tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1724915185000 | 0 | None | None | Buildings | Construction of police station Grade-4 at Jayanagar in Tumkur district civil | 10034874.32 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3876616 | 148753 | None | VOL-I Item No 1.12Page No-8 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Sqm | 95.55 | 95.55 | 504.0 | False | None | None | False | None | False | 48157.2 | 0 | 3876617 | 148753 | None | VOL-I Item No 1.4.2Page No-5 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5m, but not exceeding 3 m | Cum | 185.85 | 185.85 | 76.0 | False | None | None | False | None | False | 14124.6 | 0 | 3876618 | 148753 | None | VOL-I Item No 1.5.1Page No-6 | Earth work excavation for Foundation by manual means for all Buildings,Bridges, Retaining walls, Abutment Piers and such similar works as per drawing and technical Specifications, including setting out, providing shoring & strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 271.95 | 271.95 | 177.41 | False | None | None | False | None | False | 48246.6495 | 0 | 3876619 | 148753 | None | Vol-I Item No2.1.3 Page No. 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregate | Cum | 6125.62 | 6125.62 | 94.27 | False | None | None | False | None | False | 577462.1974 | 0 | 3876620 | 148753 | None | Vol-I Item No 2.5.2 Page No. 16 | Providing and laying in Cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately ) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates for Grade Beam & Columns footings | Cum | 7185.02 | 7185.02 | 51.32 | False | None | None | False | None | False | 368735.2264 | 0 | 3876621 | 148753 | None | VOL-I Item No 1.9 Page No-7 | Filling available excavated earth ( excluding rock) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications No.KSB 2.9 | Cum | 168.0 | 168.0 | 346.0 | False | None | None | False | None | False | 58128.0 | 0 | 3876622 | 148753 | None | VOL-II Item No. 6.32 Page No. 17 ground floor | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1375.5 | 1375.5 | 432.09 | False | None | None | False | None | False | 594339.795 | 0 | 3876623 | 148753 | None | VOL-II Item No. 6.32 Page No. 17 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. For First Floor | Sqm | 1389.26 | 1389.26 | 253.48 | False | None | None | False | None | False | 352149.6248 | 0 | 3876624 | 148753 | None | VOL-II Item No. 6.34 Page No. 17 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1159.2 | 1159.2 | 215.69 | False | None | None | False | None | False | 250027.848 | 0 | 3876625 | 148753 | None | VOL-II Item No. 6.34 Page No. 17 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. FOR FF | Sqm | 1170.79 | 1170.79 | 68.39 | False | None | None | False | None | False | 80070.3281 | 0 | 3876626 | 148753 | None | Vol-I Item No 2.1.4 Page No. 15 | Providing and laying in position Cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement to be paid separately )Mix 1:3:6 M10 Design Mix Using 20 mm and down size graded crushed coarse aggregates GF | Cum | 6527.85 | 6527.85 | 4.4 | False | None | None | False | None | False | 28722.54 | 0 | 3876627 | 148753 | None | Vol-I Item No 2.1.4 Page No. 15 | Providing and laying in position Cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 M10 Design Mix Using 20 mm and down size graded crushed coarse aggregates First floor | Cum | 6593.13 | 6593.13 | 2.27 | False | None | None | False | None | False | 14966.4051 | 0 | 3876628 | 148753 | None | Vol-I Item No 2.5.2 Page No. 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement to be paid separately ) LINTEL | Cum | 11496.24 | 11496.24 | 5.15 | False | None | None | False | None | False | 59205.636 | 0 | 3876629 | 148753 | None | Vol-I Item No 2.5.2 Page No. 16 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , (The cost of steel reinforcement to be paid separately ) labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ROOF BEAMS | Cum | 11496.24 | 11496.24 | 14.19 | False | None | None | False | None | False | 163131.6456 | 0 | 3876630 | 148753 | None | Vol-I Item No 2.5.2 Page No. 16 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,(The cost of steel reinforcement to be paid separately ) labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for Concrete Stair case | Cum | 11496.24 | 11496.24 | 5.52 | False | None | None | False | None | False | 63459.2448 | 0 | 3876631 | 148753 | None | Vol-I Item No 2.5.2 Page No. 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately ) First floor intel | Cum | 11496.24 | 11496.24 | 2.67 | False | None | None | False | None | False | 30694.9608 | 0 | 3876632 | 148753 | None | Vol-I Item No 2.5.2 Page No. 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement to be paid separately )FF roof | Cum | 11496.24 | 11496.24 | 14.19 | False | None | None | False | None | False | 163131.6456 | 0 | 3876633 | 148753 | None | Vol-I Item No 2.5.2 Page No.16 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical (The cost of steel reinforcement to be paid separately ) specifications. for GF chajja
| Cum | 11496.24 | 11496.24 | 1.24 | False | None | None | False | None | False | 14255.3376 | 0 | 3876634 | 148753 | None | Vol-I Item No 2.5.2 Page No.16 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement to be paid separately ) for chajja FF | Cum | 11496.24 | 11496.24 | 0.66 | False | None | None | False | None | False | 7587.5184 | 0 | 3876635 | 148753 | None | Vol-I Item No 2.5.2 Page No.16 | Providing and laying in position Cement concrete M25 for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications(The cost of steel reinforcement to be paid separately ) for columns | Cum | 12214.76 | 12214.76 | 20.0 | False | None | None | False | None | False | 244295.2 | 0 | 3876636 | 148753 | None | Vol-I Item No 2.5.2 Page No.16 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement to be paid separately ) for columns FF | Cum | 12286.61 | 12286.61 | 12.48 | False | None | None | False | None | False | 153336.8928 | 0 | 3876637 | 148753 | None | Vol-I Item No 2.5.2 Page No.16 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately ) Roof slab
| Cum | 10777.73 | 10777.73 | 46.89 | False | None | None | False | None | False | 505367.7597 | 0 | 3876638 | 148753 | None | Vol-I Item No 2.5.2 Page No.16 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical (The cost of steel reinforcement to be paid separately ) specifications.FF SLAB | Cum | 10849.58 | 10849.58 | 24.25 | False | None | None | False | None | False | 263102.315 | 0 | 3876639 | 148753 | None | page-15 item no.4.21 | KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering (labour charges only) as per specifications. GF | Rmtr | 33.0 | 33.0 | 48.0 | False | None | None | False | None | False | 1584.0 | 0 | 3876640 | 148753 | None | Vol-II Item No 8.10 Page No. 43 | Providing 12mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per GF | Sqm | 339.15 | 339.15 | 641.0 | False | None | None | False | None | False | 217395.15 | 0 | 3876641 | 148753 | None | Vol-II Item No 8.10 Page No. 43 | Providing 12mm cement plaster with cement mortor 1:3 (1 cement:3 fine sand) including rounding of corroners where ever required smooth rendering,providing and removing scafolding including cost of materials, curring complete as per specification and as per directions of engineer in charge | Sqm | 342.54 | 342.54 | 163.0 | False | None | None | False | None | False | 55834.02 | 0 | 3876642 | 148753 | None | Vol-II Item No 8.9 Page No. 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 404.25 | 404.25 | 453.19 | False | None | None | False | None | False | 183202.0575 | 0 | 3876643 | 148753 | None | Vol-II Item No 8.9 Page No. 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge FF | Sqm | 416.85 | 416.85 | 264.26 | False | None | None | False | None | False | 110156.781 | 0 | 3876644 | 148753 | None | Vol-II Item No 8.10 Page No. 43 | Providing 12mm cement plaster with cement mortor 1:3 (1 cement:3 fine sand) including rounding of corroners where ever required smooth rendering,providing and removing scafolding including cost of materials, curring complete as per specification and as per directions of engineer in charge CIELING | Sqm | 423.94 | 423.94 | 263.0 | False | None | None | False | None | False | 111496.22 | 0 | 3876645 | 148753 | None | Vol-II Item No 8.10 Page No. 43 | Providing 12mm cement plaster with cement mortor 1:3 (1 cement:3 fine sand) including rounding of corroners where ever required smooth rendering,providing and removing scafolding including cost of materials, curring complete as per specification and as per directions of engineer in charge | Sqm | 427.33 | 427.33 | 79.0 | False | None | None | False | None | False | 33759.07 | 0 | 3876646 | 148753 | None | Vol-II Item No 8.5.2 Page No. 42 | Providing rough cement plastering 15mm thick in single coat with cement mortar to brick masonry for base of dadooing works with sand of approved quality, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.KSRB15-5.1 :do cement mortar 1:4 | Sqm | 480.38 | 480.38 | 107.0 | False | None | None | False | None | False | 51400.66 | 0 | 3876647 | 148753 | None | Vol-II Item No 8.5.2 Page No. 42 | Providing rough cement plastering 15mm thick in single coat with cement mortar to brick masonry for base of dadooing works with sand of approved quality, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.KSRB15-5.1 do cement mortar 1:4 | Sqm | 484.22 | 484.22 | 57.0 | False | None | None | False | None | False | 27600.54 | 0 | 3876648 | 148753 | None | Vol-II Item No 8.30Page No. 46 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 259.88 | 259.88 | 518.23 | False | None | None | False | None | False | 134677.6124 | 0 | 3876649 | 148753 | None | Vol-II Item No 8.30Page No. 46 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 264.08 | 264.08 | 281.9 | False | None | None | False | None | False | 74444.152 | 0 | 3876650 | 148753 | None | Vol-II Item No 8.51 Page No. 50 | Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered
wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge. WALL PUTTY | Sqm | 78.0 | 78.0 | 939.25 | False | None | None | False | None | False | 73261.5 | 0 | 3876651 | 148753 | None | Vol-II Item No 8.51 Page No. 50 | Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered
wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge. FF PUTY | Sqm | 78.0 | 78.0 | 261.17 | False | None | None | False | None | False | 20371.26 | 0 | 3876652 | 148753 | None | Vol-II Item No 8.30Page No. 46 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor | Sqm | 107.63 | 107.63 | 939.25 | False | None | None | False | None | False | 101091.4775 | 0 | 3876653 | 148753 | None | Vol-II Item No 8.30Page No. 46 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First floor First floor | Sqm | 107.63 | 107.63 | 261.17 | False | None | None | False | None | False | 28109.7271 | 0 | 3876654 | 148753 | None | Vol-II Item No. 12.89 Page No.111 | Providing & fixing of 2.5-track x 2-panel sliding windows made out of multi chambered UPVCMatching to RAL-9016) sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI renforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mmThe cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made | Sqm | 7070.7 | 7070.7 | 23.49 | False | None | None | False | None | False | 166090.743 | 0 | 3876655 | 148753 | None | Vol-II Item No. 12.89 Page No. 111 | Providing & fixing of 2.5-track x 2-panel sliding windows made out of multi chambered UPVCMatching to RAL-9016) sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI renforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mmThe cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made | Sqm | 7070.7 | 7070.7 | 11.34 | False | None | None | False | None | False | 80181.738 | 0 | 3876656 | 148753 | None | VOL-II Item No.11.34 A Page No.86 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 1810.98 | False | None | None | False | None | False | 347979.807 | 0 | 3876657 | 148753 | None | 11.28 volume 2 page 85 | Providing and fixing Stainless steel 304 grade for staircase railings, balconies, ramps, with hand rail 50mm dia 16 guage hollow pipe welded to vertical hollow 50mm dia pipe of 16 guage, stainless steel vertical pipe spaced at 1.20m regular intervals, and 5 Nos.of 25mm dia. stainless steel hollow horizontal pipe are welded to vertical 50mm dia hollow pipe. The entire assembly is fixed to staircase concrete by using expansion bolts by drilling concrete etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., | Kg | 593.25 | 593.25 | 315.0 | False | None | None | False | None | False | 186873.75 | 0 | 3876658 | 148753 | None | Vol-II Item No. 12.57.1 Page No. 105 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification. including cost of materials , labour chages for fixing fixtures.Etc with all lead and lift | Sqm | 4665.15 | 4665.15 | 14.04 | False | None | None | False | None | False | 65498.706 | 0 | 3876659 | 148753 | None | Vol-II Item No. 12.57.1 Page No. 105 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification. including cost of materials , labour chages for fixing fixtures.Etc with all lead and lift FF | Sqm | 4665.15 | 4665.15 | 12.3 | False | None | None | False | None | False | 57381.345 | 0 | 3876660 | 148753 | None | Vol-II Item No. 12.13.1 Page No. 100 | Providing wood frames of doors, windows, clerestory windows, ventilators and other frames wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps but including cost of materials labour HOM complete as per specifications. Specification do Sal wood frame | Cum | 103755.75 | 103755.75 | 0.71 | False | None | None | False | None | False | 73666.5825 | 0 | 3876661 | 148753 | None | Vol-II Item No. 12.13.1 Page No. 100 | Providing wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps but including cost of materialslabour HOM complete as per specifications. Specification | Cum | 103755.75 | 103755.75 | 0.48 | False | None | None | False | None | False | 49802.76 | 0 | 3876662 | 148753 | None | Vol-II Item No. 12.51 Page No. 104 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | No | 1066.8 | 1066.8 | 13.0 | False | None | None | False | None | False | 13868.4 | 0 | 3876663 | 148753 | None | Vol-II Item No. 12.51 Page No. 104 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | No | 1066.8 | 1066.8 | 10.0 | False | None | None | False | None | False | 10668.0 | 0 | 3876664 | 148753 | None | Vol-II Item No 9.22.2 page no 62 | Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water vabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints .Size of Tile 600x600 mm | Sqm | 1233.75 | 1233.75 | 281.54 | False | None | None | False | None | False | 347349.975 | 0 | 3876665 | 148753 | None | Vol-II Item No 9.22.2 page no 62 | Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water vabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints .Size of Tile 600x600 mm FOR FF | Sqm | 1246.09 | 1246.09 | 58.8 | False | None | None | False | None | False | 73270.092 | 0 | 3876666 | 148753 | None | Vol-II Item No 9.11page no 60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 1129.8 | 1129.8 | 26.17 | False | None | None | False | None | False | 29566.866 | 0 | 3876667 | 148753 | None | Vol-II Item No 9.11page no 60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 1141.1 | 1141.1 | 26.71 | False | None | None | False | None | False | 30478.781 | 0 | 3876668 | 148753 | None | 9.31 VOLUME 2 PAGE 64 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. | Sqm | 4133.85 | 4133.85 | 59.14 | False | None | None | False | None | False | 244475.889 | 0 | 3876669 | 148753 | None | Vol-II Item No 9.39 Page No. 65 | Providing skirting, dadooing, rises of steps with colour glazed tiles6mm thick on 10mm thick cement plaster 1:3 and jointed with whitecement slurry over existing rough plaster surface using glazed tiles ofapproved make and size including cost of materials, labour, completeas per specifications. | Sqm | 1155.0 | 1155.0 | 111.63 | False | None | None | False | None | False | 128932.65 | 0 | 3876670 | 148753 | None | Vol-I Item No 2.11.a Page No.18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 93929.85 | 93929.85 | 14.95 | False | None | None | False | None | False | 1404251.2575 | 0 | 3876671 | 148753 | None | Vol-I Item No 2.11.a Page No.18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and technical specification. FF | Tonne | 94876.92 | 94876.92 | 6.05 | False | None | None | False | None | False | 574005.366 | 0 | 3876672 | 148753 | None | Vol-II Item No 8.49 Page No. 49 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directionsof Engineer-in-charge. | cm | 4.2 | 4.2 | 5000.0 | False | None | None | False | None | False | 21000.0 | 0 | 3876673 | 148753 | None | page 117 Item no.15.34 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120 gm2 width, along route of walls chipped for services junction between RCC and brick walls including cost of materialslabour for fixing complete as per specifications. length of mesh only measured for pay | Rmtr | 31.0 | 31.0 | 373.6 | False | None | None | False | None | False | 11581.6 | 0 | 3876674 | 148753 | None | Vol-1 item 1.12 PG NO-8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5m, but not exceeding 3 m | Cum | 467.25 | 467.25 | 76.03 | False | None | None | False | None | False | 35525.0175 | 0 | 3876675 | 148753 | None | Vol 1 iteam 1.9 pg -7 | Filling available excavated earth ( excluding rock) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications No.KSB 2.9 | Cum | 279.3 | 279.3 | 346.0 | False | None | None | False | None | False | 96637.8 | 0 | 3876676 | 148753 | None | vol 1 Iteam 2.1.3 pg 15 | providing and laying in Cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement to be paid separately ) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates for Grade Beam & Columns footings plinth beam | Cum | 11496.24 | 11496.24 | 17.5 | False | None | None | False | None | False | 201184.2 | 0 | 3876677 | 148753 | None | vol 1 iteam 2.1.3 page 15 | providing and laying in Cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement to be paid separately ) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates for Grade Beam & Columns footings plinth beam | Cum | 6601.35 | 6601.35 | 15.1 | False | None | None | False | None | False | 99680.385 | 0 | 3876678 | 148753 | None | VOL1 Iteam 1 2.1.3 PAGE 15 | FF Screed concrete | Cum | 6667.36 | 6667.36 | 15.1 | False | None | None | False | None | False | 100677.136 | 0 | 3876679 | 148753 | None | page 15 iteam 4.21 | Extra for providing throating or drip moulding to R.C.C. chajja with plastering (labour charges only) With including all lead, lifts, loading and unloading & HOM charges, all other incidental charges required for completion of work as per approved specifications, designs, drawings etc., complete and directions of the Engineer in-charge of the work. Specification No. KBS | m | 33.0 | 33.0 | 48.0 | False | None | None | False | None | False | 1584.0 | 0 | 3876680 | 148753 | None | page15 iteam4.27 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20cms c to c both horizontally and vertially fixing chicken mesh for drop chajja, facia, backing to cup boards With including all lead, lifts, loading and unloading & HOM charges, all other incidental charges required for completion of work as per approved specifications, designs, drawings etc., complete and directions of the Engineer in-charge of the work. Specification No. KBS | Sqm | 1072.0 | 1072.0 | 16.0 | False | None | None | False | None | False | 17152.0 | 0 | 3876681 | 148753 | None | itam 4.55 page 20 | Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding cost of steel and fabrication charges) With including all lead, lifts, loading and unloading & HOM charges, all other incidental charges required for completion of work as per approved specifications, designs, drawings etc., complete and directions of the Engineer in-charge of the work. (It-no-4.55) | Sqm | 619.0 | 619.0 | 19.0 | False | None | None | False | None | False | 11761.0 | 0 | 3876682 | 148753 | None | page 20 iteam 4.55 | Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding cost of steel and fabrication charges) With including all lead, lifts, loading and unloading & HOM charges, all other incidental charges required for completion of work as per approved specifications, designs, drawings etc., complete and directions of the Engineer in-charge of the work. (It-no-4.55) | Sqm | 619.0 | 619.0 | 11.0 | False | None | None | False | None | False | 6809.0 | 0 | 3876683 | 148753 | None | page 9 iteam 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with
Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 12.3 | False | None | None | False | None | False | 85471.47 | 0 | 3876684 | 148753 | None | page 268 iteam 37.30 | Providing wall black boards in CM 1:3 with two coats of black paint including finishing etc., With including all lead, lifts, loading and unloading & HOM charges, all other incidental charges required for completion of work as per approved specifications, designs, drawings etc., complete and directions of the Engineer in-charge of the work.I( | Sqm | 781.0 | 781.0 | 31.68 | False | None | None | False | None | False | 24742.08 | 0 | 3876685 | 148753 | None | 8.64&8.34.1 vol-2 pno 52 | Providing and applying painting two coats (excluding priming coat) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand paperingWith including all lead, lifts, loading and unloading & HOM charges, all other incidental charges required for completion of work as per approved specifications, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Sqm | 105.0 | 105.0 | 59.89 | False | None | None | False | None | False | 6288.45 | 0 | 3876686 | 148753 | None | 8.64&8.34.1vol-2 pno 52 | Providing and applying painting two coats (excluding priming coat) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand paperingWith including all lead, lifts, loading and unloading & HOM charges, all other incidental charges required for completion of work as per approved specifications, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Sqm | 105.0 | 105.0 | 33.57 | False | None | None | False | None | False | 3524.85 | 0 | 3876687 | 148753 | None | NSR 1 | Providing Grooves in plasteringon walls 2.5 to mtrs 4 cms vide to the required depth in CM 1:3 including curing etc., With including all lead, lifts, loading and unloading & HOM charges, all other incidental charges required for completion of work as per approved specifications, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | m | 40.0 | 40.0 | 1425.6 | False | None | None | False | None | False | 57024.0 | 0 | 3876688 | 148753 | None | 215 vol 2 p no A19 | Providing and fixing to wall, ceiling and floor galvanised / mild steel tube 40mm dia nominal bore with fittings (medium grade weight 1.27kg/mtr) B classWith including all lead, lifts, loading and unloading & HOM charges, all other incidental charges required for completion of work as per approved specifications, designs, drawings etc., complete and directions of the Engineer in-charge of thework. Specification | m | 304.5 | 304.5 | 6.0 | False | None | None | False | None | False | 1827.0 | 0 | 3876689 | 148753 | None | NSR2 | Plantation of fruit trees | No | 1050.0 | 1050.0 | 10.0 | False | None | None | False | None | False | 10500.0 | 0 | 3876690 | 148753 | None | VOL II ITEAM 9.39 NO 65 | Providing skirting, dadooing, rises of steps with colour glazed tiles6mm thick on 10mm thick cement plaster 1:3 and jointed with whitecement slurry over existing rough plaster surface using glazed tiles ofapproved make and size including cost of materials, labour, completeas per specifications. FOR FF | Sqm | 1141.1 | 1141.1 | 26.71 | False | None | None | False | None | False | 30478.781 | 0 |
| 1724915185000 | 0 | None | None | Buildings | Construction of police station Grade-4 at Jayanagar in Tumkur district water supply | 524704.45 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3876691 | 148754 | None | VOL-I Item No 1.4.2Page No-5 | Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. -In all types of soil (P-8, I-2.23.1). | Cum | 493.5 | 493.5 | 32.0 | False | None | None | False | None | False | 15792.0 | 0 | 3876692 | 148754 | None | VOL-I Item No 1.9 Page No-7 | Filling available excavated earth ( excluding rock) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications | Cum | 168.0 | 168.0 | 32.0 | False | None | None | False | None | False | 5376.0 | 0 | 3876693 | 148754 | None | 13.31.4 | Providing and fixing chorinated poly vinyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work).25mm | Mtr | 257.5 | 257.5 | 100.0 | False | None | None | False | None | False | 25750.0 | 0 | 3876694 | 148754 | None | 13.33.6 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) 50mm pipes confirming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings , this including jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. 32mm | Rmtr | 232.78 | 232.78 | 90.0 | False | None | None | False | None | False | 20950.2 | 0 | 3876695 | 148754 | None | Vol-VItem No 13.31.3 Page No. | Providing and fixing chlorinated poly vinyl chloride ( CPVC ) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all C P V C plain and brass threaded fittings, including fixing the pipe with clamp at 1.00 mtrs spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement , and the cost of cutting chases & making good the same including testing of joints complete (concealed work including cutting chase and good the walls) 40mm | Rmtr | 335.78 | 335.78 | 60.0 | False | None | None | False | None | False | 20146.8 | 0 | 3876696 | 148754 | None | 13.4.1 113 | Providing and fixing in position brass gate valve with C.I wheel of approved quality screwed end NB including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification no of 25mmd | Nos | 973.0 | 973.0 | 4.0 | False | None | None | False | None | False | 3892.0 | 0 | 3876697 | 148754 | None | Vol-V Item No 13.70.3 | Providing and fixing to wall, ceiling and floor , medium density polythene pipes 6.00 kgf /sqcm working pressure mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of materials, labour charges, HOM of equipments and testing complete as per specifications.75MM | Rmtr | 444.96 | 444.96 | 60.0 | False | None | None | False | None | False | 26697.6 | 0 | 3876698 | 148754 | None | Vol-V Item No 13.70.5Page No. 49 | Providing and fixing to wall, ceiling and floor , medium density polyethylene pipes 6.00 kgf /sqcm working pressure outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of materials, labour charges, HOM of equipments and testing complete as per specifications.110mm | Mtr | 463.5 | 463.5 | 159.0 | False | None | None | False | None | False | 73696.5 | 0 | 3876699 | 148754 | None | Vol-V Item No 10.1.9 .7Page No. 113 | Providing and fixing to wall, ceiling and floor , medium density polyethylene pipes 6.00 kgf /sqcm working pressure outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of materials, labour charges, HOM of equipments and testing complete as per specifications160 mm dia | Rmtr | 645.81 | 645.81 | 50.0 | False | None | None | False | None | False | 32290.5 | 0 | 3876700 | 148754 | None | ol-II Item No. 14.35.1 Page No.127 | Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo IndianW.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms | Nos | 5255.25 | 5255.25 | 8.0 | False | None | None | False | None | False | 42042.0 | 0 | 3876701 | 148754 | None | pg 90 12.112.2 | Providing stone ware nani trap of approved quality and fixing in C C 1:2:4 and plastering with C M 1:3 where ever necessary
Size: 15 cm x 10 cm | Each | 293.55 | 293.55 | 10.0 | False | None | None | False | None | False | 2935.5 | 0 | 3876702 | 148754 | None | pg 269 item no.37.35 | Making wall bores in brick masonry walls up to 045 m width for soil water pipe including necessary scaffolding | Nos | 129.78 | 129.78 | 15.0 | False | None | None | False | None | False | 1946.7 | 0 | 3876703 | 148754 | None | pg 269 item no.37.36.2 | Making wall bores in stone masonry walls up to 0.45 m width for soil/water pipe including redoing with CM 1:4 and scaffolding. size: 60 cm to 90 cm width | Nos | 312.09 | 312.09 | 8.0 | False | None | None | False | None | False | 2496.72 | 0 | 3876704 | 148754 | None | 13.78, pg. no. 96 | Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 1996 with manhole lid and suitable locking arrangements making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials,labour, transport charges, HOM andtesting | Nos | 8467.0 | 8467.0 | 1.0 | False | None | None | False | None | False | 8467.0 | 0 | 3876705 | 148754 | None | 11.50.2, Pg. no. 73 | Constructing brick masonry inspection chamber 450x 450 mm , and 450 mm depth, clear dimension for pipeline with one or two inlets , using table moulded non- modular bricks of class designation 50 in cement mortar 1:5, CI cover with frame light duty 455 610mm total weight of cover with frame to be not less than 39 kgs weight fo cover 23kgs and weight of frame 15kg) RCC top slab with cement concrete M15 with 20mm and downsize granite metal, foundation concrete M5 with 40 mm and downsize granite metal inside plastering 12 mm cement on walls and bed concrete complete as per standard design including cost of materials,labour charges, curing complete as per specifications.450 | Nos | 5459.0 | 5459.0 | 6.0 | False | None | None | False | None | False | 32754.0 | 0 | 3876706 | 148754 | None | Volum 5 12.111 Pg. no. 90 | Providing & Fixing in position NP grating -7.5 cms to 15.00 cms dia grating 100mm dia | Nos | 154.5 | 154.5 | 8.0 | False | None | None | False | None | False | 1236.0 | 0 | 3876707 | 148754 | None | Vol-II Item No. 14.31 Page No.126 | Providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos | 1019.55 | 1019.55 | 8.0 | False | None | None | False | None | False | 8156.4 | 0 | 3876708 | 148754 | None | Vol-II Item No. 14.7.1Page No.122 | Providing and fixing white vitreous china clay, flat back wash basin with a single 15mm C.P brass pillar tap with C.I M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification | Nos | 4127.21 | 4127.21 | 8.0 | False | None | None | False | None | False | 33017.68 | 0 | 3876709 | 148754 | None | Vol-II Item No. 14.40.2 Page No.128 | Providing and fixing CP brass Towel rail 600 mm length, 20 mm dia, with CP brackets, fixed to wooden cleats with CP brass screws including cost of materials, labour complete as per specifications. | Nos | 399.0 | 399.0 | 8.0 | False | None | None | False | None | False | 3192.0 | 0 | 3876710 | 148754 | None | NSR | Providing and fixing CP. Health faucet with flexible hose,CP Angle valve, wall flange, supporting hook with screws, fixing materials and sealant to all sides of wall flange complete | Nos | 1390.5 | 1390.5 | 6.0 | False | None | None | False | None | False | 8343.0 | 0 | 3876711 | 148754 | None | NSR | Providing and fixing in position two way bib cock (with face plate) of approved quality 15 mm nominal bore including cost of all materials, labour and HOM of equipments with alll leads complete as per specifications | Nos | 1350.0 | 1350.0 | 6.0 | False | None | None | False | None | False | 8100.0 | 0 | 3876712 | 148754 | None | NSR | Providing and fixing in position long body cock (with face plate) for shower control arrangements including the cost of all materials, labour and HOM of equipments etc complete as per directions of engineer in charg | Nos | 1350.0 | 1350.0 | 8.0 | False | None | None | False | None | False | 10800.0 | 0 | 3876713 | 148754 | None | NSR | Providing and fixing in position CP bib cock (with face plate) of approved quality 15 mm nominal bore including cost of all materials, labour and HOM of equipments with alll leads complete as per specifications | Nos | 1350.0 | 1350.0 | 8.0 | False | None | None | False | None | False | 10800.0 | 0 | 3876714 | 148754 | None | NSR | Providing and fixing in position Jaquar / Hindware / Parry ware or equivalent Angle stop cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all lead, lift, loading, unloading & HOM charges etc., complete as per specifications. and directions of the Engineer-in-charge of work. | Each | 1250.0 | 1250.0 | 20.0 | False | None | None | False | None | False | 25000.0 | 0 | 3876715 | 148754 | None | 11.50.2 PG 73 | Constructing brick masonry inspection chamber 600x600 mm , and 450 mm depth, clear dimension for pipeline with one or two inlets , using table moulded non- modular bricks of class designation 50 in cement mortar 1:5, CI cover with frame light duty 455 610mm total weight of cover with frame to be not less than 39 kgs weight fo cover 23kgs and weight of frame 15kg) RCC top slab with cement concrete M15 with 20mm and downsize granite metal, foundation concrete M5 with 40 mm and downsize granite metal inside plastering 12 mm cement on walls and bed concrete complete as per standard design including cost of materials,labour charges, curing complete as per specifications. | Nos | 8744.7 | 8744.7 | 3.0 | False | None | None | False | None | False | 26234.1 | 0 | 3876716 | 148754 | None | page 73 iteam 11.37 | Constructing brick masonary circular type manhole 0.91m internal dia at bottom 0.91m deep and 0.56m dia at top with table moulded non modular bricks of 50 class designation 50 in cement mortor 1:4, inside cement plastered 12mm thick with cement mortor 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame (heavey duty, HD-20 graded designation) 560mm internal disametre confirming IS : 12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid separately) With including all lead, lifts, loading and unloading & HOM charges, all other incidental charges required for completion of work as per approved specifications, designs, drawings | Nos | 15146.15 | 15146.15 | 1.0 | False | None | None | False | None | False | 15146.15 | 0 | 3876717 | 148754 | None | page 81 iteam12.15 | Providing & fixing white vitreous china clay, flat back or half stal urinal basin of size 580x380x350mm with 5 litres PVC automatic flushing cistern, CI / MS brackets, standard flush pipe and CP brass spreaders with brass unions and GI clamps CI dtrap with outlet grating and other couplings in CP brass, painting of fittings and brackets, cutting and making good the wall and floor whereever required, including cost of materials, labour complete as per specifications. | Each | 5124.25 | 5124.25 | 4.0 | False | None | None | False | None | False | 20497.0 | 0 | 3876718 | 148754 | None | vol2 it no 14.1.1 PAGE121 | Providing and fixing white vitreous china clay, water closet Orissa pattern of size 580 x 440mm with integral type footrests, 100 mm S or P trap, 10 litre low level, P.V.C flushing cistern (all are approved make) with fittings, C.I/M.S brackets, 32 mm diameter flush pipe fittings and clamps, overflow arrangements with special and 25 mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specificationsWith including all lead, lifts, loading and unloading & HOM charges, all other incidental charges required for completion of work as per approved specifications, designs, drawings etc., complete and directions of the Engineer in-charge of the work | Pan | 4458.3 | 4458.3 | 2.0 | False | None | None | False | None | False | 8916.6 | 0 | 3876719 | 148754 | None | PAGE 99 ITEAM 13.87.6 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.)40mm nomial OD pipes (external work)With including all lead, lifts, loading and unloading & HOM charges, all other incidental charges required for completion of work as per approved specifications, designs, drawings etc., complete and directions of the Engineer in-charge of the 50mm nomial OD pipes | m | 444.96 | 444.96 | 50.0 | False | None | None | False | None | False | 22248.0 | 0 | 3876720 | 148754 | None | PAG 63 ITEAM 13.65.3 | Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 32mm dia nominal bore With including all lead, lifts, loading and unloading & HOM charges, all other incidental charges required for completion of work as per approved specifications, designs, drawings etc., complete and directions of the Engineer in-charge of the work . Specifications No. KBS 13.2.6 / 13.3 | Each | 973.0 | 973.0 | 8.0 | False | None | None | False | None | False | 7784.0 | 0 |
| 1724915185000 | 0 | None | None | Buildings | Construction of police station Grade-4 at Jayanagar in Tumkur district sump | 256273.12 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3876721 | 148755 | None | VOL-I Item No 1.4.2Page No-5 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & otherappurtenaces required to complete the work Depth exceeding 1.5m, but not exceeding3 | Cum | 195.3 | 195.3 | 48.0 | False | None | None | False | None | False | 9374.4 | 0 | 3876722 | 148755 | None | VOL-I Item No 1.5.1Page No-6 | Earth work excavation for Foundation by manual means for all Buildings,Bridges, Retaining walls, Abutment Piers and such similar works as per drawing and technical Specifications, including setting out, providing shoring & strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 508.2 | 508.2 | 20.16 | False | None | None | False | None | False | 10245.312 | 0 | 3876723 | 148755 | None | Vol-I Item No2.1.3 Page No. 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.
Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregate | Cum | 5947.2 | 5947.2 | 3.6 | False | None | None | False | None | False | 21409.92 | 0 | 3876724 | 148755 | None | Vol-I Item No 2.4.3 Page No. 16 | Providing and laying in Cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately )M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates Footing | Cum | 6542.55 | 6542.55 | 10.45 | False | None | None | False | None | False | 68369.6475 | 0 | 3876725 | 148755 | None | VOL-I Item No 1.9 Page No-7 | Filling available excavated earth ( excluding rock) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications | Cum | 168.0 | 168.0 | 68.0 | False | None | None | False | None | False | 11424.0 | 0 | 3876726 | 148755 | None | Vol-II Item No 8.9 Page No. 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 413.7 | 413.7 | 57.24 | False | None | None | False | None | False | 23680.188 | 0 | 3876727 | 148755 | None | Vol-II Item No 8.1.1Page No. 41 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 344.4 | 344.4 | 19.25 | False | None | None | False | None | False | 6629.7 | 0 | 3876728 | 148755 | None | Vol-I Item No 2.11.a Page No.18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 93929.85 | 93929.85 | 0.97 | False | None | None | False | None | False | 91111.9545 | 0 | 3876729 | 148755 | None | 127PAGE ITEAM13.55 Vol-2 | Providing & fixing 60x60 cms MS inspection Door with necessary M S frame made out of M S angle 50X50X6 mm and M S shutter of 31.5mm of B G 10 thick with hinges on top and locking arrangements painting etc complete as specification. | Nos | 7780.5 | 7780.5 | 1.0 | False | None | None | False | None | False | 7780.5 | 0 | 3876730 | 148755 | None | NSR | Providing & fixing MS ladder 45cm wide with 65X65X6mm sized angle iron and 20mm M S Bars at 25cm centre to centre with necessary supports as directed and angle iron of same section at braces including fixing in ground with C C 1:2:4 bed and 2 coats of non poisonous anticorrosive bituminous paint as directed (including inserting in the angle iron and welding ) outside | Mtr | 1785.0 | 1785.0 | 3.5 | False | None | None | False | None | False | 6247.5 | 0 |
| 1724915185000 | 0 | None | None | Buildings | Construction of police station Grade-4 at Jayanagar in Tumkur district BORE WELL | 261220.36 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3876731 | 148756 | None | CSR 2022 Vol-V, It. No.O040A Pg No.151 | Geophysical investigation at site for sinking borewells for supplyingdrinking water to the habitation either through the Hand Pump MWS orP.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geologicalformation. Geophysical investigation of existing ground water in thevicinity, its quality, quantity and acceptability of the users, indicatingthe location of the site, recommended depth of casing pipe required toseal the top unconsolidated formation including an extra depth of 1.0metre in consolidated formation for proper seating of casing pipe, depthof drilling required to cover full depth of aquifer proposed to be tapped,probable yield and other information required including transportationof instruments and accessories to work site, engaging technical personaland labour required etc. NOTE: 1) Additional rate on item 1&2 isallowed for drilling in over burden and fixing Casing pipes beyond 20 M(for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%,b) Above 30 M - 30% (Measurement of overburden is restricted to thedepth of casing pipe fixed excluding initial depth of 20M and projectionabove ground level). 2) A sum of Rs. 100/- is to be deducted for DryBorewell towards yield test. | Each | 5446.64 | 5446.64 | 1.0 | False | None | None | False | None | False | 5446.64 | 0 | 3876732 | 148756 | None | CSR 2022 Vol-V, It. No.O020A Pg No.151 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig ofcapacity 250 PSIG & above 900 CMF and above, in all strata of earth,including over burden upto 20M, fixing of casing pipes, collars and capwith ncessary cutting, threading and welding including transportation ofrig and supporting vehicles, crew charges, cost of consumables, cost ofyield test at the final depth with a minimum working of compressor forone hour etc. complete. The cost excludes the cost of casing pipes,collars and caps etc.) for: UP 50 MTRS | Rmtr | 381.1 | 381.1 | 50.0 | False | None | None | False | None | False | 19055.0 | 0 | 3876733 | 148756 | None | CSR 2022 Vol-V, It. No.O020B Pg No.151 | Above 50 -100mts | Rmtr | 477.92 | 477.92 | 50.0 | False | None | None | False | None | False | 23896.0 | 0 | 3876734 | 148756 | None | CSR 2022 Vol-V, It. No.O020D Pg No.151 | Above 100 - 150 mts | Rmtr | 507.79 | 507.79 | 50.0 | False | None | None | False | None | False | 25389.5 | 0 | 3876735 | 148756 | None | CSR 2022 Vol-V, It. No.O020E Pg No.151 | Above 150 - 200 mts | Rmtr | 589.16 | 589.16 | 50.0 | False | None | None | False | None | False | 29458.0 | 0 | 3876736 | 148756 | None | CSR 2022 Vol-V, It. No.O020F Pg No.151 | Above 250 - 300mts | Rmtr | 762.2 | 762.2 | 50.0 | False | None | None | False | None | False | 38110.0 | 0 | 3876737 | 148756 | None | CSR 2022 Vol-II, It. No.336 Pg No.A22 | M.S. pipe 160 mm dia casing pipe | Rmtr | 987.77 | 987.77 | 40.0 | False | None | None | False | None | False | 39510.8 | 0 | 3876738 | 148756 | None | CSR 2022 Vol-V, It. No.1818,D&R Pg No.54 | Providing and fixing MS casing collars | Each | 154.5 | 154.5 | 6.0 | False | None | None | False | None | False | 927.0 | 0 | 3876739 | 148756 | None | CSR 2022 Vol-V, SL. No.1105,5888 Pg No.32 | MS casing caps | Each | 168.92 | 168.92 | 1.0 | False | None | None | False | None | False | 168.92 | 0 | 3876740 | 148756 | None | CSR 2022 Vol-V, It. No.O020F Pg No.151 | Above200-250 | Rmtr | 691.13 | 691.13 | 50.0 | False | None | None | False | None | False | 34556.5 | 0 | 3876741 | 148756 | None | CSR 2022 Vol-V, It. No.O020F Pg No.151 | Above 300-350 | Rmtr | 894.04 | 894.04 | 50.0 | False | None | None | False | None | False | 44702.0 | 0 |
| 1724915185000 | 0 | None | None | Buildings | Construction of police station Grade-4 at Jayanagar in Tumkur district Compound wall | 1478438.28 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3876742 | 148757 | None | vol 1 item 1.3 | Earth work excavation for foundation of structures upto 3 mtrs.by mechanical means as per drawing and technical specification,including setting out, providing shoring, strutting and bracing, removalof stumps and other deleterious matter, dressing of sides and bottom,filling back the excavated earth to the extent required and utilising /transporting the remaining earth upto 1.00km lead. including cost oflabour, materials and HOM etc., complete. | Cum | 195.3 | 195.3 | 58.78 | False | None | None | False | None | False | 11479.734 | 0 | 3876743 | 148757 | None | vol 1 item 1.4 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including | Cum | 208.95 | 208.95 | 26.0 | False | None | None | False | None | False | 5432.7 | 0 | 3876744 | 148757 | None | vol 2.1tem 2.1.3 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 15.0 | False | None | None | False | None | False | 89208.0 | 0 | 3876745 | 148757 | None | vol 1 item 2.2 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately ) | Cum | 6542.55 | 6542.55 | 12.0 | False | None | None | False | None | False | 78510.6 | 0 | 3876746 | 148757 | None | vol II item 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks
of size 400x200x200mm having block density more than 1800kg/m3
and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005
including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. | Cum | 1375.5 | 1375.5 | 248.0 | False | None | None | False | None | False | 341124.0 | 0 | 3876747 | 148757 | None | 2.2 | roviding and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications cooping m10 | Cum | 6288.45 | 6288.45 | 4.0 | False | None | None | False | None | False | 25153.8 | 0 | 3876748 | 148757 | None | vol 1 item 1.10 | Refilling available earth around trenches/pipelines, cables in layers not
exceeding 20 cms in depth, compacting each deposited layer by ramming after
watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour
complete as per specifications | Cum | 168.0 | 168.0 | 68.0 | False | None | None | False | None | False | 11424.0 | 0 | 3876749 | 148757 | None | vol 1 item 2.2 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. (The cost of steel reinforcement to be paid separately ) For columns | Cum | 6652.8 | 6652.8 | 21.66 | False | None | None | False | None | False | 144099.648 | 0 | 3876750 | 148757 | None | vol 1 iem 1.1 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations
and other similar works etc. in layers not exceeding 20cm in depth, consolidating
each deposited layer by ramming and watering, lead up to 50 m and lift upto
1.5 m new earth | Cum | 423.16 | 423.16 | 138.6 | False | None | None | False | None | False | 58649.976 | 0 | 3876751 | 148757 | None | vol 2 iem 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to
brick/stone masonry including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost of
materials, labour, curing complete as per specifications and as per directions of Engineer | Sqm | 404.25 | 404.25 | 722.0 | False | None | None | False | None | False | 291868.5 | 0 | 3876752 | 148757 | None | vol 2 item 8.35.1 | Painting with Silicon & Acrylic emulsion based water thinnable sealer of
approved brand and manufacture on wet or patchy portion of plastered
surfaces :One coat with paint of approved quality to give an even shade,
after thoroughly brooming the surface to remove all dirt, dust, mortar
drops and foreign matter including preparing the surface even and sand
paper smooth, cost of materials, labour complete as per specifications and
as per directions of Engineer-in-charge. | Cum | 107.1 | 107.1 | 722.0 | False | None | None | False | None | False | 77326.2 | 0 | 3876753 | 148757 | None | vol 2 page 15 iem 4.21 | Providing Patti around doors,windows,ventilators and for parapet and compound wall etc.,with cement mortar 1:3 and finished as per design and specification including scaffolding etc., complete as per directed by the engineer in charge of work. | m | 34.65 | 34.65 | 660.0 | False | None | None | False | None | False | 22869.0 | 0 | 3876754 | 148757 | None | vol II 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to steel windows by welding | Kg | 192.15 | 192.15 | 450.0 | False | None | None | False | None | False | 86467.5 | 0 | 3876755 | 148757 | None | VOL 1 2.11 ITEAM | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification. | Tonne | 93929.85 | 93929.85 | 2.5 | False | None | None | False | None | False | 234824.625 | 0 |
| 1724915185000 | 0 | None | None | Buildings | Construction of police station Grade-4 at Jayanagar in Tumkur district road | 350450.97 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3876756 | 148758 | None | PAGE 1.1 VOL 1 | Earth work in surface excavation for stripping, seating of bund, Road way, by
manual means for lowering & leveling the ground for all works other than
foundation & depth in all kinds of soil not exceeding 300mm as per drawing and
technical specifications, including setting out, shoring, strutting, barricading,
caution lights, removal of stumps and other deleterious matter including
dressing of excavated surfaces, disposing off or levelling the excavated earth or
sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto
1.5 m including cost of labour, tools, usage & other appurtenances required to
complete the wor | Cum | 64.05 | 64.05 | 45.0 | False | None | None | False | None | False | 2882.25 | 0 | 3876757 | 148758 | None | ITEM 2.1 VOL-1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. | Cum | 6222.3 | 6222.3 | 20.25 | False | None | None | False | None | False | 126001.575 | 0 | 3876758 | 148758 | None | 2.5 VOLUME 1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications | Cum | 6542.55 | 6542.55 | 20.25 | False | None | None | False | None | False | 132486.6375 | 0 | 3876759 | 148758 | None | page 6.32 item | Construction of cement concrete kerb with top and bottom
width 115 and 165 mm respectively, 250 mm high in M 15
grade foundation 150 mm thick, foundation having 50 mm
projection beyond kerb stone, kerb stone laid with kerb laying
machine, foundation concrete laid manually, all complete as
per clause 409 | Nos | 444.15 | 444.15 | 150.0 | False | None | None | False | None | False | 66622.5 | 0 | 3876760 | 148758 | None | item 8.11 page 66 | Providing and applying two coats of ready mix paint of approved
brand on steel surface after thorough cleaning of surface to give
an even shade New wood serface | Sqm | 95.0 | 95.0 | 120.0 | False | None | None | False | None | False | 11400.0 | 0 | 3876761 | 148758 | None | vol 2 8.10 item page 66 | Painting two coats after filling the surface with synthetic
enamel paint in all shades on new plastered concrete surfaces | Sqm | 92.15 | 92.15 | 120.0 | False | None | None | False | None | False | 11058.0 | 0 |
| 1724915185000 | 0 | None | None | Buildings | Construction of police station Grade-4 at Jayanagar in Tumkur district furniture | 396768.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3876762 | 148759 | None | NSR 1 | L Shape Table: Providing and fixing L Shape Table, table top made up of 25mm thick ply with post laminated MS powder coated alpha leg under structure with supporing metal modesty inclusive of standard pedestal. The drawers shall be mounted on telescopic slides fitted with brushed finish SS handels withall lead, lifts, loading, unloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and as per the directions of the Engineer in-charge of the work, Size 1800x900x750mm ht and 900x600x750mm ht. | Nos | 30656.0 | 30656.0 | 3.0 | False | None | None | False | None | False | 91968.0 | 0 | 3876763 | 148759 | None | NSR 2 | Executive chair: Providng & installing revolving type Executive chair with height adj, synchro tilt mechanism with 5 position lock system, mesh back for free air supply with good lumber suport, adj arms, nylon base with unbreakable twin wheel castors model: crown. with all lead, lifts, loading, unloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work. | Nos | 22193.0 | 22193.0 | 3.0 | False | None | None | False | None | False | 66579.0 | 0 | 3876764 | 148759 | None | NSR 3 | Visitor chair: Providng & installing Fixed type Visitor chair with mesh back for free air supply, MS powder coated tubluar under structure, model comfort vistor. with all lead, lifts, loading, unloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work. | Nos | 4143.0 | 4143.0 | 12.0 | False | None | None | False | None | False | 49716.0 | 0 | 3876765 | 148759 | None | NSR 4 | Work station : Providng & installing Table top made up of 25mm thick PLPB with approved laminate color with matching edge banding profile, vertical support to be 75mm thick partitions below table top laminate tiles, above table top one marker/one pin up board for each W/S, Inclusive of standard pedestal with all lead, lifts, loading, unloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work. 1200x600x1200 | Nos | 18495.0 | 18495.0 | 4.0 | False | None | None | False | None | False | 73980.0 | 0 | 3876766 | 148759 | None | NSR 5 | Executive chair: Providng & installing Revoiving type Executive chair with height adj, synchro tilt mechanism with single position lock system, mesh back for free air supply, adj arms, nylon base with unbreakale twin wheel castors model: comfor MBK. with all lead, lifts, loading, unloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work. | Nos | 5030.0 | 5030.0 | 6.0 | False | None | None | False | None | False | 30180.0 | 0 | 3876767 | 148759 | None | NSR 6 | Providng & installing Metal Tandem chair three seater. with all lead, lifts, loading, unloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work. | Nos | 6660.0 | 6660.0 | 3.0 | False | None | None | False | None | False | 19980.0 | 0 | 3876768 | 148759 | None | NSR 7 | Providng installing Free standing table made up of 25 mm thick ply post laminated with approved laminate shade with matching edge banding profile, with supporting gable ends with supporting modesty, table size in mm 1200x900x750ht . with all lead, lifts, loadingunloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer incharge of the work. | Nos. | 16127.0 | 16127.0 | 3.0 | False | None | None | False | None | False | 48381.0 | 0 | 3876769 | 148759 | None | NSR 9 | Providng & installing Plastic chairs for auditorium with all lead, lifts, loading, unloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work. | Nos. | 1332.0 | 1332.0 | 12.0 | False | None | None | False | None | False | 15984.0 | 0 |
| 1724915185000 | 0 | None | None | Buildings | Electrical estimate for Construction of police station Grade-4 at Jayanagar in Tumkur district | 1384049.7 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3876770 | 148760 | None | 1.2.1 | Electrical - Concealed Conduit System Supplying heavy gauge PVC conduit pipe …19/20…mm dia .2.mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary,as per the directions of Engineer in charge of the work. 1) 19/20mm dia 2mm thick
| Mtr | 66.0 | 66.0 | 500.0 | False | None | None | False | None | False | 33000.0 | 0 | 3876771 | 148760 | None | 1.2.2 | Concealed Conduit System - Supplying heavy gauge PVC conduit pipe …25…mm dia .2.mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary and as per the directions of Engineer in charge of the work. 2) 25mm dia 2mm thick
| Mtr | 78.0 | 78.0 | 400.0 | False | None | None | False | None | False | 31200.0 | 0 | 3876772 | 148760 | None | 1.12 | Supplying and Fixing Metal Fan Box with Round Hook. and as per the directions of Engineer in charge of the work.
| Each | 160.0 | 160.0 | 20.0 | False | None | None | False | None | False | 3200.0 | 0 | 3876773 | 148760 | None | 1.3.1 | Groove cutting Supplying heavy gauge PVC Conduit Pipe 19/20….dia .2.mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary ,as per the directions of Engineer in charge of the work. 1) 19/20mm dia 2mm thick
| Mtr | 68.0 | 68.0 | 280.0 | False | None | None | False | None | False | 19040.0 | 0 | 3876774 | 148760 | None | 1.3.2 | Groove cutting Supplying heavy gauge PVC Conduit Pipe 25.dia .2.mm thick with suitable size bends, metal junction boxes adhesive
paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary ,as per the directions of Engineer in charge of the work. 1) 25mm dia 2mm thick
| Mtr | 79.0 | 79.0 | 150.0 | False | None | None | False | None | False | 11850.0 | 0 | 3876775 | 148760 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLSH PVC insulated 1100V grade 1.5 Sqmm
| Mtr | 26.0 | 26.0 | 650.0 | False | None | None | False | None | False | 16900.0 | 0 | 3876776 | 148760 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLSH PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments ,as per the directions of Engineer in charge of the work. 2) 2.5 Sqmm
| Mtr | 42.0 | 42.0 | 1200.0 | False | None | None | False | None | False | 50400.0 | 0 | 3876777 | 148760 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLSH PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments ,as per the directions of Engineer in charge of the work. 3) 4 Sqmm
| Mtr | 63.0 | 63.0 | 400.0 | False | None | None | False | None | False | 25200.0 | 0 | 3876778 | 148760 | None | 2.2.1 | Point wiring using copper wire with out switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSH multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. as per the directions of Engineer in charge of the work. 1) Short point upto 3Mtr. from tapping point to out let via switch.
| Point | 269.0 | 269.0 | 20.0 | False | None | None | False | None | False | 5380.0 | 0 | 3876779 | 148760 | None | 2.2.2 | Point wiring using copper wire with out switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSH multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. as per the directions of Engineer in charge of the work. 2) Medium point above 3Mtr. Upto 6Mtr. from tapping point to out let via switch
| Point | 379.0 | 379.0 | 62.0 | False | None | None | False | None | False | 23498.0 | 0 | 3876780 | 148760 | None | 2.2.3 | Point wiring using copper wire with out switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSH multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. as per the directions of Engineer in charge of the work. c) Long point above 6Mtr. Upto 10Mtr. from tapping point to out let via switch.
| Point | 555.0 | 555.0 | 20.0 | False | None | None | False | None | False | 11100.0 | 0 | 3876781 | 148760 | None | Ele SR 14-15 Item No-4.2.2 | Supplying and fixing PBBC/bakelite straight or slant batten holder and wiring, within 60w/230 Volts lamps.
| No | 71.0 | 71.0 | 50.0 | False | None | None | False | None | False | 3550.0 | 0 | 3876782 | 148760 | None | Ele SR 14-15 Item No-4.4 | Suppying and fixing cast Aluminium round or ablong type LED 10 watts bulk head fitting suitable for operation of 220 to 240 Volts with burning hours 25 to 50,000 ,as per the directions of Engineer in charge of the work.
| Each | 952.0 | 952.0 | 4.0 | False | None | None | False | None | False | 3808.0 | 0 | 3876783 | 148760 | None | 6.3.1 | 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,
50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48"" Sweep (1200mm). and as per the directions of Engineer in charge of the work. Rated air delivery 210 +/- 10% CMM(Cubic Meters per Minute)
| Each | 2984.0 | 2984.0 | 20.0 | False | None | None | False | None | False | 59680.0 | 0 | 3876784 | 148760 | None | 13.10 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring ,as per the directions of Engineer in charge of the work.
| Each | 171.0 | 171.0 | 20.0 | False | None | None | False | None | False | 3420.0 | 0 | 3876785 | 148760 | None | 6.1 | Supplying exhaust fan of 1440 RPM of 300 mm(12') size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply, ,as per directions of engineer incharge of the work.
| Each | 1492.0 | 1492.0 | 8.0 | False | None | None | False | None | False | 11936.0 | 0 | 3876786 | 148760 | None | 13.14 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. Ceiling rose wisth sufficient length of 23/0.0076 inch PVC insulated twincore wire ,as per directions of engineer incharge of the work.
| Each | 707.0 | 707.0 | 8.0 | False | None | None | False | None | False | 5656.0 | 0 | 3876787 | 148760 | None | 11.3.2 | Supplying of .feet -PVC Batten with integrated LED tube .
LED light fitting 1 x 4' - 20/22 W
| Each | 690.0 | 690.0 | 15.0 | False | None | None | False | None | False | 10350.0 | 0 | 3876788 | 148760 | None | 11.3.3 | Supplying of LED ENERGY SAVING slim type 4' feet light fitting of 28 watts Bright LED light | No | 1197.0 | 1197.0 | 25.0 | False | None | None | False | None | False | 29925.0 | 0 | 3876789 | 148760 | None | 13.7.1 | Fixing all types and all capacities of LED light fittings indoor on the wall / ceiling /
rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks , holder with adopter and clamps. a) On wall/ceiling/Rafter/Girders ,as per the directions of Engineer in charge of the work.
| No | 122.0 | 122.0 | 40.0 | False | None | None | False | None | False | 4880.0 | 0 | 3876790 | 148760 | None | 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to
complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia as per the directions of Engineer in charge of the work.
| Set | 3510.0 | 3510.0 | 2.0 | False | None | None | False | None | False | 7020.0 | 0 | 3876791 | 148760 | None | 12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts ,as per directions of engineer incharge of the work.
| Each | 4256.0 | 4256.0 | 2.0 | False | None | None | False | None | False | 8512.0 | 0 | 3876792 | 148760 | None | Ele SR 2019-20 6.3.1 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required ,as per directions of engineer incharge of the work. GI strip 25x3mm
| Mtr | 75.0 | 75.0 | 20.0 | False | None | None | False | None | False | 1500.0 | 0 | 3876793 | 148760 | None | 12.58.7 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. copper strip 25x3mm
| Each | 570.0 | 570.0 | 25.0 | False | None | None | False | None | False | 14250.0 | 0 | 3876794 | 148760 | None | 12.58.11 | Supplying and running of Copper strips for grounding connections, using necessary fixing materials as required. Copper strip f) 600 x 600 x 3mm copper plate as per the directions of Engineer in charge of the work.
| Each | 7421.0 | 7421.0 | 2.0 | False | None | None | False | None | False | 14842.0 | 0 | 3876795 | 148760 | None | 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting
in Brick/Stone/C.C wall ,as per the directions of Engineer in charge of the work. i) 1-3Way
| Each | 159.0 | 159.0 | 35.0 | False | None | None | False | None | False | 5565.0 | 0 | 3876796 | 148760 | None | 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,as per the directions of Engineer in charge of the work. ii) 4-5Way
| Each | 177.0 | 177.0 | 25.0 | False | None | None | False | None | False | 4425.0 | 0 | 3876797 | 148760 | None | 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,as per the directions of Engineer in charge of the work. ii) 6Way
| Each | 220.0 | 220.0 | 25.0 | False | None | None | False | None | False | 5500.0 | 0 | 3876798 | 148760 | None | 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,as per the directions of Engineer in charge of the work. iii) 8Way
| Each | 261.0 | 261.0 | 35.0 | False | None | None | False | None | False | 9135.0 | 0 | 3876799 | 148760 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,as per the directions of Engineer in charge of the work. iii) 10-12 Way
| Each | 319.0 | 319.0 | 8.0 | False | None | None | False | None | False | 2552.0 | 0 | 3876800 | 148760 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box ,as per the directions of Engineer in charge of the work. i)1 to 3 Module
| Each | 161.0 | 161.0 | 35.0 | False | None | None | False | None | False | 5635.0 | 0 | 3876801 | 148760 | None | 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. and as per the directions of Engineer in charge of the work. ii) 4 Module
| Each | 175.0 | 175.0 | 25.0 | False | None | None | False | None | False | 4375.0 | 0 | 3876802 | 148760 | None | 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. and as per the directions of Engineer in charge of the work. iii) 6 Module
| Each | 234.0 | 234.0 | 25.0 | False | None | None | False | None | False | 5850.0 | 0 | 3876803 | 148760 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. and as per the directions of Engineer in charge of the work. iv) 8 Module
| Each | 284.0 | 284.0 | 35.0 | False | None | None | False | None | False | 9940.0 | 0 | 3876804 | 148760 | None | 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. and as per the directions of Engineer in charge of the work. iv) 10-12 Module
| Each | 344.0 | 344.0 | 6.0 | False | None | None | False | None | False | 2064.0 | 0 | 3876805 | 148760 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. i) 6 Amps one way switch
| Each | 102.0 | 102.0 | 140.0 | False | None | None | False | None | False | 14280.0 | 0 | 3876806 | 148760 | None | 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. iv) b) 16 Amps one way switch
| Each | 180.0 | 180.0 | 20.0 | False | None | None | False | None | False | 3600.0 | 0 | 3876807 | 148760 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. ii) 6 Amps 3 way socket
| Each | 171.0 | 171.0 | 70.0 | False | None | None | False | None | False | 11970.0 | 0 | 3876808 | 148760 | None | 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. iv) d) 6/16 Amps universal socket
| Each | 236.0 | 236.0 | 5.0 | False | None | None | False | None | False | 1180.0 | 0 | 3876809 | 148760 | None | 8.10.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. l) RJ45/I.O. outlet
| Each | 550.0 | 550.0 | 34.0 | False | None | None | False | None | False | 18700.0 | 0 | 3876810 | 148760 | None | 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. v) Stepped Fan Regulator
| Each | 313.0 | 313.0 | 20.0 | False | None | None | False | None | False | 6260.0 | 0 | 3876811 | 148760 | None | 3.6.12 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. and as per the directions of Engineer in charge of the work. vi) TV socket
| Each | 147.0 | 147.0 | 2.0 | False | None | None | False | None | False | 294.0 | 0 | 3876812 | 148760 | None | 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. 32Amps DP switch
| Each | 375.0 | 375.0 | 5.0 | False | None | None | False | None | False | 1875.0 | 0 | 3876813 | 148760 | None | 12.2.3 | Supplyingandfixingoneof230VDingdongbellandaflushtypebellpushwithgangboxfixedonnecessarywoodenorrawlplugsusingNFscrews with Remote.
| Each | 1190.0 | 1190.0 | 4.0 | False | None | None | False | None | False | 4760.0 | 0 | 3876814 | 148760 | None | Bescom SR 21-22 32.07 | Supplying of 1.1 kV, XLPE or Heat resistant PVC
insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 a) 3.5 core 25 sqmm
| Mtr | 181.45 | 181.45 | 120.0 | False | None | None | False | None | False | 21774.0 | 0 | 3876815 | 148760 | None | Bescom SR 21-22 32.05 | Supplying of 1.1 kV, XLPE or Heat resistant PVC
insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 a) 4 core 16 sqmm
| Mtr | 183.44 | 183.44 | 80.0 | False | None | None | False | None | False | 14675.2 | 0 | 3876816 | 148760 | None | Bescom SR 21-22 31.06 | Labour charges for Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff a) 25 sqmm to 75 sqmm
| Mtr | 23.64 | 23.64 | 120.0 | False | None | None | False | None | False | 2836.8 | 0 | 3876817 | 148760 | None | Bescom SR 21-22 31.05 | Labour charges for laying of 1.1 KV class UG cable when supplied agency stoneware pipe / on wall / on pole as required. In exixting trench/duct. 2.5 sqmm to 25 sqmm as per the directions of Engineer in charge of the work.
| Mtr | 20.88 | 20.88 | 80.0 | False | None | None | False | None | False | 1670.4 | 0 | 3876818 | 148760 | None | Ele SR 2019-20 6.10.3 | Supplying and fixing L.T. cast Iron pot heads suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps, bolts, nuts and
washers etc. 1) 25 Sqmm
| Each | 350.0 | 350.0 | 2.0 | False | None | None | False | None | False | 700.0 | 0 | 3876819 | 148760 | None | Ele SR 2019-20 6.6.1 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) as per the directions of Engineer in charge of the work.
| Mtr | 76.0 | 76.0 | 75.0 | False | None | None | False | None | False | 5700.0 | 0 | 3876820 | 148760 | None | Ele SR 2019-20 6.9.1 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class. and as per the directions of Engineer in charge of the work. 1) 40 mm
| Mtr | 335.0 | 335.0 | 10.0 | False | None | None | False | None | False | 3350.0 | 0 | 3876821 | 148760 | None | Ele SR 2019-20 .7.20.3 | Supplying and Laying double walled corrugated HDPE Pipe in clouding all accessories
| Mtr | 215.0 | 215.0 | 50.0 | False | None | None | False | None | False | 10750.0 | 0 | 3876822 | 148760 | None | 5.42.2 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with suitable approved colour powder coated paint ,as per directions of engineer incharge of the work. 1) 16 SWG
| Sq CM | 0.43 | 0.43 | 65000.0 | False | None | None | False | None | False | 27950.0 | 0 | 3876823 | 148760 | None | 5.41.2 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint ,as per directions of engineer incharge of the work.
b) 40x40x6mm
| Mtr | 305.0 | 305.0 | 8.0 | False | None | None | False | None | False | 2440.0 | 0 | 3876824 | 148760 | None | 5.40.2 | supplying .250. amps rated 3phase with neutral bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers ,as per directions of engineer incharge of the work.
a) 250 Amps 4x30x10mm Aluminium Strips
| Mtr | 3435.0 | 3435.0 | 0.5 | False | None | None | False | None | False | 1717.5 | 0 | 3876825 | 148760 | None | 5.11.2 | Supplying of on load change over over switches 4 poles, AC 23Amps duty 415V, 50HZ, AC Supply ,as per directions of engineer incharge of the work.
100Amps
| Each | 7090.0 | 7090.0 | 1.0 | False | None | None | False | None | False | 7090.0 | 0 | 3876826 | 148760 | None | 5.15.10 | Supplying and Fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete, protection of Overload and Short circuit with thermal Magnetic/Microprocessed release and Earth Fault as per IS-13947. (icu =lcs)
FOUR POLE) ,as per directions of engineer incharge of the work.
a)125 Amps 25kA
| Each | 10341.0 | 10341.0 | 1.0 | False | None | None | False | None | False | 10341.0 | 0 | 3876827 | 148760 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C 50Hz 12/24v D.C ,as per the directions of Engineer in charge of the work.
| Each | 515.0 | 515.0 | 3.0 | False | None | None | False | None | False | 1545.0 | 0 | 3876828 | 148760 | None | 5.29 | Supplying, fixing and wiring 3 phase Digital Ammeter/ Voltmeter ,as per directions of engineer incharge of the work.
| Each | 1425.0 | 1425.0 | 2.0 | False | None | None | False | None | False | 2850.0 | 0 | 3876829 | 148760 | None | 5.17.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 ,as per the directions of Engineer in charge of the work. 6-32Amps SP
| No | 523.0 | 523.0 | 12.0 | False | None | None | False | None | False | 6276.0 | 0 | 3876830 | 148760 | None | 5.17.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 ,as per the directions of Engineer in charge of the work. 6-32Amps DP
| Each | 1103.0 | 1103.0 | 3.0 | False | None | None | False | None | False | 3309.0 | 0 | 3876831 | 148760 | None | 5.17.7 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 ,as per the directions of Engineer in charge of the work. 6-32Amps TPN
| Each | 1777.0 | 1777.0 | 5.0 | False | None | None | False | None | False | 8885.0 | 0 | 3876832 | 148760 | None | 5.18.9 | SSupplying and fixing regular Double Door 12 Way SP &N MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. 1) Double Door 12 Way SP &N and as per the directions of Engineer in charge of the work
| Each | 2329.0 | 2329.0 | 4.0 | False | None | None | False | None | False | 9316.0 | 0 | 3876833 | 148760 | None | 5.20.1 | Supplying, fixing and wiring Residual current circuit breaker (RCCB)
240/450V upto 300mA sensitivity on existing wood/ panel board.
16-25 Amps 2 pole and as per the directions of Engineer in charge of the work.
| Each | 4277.0 | 4277.0 | 4.0 | False | None | None | False | None | False | 17108.0 | 0 | 3876834 | 148760 | None | 11.8.3 | Supply of LED Streetlight 70w luminaire with pressure die cast
| Each | 5992.0 | 5992.0 | 4.0 | False | None | None | False | None | False | 23968.0 | 0 | 3876835 | 148760 | None | 13.1.2 | Supplying and Fixing of …….mm dia class A GI pipe bracket up to 2 mtrs long bent at suitable angle and fixing to this bracket 1 x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CL or rail or RCC pole/wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires Using 32mm dia G.I.Pipe, ,as per directions of engineer incharge of the work.
| Each | 978.0 | 978.0 | 4.0 | False | None | None | False | None | False | 3912.0 | 0 | 3876836 | 148760 | None | 11.6.3 | Supplying of recess mounting non integral type .2'x2' 36watt LED modular down light 2'x2' 36watt
| Each | 4553.0 | 4553.0 | 2.0 | False | None | None | False | None | False | 9106.0 | 0 | 3876837 | 148760 | None | 11.11.7 | Supplying & fixing of retrofit type - LED bulb 18 W 18W, 6500K
| No | 154.0 | 154.0 | 20.0 | False | None | None | False | None | False | 3080.0 | 0 | 3876838 | 148760 | None | 8.1 | Supply& Laying of UTP cat-6E LAN cable and as per the directions of Engineer in charge of the work.
| Mtr | 38.0 | 38.0 | 2000.0 | False | None | None | False | None | False | 76000.0 | 0 | 3876839 | 148760 | None | 8.2.2 | Supplying and drawing PVC flexible one pair telepone unarmoured tinned copper cable. 2 pair and as per the directions of Engineer in charge of the work.
| Mtr | 19.0 | 19.0 | 120.0 | False | None | None | False | None | False | 2280.0 | 0 | 3876840 | 148760 | None | 8.4.2 | Supplying & Fixing of switch mounting rack with power manager & Cable manager. 6U with 450mm depth
| Each | 4657.0 | 4657.0 | 3.0 | False | None | None | False | None | False | 13971.0 | 0 | 3876841 | 148760 | None | 8.9.6 | Supplying fixing of Network Switches. 16 port Switch and as per the directions of Engineer in charge of the work.
| No | 2809.0 | 2809.0 | 2.0 | False | None | None | False | None | False | 5618.0 | 0 | 3876842 | 148760 | None | 8.9.2 | Supplying fixing of Network Switches. port24 Port Gigabyte (manageable) and as per the directions of Engineer in charge of the work.
| No | 46053.0 | 46053.0 | 1.0 | False | None | None | False | None | False | 46053.0 | 0 | 3876843 | 148760 | None | 8.12.2 | Supplying & Fixing of Patch panel for LAN cabling 24 port 10/100 patch panel and as per the directions of Engineer in charge of the work.
| No | 4258.0 | 4258.0 | 2.0 | False | None | None | False | None | False | 8516.0 | 0 | 3876844 | 148760 | None | 8.12.3 | Supplying & Fixing of Patch panel for LAN cabling 16 Port 10/100 patch panel and as per the directions of Engineer in charge of the work.
| No | 3050.0 | 3050.0 | 1.0 | False | None | None | False | None | False | 3050.0 | 0 | 3876845 | 148760 | None | 8.10.2 | Supplying & fixing of I/O socket with back box, Double I/o
| Each | 727.0 | 727.0 | 34.0 | False | None | None | False | None | False | 24718.0 | 0 | 3876846 | 148760 | None | 8.11.1 | Supplying & fixing of 1 mtrs. Cat 6Patch Cable. 2Mtr
| Each | 224.0 | 224.0 | 34.0 | False | None | None | False | None | False | 7616.0 | 0 | 3876847 | 148760 | None | 8.11.2 | Supplying & fixing of 2 mtrs. Cat 6Patch Cable. 2Mtr
| Each | 257.0 | 257.0 | 34.0 | False | None | None | False | None | False | 8738.0 | 0 | 3876848 | 148760 | None | 15.5 | Supplyandinstallationo f 9kgStoredPressureType,PressureGuage,GrossWeight14.9Kg,emptyweight3.4Kg,CanHeight480MM,Diameter160MM,DischargeTimelessthan13Sees,Controllabledischargemechanism(Squeezegripwitheasysnapsafetyseal),Rangeminimum4meters,CanconstructionDeepdrawn&Co.,Migwelded,valveConstrucitonForgingandMechining,InternalCoatingofCan:Epoxypowdercoating,ExternalCoatingofCan:EpoxyPolysterpowercoating,Sheetmetalthickness:1.60MM,IS15683andCEApproved5yearswarranty.withinstalertsystemwithSuperiorqualityEPDMRubberHosepipeetc.,includingcostcostofsupportingmaterialslikeMSstand&accessariesifitisfixingnfloor/MSbrackets&accessoriesifitisfixingonwall,labour,usagechargesofmachinerycompleteasperspecifications. completes. complete and as per the directions of Engineer in charge of the work.
| Set | 3350.0 | 3350.0 | 2.0 | False | None | None | False | None | False | 6700.0 | 0 | 3876849 | 148760 | None | Civil SR | Supplying of 1 HP Open well Mono sub pump set suitable for operation on 230 volts 2880 RPM single phase AC supply And as per the directions of engineer incharge of the work.
| Set | 9138.0 | 9138.0 | 1.0 | False | None | None | False | None | False | 9138.0 | 0 | 3876850 | 148760 | None | NSR | Supplying of 50 mm kirloskar / other approved make CI screwed foot valve, as per the directions of engineer incharge of the work.
| No | 450.0 | 450.0 | 1.0 | False | None | None | False | None | False | 450.0 | 0 | 3876851 | 148760 | None | 5.1 | Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP.
| Each | 1490.0 | 1490.0 | 1.0 | False | None | None | False | None | False | 1490.0 | 0 | 3876852 | 148760 | None | Civil SR 21-22 pg No 13.6 P130F | Providing, supplying to work site, Submersible Pump Set 5 HP 15 stage of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl
& Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work.
| Set | 35950.0 | 35950.0 | 1.0 | False | None | None | False | None | False | 35950.0 | 0 | 3876853 | 148760 | None | NSR | Erection, Electrification and commissioning Work of Pump Sets : eraction of pumpset including aligning and balancing with all necessary erection materials and labour including supply and erection of two pair of supporting clamps, bore-well, cap, cable ,as per the directions of Engineer in charge of the work.
| Set | 5000.0 | 5000.0 | 1.0 | False | None | None | False | None | False | 5000.0 | 0 | 3876854 | 148760 | None | Civil SR 18-19 Sl No. 13.37 | KSRB 13-6.3-: Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) NB including cost of all materials, labour and HOM of equipments with all leads complete as per specifications ,as per the directions of Engineer in charge of the work.
| Each | 1739.0 | 1739.0 | 1.0 | False | None | None | False | None | False | 1739.0 | 0 | 3876855 | 148760 | None | Civil SR 18-19 Sl No. 13.62 | KSRB13-7.2: Providing and fixing in position 50 mm nominal bore non-return valve vertical type of approved make including cost of all materials, labour and HOM of equipments with alll leads complete as per specifications ,as per the directions of Engineer in charge of the work.
| Each | 1269.0 | 1269.0 | 1.0 | False | None | None | False | None | False | 1269.0 | 0 | 3876856 | 148760 | None | Civil SR 21-22 P280A | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter for outdoor
Upto 6 HP pumps
| Set | 12500.0 | 12500.0 | 1.0 | False | None | None | False | None | False | 12500.0 | 0 | 3876857 | 148760 | None | 2.6.2 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts as per IS-694:1990. 3C X 4.0Sq.mm as per the directions of the engineer in charge of the work.
| Rmtr | 168.0 | 168.0 | 250.0 | False | None | None | False | None | False | 42000.0 | 0 | 3876858 | 148760 | None | Civil SR 2018-19 | Providing and fixing in trenches galvanised/ mildsteel tubes 50mm dia nominal bore with all fittings including cost of all materials and labour charges and HOM of equipments and testing complete as per specifications
Make - Group ""A"" materials and as per the directions of Engineer in charge of the work.
| Mtr | 512.0 | 512.0 | 200.0 | False | None | None | False | None | False | 102400.0 | 0 | 3876859 | 148760 | None | 5.7.3 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 63Amps and as per the directions of Engineer in charge of the work.
| No | 401.0 | 401.0 | 6.0 | False | None | None | False | None | False | 2406.0 | 0 | 3876860 | 148760 | None | Bescom SR 2023-224 1.01 | Supplying 9 Mtr RCC Pole 145Kg WL. including earth work etc,. Complete as per the standard technical specification., 9 Mtr 145Kg WL. (Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785 ,as per the directions of Engineer in charge of the work.
| Each | 7076.0 | 7076.0 | 1.0 | False | None | None | False | None | False | 7076.0 | 0 | 3876861 | 148760 | None | Bescom SR 2023-24 2.05 | Supplying of L.T.4 Pin cross arms, with pole clamps, bolts, nuts and washers (for RCC poles)
| Set | 289.0 | 289.0 | 2.0 | False | None | None | False | None | False | 578.0 | 0 | 3876862 | 148760 | None | Bescom SR 2023-24 7.02 | Supplying of Rabbit ACSR Conductor with 1.5% sag.and as per the directions of Engineer in charge of the work.
| Km | 46234.0 | 46234.0 | 0.4 | False | None | None | False | None | False | 18493.6 | 0 | 3876863 | 148760 | None | Bescom SR18-19 | Fixing of guy set with guy wire, guyrod and break insulators etc complete set and as per the directions of Engineer in charge of the work.
| No | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 | 3876864 | 148760 | None | Bescom SR 2023-24 2.02 | Erection of RCC PSC poles 9 to 10 mtr long but in a pit of 1.8 mtr depth with consoldation etc, complete ,as per the directions of Engineer in charge of the work.
| No | 922.0 | 922.0 | 2.0 | False | None | None | False | None | False | 1844.0 | 0 | 3876865 | 148760 | None | Bescom SR 2023-24 5.02 | Fixing of 4 Pin cross arm with insulator and Braces fixing and as per the directions of Engineer in charge of the work.
| Set | 160.0 | 160.0 | 6.0 | False | None | None | False | None | False | 960.0 | 0 | 3876866 | 148760 | None | 9.3.3 | Supplying, erecting, testing & commissioning of 5 KVA ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories one hour back up complete and Excluding batteries and wiring complete. 5 KVA
| Set | 68383.0 | 68383.0 | 1.0 | False | None | None | False | None | False | 68383.0 | 0 | 3876867 | 148760 | None | 9.4.3 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 60 to 65 AH capacity
| Each | 6413.0 | 6413.0 | 12.0 | False | None | None | False | None | False | 76956.0 | 0 | 3876868 | 148760 | None | 11.7.1 | Supply of LED pole mounting type LED Post Top Lantern with 25 watts
| No | 6922.0 | 6922.0 | 2.0 | False | None | None | False | None | False | 13844.0 | 0 | 3876869 | 148760 | None | 13.6 | Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI / GI or any other pipe using required size of reducer, wiring using suitable wires
| Each | 198.0 | 198.0 | 2.0 | False | None | None | False | None | False | 396.0 | 0 | 3876870 | 148760 | None | CSR page 247 21.1. 1Vol 5 | Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components-For 25 LPH : Cabin Type
| No | 25000.0 | 25000.0 | 1.0 | False | None | None | False | None | False | 25000.0 | 0 | 3876871 | 148760 | None | Approved rates | Supply of erection testing and commissioning of water level controller and connected accessoriers etc.
| No | 10000.0 | 10000.0 | 1.0 | False | None | None | False | None | False | 10000.0 | 0 | 3876872 | 148760 | None | 2.5.4 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 6C x 1.5 mm2
| Mtr | 121.0 | 121.0 | 60.0 | False | None | None | False | None | False | 7260.0 | 0 | 3876873 | 148760 | None | Bescom SR 2023-24 5.17 | Stringing of No.1 ACSR Rabbit conductor with 1.5% sag and as per the directions of Engineer in charge of the work.
| Km | 5233.0 | 5233.0 | 0.4 | False | None | None | False | None | False | 2093.2 | 0 | 3876874 | 148760 | None | 6.22 | Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out
door/indoor A.C. unit/ Batteries.
| Each | 4807.0 | 4807.0 | 1.0 | False | None | None | False | None | False | 4807.0 | 0 |
|
|
---|