1725021851000 | 0 | None | None | Other Works | Construction of mini bridge manoligujji narayana poojary house road in Sagri ward (SC) | 840655.62 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3889916 | 149492 | None | code01 | Diversion of water course by providing Coffer dams or bunds or islands as may be necessary for piers and abutments foundations, bailing out or pumping water during excavation and until completion etc., including cost of materials, labour, HOM complete as per specifications. beyond 1.50 mtrs depth upto & including 3m depth. beyond 3.00 mtrs depth upto & including 4.5m depth. (Pg 113, Item No. 37.41.3 Vol 3 PWDSR 2018-19) | Cum | 725.76 | 725.76 | 96.0 | False | None | None | False | None | False | 69672.96 | 0 | 3889917 | 149492 | None | code02 | Demolishing R.C.C. work manually/ by mechanical means including stack ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge (Pg 187, Item No. 19.3 Vol 2 PWDSR 2024-25) | Cum | 2717.12 | 2717.12 | 14.0 | False | None | None | False | None | False | 38039.68 | 0 | 3889918 | 149492 | None | code03 | Earth work excavation by manual means for drains,canals, waste weir draft,approach channels, key trench, foundation of Bridges and such similar works,as per drawing and technical specifications, including setting out, shoring,strutting, barricading, caution lights, excavated surface leveled and sides neatlydressed disposing off or leveling the excavated stuff or sorting & stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth Sl. No.1.5.1 P.No. 6/CSR 2024-2025 Vol-1 | Cum | 334.88 | 334.88 | 34.08 | False | None | None | False | None | False | 11412.7104 | 0 | 3889919 | 149492 | None | code04 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (Depth upto 3.00m)(Pg 8, Item No. 1.14.1 Vol I PWDSR 2024-25) | Cum | 114.24 | 114.24 | 34.08 | False | None | None | False | None | False | 3893.2992 | 0 | 3889920 | 149492 | None | code05 | Providing and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications (Pg 64, Item No. 9 Vol I A130A PWDSR 2024-25) | Cum | 1784.16 | 1784.16 | 12.18 | False | None | None | False | None | False | 21731.0688 | 0 | 3889921 | 149492 | None | code06 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates (Pg 15, Item No. 2.1.3 Vol I PWDSR 2024-25) | Cum | 6707.68 | 6707.68 | 5.73 | False | None | None | False | None | False | 38435.0064 | 0 | 3889922 | 149492 | None | code07 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No.3.7, 406 P.No. 16/CSR 2024-25 VOL-3 | Tonne | 96804.96 | 96804.96 | 3.1841 | False | None | None | False | None | False | 308236.673136 | 0 | 3889923 | 149492 | None | code08 | Providing and laying in Cement Concrete for all Basement & surface levelworks, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevantIS Codes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, including alllead & lifts, cost of all materials of quality, labour, Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( Page no 16, item no2.3.1 , UNI SR 2024-25) | Cum | 7789.94 | 7789.94 | 38.61 | False | None | None | False | None | False | 300769.5834 | 0 | 3889924 | 149492 | None | code09 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with alllifts and lead, transportation to site, spreading, grading to required slope andcompacting to meet the requirement complete as per specifications, includingcost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.If the height of embankment construction is more than for works under foul & sullage situation PWD SR 2024-25 Vol:1 P.NO.6.No:1.8 vol-1. | Cum | 530.88 | 530.88 | 68.0 | False | None | None | False | None | False | 36099.84 | 0 | 3889925 | 149492 | None | code10 | Providing weep holes in Brick masonry/Plain/ Reinforcedconcrete abutment, wing wall/ return wall with 100 mm diaAC pipe, extending through the full width of the structure withslope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications (Pg 99, Item No. 12.1 Vol 3 PWDSR 2024-25) | Mtr | 154.56 | 154.56 | 80.0 | False | None | None | False | None | False | 12364.8 | 0 |
|