createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1725031002425
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd30000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose17-09-2024 17:30:00
tenderQueryClose17-09-2024 17:00:00
technicalBidOpenNone
publishedDate30-08-2024 22:34:08
publishedByPostTP_CO_KDK
publishedByUserKPE15278 - DEEPA H R
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonHarsha
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9739203412
tenderSupplierListNone
tenderSchedule
createdTs1725031002449
version5
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT28730
titleRaising of casing pipes, Construction of platform and installation of necessary materials for existing borewells in Kadakola Town Panchayath Limits
descriptionRaising of casing pipes, Construction of platform and installation of necessary materials for existing borewells in Kadakola Town Panchayath Limits
categoryWORKS
categoryTextWorks
ecv1200000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2455
locationNameDMA Town Panchayat Kadakola
provisionalAmount1200000.0
groupOverheadTotal183535.23
fileNumber15FTG/2022-23/KDK/78
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17250310020000NoneNoneOther WorksInstallation of casing pipe and raising of existing submersible borewells in Kadakola TP limits and Construction of revolving platform and purchase and installation of necessary materials for borewells1016464.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3890868149561Nonecode01Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. (Vol-I SR 2023-24, Item no. 1.17.1, Page No.10)Cum269.86269.8669.9FalseNoneNoneFalseNoneFalse18863.2140
3890869149561Nonecode02Supply of ISI mark 175mm nominal bore, plain and Steel Casing Pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. (WS& UGD works Common SR-2023-24 P-143 I No 12.32)m1990.991990.9945.0FalseNoneNoneFalseNoneFalse89594.550
3890870149561Nonecode03Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge. (Vol-5 SR-2023-24, P-153, Item No.12. 34)Each168.92168.9230.0FalseNoneNoneFalseNoneFalse5067.60
3890871149561Nonecode04Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR Vol-01, 2023-24, Item no. 2.1.2, Page No.15)Cum5833.925833.9220.16FalseNoneNoneFalseNoneFalse117611.82720
3890872149561Nonecode05Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (PWD SR Vol-01, 2023-24, Item no. 2.1.6, Page No.15)Cum6430.296430.2918.0FalseNoneNoneFalseNoneFalse115745.220
3890873149561Nonecode06Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. 7.50 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00" (WS& UGD works Common SR-2023-24 P-152, NO 13.15.7, SOR CODE-P150F)Each42034.342034.34.0FalseNoneNoneFalseNoneFalse168137.20
3890874149561Nonecode07Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per pecifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work, (WS& UGD works Common SR-2023-24 P-156 ,I No 13.32)Job6695.06695.08.0FalseNoneNoneFalseNoneFalse53560.00
3890875149561Nonecode08Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For : Medium Duty GI pipe of 50mm dia (WS& UGD works Common SR-2023-24 P-127, NO 11.2.6)m601.52601.52144.0FalseNoneNoneFalseNoneFalse86618.880
3890876149561Nonecode09Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. (WS& UGD works Common SR-2022 P-154, NO 13.22.3 SOR CODE-P230,) 1*3*4 sqmm139.05139.05400.0FalseNoneNoneFalseNoneFalse55620.00
3890877149561Nonecode10Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for, For 50 mm dia GI elbow(WS& UGD works Common SR-2023-24 P-129, NO 11.7.6)Each275.01275.0116.0FalseNoneNoneFalseNoneFalse4400.160
3890878149561Nonecode11Supply and delivery at site of brand new best make Non-Return Valve as per IS 778/1984 with ISI Mark and as per its latest amendments (WS& UGD works Common SR-2023-24 P-154, NO 13.25.1, SOR CODE-P260A) Size 50 mmEach1287.51287.54.0FalseNoneNoneFalseNoneFalse5150.00
3890879149561Nonecode12Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For : Medium Duty GI pipe of 40mm dia (WS& UGD works Common SR- 2023-24 P-127, NO 11.2.5)m502.64502.6448.0FalseNoneNoneFalseNoneFalse24126.720
3890880149561Nonecode13Fabricating, Supplying and mounting MS Box Made out ….. SWG Suitable for Floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arreangement, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete (2023-24 ELE. SR P-20, I-5.42.2) 16 SWGSqm0.440.4492000.0FalseNoneNoneFalseNoneFalse40480.00
3890881149561Nonecode14Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6mm. (ELE CSR 2023-24, P No-20, NO-5.41.1)m314.15314.154.8FalseNoneNoneFalseNoneFalse1507.920
3890882149561Nonecode15Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using apered inverted wooden plugs screws.,20"x20"x2.5", (2023-24 ELE. SR P-14, I-5.6.6)Each335.91335.914.0FalseNoneNoneFalseNoneFalse1343.640
3890883149561Nonecode16Supply, installing, testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter, 6 to 15 HP pumps (WS& UGD works Common SR-223-24 P-124 NO.13.23)Each18025.018025.04.0FalseNoneNoneFalseNoneFalse72100.00
3890884149561Nonecode17Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.63Amps, (2023-24 ELE. SR P-14, I-5.7.3)Each413.03413.034.0FalseNoneNoneFalseNoneFalse1652.120
3890885149561Nonecode18Supplying and fixing Miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32A TPN, (2023-24 ELE. SR P-17, I-5.18.7)Each1768.511768.514.0FalseNoneNoneFalseNoneFalse7074.040
3890886149561Nonecode19Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to stablished through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (WS& UGD works Common SR-2023-24 P-157, 13.39)Job3862.53862.54.0FalseNoneNoneFalseNoneFalse15450.00
3890887149561Nonecode20Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work (PWD Vol-02 SR 2023-24, Item no. 6.7, Page No.13)Cum10510.0810510.084.3199FalseNoneNoneFalseNoneFalse45402.4945920
3890888149561Nonecode21Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 90mm(weight of pipe -1.313 kg): WS & UGD, CSR 2023-24, VOL-5, P No-120, NO-10.14.17)m341.96341.96108.0FalseNoneNoneFalseNoneFalse36931.680
3890889149561Nonecode22Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O“ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For Suilce Valve of PN -10.0 and 80mm (WS&UGD CSR 2023-24, P-22, I-2.23.2)Each10704.7910704.794.0FalseNoneNoneFalseNoneFalse42819.160
3890890149561Nonecode23Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications, (SR 2023-24 ,VOL-1 P NO 35, I NO 1.10)Cum164.8164.843.74FalseNoneNoneFalseNoneFalse7208.3520
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17250352780000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17250352780000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17250352780000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17250352780000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17250352780000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17250352780000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17250352780000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17250352780000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17250352780000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17250352780000NoneNoneELIGIBILITYBanker DetailsNone
17250352900000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17250352960000NoneNoneELIGIBILITYBefore Quoting the rates tenderer should read the bid document carefullyNone
17250353020000NoneNoneELIGIBILITYThe Tender Processing Fee shall not be refundableNone
17250353080000NoneNoneELIGIBILITYThe Employer reserves the rights to Reject or accept any or all the tenders without assigning any reasonsNone
17250353140000NoneNoneELIGIBILITYBidders should abide to all the Terms and Conditions attached.None
17250353200000NoneNoneELIGIBILITYUpload relevant documents as per tender documentNone
17250353250000NoneNoneELIGIBILITYBidder should be Pay Difference amount in the name Chief Officer,Kadakola TPNone
17250353420000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the Standard Tender documents KW-1None
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Audited CA certificate of Annual Turnover turnover should be equivalent to Rs. 12.00 lakhs for any two years in the past 5 financial yearsTrueTechnical Bid
Similar Work done certificate issued by not below the rank of Executive EngineerTrueTechnical Bid
PWD Class IV and above contractor registration certificateTrueTechnical Bid
Unconditional banker certificate of Rs 4.00 Lakhs in our bank format tender DocumentTrueTechnical Bid
Upload relevant documents as per tender documentFalseTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone