createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1725018306174
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd1015000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose30-09-2024 16:00:00
tenderQueryClose12-09-2024 16:00:00
technicalBidOpen03-10-2024 16:00:00
publishedDate30-08-2024 18:58:25
publishedByPostKHB_EE_CO_BNG
publishedByUserKPE11677 - SHIVASHANKARAPPA K H
bidValidityPeriod180
noOfCalls1
preBidMeetingDate13-09-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVASHANKARAPPA K H
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1725018306189
version6
createdDateNone
modifiedDateNone
tenderNumberKHB/2024-25/BD/WORK_INDENT271
titleConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School at Yallapura Village, Magadi Taluk, Ramanagara District
descriptionConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School at Yallapura Village, Magadi Taluk, Ramanagara District
categoryWORKS
categoryTextWorks
ecv67515740.87
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount67515741.0
groupOverheadTotalNone
fileNumberKHB/CE/AE-1/MWD/399/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17250183060000NoneNoneBuildingsConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School at Yallapura Village, Magadi Taluk, Ramanagara District67515740.87
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3888852149429Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. - In all kinds of soils upto 300 mm depthCum95.095.0276.0FalseNoneNoneFalseNoneFalse26220.00
3888853149429Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work - In all kinds of soils - Depth upto 3 mCum102.0102.0988.796FalseNoneNoneFalseNoneFalse100857.1920
3888854149429Nonecode03Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- n all kinds of soils - In ordinary/soft rock without blasting upto 1.5 m depthCum363.0363.0191.343FalseNoneNoneFalseNoneFalse69457.5090
3888855149429Nonecode04Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. - In all kinds of soils Depth upto 1.5 mCum242.0242.095.672FalseNoneNoneFalseNoneFalse23152.6240
3888856149429Nonecode05Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. - Depth exceeding 1.5 m, but not exceeding 3 mCum331.0331.0560.0FalseNoneNoneFalseNoneFalse185360.00
3888857149429Nonecode06Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm118.0118.01068.366FalseNoneNoneFalseNoneFalse126067.1880
3888858149429Nonecode07Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.Cum2682.02682.0104.8584FalseNoneNoneFalseNoneFalse281230.22880
3888859149429Nonecode08Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5664.05664.0168.051FalseNoneNoneFalseNoneFalse951840.8640
3888860149429Nonecode09Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum5989.05989.095.838FalseNoneNoneFalseNoneFalse573973.7820
3888861149429Nonecode10Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - For FOOTINGSCum6336.06336.0438.055FalseNoneNoneFalseNoneFalse2775516.480
3888862149429Nonecode11Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) -M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For PEDESTAL & UG SUMPCum6336.06336.0236.309FalseNoneNoneFalseNoneFalse1497253.8240
3888863149429Nonecode12Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Columns, Plinth Beam, Roof Beam, Roof Slab, Staircase, Lintel, Cill and Chejja - GROUND FLOORCum6843.06843.0337.524FalseNoneNoneFalseNoneFalse2309676.7320
3888864149429Nonecode13Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Columns, Plinth Beam, Roof Beam, Roof Slab, Staircase, Lintel, Cill and Chejja - FIRST FLOORCum6911.436911.43239.017FalseNoneNoneFalseNoneFalse1651949.264310
3888865149429Nonecode14Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Columns, Plinth Beam, Roof Beam, Roof Slab, Staircase, Lintel, Cill and Chejja - SECOND FLOORCum6979.866979.86235.74FalseNoneNoneFalseNoneFalse1645432.19640
3888866149429Nonecode15Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Columns, Plinth Beam, Roof Beam, Roof Slab, Staircase, Lintel, Cill and Chejja - THIRD FLOORCum7048.297048.29235.588FalseNoneNoneFalseNoneFalse1660492.544520
3888867149429Nonecode16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Columns, Roof Beam, Roof Slab, Staircase, Lintel, Cill and Chejja - FOURTH FLOORCum7116.727116.72235.588FalseNoneNoneFalseNoneFalse1676613.831360
3888868149429Nonecode17Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Columns, Roof Beam, Roof Slab, Staircase, Lintel, Cill and Chejja - TERRACE FLOORCum7185.157185.1545.512FalseNoneNoneFalseNoneFalse327010.54680
3888869149429Nonecode18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - GROUND FLOORTonne89457.089457.085.601FalseNoneNoneFalseNoneFalse7657608.6570
3888870149429Nonecode19Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - FIRST FLOORTonne90351.5790351.5716.86FalseNoneNoneFalseNoneFalse1523327.47020
3888871149429Nonecode20Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - SECOND FLOORTonne91246.1491246.1416.761FalseNoneNoneFalseNoneFalse1529376.552540
3888872149429Nonecode21Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - THIRD FLOORTonne92140.7192140.7116.761FalseNoneNoneFalseNoneFalse1544370.440310
3888873149429Nonecode22Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - FOURTH FLOORTonne93035.2893035.2816.629FalseNoneNoneFalseNoneFalse1547083.671120
3888874149429Nonecode23Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - TERRACE FLOORTonne93929.8593929.853.748FalseNoneNoneFalseNoneFalse352049.07780
3888875149429Nonecode24Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum266.0266.0274.633FalseNoneNoneFalseNoneFalse73052.3780
3888876149429Nonecode25Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum433.0433.0334.08FalseNoneNoneFalseNoneFalse144656.640
3888877149429Nonecode26Loading and Unloading of Stone Boulder /Stone aggregates /Sand /Kankar /Moorum. (Tipper 14 m3) - Taking output 10 t load and lead 10 km = 100 kmCum105.2105.2508.081FalseNoneNoneFalseNoneFalse53450.12120
3888878149429Nonecode27Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - GROUND FLOORSqm1310.01310.0304.543FalseNoneNoneFalseNoneFalse398951.330
3888879149429Nonecode28Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FIRST FLOORSqm1323.11323.1326.672FalseNoneNoneFalseNoneFalse432219.72320
3888880149429Nonecode29Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - SECOND FLOORSqm1336.21336.2326.672FalseNoneNoneFalseNoneFalse436499.12640
3888881149429Nonecode30Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - THIRD FLOORSqm1349.31349.3326.672FalseNoneNoneFalseNoneFalse440778.52960
3888882149429Nonecode31Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FOURTH FLOORSqm1362.41362.4326.672FalseNoneNoneFalseNoneFalse445057.93280
3888883149429Nonecode32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - TERRACE FLOORSqm1375.51375.5209.44FalseNoneNoneFalseNoneFalse288084.720
3888884149429Nonecode33Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - GROUND FLOORSqm1231.01231.0278.449FalseNoneNoneFalseNoneFalse342770.7190
3888885149429Nonecode34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FIRST FLOORSqm1243.311243.31261.953FalseNoneNoneFalseNoneFalse325688.784430
3888886149429Nonecode35Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - SECOND FLOORCum1255.621255.62261.953FalseNoneNoneFalseNoneFalse328913.425860
3888887149429Nonecode36Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - THIRD FLOORSqm1267.931267.93261.953FalseNoneNoneFalseNoneFalse332138.067290
3888888149429Nonecode37Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FOURTH FLOORSqm1280.241280.24261.953FalseNoneNoneFalseNoneFalse335362.708720
3888889149429Nonecode38Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - GROUND FLOORSqm1104.01104.09.27FalseNoneNoneFalseNoneFalse10234.080
3888890149429Nonecode39Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FIRST FLOORSqm1115.041115.04112.629FalseNoneNoneFalseNoneFalse125585.840160
3888891149429Nonecode40Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - SECOND FLOORCum1126.081126.08112.629FalseNoneNoneFalseNoneFalse126829.264320
3888892149429Nonecode41Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - THIRD FLOORSqm1137.121137.12112.629FalseNoneNoneFalseNoneFalse128072.688480
3888893149429Nonecode42Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FOURTH FLOORSqm1148.161148.16112.629FalseNoneNoneFalseNoneFalse129316.112640
3888894149429Nonecode43Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - GROUND FLOORSqm255.0255.0663.515FalseNoneNoneFalseNoneFalse169196.3250
3888895149429Nonecode44Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - FIRST FLOORSqm257.55257.55465.088FalseNoneNoneFalseNoneFalse119783.41440
3888896149429Nonecode45Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - SECOND FLOORSqm260.1260.1465.088FalseNoneNoneFalseNoneFalse120969.38880
3888897149429Nonecode46Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - THIRD FLOORSqm262.65262.65465.088FalseNoneNoneFalseNoneFalse122155.36320
3888898149429Nonecode47Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - FOURTH FLOORSqm265.2265.2465.088FalseNoneNoneFalseNoneFalse123341.33760
3888899149429Nonecode48Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - TERRACE FLOORSqm267.75267.7521.68FalseNoneNoneFalseNoneFalse5804.820
3888900149429Nonecode49Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - GROUND FLOORSqm349.0349.01209.372FalseNoneNoneFalseNoneFalse422070.8280
3888901149429Nonecode50Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - FIRST FLOORSqm352.49352.491583.05FalseNoneNoneFalseNoneFalse558009.29450
3888902149429Nonecode51Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - SECOND FLOORSqm355.98355.981583.05FalseNoneNoneFalseNoneFalse563534.1390
3888903149429Nonecode52Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - THIRD FLOORSqm359.47359.471583.05FalseNoneNoneFalseNoneFalse569058.98350
3888904149429Nonecode53Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - FOURTH FLOORSqm362.96362.961583.05FalseNoneNoneFalseNoneFalse574583.8280
3888905149429Nonecode54Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - TERRACE FLOORSqm366.45366.4578.96FalseNoneNoneFalseNoneFalse28934.8920
3888906149429Nonecode55Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - GROUND FLOORSqm371.0371.0720.783FalseNoneNoneFalseNoneFalse267410.4930
3888907149429Nonecode56Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - FIRST FLOORSqm374.71374.71476.89FalseNoneNoneFalseNoneFalse178695.45190
3888908149429Nonecode57Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - SECOND FLOORSqm378.42378.42476.89FalseNoneNoneFalseNoneFalse180464.71380
3888909149429Nonecode58Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - THIRD FLOORSqm382.13382.13476.89FalseNoneNoneFalseNoneFalse182233.97570
3888910149429Nonecode59Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - FOURTH FLOORSqm385.84385.84476.89FalseNoneNoneFalseNoneFalse184003.23760
3888911149429Nonecode60Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - TERRACE FLOORSqm389.55389.55377.165FalseNoneNoneFalseNoneFalse146924.625750
3888912149429Nonecode61KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS - GROUND FLOORm33.033.074.4FalseNoneNoneFalseNoneFalse2455.20
3888913149429Nonecode62KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS - FIRST FLOORm33.3333.3387.4FalseNoneNoneFalseNoneFalse2913.0420
3888914149429Nonecode63KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS - SECOND FLOORm33.6633.6687.4FalseNoneNoneFalseNoneFalse2941.8840
3888915149429Nonecode64KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS - THIRD FLOORm33.9933.9987.4FalseNoneNoneFalseNoneFalse2970.7260
3888916149429Nonecode65KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS - FOURTH FLOORm34.3234.3287.4FalseNoneNoneFalseNoneFalse2999.5680
3888917149429Nonecode66KSRB 15.8 : Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) - KSRB 15.8.1 - do - suitable plaster mesh 100mm wide - GROUND FLOORm26.026.0850.0FalseNoneNoneFalseNoneFalse22100.00
3888918149429Nonecode67KSRB 15.8 : Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) - KSRB 15.8.1 - do - suitable plaster mesh 100mm wide - FIRST FLOORm26.2626.261300.0FalseNoneNoneFalseNoneFalse34138.00
3888919149429Nonecode68KSRB 15.8 : Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) - KSRB 15.8.1 - do - suitable plaster mesh 100mm wide- SECOND FLOORm26.5226.521300.0FalseNoneNoneFalseNoneFalse34476.00
3888920149429Nonecode69KSRB 15.8 : Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) - KSRB 15.8.1 - do - suitable plaster mesh 100mm wide - THIRD FLOORm26.7826.781300.0FalseNoneNoneFalseNoneFalse34814.00
3888921149429Nonecode70KSRB 15.8 : Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) - KSRB 15.8.1 - do - suitable plaster mesh 100mm wide - FOURTH FLOORm27.0427.041300.0FalseNoneNoneFalseNoneFalse35152.00
3888922149429Nonecode71Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm - GROUND FLOORSqm1145.01145.081.531FalseNoneNoneFalseNoneFalse93352.9950
3888923149429Nonecode72Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm - FIRST FLOORSqm1156.451156.45321.798FalseNoneNoneFalseNoneFalse372143.29710
3888924149429Nonecode73Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm - SECOND FLOORSqm1167.91167.9321.798FalseNoneNoneFalseNoneFalse375827.88420
3888925149429Nonecode74Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm - THIRD FLOORSqm1179.351179.35321.798FalseNoneNoneFalseNoneFalse379512.47130
3888926149429Nonecode75Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm - FOURTH FLOORSqm1190.81190.8321.798FalseNoneNoneFalseNoneFalse383197.05840
3888927149429Nonecode76Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - GROUND FLOORSqm2085.02085.0460.233FalseNoneNoneFalseNoneFalse959585.8050
3888928149429Nonecode77Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - FIRST FLOORSqm2105.852105.8594.858FalseNoneNoneFalseNoneFalse199756.71930
3888929149429Nonecode78Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - SECOND FLOORSqm2126.72126.794.858FalseNoneNoneFalseNoneFalse201734.50860
3888930149429Nonecode79Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - THIRD FLOORSqm2147.552147.5594.858FalseNoneNoneFalseNoneFalse203712.29790
3888931149429Nonecode80Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - FOURTH FLOORSqm2168.42168.494.858FalseNoneNoneFalseNoneFalse205690.08720
3888932149429Nonecode81Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. - GROUND FLOORSqm5328.05328.034.225FalseNoneNoneFalseNoneFalse182350.80
3888933149429Nonecode82Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. - FIRST FLOORSqm5381.285381.2823.385FalseNoneNoneFalseNoneFalse125841.23280
3888934149429Nonecode83Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. - SECOND FLOORSqm5434.565434.5623.385FalseNoneNoneFalseNoneFalse127087.18560
3888935149429Nonecode84Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. - THIRD FLOORSqm5487.845487.8423.385FalseNoneNoneFalseNoneFalse128333.13840
3888936149429Nonecode85Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. - FOURTH FLOORSqm5541.125541.1223.385FalseNoneNoneFalseNoneFalse129579.09120
3888937149429Nonecode86Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - GROUND FLOORSqm889.0889.07.905FalseNoneNoneFalseNoneFalse7027.5450
3888938149429Nonecode87Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - FIRST FLOORSqm897.89897.8974.509FalseNoneNoneFalseNoneFalse66900.886010
3888939149429Nonecode88Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - SECOND FLOORSqm906.78906.7874.509FalseNoneNoneFalseNoneFalse67563.271020
3888940149429Nonecode89Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - THIRD FLOORSqm915.67915.6774.509FalseNoneNoneFalseNoneFalse68225.656030
3888941149429Nonecode90Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - FOURTH FLOORSqm924.56924.5674.509FalseNoneNoneFalseNoneFalse68888.041040
3888942149429Nonecode91Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - GROUND FLOORSqm1449.01449.059.33FalseNoneNoneFalseNoneFalse85969.170
3888943149429Nonecode92Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - FIRST FLOORSqm1463.491463.49204.106FalseNoneNoneFalseNoneFalse298707.089940
3888944149429Nonecode93Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - SECOND FLOORSqm1477.981477.98204.106FalseNoneNoneFalseNoneFalse301664.585880
3888945149429Nonecode94Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - THIRD FLOORSqm1492.471492.47204.106FalseNoneNoneFalseNoneFalse304622.081820
3888946149429Nonecode95Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - FOURTH FLOORSqm1506.961506.96204.106FalseNoneNoneFalseNoneFalse307579.577760
3888947149429Nonecode96Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - GROUND FLOORCum99600.099600.05.37FalseNoneNoneFalseNoneFalse534852.00
3888948149429Nonecode97Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - FIRST FLOORCum100596.0100596.00.894FalseNoneNoneFalseNoneFalse89932.8240
3888949149429Nonecode98Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - SECOND FLOORCum101592.0101592.00.894FalseNoneNoneFalseNoneFalse90823.2480
3888950149429Nonecode99Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - THIRD FLOORCum102588.0102588.00.894FalseNoneNoneFalseNoneFalse91713.6720
3888951149429Nonecode100Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - FOURTH FLOORCum103584.0103584.00.894FalseNoneNoneFalseNoneFalse92604.0960
3888952149429Nonecode101Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - TERRACE FLOORCum104580.0104580.00.083FalseNoneNoneFalseNoneFalse8680.140
3888953149429Nonecode102Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - GROUND FLOORNo1016.01016.010.0FalseNoneNoneFalseNoneFalse10160.00
3888954149429Nonecode103Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - FIRST FLOORNo1026.161026.1613.0FalseNoneNoneFalseNoneFalse13340.080
3888955149429Nonecode104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - SECOND FLOORNo1036.321036.3213.0FalseNoneNoneFalseNoneFalse13472.160
3888956149429Nonecode105Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - THIRD FLOORNo1046.481046.4813.0FalseNoneNoneFalseNoneFalse13604.240
3888957149429Nonecode106Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - FOURTH FLOORNo1056.641056.6413.0FalseNoneNoneFalseNoneFalse13736.320
3888958149429Nonecode107Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - TERRACE FLOORNo1066.81066.81.0FalseNoneNoneFalseNoneFalse1066.80
3888959149429Nonecode108Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - GROUND FLOORSqm3005.03005.019.68FalseNoneNoneFalseNoneFalse59138.40
3888960149429Nonecode109Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - FIRST FLOORSqm3035.053035.0527.3FalseNoneNoneFalseNoneFalse82856.8650
3888961149429Nonecode110Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - SECOND FLOORSqm3065.13065.127.3FalseNoneNoneFalseNoneFalse83677.230
3888962149429Nonecode111Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - THIRD FLOORSqm3095.153095.1527.3FalseNoneNoneFalseNoneFalse84497.5950
3888963149429Nonecode112Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - FOURTH FLOORSqm3125.23125.227.3FalseNoneNoneFalseNoneFalse85317.960
3888964149429Nonecode113Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - TERRACE FLOORSqm3155.253155.252.52FalseNoneNoneFalseNoneFalse7951.230
3888965149429Nonecode114Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7444.07444.012.24FalseNoneNoneFalseNoneFalse91114.560
3888966149429Nonecode115Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). - Size 62 x 125mm - GROUND FLOORm764.0764.09.9FalseNoneNoneFalseNoneFalse7563.60
3888967149429Nonecode116Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). - Size 62 x 125mm - FIRST FLOORm771.64771.6499.0FalseNoneNoneFalseNoneFalse76392.360
3888968149429Nonecode117Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). - Size 62 x 125mm - SECOND FLOORm779.28779.2899.0FalseNoneNoneFalseNoneFalse77148.720
3888969149429Nonecode118Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). - Size 62 x 125mm - THIRD FLOORm786.92786.9299.0FalseNoneNoneFalseNoneFalse77905.080
3888970149429Nonecode119Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). - Size 62 x 125mm - FOURTH FLOORm794.56794.5699.0FalseNoneNoneFalseNoneFalse78661.440
3888971149429Nonecode120Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness - GROUND FLOORSqm3485.03485.03.15FalseNoneNoneFalseNoneFalse10977.750
3888972149429Nonecode121Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness - FIRST FLOORSqm3519.853519.8531.5FalseNoneNoneFalseNoneFalse110875.2750
3888973149429Nonecode122Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness - SECOND FLOORSqm3554.73554.731.5FalseNoneNoneFalseNoneFalse111973.050
3888974149429Nonecode123Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness - THIRD FLOORSqm3589.553589.5531.5FalseNoneNoneFalseNoneFalse113070.8250
3888975149429Nonecode124Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness - FOURTH FLOORSqm3624.43624.431.5FalseNoneNoneFalseNoneFalse114168.60
3888976149429Nonecode125Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - GROUND FLOORSqm6734.06734.044.775FalseNoneNoneFalseNoneFalse301514.850
3888977149429Nonecode126Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - FIRST FLOORSqm6801.346801.3432.625FalseNoneNoneFalseNoneFalse221893.71750
3888978149429Nonecode127Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - SECOND FLOORSqm6868.686868.6832.625FalseNoneNoneFalseNoneFalse224090.6850
3888979149429Nonecode128Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - THIRD FLOORSqm6936.026936.0232.625FalseNoneNoneFalseNoneFalse226287.65250
3888980149429Nonecode129Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - FOURTH FLOORSqm7003.367003.3632.625FalseNoneNoneFalseNoneFalse228484.620
3888981149429Nonecode130Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - GROUND FLOORSqm5719.05719.02.64FalseNoneNoneFalseNoneFalse15098.160
3888982149429Nonecode131Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - FIRST FLOORSqm5776.195776.1927.42FalseNoneNoneFalseNoneFalse158383.12980
3888983149429Nonecode132Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - SECOND FLOORSqm5833.385833.3827.42FalseNoneNoneFalseNoneFalse159951.27960
3888984149429Nonecode133Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - THIRD FLOORSqm5890.575890.5727.42FalseNoneNoneFalseNoneFalse161519.42940
3888985149429Nonecode134Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - FOURTH FLOORSqm5947.765947.7627.42FalseNoneNoneFalseNoneFalse163087.57920
3888986149429Nonecode135Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. - GROUND FLOORNo1052.01052.010.0FalseNoneNoneFalseNoneFalse10520.00
3888987149429Nonecode136Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. -FIRST FLOORNo1062.521062.5213.0FalseNoneNoneFalseNoneFalse13812.760
3888988149429Nonecode137Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. - SECOND FLOORNo1073.041073.0413.0FalseNoneNoneFalseNoneFalse13949.520
3888989149429Nonecode138Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. -THIRD FLOORNo1083.561083.5613.0FalseNoneNoneFalseNoneFalse14086.280
3888990149429Nonecode139Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. - FOURTH FLOORNo1094.081094.0813.0FalseNoneNoneFalseNoneFalse14223.040
3888991149429Nonecode140Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm - GROUND FLOOREach435.0435.020.0FalseNoneNoneFalseNoneFalse8700.00
3888992149429Nonecode141Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm - FIRST FLOOREach439.35439.3526.0FalseNoneNoneFalseNoneFalse11423.10
3888993149429Nonecode142Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm - SECOND FLOOREach443.7443.726.0FalseNoneNoneFalseNoneFalse11536.20
3888994149429Nonecode143Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm - THIRD FLOOREach448.05448.0526.0FalseNoneNoneFalseNoneFalse11649.30
3888995149429Nonecode144Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm - FOURTH FLOOREach452.4452.426.0FalseNoneNoneFalseNoneFalse11762.40
3888996149429Nonecode145Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete - GROUND FLOOREach236.0236.010.0FalseNoneNoneFalseNoneFalse2360.00
3888997149429Nonecode146Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete - FIRST FLOOREach238.36238.3613.0FalseNoneNoneFalseNoneFalse3098.680
3888998149429Nonecode147Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete - SECOND FLOOREach240.72240.7213.0FalseNoneNoneFalseNoneFalse3129.360
3888999149429Nonecode148Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete - THIRD FLOOREach243.08243.0813.0FalseNoneNoneFalseNoneFalse3160.040
3889000149429Nonecode149Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete - FOURTH FLOOREach245.44245.4413.0FalseNoneNoneFalseNoneFalse3190.720
3889001149429Nonecode150Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm - GROUND FLOOREach249.0249.020.0FalseNoneNoneFalseNoneFalse4980.00
3889002149429Nonecode151Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm -FIRST FLOOREach251.49251.4926.0FalseNoneNoneFalseNoneFalse6538.740
3889003149429Nonecode152Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm - SECOND FLOOREach253.98253.9826.0FalseNoneNoneFalseNoneFalse6603.480
3889004149429Nonecode153Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm -THIRD FLOOREach256.47256.4726.0FalseNoneNoneFalseNoneFalse6668.220
3889005149429Nonecode154Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm - FOURTH FLOOREach258.96258.9626.0FalseNoneNoneFalseNoneFalse6732.960
3889006149429Nonecode155Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - GROUND FLOORNo275.0275.040.0FalseNoneNoneFalseNoneFalse11000.00
3889007149429Nonecode156Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - FIRST FLOORNo277.75277.75156.0FalseNoneNoneFalseNoneFalse43329.00
3889008149429Nonecode157Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - SECOND FLOORNo280.5280.5156.0FalseNoneNoneFalseNoneFalse43758.00
3889009149429Nonecode158Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - THIRD FLOORNo283.25283.25156.0FalseNoneNoneFalseNoneFalse44187.00
3889010149429Nonecode159Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - FOURTH FLOORNo286.0286.0156.0FalseNoneNoneFalseNoneFalse44616.00
3889011149429Nonecode160Teak wood beading - GROUND FLOORm60.060.046.8FalseNoneNoneFalseNoneFalse2808.00
3889012149429Nonecode161Teak wood beading - FIRST FLOORm60.660.667.6FalseNoneNoneFalseNoneFalse4096.560
3889013149429Nonecode162Teak wood beading - SECOND FLOORm61.261.267.6FalseNoneNoneFalseNoneFalse4137.120
3889014149429Nonecode163Teak wood beading - THIRD FLOORm61.861.867.6FalseNoneNoneFalseNoneFalse4177.680
3889015149429Nonecode164Teak wood beading - FOURTH FLOORm62.462.467.6FalseNoneNoneFalseNoneFalse4218.240
3889016149429Nonecode165Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - GROUND FLOORKgs183.0183.0853.47FalseNoneNoneFalseNoneFalse156185.010
3889017149429Nonecode166Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - FIRST FLOORKgs184.83184.831240.65FalseNoneNoneFalseNoneFalse229309.33950
3889018149429Nonecode167Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - SECOND FLOORKgs186.66186.661240.65FalseNoneNoneFalseNoneFalse231579.7290
3889019149429Nonecode168Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - THIRD FLOORKgs188.49188.491240.65FalseNoneNoneFalseNoneFalse233850.11850
3889020149429Nonecode169Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - FOURTH FLOORKgs190.32190.321240.65FalseNoneNoneFalseNoneFalse236120.5080
3889021149429Nonecode170Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - TERRACE FLOORKgs192.22192.2222.5FalseNoneNoneFalseNoneFalse4324.950
3889022149429Nonecode171Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - GROUND FLOORKgs565.0565.0254.503FalseNoneNoneFalseNoneFalse143794.1950
3889023149429Nonecode172Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - FIRST FLOORKgs570.65570.65106.78FalseNoneNoneFalseNoneFalse60934.0070
3889024149429Nonecode173Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - SECOND FLOORKgs576.3576.3106.78FalseNoneNoneFalseNoneFalse61537.3140
3889025149429Nonecode174Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - THIRD FLOORKgs581.95581.95106.78FalseNoneNoneFalseNoneFalse62140.6210
3889026149429Nonecode175Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - FOURTH FLOORKgs587.6587.6106.78FalseNoneNoneFalseNoneFalse62743.9280
3889027149429Nonecode176Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - GROUND FLOORSqm279.0279.031.08FalseNoneNoneFalseNoneFalse8671.320
3889028149429Nonecode177Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - FIRST FLOORSqm281.79281.79213.781FalseNoneNoneFalseNoneFalse60241.347990
3889029149429Nonecode178Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - SECOND FLOORSqm284.58284.58213.781FalseNoneNoneFalseNoneFalse60837.796980
3889030149429Nonecode179Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - THIRD FLOORSqm287.37287.37213.781FalseNoneNoneFalseNoneFalse61434.245970
3889031149429Nonecode180Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.- FOURTH FLOORSqm290.16290.16213.781FalseNoneNoneFalseNoneFalse62030.694960
3889032149429Nonecode181Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - GROUND FLOORSqm100.0100.01853.387FalseNoneNoneFalseNoneFalse185338.70
3889033149429Nonecode182Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - FIRST FLOORSqm101.0101.02048.138FalseNoneNoneFalseNoneFalse206861.9380
3889034149429Nonecode183Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - SECOND FLOORSqm102.0102.02048.138FalseNoneNoneFalseNoneFalse208910.0760
3889035149429Nonecode184Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - THIRD FLOORSqm103.0103.02048.138FalseNoneNoneFalseNoneFalse210958.2140
3889036149429Nonecode185Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - FOURTH FLOORSqm104.0104.02048.138FalseNoneNoneFalseNoneFalse213006.3520
3889037149429Nonecode186Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - TERRACE FLOORSqm105.0105.0100.64FalseNoneNoneFalseNoneFalse10567.20
3889038149429Nonecode187Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - GROUND FLOORSqm180.0180.01853.387FalseNoneNoneFalseNoneFalse333609.660
3889039149429Nonecode188Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FIRST FLOORSqm181.8181.82048.138FalseNoneNoneFalseNoneFalse372351.48840
3889040149429Nonecode189Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -SECOND FLOORSqm183.6183.62048.138FalseNoneNoneFalseNoneFalse376038.13680
3889041149429Nonecode190Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -THIRD FLOORSqm185.4185.42048.138FalseNoneNoneFalseNoneFalse379724.78520
3889042149429Nonecode191Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FOURTH FLOORSqm187.2187.22048.138FalseNoneNoneFalseNoneFalse383411.43360
3889043149429Nonecode192Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -TERRACE FLOORSqm189.0189.0100.64FalseNoneNoneFalseNoneFalse19020.960
3889044149429Nonecode193Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - GROUND FLOORSqm178.0178.0677.523FalseNoneNoneFalseNoneFalse120599.0940
3889045149429Nonecode194Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FIRST FLOORSqm179.78179.78476.89FalseNoneNoneFalseNoneFalse85735.28420
3889046149429Nonecode195Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - SECOND FLOORSqm181.56181.56476.89FalseNoneNoneFalseNoneFalse86584.14840
3889047149429Nonecode196Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - THIRD FLOORSqm183.34183.34476.89FalseNoneNoneFalseNoneFalse87433.01260
3889048149429Nonecode197Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FOURTH FLOORSqm185.12185.12476.89FalseNoneNoneFalseNoneFalse88281.87680
3889049149429Nonecode198Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - TERRACE FLOORSqm186.9186.9377.165FalseNoneNoneFalseNoneFalse70492.13850
3889050149429Nonecode199Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - GROUND FLOORSqm167.0167.0172.947FalseNoneNoneFalseNoneFalse28882.1490
3889051149429Nonecode200Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FIRST FLOORSqm168.67168.67137.745FalseNoneNoneFalseNoneFalse23233.449150
3889052149429Nonecode201Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -SECOND FLOORSqm170.34170.34137.745FalseNoneNoneFalseNoneFalse23463.48330
3889053149429Nonecode202Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. -THIRD FLOORSqm172.01172.01137.745FalseNoneNoneFalseNoneFalse23693.517450
3889054149429Nonecode203Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FOURTH FLOORSqm173.68173.68137.745FalseNoneNoneFalseNoneFalse23923.55160
3889055149429Nonecode204Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -TERRACE FLOORSqm175.35175.357.298FalseNoneNoneFalseNoneFalse1279.70430
3889056149429Nonecode205Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - GROUND FLOORCum6287.06287.01.781FalseNoneNoneFalseNoneFalse11197.1470
3889057149429Nonecode206Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - FIRST FLOORCum6349.876349.877.886FalseNoneNoneFalseNoneFalse50075.074820
3889058149429Nonecode207Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - SECOND FLOORCum6412.746412.747.886FalseNoneNoneFalseNoneFalse50570.867640
3889059149429Nonecode208Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - THIRD FLOORCum6475.616475.617.886FalseNoneNoneFalseNoneFalse51066.660460
3889060149429Nonecode209Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - FOURTH FLOORCum6538.486538.487.886FalseNoneNoneFalseNoneFalse51562.453280
3889061149429Nonecode210Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - TERRACE FLOORCum6601.356601.3542.192FalseNoneNoneFalseNoneFalse278524.15920
3889062149429Nonecode211Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - FIRST FLOORCum2037.172037.1723.657FalseNoneNoneFalseNoneFalse48193.330690
3889063149429Nonecode212Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - SECOND FLOORCum2057.342057.3423.657FalseNoneNoneFalseNoneFalse48670.492380
3889064149429Nonecode213Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - THIRD FLOORCum2077.512077.5123.657FalseNoneNoneFalseNoneFalse49147.654070
3889065149429Nonecode214Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - FOURTH FLOORCum2097.682097.6823.657FalseNoneNoneFalseNoneFalse49624.815760
3889066149429Nonecode215Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - TERRACE FLOORCum2117.852117.853.024FalseNoneNoneFalseNoneFalse6404.37840
3889067149429Nonecode216Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. - FIRST FLOORSqm825.17825.17134.85FalseNoneNoneFalseNoneFalse111274.17450
3889068149429Nonecode217Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. - SECOND FLOORSqm833.34833.34134.85FalseNoneNoneFalseNoneFalse112375.8990
3889069149429Nonecode218Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. - THIRD FLOORSqm841.51841.51134.85FalseNoneNoneFalseNoneFalse113477.62350
3889070149429Nonecode219Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. - FOURTH FLOORSqm849.68849.68134.85FalseNoneNoneFalseNoneFalse114579.3480
3889071149429Nonecode220Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. - TERRACE FLOORSqm857.85857.85551.93FalseNoneNoneFalseNoneFalse473473.15050
3889072149429Nonecode221Providing & applying high strength non shrink free flow grout (confirming to BS 1881-Part 116 : 1983)comprising of blend of portland cement, graded fillars and chemical additives which impart controlled expansion in the plastic state duly minimizing water demand. (Minimum 25mm thickness around the pipe)No245.0245.0125.0FalseNoneNoneFalseNoneFalse30625.00
3889073149429Nonecode222Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - GROUND FLOORSqm4478.04478.01.5FalseNoneNoneFalseNoneFalse6717.00
3889074149429Nonecode223Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - FIRST FLOORSqm4522.784522.781.5FalseNoneNoneFalseNoneFalse6784.170
3889075149429Nonecode224Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - SECOND FLOORSqm4567.564567.561.5FalseNoneNoneFalseNoneFalse6851.340
3889076149429Nonecode225Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - THIRD FLOORSqm4612.344612.341.5FalseNoneNoneFalseNoneFalse6918.510
3889077149429Nonecode226Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - FOURTH FLOORSqm4657.124657.121.5FalseNoneNoneFalseNoneFalse6985.680
3889078149429Nonecode227Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.Sqm451.0451.0183.6FalseNoneNoneFalseNoneFalse82803.60
3889079149429Nonecode228Providing and laying flooring with burnt stone slabs 10 cms thick rough chistle dressed on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3, , including cost of materials, mortar, labour, curing complete as per specifications.Sqm2388.02388.06.0FalseNoneNoneFalseNoneFalse14328.00
3889080149429Nonecode229Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.Sqm800.0800.0524.765FalseNoneNoneFalseNoneFalse419812.00
3889081149429Nonecode230Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401, For Grading -V MaterialCum2359.02359.0104.953FalseNoneNoneFalseNoneFalse247584.1270
3889082149429Nonecode231Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. - 20 mm nominal dia pipesm379.0379.0256.25FalseNoneNoneFalseNoneFalse97118.750
3889083149429Nonecode232Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. - 25 mm nominal dia pipesm477.0477.0105.2FalseNoneNoneFalseNoneFalse50180.40
3889084149429Nonecode233Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. - 32 mm nominal dia pipesm557.0557.048.0FalseNoneNoneFalseNoneFalse26736.00
3889085149429Nonecode234Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 75mm dia.m217.0217.0324.55FalseNoneNoneFalseNoneFalse70427.350
3889086149429Nonecode235Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 110mm dia.m288.0288.0471.5FalseNoneNoneFalseNoneFalse135792.00
3889087149429Nonecode236Providing and fixing brass bib cock of approved quality : 15 mm nominal boreNo286.0286.0204.0FalseNoneNoneFalseNoneFalse58344.00
3889088149429Nonecode237Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNo305.0305.031.0FalseNoneNoneFalseNoneFalse9455.00
3889089149429Nonecode238Providing and fixing brass stop cock of approved quality : 15 mm nominal boreNo299.0299.0204.0FalseNoneNoneFalseNoneFalse60996.00
3889090149429Nonecode239Providing and fixing brass stop cock of approved quality : 20 mm nominal boreNo305.0305.031.0FalseNoneNoneFalseNoneFalse9455.00
3889091149429Nonecode240Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.Each14212.014212.02.0FalseNoneNoneFalseNoneFalse28424.00
3889092149429Nonecode241Providing and fixing Single flow hand showers with Anti lime jets with 1.5m PVC tube and holder made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class EconomyNo887.0887.042.0FalseNoneNoneFalseNoneFalse37254.00
3889093149429Nonecode242Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer.No4121.04121.02.0FalseNoneNoneFalseNoneFalse8242.00
3889094149429Nonecode243Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach220.0220.099.0FalseNoneNoneFalseNoneFalse21780.00
3889095149429Nonecode244Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Each1220.01220.050.0FalseNoneNoneFalseNoneFalse61000.00
3889096149429Nonecode245Providing and fixing toilet paper holder : C P BrassEach608.0608.02.0FalseNoneNoneFalseNoneFalse1216.00
3889097149429Nonecode246Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 02mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g.No100.0100.042.0FalseNoneNoneFalseNoneFalse4200.00
3889098149429Nonecode247Supply of PPR Gate valve confirming to IS 15801-2008 and DIN Standards 8077/8092 - PPR Gate valve 20mmEach378.0378.023.0FalseNoneNoneFalseNoneFalse8694.00
3889099149429Nonecode248Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screwwith concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each496.0496.042.0FalseNoneNoneFalseNoneFalse20832.00
3889100149429Nonecode249Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Each5562.05562.02.0FalseNoneNoneFalseNoneFalse11124.00
3889101149429Nonecode250Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :100 mm diameterNo257.0257.02.0FalseNoneNoneFalseNoneFalse514.00
3889102149429Nonecode251Providing and fixing Stainless Steel Grab Bar 600 mm Long with all concealed fitting arrangements & all necessary accesories complete - Class - b) PremiumNo8159.08159.03.0FalseNoneNoneFalseNoneFalse24477.00
3889103149429Nonecode252Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach4838.04838.040.0FalseNoneNoneFalseNoneFalse193520.00
3889104149429Nonecode253Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. Do with - 50 mm nominal dia Pipesm721.0721.0210.0FalseNoneNoneFalseNoneFalse151410.00
3889105149429Nonecode254Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. Do with - 40 mm nominal dia Pipesm477.0477.0152.5FalseNoneNoneFalseNoneFalse72742.50
3889106149429Nonecode255Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. Do with - 32 mm nominal dia Pipesm372.0372.0100.0FalseNoneNoneFalseNoneFalse37200.00
3889107149429Nonecode256Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. Do with - 25 mm nominal dia Pipesm296.0296.0160.5FalseNoneNoneFalseNoneFalse47508.00
3889108149429Nonecode257Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. Do with - 20 mm nominal dia Pipesm217.0217.047.0FalseNoneNoneFalseNoneFalse10199.00
3889109149429Nonecode258Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark - For 25 mm dia GM (Copper alloy) Gate valvesEach1169.01169.03.0FalseNoneNoneFalseNoneFalse3507.00
3889110149429Nonecode259Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark - For 32 mm dia GM (Copper alloy) Gate valvesEach1338.01338.04.0FalseNoneNoneFalseNoneFalse5352.00
3889111149429Nonecode260Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark - For 40 mm dia GM (Copper alloy) Gate valvesEach1500.01500.04.0FalseNoneNoneFalseNoneFalse6000.00
3889112149429Nonecode261Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark - For 50 mm dia GM (Copper alloy) Gate valvesEach1688.01688.04.0FalseNoneNoneFalseNoneFalse6752.00
3889113149429Nonecode262Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 mCum262.0262.054.32FalseNoneNoneFalseNoneFalse14231.840
3889114149429Nonecode263Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.Each4236.04236.08.0FalseNoneNoneFalseNoneFalse33888.00
3889115149429Nonecode264Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and coverEach5454.05454.013.0FalseNoneNoneFalseNoneFalse70902.00
3889116149429Nonecode265Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding. - 300 litresEach69986.069986.04.0FalseNoneNoneFalseNoneFalse279944.00
3889117149429Nonecode266Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5 Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without controls which shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Short Point up to 3 mtrs from tapping point to outlet via switchPoint269.0269.065.0FalseNoneNoneFalseNoneFalse17485.00
3889118149429Nonecode267Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5 Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without controls which shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. - Medium point above 3m upto 6m from tapping point to out let via switchPoint379.0379.0130.0FalseNoneNoneFalseNoneFalse49270.00
3889119149429Nonecode268Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5 Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without controls which shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. - Long point above 6m upto 10m from tapping point to out let via switchPoint555.0555.060.0FalseNoneNoneFalseNoneFalse33300.00
3889120149429Nonecode269Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWGGI fish wire wherever necessary - 19/20 mm dia 2 mm thickm66.066.02250.0FalseNoneNoneFalseNoneFalse148500.00
3889121149429Nonecode270Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWGGI fish wire wherever necessary - 25 mm dia 2 mm thickm78.078.02800.0FalseNoneNoneFalseNoneFalse218400.00
3889122149429Nonecode271Supplying heavy gauge PVC Conduit Pipe.... dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWGGI fish wire run throughout the conduit wherever necessary. - 19/20 mm dia 2 mm thickm68.068.01200.0FalseNoneNoneFalseNoneFalse81600.00
3889123149429Nonecode272Supplying heavy gauge PVC Conduit Pipe.... dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWGGI fish wire run throughout the conduit wherever necessary. - 25 mm dia 2 mm thickm79.079.0650.0FalseNoneNoneFalseNoneFalse51350.00
3889124149429Nonecode273Supplying and fixing PVC/metal conduit Deep junction box - 19/20 mm deep Junction boxEach49.049.0175.0FalseNoneNoneFalseNoneFalse8575.00
3889125149429Nonecode274Supplying and fixing PVC/metal conduit Deep junction box - 25 mm deep Junction boxEach56.056.080.0FalseNoneNoneFalseNoneFalse4480.00
3889126149429Nonecode275Supplying And Fixing Metal Fan Box with Round Hook.No117.0117.0130.0FalseNoneNoneFalseNoneFalse15210.00
3889127149429Nonecode276Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 1-2 WayEach138.0138.012.0FalseNoneNoneFalseNoneFalse1656.00
3889128149429Nonecode277Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 3 WayEach159.0159.015.0FalseNoneNoneFalseNoneFalse2385.00
3889129149429Nonecode278Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 4 - 5 WayEach177.0177.010.0FalseNoneNoneFalseNoneFalse1770.00
3889130149429Nonecode279Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 6 WayEach220.0220.010.0FalseNoneNoneFalseNoneFalse2200.00
3889131149429Nonecode280Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 8 WayEach261.0261.0104.0FalseNoneNoneFalseNoneFalse27144.00
3889132149429Nonecode281Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 10-12 WayEach319.0319.012.0FalseNoneNoneFalseNoneFalse3828.00
3889133149429Nonecode282Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 1-2 ModuleEach137.0137.012.0FalseNoneNoneFalseNoneFalse1644.00
3889134149429Nonecode283Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 3 ModuleEach161.0161.015.0FalseNoneNoneFalseNoneFalse2415.00
3889135149429Nonecode284Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 4 ModuleEach175.0175.010.0FalseNoneNoneFalseNoneFalse1750.00
3889136149429Nonecode285Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 6 ModuleEach234.0234.010.0FalseNoneNoneFalseNoneFalse2340.00
3889137149429Nonecode286Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 8 ModuleEach284.0284.0104.0FalseNoneNoneFalseNoneFalse29536.00
3889138149429Nonecode287Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 10-12 ModuleEach344.0344.012.0FalseNoneNoneFalseNoneFalse4128.00
3889139149429Nonecode288Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 6A One Way SwitchEach102.0102.0552.0FalseNoneNoneFalseNoneFalse56304.00
3889140149429Nonecode289Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 6A Two Way SwitchEach166.0166.012.0FalseNoneNoneFalseNoneFalse1992.00
3889141149429Nonecode290Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 6A Three Way socketEach171.0171.0140.0FalseNoneNoneFalseNoneFalse23940.00
3889142149429Nonecode291Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: Stepped Fan Regulator Two ModuleEach357.0357.0130.0FalseNoneNoneFalseNoneFalse46410.00
3889143149429Nonecode292Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 16A One Way SwitchEach180.0180.06.0FalseNoneNoneFalseNoneFalse1080.00
3889144149429Nonecode293Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 6A Bell PushEach177.0177.01.0FalseNoneNoneFalseNoneFalse177.00
3889145149429Nonecode294Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 32A DP SwitchEach326.0326.04.0FalseNoneNoneFalseNoneFalse1304.00
3889146149429Nonecode295Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 6/16A Universal SocketEach236.0236.010.0FalseNoneNoneFalseNoneFalse2360.00
3889147149429Nonecode296Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: TV/Telephone SocketEach156.0156.04.0FalseNoneNoneFalseNoneFalse624.00
3889148149429Nonecode297Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: RJ45/I.O Outlet Cat-6Each337.0337.05.0FalseNoneNoneFalseNoneFalse1685.00
3889149149429Nonecode298Supplying and fixing one of 230V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. - Ding Dong BellEach246.0246.01.0FalseNoneNoneFalseNoneFalse246.00
3889150149429Nonecode299Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase/3 phase/single door with powder coatedpainting Made out of 14 SWG MS enclosure. - III - Double Door, 12 Way SP & NEach2329.02329.01.0FalseNoneNoneFalseNoneFalse2329.00
3889151149429Nonecode300Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase/3 phase/single door with powder coatedpainting Made out of 14 SWG MS enclosure. - III - Double Door, 6 Way TP & NEach4940.04940.05.0FalseNoneNoneFalseNoneFalse24700.00
3889152149429Nonecode301Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.: 32-40A 4 poleEach5147.05147.05.0FalseNoneNoneFalseNoneFalse25735.00
3889153149429Nonecode302Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.: 63A 4 poleEach5545.05545.01.0FalseNoneNoneFalseNoneFalse5545.00
3889154149429Nonecode303Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.: 6-32A SP MCBEach415.0415.080.0FalseNoneNoneFalseNoneFalse33200.00
3889155149429Nonecode304Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.: 6-32A DP MCBEach739.0739.01.0FalseNoneNoneFalseNoneFalse739.00
3889156149429Nonecode305Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.: 40A TPN MCBEach3044.03044.09.0FalseNoneNoneFalseNoneFalse27396.00
3889157149429Nonecode306Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.: 50-63A TPN MCBEach3088.03088.02.0FalseNoneNoneFalseNoneFalse6176.00
3889158149429Nonecode307Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010: 1.5 mSqmm26.026.03500.0FalseNoneNoneFalseNoneFalse91000.00
3889159149429Nonecode308Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010: 2.5 mSqmm42.042.06020.0FalseNoneNoneFalseNoneFalse252840.00
3889160149429Nonecode309Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010: 4.0 mSqmm63.063.01200.0FalseNoneNoneFalseNoneFalse75600.00
3889161149429Nonecode310Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010: 6.0 mSqmm92.092.0200.0FalseNoneNoneFalseNoneFalse18400.00
3889162149429Nonecode311Supplying of.....feet PVC Batten with integrated LED tube....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 a long with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.: LED light fitting 1 x 4' - 20/22 WEach690.0690.0190.0FalseNoneNoneFalseNoneFalse131100.00
3889163149429Nonecode312Supplying of.....feet PVC Batten with integrated LED tube....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 a long with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.: LED light fitting 1 x 4' - 36/40 WEach1269.01269.030.0FalseNoneNoneFalseNoneFalse38070.00
3889164149429Nonecode313Fixing all types and all capacities of fluorescent/ false ceiling/ spotlight/ CFL/ LED fittings indoor on the wall/ ceiling/ rafters/ girders using 23/ 0.0076" twint wisted PVC insulated wires, required Nos of round blocks and clamps. - On wall/ ceiling / Rafter / GirdersEach122.0122.0220.0FalseNoneNoneFalseNoneFalse26840.00
3889165149429Nonecode314Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than80 lumen per W, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should smaller than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. Theoperating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.: 9W, 6500KEach154.0154.035.0FalseNoneNoneFalseNoneFalse5390.00
3889166149429Nonecode315Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopiesetc, for operation on 230V, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. - 48" Sweep (1200 mm) Regular modelEach2984.02984.0130.0FalseNoneNoneFalseNoneFalse387920.00
3889167149429Nonecode316Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. - Fixing Ceiling FansEach171.0171.0130.0FalseNoneNoneFalseNoneFalse22230.00
3889168149429Nonecode317Supplying of 1440 rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. - 12" Sweep (300 mm)Each2969.02969.020.0FalseNoneNoneFalseNoneFalse59380.00
3889169149429Nonecode318Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5A. Ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire.Each492.0492.020.0FalseNoneNoneFalseNoneFalse9840.00
3889170149429Nonecode319Fabrication suppling and mountuing MS box, made out SWG suitable floor / wall mounting , fully weather proof with privision for better heat disspation , provided with hinged front cover, equipped with temper proof locking arrangements , with suitable size clamps with necessary cable entey pipe with gland and box should be finsihed with 7 tanks treatment with powder coated paint and finllay finished with approved colour etc,.. complete. - 16 SWGSq CM0.430.43337500.0FalseNoneNoneFalseNoneFalse145125.00
3889171149429Nonecode320Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.: FOUR Pole 100 A 25 kAEach8487.08487.01.0FalseNoneNoneFalseNoneFalse8487.00
3889172149429Nonecode321Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.: FOUR Pole 160 A 25 kAEach13447.013447.02.0FalseNoneNoneFalseNoneFalse26894.00
3889173149429Nonecode322Supplying.........A rated 3 phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ FRP/ DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete: 250 A 4 x 30 x 10 mm Aluminium Stripsm3435.03435.028.0FalseNoneNoneFalseNoneFalse96180.00
3889174149429Nonecode323Supply and fixing of angle iron frame work fabricated out of ms angle iron,.. With bolts , washer, etc, and painted with 2 coat of red oxide and then two coats of approved paint. - 50 x 100 x 50 x 6 mm C channelm756.0756.012.0FalseNoneNoneFalseNoneFalse9072.00
3889175149429Nonecode324Supplying and fixing of Shunt trip suitable for MCCB.CBCTEach1703.01703.01.0FalseNoneNoneFalseNoneFalse1703.00
3889176149429Nonecode325Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each452.0452.01.0FalseNoneNoneFalseNoneFalse452.00
3889177149429Nonecode326Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each515.0515.06.0FalseNoneNoneFalseNoneFalse3090.00
3889178149429Nonecode327Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50Hz AC with latest micro controller based, digital read out of percentage leakage current, programmable delay/ auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each9255.09255.01.0FalseNoneNoneFalseNoneFalse9255.00
3889179149429Nonecode328Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm allround with alterate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.GI pipe earthing make-TATA/GENITH,JINDAL.No4256.04256.08.0FalseNoneNoneFalseNoneFalse34048.00
3889180149429Nonecode329Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.: 25 x 3 mm GI stripm82.082.0150.0FalseNoneNoneFalseNoneFalse12300.00
3889181149429Nonecode330Supplying and fixing of LED Bulk head of 10W with IP 65 protection and IK08 impact resistance suitable for surface and wall mounting applications.Each842.0842.05.0FalseNoneNoneFalseNoneFalse4210.00
3889182149429Nonecode331Supplying of on Auto load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution): 200 AEach15249.015249.01.0FalseNoneNoneFalseNoneFalse15249.00
3889183149429Nonecode332Fixing of..... A TPST / change overs witch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling. - 100A to 250A TPSTEach447.0447.01.0FalseNoneNoneFalseNoneFalse447.00
3889184149429Nonecode3331.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975: 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)Km373215.0373215.00.03FalseNoneNoneFalseNoneFalse11196.450
3889185149429Nonecode3341.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975: 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm)Km139549.0139549.00.03FalseNoneNoneFalseNoneFalse4186.470
3889186149429Nonecode3351.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975: 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)Km141842.0141842.00.1FalseNoneNoneFalseNoneFalse14184.20
3889187149429Nonecode336Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable - 3.5 x 70/95/120 SqmmSet382.0382.06.0FalseNoneNoneFalseNoneFalse2292.00
3889188149429Nonecode337Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable - Up to 4C x 50 SqmmSet324.0324.011.0FalseNoneNoneFalseNoneFalse3564.00
3889189149429Nonecode338Aluminium End Terminal (Lug) - 95 SqmmNo15.015.024.0FalseNoneNoneFalseNoneFalse360.00
3889190149429Nonecode339Aluminium End Terminal (Lug) - 25 SqmmNo3.03.016.0FalseNoneNoneFalseNoneFalse48.00
3889191149429Nonecode340Aluminium End Terminal (Lug) - 16 SqmmNo2.02.016.0FalseNoneNoneFalseNoneFalse32.00
3889192149429Nonecode341Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable - 35 to 95 SqmmKm31139.031139.00.03FalseNoneNoneFalseNoneFalse934.170
3889193149429Nonecode342Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable - 2.5 to 25 SqmmKm20886.020886.00.1FalseNoneNoneFalseNoneFalse2088.60
3889194149429Nonecode343Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. - In all kinds of soils. Depth upto 1.50mm484.0484.020.0FalseNoneNoneFalseNoneFalse9680.00
3889195149429Nonecode344Fabricating, supplying and erection of...ms long hot dip Galvanized Octagonal hot dip Pole with BSEN10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to with stand the wind speed of 47 m/s for.......m Pole in single section and single joint welded as per IS 9595 / IS 10178 AWS having dimensions bottom.....mm, top....mm with 3mm thick, suitable base plate and 4 Nos of..... long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65 micron as per ASTM- A 123 and 153 etc.,(excluding foundation) as per drawing appended. - 9 m - Top 70 mm and Bottom 155 mm diaEach19500.019500.04.0FalseNoneNoneFalseNoneFalse78000.00
3889196149429Nonecode345Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4" dia telescopic M.S. pipe, with 2" dia 1.5m long M.S. Bracket and are welded with suitable angle, using 6mm thick M.S.sheet, grip bolts & nuts, as required, suitable for 9 to 12ms. M.S. tubular pole, with necessary two coats of painting, with all other accessories. - Single bracket 1.5 m. LengthNo1461.01461.04.0FalseNoneNoneFalseNoneFalse5844.00
3889197149429Nonecode346Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencygreater than130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. - LED Streetlight 90 WEach8860.08860.04.0FalseNoneNoneFalseNoneFalse35440.00
3889198149429Nonecode347Fixing halogen / metal halide / SVL / IL / LED flood light fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each162.0162.04.0FalseNoneNoneFalseNoneFalse648.00
3889199149429Nonecode348Supplying and drawing Flexible Multi core Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 - 3C x 1.5 mm2m72.072.048.0FalseNoneNoneFalseNoneFalse3456.00
3889200149429Nonecode349Supplying and drawing UTP-CAT 6E LAN cable.m38.038.0549.0FalseNoneNoneFalseNoneFalse20862.00
3889201149429Nonecode350Supplying & Fixing of ... ms Cat 6 Patch Cable - 2mEach257.0257.06.0FalseNoneNoneFalseNoneFalse1542.00
3889202149429Nonecode351Supplying & Fixing of switch mounting rack with power manager & Cable manager. - 12U with 450mm depthEach8835.08835.01.0FalseNoneNoneFalseNoneFalse8835.00
3889203149429Nonecode352Supplying & Fixing of Power stripEach1457.01457.01.0FalseNoneNoneFalseNoneFalse1457.00
3889204149429Nonecode353Supplying fixing of Network Switches: 8 port 10/100 SwitchEach1050.01050.01.0FalseNoneNoneFalseNoneFalse1050.00
3889205149429Nonecode354Supply Installation Testing 32Channel Digital Video Recorder with Video Input, Real Time recording DVR & AV compatible, improved clarity for better recognition, longer recording time, extended range of features, multiple interfacing options, image quality with all required accessories including all labour charges etc completeEach38000.038000.01.0FalseNoneNoneFalseNoneFalse38000.00
3889206149429Nonecode355Supply & Installation of indoor fixed dome camera with 720TVL ,1/3" Super HAD CCD colour, 3.6mm fixed lens,2 mega picsels, Day & Night IR LED & supports 15Mtr distance, enhanced picture quality, reliability mounted on ceilings or walls with all required accessories including all labour charges etc complete.Each9750.09750.010.0FalseNoneNoneFalseNoneFalse97500.00
3889207149429Nonecode356Supply & Installation of Outdoor bullet camera with 650TVL,Day & Night IR LED supports 60 Mtr distance, 4 mega piicsels , HD, enhanced picture quality, reliability mounted on ceiling or walls,with IP55 Enclosure with all required steel supports ,accessories including all labour charges etc complete.Each16247.016247.04.0FalseNoneNoneFalseNoneFalse64988.00
3889208149429Nonecode357Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete.Each5288.05288.01.0FalseNoneNoneFalseNoneFalse5288.00
3889209149429Nonecode358Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 0 to 50 Mtrsm309.0309.050.0FalseNoneNoneFalseNoneFalse15450.00
3889210149429Nonecode359Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 50 to 100 Mtrsm387.0387.050.0FalseNoneNoneFalseNoneFalse19350.00
3889211149429Nonecode360Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 100 to 150 Mtrsm412.0412.050.0FalseNoneNoneFalseNoneFalse20600.00
3889212149429Nonecode361Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 150 to 200 Mtrsm478.0478.050.0FalseNoneNoneFalseNoneFalse23900.00
3889213149429Nonecode362Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 200 to 250 Mtrsm560.0560.050.0FalseNoneNoneFalseNoneFalse28000.00
3889214149429Nonecode363Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 250 to 300 Mtrsm593.0593.050.0FalseNoneNoneFalseNoneFalse29650.00
3889215149429Nonecode364Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m1990.991990.9930.0FalseNoneNoneFalseNoneFalse59729.70
3889216149429Nonecode365Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge.Each164.0164.01.0FalseNoneNoneFalseNoneFalse164.00
3889217149429Nonecode366Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsEach150.0150.02.0FalseNoneNoneFalseNoneFalse300.00
3889218149429Nonecode367Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. - 7.50 HP - 135 LPM @ 140 m = 12 STG Outlet Dia - 2.00"Each36620.036620.01.0FalseNoneNoneFalseNoneFalse36620.00
3889219149429Nonecode368Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover). - 50 mmEach3050.03050.050.0FalseNoneNoneFalseNoneFalse152500.00
3889220149429Nonecode369Labour charges for Erection of new / repaired submersible pump set along with GI pipes (32mm / 50mm), cable (New submersible pump set if required will be supplied by the department free of cost and released pump set should be handed over to department) including transportation (Each length = 6 m)Job187.0187.050.0FalseNoneNoneFalseNoneFalse9350.00
3889221149429Nonecode370Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. - 1x3x6 Sqm.m185.0185.0330.0FalseNoneNoneFalseNoneFalse61050.00
3889222149429Nonecode371Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments. - Size 50 mmEach1250.01250.01.0FalseNoneNoneFalseNoneFalse1250.00
3889223149429Nonecode372Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. - for outdoor - 6 to 15 HP pumpsEach17500.017500.01.0FalseNoneNoneFalseNoneFalse17500.00
3889224149429Nonecode3731.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - 16 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm)Km88418.088418.00.3FalseNoneNoneFalseNoneFalse26525.40
3889225149429Nonecode374Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. - Medium Duty GI pipe of 65mm diam719.0719.010.0FalseNoneNoneFalseNoneFalse7190.00
3889226149429Nonecode375Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - UG SUMPSqm312.0312.075.1FalseNoneNoneFalseNoneFalse23431.20
3889227149429Nonecode376Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel reinforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)Sqm615.0615.077.0FalseNoneNoneFalseNoneFalse47355.00
3889228149429Nonecode377Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.Each1962.01962.02.0FalseNoneNoneFalseNoneFalse3924.00
3889229149429Nonecode378Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. - Upto 3 HP pumpsEach6500.06500.01.0FalseNoneNoneFalseNoneFalse6500.00
3889230149429Nonecode379Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. - 3.00 HP/2.2KW - 9 STGEach20113.020113.01.0FalseNoneNoneFalseNoneFalse20113.00
3889231149429Nonecode380Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. - 1x3x6 Sqm.m185.0185.030.0FalseNoneNoneFalseNoneFalse5550.00
3889232149429Nonecode381Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1002.01002.012.56FalseNoneNoneFalseNoneFalse12585.120
3889233149429Nonecode382Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineerin- charge.Cum1186.01186.012.56FalseNoneNoneFalseNoneFalse14896.160
3889234149429Nonecode383Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1192.01192.012.56FalseNoneNoneFalseNoneFalse14971.520
3889235149429Nonecode384Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm928.0928.05.76FalseNoneNoneFalseNoneFalse5345.280
3889236149429Nonecode385Design, supplying, erecting testing and commissioning of - Passenger/ Bed - cum - passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V3 phase 50 cycles AC supply, powder coated/ Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED carillumination, emergency light, inter comand fan as desired by the user, central opening/ side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fire mandrive, SS hand rails inside car, full length infra red curtain in car door, automatic rescue device with batteries, voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665 /2016 (with latest amendments) part/ section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressures witch, manual change over for doors during emergency, ARD of 10 times with sufficient battery backup and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. - D With Out Machine Room-SS Finish - Capacity of 13 Passengers - 5 StopsJob1884540.141884540.141.0FalseNoneNoneFalseNoneFalse1884540.140
3889237149429Nonecode386Waste water Treatment by Bio Sewage Treatment Plant (Bio STP) onsite construction [25 KLD and 50 KLD ]: Providing, installation and commissioning of anaerobic Bio Sewage Treatment Plant (Bio STP) for black water with all necessary accessories such as pre- filter, pipes for the onsite constructed ABD tank as per the prescribed specification, according to the capacity, with a baffle wall to control the flow of water and to increase the retention time in the RCC ABD Tank. It includes an internal matrix for enhanced growth of bacteria, rising and falling pipes. For grey water, pre - filter, oil skimmer is provided along with an aerator. Post filter such as sand and carbon filter are also included as per the enclosed detailed technical specification attached as Annexure-2, including cost of material, loading and unloading and as directed by the engineer in charge etc., complete, including annual maintenance of the system for 5 years. Note: 1. Above rates mentioned are for the preparation of estimate purpose only. 2. All items are of ISI standards. 3. After commissioning of plant necessary testing to be done for the Satisfaction of the Engineer in charge. 4. Design drawing of the system suitable for erection 50 KLD is given in figure for reference. - 50 KLDEach2545000.02545000.01.0FalseNoneNoneFalseNoneFalse2545000.00
3889238149429Nonecode387Cost of Haulage Excluding Loading and Unloading - Case-1 : Surfaced Road - a Taking output 10 t load and lead 10 km = 100 kmKm15.3615.36150.0FalseNoneNoneFalseNoneFalse2304.00
3889239149429Nonecode388Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) - 600 x 300 x 100 mm sizem266.0266.0250.0FalseNoneNoneFalseNoneFalse66500.00
3889240149429Nonecode389Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.Each61060.061060.05.0FalseNoneNoneFalseNoneFalse305300.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17250183070000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17250183070000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17250183070000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17250183070000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17250183070000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17250183140000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17250183180000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17250183220000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17250183250000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17250183280000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17250183350000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17250183370000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17250183410000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17250183450000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17250183480000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17250183520000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17250183550000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17250183580000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17250183630000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17250183670000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1725023858000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone