1725081417000 | 0 | None | None | Buildings | Construction of 02 Dormitory in existing First Floor, Dining Hall, New Pit, 03 Toilets, 03 Bath Rooms and Painting Work ETC at Post Metric Boys hostel, Kalale, Nanjanagudu Taluk 2274 (SC) | 1684471.33 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3891473 | 149611 | None | code01 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar (PWD CSR Vol-2 of 2023-24, Pg no-187, Si no-19.7.3) | Cum | 1029.0 | 1029.0 | 4.25 | False | None | None | False | None | False | 4373.25 | 0 | 3891474 | 149611 | None | code02 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (PWD CSR Vol-1 of 2023-24, Pg no-5, Si no-1.4.1) | Cum | 242.0 | 242.0 | 5.5 | False | None | None | False | None | False | 1331.0 | 0 | 3891475 | 149611 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (PWD CSR Vol-1 of 2023-24, Pg no-15, Si no-2.1.2) | Cum | 5664.0 | 5664.0 | 0.73 | False | None | None | False | None | False | 4134.72 | 0 | 3891476 | 149611 | None | code04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR Vol-1 of 2023-24, Pg no-15, Si no-2.2.1) | Cum | 6475.61 | 6475.61 | 1.01 | False | None | None | False | None | False | 6540.3661 | 0 | 3891477 | 149611 | None | code05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR Vol-1 of 2023-24, Pg no-16, Si no-2.5.1) Ground Floor | Cum | 11271.0 | 11271.0 | 0.71 | False | None | None | False | None | False | 8002.41 | 0 | 3891478 | 149611 | None | code06 | Stair Beams | Cum | 10608.0 | 10608.0 | 0.5 | False | None | None | False | None | False | 5304.0 | 0 | 3891479 | 149611 | None | code07 | Stair Case Waiste slab | Cum | 9945.0 | 9945.0 | 2.37 | False | None | None | False | None | False | 23569.65 | 0 | 3891480 | 149611 | None | code08 | First Floor | Cum | 11383.71 | 11383.71 | 3.32 | False | None | None | False | None | False | 37793.9172 | 0 | 3891481 | 149611 | None | code09 | Lintel | Cum | 10714.08 | 10714.08 | 1.63 | False | None | None | False | None | False | 17463.9504 | 0 | 3891482 | 149611 | None | code10 | Beams | Cum | 10714.08 | 10714.08 | 6.71 | False | None | None | False | None | False | 71891.4768 | 0 | 3891483 | 149611 | None | code11 | Roof Slab | Cum | 10044.45 | 10044.45 | 14.97 | False | None | None | False | None | False | 150365.4165 | 0 | 3891484 | 149611 | None | code12 | Stair Case | Cum | 10044.45 | 10044.45 | 2.33 | False | None | None | False | None | False | 23403.5685 | 0 | 3891485 | 149611 | None | code13 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR Vol-2 of 2023-24, Pg no-17, Si no-6.32) | Sqm | 1323.1 | 1323.1 | 140.74 | False | None | None | False | None | False | 186213.094 | 0 | 3891486 | 149611 | None | code14 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR Vol-1 of 2023-24, Pg no-16, Si no-2.5.1) | Cum | 9709.64 | 9709.64 | 0.52 | False | None | None | False | None | False | 5049.0128 | 0 | 3891487 | 149611 | None | code15 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms, c to c both horizontally and vertically fixed with chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specifications. (PWD CSR Vol-2 of 2023-24, Pg no-44, Si no-8.16a) Gr.Flr | Sqm | 1238.0 | 1238.0 | 14.24 | False | None | None | False | None | False | 17629.12 | 0 | 3891488 | 149611 | None | code16 | First Floor | Sqm | 1250.38 | 1250.38 | 16.54 | False | None | None | False | None | False | 20681.2852 | 0 | 3891489 | 149611 | None | code17 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (PWD CSR Vol-1 of 2023-24, Pg no-18, Si no-2.11a) | t | 89457.0 | 89457.0 | 0.415 | False | None | None | False | None | False | 37124.655 | 0 | 3891490 | 149611 | None | code18 | First Floor | t | 90351.57 | 90351.57 | 2.953 | False | None | None | False | None | False | 266808.18621 | 0 | 3891491 | 149611 | None | code19 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (PWD CSR Vol-2 of 2023-24, Pg no-104, Si no-12.51) | No | 1026.16 | 1026.16 | 2.0 | False | None | None | False | None | False | 2052.32 | 0 | 3891492 | 149611 | None | code20 | Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (PWD CSR Vol-2 of 2023-24, Pg no-104, Si no-12.52) | No | 780.73 | 780.73 | 6.0 | False | None | None | False | None | False | 4684.38 | 0 | 3891493 | 149611 | None | code21 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD CSR Vol-2 of 2023-24, Pg no-99, Si no-12.11) | Cum | 139454.74 | 139454.74 | 0.471 | False | None | None | False | None | False | 65683.18254 | 0 | 3891494 | 149611 | None | code22 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) (PWD CSR Vol-2 of 2023-24, Pg no-100, Si no-12.15) | Sqm | 7518.44 | 7518.44 | 4.2 | False | None | None | False | None | False | 31577.448 | 0 | 3891495 | 149611 | None | code23 | Providing and fixing in position fully panelled shutters of Honne wood for windows with stiles and rails of 30mm thick, 75mm wide in two halves with panels of 20mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) (PWD CSR Vol-2 of 2023-24, Pg no-101, Si no-12.27) | No | 6767.0 | 6767.0 | 10.8 | False | None | None | False | None | False | 73083.6 | 0 | 3891496 | 149611 | None | code24 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (PWD CSR Vol-2 of 2023-24, Pg no-86, Si no-11.34B) | Sqm | 184.83 | 184.83 | 656.71 | False | None | None | False | None | False | 121379.7093 | 0 | 3891497 | 149611 | None | code25 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (PWD CSR Vol-2 of 2023-24, Pg no-105, Si no-12.58) | No | 121.2 | 121.2 | 4.0 | False | None | None | False | None | False | 484.8 | 0 | 3891498 | 149611 | None | code26 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (PWD CSR Vol-2 of 2023-24, Pg no-105, Si no-12.60) | No | 1062.52 | 1062.52 | 2.0 | False | None | None | False | None | False | 2125.04 | 0 | 3891499 | 149611 | None | code27 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD CSR Vol-2 of 2023-24, Pg no-105, Si no-12.62) | No | 239.37 | 239.37 | 4.0 | False | None | None | False | None | False | 957.48 | 0 | 3891500 | 149611 | None | code28 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (PWD CSR Vol-2 of 2023-24, Pg no-105, Si no-12.63) | No | 131.3 | 131.3 | 44.0 | False | None | None | False | None | False | 5777.2 | 0 | 3891501 | 149611 | None | code29 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD CSR Vol-2 of 2023-24, Pg no-83, Si no-11.17) | No | 184.83 | 184.83 | 5.0 | False | None | None | False | None | False | 924.15 | 0 | 3891502 | 149611 | None | code30 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR Vol-2 of 2023-24, Pg no-43, Si no-8.10) | Sqm | 213.11 | 213.11 | 87.06 | False | None | None | False | None | False | 18553.3566 | 0 | 3891503 | 149611 | None | code31 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR Vol-2 of 2023-24, Pg no-42, Si no-8.5.2) | Sqm | 352.49 | 352.49 | 130.2 | False | None | None | False | None | False | 45894.198 | 0 | 3891504 | 149611 | None | code32 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR Vol-2 of 2023-24, Pg no-42, Si no-8.9) | Sqm | 385.0 | 385.0 | 45.58 | False | None | None | False | None | False | 17548.3 | 0 | 3891505 | 149611 | None | code33 | First Floor | Sqm | 388.85 | 388.85 | 278.28 | False | None | None | False | None | False | 108209.178 | 0 | 3891506 | 149611 | None | code34 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (PWD CSR Vol-2 of 2023-24, Pg no-61, Si no-9.17.2) | Sqm | 1186.75 | 1186.75 | 93.66 | False | None | None | False | None | False | 111151.005 | 0 | 3891507 | 149611 | None | code35 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete. (PWD CSR Vol-2 of 2023-24, Pg no-55, Si no-8.84) | Sqm | 479.75 | 479.75 | 21.75 | False | None | None | False | None | False | 10434.5625 | 0 | 3891508 | 149611 | None | code36 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. (PWD CSR Vol-2 of 2023-24, Pg no-59, Si no-9.1) | Sqm | 455.51 | 455.51 | 91.12 | False | None | None | False | None | False | 41506.0712 | 0 | 3891509 | 149611 | None | code37 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR Vol-2 of 2023-24, Pg no-45, Si no-8.28) | Sqm | 89.0 | 89.0 | 45.58 | False | None | None | False | None | False | 4056.62 | 0 | 3891510 | 149611 | None | code38 | 1st Floor | Sqm | 89.89 | 89.89 | 278.28 | False | None | None | False | None | False | 25014.5892 | 0 | 3891511 | 149611 | None | code39 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR Vol-2 of 2023-24, Pg no-45, Si no-8.25) | Sqm | 138.37 | 138.37 | 217.26 | False | None | None | False | None | False | 30062.2662 | 0 | 3891512 | 149611 | None | code40 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR Vol-2 of 2023-24, Pg no-47, Si no-8.33.3) | Sqm | 140.39 | 140.39 | 26.7 | False | None | None | False | None | False | 3748.413 | 0 | 3891513 | 149611 | None | code41 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR Vol-2 of 2023-24, Pg no-47, Si no-8.34.1) | Sqm | 53.33 | 53.33 | 39.0 | False | None | None | False | None | False | 2079.87 | 0 | 3891514 | 149611 | None | code42 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR Vol-2 of 2023-24, Pg no-46, Si no-8.33.2) | Sqm | 139.38 | 139.38 | 39.0 | False | None | None | False | None | False | 5435.82 | 0 | 3891515 | 149611 | None | code43 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks (PWD CSR Vol-2 of 2023-24, Pg no-123, Si no-13.36) | Each | 326.23 | 326.23 | 6.0 | False | None | None | False | None | False | 1957.38 | 0 | 3891516 | 149611 | None | code44 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10mm gap for thermal expansion (i) single socketes pipes 100mm diameter. (PWD CSR Vol-2 of 2023-24, Pg no-125, Si no-13.48) | Mtr | 293.91 | 293.91 | 20.7 | False | None | None | False | None | False | 6083.937 | 0 | 3891517 | 149611 | None | code45 | Concealed Conduit System Supplying heavy PVC condiuit pipe ……mm dia ......mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick (PWD Electrical CSR of 2023-2024, pg no-2 of 105, Si.no-1.2.2) | Mtr | 78.78 | 78.78 | 50.0 | False | None | None | False | None | False | 3939.0 | 0 | 3891518 | 149611 | None | code46 | Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25mm dia 2mm thick (PWD Electrical CSR of 2023-2024, pg no-2 of 105, Si.no-1.3.2) | Mtr | 79.79 | 79.79 | 40.0 | False | None | None | False | None | False | 3191.6 | 0 | 3891519 | 149611 | None | code47 | Supplying and fixing PVC/metal conduit accessories. deep junction box 25mm junction box (PWD Electrical CSR of 2023-2024, pg no-3 of 105, Si.no-1.5.2) | Each | 56.56 | 56.56 | 12.0 | False | None | None | False | None | False | 678.72 | 0 | 3891520 | 149611 | None | code48 | Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way (PWD Electrical CSR of 2023-2024, pg no-8 of 105, Si.no-3.4.4) | Each | 263.61 | 263.61 | 4.0 | False | None | None | False | None | False | 1054.44 | 0 | 3891521 | 149611 | None | code49 | Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way (PWD Electrical CSR of 2023-2024, pg no-8 of 105, Si.no-3.4.6) | Each | 322.19 | 322.19 | 4.0 | False | None | None | False | None | False | 1288.76 | 0 | 3891522 | 149611 | None | code50 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module (PWD Electrical CSR of 2023-2024, pg no-8 of 105, Si.no-3.5.5) | Each | 286.84 | 286.84 | 4.0 | False | None | None | False | None | False | 1147.36 | 0 | 3891523 | 149611 | None | code51 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10 - 12 Module (PWD Electrical CSR of 2023-2024, pg no-8 of 105, Si.no-3.5.6) | Each | 347.44 | 347.44 | 4.0 | False | None | None | False | None | False | 1389.76 | 0 | 3891524 | 149611 | None | code52 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch (PWD Electrical CSR of 2023-2024, pg no-9 of 105, Si.no-3.6.1) | Each | 103.02 | 103.02 | 14.0 | False | None | None | False | None | False | 1442.28 | 0 | 3891525 | 149611 | None | code53 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket. (PWD Electrical CSR of 2023-2024, pg no-9 of 105, Si.no-3.6.3) | Each | 172.71 | 172.71 | 14.0 | False | None | None | False | None | False | 2417.94 | 0 | 3891526 | 149611 | None | code54 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module. (PWD Electrical CSR of 2023-2024, pg no-9 of 105, Si.no-3.6.4) | Each | 360.57 | 360.57 | 6.0 | False | None | None | False | None | False | 2163.42 | 0 | 3891527 | 149611 | None | code55 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch (PWD Electrical CSR of 2023-2024, pg no-9 of 105, Si.no-3.6.9) | Each | 329.26 | 329.26 | 10.0 | False | None | None | False | None | False | 3292.6 | 0 | 3891528 | 149611 | None | code56 | Supplying PVC/Gi Flexible conduit pipe.. mm dia fxing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddies at an interval of 300mm using NF screws on the either end of the pipe terminated completely. 25mm (PWD Electrical CSR of 2023-2024, pg no-3 of 105, Si.no-1.9.2) | Each | 22.22 | 22.22 | 30.0 | False | None | None | False | None | False | 666.6 | 0 | 3891529 | 149611 | None | code57 | Supplying and Fixing Metal Fan Box with Round Hook. (PWD Electrical CSR of 2023-2024, pg no-4 of 105, Si.no-1.13) | No | 118.17 | 118.17 | 8.0 | False | None | None | False | None | False | 945.36 | 0 | 3891530 | 149611 | None | code58 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box (PWD Electrical CSR of 2023-2024, pg no-5 of 105, Si.no-2.2.1) | Each | 271.69 | 271.69 | 6.0 | False | None | None | False | None | False | 1630.14 | 0 | 3891531 | 149611 | None | code59 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box (PWD Electrical CSR of 2023-2024, pg no-5 of 105, Si.no-2.2.2) | Each | 382.79 | 382.79 | 6.0 | False | None | None | False | None | False | 2296.74 | 0 | 3891532 | 149611 | None | code60 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box (PWD Electrical CSR of 2023-2024, pg no-5 of 105, Si.no-2.2.3) | Mtr | 560.55 | 560.55 | 4.0 | False | None | None | False | None | False | 2242.2 | 0 | 3891533 | 149611 | None | code61 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm (PWD Electrical CSR of 2023-2024, pg no-5 of 105, Si.no-2.3.2) | Mtr | 26.26 | 26.26 | 60.0 | False | None | None | False | None | False | 1575.6 | 0 | 3891534 | 149611 | None | code62 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm (PWD Electrical CSR of 2023-2024, pg no-5 of 105, Si.no-2.3.3) | Mtr | 42.42 | 42.42 | 40.0 | False | None | None | False | None | False | 1696.8 | 0 | 3891535 | 149611 | None | code63 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm (PWD Electrical CSR of 2023-2024, pg no-5 of 105, Si.no-2.3.4) | Mtr | 63.63 | 63.63 | 30.0 | False | None | None | False | None | False | 1908.9 | 0 | 3891536 | 149611 | None | code64 | Supplying and drawing PVC insulated flexible copper wire of approved make a per IS: 694 : 2010. 23/0.0052" (PWD Electrical CSR of 2023-2024, pg no-6 of 105, Si.no-2.4.5) | Mtr | 23.23 | 23.23 | 12.0 | False | None | None | False | None | False | 278.76 | 0 | 3891537 | 149611 | None | code65 | supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screws. 60mm (PWD Electrical CSR of 2023-2024, pg no-9 of 105, Si.no-3.10.1) | No. | 8.08 | 8.08 | 8.0 | False | None | None | False | None | False | 64.64 | 0 | 3891538 | 149611 | None | code66 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Bakelite Ceiling Rose (PWD Electrical CSR of 2023-2024, pg no-10 of 105, Si.no-3.14.5) | Each | 78.78 | 78.78 | 10.0 | False | None | None | False | None | False | 787.8 | 0 | 3891539 | 149611 | None | code67 | Supplying of ..... feet - PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input : 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W (PWD Electrical CSR of 2023-2024, pg no-43 of 105, Si.no-11.3.2) | Each | 696.0 | 696.0 | 6.0 | False | None | None | False | None | False | 4176.0 | 0 | 3891540 | 149611 | None | code68 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 Volts, 50 Cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model (PWD Electrical CSR of 2023-2024, pg no-30 of 105, Si.no-6.3.1) | Each | 3013.84 | 3013.84 | 3.0 | False | None | None | False | None | False | 9041.52 | 0 | 3891541 | 149611 | None | code69 | Fixing all types and all capacities of fluorescent /False ceiling/spot light /CFL/LED fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076' twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling /Rafter / Girders (PWD Electrical CSR of 2023-2024, pg no-56 of 105, Si.no-13.7.1) | Each | 123.22 | 123.22 | 3.0 | False | None | None | False | None | False | 369.66 | 0 | 3891542 | 149611 | None | code70 | Fixing a Ceiling / Wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod with 5amps. Ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. (PWD Electrical CSR of 2023-2024, pg no-57 of 105, Si.no-13.11) | Each | 318.15 | 318.15 | 3.0 | False | None | None | False | None | False | 954.45 | 0 | 3891543 | 149611 | None | code71 | Extra length of GI pipe of class B 19mm dia for down rod. (PWD Electrical CSR of 2023-2024, pg no-57 of 105, Si.no-13.12) | Mtr | 198.97 | 198.97 | 6.0 | False | None | None | False | None | False | 1193.82 | 0 | 3891544 | 149611 | None | code72 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required Confirming to IEC 60898. 6-32 Amps DP (PWD Electrical CSR of 2023-2024, pg no-17 of 105, Si.no-5.18.4) | Each | 746.39 | 746.39 | 4.0 | False | None | None | False | None | False | 2985.56 | 0 | 3891545 | 149611 | None | code73 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. I - Single Door 8Way SP &N (PWD Electrical CSR of 2023-2024, pg no-18 of 105, Si.no-5.19.3) | Each | 1506.92 | 1506.92 | 1.0 | False | None | None | False | None | False | 1506.92 | 0 |
|