redius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc.. in layers not exceeding 20 cm in depth, consolidated each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.(P.No.06, I.No 1.6.1 in KPWD CSR volume-1, 2023-24Cum498.52498.526.75FalseNoneNoneFalseNoneFalse3365.010
3738641139332Nonecode46Cable Joint and wiring (for HT & LT UG Cable). LT UG Cable. Heat shrinkable Type Terminations ESCOM SR 2023-24 I No. 22.13 Pg.53Set199.5199.52.0FalseNoneNoneFalseNoneFalse399.00
3738642139332Nonecode4735 to 95 Sqmm .ESCOM SR 2023-24 I No. 22.14 Pg.53Set98.798.712.0FalseNoneNoneFalseNoneFalse1184.40
3738643139332Nonecode48Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Electrical SR-2023-24, ITEM NO:1.1 ,CH-1, PAGE NO-2 19/20mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-2Mtr72.4572.4520.0FalseNoneNoneFalseNoneFalse1449.00
3738644139332Nonecode49Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Electrical SR-2023-24, ITEM NO:1.1 ,CH-1, PAGE NO-2 25mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-2Mtr85.0585.0520.0FalseNoneNoneFalseNoneFalse1701.00
3738645139332Nonecode50Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Electrical SR-2023-24, ITEM NO:1.1 ,CH-1, PAGE NO-2 32mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-2Mtr111.3111.320.0FalseNoneNoneFalseNoneFalse2226.00
3738646139332Nonecode51Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Electrical SR-2023-24, ITEM NO:1.1 ,CH-1, PAGE NO-240mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2Mtr156.45156.4520.0FalseNoneNoneFalseNoneFalse3129.00
3738647139332Nonecode52Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR-2023-24, ITEM NO:2.1,CH-1, PAGE NO-5 Short point upto 3Mtr from tapping point to out let via switch. PWD Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-1, PAGE NO-5No299.45299.4510.0FalseNoneNoneFalseNoneFalse2994.50
3738648139332Nonecode53Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR-2023-24, ITEM NO:2.1,CH-1, PAGE NO-5 Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch .PWD Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-1, PAGE NO-5No413.7413.710.0FalseNoneNoneFalseNoneFalse4137.00
3738649139332Nonecode54Long point above 6Mtr upto 10Mtr from tapping point to out let via switch.PWD Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-1, PAGE NO-5No598.5598.55.0FalseNoneNoneFalseNoneFalse2992.50
3738650139332Nonecode55Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to outlet via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5No743.4743.45.0FalseNoneNoneFalseNoneFalse3717.00
3738651139332Nonecode56Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-1, PAGE NO-5No1086.751086.755.0FalseNoneNoneFalseNoneFalse5433.750
3738652139332Nonecode57Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. PWD Electrical SR-2023-24, ITEM NO:2.3 ,CH-1, PAGE NO-5 1.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-1, PAGE NO-5Mtr19.9519.95180.0FalseNoneNoneFalseNoneFalse3591.00
3738653139332Nonecode58Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. PWD Electrical SR-2023-24, ITEM NO:2.3 ,CH-1, PAGE NO-5 1.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-1, PAGE NO-5Mtr27.327.3100.0FalseNoneNoneFalseNoneFalse2730.00
3738654139332Nonecode59Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. PWD Electrical SR-2023-24, ITEM NO:2.3 ,CH-1, PAGE NO-5 2.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-1, PAGE NO-5Mtr44.144.1150.0FalseNoneNoneFalseNoneFalse6615.00
3738655139332Nonecode60Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. PWD Electrical SR-2023-24, ITEM NO:2.3 ,CH-1, PAGE NO-54.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-1, PAGE NO-5Mtr66.1566.1575.0FalseNoneNoneFalseNoneFalse4961.250
3738656139332Nonecode61Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. PWD Electrical SR-2023-24, ITEM NO:2.3 ,CH-1, PAGE NO-5 6.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-1, PAGE NO-5Mtr94.7694.7650.0FalseNoneNoneFalseNoneFalse4738.00
3738657139332Nonecode62Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing metal/PVC box. 10 - 12 Module Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.6 ,CH-3, PAGE NO-8No361.2361.25.0FalseNoneNoneFalseNoneFalse1806.00
3738658139332Nonecode633 Module Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.2 ,CH-3, PAGE NO-5No169.05169.054.0FalseNoneNoneFalseNoneFalse676.20
3738659139332Nonecode64Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete.No130.2130.25.0FalseNoneNoneFalseNoneFalse651.00
3738660139332Nonecode65Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. 10-12 Way PWD Electrical SR-2023-24, ITEM NO:3.3.6 ,CH-3, PAGE NO-8No274.05274.055.0FalseNoneNoneFalseNoneFalse1370.250
3738661139332Nonecode66Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Switches & sockets outlets in Existing modular box. PWD Electrical SR-2023-24, ITEM NO:3.6 ,CH-3, PAGE NO-9 6A one way switch.PWD Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-9No107.1107.12.0FalseNoneNoneFalseNoneFalse214.20
3738662139332Nonecode67Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Switches & sockets outlets in Existing modular box. PWD Electrical SR-2023-24, ITEM NO:3.6 ,CH-3, PAGE NO-9 6A 3 way socket.PWD Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-9No179.55179.552.0FalseNoneNoneFalseNoneFalse359.10
3738663139332Nonecode68Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Switches & sockets outlets in Existing modular box. PWD Electrical SR-2023-24, ITEM NO:3.6 ,CH-3, PAGE NO-9 6/16A Universal socket.PWD Electrical SR-2023-24, ITEM NO:3.6.10 ,CH-3, PAGE NO-9No247.8247.82.0FalseNoneNoneFalseNoneFalse495.60
3738664139332Nonecode69Supply of LEDStreetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising ofanti glare clear diffuserwith Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @Lumen Maintenanceof70 , maximum lightintensityshouldbebetween 60degrees to 70degrees. CCT 5500K, IP66optical andelectrical compartment &impact resistanceof complete luminaire IK08. Power Factor 0.9 withmains,SurgeProtection-Min5KValongwithOver voltage/Overload, short circuit/miss-wiring protection. Compatible for pole mounting with outer dia of 40 mm to 50mm.Universal Voltagedriver tooperatewidevoltage range from100Vto 270V 50 60Hz application. Compliance to IS 10322 IEC60598 LM79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site locationwith minimized minimal tools. LED Light fixture with .WSystem Power consumption. LED Efficiency 1301m w, nominal CRI 75. Luminaire manufacturer should have in-house facilityaccredited by NABL/CPRI any Government certified agency & Design & Development facility certified by ISO9001:2008. Housingwith supplierwordmark/name shallbe Engraved /Embossing on thediecast housing/Bodypart. Warranty of 2Years against any manufactur indefec two rkin gunder standard electrical conditionsas mentioned above should be given by LEDmanufacturer Cree Nichia Lumileds Osram make LED Source CSR Electrical SR-2023-24 ITEM NO11.8.2, PAGE NO-46No9960.39960.35.0FalseNoneNoneFalseNoneFalse49801.50
3738665139332Nonecode70GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI Strip.PWD Electrical SR-2023-24, ITEM NO:12.58.2 ,CH-12, PAGE NO-54Mtr86.186.140.0FalseNoneNoneFalseNoneFalse3444.00
3738666139332Nonecode712 mm thick perforated cable GI tray with one xisting MS angle support using necessary GI bolts/nuts and washer or welding as required.(PWD Electrical SR-2023-24, ITEM NO:12.59.2 ,CH-12, PAGE NO-55Mtr616.35616.3515.0FalseNoneNoneFalseNoneFalse9245.250
3738667139332Nonecode72Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GIwire of size asper lSI specification 7.3.3.of IS 732 using 12mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.PWD Electrical SR-2023-24, ITEM NO:12.56,CH-12, PAGE NO-54No3685.93685.91.0FalseNoneNoneFalseNoneFalse3685.90
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17232020480000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17232020480000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17232020480000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17232020480000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17232020480000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17232020630000NoneNoneELIGIBILITYAs per Bid DocumentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneSimilar nutura of work done certificatePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneQuatity wais work done certificatePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneEligible Registered PWD Contractor.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneIn the Last five years Period acheived at least two financial years an average annual financial turnover Rs. 67.50 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneAnnuval Turnover Certificate atlest 5Year Above the EstimateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLine of CreditFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneVaild Pan and GST Registration certificateOthersGST
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Eligible Registered PWD Contractor.TrueTechnical Bid
Similar Nature of Work Done Certificate that is 50 Percent of Estimate Cost ie. Rs. 33.75 LakhsTrueTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
In the Last five years Period acheived at least two financial years an average annual financial turnover Rs. 67.50 LakhsTrueTechnical Bid
Liquid assests and or availability of ceredit fecilities of not less than Rs.20.25 Lakhs Credit Lines/ letter of Credit certificate from nationlized or scheduled banks.TrueTechnical Bid
GST, VST Registration Certificate , PAN Card.TrueTechnical Bid
Less Rate Quoted amount in Shape of DD. In the Name of Chief Officer Town Municipal council LingasagurTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsRaichuruLingasaguruRaichurLINGSUGURIn LingasagurNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone